Dinuy PE KNT 001 Actuator 2 ch Switch/Blind

Actuator 2 ch Switch/Blind PE KNT 001

Dinuy · Order number PE KNT 001 · KNX-TP Devices › Actuators › Switch and Shutter/Blind Actuators

Download .knxprod DINUY Actuator 2-channel Switch/Blinds 0.0 · 175 KB

Product

ManufacturerDinuy
Product nameActuator 2 ch Switch/Blind
Order numberPE KNT 001
HardwareActuator 2 ch Switch/Blind
MediumTwisted Pair
Bus current (mA)10
Rail mountedNo
RegistrationCertified · 2018-08-07
Languageses-ES
Catalog entryM-009A_H-009APEKNT001300518-0_HP-2001-00-1FEE_CI-PE.20KNT.20001-1
Fingerprint1FEE
SHA-2561c223efaf6ccf2883646fbdb057ffc5ce3c9dd9f208d26b6c81050f4551ce410
First seen2026-11-25
Markets68 markets

Application program: DINUY Actuator 2-channel Switch/Blinds 0.0

Application number$2001
Version0.0
Mask versionMV-0705 (7.5)
KNX Data SecureNo
Minimum ETS version5.0
Parameters650
Group objects339
Group objects (339)
NoNameFunctionSizeDPTFlags
0INPUT A (via Bus)Disable Channel A1 Bit1.3 enableCW
0Disable object Temperature functionality Channel A1=Disable; 0=Enable1 Bit1.3 enableCW
1INPUT A2 Bytes value Telegram A on operation2 Bytes7.1 pulsesCRWTU
1INPUT A8 Bit scene1 Byte18.1 scene controlCRWTU
1INPUT ACounter Direction1 Bit1.8 up/downCRWTU
1INPUT AScene Group A 1/21 Bit1.11 stateCRWTU
1INPUT AStep Telegram A1 Bit1.7 stepCRWTU
1INPUT ABit value Telegram A on operation1 Bit1.11 stateCRWTU
1INPUT A4 Bytes value Telegram A on operation4 Bytes12.1 counter pulses (unsigned)CRWTU
1INPUT A2 Bits value Telegram A on operation2 Bit2.1 switch controlCRWTU
1INPUT AByte value Telegram A on operation1 Byte5.10 counter pulses (0..255)CRWTU
1INPUT A2 Bytes Floating value Telegram A on operation2 Bytes9.1 temperature (°C)CRWTU
1INPUT A2 Bytes signed value Telegram A on operation2 Bytes8.1 pulses differenceCRWTU
1OUTPUT ATemperature Value2 Bytes9.1 temperature (°C)CRWTU
1INPUT ASwitch Telegram A1 Bit1.1 switchCRWTU
2INPUT ABit value Telegram A on Long operation1 Bit1.11 stateCRWTU
2INPUT A2 Bytes value Telegram A on Long operation2 Bytes7.1 pulsesCRWTU
2INPUT A2 Bytes signed value Telegram A on Long operation2 Bytes8.1 pulses differenceCRWTU
2INPUT A4 Bytes value Telegram A on Long operation4 Bytes12.1 counter pulses (unsigned)CRWTU
2INPUT AStore Scene object1 Bit1.3 enableCRWTU
2INPUT A2 Bytes Floating value Telegram A on Long operation2 Bytes9.1 temperature (°C)CRWTU
2INPUT AReset Counter 1 Bit1.15 resetCRWTU
2OUTPUT A Sensor not connected0=Sensor Ok; 1=Sensor not connected1 Bit1.11 stateCRWTU
2INPUT AByte value Telegram A on Long operation1 Byte5.10 counter pulses (0..255)CRWTU
2INPUT ASwitch Telegram Long A1 Bit1.1 switchCRWTU
2INPUT ADimming Control Telegram A4 Bit3.7 dimming controlCRWTU
2INPUT ASwitch Telegram A-21 Bit1.1 switchCRWTU
2INPUT AMove Telegram A1 Bit1.8 up/downCRWTU
2INPUT A2 Bits value Telegram A on Long operation2 Bit2.1 switch controlCRWTU
3INPUT A (via Bus)Info Switch1 Bit1.1 switchCW
3OUTPUT A Over-heating1= Over-Cooling; 0= No Over-Cooling1 Bit1.5 alarmCRWTU
3INPUT ASwitch Telegram A-31 Bit1.1 switchCRWTU
3INPUT ARequest Counter1 Bit1.17 triggerCRWTU
4INPUT ASwitch Telegram A-41 Bit1.1 switchCRWTU
4INPUT ACounter (0-4.294.967.295)4 Bytes13.1 counter pulses (signed)CRWTU
4OUTPUT A Over-cooling1= Over-Cooling; 0= No Over-Cooling1 Bit1.5 alarmCRWTU
4INPUT A (via Bus)Info Switch Long1 Bit1.1 switchCW
4INPUT ACounter (0-65535)2 Bytes7.1 pulsesCRWTU
4INPUT ACounter (0-255)1 Byte5.10 counter pulses (0..255)CRWTU
5INPUT ASwitch Telegram A-51 Bit1.1 switchCRWTU
6INPUT A Store Scene object1 Bit1.1 switchCRWTU
6INPUT A (via Bus)Increase/Decrease A1 Bit1.8 up/downCRWTU
7Disable object Temperature functionality Channel B1=Disable; 0=Enable1 Bit1.11 stateCW
7INPUT B (via Bus)Disable Channel B1 Bit1.3 enableCW
8INPUT B2 Bytes Floating value Telegram B on operation2 Bytes9.1 temperature (°C)CRWTU
8INPUT B2 Bits value Telegram B on operation2 Bit2.1 switch controlCRWTU
8INPUT BByte value Telegram B on operation1 Byte5.10 counter pulses (0..255)CRWTU
8INPUT B2 Bytes signed value Telegram B on operation2 Bytes8.1 pulses differenceCRWTU
8INPUT B2 Bytes value Telegram B on operation2 Bytes7.1 pulsesCRWTU
8INPUT BScene Group B 1/21 Bit1.11 stateCRWTU
8INPUT B4 Bytes value Telegram B on operation4 Bytes12.1 counter pulses (unsigned)CRWTU
8INPUT B8 Bit scene1 Byte18.1 scene controlCRWTU
8INPUT BBit value Telegram B on operation1 Bit1.11 stateCRWTU
8INPUT BCounter Direction1 Bit1.8 up/downCRWTU
8OUTPUT BTemperature Value2 Bytes9.1 temperature (°C)CRWTU
8INPUT BStep Telegram B1 Bit1.7 stepCRWTU
8INPUT BSwitch Telegram B1 Bit1.1 switchCRWTU
9INPUT BByte value Telegram B on Long operation1 Byte5.10 counter pulses (0..255)CRWTU
9INPUT BMove Telegram B1 Bit1.8 up/downCRWTU
9INPUT B4 Bytes value Telegram B on Long operation4 Bytes12.1 counter pulses (unsigned)CRWTU
9INPUT B2 Bits value Telegram B on Long operation2 Bit2.1 switch controlCRWTU
9INPUT BBit value Telegram B on Long operation1 Bit1.11 stateCRWTU
9INPUT B2 Bytes signed value Telegram B on Long operation2 Bytes8.1 pulses differenceCRWTU
9INPUT B2 Bytes value Telegram B on Long operation2 Bytes7.1 pulsesCRWTU
9INPUT B2 Bytes Floating value Telegram B on Long operation2 Bytes9.1 temperature (°C)CRWTU
9INPUT BSwitch Telegram B-21 Bit1.1 switchCRWTU
9INPUT BStore Scene object1 Bit1.3 enableCRWTU
9OUTPUT B Sensor not connected0=Sensor Ok; 1=Sensor not connected1 Bit1.11 stateCRWTU
9INPUT BReset Counter1 Bit1.15 resetCRWTU
9INPUT BDimming Control Telegram B4 Bit3.7 dimming controlCRWTU
9[T1] On/Off (Status)Switch Telegram Long B1 Bit1.1 switchCRWTU
10OUTPUT B Over-heating 1= Over-Cooling; 0= No Over-Cooling1 Bit1.5 alarmCRWTU
10INPUT B (via Bus)Info Switch1 Bit1.1 switchCW
10INPUT BRequest Counter1 Bit1.17 triggerCRWTU
10INPUT BSwitch Telegram B-31 Bit1.1 switchCRWTU
11INPUT BCounter (0-255)1 Byte5.10 counter pulses (0..255)CRWTU
11OUTPUT B Over-cooling1= Over-Cooling; 0= No Over-Cooling1 Bit1.5 alarmCRWTU
11INPUT BSwitch Telegram B-41 Bit1.1 switchCRWTU
11INPUT B (via Bus)Info Switch Long1 Bit1.1 switchCW
11INPUT BCounter (0-4.294.967.295)4 Bytes13.1 counter pulses (signed)CRWTU
11INPUT BCounter (0-65535)2 Bytes7.1 pulsesCRWTU
12INPUT BSwitch Telegram B-51 Bit1.1 switchCRWTU
13INPUT BStore Scene object1 Bit1.3 enableCRWTU
13INPUT B (via Bus)Increase/Decrease B1 Bit1.8 up/downCRWTU
14Disable object Temperature functionality Channel C1=Disable; 0=Enable1 Bit1.11 stateCW
14INPUT C (via Bus)Disable Channel C1 Bit1.3 enableCW
15INPUT CStep Telegram C1 Bit1.7 stepCRWTU
15OUTPUT CTemperature Value2 Bytes9.1 temperature (°C)CRWTU
15INPUT CCounter Direction1 Bit1.8 up/downCRWTU
15INPUT CScene Group C 1/21 Bit1.11 stateCRWTU
15INPUT C8 Bit scene1 Byte18.1 scene controlCRWTU
15INPUT C2 Bits value Telegram C on operation2 Bit2.1 switch controlCRWTU
15INPUT C4 Bytes value Telegram C on operation4 Bytes12.1 counter pulses (unsigned)CRWTU
15INPUT C2 Bytes Floating value Telegram C on operation2 Bytes9.1 temperature (°C)CRWTU
15INPUT C2 Bytes value Telegram C on operation2 Bytes7.1 pulsesCRWTU
15INPUT C2 Bytes signed value Telegram C on operation2 Bytes8.1 pulses differenceCRWTU
15INPUT CByte value Telegram C on operation1 Byte5.10 counter pulses (0..255)CRWTU
15INPUT CSwitch Telegram C1 Bit1.1 switchCRWTU
15INPUT CBit value Telegram C on operation1 Bit1.11 stateCRWTU
16INPUT CSwitch Telegram Long C1 Bit1.1 switchCRWTU
16INPUT CBit value Telegram C on Long operation1 Bit1.11 stateCRWTU
16INPUT CSwitch Telegram C-21 Bit1.1 switchCRWTU
16INPUT C2 Bits value Telegram C on Long operation2 Bit2.1 switch controlCRWTU
16OUTPUT C Sensor no connected0=Sensor Ok; 1=Sensor not connected1 Bit1.11 stateCRWTU
16INPUT C2 Bytes signed value Telegram C on Long operation2 Bytes8.1 pulses differenceCRWTU
16INPUT C2 Bytes value Telegram C on Long operation2 Bytes7.1 pulsesCRWTU
16INPUT C2 Bytes Floating value Telegram C on Long operation2 Bytes9.1 temperature (°C)CRWTU
16INPUT CMove Telegram C1 Bit1.8 up/downCRWTU
16INPUT C4 Bytes value Telegram C on Long operation4 Bytes12.1 counter pulses (unsigned)CRWTU
16INPUT CStore Scene object1 Bit1.3 enableCRWTU
16INPUT CReset Counter1 Bit1.15 resetCRWTU
16INPUT CByte value Telegram C on Long operation1 Byte5.10 counter pulses (0..255)CRWTU
16INPUT CDimming Control Telegram C4 Bit3.7 dimming controlCRWTU
17INPUT CRequest Counter1 Bit1.17 triggerCRWTU
17INPUT C (via Bus)Info Switch1 Bit1.1 switchCT
17INPUT CSwitch Telegram C-31 Bit1.1 switchCRWTU
17OUTPUT C Over-heating1= Over-Cooling; 0= No Over-Cooling1 Bit1.5 alarmCRWTU
18INPUT CCounter (0-4.294.967.295)4 Bytes13.1 counter pulses (signed)CRWTU
18INPUT C (via Bus)Info Switch Long1 Bit1.1 switchCT
18OUTPUT C Over-cooling1= Over-Cooling; 0= No Over-Cooling1 Bit1.5 alarmCRWTU
18INPUT CCounter (0-255)1 Byte5.10 counter pulses (0..255)CRWTU
18INPUT CCounter (0-65535)2 Bytes7.1 pulsesCRWTU
18INPUT CSwitch Telegram C-41 Bit1.1 switchCRWTU
19INPUT CSwitch Telegram C-51 Bit1.1 switchCRWTU
20INPUT C (via Bus)Increase/Decrease C1 Bit1.8 up/downCRWTU
20INPUT CStore Scene object1 Bit1.3 enableCRWTU
21Disable object Temperature functionality Channel D1=Disable; 0=Enable1 Bit1.11 stateCW
21INPUT D (via Bus)Disable Channel D1 Bit1.3 enableCW
22INPUT DCounter Direction1 Bit1.8 up/downCRWTU
22INPUT D2 Bits value Telegram D on operation2 Bit2.1 switch controlCRWTU
22INPUT D4 Bytes value Telegram D on operation4 Bytes12.1 counter pulses (unsigned)CRWTU
22INPUT D2 Bytes Floating value Telegram D on operation2 Bytes9.1 temperature (°C)CRWTU
22INPUT D2 Bytes value Telegram D on operation2 Bytes7.1 pulsesCRWTU
22INPUT D2 Bytes signed value Telegram D on operation2 Bytes8.1 pulses differenceCRWTU
22INPUT DByte value Telegram D on operation1 Byte5.10 counter pulses (0..255)CRWTU
22INPUT DBit value Telegram D on operation1 Bit1.11 stateCRWTU
22INPUT DStep Telegram D1 Bit1.7 stepCRWTU
22INPUT DSwitch Telegram D1 Bit1.1 switchCRWTU
22INPUT D8 Bit scene1 Byte18.1 scene controlCRWTU
22INPUT DScene Group D 1/21 Bit1.11 stateCRWTU
22OUTPUT DTemperature Value2 Bytes9.1 temperature (°C)CRWTU
23INPUT D4 Bytes value Telegram D on Long operation4 Bytes12.1 counter pulses (unsigned)CRWTU
23INPUT DBit value Telegram D on Long operation1 Bit1.11 stateCRWTU
23INPUT DByte value Telegram D on Long operation1 Byte5.10 counter pulses (0..255)CRWTU
23INPUT D2 Bytes value Telegram D on Long operation2 Bytes7.1 pulsesCRWTU
23INPUT DMove Telegram D1 Bit1.8 up/downCRWTU
23INPUT D2 Bits value Telegram D on Long operation2 Bit2.1 switch controlCRWTU
23INPUT DSwitch Telegram Long D1 Bit1.1 switchCRWTU
23INPUT D2 Bytes signed value Telegram D on Long operation2 Bytes8.1 pulses differenceCRWTU
23INPUT DSwitch Telegram D-21 Bit1.1 switchCRWTU
23INPUT DDimming Control Telegram D4 Bit3.7 dimming controlCRWTU
23INPUT D2 Bytes Floating value Telegram D on Long operation2 Bytes9.1 temperature (°C)CRWTU
23INPUT DStore Scene object1 Bit1.3 enableCRWTU
23INPUT DReset Counter1 Bit1.15 resetCRWTU
23OUTPUT D Sensor not connected0=Sensor Ok; 1=Sensor not connected1 Bit1.11 stateCRWTU
24INPUT D (via Bus)Info Switch1 Bit1.1 switchCT
24INPUT DRequest Counter1 Bit1.17 triggerCRWTU
24INPUT DSwitch Telegram D-31 Bit1.1 switchCRWTU
24OUTPUT D Overheating1= Over-Cooling; 0= No Over-Cooling1 Bit1.5 alarmCRWTU
25INPUT DCounter (0-255)1 Byte5.10 counter pulses (0..255)CRWTU
25OUTPUT D Overcooling1= Over-Cooling; 0= No Over-Cooling1 Bit1.5 alarmCRWTU
25INPUT DSwitch Telegram D-41 Bit1.1 switchCRWTU
25INPUT D (via Bus)Info Switch Long1 Bit1.1 switchCW
25INPUT DCounter (0-65535)2 Bytes7.1 pulsesCRWTU
25INPUT DCounter (0-4.294.967.295)4 Bytes13.1 counter pulses (signed)CRWTU
26INPUT DSwitch Telegram D-51 Bit1.1 switchCRWTU
27INPUT DStore Scene object1 Bit1.3 enableCRWTU
27INPUT D (via Bus)Increase/Decrease D1 Bit1.8 up/downCRWTU
28[T1] On/Off (Status)1= On; 0= Off1 Bit1.1 switchCRWT
29[T1] On/Off1= On; 0= Off1 Bit1.1 switchCWT
30[T1] Set-point InformationCurrent Set-point2 Bytes9.1 temperature (°C)CRWT
31[T1] Confort Set-point InputConfort Set-point2 Bytes9.1 temperature (°C)CWT
31[T1] Set-point InputSet-point2 Bytes9.1 temperature (°C)CWT
32[T1] OutputOutput (% Proportional - Integral)1 Byte5.1 percentage (0..100%)CRWT
32[T1] OutputOutput (PWM Proportional - Integral)1 Bit1.1 switchCRWT
32[T1] Output HeatingOutput (% Proportional - Integral)1 Byte5.1 percentage (0..100%)CRWT
32[T1] OutputOutput (2 points with Hysteresis)1 Bit1.1 switchCRWT
32[T1] Output HeatingOutput (2 points with Hysteresis)1 Bit1.1 switchCRWT
32[T1] Output HeatingOutput (PWM Proportional - Integral)1 Bit1.1 switchCRWT
33[T1] Output CoolingOutput (% Proportional - Integral)1 Byte5.1 percentage (0..100%)CRWT
33[T1] Output CoolingOutput (PWM Proportional - Integral)1 Bit1.1 switchCRWT
33[T1] Output CoolingOutput (2 points with Hysteresis)1 Bit1.1 switchCRWT
34[T1] Temperature Sensor 1Input Temperature Sensor 12 Bytes9.1 temperature (°C)CRWT
35[T1] Temperature Sensor 2Input Temperature Sensor 22 Bytes9.1 temperature (°C)CRWTU
36[T1] Special mode Info2 Bytes mode Info2 Bytes22.101 RHCC statusCRWT
37[T1] Special mode Input 1 byte1 byte mode HVAC1 Byte20.102 HVAC modeCRWTU
38[T1] Special mode Economic0=Off; 1=On1 Bit1.1 switchCRWT
39[T1] Special mode Stand-by0=Off; 1=On1 Bit1.1 switchCRWT
40[T1] Special mode Protection0=Off; 1=On1 Bit1.1 switchCRWT
41[T1] Special mode Confort0=Off; 1=On1 Bit1.1 switchCRWT
42[T1] Heating or Cooling mode Status0=Cooling; 1=Heating1 Bit1.1 switchCRWTU
43[T1] Heating or Cooling mode0=Cooling; 1=Heating1 Bit1.1 switchCRWTU
44[T1] Window alarm 10=No alarm; 1=Alarm1 Bit1.5 alarmCRWTU
45[T1] Window alarm 20=No alarm; 1=Alarm1 Bit1.5 alarmCRWTU
46[T1] Window alarm 30=No alarm; 1=Alarm1 Bit1.5 alarmCRWTU
47[T1] Window alarm 40=No alarm; 1=Alarm1 Bit1.5 alarmCRWTU
48[T2] On/Off (Status)1= On; 0= Off1 Bit1.1 switchCRWT
49[T2] On/Off1= On; 0= Off1 Bit1.1 switchCWT
50[T2] Set-point InformationCurrent Set-point2 Bytes9.1 temperature (°C)CRWT
51[T2] Confort set-point InputConfort Set-point2 Bytes9.1 temperature (°C)CWT
51[T2] Set-point InputSet-point2 Bytes9.1 temperature (°C)CWT
52[T2] OutputOutput (2 points with Hysteresis)1 Bit1.1 switchCRWT
52[T2] OutputOutput (% Proportional - Integral)1 Byte5.1 percentage (0..100%)CRWT
52[T2] Output HeatingOutput (% Proportional - Integral)1 Byte5.1 percentage (0..100%)CRWT
52[T2] Output HeatingOutput (PWM Proportional - Integral)1 Bit1.1 switchCRWT
52[T2] Output HeatingOutput (2 points with Hysteresis)1 Bit1.1 switchCRWT
52[T2] OutputOutput (PWM Proportional - Integral)1 Bit1.1 switchCRWT
53[T2] Output CoolingOutput (% Proportional - Integral)1 Byte5.1 percentage (0..100%)CRWT
53[T2] Output CoolingOutput (PWM Proportional - Integral)1 Bit1.1 switchCRWT
53[T2] Output CoolingOutput (2 points with Hysteresis)1 Bit1.1 switchCRWT
54[T2] Temperature sensor 1Input Temperature Sensor 12 Bytes9.1 temperature (°C)CRWT
55[T2] Temperature sensor 2Input Temperature Sensor 22 Bytes9.1 temperature (°C)CRWTU
56[T2] Special mode Info2 Bytes mode Info2 Bytes22.101 RHCC statusCRWT
57[T2] Special mode Input 1 byte1 byte mode HVAC1 Byte20.102 HVAC modeCRWTU
58[T2] Special mode Economic0=Off; 1=On1 Bit1.1 switchCRWT
59[T2] Special mode Stand-by0=Off; 1=On1 Bit1.1 switchCRWT
60[T2] Special mode Protection0=Off; 1=On1 Bit1.1 switchCRWT
61[T2] Special mode Confort0=Off; 1=On1 Bit1.1 switchCRWT
62[T2] Heating or Cooling mode Status0=Cooling; 1=Heating1 Bit1.1 switchCRWTU
63[T2] Heating or Cooling mode0=Cooling; 1=Heating1 Bit1.1 switchCRWTU
64[T2] Window alarm 10=No alarm; 1=Alarm1 Bit1.5 alarmCRWTU
65[T2] Window alarm 20=No alarm; 1=Alarm1 Bit1.5 alarmCRWTU
66[T2] Window alarm 30=No alarm; 1=Alarm1 Bit1.5 alarmCRWTU
67[T2] Window alarm 40=No alarm; 1=Alarm1 Bit1.5 alarmCRWTU
68[T3] On/Off (Status)1= On; 0= Off1 Bit1.1 switchCRWT
69[T3] On/Off1= On; 0= Off1 Bit1.1 switchCWT
70[T3] Set-point InformationCurrent Set-point2 Bytes9.1 temperature (°C)CRWT
71[T3] Confort set-point InputConfort Set-point2 Bytes9.1 temperature (°C)CWT
71[T3] Set-point InputSet-point2 Bytes9.1 temperature (°C)CWT
72[T3] Output HeatingOutput (% Proportional - Integral)1 Byte5.1 percentage (0..100%)CRWT
72[T3] Output HeatingOutput (2 points with Hysteresis)1 Bit1.1 switchCRWT
72[T3] OutputOutput (% Proportional - Integral)1 Byte5.1 percentage (0..100%)CRWT
72[T3] Output HeatingOutput (PWM Proportional - Integral)1 Bit1.1 switchCRWT
72[T3] OutputOutput (2 points with Hysteresis)1 Bit1.1 switchCRWT
72[T3] OutputOutput (PWM Proportional - Integral)1 Bit1.1 switchCRWT
73[T3] Output CoolingOutput (2 points with Hysteresis)1 Bit1.1 switchCRWT
73[T3] Output CoolingOutput (PWM Proportional - Integral)1 Bit1.1 switchCRWT
73[T3] Output CoolingOutput (% Proportional - Integral)1 Byte5.1 percentage (0..100%)CRWT
74[T3] Temperature Sensor 1Input Temperature Sensor 12 Bytes9.1 temperature (°C)CRWT
75[T3] Temperature Sensor 2Input Temperature Sensor 22 Bytes9.1 temperature (°C)CRWT
76[T3] Special mode Info2 Bytes mode Info2 Bytes22.101 RHCC statusCRWT
77[T3] Special mode Input 1 byte1 byte mode HVAC1 Byte20.102 HVAC modeCRWT
78[T3] Special mode Economic0=Off; 1=On1 Bit1.1 switchCRWT
79[T3] Special mode Stand-by0=Off; 1=On1 Bit1.1 switchCRWT
80[T3] Special mode Protection0=Off; 1=On1 Bit1.1 switchCRWT
81[T3] Special mode Confort0=Off; 1=On1 Bit1.1 switchCRWT
82[T3] Heating or Cooling mode Status0=Cooling; 1=Heating1 Bit1.1 switchCRWTU
83[T3] Heating or Cooling mode0=Cooling; 1=Heating1 Bit1.1 switchCRWTU
84[T3] Window alarm 10=No alarm; 1=Alarm1 Bit1.5 alarmCRWTU
85[T3] Window alarm 20=No alarm; 1=Alarm1 Bit1.5 alarmCRWTU
86[T3] Window alarm 30=No alarm; 1=Alarm1 Bit1.5 alarmCRWTU
87[T3] Window alarm 40=No alarm; 1=Alarm1 Bit1.5 alarmCRWTU
88[T4] On/Off (Status)1= On; 0= Off1 Bit1.1 switchCRWT
89[T4] On/Off1= On; 0= Off1 Bit1.1 switchCWT
90[T4] Set-point InformationCurrent Set-point2 Bytes9.1 temperature (°C)CRWT
91[T4] Confort set-point InputConfort Set-point2 Bytes9.1 temperature (°C)CWT
91[T4] Set-point InputSet-point2 Bytes9.1 temperature (°C)CWT
92[T4] Output HeatingOutput (% Proportional - Integral)1 Byte5.1 percentage (0..100%)CRWT
92[T4] Output HeatingOutput (2 points with Hysteresis)1 Bit1.1 switchCRWT
92[T4] Output HeatingOutput (PWM Proportional - Integral)1 Bit1.1 switchCRWT
92[T4] OutputOutput (% Proportional - Integral)1 Byte5.1 percentage (0..100%)CRWT
92[T4] OutputOutput (PWM Proportional - Integral)1 Bit1.1 switchCRWT
92[T4] OutputOutput (2 points with Hysteresis)1 Bit1.1 switchCRWT
93[T4] Output Cooling Output (2 points with Hysteresis)1 Bit1.1 switchCRWT
93[T4] Output Cooling Output (% Proportional - Integral)1 Byte5.1 percentage (0..100%)CRWT
93[T4] Output Cooling Output (PWM Proportional - Integral)1 Bit1.1 switchCRWT
94[T4] Temperature Sensor 1Input Temperature Sensor 12 Bytes9.1 temperature (°C)CRWT
95[T4] Temperature Sensor 2Input Temperature Sensor 22 Bytes9.1 temperature (°C)CRWTU
96[T4] Special mode Info2 Bytes mode Info2 Bytes22.101 RHCC statusCRWT
97[T4] Special mode Input 1 byte1 byte mode HVAC1 Byte20.102 HVAC modeCRWTU
98[T4] Special mode Economic0=Off; 1=On1 Bit1.1 switchCRWT
99[T4] Special mode Stand-by0=Off; 1=On1 Bit1.1 switchCRWT
100[T4] Special mode Protection0=Off; 1=On1 Bit1.1 switchCRWT
101[T4] Special mode Confort0=Off; 1=On1 Bit1.1 switchCRWT
102[T4] Heating or Cooling mode Status0=Cooling; 1=Heating1 Bit1.1 switchCRWTU
103[T4] Heating or Cooling mode0=Cooling; 1=Heating1 Bit1.1 switchCRWTU
104[T4] Window alarm 10=No alarm; 1=Alarm1 Bit1.5 alarmCRWTU
105[T4] Window alarm 20=No alarm; 1=Alarm1 Bit1.5 alarmCRWTU
106[T4] Window alarm 30=No alarm; 1=Alarm1 Bit1.5 alarmCRWTU
107[T4] Window alarm 40=No alarm; 1=Alarm1 Bit1.5 alarmCRWTU
108Output AStatus Switch A1 Bit1.1 switchCRT
109Output ASwitch A1 Bit1.1 switchCW
110Output APermanent ON A1 Bit1.1 switchCW
111Output ADisable Time function A1 Bit1.3 enableCW
112Output AChange Threshold value A1 Byte5.10 counter pulses (0..255)CW
112Output AChange Threshold value A2 Bytes7.1 pulsesCW
113Output AThreshold Input A1 Byte5.10 counter pulses (0..255)CW
113Output AThreshold Input A2 Bytes7.1 pulsesCW
114Output AForced Positioning A1 Bit1.3 enableCW
114Output AForced Positioning A2 Bit2.1 switch controlCW
115Output ALogical connection 1 A1 Bit1.2 booleanCW
116Output ALogical connection 2 A1 Bit1.2 booleanCW
117Output A8 Bit Scene A1 Byte18.1 scene controlCW
118Output ASet Preset 1/2 A1 Bit1.1 switchCW
119Output ACall preset 1/2 A1 Bit1.3 enableCW
120Output AWarning stair lighting A1 Bit1.1 switchCT
121Output ADuration of Staircase Light A2 Bytes7.5 time (s)CRW
122Output BStatus Switch B1 Bit1.1 switchCRT
123Output BSwitch B1 Bit1.1 switchCW
124Output BPermanent ON B1 Bit1.1 switchCW
125Output BDisable Time function B1 Bit1.3 enableCW
126Output BChange Threshold value B1 Byte5.10 counter pulses (0..255)CW
126Output BChange Threshold value B2 Bytes7.1 pulsesCW
127Output BThreshold Input B2 Bytes7.1 pulsesCW
127Output BThreshold Input B1 Byte5.10 counter pulses (0..255)CW
128Output BForced Positioning B2 Bit2.1 switch controlCW
128Output BForced Positioning B1 Bit1.3 enableCW
129Output BLogical connection 1 B1 Bit1.2 booleanCW
130Output BLogical connection 2 B1 Bit1.2 booleanCW
131Output B8 Bit Scene B1 Byte18.1 scene controlCW
132Output BSet Preset 1/2 B1 Bit1.1 switchCW
133Output BCall preset 1/2 B1 Bit1.3 enableCW
134Output BWarning stair lighting B1 Bit1.1 switchCT
135Output BDuration of Staircase Light B2 Bytes7.5 time (s)CW
136Roller controlRoller Move Up/Down1 Bit1.8 up/downCW
136Venting Louver controlLouver Move Up/Down1 Bit1.8 up/downCW
136Blind controlBlind Move Up/Down1 Bit1.8 up/downCW
137Roller controlRoller Stop - Step Up/down1 Bit1.7 stepCW
137Blind controlBlind Stop - Step Up/down1 Bit1.7 stepCW
137Venting Louver controlLouver Stop - Step Up/down1 Bit1.7 stepCW
138Forced InputForced object 2 Bit2.1 switch controlCW
139Wind alarmWind Alarm 1 Input 1 Bit1.5 alarmCW
140Rain AlarmRain Alarm Input1 Bit1.5 alarmCW
141SceneScene Input1 Byte18.1 scene controlCW
142Info MovementInfo movement Up/Down1 Bit1.8 up/downCT
143Wind alarmWind Alarm 2 Input1 Bit1.5 alarmCW
144Wind alarmWind Alarm 3 Input 1 Bit1.5 alarmCW
145Frost alarmFrost alarm Input1 Bit1.5 alarmCRWTU
146Roller positionRoller position object Input1 Byte5.1 percentage (0..100%)CRWTU
146Louver positionLouver position object Input1 Byte5.1 percentage (0..100%)CRWTU
146Blind positionBlind position object Input1 Byte5.1 percentage (0..100%)CRWTU
147Slats positionSlats position object Input1 Byte5.1 percentage (0..100%)CRWTU
148Info Blind positionBlind position object Info1 Byte5.1 percentage (0..100%)CT
148Info Roller positionRoller position object Info1 Byte5.1 percentage (0..100%)CT
148Info Louver positionLouver position object Info1 Byte5.1 percentage (0..100%)CT
149Info Slats positionSlats position object Info1 Byte5.1 percentage (0..100%)CT
150Solar protectionLux level object2 Bytes9.4 lux (Lux)CW
150Solar protectionObject (On/Off)1 Bit1.2 booleanCW
151Solar protectionPosition object 1 Byte5.1 percentage (0..100%)CW
Parameters (244)
ParameterTypeDefault
RASTROETSunsignedInt 0…255112
Function of Channel 1listNot assigned
Debounce timelist10mSec.
Distinction between Short and Long actionlistNo
Contact typelistNormally Open
Long action after...list0.3 Sec.
Number of objects for Short/Long operationlist1
Short actionlistOn
Long actionlistOn
Cyclic transmission?listNo
Action after Closing the contactlistOn
Action after Opening the contactlistOn
Transmit state on bus voltage recovery?listNo
Actiafter after Closing the contactlistOn
Cycle base timelist1 Sec.
Factor (Total time = Base x Factor)unsignedInt 0…2557
Dimming functionality?listDimming and Switch
Action after operationlistBrighter/Darker
Actiafter after Long operationlistBrighter/Darker
Save Scene on Long operation?listNo
Maximum time between two operationslist0.5 Sec.
Number of operationslist2
Switch 1 operationlistOn
Switch 2 operationlistOn
Switch 3 operationlistOn
Switch 4 operationlistOn
Number of objectslist2
Functional constructionlist1 Pushbutton
Shutter functionalitylistShort=Step, Long=Move
Actiafter after Long operationlistMove Up
Action after Short operationlistStep Down
Value type on Short operationlist1 Bit
Value type on Long operationlist1 Bit
Signlist+
Integer partunsignedInt 0…990
Decimal partunsignedInt 0…990
2 Bytes valueunsignedInt 0…655350
2 Bytes signed valuesignedInt -32768…327670
4 Bytes valueunsignedInt 0…42949672950
Bit valuelist0
2 Bits valuelist0
1 Byte valueunsignedInt 0…2550
Value type on operationlist1 Bit
Type of Scene controllist8 Bit scene
Scene numberunsignedInt 1…641
Action after Short operationlistRecall
Store ScenelistNo
Scene number 1/2?unsignedInt 1…21
Data counter widthlist8
Start value (0-255)unsignedInt 0…2550
Start value (0-65535)unsignedInt 0…655350
Start value (0-4.294.967.295)unsignedInt 0…42949672950
Temperature value base timelist1 Min.
Temperature variation to sendunsignedInt 5…2005
Protection alarmslistNo protection
HysteresisunsignedInt 0…500
Over-heating Temperaturelist-30
Over-cooling Temperaturelist-30
"Temperature functionality" enabled after bus recovery voltage?listNo
Temperature Sensor calibration valuelist0
Function of Channel 2listNot assigned
Action after Opening contactlistOn
Function of Channel 3listNot assigned
Function of Channel 4listNot assigned
Enable Thermostat functionality?listNo
ModelistCooling Thermostat
Reference Temperature SourcelistOne source
Thermostat always on?listNo
State after bus recovery voltagelistOff
Enable turn-on Thermostat when Special command arrives?listEnable
Send Thermostat Set-point after bus recovery voltage?listNo
Enable automatic mode change?listEnable
Mode after bus recovery voltagelistCooling Thermostat
Control objectlistDifferent objects for heating and cooling
Set-point modelistAbsolute Set-point mode
Initial Confort Set-point after bus recovery voltageunsignedInt 5…4524
Save Set-point after mode change via object?listNo
Mode after bus recovery voltagelistConfort
Enable 1 bit mode objects?listDisable
Enable Window protectionlistEnable
Confort mode Set-pointunsignedInt 5…4522
Offset for Stand-by Set-point modelist-100
Offset for Economic Set-point modelist-100
Set-point for protection from FreezingunsignedInt 0…158
Confort mode Set-pointunsignedInt 5…455
Offset for Stand-by Set-point modeunsignedInt 0…9964
Offset for Economic Set-point modeunsignedInt 0…9996
Over-temperature protection Set-pointunsignedInt 30…4540
Regulation modelistTwo points with Hysteresis control
Upper HysteresisunsignedInt 5…4510
Lower HysteresisunsignedInt 5…4510
Forward period (0=Disable)unsignedInt 0…2550
PWM typelistPWM (1 bit)
PI cycle timeunsignedInt 0…255255
Proportional bandunsignedInt 0…155
Attenuation factorunsignedInt 0…9931
Maximum Integral component (%)unsignedInt 0…9921
Initial Set-point after bus recovery voltageunsignedInt 5…4524
Save set point after mode change via object?listNo
Transmission and Switching delay after recovery of bus voltage (2..255s)unsignedInt 2…2552
Operating mode?list2-channel Switch Actuator
RASTROETSunsignedInt 0…25516
Status response of Switching statelistNo
Object value switching statuslistClosed=1, Open=0
Reaction after bus faillistOpen contact
Object "Switch" value after bus recovery voltagelistSet object to "0"
Output polaritylistNormally open contact
Enable Time functionslistNo
Time functionlistStaircase light time switch
Value object "Disable time function" after bus recovery voltagelist"0": Enable time functions
Enable Preset functionlistNo
Enable Scene (8 bits) functionslistNo
Enable Logic functionlistNo
Enable "Forced" functionlistNo
Enable "Threshold" functionlistNo
Staircase light time switch timing (Sec.)unsignedInt 0…655350
Timer is retriggerable?listNo
Staircase ligh time switch can be switched off?listON with "1", OFF with "0"
Warning before end of time?listNo
Warning time to add in Sec.unsignedInt 0…6553516
Staircase time changed via object?listNo
On delay time (Sec.)unsignedInt 0…655351
Off delay time (Sec.)unsignedInt 0…655351
Flashing when object "Switch" islistOn (1)
Flash On time (Sec.)unsignedInt 0…655355
Flash Off time (Sec.)unsignedInt 0…655355
Reaction on Preset 1 (telegram 0)listNo reaction
Reaction on Preset 2 (telegram 1)listNo reaction
Preset can be set via bus?listNo
Scene 1 numberlistScene 1
Scene 1 Preset valuelistOff
Scene 2 numberlistScene 2
Scene 2 Preset ValuelistOff
Scene 3 numberlistScene 3
Scene 3 Preset ValuelistOff
Scene 4 numberlistScene 4
Scene 4 Preset ValuelistOff
Scene 5 numberlistScene 5
Scene 5 Preset ValuelistOff
Logical connection 1listEnable
Logical connection 1 functionlistAND
Logical connection 1 invertedlistNo
Object value "Logical connection 1" after bus recovery voltagelistOn
Logical connection 2listDisable
Logical connection 2 functionlistAND
Logical connection 2 invertedlistNo
Object value "Logical connection 2" after bus recovery voltagelistOff
Object "Forced" typelist1 bit object
Object "Forced" polaritylistObject forced "1" --> Switch Off
Object "Forced" state after bus recovery voltagelistNot Forced
Data type of object "Threshold Input"list1 byte (0..255)
Change Threshold value 1 over the bus?listNo
Threshold value 1 (0..255)unsignedInt 0…255255
Threshold value 2 (0..255)unsignedInt 0…2550
Threshold value 1 (0..65535)unsignedInt 0…6553550001
Threshold value 2 (0..65535)unsignedInt 0…6553514592
Threshold values define Hysteresis?listNo
Threshold value after bus recovery voltageunsignedInt 0…255122
Threshold value after bus recovery voltageunsignedInt 0…6553517408
Object value < Threshold value 1listNo reaction
Object value > Threshold value 2listOn (1)
Value 1 <= Object value <= Value 2listNo reaction
Object value > Threshold value 2listNo reaction
Type of devicelistVenecian Blind
Reaction after bus faillistStop
Behaviour after bus recovery voltagelistNo action
Roller position (0-100%) after bus recovery voltageunsignedInt 0…1000
Position Slats (0-100%) after bus recovery voltageunsignedInt 0…1000
Extra time for "Up" movement (%)unsignedInt 0…300
Forced vs Weather alarm Prioritylist1.-Forced operation 2.-Weather alarm
Reversion Pause Time (msec)unsignedInt 499…5000500
Step operation possiblelistNo (only Stop)
Step time duration (tenths of a second)unsignedInt 2…60010
Blind movement time duration (Sec.)unsignedInt 1…36001
Slats movement time duration (tenths of a second)unsignedInt 2…60020
Time to send "Current position" (Sec.)unsignedInt 60…360060
Time to send "Slats position" (Sec.)unsignedInt 60…360060
Enable object "Movement Info"listNo
Enable Security features?listNo
Enable object "Wind Alarm 1"listNo
Enable object "Wind Alarm 2"listNo
Enable object "Wind Alarm 3"listNo
Enable object "Rain Alarm"listNo
Enable object "Frost alarm"listNo
Enable Wind alarm Watchdog?listNo
Watchdog Wind alarm time (Sec.)unsignedInt 10…655353600
Enable Rain Alarm Watchdog?listNo
Rain alarm Watchdog time (Sec.)unsignedInt 10…6553510
Enable Frost alarm Watchdog?listNo
Frost alarm Watchdog time (Sec.)unsignedInt 10…6553510
Response to alarm?listNo action
Behaviour at the end of the Wind alarmlistNo action
Response to Rain alarm?listNo action
Behaviour at the end of the Rain alarmlistNo action
Response to Frost alarm?listNo action
Behaviour at the end of the Frost alarmlistNo action
Weather Alarms prioritylistWind --> Rain --> Frost
Enable Sun protection?listNo
Protection object typelist1 Bit On/Off protection object
Solar protection object polaritylist"1": Sun protection On
Lux value to initiate protectionunsignedInt 1…36001000
Lux value to end protectionunsignedInt 1…3600500
Delay time to initiate Solar protection (Sec.)unsignedInt 1…36001
Solar protection ON actionlistNo action
Scene numberlistScene 1
Position (%)unsignedInt 0…1000
Slats position (%)unsignedInt 0…1000
Delay time to end Solar protection (Sec.)unsignedInt 1…36001
Solar protection end actionlistNo action
Enable Scene functionality?listNo
Scene 1 Position (%)unsignedInt 0…1000
Scene 2 Position (%)unsignedInt 0…1000
Scene 3 Position (%)unsignedInt 0…1000
Scene 4 Position (%)unsignedInt 0…1000
Scene 5 Position (%)unsignedInt 0…1000
Scene 6 numberlistScene 6
Scene 6 Position (%)unsignedInt 0…1000
Scene 7 numberlistScene 7
Scene 7 Position (%)unsignedInt 0…1000
Scene 8 numberlistScene 8
Scene 8 position (%)unsignedInt 0…1000
Scene 1 Position Slats (%)unsignedInt 0…1000
Scene 2 Position Slats (%)unsignedInt 0…1000
Scene 3 Position Slats (%)unsignedInt 0…1000
Scene 4 Position Slats (%)unsignedInt 0…1000
Scene 5 Position Slats (%)unsignedInt 0…1000
Scene 6 Position Slats (%)unsignedInt 0…1000
Scene 7 Position Slats (%)unsignedInt 0…1000
Scene 8 position slats (%)unsignedInt 0…1000
Enable Forced function?listNo
Forced state after bus recovery voltagelistNot Forced
Fabric tensioning time (Sec.)unsignedInt 0…2550
Enable object "Info position Roller %"?listNo
Enable object "Info position Slats %"?listNo
Factor time to send temperature (Total time = Base x Factor) (0=Disable send)unsignedInt 0…2557
Action after operationlistMove Up
Save Offset after mode change via object?listNo
Save offset after mode change via object?listNo
Venting Louver position (0-100%) after bus recovery voltageunsignedInt 0…1000
Blind position (0-100%) after bus recovery voltageunsignedInt 0…1000
Louver movement time duration (Sec.)unsignedInt 1…36001
Roller movement Time duration (Sec.)unsignedInt 1…36001
Enable object "Info position Blind %"?listNo
Enable object "Info position Louver %"?listNo

Version history

ApplicationApp noFingerprintFirst seenSizeFile
DINUY Actuator 2-channel Switch/Blinds 0.0 latest$20011FEE2026-11-25175 KBDownload

About this file

This is the official ETS product database for the Dinuy Actuator 2 ch Switch/Blind (PE KNT 001), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.