KNX Database
Dinuy PE KNT 002 Actuator 1ch Blind / 2ch Switch - 4 Inputs

Actuator 1ch Blind / 2ch Switch - 4 Inputs PE KNT 002

Dinuy · Order number PE KNT 002 · KNX-TP Devices › Actuators › Switch and Shutter/Blind Actuators

Download .knxprod DINUY_PEKNT002 0.0 · 193 KB

Product

ManufacturerDinuy
Product nameActuator 1ch Blind / 2ch Switch - 4 Inputs
Order numberPE KNT 002
HardwareActuator 2ch Switch/blind- 4input ch
MediumTwisted Pair
Bus current (mA)10
Rail mountedNo
RegistrationCertified · 2019-02-05
Languageses-ES, en-US
Catalog entryM-009A_H-009APEKNT002200918-0_HP-2003-00-5F61_CI-PE.20KNT.20002-1
Fingerprint5F61
SHA-256b2417f717ebf97fa360eac54d15171086a556ab5ed932d231219510e95265bbd
First seen2026-11-25
Markets68 markets

Application program: DINUY_PEKNT002 0.0

Application number$2003
Version0.0
Mask versionMV-07B0 (System B)
KNX Data SecureNo
Minimum ETS version5.0
Parameters649
Group objects341
Group objects (341)
NoNameFunctionSizeDPTFlags
1[In1] Disable Input1 = Disable, 0 = Enable1 Bit1.3 enableCW
1[In1] Disable Temperature Functionality1 = Disable, 0 = Enable1 Bit1.3 enableCW
2[In1] Switch1 = On, 0 = Off1 Bit1.1 switchCT
2[In1] Stop / Step0 = Step Up, 1 = Step Down1 Bit1.7 stepCT
2[In1] Bit value on pressBit value1 Bit1.11 stateCT
2[In1] 2 Bits value on press2 Bits value2 Bit2.1 switch controlCT
2[In1] Scene Control 8 BitsScene Control1 Byte18.1 scene controlCT
2[In1] 2 Bytes signed value on press2 Bytes signed value2 Bytes8.1 pulses differenceCT
2[In1] 2 Bytes floating value on press2 Bytes floating value2 Bytes9.1 temperature (°C)CT
2[In1] Byte value on pressByte value1 Byte5.10 counter pulses (0..255)CT
2[In1] 4 Bytes value on press4 Bytes value4 Bytes12.1 counter pulses (unsigned)CT
2[In1] Temperature value OutputTemperature value2 Bytes9.1 temperature (°C)CT
2[In1] Counter direction0 = Up, 1 = Down1 Bit1.8 up/downCW
2[In1] Scene 1 Bit0 = Scene 1, 1 = Scene 21 Bit1.11 stateCT
2[In1] 2 Bytes value on press2 Bytes value2 Bytes7.1 pulsesCT
3[In1] Long Switch1 = On, 0 = Off1 Bit1.1 switchCT
3[In1] Reset Counter0 = No action, 1 = Reset1 Bit1.15 resetCW
3[In1] Switch 21 = On, 0 = Off1 Bit1.1 switchCT
3[In1] Save Scene0 = No action, 1 = Save Scene 1 Bit1.3 enableCW
3[In1] 4 Bytes value on Long press4 Bytes value4 Bytes12.1 counter pulses (unsigned)CT
3[In1] 2 Bytes floating value on Long press2 Bytes floating value2 Bytes9.1 temperature (°C)CT
3[In1] 2 Bytes signed value on Long press2 Bytes signed value2 Bytes8.1 pulses differenceCT
3[In1] Bit value on Long pressBit value1 Bit1.11 stateCT
3[In1] 2 Bits value on Long press2 Bits value2 Bit2.1 switch controlCT
3[In1] Sensor not connected0 = Sensor Ok, 1 = Sensor not connected1 Bit1.11 stateCT
3[In1] Byte value on Long pressByte value1 Byte5.10 counter pulses (0..255)CT
3[In1] 2 Bytes value on Long press2 Bytes value2 Bytes7.1 pulsesCT
3[In1] Dimming ControlDimming Control4 Bit3.7 dimming controlCT
3[In1] Move0 = Up, 1 = Down1 Bit1.8 up/downCT
4[In1] Switch Feedback1 = On, 0 = Off1 Bit1.1 switchCW
4[In1] Request Counter1 = Trigger1 Bit1.17 triggerCW
4[In1] Over-Heating Output1 = Over-Heating, 0 = No Over-Heating1 Bit1.5 alarmCT
4[In1] Switch 31 = On, 0 = Off1 Bit1.1 switchCT
5[In1] Long Switch Feedback1 = On, 0 = Off1 Bit1.1 switchCW
5[In1] Counter 32 BitsCounter (0-4.294.967.295)4 Bytes13.1 counter pulses (signed)CT
5[In1] Over-Cooling Output1 = Over-Cooling, 0 = No Over-Cooling1 Bit1.5 alarmCT
5[In1] Counter 8 BitsCounter (0-255)1 Byte5.10 counter pulses (0..255)CT
5[In1] Counter 16 BitsCounter (0-65535)2 Bytes7.1 pulsesCT
5[In1] Switch 41 = On, 0 = Off1 Bit1.1 switchCT
6[In1] Switch 51 = On, 0 = Off1 Bit1.1 switchCT
7[In1] Increase/Decrease0 = Increase, 1 = Decrease1 Bit1.8 up/downCW
7[In1] Save Scene0 = Scene 1, 1 = Scene 21 Bit1.3 enableCT
8[In2] Disable Input1 = Disable, 0 = Enable1 Bit1.3 enableCW
8[In2] Disable Temperature Functionality1 = Disable, 0 = Enable1 Bit1.3 enableCW
9[In2] Switch1 = On, 0 = Off1 Bit1.1 switchCT
9[In2] 4 Bytes value on press4 Bytes value4 Bytes12.1 counter pulses (unsigned)CT
9[In2] 2 Bytes signed value on press2 Bytes signed value2 Bytes8.1 pulses differenceCT
9[In2] Temperature value OutputTemperature value2 Bytes9.1 temperature (°C)CT
9[In2] Stop / Step0 = Step Up, 1 = Step Down1 Bit1.7 stepCT
9[In2] 2 Bits value on press2 Bits value2 Bit2.1 switch controlCT
9[In2] 2 Bytes value on press2 Bytes value2 Bytes7.1 pulsesCT
9[In2] Bit value on pressBit value1 Bit1.11 stateCT
9[In2] Counter direction0 = Up, 1 = Down1 Bit1.8 up/downCW
9[In2] Byte value on pressByte value1 Byte5.10 counter pulses (0..255)CT
9[In2] 2 Bytes floating value on press2 Bytes floating value2 Bytes9.1 temperature (°C)CT
9[In2] Scene 1 Bit0 = Scene 1, 1 = Scene 21 Bit1.11 stateCT
9[In2] Scene Control 8 BitsScene Control1 Byte18.1 scene controlCT
10[In2] Long Switch1 = On, 0 = Off1 Bit1.1 switchCT
10[In2] Save Scene0 = No action, 1 = Save Scene 1 Bit1.3 enableCW
10[In2] Switch 21 = On, 0 = Off1 Bit1.1 switchCT
10[In2] Bit value on Long pressBit value1 Bit1.11 stateCT
10[In2] Reset Counter0 = No action, 1 = Reset1 Bit1.15 resetCW
10[In2] Move0 = Up, 1 = Down1 Bit1.8 up/downCT
10[In2] 2 Bytes floating value on Long press2 Bytes floating value2 Bytes9.1 temperature (°C)CT
10[In2] 2 Bytes signed value on Long press2 Bytes signed value2 Bytes8.1 pulses differenceCT
10[In2] 4 Bytes value on Long press4 Bytes value4 Bytes12.1 counter pulses (unsigned)CT
10[In2] 2 Bits value on Long press2 Bits value2 Bit2.1 switch controlCT
10[In2] Sensor not connected Output0 = Sensor Ok, 1 = Sensor not connected1 Bit1.11 stateCT
10[In2] Byte value on Long pressByte value1 Byte5.10 counter pulses (0..255)CT
10[In2] 2 Bytes value on Long press2 Bytes value2 Bytes7.1 pulsesCT
10[In2] Dimming ControlDimming Control4 Bit3.7 dimming controlCT
11[In2] Switch Feedback1 = On, 0 = Off1 Bit1.1 switchCW
11[In2] Switch 31 = On, 0 = Off1 Bit1.1 switchCT
11[In2] Request Counter1 = Trigger1 Bit1.17 triggerCW
11[In2] Over-Heating Output1 = Over-Heating, 0 = No Over-Heating1 Bit1.5 alarmCT
12[In2] Long Switch Feeback1 = On, 0 = Off1 Bit1.1 switchCW
12[In2] Counter 16 BitsCounter (0-65535)2 Bytes7.1 pulsesCT
12[In2] Switch 41 = On, 0 = Off1 Bit1.1 switchCT
12[In2] Over-Cooling Output1 = Over-Cooling, 0 = No Over-Cooling1 Bit1.5 alarmCT
12[In2] Counter 8 BitsCounter (0-255)1 Byte5.10 counter pulses (0..255)CT
12[In2] Counter 32 BitsCounter (0-4.294.967.295)4 Bytes13.1 counter pulses (signed)CT
13[In2] Switch 51 = On, 0 = Off1 Bit1.1 switchCT
14[In2] Save Scene0 = Scene 1, 1 = Scene 21 Bit1.3 enableCT
14[In2] Increase/Decrease0 = Increase, 1 = Decrease1 Bit1.8 up/downCW
15[In3] Disable Input1 = Disable, 0 = Enable1 Bit1.3 enableCW
15[In3] Disable Temperature Functionality1 = Disable, 0 = Enable1 Bit1.3 enableCW
16[In3] Switch1 = On, 0 = Off1 Bit1.1 switchCT
16[In3] Scene Control 8 BitsScene Control1 Byte18.1 scene controlCT
16[In3] Temperature value OutputTemperature value2 Bytes9.1 temperature (°C)CT
16[In3] 2 Bytes floating value on press2 Bytes floating value2 Bytes9.1 temperature (°C)CT
16[In3] Byte value on pressByte value1 Byte5.10 counter pulses (0..255)CT
16[In3] Counter direction0 = Up, 1 = Down1 Bit1.8 up/downCW
16[In3] Bit value on pressBit value1 Bit1.11 stateCT
16[In3] 2 Bytes value on press2 Bytes value2 Bytes7.1 pulsesCT
16[In3] 2 Bits value on press2 Bits value2 Bit2.1 switch controlT
16[In3] Stop / Step0 = Step Up, 1 = Step Down1 Bit1.7 stepCT
16[In3] 2 Bytes signed value on press2 Bytes signed value2 Bytes8.1 pulses differenceCT
16[In3] Scene 1 Bit0 = Scene 1, 1 = Scene 21 Bit1.11 stateCT
16[In3] 4 Bytes value on press4 Bytes value4 Bytes12.1 counter pulses (unsigned)CT
17[In3] 2 Bytes floating value on Long press2 Bytes floating value2 Bytes9.1 temperature (°C)CT
17[In3] Switch 21 = On, 0 = Off1 Bit1.1 switchCT
17[In3] 2 Bytes signed value on Long press2 Bytes signed value2 Bytes8.1 pulses differenceCT
17[In3] Save Scene0 = No action, 1 = Save Scene 1 Bit1.3 enableCW
17[In3] Move0 = Up, 1 = Down1 Bit1.8 up/downCT
17[In3] Reset Counter0 = No action, 1 = Reset1 Bit1.15 resetCW
17[In3] 2 Bits value on Long press2 Bits value2 Bit2.1 switch controlCT
17[In3] Sensor not connected Output0 = Sensor Ok, 1 = Sensor not connected1 Bit1.11 stateCT
17[In3] Byte value on Long pressByte value1 Byte5.10 counter pulses (0..255)CT
17[In3] 2 Bytes value on Long press2 Bytes value2 Bytes7.1 pulsesCT
17[In3] Dimming ControlDimming Control4 Bit3.7 dimming controlCT
17[In3] Switch Long1 = On, 0 = Off1 Bit1.1 switchCT
17[In3] Bit value on Long pressBit value1 Bit1.11 stateCT
17[In3] 4 Bytes value on Long press4 Bytes value4 Bytes12.1 counter pulses (unsigned)CT
18[In3] Request Counter1 = Trigger1 Bit1.17 triggerCW
18[In3] Over-Heating Output1 = Over-Heating, 0 = No Over-Heating1 Bit1.5 alarmCT
18[In3] Switch 31 = On, 0 = Off1 Bit1.1 switchCT
18[In3] Switch Feedback1 = On, 0 = Off1 Bit1.1 switchCW
19[In3] Switch 41 = On, 0 = Off1 Bit1.1 switchCT
19[In3] Over-Cooling Output1 = Over-Cooling, 0 = No Over-Cooling1 Bit1.5 alarmCT
19[In3] Counter 8 BitsCounter (0-255)1 Byte5.10 counter pulses (0..255)CT
19[In3] Counter 32 BitsCounter (0-4.294.967.295)4 Bytes13.1 counter pulses (signed)CT
19[In3] Long Switch Feedback1 = On, 0 = Off1 Bit1.1 switchCW
19[In3] Counter 16 BitsCounter (0-65535)2 Bytes7.1 pulsesCT
20[In3] Switch 51 = On, 0 = Off1 Bit1.1 switchCT
21[In3] Increase/Decrease0 = Increase, 1 = Decrease1 Bit1.8 up/downCW
21[In3] Save Scene0 = Scene 1, 1 = Scene 21 Bit1.3 enableCT
22[In4] Disable Input1 = Disable, 0 = Enable1 Bit1.3 enableCW
22[In4] Disable Temperature Functionality1 = Disable, 0 = Enable1 Bit1.3 enableCW
23[In4] Switch1 = On, 0 = Off1 Bit1.1 switchCT
23[In4] 2 Bytes floating value on press2 Bytes floating value2 Bytes9.1 temperature (°C)CT
23[In4] Scene 1 Bit0 = Scene 1, 1 = Scene 21 Bit1.11 stateCT
23[In4] Counter direction0 = Up, 1 = Down1 Bit1.8 up/downCW
23[In4] 4 Bytes value on press4 Bytes value4 Bytes12.1 counter pulses (unsigned)CT
23[In4] Temperature value OutputTemperature value2 Bytes9.1 temperature (°C)CT
23[In4] 2 Bytes value on press2 Bytes value2 Bytes7.1 pulsesCT
23[In4] 2 Bits value on press2 Bits value2 Bit2.1 switch controlCT
23[In4] Stop / Step0 = Step Up, 1 = Step Down1 Bit1.7 stepCT
23[In4] 2 Bytes signed value on press2 Bytes signed value2 Bytes8.1 pulses differenceCT
23[In4] Bit value on pressBit value1 Bit1.11 stateCT
23[In4] Byte value on pressByte value1 Byte5.10 counter pulses (0..255)CT
23[In4] Scene Control 8 BitsScene Control1 Byte18.1 scene controlCT
24[In4] 4 Bytes value on Long press4 Bytes value4 Bytes12.1 counter pulses (unsigned)CT
24[In4] 2 Bytes floating value on Long press2 Bytes floating value2 Bytes9.1 temperature (°C)CT
24[In4] Move0 = Up, 1 = Down1 Bit1.8 up/downCT
24[In4] 2 Bytes signed value on Long press2 Bytes signed value2 Bytes8.1 pulses differenceCT
24[In4] Reset Counter0 = No action, 1 = Reset1 Bit1.15 resetCW
24[In4] 2 Bits value on Long press2 Bits value2 Bit2.1 switch controlCT
24[In4] Sensor not connected Output0 = Sensor Ok, 1 = Sensor not connected1 Bit1.11 stateCT
24[In4] Byte value on Long pressByte value1 Byte5.10 counter pulses (0..255)CT
24[In4] 2 Bytes value on Long press2 Bytes value2 Bytes7.1 pulsesCT
24[In4] Dimming ControlDimming Control4 Bit3.7 dimming controlCT
24[In4] Long Switch1 = On, 0 = Off1 Bit1.1 switchCT
24[In4] Bit value on Long pressBit value1 Bit1.11 stateCT
24[In4] Switch 21 = On, 0 = Off1 Bit1.1 switchCT
24[In4] Save Scene0 = No action, 1 = Save Scene 1 Bit1.3 enableCW
25[In4] Switch 31 = On, 0 = Off1 Bit1.1 switchCT
25[In4] Switch Feedback1 = On, 0 = Off1 Bit1.1 switchCW
25[In4] Over-Heating Output1 = Over-Heating, 0 = No Over-Heating1 Bit1.5 alarmCT
25[In4] Request Counter1 = Trigger1 Bit1.17 triggerCW
26[In4] Counter 32 BitsCounter (0-4.294.967.295)4 Bytes13.1 counter pulses (signed)CT
26[In4] Over-Cooling Output1 = Over-Cooling, 0 = No Over-Cooling1 Bit1.5 alarmCT
26[In4] Counter 8 BitsCounter (0-255)1 Byte5.10 counter pulses (0..255)CT
26[In4] Long Switch Feedback1 = On, 0 = Off1 Bit1.1 switchCW
26[In4] Switch 41 = On, 0 = Off1 Bit1.1 switchCT
26[In4] Counter 16 BitsCounter (0-65535)2 Bytes7.1 pulsesCT
27[In4] Switch 51 = On, 0 = Off1 Bit1.1 switchCT
28[In4] Save Scene0 = Scene 1, 1 = Scene 21 Bit1.3 enableCT
28[In4] Increase/Decrease0 = Increase, 1 = Decrease1 Bit1.8 up/downCW
30[Out1] Switch Feedback1 = On, 0 = Off1 Bit1.1 switchCT
31[Out1] Switch On/Off1 = On, 0 = Off1 Bit1.1 switchCW
32[Out1] Forced positioning 1 Bit1 = Forced, 0 = Not Forced1 Bit1.1 switchCW
32[Out1] Forced positioning 2 Bits2 Bits value2 Bit2.1 switch controlCW
34[Out1] Change Threshold value1 Byte value1 Byte5.10 counter pulses (0..255)CW
34[Out1] Change Threshold value2 Bytes value2 Bytes7.1 pulsesCW
35[Out1] Threshold Input1 Byte value1 Byte5.10 counter pulses (0..255)CW
35[Out1] Threshold Input2 Bytes value2 Bytes7.1 pulsesCW
37[Out1] Logical connection 11 = True, 0 = False1 Bit1.2 booleanCW
38[Out1] Logical connection 21 = True, 0 = False1 Bit1.2 booleanCW
39[Out1] Scene Scene Control1 Byte18.1 scene controlCW
40[Out1] Set Preset 1/2Telegram 0 --> Set Preset 1, Telegram 1 --> Set Preset 21 Bit1.1 switchCW
41[Out1] Call Preset 1/2Telegram 0 --> Call Preset 1, Telegram 1 --> Call Preset 21 Bit1.3 enableCW
42[Out1] Time Switch1 = Timer On1 Bit1.10 start/stopCW
43[Out1] Staircase lighting Pre-warning1 = Pre-warning, 0 = No Pre-warning1 Bit1.1 switchCT
44[Out1] Length of staircase light (sec)2 Bytes value2 Bytes7.5 time (s)CW
45[Out1] Permanent ON1 = On, 0 = Off1 Bit1.1 switchCW
46[Out1] Disable Time Function1 = Disable, 0 = Enable1 Bit1.3 enableCW
50[Out2] Switch Feedback1 = On, 0 = Off1 Bit1.1 switchCT
51[Out2] Switch On/Off1 = On, 0 = Off1 Bit1.1 switchCW
52[Out2] Forced positioning 1-Bit1 = Forced, 0 = Not Forced1 Bit1.1 switchCW
52[Out2] Forced positioning 2 Bits2 Bits value2 Bit2.1 switch controlCW
54[Out2] Change Threshold value1 Byte value1 Byte5.10 counter pulses (0..255)CW
54[Out2] Change Threshold value2 Bytes value2 Bytes7.1 pulsesCW
55[Out2] Threshold Input1 Byte value1 Byte5.10 counter pulses (0..255)CW
55[Out2] Threshold Input2 Bytes value2 Bytes7.1 pulsesCW
57[Out2] Logical connection 11 = True, 0 = False1 Bit1.2 booleanCW
58[Out2] Logical connection 21 = True, 0 = False1 Bit1.2 booleanCW
59[Out2] Scene Scene Control1 Byte18.1 scene controlCW
60[Out2] Set Preset 1/2Telegram 0 --> Set Preset 1, Telegram 1 --> Set Preset 21 Bit1.1 switchCW
61[Out2] Call Preset 1/2Telegram 0 --> Call Preset 1, Telegram 1 --> Call Preset 21 Bit1.3 enableCW
62[Out2] Time Switch1 = Timer On1 Bit1.10 start/stopCW
63[Out2] Stairca lighting Pre-warning1 = Pre-warning, 0 = No pre-warning1 Bit1.1 switchCT
64[Out2] Length of staircase light (sec)2 Bytes value2 Bytes7.5 time (s)CW
65[Out2] Permanent ON1 = On, 0 = Off1 Bit1.1 switchCW
66[Out2] Disable Time Function1 = Disable, 0 = Enable1 Bit1.3 enableCW
70[Out] Blind Move Up/Down0 = Up, 1 = Down1 Bit1.8 up/downCW
70[Out] Roller Move Up/Down0 = Up, 1 = Down1 Bit1.8 up/downCW
70[Out] Louver Move Up/Down0 = Up, 1 = Down1 Bit1.8 up/downCW
71[Out] Blind Stop / Step Up/Down0 = Step Up, 1 = Step Down1 Bit1.7 stepCW
71[Out] Roller Stop / Step Up/Down0 = Step Up, 1 = Step Down1 Bit1.7 stepCW
71[Out] Louver Stop / Step Up/Down0 = Step Up, 1 = Step Down1 Bit1.7 stepCW
72[Out] Forced Input2 Bits control2 Bit2.1 switch controlCW
73[Out] Wind Alarm 11 = Alarm, 0 = No Alarm1 Bit1.5 alarmCW
74[Out] Wind Alarm 21 = Alarm, 0 = No Alarm1 Bit1.5 alarmCW
75[Out] Wind Alarm 31 = Alarm, 0 = No Alarm1 Bit1.5 alarmCW
76[Out] Rain Alarm 1 = Alarm, 0 = No Alarm1 Bit1.5 alarmCW
77[Out] Frost Alarm1 = Alarm, 0 = No Alarm1 Bit1.5 alarmCW
78[Out] Scene InputScene Control1 Byte18.1 scene controlCW
79[Out] Movement Feedback0 = Up, 1 = Down1 Bit1.8 up/downCT
80[Out] Blind position Input0h = 0%, 80h = 50%, FFh = 100%1 Byte5.1 percentage (0..100%)CW
80[Out] Louver position Input0h = 0%, 80h = 50%, FFh = 100%1 Byte5.1 percentage (0..100%)CW
80[Out] Roller position Input0h = 0%, 80h = 50%, FFh = 100%1 Byte5.1 percentage (0..100%)CW
81[Out] Slats position Input0h = 0%, 80h = 50%, FFh = 100%1 Byte5.1 percentage (0..100%)CW
82[Out] Blind position Feedback0h = 0%, 80h = 50%, FFh = 100%1 Byte5.1 percentage (0..100%)CT
82[Out] Roller position Feedback0h = 0%, 80h = 50%, FFh = 100%1 Byte5.1 percentage (0..100%)CT
82[Out] Louver position Feedback0h = 0%, 80h = 50%, FFh = 100%1 Byte5.1 percentage (0..100%)CT
83[Out] Slats position Feedback0h = 0%, 80h = 50%, FFh = 100%1 Byte5.1 percentage (0..100%)CT
84[Out] Lux level InputLux value2 Bytes9.4 lux (Lux)CW
84[Out] Sun Protection Input1 = On, 0 = Off1 Bit1.1 switchCW
85[Out] Sun Protection position Input0h = 0%, 80h = 50%, FFh = 100%1 Byte5.1 percentage (0..100%)CW
90[T1] On/Off Feedback1 = On; 0 = Off1 Bit1.1 switchCT
91[T1] On/Off Input1 = On; 0 = Off1 Bit1.1 switchCW
92[T1] Set-point FeedbackCurrent Set-point2 Bytes9.1 temperature (°C)CT
93[T1] Set-point InputSet-point2 Bytes9.1 temperature (°C)CW
93[T1] Comfort Set-point InputComfort Set-point2 Bytes9.1 temperature (°C)CW
94[T1] OutputOutput (PWM Proportional - Integral)1 Bit1.1 switchCT
94[T1] OutputOutput (% Proportional - Integral)1 Byte5.1 percentage (0..100%)CT
94[T1] Heating OutputOutput (PWM Proportional - Integral)1 Bit1.1 switchCT
94[T1] Heating OutputOutput (2-point with Hysteresis)1 Bit1.1 switchCT
94[T1] Heating OutputOutput (% Proportional - Integral)1 Byte5.1 percentage (0..100%)CT
94[T1] OutputOutput (2-point with Hysteresis)1 Bit1.1 switchCT
95[T1] Cooling OutputOutput (% Proportional - Integral)1 Byte5.1 percentage (0..100%)CT
95[T1] Cooling OutputOutput (2-point with Hysteresis)1 Bit1.1 switchCT
95[T1] Cooling OutputOutput (PWM Proportional - Integral)1 Bit1.1 switchCT
96[T1] Temperature Sensor 1Input Temperature Sensor 12 Bytes9.1 temperature (°C)CW
97[T1] Temperature Sensor 2Input Temperature Sensor 22 Bytes9.1 temperature (°C)CW
98[T1] Special mode Feedback2 Bytes mode Feedback2 Bytes22.101 RHCC statusCT
99[T1] Special mode Input 1 Byte1 Byte mode HVAC1 Byte20.102 HVAC modeCW
100[T1] Special mode Economy0 = Off; 1 = On1 Bit1.1 switchCW
101[T1] Special mode Stand-by0 = Off; 1 = On1 Bit1.1 switchCW
102[T1] Special mode Protection0 = Off; 1 = On1 Bit1.1 switchCW
103[T1] Special mode Comfort0 = Off; 1 = On1 Bit1.1 switchCW
104[T1] Heating or Cooling mode Status0=Cooling; 1=Heating1 Bit1.1 switchCT
105[T1] Heating or Cooling mode0=Cooling; 1=Heating1 Bit1.1 switchCW
106[T1] Window Alarm 1 Input0=No Alarm; 1=Alarm1 Bit1.5 alarmCW
107[T1] Window Alarm 2 Input0=No Alarm; 1=Alarm1 Bit1.5 alarmCW
108[T1] Window Alarm 3 Input0=No Alarm; 1=Alarm1 Bit1.5 alarmCW
109[T1] Window Alarm 4 Input0=No Alarm; 1=Alarm1 Bit1.5 alarmCW
110[T2] On/Off Feedback1 = On; 0 = Off1 Bit1.1 switchCT
111[T2] On/Off Input1 = On; 0 = Off1 Bit1.1 switchCW
112[T2] Set-point FeedbackCurrent Set-point2 Bytes9.1 temperature (°C)CT
113[T2] Set-point InputSet-point2 Bytes9.1 temperature (°C)CW
113[T2] Comfort Set-point InputComfort Set-point2 Bytes9.1 temperature (°C)CW
114[T2] Heating OutputOutput (PWM Proportional - Integral)1 Bit1.1 switchCT
114[T2] OutputOutput (PWM Proportional - Integral)1 Bit1.1 switchCT
114[T2] OutputOutput (2-point with Hysteresis)1 Bit1.1 switchCT
114[T2] OutputOutput (% Proportional - Integral)1 Byte5.10 counter pulses (0..255)CT
114[T2] Heating OutputOutput (% Proportional - Integral)1 Byte5.10 counter pulses (0..255)CT
114[T2] Heating OutputOutput (2-point with Hysteresis)1 Bit1.1 switchCT
115[T2] Cooling OutputOutput (PWM Proportional - Integral)1 Bit1.1 switchCT
115[T2] Cooling OutputOutput (% Proportional - Integral)1 Byte5.10 counter pulses (0..255)CT
115[T2] Cooling OutputOutput (2-point with Hysteresis)1 Bit1.1 switchCT
116[T2] Temperature sensor 1Input Temperature Sensor 12 Bytes9.1 temperature (°C)CW
117[T2] Temperature sensor 2Input Temperature Sensor 22 Bytes9.1 temperature (°C)CW
118[T2] Special mode Feedback2 Bytes mode Feedback2 Bytes22.101 RHCC statusCT
119[T2] Special mode Input 1 Byte1 Byte mode HVAC1 Byte20.102 HVAC modeCW
120[T2] Special mode Economy0 = Off; 1 = On1 Bit1.1 switchCW
121[T2] Special mode Stand-by0 = Off; 1 = On1 Bit1.1 switchCW
122[T2] Special mode Protection0 = Off; 1 = On1 Bit1.1 switchCW
123[T2] Special mode Comfort0 = Off; 1 = On1 Bit1.1 switchCW
124[T2] Heating or Cooling mode Status0=Cooling; 1=Heating1 Bit1.1 switchCT
125[T2] Heating or Cooling mode0=Cooling; 1=Heating1 Bit1.1 switchCW
126[T2] Window Alarm 1 Input0=No Alarm; 1=Alarm1 Bit1.5 alarmCW
127[T2] Window Alarm 2 Input0=No Alarm; 1=Alarm1 Bit1.5 alarmCW
128[T2] Window Alarm 3 Input0=No Alarm; 1=Alarm1 Bit1.5 alarmCW
129[T2] Window Alarm 4 Input0=No Alarm; 1=Alarm1 Bit1.5 alarmCW
130[T3] On/Off Feedback1 = On; 0 = Off1 Bit1.1 switchCT
131[T3] On/Off Input1 = On; 0 = Off1 Bit1.1 switchCW
132[T3] Set-point FeedbackCurrent Set-point2 Bytes9.1 temperature (°C)CT
133[T3] Set-point InputSet-point2 Bytes9.1 temperature (°C)CW
133[T3] Comfort set-point InputComfort Set-point2 Bytes9.1 temperature (°C)CW
134[T3] Heating OutputOutput (PWM Proportional - Integral)1 Bit1.1 switchCT
134[T3] OutputOutput (2-point with Hysteresis)1 Bit1.1 switchCT
134[T3] OutputOutput (PWM Proportional - Integral)1 Bit1.1 switchCT
134[T3] OutputOutput (% Proportional - Integral)1 Byte5.10 counter pulses (0..255)CT
134[T3] Heating OutputOutput (% Proportional - Integral)1 Byte5.10 counter pulses (0..255)CT
134[T3] Heating OutputOutput (2-point with Hysteresis)1 Bit1.1 switchCT
135[T3] Cooling OutputOutput (PWM Proportional - Integral)1 Bit1.1 switchCT
135[T3] Cooling OutputOutput (% Proportional - Integral)1 Byte5.10 counter pulses (0..255)CT
135[T3] Cooling OutputOutput (2-point with Hysteresis)1 Bit1.1 switchCT
136[T3] Temperature Sensor 1Input Temperature Sensor 12 Bytes9.1 temperature (°C)CW
137[T3] Temperature Sensor 2Input Temperature Sensor 22 Bytes9.1 temperature (°C)CW
138[T3] Special mode Feedback2 Bytes mode Feedback2 Bytes22.101 RHCC statusCT
139[T3] Special mode Input 1 byte1 Byte mode HVAC1 Byte20.102 HVAC modeCW
140[T3] Special mode Economy0 = Off; 1 = On1 Bit1.1 switchCW
141[T3] Special mode Stand-by0 = Off; 1 = On1 Bit1.1 switchCW
142[T3] Special mode Protection0 = Off; 1 = On1 Bit1.1 switchCW
143[T3] Special mode Comfort0 = Off; 1 = On1 Bit1.1 switchCW
144[T3] Heating or Cooling mode Status0=Cooling; 1=Heating1 Bit1.1 switchCT
145[T3] Heating or Cooling mode0=Cooling; 1=Heating1 Bit1.1 switchCW
146[T3] Window Alarm 1 Input0=No Alarm; 1=Alarm1 Bit1.5 alarmCW
147[T3] Window Alarm 2 Input0=No Alarm; 1=Alarm1 Bit1.5 alarmCW
148[T3] Window Alarm 3 Input0=No Alarm; 1=Alarm1 Bit1.5 alarmCW
149[T3] Window Alarm 4 Input0=No Alarm; 1=Alarm1 Bit1.5 alarmCW
150[T4] On/Off Feedback1 = On; 0 = Off1 Bit1.1 switchCT
151[T4] On/Off Input1 = On; 0 = Off1 Bit1.1 switchCW
152[T4] Set-point FeedbackCurrent Set-point2 Bytes9.1 temperature (°C)CT
153[T4] Set-point InputSet-point2 Bytes9.1 temperature (°C)CW
153[T4] Comfort set-point InputComfort Set-point2 Bytes9.1 temperature (°C)CW
154[T4] Heating OutputOutput (PWM Proportional - Integral)1 Bit1.1 switchCT
154[T4] OutputOutput (2-point with Hysteresis)1 Bit1.1 switchCT
154[T4] OutputOutput (PWM Proportional - Integral)1 Bit1.1 switchCT
154[T4] OutputOutput (% Proportional - Integral)1 Byte5.10 counter pulses (0..255)CT
154[T4] Heating OutputOutput (% Proportional - Integral)1 Byte5.10 counter pulses (0..255)CT
154[T4] Heating OutputOutput (2-point with Hysteresis)1 Bit1.1 switchCT
155[T4] Cooling Output Output (PWM Proportional - Integral)1 Bit1.1 switchCT
155[T4] Cooling Output Output (2-point with Hysteresis)1 Bit1.1 switchCT
155[T4] Cooling Output Output (% Proportional - Integral)1 Byte5.10 counter pulses (0..255)CT
156[T4] Temperature Sensor 1Input Temperature Sensor 12 Bytes9.1 temperature (°C)CW
157[T4] Temperature Sensor 2Input Temperature Sensor 22 Bytes9.1 temperature (°C)CW
158[T4] Special mode Feedback2 Bytes mode Feedback2 Bytes22.101 RHCC statusCT
159[T4] Special mode Input 1 Byte1 Byte mode HVAC1 Byte20.102 HVAC modeCW
160[T4] Special mode Economy0 = Off; 1 = On1 Bit1.1 switchCW
161[T4] Special mode Stand-by0 = Off; 1 = On1 Bit1.1 switchCW
162[T4] Special mode Protection0 = Off; 1 = On1 Bit1.1 switchCW
163[T4] Special mode Comfort0 = Off; 1 = On1 Bit1.1 switchCW
164[T4] Heating or Cooling mode Status0=Cooling; 1=Heating1 Bit1.1 switchCT
165[T4] Heating or Cooling mode0=Cooling; 1=Heating1 Bit1.1 switchCW
166[T4] Window Alarm 1 Input0=No Alarm; 1=Alarm1 Bit1.5 alarmCW
167[T4] Window Alarm 2 Input0=No Alarm; 1=Alarm1 Bit1.5 alarmCW
168[T4] Window Alarm 3 Input0=No Alarm; 1=Alarm1 Bit1.5 alarmCW
169[T4] Window Alarm 4 Input0=No Alarm; 1=Alarm1 Bit1.5 alarmCW
Parameters (252)
ParameterTypeDefault
RASTRO_ETSunsignedInt 0…25516
Function of Input 1listNot assigned
Debounce timelist10msec
Distinction between Short and Long pressunsignedInt 0…10
Contact typelistNormally Open
Long press afterlist0,3sec
Number of objects for Short/Long presslist1
Short presslistOn
Long presslistOn
Cyclical transmissionlistNo
Action on Closing the contactlistOn
Action on Opening the contactlistOn
Transmit state after recovering bus voltageunsignedInt 0…10
Cycle base timelist1sec
Factor (Total time = Base x Factor)unsignedInt 0…2557
Dimming FunctionalitylistDimming and Switching
Action on presslistDim Brighter / Darker
Long presslistDim Brighter / Darker
Save scene on Long pressunsignedInt 0…10
Maximum time between two presslist0,5sec
Number of presslist2
Press 1 actionlistOn
Press 2 actionlistOn
Press 3 actionlistOn
Press 4 actionlistOn
Number of objectslist2
Functional Constructionlist1 Pushbutton
Shutter FunctionalitylistShort = Step, Long = Move
Long presslistMove Up
Short presslistStep Down
Value type on Short presslist1 Bit
Value type on Long presslist1 Bit
Signlist+
Integer partunsignedInt 0…990
Decimal partunsignedInt 0…990
2 Bytes valueunsignedInt 0…655350
2 Bytes signed valuesignedInt -32768…327670
4 Bytes valueunsignedInt 0…42949672950
1 Bit valuelist0
2 Bits valuelist00
1 Byte valueunsignedInt 0…2550
Value type on presslist1 Bit
Type of Scene Controllist8-Bit Scene
Scene NumberunsignedInt 1…641
Short presslistCall
Save ScenelistNo
Scene Number 1/2unsignedInt 1…21
Data Counter widthlist8
Start value (0-255)unsignedInt 0…2550
Start value (0-65535)unsignedInt 0…655350
Start value (0-4.294.967.295)unsignedInt 0…42949672950
Temperature sending base timelist1min
Temperature variation to sendunsignedInt 5…2005
Protection AlarmslistNo Protection
HysteresisunsignedInt 0…500
Over-Heating temperaturelist-30
Over-Cooling temperaturelist-30
Temperature Functionality enabled after recovering bus voltageunsignedInt 0…10
Temperature Sensor calibration valuelist0
Function of Input 2listNot assigned
Save Scene on Long pressunsignedInt 0…10
Bit valuelist0
Over-Heating Temperaturelist-30
Over-Cooling Temperaturelist-30
Function of Input 3listNot assigned
Function of Input 4listNot assigned
Enable Thermostat 1unsignedInt 0…10
ModelistCooling Thermostat
Reference Temperature SourcelistOne source
Thermostat always onunsignedInt 0…10
State after recovering bus voltagelistOff
Enable turn-on Thermostat when Special telegram arrivesunsignedInt 0…10
Send Thermostat Set-point after recovering bus voltageunsignedInt 0…10
Enable automatic mode changeunsignedInt 0…10
Mode after recovering bus voltagelistCooling Thermostat
Control objectlistDifferent objects for Heating and Cooling
Set-point modelistAbsolute Set-point mode
Initial Set-point after recovering bus voltageunsignedInt 5…4524
Save Set-point after mode change via objectunsignedInt 0…10
Mode after recovering bus voltagelistComfort
Enable 1-Bit mode objectslistDisable
Enable Window ProtectionunsignedInt 0…10
Comfort mode Set-pointunsignedInt 5…4522
Offset for Stand-by Set-point modelist-100
Offset for Economy Set-point modelist-100
Set-point for Protection from FreezingunsignedInt 0…158
Comfort mode Set-pointunsignedInt 5…455
Offset for Stand-by Set-point modeunsignedInt 0…9964
Offset for Economy Set-point modeunsignedInt 0…9996
Over-Temperature Protection Set-pointunsignedInt 30…4540
Regulation modelist2-point with hysteresis control
Higher HysteresisunsignedInt 5…4510
Lower HysteresisunsignedInt 5…4510
Forwarding period (0=Disable)unsignedInt 0…2550
PWM typelistPWM (1bit)
PI cycle timeunsignedInt 0…255255
Proportional bandunsignedInt 0…155
Attenuation factorunsignedInt 0…9931
Maximum Integral component (%)unsignedInt 0…995
Enable Thermostat 2unsignedInt 0…10
Confort mode Set-pointunsignedInt 5…4522
Over-temperature Protection Set-pointunsignedInt 30…4540
Enable Thermostat 3unsignedInt 0…10
Save set point after mode change via objectunsignedInt 0…10
Enable Thermostat 4unsignedInt 0…10
Transmision and switching delay after recovering bus voltage (2..255s)unsignedInt 2…2552
Operating modelist2-channel Switch Actuator
Switch FeedbacklistNo
Object value of Switch FeedbacklistClosed=1, Open=0
Reaction after bus failurelistOpen contact
Object "Switch On/Off" after recovering bus voltagelistSet object to 0
Output polaritylistNormally open contact
Enable Time FunctionunsignedInt 0…10
Time FunctionlistStaircase light Time Switch
Object "Disable Time Function" after recovering bus voltagelist0: Enable Time Function
Enable Preset FunctionunsignedInt 0…10
Enable Scene FunctionunsignedInt 0…10
Enable Logical FunctionunsignedInt 0…10
Enable Forced FunctionunsignedInt 0…10
Enable Threshold FunctionunsignedInt 0…10
Staircase light Time Switch timing (sec)unsignedInt 0…655350
Timer is retriggerableunsignedInt 0…10
Staircase light Time Switch early switch-offlistON with 1, OFF with 0
Pre-warning before end of timelistNo
Pre-warning time (sec)unsignedInt 0…6553516
Staircase time changeable via objectunsignedInt 0…10
On delay time (sec)unsignedInt 0…655351
Off delay time (sec)unsignedInt 0…655351
Flashing when object "Time Switch" islistOn (1)
Flash On time (sec)unsignedInt 0…655355
Flash Off time (sec)unsignedInt 0…655355
Reaction on Preset 1 (telegram 0)listNo reaction
Reaction on Preset 2 (telegram 1)listNo reaction
Preset can be set via busunsignedInt 0…10
Scene 1listScene 1
Scene 1 Preset valuelistOff
Scene 2listScene 2
Scene 2 Preset ValuelistOff
Scene 3listScene 3
Scene 3 Preset ValuelistOff
Scene 4listScene 4
Scene 4 Preset ValuelistOff
Scene 5listScene 5
Scene 5 Preset ValuelistOff
Logical connection 1 enableunsignedInt 0…11
Logical connection 1 FunctionlistAND
Logical connection 1 invertedunsignedInt 0…10
Object value "Logical connection 1" after recovering bus voltagelistOn
Logical connection 2 enableunsignedInt 0…10
Logical connection 2 FunctionlistAND
Logical connection 2 invertedunsignedInt 0…10
Object value "Logical connection 2" after recovering bus voltagelistOff
Object "Forced" typelist1-Bit object
Object "Forced" polaritylistForced object 1: Switch Off
Object "Forced" state after recovering bus voltagelistNot Forced
Data type of object "Threshold Input"list1 Byte (0..255)
Change Threshold value 1 over the busunsignedInt 0…10
Threshold value 1 (0..255)unsignedInt 0…255255
Threshold value 2 (0..255)unsignedInt 0…2550
Threshold value 1 (0..65535)unsignedInt 0…6553550000
Threshold value 2 (0..65535)unsignedInt 0…655350
Action if value between Threshold 1 and 2unsignedInt 0…10
Threshold value after recovering bus voltageunsignedInt 0…2550
Threshold value after recovering bus voltageunsignedInt 0…655350
Object value < Threshold value 1listNo reaction
Object value > Threshold value 2listNo reaction
Value 1 ≤ Object value ≤ Value 2listNo reaction
Object "Switch On / Off" value after recovering bus voltagelistSet object to 0
Value object "Disable Time Function" after recovering bus voltagelist0: Enable Time Function
Enable Logic FunctionunsignedInt 0…10
Type of devicelistVenetian Blind
Reaction after bus failurelistStop
Behavior after recovering bus voltagelistNo action
Venting Louver position (0-100%) after recovering bus voltageunsignedInt 0…1000
Slats position (0-100%) after recovering bus voltageunsignedInt 0…1000
Extra time for Up movement (%)unsignedInt 0…300
Forced vs Weather Alarm Prioritylist1-Forced operation 2-Weather Alarm
Reversion Pause time (msec)unsignedInt 499…5000500
Step operation possiblelistNo (only Stop)
Step length (x 0,1sec)unsignedInt 2…60010
Roller Movement time (sec)unsignedInt 1…36001
Slats Movement time (x 0,1sec)unsignedInt 2…60020
Time to send "Current position" (sec)unsignedInt 60…360060
Time to send "Slats position" (sec)unsignedInt 60…360060
Enable object: Movement FeedbackunsignedInt 0…10
Enable Weather AlarmsunsignedInt 0…10
Enable object: Wind Alarm 1unsignedInt 0…10
Enable object: Wind Alarm 2unsignedInt 0…10
Enable object: Wind Alarm 3unsignedInt 0…10
Enable object: Rain AlarmunsignedInt 0…10
Enable object: Frost AlarmunsignedInt 0…10
Enable Wind Alarm WatchdogunsignedInt 0…10
Wind Alarm Watchdog time (sec)unsignedInt 10…655353600
Enable Rain Alarm WatchdogunsignedInt 0…10
Rain Alarm Watchdog time (sec)unsignedInt 10…6553510
Enable Frost Alarm WatchdogunsignedInt 0…10
Frost Alarm Watchdog time (sec)unsignedInt 10…6553510
Behavior when starting Wind AlarmlistNo action
Behavior when finishing Wind AlarmlistNo action
Behavior when starting Rain AlarmlistNo action
Behavior when finishing Rain AlarmlistNo action
Behavior when starting Frost AlarmlistNo action
Behavior when finishing Frost AlarmlistNo action
Weather Alarms prioritylistWind > Rain > Frost
Enable Sun ProtectionunsignedInt 0…10
Type of Protection objectlist1 Bit On /Off Protection object
Sun Protection object polaritylist1: Sun Protection On
Lux value to Start ProtectionunsignedInt 1…36001000
Lux value to Finish ProtectionunsignedInt 1…3600500
Delay time to Start Sun Protection (sec)unsignedInt 1…36001
Behavior when starting Sun ProtectionlistNo action
Scene NumberlistScene 1
Position (%)unsignedInt 0…1000
Slats position (%)unsignedInt 0…1000
Delay time to Finish Sun Protection (sec)unsignedInt 1…36001
Behavior when finishing Sun ProtectionlistNo action
Enable Scene FunctionalityunsignedInt 0…10
Scene 1 Position (%)unsignedInt 0…1000
Scene 2 Position (%)unsignedInt 0…1000
Scene 3 Position (%)unsignedInt 0…1000
Scene 4 Position (%)unsignedInt 0…1000
Scene 5 Position (%)unsignedInt 0…1000
Scene 6listScene 6
Scene 6 Position (%)unsignedInt 0…1000
Scene 7listScene 7
Scene 7 Position (%)unsignedInt 0…1000
Scene 8listScene 8
Scene 8 position (%)unsignedInt 0…1000
Scene 1 Slats Position (%)unsignedInt 0…1000
Scene 2 Slats Position (%)unsignedInt 0…1000
Scene 3 Slats Position (%)unsignedInt 0…1000
Scene 4 Slats Position (%)unsignedInt 0…1000
Scene 5 Slats Position (%)unsignedInt 0…1000
Scene 6 Slats Position (%)unsignedInt 0…1000
Scene 7 Slats Position (%)unsignedInt 0…1000
Scene 8 Slats Position (%)unsignedInt 0…1000
Forced state after recovering bus voltagelistNot Forced
Fabric tensioning time (sec)unsignedInt 0…2550
Enable object: Blind position Feedback %unsignedInt 0…10
Enable object: Slats position Feedback %unsignedInt 0…10
Blind position (0-100%) after recovering bus voltageunsignedInt 0…1000
Roller position (0-100%) after recovering bus voltageunsignedInt 0…1000
Blind Movement time (sec)unsignedInt 1…36001
Louver Movement time (sec)unsignedInt 1…36001
Enable object: Roller position Feedback %unsignedInt 0…10
Enable object: Louver position Feedback %unsignedInt 0…10
Initial Comfort Set-point after recovering bus voltageunsignedInt 5…4524
Save Offset after mode change via objectunsignedInt 0…10
Temperature sending factor time (Total time = Base x Factor) (0=Disable send)unsignedInt 0…2557
Action on presslistMove Up
Action on presslistMove Up
Factor time to send temperature (Total time = Base x Factor) (0=Disable send)unsignedInt 0…2557

Version history

ApplicationApp noFingerprintFirst seenSizeFile
DINUY_PEKNT002 0.0 latest$20035F612026-11-25193 KBDownload

About this file

This is the official ETS product database for the Dinuy Actuator 1ch Blind / 2ch Switch - 4 Inputs (PE KNT 002), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.

More from Dinuy

All Dinuy products