KNX Database
Dinuy IR KNT 044 Act 4ch/2ch switch/blind + RGBW dimmer + inputs

Act 4ch/2ch switch/blind + RGBW dimmer + inputs IR KNT 044

Dinuy · Order number IR KNT 044 · KNX-TP Devices › Actuators › Dimming Actuators

Download .knxprod DINUY_IRKNT044 0.0 · 645 KB

Product

ManufacturerDinuy
Product nameAct 4ch/2ch switch/blind + RGBW dimmer + inputs
Order numberIR KNT 044
Product text4ch/2ch Switch/Blind + 4ch RGBW Dimming Actuator
HardwareAct 4ch/2ch switch/blind + RGBW dimmer + inputs
MediumTwisted Pair
Bus current (mA)10
Rail mountedNo
RegistrationCertified · 2021-11-10
Languageses-ES, en-GB, en, en-US
Catalog entryM-009A_H-IRKNT044271020-0_HP-200F-00-1CE1_CI-IR.20KNT.20044-1
Fingerprint1CE1
SHA-256d007893c8b8c2fbddcd648f654f7d63692dffa739b6bb26c91d60fae1d66a140
First seen2026-11-25
Markets68 markets

Application program: DINUY_IRKNT044 0.0

Application number$200F
Version0.0
Mask versionMV-07B0 (System B)
KNX Data SecureNo
Minimum ETS version5.0
Parameters3290
Group objects1212
Group objects (1212)
NoNameFunctionSizeDPTFlags
1[Central] Switch / Move Blind / Dim Control / Fan-CoilOn/Off, Up/Down1 Bit1.1 switchCW
1[Central] SwitchOn/Off1 Bit1.1 switchCW
2[Central] Move BlindUp / Down / Position1 Bit1.1 switchCW
3[Central] Dimming ControlDim Brighter / Darker1 Bit1.1 switchCW
4CENTRAL_FANCOILCENTRAL_FANCOIL1 BitDPT.1CW
5[Out A1] Switch Feedback1 = On, 0 = Off1 Bit1.1 switchCRT
6[Out A1] Switch On/Off1 = On, 0 = Off1 Bit1.1 switchCW
7[Out A1] Permanent ON1 = On, 0 = Off1 Bit1.1 switchCW
8[Out A1] Disable Time Function1 = Disable, 0 = Enable1 Bit1.3 enableCW
9[Out A1] Change Threshold 11 Byte value1 Byte5.10 counter pulses (0..255)CW
9[Out A1] Change Threshold 12 Bytes value2 Bytes7.1 pulsesCW
10[Out A1] Threshold Input1 Byte value1 Byte5.10 counter pulses (0..255)CW
10[Out A1] Threshold Input2 Bytes value2 Bytes7.1 pulsesCW
11[Out A1] Forced 2 Bits2 Bits value2 Bit2.1 switch controlCW
11[Out A1] Forced 1 Bit1 = Forced, 0 = Not Forced1 Bit1.1 switchCW
12[Out A1] Logical connection 11 = True, 0 = False1 Bit1.2 booleanCW
13[Out A1] Logical connection 21 = True, 0 = False1 Bit1.2 booleanCW
14[Out A1] Scene Scene Control1 Byte18.1 scene controlCW
15[Out A1] Set Preset 1/2Telegram 0 --> Set Preset 1, Telegram 1 --> Set Preset 21 Bit1.1 switchCW
16[Out A1] Call Preset 1/2Telegram 0 --> Call Preset 1, Telegram 1 --> Call Preset 21 Bit1.3 enableCW
17[Out A1] Staircase lighting Pre-warning1 = Pre-warning, 0 = No Pre-warning1 Bit1.1 switchCRT
18[Out A1] Staircase Time (sec)2 Bytes value2 Bytes7.5 time (s)CW
19[Out A1] Time Switch1 = Timer On1 Bit1.10 start/stopCW
20[Out A2] Switch Feedback1 = On, 0 = Off1 Bit1.1 switchCRT
21[Out A2] Switch On/Off1 = On, 0 = Off1 Bit1.1 switchCW
22[Out A2] Permanent ON1 = On, 0 = Off1 Bit1.1 switchCW
23[Out A2] Disable Time Function1 = Disable, 0 = Enable1 Bit1.3 enableCW
24[Out A2] Change Threshold 11 Byte value1 Byte5.10 counter pulses (0..255)CW
24[Out A2] Change Threshold 12 Bytes value2 Bytes7.1 pulsesCW
25[Out A2] Threshold Input1 Byte value1 Byte5.10 counter pulses (0..255)CW
25[Out A2] Threshold Input2 Bytes value2 Bytes7.1 pulsesCW
26[Out A2] Forced 1 Bit1 = Forced, 0 = Not Forced1 Bit1.1 switchCW
26[Out A2] Forced 2 Bits2 Bits value2 Bit2.1 switch controlCW
27[Out A2] Logical connection 11 = True, 0 = False1 Bit1.2 booleanCW
28[Out A2] Logical connection 21 = True, 0 = False1 Bit1.2 booleanCW
29[Out A2] Scene Scene Control1 Byte18.1 scene controlCW
30[Out A2] Set Preset 1/2Telegram 0 --> Set Preset 1, Telegram 1 --> Set Preset 21 Bit1.1 switchCW
31[Out A2] Call Preset 1/2Telegram 0 --> Call Preset 1, Telegram 1 --> Call Preset 21 Bit1.3 enableCW
32[Out A2] Staircase lighting Pre-warning1 = Pre-warning, 0 = No Pre-warning1 Bit1.1 switchCRT
33[Out A2] Staircase Time (sec)2 Bytes value2 Bytes7.5 time (s)CW
34[Out A2] Time Switch1 = Timer On1 Bit1.10 start/stopCW
35[Out B1] Switch Feedback1 = On, 0 = Off1 Bit1.1 switchCRT
36[Out B1] Switch On/Off1 = On, 0 = Off1 Bit1.1 switchCW
37[Out B1] Permanent ON1 = On, 0 = Off1 Bit1.1 switchCW
38[Out B1] Disable Time Function1 = Disable, 0 = Enable1 Bit1.3 enableCW
39[Out B1] Change Threshold 11 Byte value1 Byte5.10 counter pulses (0..255)CW
39[Out B1] Change Threshold 12 Bytes value2 Bytes7.1 pulsesCW
40[Out B1] Threshold Input1 Byte value1 Byte5.10 counter pulses (0..255)CW
40[Out B1] Threshold Input2 Bytes value2 Bytes7.1 pulsesCW
41[Out B1] Forced 1 Bit1 = Forced, 0 = Not Forced1 Bit1.1 switchCW
41[Out B1] Forced 2 Bits2 Bits value2 Bit2.1 switch controlCW
42[Out B1] Logical connection 11 = True, 0 = False1 Bit1.2 booleanCW
43[Out B1] Logical connection 21 = True, 0 = False1 Bit1.2 booleanCW
44[Out B1] Scene Scene Control1 Byte18.1 scene controlCW
45[Out B1] Set Preset 1/2Telegram 0 --> Set Preset 1, Telegram 1 --> Set Preset 21 Bit1.1 switchCW
46[Out B1] Call Preset 1/2Telegram 0 --> Call Preset 1, Telegram 1 --> Call Preset 21 Bit1.3 enableCW
47[Out B1] Staircase lighting Pre-warning1 = Pre-warning, 0 = No Pre-warning1 Bit1.1 switchCRT
48[Out B1] Staircase Time (sec)2 Bytes value2 Bytes7.5 time (s)CW
49[Out B1] Time Switch1 = Timer On1 Bit1.10 start/stopCW
50[Out B2] Switch Feedback1 = On, 0 = Off1 Bit1.1 switchCRT
51[Out B2] Switch On/Off1 = On, 0 = Off1 Bit1.1 switchCW
52[Out B2] Permanent ON1 = On, 0 = Off1 Bit1.1 switchCW
53[Out B2] Disable Time Function1 = Disable, 0 = Enable1 Bit1.3 enableCW
54[Out B2] Change Threshold 11 Byte value1 Byte5.10 counter pulses (0..255)CW
54[Out B2] Change Threshold 12 Bytes value2 Bytes7.1 pulsesCW
55[Out B2] Threshold Input1 Byte value1 Byte5.10 counter pulses (0..255)CW
55[Out B2] Threshold Input2 Bytes value2 Bytes7.1 pulsesCW
56[Out B2] Forced 1 Bit1 = Forced, 0 = Not Forced1 Bit1.1 switchCW
56[Out B2] Forced 2 Bits2 Bits value2 Bit2.1 switch controlCW
57[Out B2] Logical connection 11 = True, 0 = False1 Bit1.2 booleanCW
58[Out B2] Logical connection 21 = True, 0 = False1 Bit1.2 booleanCW
59[Out B2] Scene Scene Control1 Byte18.1 scene controlCW
60[Out B2] Set Preset 1/2Telegram 0 --> Set Preset 1, Telegram 1 --> Set Preset 21 Bit1.1 switchCW
61[Out B2] Call Preset 1/2Telegram 0 --> Call Preset 1, Telegram 1 --> Call Preset 21 Bit1.3 enableCW
62[Out B2] Staircase lighting Pre-warning1 = Pre-warning, 0 = No Pre-warning1 Bit1.1 switchCRT
63[Out B2] Staircase Time (sec)2 Bytes value2 Bytes7.5 time (s)CW
64[Out B2] Time Switch1 = Timer On1 Bit1.10 start/stopCW
65[BL A] Louver Move Up/Down0 = Up, 1 = Down1 Bit1.8 up/downCW
65[BL A] Roller Move Up/Down0 = Up, 1 = Down1 Bit1.8 up/downCW
65[BL A] Blind Move Up/Down0 = Up, 1 = Down1 Bit1.8 up/downCW
66[BL A] Blind Stop / Step Up/Down0 = Step Up, 1 = Step Down1 Bit1.7 stepCW
66[BL A] Roller Stop / Step Up/Down0 = Step Up, 1 = Step Down1 Bit1.7 stepCW
66[BL A] Louver Stop / Step Up/Down0 = Step Up, 1 = Step Down1 Bit1.7 stepCW
67[BL A] Forced Input2 Bits control2 Bit2.1 switch controlCW
68[BL A] Wind Alarm 11 = Alarm, 0 = No Alarm1 Bit1.5 alarmCW
69[BL A] Wind Alarm 21 = Alarm, 0 = No Alarm1 Bit1.5 alarmCW
70[BL A] Wind Alarm 31 = Alarm, 0 = No Alarm1 Bit1.5 alarmCW
71[BL A] Rain Alarm1 = Alarm, 0 = No Alarm1 Bit1.5 alarmCW
72[BL A] Frost Alarm1 = Alarm, 0 = No Alarm1 Bit1.5 alarmCW
73[BL A] Scene InputScene Control1 Byte18.1 scene controlCW
74[BL A] Movement Feedback0 = Up, 1 = Down1 Bit1.8 up/downCRT
75[BL A] Blind position Input0% = Open, 100% = Closed1 Byte5.1 percentage (0..100%)CW
75[BL A] Louver position Input0% = Open, 100% = Closed1 Byte5.1 percentage (0..100%)CW
75[BL A] Roller position Input0% = Open, 100% = Closed1 Byte5.1 percentage (0..100%)CW
76[BL A] Slats position Input0% = Open, 100% = Closed1 Byte5.1 percentage (0..100%)CW
77[BL A] Louver position Feedback0% = Open, 100% = Closed1 Byte5.1 percentage (0..100%)CRT
77[BL A] Blind position Feedback0% = Open, 100% = Closed1 Byte5.1 percentage (0..100%)CRT
77[BL A] Roller position Feedback0% = Open, 100% = Closed1 Byte5.1 percentage (0..100%)CRT
78[BL A] Slats position Feedback0% = Open, 100% = Closed1 Byte5.1 percentage (0..100%)CRT
79[BL A] Sun Protection Input1 = On, 0 = Off1 Bit1.1 switchCW
79[BL A] Lux level InputLux value2 Bytes9.4 lux (Lux)CW
80[BL A] Sun Protection position Input0% = Open, 100% = Closed1 Byte5.1 percentage (0..100%)CW
81[BL B] Blind Move Up/Down0 = Up, 1 = Down1 Bit1.8 up/downCW
81[BL B] Roller Move Up/Down0 = Up, 1 = Down1 Bit1.8 up/downCW
81[BL B] Louver Move Up/Down0 = Up, 1 = Down1 Bit1.8 up/downCW
82[BL B] Blind Stop / Step Up/Down0 = Step Up, 1 = Step Down1 Bit1.7 stepCW
82[BL B] Roller Stop / Step Up/Down0 = Step Up, 1 = Step Down1 Bit1.7 stepCW
82[BL B] Louver Stop / Step Up/Down0 = Step Up, 1 = Step Down1 Bit1.7 stepCW
83[BL B] Forced Input2 Bits control2 Bit2.1 switch controlCW
84[BL B] Wind Alarm 11 = Alarm, 0 = No Alarm1 Bit1.5 alarmCW
85[BL B] Wind Alarm 21 = Alarm, 0 = No Alarm1 Bit1.5 alarmCW
86[BL B] Wind Alarm 31 = Alarm, 0 = No Alarm1 Bit1.5 alarmCW
87[BL B] Rain Alarm 1 = Alarm, 0 = No Alarm1 Bit1.5 alarmCW
88[BL B] Frost Alarm1 = Alarm, 0 = No Alarm1 Bit1.5 alarmCW
89[BL B] Scene InputScene Control1 Byte18.1 scene controlCW
90[BL B] Movement Feedback0 = Up, 1 = Down1 Bit1.8 up/downCRT
91[BL B] Blind position Input0% = Open, 100% = Closed1 Byte5.1 percentage (0..100%)CW
91[BL B] Roller position Input0% = Open, 100% = Closed1 Byte5.1 percentage (0..100%)CW
91[BL B] Louver position Input0% = Open, 100% = Closed1 Byte5.1 percentage (0..100%)CW
92[BL B] Slats position Input0% = Open, 100% = Closed1 Byte5.1 percentage (0..100%)CW
93[BL B] Blind position Feedback0% = Open, 100% = Closed1 Byte5.1 percentage (0..100%)CRT
93[BL B] Roller position Feedback0% = Open, 100% = Closed1 Byte5.1 percentage (0..100%)CRT
93[BL B] Louver position Feedback0% = Open, 100% = Closed1 Byte5.1 percentage (0..100%)CRT
94[BL B] Slats position Feedback0% = Open, 100% = Closed1 Byte5.1 percentage (0..100%)CRT
95[BL B] Sun Protection Input1 = On, 0 = Off1 Bit1.1 switchCW
95[BL B] Lux level InputLux value2 Bytes9.4 lux (Lux)CW
96[BL B] Sun Protection position Input0% = Open, 100% = Closed1 Byte5.1 percentage (0..100%)CW
100[R] Switch On/Off Input1 = On, 0= Off1 Bit1.1 switchCW
101[R] Relative Set value control InputDimming control4 Bit3.7 dimming controlCW
101[RGB R] Relative Set value control InputR Dimming4 Bit3.7 dimming controlCW
102[R] Absolute Set value control Input0 - 100%1 Byte5.1 percentage (0..100%)CW
103[R] Timed Start-Stop Input1 = Start; 0 = Stop1 Bit1.10 start/stopCW
104[R] Forced InputForced Control2 Bit2.1 switch controlCW
105[R] Scene InputScene control1 Byte18.1 scene controlCW
106[R] Switch On-Off Feedback1 = On, 0 = Off1 Bit1.1 switchCRT
107[R] Dimming Value Feedback0 - 100%1 Byte5.1 percentage (0..100%)CRT
108[R] Dimming Speed (from 1% to 100%)100 msec units2 Bytes7.4 time (100 ms)CW
109[R] Lock Channel Input1 = Lock, 0 = Unlock1 Bit1.3 enableCW
110[R] Sequential Operation1 = On, 0 = Off1 Bit1.1 switchCW
111[R] Sequential Operation Feedback1 = On, 0 = Off1 Bit1.1 switchCRT
112[R] Overload alarm1 = Overload1 Bit1.5 alarmCRT
113GODUMMY1_0GODUMMY1_04 BytesDPT.12CWT
114GODUMMY2_0GODUMMY2_04 BytesDPT.12CWT
115GODUMMY3_0GODUMMY3_04 BytesDPT.12CWT
116GODUMMY4_0GODUMMY4_04 BytesDPT.12CWT
117GODUMMY5_0GODUMMY5_04 BytesDPT.12CWT
118GODUMMY6_0GODUMMY6_04 BytesDPT.12CWT
119GODUMMY7_0GODUMMY7_04 BytesDPT.12CWT
120GODUMMY8_0GODUMMY8_04 BytesDPT.12CWT
121GODUMMY9_0GODUMMY9_04 BytesDPT.12CWT
122GODUMMY10_0GODUMMY10_04 BytesDPT.12CWT
123[G] Switch On/Off Input1 = On, 0= Off1 Bit1.1 switchCW
124[G] Relative Set value control InputDimming control4 Bit3.7 dimming controlCW
124[RGB G] Relative Set value control InputG Dimming4 Bit3.7 dimming controlCW
125[G] Absolute Set value control Input0 - 100%1 Byte5.1 percentage (0..100%)CW
126[G] Timed Start-Stop Input1 = Start; 0 = Stop1 Bit1.10 start/stopCW
127[G] Forced InputForced Control2 Bit2.1 switch controlCW
128[G] Scene InputScene control1 Byte18.1 scene controlCW
129[G] Switch On-Off Feedback1 = On, 0 = Off1 Bit1.1 switchCRT
130[G] Dimming Value Feedback0 - 100%1 Byte5.1 percentage (0..100%)CRT
131[G] Dimming Speed (from 1% to 100%)100 msec units2 Bytes7.4 time (100 ms)CW
132[G] Lock Channel Input1 = Lock, 0 = Unlock1 Bit1.3 enableCW
133[G] Sequential Operation1 = On, 0 = Off1 Bit1.1 switchCW
134[G] Sequential Operation Feedback1 = On, 0 = Off1 Bit1.1 switchCRT
135[G] Overload alarm1 = Overload1 Bit1.5 alarmCRT
136GODUMMY1_1GODUMMY1_14 BytesDPT.12CWT
137GODUMMY2_1GODUMMY2_14 BytesDPT.12CWT
138GODUMMY3_1GODUMMY3_14 BytesDPT.12CWT
139GODUMMY4_1GODUMMY4_14 BytesDPT.12CWT
140GODUMMY5_1GODUMMY5_14 BytesDPT.12CWT
141GODUMMY6_1GODUMMY6_14 BytesDPT.12CWT
142GODUMMY7_1GODUMMY7_14 BytesDPT.12CWT
143GODUMMY8_1GODUMMY8_14 BytesDPT.12CWT
144GODUMMY9_1GODUMMY9_14 BytesDPT.12CWT
145GODUMMY10_1GODUMMY10_14 BytesDPT.12CWT
146[B] Switch On/Off Input1 = On, 0= Off1 Bit1.1 switchCW
147[B] Relative Set value control InputDimming control4 Bit3.7 dimming controlCW
147[RGB B] Relative Set value control InputB Dimming4 Bit3.7 dimming controlCW
148[B] Absolute Set value control Input0 - 100%1 Byte5.1 percentage (0..100%)CW
149[B] Timed Start-Stop Input1 = Start; 0 = Stop1 Bit1.10 start/stopCW
150[B] Forced InputForced Control2 Bit2.1 switch controlCW
151[B] Scene InputScene control1 Byte18.1 scene controlCW
152[B] Switch On-Off Feedback1 = On, 0 = Off1 Bit1.1 switchCRT
153[B] Dimming Value Feedback0 - 100%1 Byte5.1 percentage (0..100%)CRT
154[B] Dimming Speed (from 1% to 100%)100 msec units2 Bytes7.4 time (100 ms)CW
155[B] Lock Channel Input1 = Lock, 0 = Unlock1 Bit1.3 enableCW
156[B] Sequential Operation1 = On, 0 = Off1 Bit1.1 switchCW
157[B] Sequential Operation Feedback1 = On, 0 = Off1 Bit1.1 switchCRT
158[B] Overload Alarm1 = Overload1 Bit1.5 alarmCRT
159GODUMMY1_2GODUMMY1_24 BytesDPT.12CWT
160GODUMMY2_2GODUMMY2_24 BytesDPT.12CWT
161GODUMMY3_2GODUMMY3_24 BytesDPT.12CWT
162GODUMMY4_2GODUMMY4_24 BytesDPT.12CWT
163GODUMMY5_2GODUMMY5_24 BytesDPT.12CWT
164GODUMMY6_2GODUMMY6_24 BytesDPT.12CWT
165GODUMMY7_2GODUMMY7_24 BytesDPT.12CWT
166GODUMMY8_2GODUMMY8_24 BytesDPT.12CWT
167GODUMMY9_2GODUMMY9_24 BytesDPT.12CWT
168GODUMMY10_2GODUMMY10_24 BytesDPT.12CWT
169[W] Switch On/Off Input1 = On, 0= Off1 Bit1.1 switchCW
170[W] Relative Set value control InputDimming control4 Bit3.7 dimming controlCW
170[RGB W] Relative Set value control InputW Dimming4 Bit3.7 dimming controlCW
171[W] Absolute Set value control Input0 - 100%1 Byte5.1 percentage (0..100%)CW
172[W] Timed Start-Stop Input1 = Start; 0 = Stop1 Bit1.10 start/stopCW
173[W] Forced InputForced Control2 Bit2.1 switch controlCW
174[W] Scene InputScene control1 Byte18.1 scene controlCW
175[W] Switch On-Off Feedback1 = On, 0 = Off1 Bit1.1 switchCRT
176[W] Dimming Value Feedback0 - 100%1 Byte5.1 percentage (0..100%)CRT
177[W] Dimming Speed (from 1% to 100%)100 msec units2 Bytes7.4 time (100 ms)CW
178[W] Lock Channel Input1 = Lock, 0 = Unlock1 Bit1.3 enableCW
179[W] Sequential Operation1 = On, 0 = Off1 Bit1.1 switchCW
180[W] Sequential Operation Feedback1 = On, 0 = Off1 Bit1.1 switchCRT
181[W] Overload alarm1 = Overload1 Bit1.5 alarmCRT
182GODUMMY1_3GODUMMY1_04 BytesDPT.12CWT
183GODUMMY2_3GODUMMY2_04 BytesDPT.12CWT
184GODUMMY3_3GODUMMY3_04 BytesDPT.12CWT
185GODUMMY4_3GODUMMY4_04 BytesDPT.12CWT
186GODUMMY5_3GODUMMY5_04 BytesDPT.12CWT
187GODUMMY6_3GODUMMY6_04 BytesDPT.12CWT
188GODUMMY7_3GODUMMY7_04 BytesDPT.12CWT
189GODUMMY8_3GODUMMY8_04 BytesDPT.12CWT
190GODUMMY9_3GODUMMY9_04 BytesDPT.12CWT
191GODUMMY10_3GODUMMY10_04 BytesDPT.12CWT
192[RGB] Switch On-Off Input1 = On, 0= Off1 Bit1.1 switchCW
192[RGBW] Switch On-Off Input1 = On, 0= Off1 Bit1.1 switchCW
193[RGB] RGB Colour InputRGB colour 3x(0..255)3 Bytes232.600 RGB value 3x(0..255)CW
193[RGBW] RGB Colour InputRGB colour 3x(0..255)3 Bytes232.600 RGB value 3x(0..255)CW
194[RGB] Relative Set value control InputRGB Dimming control (4 Bits)4 Bit3.7 dimming controlCW
194[RGBW] Relative Set value control InputDimming control (4 Bits)4 Bit3.7 dimming controlCW
195[RGB] Absolute Set value control Input 0 - 100%1 Byte5.1 percentage (0..100%)CW
195[RGBW] Absolute Set value control Input0 - 100%1 Byte5.1 percentage (0..100%)CW
196[RGB] Timed Start-Stop Input1 = Start; 0 = Stop1 Bit1.10 start/stopCW
196[RGBW] Timed Start-Stop Input1 = Start; 0 = Stop1 Bit1.10 start/stopCW
197[RGB] Forced InputForced Control2 Bit2.1 switch controlCW
197[RGBW] Forced InputForced Control2 Bit2.1 switch controlCW
198[RGB] Scene InputScene control1 Byte18.1 scene controlCW
198[RGBW] Scene InputScene control1 Byte18.1 scene controlCW
199[RGB] Switch On-Off Feedback1 = On, 0 = Off1 Bit1.1 switchCRT
199[RGBW] Switch On-Off Feedback1 = On, 0 = Off1 Bit1.1 switchCRT
200[RGB] RGB Colour FeedbackRGB current colour 3x(0..255)3 Bytes232.600 RGB value 3x(0..255)CRT
200[RGBW] RGB Colour FeedbackRGB current colour 3x(0..255)3 Bytes232.600 RGB value 3x(0..255)CRT
201[RGB] Dimming Speed (from 1% to 100%)100 msec units2 Bytes7.4 time (100 ms)CW
201[RGBW] Dimming Speed (from 1% to 100%)100 msec units2 Bytes7.4 time (100 ms)CW
202[RGB] Overload alarm1 = Overload; 0 = No Overload1 Bit1.5 alarmCRT
202[RGBW] Overload alarm1 = Overload; 0 = No Overload1 Bit1.5 alarmCRT
203[RGB] Dimming Value Feedback0 - 100%1 Byte5.1 percentage (0..100%)CRT
203[RGBW] Dimming Value Feedback0 - 100%1 Byte5.1 percentage (0..100%)CRT
204[RGB] Lock Channels1 = Locked, 0 = Not locked1 Bit1.3 enableCW
204[RGBW] Lock Channels Input1 = Lock, 0 = Unlock1 Bit1.3 enableCW
205[Dimmer] LED Power supply On/Off1 = On, 0 = Off1 Bit1.1 switchCRT
206[RGBW] RGBW Colour InputRGBW Colour 4x(0..100%)6 Bytes251.600 RGBW value 4x(0..100%)CW
207[RGBW] RGBW Colour FeedbackCurrent Colour RGBW 4x(0..100%)6 Bytes251.600 RGBW value 4x(0..100%)CRT
208[RGB] Relative control RGB Colour InputRelative Control (3 Bytes)3 Bytes254.600 RGB relative controlCW
209[RGBW] Relative control RGBW Colour InputRelative Control (5 Bytes)5 Bytes252.600 RGBW relative controlCW
210RGB_GODUMMY8RGB_GODUMMY84 BytesDPT.12CWT
211RGB_GODUMMY9RGB_GODUMMY94 BytesDPT.12CWT
212RGB_GODUMMY10RGB_GODUMMY104 BytesDPT.12CWT
213[Seq1] Start/Stop Sequence 11 = Start, 0 = Stop1 Bit1.1 switchCW
214[Seq1] Sequence 1 Feedback1 = On, 0 = Off1 Bit1.1 switchCRT
215[Seq2] Start/Stop Sequence 21 = Start, 0 = Stop1 Bit1.1 switchCW
216[Seq2] Sequence 2 Feedback1 = On, 0 = Off1 Bit1.1 switchCRT
217[Seq3] Start/Stop Sequence 31 = Start, 0 = Stop1 Bit1.1 switchCW
218[Seq3] Sequence 3 Feedback1 = On, 0 = Off1 Bit1.1 switchCRT
219[Seq4] Start/Stop Sequence 41 = Start, 0 = Stop1 Bit1.1 switchCW
220[Seq4] Sequence 4 Feedback1 = On, 0 = Off1 Bit1.1 switchCRT
221[Seq5] Start/Stop Sequence 51 = Start, 0 = Stop1 Bit1.1 switchCW
222[Seq5] Sequence 5 Feedback1 = On, 0 = Off1 Bit1.1 switchCRT
225[In1] Disable Temperature Functionality1 = Disable, 0 = Enable1 Bit1.3 enableCW
225[In1] Disable Input1 = Disable, 0 = Enable1 Bit1.3 enableCW
226[In1] Bit value on pressBit value1 Bit1.11 stateCRT
226[In1] 2 Bytes value on press2 Bytes value2 Bytes7.1 pulsesCRT
226[In1] Scene 1 Bit0 = Scene 1, 1 = Scene 21 Bit1.22 sceneCRT
226[In1] 4 Bytes value on press4 Bytes value4 Bytes12.1 counter pulses (unsigned)CRT
226[In1] Temperature valueTemperature2 Bytes9.1 temperature (°C)CRT
226[In1] Byte value on pressByte value1 Byte5.10 counter pulses (0..255)CRT
226[In1] Switch1 = On, 0 = Off1 Bit1.1 switchCRT
226[In1] Scene Control 8 BitsScene Control1 Byte18.1 scene controlCRT
226[In1] Stop / Step0 = Step Up, 1 = Step Down1 Bit1.7 stepCRT
226[In1] 2 Bytes signed value on press2 Bytes signed value2 Bytes8.1 pulses differenceCRT
226[In1] Counter direction0 = Up, 1 = Down1 Bit1.8 up/downCW
226[In1] 2 Bits value on press2 Bits value2 Bit2.1 switch controlCRT
226[In1] 2 Bytes floating value on press2 Bytes floating value2 Bytes9.1 temperature (°C)CRT
226[In1] RGB Colour OutputRGB colour3 Bytes232.600 RGB value 3x(0..255)CRT
226[In1] HVAC modeHVAC mode1 Byte20.102 HVAC modeCRT
226[In1] SceneScene1 Byte17.1 scene numberCRT
226[In1] Dimming ValueDimming value 0-100%1 Byte5.1 percentage (0..100%)CRT
226[In1] RGBW Colour OutputRGBW colour6 Bytes251.600 RGBW value 4x(0..100%)CRT
227[In1] Reset Counter0 = No action, 1 = Reset1 Bit1.15 resetCW
227[In1] Switch 21 = On, 0 = Off1 Bit1.1 switchCRT
227[In1] 4 Bytes value on Long press4 Bytes value4 Bytes12.1 counter pulses (unsigned)CRT
227[In1] 2 Bits value on Long press2 Bits value2 Bit2.1 switch controlCRT
227[In1] Long Switch1 = On, 0 = Off1 Bit1.1 switchCRT
227[In1] 2 Bytes floating value on Long press2 Bytes floating value2 Bytes9.1 temperature (°C)CRT
227[In1] Byte value on Long pressByte value1 Byte5.10 counter pulses (0..255)CRT
227[In1] Sensor not connected0 = Sensor Ok, 1 = Sensor not connected1 Bit1.11 stateCRT
227[In1] 2 Bytes signed value on Long press2 Bytes signed value2 Bytes8.1 pulses differenceCRT
227[In1] 2 Bytes value on Long press2 Bytes value2 Bytes7.1 pulsesCRT
227[In1] Bit value on Long pressBit value1 Bit1.11 stateCRT
227[In1] Dimming ControlDimming Control4 Bit3.7 dimming controlCRT
227[In1] Save Scene0 = No action, 1 = Save Scene1 Bit1.3 enableCW
227[In1] Move0 = Up, 1 = Down1 Bit1.8 up/downCRT
227[In1] HVAC mode [2]HVAC mode1 Byte20.102 HVAC modeCRT
227[In1] Scene [2]Scene1 Byte17.1 scene numberCRT
227[In1] Dimming Value [2]Dimming value 0-100%1 Byte5.1 percentage (0..100%)CRT
227[In1] Switch [2]1 = On, 0 = Off1 Bit1.1 switchCRT
228[In1] Over-Heating Output1 = Over-Heating, 0 = No Over-Heating1 Bit1.5 alarmCRT
228[In1] Switch 31 = On, 0 = Off1 Bit1.1 switchCRT
228[In1] Request Counter1 = Trigger1 Bit1.17 triggerCW
228[In1] Switch Feedback1 = On, 0 = Off1 Bit1.1 switchCW
229[In1] Counter 8 BitsCounter (0..255)1 Byte5.10 counter pulses (0..255)CRT
229[In1] Counter 16 BitsCounter (0..65535)2 Bytes7.1 pulsesCRT
229[In1] Over-Cooling Output1 = Over-Cooling, 0 = No Over-Cooling1 Bit1.5 alarmCRT
229[In1] Switch 41 = On, 0 = Off1 Bit1.1 switchCRT
229[In1] Long Switch Feedback1 = On, 0 = Off1 Bit1.1 switchCW
229[In1] Counter 32 BitsCounter (0..4.294.967.295)4 Bytes13.1 counter pulses (signed)CRT
229[In1] Switch [3]1 = On, 0 = Off1 Bit1.1 switchCRT
229[In1] Dimming value [3]Dimming value 0-100%1 Byte5.1 percentage (0..100%)CRT
229[In1] Scene [3]Scene1 Byte17.1 scene numberCRT
229[In1] HVAC mode [3]HVAC mode1 Byte20.102 HVAC modeCRT
230[In1] Switch 51 = On, 0 = Off1 Bit1.1 switchCRT
231[In1] Save Scene0 = Scene 1, 1 = Scene 21 Bit1.1 switchCRT
231[In1] Increase/Decrease0 = Increase, 1 = Decrease1 Bit1.8 up/downCW
232[In2] Disable Input1 = Disable, 0 = Enable1 Bit1.3 enableCW
232[In2] Disable Temperature Functionality1 = Disable, 0 = Enable1 Bit1.3 enableCW
233[In2] Switch1 = On, 0 = Off1 Bit1.1 switchCRT
233[In2] Stop / Step0 = Step Up, 1 = Step Down1 Bit1.7 stepCRT
233[In2] Scene Control 8 BitsScene Control1 Byte18.1 scene controlCRT
233[In2] Scene 1 Bit0 = Scene 1, 1 = Scene 21 Bit1.22 sceneCRT
233[In2] Bit value on pressBit value1 Bit1.11 stateCRT
233[In2] 2 Bits value on press2 Bits value2 Bit2.1 switch controlCRT
233[In2] Byte value on pressByte value1 Byte5.10 counter pulses (0..255)CRT
233[In2] 2 Bytes signed value on press2 Bytes signed value2 Bytes8.1 pulses differenceCRT
233[In2] 2 Bytes value on press2 Bytes value2 Bytes7.1 pulsesCRT
233[In2] 2 Bytes floating value on press2 Bytes floating value2 Bytes9.1 temperature (°C)CRT
233[In2] 4 Bytes value on press4 Bytes value4 Bytes12.1 counter pulses (unsigned)CRT
233[In2] Counter direction0 = Up, 1 = Down1 Bit1.8 up/downCW
233[In2] Temperature valueTemperature2 Bytes9.1 temperature (°C)CRT
233[In2] RGB Colour OutputRGB colour3 Bytes232.600 RGB value 3x(0..255)CRT
233[In2] Dimming ValueDimming value 0-100%1 Byte5.1 percentage (0..100%)CRT
233[In2] SceneScene1 Byte17.1 scene numberCRT
233[In2] HVAC modeHVAC mode1 Byte20.102 HVAC modeCRT
233[In2] RGBW Colour OutputRGBW colour6 Bytes251.600 RGBW value 4x(0..100%)CRT
234[In2] Long Switch1 = On, 0 = Off1 Bit1.1 switchCRT
234[In2] Dimming ControlDimming Control4 Bit3.7 dimming controlCRT
234[In2] Switch 21 = On, 0 = Off1 Bit1.1 switchCRT
234[In2] Move0 = Up, 1 = Down1 Bit1.8 up/downCRT
234[In2] Save Scene0 = No action, 1 = Save Scene1 Bit1.3 enableCW
234[In2] Bit value on Long pressBit value1 Bit1.11 stateCRT
234[In2] 2 Bits value on Long press2 Bits value2 Bit2.1 switch controlCRT
234[In2] Byte value on Long pressByte value1 Byte5.10 counter pulses (0..255)CRT
234[In2] 2 Bytes signed value on Long press2 Bytes signed value2 Bytes8.1 pulses differenceCRT
234[In2] 2 Bytes value on Long press2 Bytes value2 Bytes7.1 pulsesCRT
234[In2] 2 Bytes floating value on Long press2 Bytes floating value2 Bytes9.1 temperature (°C)CRT
234[In2] 4 Bytes value on Long press4 Bytes value4 Bytes12.1 counter pulses (unsigned)CRT
234[In2] Reset Counter0 = No action, 1 = Reset1 Bit1.15 resetCW
234[In2] Sensor not connected0 = Sensor Ok, 1 = Sensor not connected1 Bit1.11 stateCRT
234[In2] Switch [2]1 = On, 0 = Off1 Bit1.1 switchCRT
234[In2] Dimming Value [2]Dimming value 0-100%1 Byte5.1 percentage (0..100%)CRT
234[In2] Scene [2]Scene1 Byte17.1 scene numberCRT
234[In2] HVAC mode [2]HVAC mode1 Byte20.102 HVAC modeCRT
235[In2] Switch Feedback1 = On, 0 = Off1 Bit1.1 switchCW
235[In2] Switch 31 = On, 0 = Off1 Bit1.1 switchCRT
235[In2] Request Counter1 = Trigger1 Bit1.17 triggerCW
235[In2] Over-Heating Output1 = Over-Heating, 0 = No Over-Heating1 Bit1.5 alarmCRT
236[In2] Long Switch Feedback1 = On, 0 = Off1 Bit1.1 switchCW
236[In2] Switch 41 = On, 0 = Off1 Bit1.1 switchCRT
236[In2] Counter 8 BitsCounter (0..255)1 Byte5.10 counter pulses (0..255)CRT
236[In2] Counter 16 BitsCounter (0..65535)2 Bytes7.1 pulsesCRT
236[In2] Counter 32 BitsCounter (0..4.294.967.295)4 Bytes13.1 counter pulses (signed)CRT
236[In2] Over-Cooling Output1 = Over-Cooling, 0 = No Over-Cooling1 Bit1.5 alarmCRT
236[In2] Switch [3]1 = On, 0 = Off1 Bit1.1 switchCRT
236[In2] Dimming value [3]Dimming value 0-100%1 Byte5.1 percentage (0..100%)CRT
236[In2] Scene [3]Scene1 Byte17.1 scene numberCRT
236[In2] HVAC mode [3]HVAC mode1 Byte20.102 HVAC modeCRT
237[In2] Switch 51 = On, 0 = Off1 Bit1.1 switchCRT
238[In2] Increase/Decrease0 = Increase, 1 = Decrease1 Bit1.8 up/downCW
238[In2] Save Scene0 = Scene 1, 1 = Scene 21 Bit1.1 switchCRT
239[In3] Disable Input1 = Disable, 0 = Enable1 Bit1.3 enableCW
239[In3] Disable Temperature Functionality1 = Disable, 0 = Enable1 Bit1.3 enableCW
240[In3] Switch1 = On, 0 = Off1 Bit1.1 switchCRT
240[In3] Stop / Step0 = Step Up, 1 = Step Down1 Bit1.7 stepCRT
240[In3] Scene Control 8 BitsScene Control1 Byte18.1 scene controlCRT
240[In3] Scene 1 Bit0 = Scene 1, 1 = Scene 21 Bit1.22 sceneCRT
240[In3] Bit value on pressBit value1 Bit1.11 stateCRT
240[In3] 2 Bits value on press2 Bits value2 Bit2.1 switch controlCRT
240[In3] Byte value on pressByte value1 Byte5.10 counter pulses (0..255)CRT
240[In3] 2 Bytes signed value on press2 Bytes signed value2 Bytes8.1 pulses differenceCRT
240[In3] 2 Bytes value on press2 Bytes value2 Bytes7.1 pulsesCRT
240[In3] 2 Bytes floating value on press2 Bytes floating value2 Bytes9.1 temperature (°C)CRT
240[In3] 4 Bytes value on press4 Bytes value4 Bytes12.1 counter pulses (unsigned)CRT
240[In3] Counter direction0 = Up, 1 = Down1 Bit1.8 up/downCW
240[In3] Temperature valueTemperature2 Bytes9.1 temperature (°C)CRT
240[In3] RGB Colour OutputRGB colour3 Bytes232.600 RGB value 3x(0..255)CRT
240[In3] Dimming ValueDimming value 0-100%1 Byte5.1 percentage (0..100%)CRT
240[In3] SceneScene1 Byte17.1 scene numberCRT
240[In3] HVAC modeHVAC mode1 Byte20.102 HVAC modeCRT
240[In3] RGBW Colour OutputRGBW colour6 Bytes251.600 RGBW value 4x(0..100%)CRT
241[In3] Long Switch1 = On, 0 = Off1 Bit1.1 switchCRT
241[In3] Dimming ControlDimming Control4 Bit3.7 dimming controlCRT
241[In3] Switch 21 = On, 0 = Off1 Bit1.1 switchCRT
241[In3] Move0 = Up, 1 = Down1 Bit1.8 up/downCRT
241[In3] Save Scene0 = No action, 1 = Save Scene1 Bit1.3 enableCW
241[In3] Bit value on Long pressBit value1 Bit1.11 stateCRT
241[In3] 2 Bits value on Long press2 Bits value2 Bit2.1 switch controlCRT
241[In3] Byte value on Long pressByte value1 Byte5.10 counter pulses (0..255)CRT
241[In3] 2 Bytes signed value on Long press2 Bytes signed value2 Bytes8.1 pulses differenceCRT
241[In3] 2 Bytes value on Long press2 Bytes value2 Bytes7.1 pulsesCRT
241[In3] 2 Bytes floating value on Long press2 Bytes floating value2 Bytes9.1 temperature (°C)CRT
241[In3] 4 Bytes value on Long press4 Bytes value4 Bytes12.1 counter pulses (unsigned)CRT
241[In3] Reset Counter0 = No action, 1 = Reset1 Bit1.15 resetCW
241[In3] Sensor not connected0 = Sensor Ok, 1 = Sensor not connected1 Bit1.11 stateCRT
241[In3] Switch [2]1 = On, 0 = Off1 Bit1.1 switchCRT
241[In3] Dimming Value [2]Dimming value 0-100%1 Byte5.1 percentage (0..100%)CRT
241[In3] Scene [2]Scene1 Byte17.1 scene numberCRT
241[In3] HVAC mode [2]HVAC mode1 Byte20.102 HVAC modeCRT
242[In3] Switch Feedback1 = On, 0 = Off1 Bit1.1 switchCW
242[In3] Switch 31 = On, 0 = Off1 Bit1.1 switchCRT
242[In3] Request Counter1 = Trigger1 Bit1.17 triggerCW
242[In3] Over-Heating Output1 = Over-Heating, 0 = No Over-Heating1 Bit1.5 alarmCRT
243[In3] Long Switch Feedback1 = On, 0 = Off1 Bit1.1 switchCW
243[In3] Switch 41 = On, 0 = Off1 Bit1.1 switchCRT
243[In3] Counter 8 BitsCounter (0..255)1 Byte5.10 counter pulses (0..255)CRT
243[In3] Counter 16 BitsCounter (0..65535)2 Bytes7.1 pulsesCRT
243[In3] Counter 32 BitsCounter (0..4.294.967.295)4 Bytes13.1 counter pulses (signed)CRT
243[In3] Over-Cooling Output1 = Over-Cooling, 0 = No Over-Cooling1 Bit1.5 alarmCRT
243[In3] Switch [3]1 = On, 0 = Off1 Bit1.1 switchCRT
243[In3] Dimming value [3]Dimming value 0-100%1 Byte5.1 percentage (0..100%)CRT
243[In3] Scene [3]Scene1 Byte17.1 scene numberCRT
243[In3] HVAC mode [3]HVAC mode1 Byte20.102 HVAC modeCRT
244[In3] Switch 51 = On, 0 = Off1 Bit1.1 switchCRT
245[In3] Increase/Decrease0 = Increase, 1 = Decrease1 Bit1.8 up/downCW
245[In3] Save Scene0 = Scene 1, 1 = Scene 21 Bit1.1 switchCRT
246[In4] Disable Input1 = Disable, 0 = Enable1 Bit1.3 enableCW
246[In4] Disable Temperature Functionality1 = Disable, 0 = Enable1 Bit1.3 enableCW
247[In4] Switch1 = On, 0 = Off1 Bit1.1 switchCRT
247[In4] Stop / Step0 = Step Up, 1 = Step Down1 Bit1.7 stepCRT
247[In4] Scene Control 8 BitsScene Control1 Byte18.1 scene controlCRT
247[In4] Scene 1 Bit0 = Scene 1, 1 = Scene 21 Bit1.22 sceneCRT
247[In4] Bit value on pressBit value1 Bit1.11 stateCRT
247[In4] 2 Bits value on press2 Bits value2 Bit2.1 switch controlCRT
247[In4] Byte value on pressByte value1 Byte5.10 counter pulses (0..255)CRT
247[In4] 2 Bytes signed value on press2 Bytes signed value2 Bytes8.1 pulses differenceCRT
247[In4] 2 Bytes value on press2 Bytes value2 Bytes7.1 pulsesCRT
247[In4] 2 Bytes floating value on press2 Bytes floating value2 Bytes9.1 temperature (°C)CRT
247[In4] 4 Bytes value on press4 Bytes value4 Bytes12.1 counter pulses (unsigned)CRT
247[In4] Counter direction0 = Up, 1 = Down1 Bit1.8 up/downCW
247[In4] Temperature valueTemperature2 Bytes9.1 temperature (°C)CRT
247[In4] RGB Colour OutputRGB colour3 Bytes232.600 RGB value 3x(0..255)CRT
247[In4] Dimming ValueDimming value 0-100%1 Byte5.1 percentage (0..100%)CRT
247[In4] SceneScene1 Byte17.1 scene numberCRT
247[In4] HVAC modeHVAC mode1 Byte20.102 HVAC modeCRT
247[In4] RGBW Colour OutputRGBW colour6 Bytes251.600 RGBW value 4x(0..100%)CRT
248[In4] Long Switch1 = On, 0 = Off1 Bit1.1 switchCRT
248[In4] Dimming ControlDimming Control4 Bit3.7 dimming controlCRT
248[In4] Switch 21 = On, 0 = Off1 Bit1.1 switchCRT
248[In4] Move0 = Up, 1 = Down1 Bit1.8 up/downCRT
248[In4] Save Scene0 = No action, 1 = Save Scene1 Bit1.3 enableCW
248[In4] Bit value on Long pressBit value1 Bit1.11 stateCRT
248[In4] 2 Bits value on Long press2 Bits value2 Bit2.1 switch controlCRT
248[In4] Byte value on Long pressByte value1 Byte5.10 counter pulses (0..255)CRT
248[In4] 2 Bytes signed value on Long press2 Bytes signed value2 Bytes8.1 pulses differenceCRT
248[In4] 2 Bytes value on Long press2 Bytes value2 Bytes7.1 pulsesCRT
248[In4] 2 Bytes floating value on Long press2 Bytes floating value2 Bytes9.1 temperature (°C)CRT
248[In4] 4 Bytes value on Long press4 Bytes value4 Bytes12.1 counter pulses (unsigned)CRT
248[In4] Reset Counter0 = No action, 1 = Reset1 Bit1.15 resetCW
248[In4] Sensor not connected0 = Sensor Ok, 1 = Sensor not connected1 Bit1.11 stateCRT
248[In4] Switch [2]1 = On, 0 = Off1 Bit1.1 switchCRT
248[In4] Dimming Value [2]Dimming value 0-100%1 Byte5.1 percentage (0..100%)CRT
248[In4] Scene [2]Scene1 Byte17.1 scene numberCRT
248[In4] HVAC mode [2]HVAC mode1 Byte20.102 HVAC modeCRT
249[In4] Switch Feedback1 = On, 0 = Off1 Bit1.1 switchCW
249[In4] Switch 31 = On, 0 = Off1 Bit1.1 switchCRT
249[In4] Request Counter1 = Trigger1 Bit1.17 triggerCW
249[In4] Over-Heating Output1 = Over-Heating, 0 = No Over-Heating1 Bit1.5 alarmCRT
250[In4] Long Switch Feedback1 = On, 0 = Off1 Bit1.1 switchCW
250[In4] Switch 41 = On, 0 = Off1 Bit1.1 switchCRT
250[In4] Counter 8 BitsCounter (0..255)1 Byte5.10 counter pulses (0..255)CRT
250[In4] Counter 16 BitsCounter (0..65535)2 Bytes7.1 pulsesCRT
250[In4] Counter 32 BitsCounter (0..4.294.967.295)4 Bytes13.1 counter pulses (signed)CRT
250[In4] Over-Cooling Output1 = Over-Cooling, 0 = No Over-Cooling1 Bit1.5 alarmCRT
250[In4] Switch [3]1 = On, 0 = Off1 Bit1.1 switchCRT
250[In4] Dimming value [3]Dimming value 0-100%1 Byte5.1 percentage (0..100%)CRT
250[In4] Scene [3]Scene1 Byte17.1 scene numberCRT
250[In4] HVAC mode [3]HVAC mode1 Byte20.102 HVAC modeCRT
251[In4] Switch 51 = On, 0 = Off1 Bit1.1 switchCRT
252[In4] Increase/Decrease0 = Increase, 1 = Decrease1 Bit1.8 up/downCW
252[In4] Save Scene0 = Scene 1, 1 = Scene 21 Bit1.1 switchCRT
253[In5] Disable Input1 = Disable, 0 = Enable1 Bit1.3 enableCW
253[In5] Disable Temperature Functionality1 = Disable, 0 = Enable1 Bit1.3 enableCW
254[In5] Switch1 = On, 0 = Off1 Bit1.1 switchCRT
254[In5] Stop / Step0 = Step Up, 1 = Step Down1 Bit1.7 stepCRT
254[In5] Scene Control 8 BitsScene Control1 Byte18.1 scene controlCRT
254[In5] Scene 1 Bit0 = Scene 1, 1 = Scene 21 Bit1.22 sceneCRT
254[In5] Bit value on pressBit value1 Bit1.11 stateCRT
254[In5] 2 Bits value on press2 Bits value2 Bit2.1 switch controlCRT
254[In5] Byte value on pressByte value1 Byte5.10 counter pulses (0..255)CRT
254[In5] 2 Bytes signed value on press2 Bytes signed value2 Bytes8.1 pulses differenceCRT
254[In5] 2 Bytes value on press2 Bytes value2 Bytes7.1 pulsesCRT
254[In5] 2 Bytes floating value on press2 Bytes floating value2 Bytes9.1 temperature (°C)CRT
254[In5] 4 Bytes value on press4 Bytes value4 Bytes12.1 counter pulses (unsigned)CRT
254[In5] Counter direction0 = Up, 1 = Down1 Bit1.8 up/downCW
254[In5] Temperature valueTemperature2 Bytes9.1 temperature (°C)CRT
254[In5] RGB Colour OutputRGB colour3 Bytes232.600 RGB value 3x(0..255)CRT
254[In5] RGBW Colour OutputRGBW colour6 Bytes251.600 RGBW value 4x(0..100%)CRT
255[In5] Long Switch1 = On, 0 = Off1 Bit1.1 switchCRT
255[In5] Dimming ControlDimming Control4 Bit3.7 dimming controlCRT
255[In5] Switch 21 = On, 0 = Off1 Bit1.1 switchCRT
255[In5] Move0 = Up, 1 = Down1 Bit1.8 up/downCRT
255[In5] Save Scene0 = No action, 1 = Save Scene1 Bit1.3 enableCW
255[In5] Bit value on Long pressBit value1 Bit1.11 stateCRT
255[In5] 2 Bits value on Long press2 Bits value2 Bit2.1 switch controlCRT
255[In5] Byte value on Long pressByte value1 Byte5.10 counter pulses (0..255)CRT
255[In5] 2 Bytes signed value on Long press2 Bytes signed value2 Bytes8.1 pulses differenceCRT
255[In5] 2 Bytes value on Long press2 Bytes value2 Bytes7.1 pulsesCRT
255[In5] 2 Bytes floating value on Long press2 Bytes floating value2 Bytes9.1 temperature (°C)CRT
255[In5] 4 Bytes value on Long press4 Bytes value4 Bytes12.1 counter pulses (unsigned)CRT
255[In5] Reset Counter0 = No action, 1 = Reset1 Bit1.15 resetCW
255[In5] Sensor not connected0 = Sensor Ok, 1 = Sensor not connected1 Bit1.11 stateCRT
256[In5] Switch Feedback1 = On, 0 = Off1 Bit1.1 switchCW
256[In5] Switch 31 = On, 0 = Off1 Bit1.1 switchCRT
256[In5] Request Counter1 = Trigger1 Bit1.17 triggerCW
256[In5] Over-Heating Output1 = Over-Heating, 0 = No Over-Heating1 Bit1.5 alarmCRT
257[In5] Long Switch Feedback1 = On, 0 = Off1 Bit1.1 switchCW
257[In5] Switch 41 = On, 0 = Off1 Bit1.1 switchCRT
257[In5] Counter 8 BitsCounter (0..255)1 Byte5.10 counter pulses (0..255)CRT
257[In5] Counter 16 BitsCounter (0..65535)2 Bytes7.1 pulsesCRT
257[In5] Counter 32 BitsCounter (0..4.294.967.295)4 Bytes13.1 counter pulses (signed)CRT
257[In5] Over-Cooling Output1 = Over-Cooling, 0 = No Over-Cooling1 Bit1.5 alarmCRT
258[In5] Switch 51 = On, 0 = Off1 Bit1.1 switchCRT
259[In5] Increase/Decrease0 = Increase, 1 = Decrease1 Bit1.8 up/downCW
259[In5] Save Scene0 = Scene 1, 1 = Scene 21 Bit1.1 switchCRT
260[In6] Disable Input1 = Disable, 0 = Enable1 Bit1.3 enableCW
260[In6] Disable Temperature Functionality1 = Disable, 0 = Enable1 Bit1.3 enableCW
261[In6] Switch1 = On, 0 = Off1 Bit1.1 switchCRT
261[In6] Stop / Step0 = Step Up, 1 = Step Down1 Bit1.7 stepCRT
261[In6] Scene Control 8 BitsScene Control1 Byte18.1 scene controlCRT
261[In6] Scene 1 Bit0 = Scene 1, 1 = Scene 21 Bit1.22 sceneCRT
261[In6] Bit value on pressBit value1 Bit1.11 stateCRT
261[In6] 2 Bits value on press2 Bits value2 Bit2.1 switch controlCRT
261[In6] Byte value on pressByte value1 Byte5.10 counter pulses (0..255)CRT
261[In6] 2 Bytes signed value on press2 Bytes signed value2 Bytes8.1 pulses differenceCRT
261[In6] 2 Bytes value on press2 Bytes value2 Bytes7.1 pulsesCRT
261[In6] 2 Bytes floating value on press2 Bytes floating value2 Bytes9.1 temperature (°C)CRT
261[In6] 4 Bytes value on press4 Bytes value4 Bytes12.1 counter pulses (unsigned)CRT
261[In6] Counter direction0 = Up, 1 = Down1 Bit1.8 up/downCW
261[In6] Temperature valueTemperature2 Bytes9.1 temperature (°C)CRT
261[In6] RGB Colour OutputRGB colour3 Bytes232.600 RGB value 3x(0..255)CRT
261[In6] RGBW Colour OutputRGBW colour6 Bytes251.600 RGBW value 4x(0..100%)CRT
262[In6] Long Switch1 = On, 0 = Off1 Bit1.1 switchCRT
262[In6] Dimming ControlDimming Control4 Bit3.7 dimming controlCRT
262[In6] Switch 21 = On, 0 = Off1 Bit1.1 switchCRT
262[In6] Move0 = Up, 1 = Down1 Bit1.8 up/downCRT
262[In6] Save Scene0 = No action, 1 = Save Scene1 Bit1.3 enableCW
262[In6] Bit value on Long pressBit value1 Bit1.11 stateCRT
262[In6] 2 Bits value on Long press2 Bits value2 Bit2.1 switch controlCRT
262[In6] Byte value on Long pressByte value1 Byte5.10 counter pulses (0..255)CRT
262[In6] 2 Bytes signed value on Long press2 Bytes signed value2 Bytes8.1 pulses differenceCRT
262[In6] 2 Bytes value on Long press2 Bytes value2 Bytes7.1 pulsesCRT
262[In6] 2 Bytes floating value on Long press2 Bytes floating value2 Bytes9.1 temperature (°C)CRT
262[In6] 4 Bytes value on Long press4 Bytes value4 Bytes12.1 counter pulses (unsigned)CRT
262[In6] Reset Counter0 = No action, 1 = Reset1 Bit1.15 resetCW
262[In6] Sensor not connected0 = Sensor Ok, 1 = Sensor not connected1 Bit1.11 stateCRT
263[In6] Switch Feedback1 = On, 0 = Off1 Bit1.1 switchCW
263[In6] Switch 31 = On, 0 = Off1 Bit1.1 switchCRT
263[In6] Request Counter1 = Trigger1 Bit1.17 triggerCW
263[In6] Over-Heating Output1 = Over-Heating, 0 = No Over-Heating1 Bit1.5 alarmCRT
264[In6] Long Switch Feedback1 = On, 0 = Off1 Bit1.1 switchCW
264[In6] Switch 41 = On, 0 = Off1 Bit1.1 switchCRT
264[In6] Counter 8 BitsCounter (0..255)1 Byte5.10 counter pulses (0..255)CRT
264[In6] Counter 16 BitsCounter (0..65535)2 Bytes7.1 pulsesCRT
264[In6] Counter 32 BitsCounter (0..4.294.967.295)4 Bytes13.1 counter pulses (signed)CRT
264[In6] Over-Cooling Output1 = Over-Cooling, 0 = No Over-Cooling1 Bit1.5 alarmCRT
265[In6] Switch 51 = On, 0 = Off1 Bit1.1 switchCRT
266[In6] Increase/Decrease0 = Increase, 1 = Decrease1 Bit1.8 up/downCW
266[In6] Save Scene0 = Scene 1, 1 = Scene 21 Bit1.1 switchCRT
267[In7] Disable Input1 = Disable, 0 = Enable1 Bit1.3 enableCW
267[In7] Disable Temperature Functionality1 = Disable, 0 = Enable1 Bit1.3 enableCW
268[In7] Switch1 = On, 0 = Off1 Bit1.1 switchCRT
268[In7] Stop / Step0 = Step Up, 1 = Step Down1 Bit1.7 stepCRT
268[In7] Scene Control 8 BitsScene Control1 Byte18.1 scene controlCRT
268[In7] Scene 1 Bit0 = Scene 1, 1 = Scene 21 Bit1.22 sceneCRT
268[In7] Bit value on pressBit value1 Bit1.11 stateCRT
268[In7] 2 Bits value on press2 Bits value2 Bit2.1 switch controlCRT
268[In7] Byte value on pressByte value1 Byte5.10 counter pulses (0..255)CRT
268[In7] 2 Bytes signed value on press2 Bytes signed value2 Bytes8.1 pulses differenceCRT
268[In7] 2 Bytes value on press2 Bytes value2 Bytes7.1 pulsesCRT
268[In7] 2 Bytes floating value on press2 Bytes floating value2 Bytes9.1 temperature (°C)CRT
268[In7] 4 Bytes value on press4 Bytes value4 Bytes12.1 counter pulses (unsigned)CRT
268[In7] Counter direction0 = Up, 1 = Down1 Bit1.8 up/downCW
268[In7] Temperature valueTemperature2 Bytes9.1 temperature (°C)CRT
268[In7] RGB Colour OutputRGB colour3 Bytes232.600 RGB value 3x(0..255)CRT
268[In7] RGBW Colour OutputRGBW colour6 Bytes251.600 RGBW value 4x(0..100%)CRT
269[In7] Long Switch1 = On, 0 = Off1 Bit1.1 switchCRT
269[In7] Dimming ControlDimming Control4 Bit3.7 dimming controlCRT
269[In7] Switch 21 = On, 0 = Off1 Bit1.1 switchCRT
269[In7] Move0 = Up, 1 = Down1 Bit1.8 up/downCRT
269[In7] Save Scene0 = No action, 1 = Save Scene1 Bit1.3 enableCW
269[In7] Bit value on Long pressBit value1 Bit1.11 stateCRT
269[In7] 2 Bits value on Long press2 Bits value2 Bit2.1 switch controlCRT
269[In7] Byte value on Long pressByte value1 Byte5.10 counter pulses (0..255)CRT
269[In7] 2 Bytes signed value on Long press2 Bytes signed value2 Bytes8.1 pulses differenceCRT
269[In7] 2 Bytes value on Long press2 Bytes value2 Bytes7.1 pulsesCRT
269[In7] 2 Bytes floating value on Long press2 Bytes floating value2 Bytes9.1 temperature (°C)CRT
269[In7] 4 Bytes value on Long press4 Bytes value4 Bytes12.1 counter pulses (unsigned)CRT
269[In7] Reset Counter0 = No action, 1 = Reset1 Bit1.15 resetCW
269[In7] Sensor not connected0 = Sensor Ok, 1 = Sensor not connected1 Bit1.11 stateCRT
270[In7] Switch Feedback1 = On, 0 = Off1 Bit1.1 switchCW
270[In7] Switch 31 = On, 0 = Off1 Bit1.1 switchCRT
270[In7] Request Counter1 = Trigger1 Bit1.17 triggerCW
270[In7] Over-Heating Output1 = Over-Heating, 0 = No Over-Heating1 Bit1.5 alarmCRT
271[In7] Long Switch Feedback1 = On, 0 = Off1 Bit1.1 switchCW
271[In7] Switch 41 = On, 0 = Off1 Bit1.1 switchCRT
271[In7] Counter 8 BitsCounter (0..255)1 Byte5.10 counter pulses (0..255)CRT
271[In7] Counter 16 BitsCounter (0..65535)2 Bytes7.1 pulsesCRT
271[In7] Counter 32 BitsCounter (0..4.294.967.295)4 Bytes13.1 counter pulses (signed)CRT
271[In7] Over-Cooling Output1 = Over-Cooling, 0 = No Over-Cooling1 Bit1.5 alarmCRT
272[In7] Switch 51 = On, 0 = Off1 Bit1.1 switchCRT
273[In7] Increase/Decrease0 = Increase, 1 = Decrease1 Bit1.8 up/downCW
273[In7] Save Scene0 = Scene 1, 1 = Scene 21 Bit1.1 switchCRT
274[In8] Disable Input1 = Disable, 0 = Enable1 Bit1.3 enableCW
274[In8] Disable Temperature Functionality1 = Disable, 0 = Enable1 Bit1.3 enableCW
275[In8] Switch1 = On, 0 = Off1 Bit1.1 switchCRT
275[In8] Stop / Step0 = Step Up, 1 = Step Down1 Bit1.7 stepCRT
275[In8] Scene Control 8 BitsScene Control1 Byte18.1 scene controlCRT
275[In8] Scene 1 Bit0 = Scene 1, 1 = Scene 21 Bit1.22 sceneCRT
275[In8] Bit value on pressBit value1 Bit1.11 stateCRT
275[In8] 2 Bits value on press2 Bits value2 Bit2.1 switch controlCRT
275[In8] Byte value on pressByte value1 Byte5.10 counter pulses (0..255)CRT
275[In8] 2 Bytes signed value on press2 Bytes signed value2 Bytes8.1 pulses differenceCRT
275[In8] 2 Bytes value on press2 Bytes value2 Bytes7.1 pulsesCRT
275[In8] 2 Bytes floating value on press2 Bytes floating value2 Bytes9.1 temperature (°C)CRT
275[In8] 4 Bytes value on press4 Bytes value4 Bytes12.1 counter pulses (unsigned)CRT
275[In8] Counter direction0 = Up, 1 = Down1 Bit1.8 up/downCW
275[In8] Temperature valueTemperature2 Bytes9.1 temperature (°C)CRT
275[In8] RGB Colour OutputRGB colour3 Bytes232.600 RGB value 3x(0..255)CRT
275[In8] RGBW Colour OutputRGBW colour6 Bytes251.600 RGBW value 4x(0..100%)CRT
276[In8] Long Switch1 = On, 0 = Off1 Bit1.1 switchCRT
276[In8] Dimming ControlDimming Control4 Bit3.7 dimming controlCRT
276[In8] Switch 21 = On, 0 = Off1 Bit1.1 switchCRT
276[In8] Move0 = Up, 1 = Down1 Bit1.8 up/downCRT
276[In8] Save Scene0 = No action, 1 = Save Scene1 Bit1.3 enableCW
276[In8] Bit value on Long pressBit value1 Bit1.11 stateCRT
276[In8] 2 Bits value on Long press2 Bits value2 Bit2.1 switch controlCRT
276[In8] Byte value on Long pressByte value1 Byte5.10 counter pulses (0..255)CRT
276[In8] 2 Bytes signed value on Long press2 Bytes signed value2 Bytes8.1 pulses differenceCRT
276[In8] 2 Bytes value on Long press2 Bytes value2 Bytes7.1 pulsesCRT
276[In8] 2 Bytes floating value on Long press2 Bytes floating value2 Bytes9.1 temperature (°C)CRT
276[In8] 4 Bytes value on Long press4 Bytes value4 Bytes12.1 counter pulses (unsigned)CRT
276[In8] Reset Counter0 = No action, 1 = Reset1 Bit1.15 resetCW
276[In8] Sensor not connected0 = Sensor Ok, 1 = Sensor not connected1 Bit1.11 stateCRT
277[In8] Switch Feedback1 = On, 0 = Off1 Bit1.1 switchCW
277[In8] Switch 31 = On, 0 = Off1 Bit1.1 switchCRT
277[In8] Request Counter1 = Trigger1 Bit1.17 triggerCW
277[In8] Over-Heating Output1 = Over-Heating, 0 = No Over-Heating1 Bit1.5 alarmCRT
278[In8] Long Switch Feedback1 = On, 0 = Off1 Bit1.1 switchCW
278[In8] Switch 41 = On, 0 = Off1 Bit1.1 switchCRT
278[In8] Counter 8 BitsCounter (0..255)1 Byte5.10 counter pulses (0..255)CRT
278[In8] Counter 16 BitsCounter (0..65535)2 Bytes7.1 pulsesCRT
278[In8] Counter 32 BitsCounter (0..4.294.967.295)4 Bytes13.1 counter pulses (signed)CRT
278[In8] Over-Cooling Output1 = Over-Cooling, 0 = No Over-Cooling1 Bit1.5 alarmCRT
279[In8] Switch 51 = On, 0 = Off1 Bit1.1 switchCRT
280[In8] Increase/Decrease0 = Increase, 1 = Decrease1 Bit1.8 up/downCW
280[In8] Save Scene0 = Scene 1, 1 = Scene 21 Bit1.1 switchCRT
281[In9] Disable Input1 = Disable, 0 = Enable1 Bit1.3 enableCW
281[In9] Disable Temperature Functionality1 = Disable, 0 = Enable1 Bit1.3 enableCW
282[In9] Switch1 = On, 0 = Off1 Bit1.1 switchCRT
282[In9] Stop / Step0 = Step Up, 1 = Step Down1 Bit1.7 stepCRT
282[In9] Scene Control 8 BitsScene Control1 Byte18.1 scene controlCRT
282[In9] Scene 1 Bit0 = Scene 1, 1 = Scene 21 Bit1.22 sceneCRT
282[In9] Bit value on pressBit value1 Bit1.11 stateCRT
282[In9] 2 Bits value on press2 Bits value2 Bit2.1 switch controlCRT
282[In9] Byte value on pressByte value1 Byte5.10 counter pulses (0..255)CRT
282[In9] 2 Bytes signed value on press2 Bytes signed value2 Bytes8.1 pulses differenceCRT
282[In9] 2 Bytes value on press2 Bytes value2 Bytes7.1 pulsesCRT
282[In9] 2 Bytes floating value on press2 Bytes floating value2 Bytes9.1 temperature (°C)CRT
282[In9] 4 Bytes value on press4 Bytes value4 Bytes12.1 counter pulses (unsigned)CRT
282[In9] Counter direction0 = Up, 1 = Down1 Bit1.8 up/downCW
282[In9] Temperature valueTemperature2 Bytes9.1 temperature (°C)CRT
282[In9] RGB Colour OutputRGB colour3 Bytes232.600 RGB value 3x(0..255)CRT
282[In9] RGBW Colour OutputRGBW colour6 Bytes251.600 RGBW value 4x(0..100%)CRT
283[In9] Long Switch1 = On, 0 = Off1 Bit1.1 switchCRT
283[In9] Dimming ControlDimming Control4 Bit3.7 dimming controlCRT
283[In9] Switch 21 = On, 0 = Off1 Bit1.1 switchCRT
283[In9] Move0 = Up, 1 = Down1 Bit1.8 up/downCRT
283[In9] Save Scene0 = No action, 1 = Save Scene1 Bit1.3 enableCW
283[In9] Bit value on Long pressBit value1 Bit1.11 stateCRT
283[In9] 2 Bits value on Long press2 Bits value2 Bit2.1 switch controlCRT
283[In9] Byte value on Long pressByte value1 Byte5.10 counter pulses (0..255)CRT
283[In9] 2 Bytes signed value on Long press2 Bytes signed value2 Bytes8.1 pulses differenceCRT
283[In9] 2 Bytes value on Long press2 Bytes value2 Bytes7.1 pulsesCRT
283[In9] 2 Bytes floating value on Long press2 Bytes floating value2 Bytes9.1 temperature (°C)CRT
283[In9] 4 Bytes value on Long press4 Bytes value4 Bytes12.1 counter pulses (unsigned)CRT
283[In9] Reset Counter0 = No action, 1 = Reset1 Bit1.15 resetCW
283[In9] Sensor not connected0 = Sensor Ok, 1 = Sensor not connected1 Bit1.11 stateCRT
284[In9] Switch Feedback1 = On, 0 = Off1 Bit1.1 switchCW
284[In9] Switch 31 = On, 0 = Off1 Bit1.1 switchCRT
284[In9] Request Counter1 = Trigger1 Bit1.17 triggerCW
284[In9] Over-Heating Output1 = Over-Heating, 0 = No Over-Heating1 Bit1.5 alarmCRT
285[In9] Long Switch Feedback1 = On, 0 = Off1 Bit1.1 switchCW
285[In9] Switch 41 = On, 0 = Off1 Bit1.1 switchCRT
285[In9] Counter 8 BitsCounter (0..255)1 Byte5.10 counter pulses (0..255)CRT
285[In9] Counter 16 BitsCounter (0..65535)2 Bytes7.1 pulsesCRT
285[In9] Counter 32 BitsCounter (0..4.294.967.295)4 Bytes13.1 counter pulses (signed)CRT
285[In9] Over-Cooling Output1 = Over-Cooling, 0 = No Over-Cooling1 Bit1.5 alarmCRT
286[In9] Switch 51 = On, 0 = Off1 Bit1.1 switchCRT
287[In9] Increase/Decrease0 = Increase, 1 = Decrease1 Bit1.8 up/downCW
287[In9] Save Scene0 = Scene 1, 1 = Scene 21 Bit1.1 switchCRT
288[In10] Disable Input1 = Disable, 0 = Enable1 Bit1.3 enableCW
288[In10] Disable Temperature Functionality1 = Disable, 0 = Enable1 Bit1.3 enableCW
289[In10] Switch1 = On, 0 = Off1 Bit1.1 switchCRT
289[In10] Stop / Step0 = Step Up, 1 = Step Down1 Bit1.7 stepCRT
289[In10] Scene Control 8 BitsScene Control1 Byte18.1 scene controlCRT
289[In10] Scene 1 Bit0 = Scene 1, 1 = Scene 21 Bit1.22 sceneCRT
289[In10] Bit value on pressBit value1 Bit1.11 stateCRT
289[In10] 2 Bits value on press2 Bits value2 Bit2.1 switch controlCRT
289[In10] Byte value on pressByte value1 Byte5.10 counter pulses (0..255)CRT
289[In10] 2 Bytes signed value on press2 Bytes signed value2 Bytes8.1 pulses differenceCRT
289[In10] 2 Bytes value on press2 Bytes value2 Bytes7.1 pulsesCRT
289[In10] 2 Bytes floating value on press2 Bytes floating value2 Bytes9.1 temperature (°C)CRT
289[In10] 4 Bytes value on press4 Bytes value4 Bytes12.1 counter pulses (unsigned)CRT
289[In10] Counter direction0 = Up, 1 = Down1 Bit1.8 up/downCW
289[In10] Temperature valueTemperature2 Bytes9.1 temperature (°C)CRT
289[In10] RGB Colour OutputRGB colour3 Bytes232.600 RGB value 3x(0..255)CRT
289[In10] RGBW Colour OutputRGBW colour6 Bytes251.600 RGBW value 4x(0..100%)CRT
290[In10] Long Switch1 = On, 0 = Off1 Bit1.1 switchCRT
290[In10] Dimming ControlDimming Control4 Bit3.7 dimming controlCRT
290[In10] Switch 21 = On, 0 = Off1 Bit1.1 switchCRT
290[In10] Move0 = Up, 1 = Down1 Bit1.8 up/downCRT
290[In10] Save Scene0 = No action, 1 = Save Scene1 Bit1.3 enableCW
290[In10] Bit value on Long pressBit value1 Bit1.11 stateCRT
290[In10] 2 Bits value on Long press2 Bits value2 Bit2.1 switch controlCRT
290[In10] Byte value on Long pressByte value1 Byte5.10 counter pulses (0..255)CRT
290[In10] 2 Bytes signed value on Long press2 Bytes signed value2 Bytes8.1 pulses differenceCRT
290[In10] 2 Bytes value on Long press2 Bytes value2 Bytes7.1 pulsesCRT
290[In10] 2 Bytes floating value on Long press2 Bytes floating value2 Bytes9.1 temperature (°C)CRT
290[In10] 4 Bytes value on Long press4 Bytes value4 Bytes12.1 counter pulses (unsigned)CRT
290[In10] Reset Counter0 = No action, 1 = Reset1 Bit1.15 resetCW
290[In10] Sensor not connected0 = Sensor Ok, 1 = Sensor not connected1 Bit1.11 stateCRT
291[In10] Switch Feedback1 = On, 0 = Off1 Bit1.1 switchCW
291[In10] Switch 31 = On, 0 = Off1 Bit1.1 switchCRT
291[In10] Request Counter1 = Trigger1 Bit1.17 triggerCW
291[In10] Over-Heating Output1 = Over-Heating, 0 = No Over-Heating1 Bit1.5 alarmCRT
292[In10] Long Switch Feedback1 = On, 0 = Off1 Bit1.1 switchCW
292[In10] Switch 41 = On, 0 = Off1 Bit1.1 switchCRT
292[In10] Counter 8 BitsCounter (0..255)1 Byte5.10 counter pulses (0..255)CRT
292[In10] Counter 16 BitsCounter (0..65535)2 Bytes7.1 pulsesCRT
292[In10] Counter 32 BitsCounter (0..4.294.967.295)4 Bytes13.1 counter pulses (signed)CRT
292[In10] Over-Cooling Output1 = Over-Cooling, 0 = No Over-Cooling1 Bit1.5 alarmCRT
293[In10] Switch 51 = On, 0 = Off1 Bit1.1 switchCRT
294[In10] Increase/Decrease0 = Increase, 1 = Decrease1 Bit1.8 up/downCW
294[In10] Save Scene0 = Scene 1, 1 = Scene 21 Bit1.1 switchCRT
295[In11] Disable Input1 = Disable, 0 = Enable1 Bit1.3 enableCW
295[In11] Disable Temperature Functionality1 = Disable, 0 = Enable1 Bit1.3 enableCW
296[In11] Switch1 = On, 0 = Off1 Bit1.1 switchCRT
296[In11] Stop / Step0 = Step Up, 1 = Step Down1 Bit1.7 stepCRT
296[In11] Scene Control 8 BitsScene Control1 Byte18.1 scene controlCRT
296[In11] Scene 1 Bit0 = Scene 1, 1 = Scene 21 Bit1.22 sceneCRT
296[In11] Bit value on pressBit value1 Bit1.11 stateCRT
296[In11] 2 Bits value on press2 Bits value2 Bit2.1 switch controlCRT
296[In11] Byte value on pressByte value1 Byte5.10 counter pulses (0..255)CRT
296[In11] 2 Bytes signed value on press2 Bytes signed value2 Bytes8.1 pulses differenceCRT
296[In11] 2 Bytes value on press2 Bytes value2 Bytes7.1 pulsesCRT
296[In11] 2 Bytes floating value on press2 Bytes floating value2 Bytes9.1 temperature (°C)CRT
296[In11] 4 Bytes value on press4 Bytes value4 Bytes12.1 counter pulses (unsigned)CRT
296[In11] Counter direction0 = Up, 1 = Down1 Bit1.8 up/downCW
296[In11] Temperature valueTemperature2 Bytes9.1 temperature (°C)CRT
296[In11] RGB Colour OutputRGB colour3 Bytes232.600 RGB value 3x(0..255)CRT
296[In11] RGBW Colour OutputRGBW colour6 Bytes251.600 RGBW value 4x(0..100%)CRT
297[In11] Long Switch1 = On, 0 = Off1 Bit1.1 switchCRT
297[In11] Dimming ControlDimming Control4 Bit3.7 dimming controlCRT
297[In11] Switch 21 = On, 0 = Off1 Bit1.1 switchCRT
297[In11] Move0 = Up, 1 = Down1 Bit1.8 up/downCRT
297[In11] Save Scene0 = No action, 1 = Save Scene1 Bit1.3 enableCW
297[In11] Bit value on Long pressBit value1 Bit1.11 stateCRT
297[In11] 2 Bits value on Long press2 Bits value2 Bit2.1 switch controlCRT
297[In11] Byte value on Long pressByte value1 Byte5.10 counter pulses (0..255)CRT
297[In11] 2 Bytes signed value on Long press2 Bytes signed value2 Bytes8.1 pulses differenceCRT
297[In11] 2 Bytes value on Long press2 Bytes value2 Bytes7.1 pulsesCRT
297[In11] 2 Bytes floating value on Long press2 Bytes floating value2 Bytes9.1 temperature (°C)CRT
297[In11] 4 Bytes value on Long press4 Bytes value4 Bytes12.1 counter pulses (unsigned)CRT
297[In11] Reset Counter0 = No action, 1 = Reset1 Bit1.15 resetCW
297[In11] Sensor not connected0 = Sensor Ok, 1 = Sensor not connected1 Bit1.11 stateCRT
298[In11] Switch Feedback1 = On, 0 = Off1 Bit1.1 switchCW
298[In11] Switch 31 = On, 0 = Off1 Bit1.1 switchCRT
298[In11] Request Counter1 = Trigger1 Bit1.17 triggerCW
298[In11] Over-Heating Output1 = Over-Heating, 0 = No Over-Heating1 Bit1.5 alarmCRT
299[In11] Long Switch Feedback1 = On, 0 = Off1 Bit1.1 switchCW
299[In11] Switch 41 = On, 0 = Off1 Bit1.1 switchCRT
299[In11] Counter 8 BitsCounter (0..255)1 Byte5.10 counter pulses (0..255)CRT
299[In11] Counter 16 BitsCounter (0..65535)2 Bytes7.1 pulsesCRT
299[In11] Counter 32 BitsCounter (0..4.294.967.295)4 Bytes13.1 counter pulses (signed)CRT
299[In11] Over-Cooling Output1 = Over-Cooling, 0 = No Over-Cooling1 Bit1.5 alarmCRT
300[In11] Switch 51 = On, 0 = Off1 Bit1.1 switchCRT
301[In11] Increase/Decrease0 = Increase, 1 = Decrease1 Bit1.8 up/downCW
301[In11] Save Scene0 = Scene 1, 1 = Scene 21 Bit1.1 switchCRT
302[In12] Disable Input1 = Disable, 0 = Enable1 Bit1.3 enableCW
302[In12] Disable Temperature Functionality1 = Disable, 0 = Enable1 Bit1.3 enableCW
303[In12] Switch1 = On, 0 = Off1 Bit1.1 switchCRT
303[In12] Stop / Step0 = Step Up, 1 = Step Down1 Bit1.7 stepCRT
303[In12] Scene Control 8 BitsScene Control1 Byte18.1 scene controlCRT
303[In12] Scene 1 Bit0 = Scene 1, 1 = Scene 21 Bit1.22 sceneCRT
303[In12] Bit value on pressBit value1 Bit1.11 stateCRT
303[In12] 2 Bits value on press2 Bits value2 Bit2.1 switch controlCRT
303[In12] Byte value on pressByte value1 Byte5.10 counter pulses (0..255)CRT
303[In12] 2 Bytes signed value on press2 Bytes signed value2 Bytes8.1 pulses differenceCRT
303[In12] 2 Bytes value on press2 Bytes value2 Bytes7.1 pulsesCRT
303[In12] 2 Bytes floating value on press2 Bytes floating value2 Bytes9.1 temperature (°C)CRT
303[In12] 4 Bytes value on press4 Bytes value4 Bytes12.1 counter pulses (unsigned)CRT
303[In12] Counter direction0 = Up, 1 = Down1 Bit1.8 up/downCW
303[In12] Temperature valueTemperature2 Bytes9.1 temperature (°C)CRT
303[In12] RGB Colour OutputRGB colour3 Bytes232.600 RGB value 3x(0..255)CRT
303[In12] RGBW Colour OutputRGBW colour6 Bytes251.600 RGBW value 4x(0..100%)CRT
304[In12] Long Switch1 = On, 0 = Off1 Bit1.1 switchCRT
304[In12] Dimming ControlDimming Control4 Bit3.7 dimming controlCRT
304[In12] Switch 21 = On, 0 = Off1 Bit1.1 switchCRT
304[In12] Move0 = Up, 1 = Down1 Bit1.8 up/downCRT
304[In12] Save Scene0 = No action, 1 = Save Scene1 Bit1.3 enableCW
304[In12] Bit value on Long pressBit value1 Bit1.11 stateCRT
304[In12] 2 Bits value on Long press2 Bits value2 Bit2.1 switch controlCRT
304[In12] Byte value on Long pressByte value1 Byte5.10 counter pulses (0..255)CRT
304[In12] 2 Bytes signed value on Long press2 Bytes signed value2 Bytes8.1 pulses differenceCRT
304[In12] 2 Bytes value on Long press2 Bytes value2 Bytes7.1 pulsesCRT
304[In12] 2 Bytes floating value on Long press2 Bytes floating value2 Bytes9.1 temperature (°C)CRT
304[In12] 4 Bytes value on Long press4 Bytes value4 Bytes12.1 counter pulses (unsigned)CRT
304[In12] Reset Counter0 = No action, 1 = Reset1 Bit1.15 resetCW
304[In12] Sensor not connected0 = Sensor Ok, 1 = Sensor not connected1 Bit1.11 stateCRT
305[In12] Switch Feedback1 = On, 0 = Off1 Bit1.1 switchCW
305[In12] Switch 31 = On, 0 = Off1 Bit1.1 switchCRT
305[In12] Request Counter1 = Trigger1 Bit1.17 triggerCW
305[In12] Over-Heating Output1 = Over-Heating, 0 = No Over-Heating1 Bit1.5 alarmCRT
306[In12] Long Switch Feedback1 = On, 0 = Off1 Bit1.1 switchCW
306[In12] Switch 41 = On, 0 = Off1 Bit1.1 switchCRT
306[In12] Counter 8 BitsCounter (0..255)1 Byte5.10 counter pulses (0..255)CRT
306[In12] Counter 16 BitsCounter (0..65535)2 Bytes7.1 pulsesCRT
306[In12] Counter 32 BitsCounter (0..4.294.967.295)4 Bytes13.1 counter pulses (signed)CRT
306[In12] Over-Cooling Output1 = Over-Cooling, 0 = No Over-Cooling1 Bit1.5 alarmCRT
307[In12] Switch 51 = On, 0 = Off1 Bit1.1 switchCRT
308[In12] Increase/Decrease0 = Increase, 1 = Decrease1 Bit1.8 up/downCW
308[In12] Save Scene0 = Scene 1, 1 = Scene 21 Bit1.1 switchCRT
310[Fancoil 1] Switch Input1 = On, 0 = Off1 Bit1.1 switchCW
311[Fancoil 1] Switch Feedback1 = On, 0 = Off1 Bit1.1 switchCRT
312[Fancoil 1] Heating Valve % Input0% - 100%1 Byte5.1 percentage (0..100%)CW
312[Fancoil 1] Valve % Input0% - 100%1 Byte5.1 percentage (0..100%)CW
312[Fancoil 1] Valve On/Off Input1 = On, 0 = Off1 Bit1.1 switchCW
312[Fancoil 1] Heating Valve On/Off Input1 = On, 0 = Off1 Bit1.1 switchCW
313[Fancoil 1] Cooling Valve On/Off Input1 = On, 0 = Off1 Bit1.1 switchCW
313[Fancoil 1] Cooling Valve % Input0% - 100%1 Byte5.1 percentage (0..100%)CW
314[Fancoil 1] Valve % Feedback0% - 100%1 Byte5.1 percentage (0..100%)CRT
314[Fancoil 1] Heating Valve Feedback1 = On, 0 = Off1 Bit1.1 switchCRT
314[Fancoil 1] Heating Valve % Feedback0% - 100%1 Byte5.1 percentage (0..100%)CRT
314[Fancoil 1] Valve Feedback1 = On, 0 = Off1 Bit1.1 switchCRT
315[Fancoil 1] Cooling Valve Feedback1 = On, 0 = Off1 Bit1.1 switchCRT
315[Fancoil 1] Cooling Valve % Feedback0% - 100%1 Byte5.1 percentage (0..100%)CRT
316[Fancoil 1] Speed 1 Input1 = On, 0 = Off1 Bit1.1 switchCW
316[Fancoil 1] Speed % Input0% - 100%1 Byte5.1 percentage (0..100%)CW
317[Fancoil 1] Speed 2 Input1 = On, 0 = Off1 Bit1.1 switchCW
318[Fancoil 1] Speed 3 Input1 = On, 0 = Off1 Bit1.1 switchCW
319[Fancoil 1] Speed 1 Feedback1 = On, 0 = Off1 Bit1.1 switchCRT
319[Fancoil 1] Speed % Feedback0% - 100%1 Byte5.1 percentage (0..100%)CRT
320[Fancoil 1] Speed 2 Feedback1 = On, 0 = Off1 Bit1.1 switchCRT
321[Fancoil 1] Speed 3 Feedback1 = On, 0 = Off1 Bit1.1 switchCRT
322[Fancoil 1] Scene InputScene Control1 Byte18.1 scene controlCW
323[Fancoil 1] Valve Anti-Seize Protection Status1 = On, 0 = Off1 Bit1.1 switchCRT
336[T1] HVAC Mode Feedback1 Byte mode HVAC1 Byte20.102 HVAC modeCRT
337[T2] HVAC Mode Feedback1 Byte mode HVAC1 Byte20.102 HVAC modeCRT
338[T3] HVAC Mode Feedback1 Byte mode HVAC1 Byte20.102 HVAC modeCRT
339[T4] HVAC Mode Feedback1 Byte mode HVAC1 Byte20.102 HVAC modeCRT
340[T1] On/Off Feedback1 = On; 0 = Off1 Bit1.1 switchCRT
341[T1] On/Off Input1 = On; 0 = Off1 Bit1.1 switchCW
342[T1] Set-point FeedbackCurrent Set-point2 Bytes9.1 temperature (°C)CRT
343[T1] Set-point Input Set-point2 Bytes9.1 temperature (°C)CW
343[T1] Comfort Set-point InputComfort Set-point2 Bytes9.1 temperature (°C)CW
344[T1] Heating Valve OutputOutput (% Proportional - Integral)1 Byte5.1 percentage (0..100%)CRT
344[T1] Heating Valve OutputOutput (2-point with Hysteresis)1 Bit1.1 switchCRT
344[T1] Valve OutputOutput (% Proportional - Integral)1 Byte5.1 percentage (0..100%)CRT
344[T1] Valve OutputOutput (PWM Proportional - Integral)1 Bit1.1 switchCRT
344[T1] Heating Valve OutputOutput (PWM Proportional - Integral)1 Bit1.1 switchCRT
344[T1] Valve OutputOutput (2-point with Hysteresis)1 Bit1.1 switchCRT
345[T1] Cooling Valve OutputOutput (% Proportional - Integral)1 Byte5.1 percentage (0..100%)CRT
345[T1] Cooling Valve OutputOutput (PWM Proportional - Integral)1 Bit1.1 switchCRT
345[T1] Cooling Valve OutputOutput (2-point with Hysteresis)1 Bit1.1 switchCRT
346[T1] Temperature Sensor 1Input Temperature Sensor 12 Bytes9.1 temperature (°C)CW
347[T1] Temperature Sensor 2Input Temperature Sensor 22 Bytes9.1 temperature (°C)CW
348[T1] RHCC Status2 Bytes RHCC Status2 Bytes22.101 RHCC statusCRT
349[T1] Special HVAC mode Input 1 Byte mode HVAC1 Byte20.102 HVAC modeCW
350[T1] Special mode Economy0 = Off; 1 = On1 Bit1.1 switchCW
351[T1] Special mode Stand-by0 = Off; 1 = On1 Bit1.1 switchCW
352[T1] Special mode Protection0 = Off; 1 = On1 Bit1.1 switchCW
353[T1] Special mode Comfort0 = Off; 1 = On1 Bit1.1 switchCW
354[T1] Heating or Cooling mode Status0 = Cooling; 1 = Heating1 Bit1.1 switchCRT
355[T1] Heating or Cooling mode0 = Cooling; 1 = Heating1 Bit1.1 switchCW
356[T1] Window Alarm 1 Input0 = No Alarm; 1 = Alarm1 Bit1.5 alarmCW
357[T1] Window Alarm 2 Input0 = No Alarm; 1 = Alarm1 Bit1.5 alarmCW
358[T1] Window Alarm 3 Input0 = No Alarm; 1 = Alarm1 Bit1.5 alarmCW
359[T1] Window Alarm 4 Input0 = No Alarm; 1 = Alarm1 Bit1.5 alarmCW
360[T1] Fan On (Auto) / Off1 = On; 0 = Off1 Bit1.1 switchCW
361[T1] Fan Speed 1 Output1 = On; 0 = Off1 Bit1.1 switchCRT
361[T1] Fan Speed (%) OutputOutput (% Proportional - Integral)1 Byte5.1 percentage (0..100%)CRT
362[T1] Fan Speed 2 Output1 = On; 0 = Off1 Bit1.1 switchCRT
363[T1] Fan Speed 3 Output1 = On; 0 = Off1 Bit1.1 switchCRT
364[T1] Set Fan Speed 11 = Set Fan Speed1 Bit1.1 switchCW
364[T1] Set Fan Speed %Input (% Proportional - Integral)1 Byte5.1 percentage (0..100%)CW
365[T1] Set Fan Speed 21 = Set Fan Speed1 Bit1.1 switchCW
366[T1] Set Fan Speed 31 = Set Fan Speed1 Bit1.1 switchCW
367[T2] On/Off Feedback1 = On; 0 = Off1 Bit1.1 switchCRT
368[T2] On/Off Input1 = On; 0 = Off1 Bit1.1 switchCW
369[T2] Set-point FeedbackCurrent Set-point2 Bytes9.1 temperature (°C)CRT
370[T2] Set-point Input Set-point2 Bytes9.1 temperature (°C)CW
370[T2] Comfort Set-point InputComfort Set-point2 Bytes9.1 temperature (°C)CW
371[T2] Valve OutputOutput (2-point with Hysteresis)1 Bit1.1 switchCRT
371[T2] Valve OutputOutput (PWM Proportional - Integral)1 Bit1.1 switchCRT
371[T2] Valve OutputOutput (% Proportional - Integral)1 Byte5.1 percentage (0..100%)CRT
371[T2] Heating Valve OutputOutput (2-point with Hysteresis)1 Bit1.1 switchCRT
371[T2] Heating Valve OutputOutput (PWM Proportional - Integral)1 Bit1.1 switchCRT
371[T2] Heating Valve OutputOutput (% Proportional - Integral)1 Byte5.1 percentage (0..100%)CRT
372[T2] Cooling Valve OutputOutput (2-point with Hysteresis)1 Bit1.1 switchCRT
372[T2] Cooling Valve OutputOutput (PWM Proportional - Integral)1 Bit1.1 switchCRT
372[T2] Cooling Valve OutputOutput (% Proportional - Integral)1 Byte5.1 percentage (0..100%)CRT
373[T2] Temperature Sensor 1Input Temperature Sensor 12 Bytes9.1 temperature (°C)CW
374[T2] Temperature Sensor 2Input Temperature Sensor 22 Bytes9.1 temperature (°C)CW
375[T2] RHCC Status2 Bytes RHCC Status2 Bytes22.101 RHCC statusCRT
376[T2] Special HVAC mode Input1 Byte mode HVAC1 Byte20.102 HVAC modeCW
377[T2] Special mode Economy0 = Off; 1 = On1 Bit1.1 switchCW
378[T2] Special mode Stand-by0 = Off; 1 = On1 Bit1.1 switchCW
379[T2] Special mode Protection0 = Off; 1 = On1 Bit1.1 switchCW
380[T2] Special mode Comfort0 = Off; 1 = On1 Bit1.1 switchCW
381[T2] Heating or Cooling mode Status0 = Cooling; 1 = Heating1 Bit1.1 switchCRT
382[T2] Heating or Cooling mode0 = Cooling; 1 = Heating1 Bit1.1 switchCW
383[T2] Window Alarm 1 Input0 = No Alarm; 1 = Alarm1 Bit1.5 alarmCW
384[T2] Window Alarm 2 Input0 = No Alarm; 1 = Alarm1 Bit1.5 alarmCW
385[T2] Window Alarm 3 Input0 = No Alarm; 1 = Alarm1 Bit1.5 alarmCW
386[T2] Window Alarm 4 Input0 = No Alarm; 1 = Alarm1 Bit1.5 alarmCW
387[T2] Fan On (Auto) / Off1 = On; 0 = Off1 Bit1.1 switchCW
388[T2] Fan Speed 1 Output1 = On; 0 = Off1 Bit1.1 switchCRT
388[T2] Fan Speed (%) OutputOutput (% Proportional - Integral)1 Byte5.1 percentage (0..100%)CRT
389[T2] Fan Speed 2 Output1 = On; 0 = Off1 Bit1.1 switchCRT
390[T2] Fan Speed 3 Output1 = On; 0 = Off1 Bit1.1 switchCRT
391[T2] Set Fan Speed 11 = Set Fan Speed1 Bit1.1 switchCW
391[T2] Set Fan Speed %Input (% Proportional - Integral)1 Byte5.1 percentage (0..100%)CW
392[T2] Set Fan Speed 21 = Set Fan Speed1 Bit1.1 switchCW
393[T2] Set Fan Speed 31 = Set Fan Speed1 Bit1.1 switchCW
394[T3] On/Off Feedback1 = On; 0 = Off1 Bit1.1 switchCRT
395[T3] On/Off Input1 = On; 0 = Off1 Bit1.1 switchCW
396[T3] Set-point FeedbackCurrent Set-point2 Bytes9.1 temperature (°C)CRT
397[T3] Set-point Input Set-point2 Bytes9.1 temperature (°C)CW
397[T3] Comfort Set-point InputComfort Set-point2 Bytes9.1 temperature (°C)CW
398[T3] Valve OutputOutput (2-point with Hysteresis)1 Bit1.1 switchCRT
398[T3] Valve OutputOutput (PWM Proportional - Integral)1 Bit1.1 switchCRT
398[T3] Valve OutputOutput (% Proportional - Integral)1 Byte5.1 percentage (0..100%)CRT
398[T3] Heating Valve OutputOutput (2-point with Hysteresis)1 Bit1.1 switchCRT
398[T3] Heating Valve OutputOutput (PWM Proportional - Integral)1 Bit1.1 switchCRT
398[T3] Heating Valve OutputOutput (% Proportional - Integral)1 Byte5.1 percentage (0..100%)CRT
399[T3] Cooling Valve OutputOutput (2-point with Hysteresis)1 Bit1.1 switchCRT
399[T3] Cooling Valve OutputOutput (PWM Proportional - Integral)1 Bit1.1 switchCRT
399[T3] Cooling Valve OutputOutput (% Proportional - Integral)1 Byte5.1 percentage (0..100%)CRT
400[T3] Temperature Sensor 1Input Temperature Sensor 12 Bytes9.1 temperature (°C)CW
401[T3] Temperature Sensor 2Input Temperature Sensor 22 Bytes9.1 temperature (°C)CW
402[T3] RHCC Status2 Bytes RHCC Status2 Bytes22.101 RHCC statusCRT
403[T3] Special HVAC mode Input1 Byte mode HVAC1 Byte20.102 HVAC modeCW
404[T3] Special mode Economy0 = Off; 1 = On1 Bit1.1 switchCW
405[T3] Special mode Stand-by0 = Off; 1 = On1 Bit1.1 switchCW
406[T3] Special mode Protection0 = Off; 1 = On1 Bit1.1 switchCW
407[T3] Special mode Comfort0 = Off; 1 = On1 Bit1.1 switchCW
408[T3] Heating or Cooling mode Status0 = Cooling; 1 = Heating1 Bit1.1 switchCRT
409[T3] Heating or Cooling mode0 = Cooling; 1 = Heating1 Bit1.1 switchCW
410[T3] Window Alarm 1 Input0 = No Alarm; 1 = Alarm1 Bit1.5 alarmCW
411[T3] Window Alarm 2 Input0 = No Alarm; 1 = Alarm1 Bit1.5 alarmCW
412[T3] Window Alarm 3 Input0 = No Alarm; 1 = Alarm1 Bit1.5 alarmCW
413[T3] Window Alarm 4 Input0 = No Alarm; 1 = Alarm1 Bit1.5 alarmCW
414[T3] Fan On (Auto) / Off1 = On; 0 = Off1 Bit1.1 switchCW
415[T3] Fan Speed 1 Output1 = On; 0 = Off1 Bit1.1 switchCRT
415[T3] Fan Speed (%) OutputOutput (% Proportional - Integral)1 Byte5.1 percentage (0..100%)CRT
416[T3] Fan Speed 2 Output1 = On; 0 = Off1 Bit1.1 switchCRT
417[T3] Fan Speed 3 Output1 = On; 0 = Off1 Bit1.1 switchCRT
418[T3] Set Fan Speed 11 = Set Fan Speed1 Bit1.1 switchCW
418[T3] Set Fan Speed %Input (% Proportional - Integral)1 Byte5.1 percentage (0..100%)CW
419[T3] Set Fan Speed 21 = Set Fan Speed1 Bit1.1 switchCW
420[T3] Set Fan Speed 31 = Set Fan Speed1 Bit1.1 switchCW
421[T4] On/Off Feedback1 = On; 0 = Off1 Bit1.1 switchCRT
422[T4] On/Off Input1 = On; 0 = Off1 Bit1.1 switchCW
423[T4] Set-point FeedbackCurrent Set-point2 Bytes9.1 temperature (°C)CRT
424[T4] Set-point Input Set-point2 Bytes9.1 temperature (°C)CW
424[T4] Comfort Set-point InputComfort Set-point2 Bytes9.1 temperature (°C)CW
425[T4] Valve OutputOutput (2-point with Hysteresis)1 Bit1.1 switchCRT
425[T4] Valve OutputOutput (PWM Proportional - Integral)1 Bit1.1 switchCRT
425[T4] Valve OutputOutput (% Proportional - Integral)1 Byte5.1 percentage (0..100%)CRT
425[T4] Heating Valve OutputOutput (2-point with Hysteresis)1 Bit1.1 switchCRT
425[T4] Heating Valve OutputOutput (PWM Proportional - Integral)1 Bit1.1 switchCRT
425[T4] Heating Valve OutputOutput (% Proportional - Integral)1 Byte5.1 percentage (0..100%)CRT
426[T4] Cooling Valve OutputOutput (2-point with Hysteresis)1 Bit1.1 switchCRT
426[T4] Cooling Valve OutputOutput (PWM Proportional - Integral)1 Bit1.1 switchCRT
426[T4] Cooling Valve OutputOutput (% Proportional - Integral)1 Byte5.1 percentage (0..100%)CRT
427[T4] Temperature Sensor 1Input Temperature Sensor 12 Bytes9.1 temperature (°C)CW
428[T4] Temperature Sensor 2Input Temperature Sensor 22 Bytes9.1 temperature (°C)CW
429[T4] RHCC Status2 Bytes RHCC Status2 Bytes22.101 RHCC statusCRT
430[T4] Special HVAC mode Input1 Byte mode HVAC1 Byte20.102 HVAC modeCW
431[T4] Special mode Economy0 = Off; 1 = On1 Bit1.1 switchCW
432[T4] Special mode Stand-by0 = Off; 1 = On1 Bit1.1 switchCW
433[T4] Special mode Protection0 = Off; 1 = On1 Bit1.1 switchCW
434[T4] Special mode Comfort0 = Off; 1 = On1 Bit1.1 switchCW

First 1000 of 1212 group objects shown. Download the .knxprod for the full list.

Parameters (600)
ParameterTypeDefault
RASTRO_ETSunsignedInt 0…25516
MODELOunsignedInt 0…2550
Transmission and switching delay after recovering bus voltage (sec)unsignedInt 2…2552
NUM_FANCOILSunsignedInt 0…2550
Actuator as Fan-CoilunsignedInt 0…10
NUMPIPESunsignedInt 0…2550
VALVETYPEunsignedInt 0…2550
ch A operating modelist1-ch Blind/Roller Actuator
ch B operating modelist1-ch Blind/Roller Actuator
GENERAL_OPERATING_MODE_2unsignedInt 0…2551
GENERAL_OPERATING_MODE_3unsignedInt 0…2551
FANCOIL_MODESunsignedInt 0…2551
GENERAL_OPERATING_MODE_5unsignedInt 0…2551
GENERAL_OPERATING_MODE_6unsignedInt 0…2551
GENERAL_OPERATING_MODE_7unsignedInt 0…2551
Central ControllistNo
PWM Frequencylist300 Hz
Dimmer Configurationlist4-channel Dimmer
Function of InputlistNot assigned
Debounce timelist10 msec
Distinction between Short and Long pressunsignedInt 0…10
Contact typelistNormally Open
Long press afterlist0,3 sec
Number of objects for Short/Long presslist1
Short presslistOn
Long presslistOn
Cyclical transmissionlistNo
Action on Closing the contactlistOn
Action on Opening the contactlistOn
Transmit status after recovering bus voltageunsignedInt 0…10
Cycle base timelist1 sec
Factor (Total time = Base x Factor)unsignedInt 0…2557
Dimming FunctionalitylistDimming and Switching
Action on presslistDim Brighter / Darker
Long presslistDim Brighter / Darker
Save Scene on Long pressunsignedInt 0…10
Maximum time between two presslist0,5 sec
Number of presslist2
Press 1 actionlistOn
Press 2 actionlistOn
Press 3 actionlistOn
Press 4 actionlistOn
Number of objectslist2
Functional Constructionlist1 Pushbutton
Shutter FunctionalitylistShort = Step, Long = Move
Long presslistMove Up
Short presslistStep Down
Value type on Short presslist1 Bit
Value type on Long presslist1 Bit
Signlist+
Integer partunsignedInt 0…990
Decimal partunsignedInt 0…990
2 Bytes valueunsignedInt 0…655350
2 Bytes signed valuesignedInt -32768…327670
4 Bytes valueunsignedInt 0…42949672950
1 Bit valuelist0
2 Bits valuelist"00"
1 Byte valueunsignedInt 0…2550
Value type on presslist1 Bit
Type of Scene Controllist8-Bit Scene
SceneunsignedInt 1…641
Short presslistCall
Save ScenelistNo
Scene 1/2unsignedInt 1…21
Data Counter widthlist8
Start value (0..255)unsignedInt 0…2550
Start value (0..65535)unsignedInt 0…655350
Start value (0..4.294.967.295)unsignedInt 0…42949672950
Temperature sending base timelist1 min
Temperature change to sendunsignedInt 5…2005
Protection AlarmslistNo Protection
HysteresisunsignedInt 0…500
Over-Heating Temperaturelist-30
Over-Cooling Temperaturelist-30
Temperature Functionality enabled after recovering bus voltageunsignedInt 0…11
Temperature Sensor calibration valuelist0
Number of colours to togglelist9 colours
Add Black colour (Off)unsignedInt 0…10
Colour Brightness value (%)unsignedInt 0…100100
Output object typelistRGB object
IN0_EMPTY_2unsignedInt 0…25550
IN0_EMPTY_3unsignedInt 0…25550
IN0_EMPTY_4unsignedInt 0…25550
IN0_EMPTY_5unsignedInt 0…25550
IN0_EMPTY_6unsignedInt 0…25550
IN0_EMPTY_7unsignedInt 0…25550
IN0_EMPTY_8unsignedInt 0…25550
IN0_EMPTY_9unsignedInt 0…25550
IN0_EMPTY_10unsignedInt 0…25550
IN0_EMPTY_11unsignedInt 0…25550
IN0_EMPTY_12unsignedInt 0…25550
IN0_OBJECT_TYPE_MOV_DETunsignedInt 0…25550
IN0_CYCLIC_DETunsignedInt 0…25550
IN0_CYCLIC_LAGunsignedInt 0…25550
IN0_TIME_CYC_BASE_DETunsignedInt 0…25550
IN0_TIME_CYC_FACTOR_DETunsignedInt 0…25550
IN0_SEND_SW_DETunsignedInt 0…25550
IN0_SEND_SW_LAGunsignedInt 0…25550
IN0_SEND_PER_DETunsignedInt 0…25550
IN0_SEND_PER_LAGunsignedInt 0…25550
IN0_SEND_SCENE_DETunsignedInt 0…25550
IN0_SEND_SCENE_LAGunsignedInt 0…25550
Object typelistSwitch
Cyclical sending after detectionunsignedInt 0…10
Cyclical sending after lag timeunsignedInt 0…10
Time Base for cyclical transmissionlist10 sec
Time Factor for cyclical transmissionunsignedInt 1…2551
Send after detectionlistOn
Send after lag timelistOff
Send after detectionlist100%
Send after detectionlistScene 1
Send after lag timelistScene 2
Send after detectionlistComfort
Send after lag timelistStand-by
Number of objectslist1
IN1_OBJECT_TYPE_MOV_DETunsignedInt 0…25550
IN1_CYCLIC_DETunsignedInt 0…25550
IN1_CYCLIC_LAGunsignedInt 0…25550
IN1_TIME_CYC_BASE_DETunsignedInt 0…25550
IN1_TIME_CYC_FACTOR_DETunsignedInt 0…25550
IN1_SEND_SW_DETunsignedInt 0…25550
IN1_SEND_SW_LAGunsignedInt 0…25550
IN1_SEND_PER_DETunsignedInt 0…25550
IN1_SEND_PER_LAGunsignedInt 0…25550
IN1_SEND_SCENE_DETunsignedInt 0…25550
IN1_SEND_SCENE_LAGunsignedInt 0…25550
IN2_OBJECT_TYPE_MOV_DETunsignedInt 0…25550
IN2_CYCLIC_DETunsignedInt 0…25550
IN2_CYCLIC_LAGunsignedInt 0…25550
IN2_TIME_CYC_BASE_DETunsignedInt 0…25550
IN2_TIME_CYC_FACTOR_DETunsignedInt 0…25550
IN2_SEND_SW_DETunsignedInt 0…25550
IN2_SEND_SW_LAGunsignedInt 0…25550
IN2_SEND_PER_DETunsignedInt 0…25550
IN2_SEND_PER_LAGunsignedInt 0…25550
IN2_SEND_SCENE_DETunsignedInt 0…25550
IN2_SEND_SCENE_LAGunsignedInt 0…25550
IN3_OBJECT_TYPE_MOV_DETunsignedInt 0…25550
IN3_CYCLIC_DETunsignedInt 0…25550
IN3_CYCLIC_LAGunsignedInt 0…25550
IN3_TIME_CYC_BASE_DETunsignedInt 0…25550
IN3_TIME_CYC_FACTOR_DETunsignedInt 0…25550
IN3_SEND_SW_DETunsignedInt 0…25550
IN3_SEND_SW_LAGunsignedInt 0…25550
IN3_SEND_PER_DETunsignedInt 0…25550
IN3_SEND_PER_LAGunsignedInt 0…25550
IN3_SEND_SCENE_DETunsignedInt 0…25550
IN3_SEND_SCENE_LAGunsignedInt 0…25550
Enable Thermostat 1unsignedInt 0…10
ModelistCooling Thermostat
Reference Temperature SourcelistOne source
Thermostat always ONunsignedInt 0…10
status after recovering bus voltagelistOff
Enable Turn-on Thermostat when Special telegram arrivesunsignedInt 0…10
Send Thermostat Set-point after recovering bus voltageunsignedInt 0…10
Enable automatic Mode changeunsignedInt 0…10
Mode after recovering bus voltagelistCooling Thermostat
Control objectlistDifferent objects for Heating and Cooling
Set-point modelistAbsolute Set-point mode
Initial Set-point after recovering bus voltageunsignedInt 5…4524
Save Set-point after Mode change via objectunsignedInt 0…10
Mode after recovering bus voltagelistComfort
Enable 1-Bit Mode objectslistDisable
Enable Window ProtectionunsignedInt 0…10
Comfort Set-pointunsignedInt 5…4522
Offset for Stand-by Set-point modelist-20
Offset for Economy Set-point modelist-40
Freezing Protection Set-pointunsignedInt 0…158
Offset for Stand-by Set-point modeunsignedInt 0…9920
Offset for Economy Set-point modeunsignedInt 0…9940
Over-Temperature Protection Set-pointunsignedInt 30…4540
Regulation modelist2-point control with Hysteresis
Higher HysteresisunsignedInt 5…4510
Lower HysteresisunsignedInt 5…4510
Forwarding period (0=Disable)unsignedInt 0…2550
PWM typelistPWM (1 Bit)
PI Cycle TimeunsignedInt 0…25515
Proportional bandunsignedInt 0…155
Attenuation factorunsignedInt 0…9931
Maximum Integral component (%)unsignedInt 0…9921
Thermostat TypelistThermostat
Fan-Coil TypelistOn/Off Control
Valve control typelistOn/Off Control
Heat / Cool Systemlist2 pipes
"Fan On/Off" object ON after recovering bus voltageunsignedInt 0…11
Upper Hysteresis to activate Speed 1unsignedInt 5…4510
Lower Hysteresis to activate Speed 1unsignedInt 5…4510
Offset from Set-point to activate Speed 2list-30
Offset from Set-point to activate Speed 3list-50
Offset from Set-point to activate Speed 2unsignedInt 0…10030
Offset from Set-point to activate Speed 3unsignedInt 0…10050
Fan-Coil Speed Output objectslistOnly one active each Speed
Valve independent controlunsignedInt 0…10
Upper Hysteresis for ValveunsignedInt 5…4510
Lower Hysteresis for ValveunsignedInt 5…4510
Enable Thermostat 2unsignedInt 0…10
Enable Thermostat 3unsignedInt 0…10
Enable Thermostat 4unsignedInt 0…10
Send Fan-Coil status after recovering bus voltageunsignedInt 0…10
Valve and Fan FeedbacklistNo
Output polaritylistNormally Open contact
PI Cycle TimeunsignedInt 1…25515
Valve Movement Time (0%..100%)unsignedInt 1…6553530
Extra Movement at 0% and 100%unsignedInt 0…2550
Reversion Pause Time (msec)unsignedInt 500…5000500
Cyclic FeedbackunsignedInt 0…10
Time to send FeedbackunsignedInt 60…360060
FAN0_VALVE_3WAY_ENABLE_MOVEINFOunsignedInt 0…2550
Minimum Time between Valve switchesunsignedInt 0…36000
Minimum Time for Mode changeunsignedInt 0…36000
FAN0_VALVE_3WAY_MIN_PORCunsignedInt 0…2550
Minimum % change to applyunsignedInt 0…1000
FAN0_VALVE_3WAY_NUM_RESET_POSunsignedInt 0…655350
Fan-Coil status after recovering bus voltagelistOff
FAN0_FAN_status_ABRVunsignedInt 0…2550
FAN0_VALVE_status_ABRVunsignedInt 0…2550
FAN0_3WAY_status_ABRVunsignedInt 0…2550
Reaction after bus failurelistNo reaction
Enable ScenesunsignedInt 0…10
Scene 1listScene 1
Fan-Coil Status Scene 1listOff
FAN0_SCENE_FAN_SPEED_1unsignedInt 0…2550
Scene 2listScene 2
Fan-Coil Status Scene 2listOff
FAN0_SCENE_FAN_SPEED_2unsignedInt 0…2550
Scene 3listScene 3
Fan-Coil Status Scene 3listOff
FAN0_SCENE_FAN_SPEED_3unsignedInt 0…2550
Scene 4listScene 4
Fan-Coil Status Scene 4listOff
FAN0_SCENE_FAN_SPEED_4unsignedInt 0…2550
Scene 5listScene 5
Fan-Coil Status Scene 5listOff
FAN0_SCENE_FAN_SPEED_5unsignedInt 0…2550
"Fan Speed" object typelistOn/Off object
Fan Speed output modelistOnly one relay active each Speed
Time to change Fan SpeedunsignedInt 3…1003
FAN0_FORCED_ABRVunsignedInt 0…2550
Disable Manual ControlunsignedInt 0…10
Enable Central FunctionunsignedInt 0…10
Central FunctionlistNo reaction
FAN0_CENTRAL_SPunsignedInt 0…2550
Disable relay switching with zero-cross controlunsignedInt 0…10
Switch FeedbacklistNo
Polarity Switch Feedback objectlistClosed = 1, Open = 0
LI0_STATUS_DELAYunsignedInt 0…2550
LI0_STATUS_DELAY_BASEunsignedInt 0…2550
LI0_STATUS_DELAY_FACTORunsignedInt 0…2550
Reaction after bus failurelistOpen contact
"Switch On/Off" object after recovering bus voltagelistSet object to 0
Enable Time FunctionunsignedInt 0…10
Time FunctionlistStaircase Light Time Switch
"Disable Time Function" object after recovering bus voltagelist0: Enable Time Function
Enable Preset FunctionunsignedInt 0…10
Enable Scenes FunctionunsignedInt 0…10
Enable Logical FunctionunsignedInt 0…10
Enable Forced FunctionunsignedInt 0…10
Enable Threshold FunctionunsignedInt 0…10
Staircase Light Time Switch timing (sec)unsignedInt 0…655350
Timer is retriggerableunsignedInt 0…10
Staircase Light Time Switch early Switch-offlist1 = On, 0 = Off
Pre-warning before end of timelistNo
Pre-warning time (sec)unsignedInt 0…6553516
Staircase time changeable via objectunsignedInt 0…10
ON Delay Time (sec)unsignedInt 0…655351
OFF Delay Time (sec)unsignedInt 0…655351
Flashing when "Time Switch" object islistOn (1)
Flash On time (sec)unsignedInt 0…655355
Flash Off time (sec)unsignedInt 0…655355
Reaction on Preset 1 (telegram 0)listNo reaction
Reaction on Preset 2 (telegram 1)listNo reaction
Preset can be set via busunsignedInt 0…10
Scene 1 valuelistOff
Scene 2 valuelistOff
Scene 3 valuelistOff
Scene 4 valuelistOff
Scene 5 valuelistOff
Enable Logical connection 1unsignedInt 0…11
Logical connection 1 FunctionlistAND
Logical connection 1 InvertedunsignedInt 0…10
"Logical connection 1" object after recovering bus voltagelistTrue
Enable Logical connection 2unsignedInt 0…10
Logical connection 2 FunctionlistAND
Logical connection 2 InvertedunsignedInt 0…10
"Logical connection 2" object after recovering bus voltagelistFalse
"Forced" object typelist1 Bit
"Forced" object polaritylist1: Off
"Forced" object after recovering bus voltagelistNot Forced
Data type of object "Threshold Input"list1 Byte (0..255)
Change Threshold 1 over the busunsignedInt 0…10
Threshold value 1 (0..255)unsignedInt 0…255255
Threshold value 2 (0..255)unsignedInt 0…2550
Threshold value 1 (0..65535)unsignedInt 0…6553550000
Threshold value 2 (0..65535)unsignedInt 0…655350
Threshold values define HysteresisunsignedInt 0…10
"Threshold Input" after recovering bus voltageunsignedInt 0…2550
"Threshold Input" after recovering bus voltageunsignedInt 0…655350
Object value < Threshold value 1listNo reaction
Object value > Threshold value 2listNo reaction
Threshold 1 < Object value < Threshold 2listNo reaction
Output Line Phase respect ReferencelistSame Phase as Reference
Type of DevicelistVenetian Blind
Reaction after bus failurelistStop
Behavior after recovering bus voltagelistNo action (last position)
Blind position (0..100%) after recovering bus voltageunsignedInt 0…1000
Slats position after recovering bus voltage (%)unsignedInt 0…1000
Extra time for Up movement (%)unsignedInt 0…500
Forced vs Weather Alarm Prioritylist1 - Forced operation, 2 - Weather Alarm
Reversion Pause time (msec)unsignedInt 499…5000500
Step operation possiblelistNo (only Stop)
Step time (x 0,1 sec)unsignedInt 2…60010
Blind Movement time (sec)unsignedInt 1…360010
Slats Movement Time (x 0,1sec)unsignedInt 2…60020
Time to send "Blind position Feedback" (sec)unsignedInt 60…360060
Time to send "Slats position Feedback" (sec)unsignedInt 60…360060
Enable "Movement Feedback" objectunsignedInt 0…10
Enable Weather AlarmsunsignedInt 0…10
Enable "Wind Alarm 1" objectunsignedInt 0…10
Enable "Wind Alarm 2" objectunsignedInt 0…10
Enable "Wind Alarm 3" objectunsignedInt 0…10
Enable "Rain Alarm" objectunsignedInt 0…10
Enable "Frost Alarm" objectunsignedInt 0…10
Enable Wind Alarm WatchdogunsignedInt 0…10
Wind Alarm Watchdog time (sec)unsignedInt 10…655353600
Enable Rain Alarm WatchdogunsignedInt 0…10
Rain Alarm Watchdog time (sec)unsignedInt 10…6553510
Enable Frost Alarm WatchdogunsignedInt 0…10
Frost Alarm Watchdog time (sec)unsignedInt 10…6553510
Behavior when starting Wind AlarmlistNo action
Behavior when finishing Wind AlarmlistNo action
Behavior when starting Rain AlarmlistNo action
Behavior when finishing Rain AlarmlistNo action
Behavior when starting Frost AlarmlistNo action
Behavior when finishing Frost AlarmlistNo action
Weather Alarms prioritylistWind > Rain > Frost
Enable Sun ProtectionunsignedInt 0…10
Type of objectlist1-Bit On/Off
Sun Protection object polaritylist1: Sun Protection On
Lux value to Start ProtectionunsignedInt 1…36001000
Lux value to Finish ProtectionunsignedInt 1…3600500
Delay time to Start Sun Protection (sec)unsignedInt 1…36001
Behavior when starting Sun ProtectionlistNo action
ScenelistScene 1
Position (%)unsignedInt 0…1000
Slats position (%)unsignedInt 0…1000
Delay time to Finish Sun Protection (sec)unsignedInt 1…36001
Behavior when finishing Sun ProtectionlistNo action
Scene 1 Position (%)unsignedInt 0…1000
Scene 2 Position (%)unsignedInt 0…1000
Scene 3 Position (%)unsignedInt 0…1000
Scene 4 Position (%)unsignedInt 0…1000
Scene 5 Position (%)unsignedInt 0…1000
Scene 6listScene 6
Scene 6 Position (%)unsignedInt 0…1000
Scene 7listScene 7
Scene 7 Position (%)unsignedInt 0…1000
Scene 8listScene 8
Scene 8 position (%)unsignedInt 0…1000
Scene 1 Slats Position (%)unsignedInt 0…1000
Scene 2 Slats Position (%)unsignedInt 0…1000
Scene 3 Slats Position (%)unsignedInt 0…1000
Scene 4 Slats Position (%)unsignedInt 0…1000
Scene 5 Slats Position (%)unsignedInt 0…1000
Scene 6 Slats Position (%)unsignedInt 0…1000
Scene 7 Slats Position (%)unsignedInt 0…1000
Scene 8 Slats Position (%)unsignedInt 0…1000
Forced object after recovering bus voltagelistNot Forced
Fabric loosen time (sec)unsignedInt 0…2550
Enable "Blind position Feedback" objectunsignedInt 0…10
Enable "Slats position Feedback" objectunsignedInt 0…10
Central Function Position (%)unsignedInt 0…1000
Central Function Slats Position (%)unsignedInt 0…1000
Pre-warning time (sec)unsignedInt 0…2400
Timer time delay (sec)unsignedInt 1…6553560
Minimum Brightness (%)unsignedInt 1…751
Maximum Brightness (%)unsignedInt 25…100100
Soft Switch-on Time (x 0,1sec)unsignedInt 1…250010
Soft Switch-off Time (x 0,1sec)unsignedInt 1…250010
Switch-on modelistSwitch-on at last brightness
Switch-on Brightness value (%)unsignedInt 3…1003
Central Function Brightness value (%)unsignedInt 3…10050
Action after recovering Bus supplylistSwitch-Off
Brightness after recovering bus supply (%)unsignedInt 3…100100
Switch-on Ramp time (sec)unsignedInt 1…655351
On time (sec)unsignedInt 1…655351
Switch-off Ramp time (sec)unsignedInt 1…655351
Off time (sec)unsignedInt 1…655351
Number of Scenes attendedlist8
Scene 9listScene 9
Scene 10listScene 10
Scene 11listScene 11
Scene 12listScene 12
Scene 13listScene 13
Scene 14listScene 14
Scene 15listScene 15
Scene 16listScene 16
Brightness (%) Scene 1unsignedInt 0…1000
Brightness (%) Scene 2unsignedInt 0…1000
Brightness (%) Scene 3unsignedInt 0…1000
Brightness (%) Scene 4unsignedInt 0…1000
Brightness (%) Scene 5unsignedInt 0…1000
Brightness (%) Scene 6unsignedInt 0…1000
Brightness (%) Scene 7unsignedInt 0…1000
Brightness (%) Scene 8unsignedInt 0…1000
Brightness (%) Scene 9unsignedInt 0…1000
Brightness (%) Scene 10unsignedInt 0…1000
Brightness (%) Scene 11unsignedInt 0…1000
Brightness (%) Scene 12unsignedInt 0…1000
Brightness (%) Scene 13unsignedInt 0…1000
Brightness (%) Scene 14unsignedInt 0…1000
Brightness (%) Scene 15unsignedInt 0…1000
Brightness (%) Scene 16unsignedInt 0…1000
Dimming Speed (from 0% to 100% x 0,1sec)unsignedInt 1…250050
Fade Time ( x 0,1sec)unsignedInt 1…250020
Behavior on incoming Dimming ValuelistGo gradually
Off status Brightness (%)unsignedInt 0…1000
Action after recovering LED SupplylistSwitch-on at last brightness
Brightness after recovering LED Supply (%)unsignedInt 3…100100
DM0_EMPTY_12unsignedInt 0…2551
DM0_EMPTY_13unsignedInt 0…2551
DM0_EMPTY_14unsignedInt 0…2551
DM0_EMPTY_15unsignedInt 0…655351
DM0_EMPTY_16unsignedInt 0…655351
DM0_EMPTY_17unsignedInt 0…655351
DM0_EMPTY_18unsignedInt 0…655351
R channelunsignedInt 0…1003
G channelunsignedInt 0…1003
B channelunsignedInt 0…1003
W channelunsignedInt 0…1003
R channelunsignedInt 0…100100
G channelunsignedInt 0…100100
B channelunsignedInt 0…100100
W channelunsignedInt 0…100100
Scene (1-64)listScene 1
Sequence number (1-5)listSequence 1
Colour transition Speed (from 0% to 100% x 0,1sec)unsignedInt 1…250020
Behavior on incoming Absolute or Colour valuelistGo gradually
R channelunsignedInt 0…1000
G channelunsignedInt 0…1000
B channelunsignedInt 0…1000
W channelunsignedInt 0…1000
RGB_COLORRGB_OFF_VALUE_BYTE_WHITEunsignedInt 0…2550
RGB_REL_DIM_OFF_VALUE_BYTE_REDunsignedInt 0…2550
RGB_REL_DIM_OFF_VALUE_BYTE_GREENunsignedInt 0…2550
RGB_REL_DIM_OFF_VALUE_BYTE_BLUEunsignedInt 0…2550
RGB_REL_DIM_OFF_VALUE_BYTE_WHITEunsignedInt 0…2550
RGB_ABS_DIM_OFF_VALUE_BYTE_REDunsignedInt 0…2550
RGB_ABS_DIM_OFF_VALUE_BYTE_GREENunsignedInt 0…2550
RGB_ABS_DIM_OFF_VALUE_BYTE_BLUEunsignedInt 0…2550
RGB_ABS_DIM_OFF_VALUE_BYTE_WHITEunsignedInt 0…2550
Number of Scenes attendedlistAll Scenes
White Colour only on W channelunsignedInt 0…10
RGB_EMPTY_2unsignedInt 0…2550
RGB_EMPTY_3unsignedInt 0…2550
RGB_EMPTY_4unsignedInt 0…2550
RGB_EMPTY_5unsignedInt 0…2550
RGB_EMPTY_6unsignedInt 0…2550
RGB_EMPTY_7unsignedInt 0…2550
RGB_EMPTY_8unsignedInt 0…2550
RGB_EMPTY_9unsignedInt 0…2550
RGB_EMPTY_10unsignedInt 0…2550
RGB_EMPTY_11unsignedInt 0…655350
RGB_EMPTY_12unsignedInt 0…655350
RGB_EMPTY_13unsignedInt 0…655350
POWER_FAIL_RGBunsignedInt 0…2550
POWER_FAULT_SEQUENCE_RGBunsignedInt 0…2550
SECUENCIADOR_TIPO_CARGA_CANAL_1unsignedInt 0…2550
SECUENCIADOR_TIPO_CARGA_CANAL_2unsignedInt 0…2550
SECUENCIADOR_TIPO_CARGA_CANAL_3unsignedInt 0…2550
SECUENCIADOR_TIPO_CARGA_CANAL_4unsignedInt 0…2550
SECUENCIADOR_TIPO_CARGA_CANAL_5unsignedInt 0…2550
SECUENCIADOR_TIPO_CARGA_CANAL_6unsignedInt 0…2550
SECUENCIADOR_TIPO_CARGA_CANAL_7unsignedInt 0…2550
SECUENCIADOR_TIPO_CARGA_CANAL_8unsignedInt 0…2550
Enable Sequence 1unsignedInt 0…10
Enable Sequence 2unsignedInt 0…10
Enable Sequence 3unsignedInt 0…10
Enable Sequence 4unsignedInt 0…10
Enable Sequence 5unsignedInt 0…10
Do this SequencelistOnce
Number of Stepslist1 Step
Step time (x 0,1 sec)unsignedInt 1…65535100
R channelunsignedInt 0…2550
G channelunsignedInt 0…2550
B channelunsignedInt 0…2550
W channelunsignedInt 0…2550
"Disable Logic" object after recovering bus voltagelistEnable (0)
Type of LogiclistNot assigned
Boolean functionlistAND
InvertedunsignedInt 0…10
Reaction with event on inputlistExecute logic
Value of Input after recovering bus voltagelistSet Input to 0
Input enabledunsignedInt 0…10
Output datatypelist1 Bit
Sending conditionlistOn change
Send when TrueunsignedInt 0…10
Value when TrueunsignedInt 0…42949672950
Send when FalseunsignedInt 0…10
Value when FalseunsignedInt 0…42949672950
Factor (Total time = base x Factor)unsignedInt 0…2550

First 500 of 600 parameters shown. Download the .knxprod for the full list.

Version history

ApplicationApp noFingerprintFirst seenSizeFile
DINUY_IRKNT044 0.0 latest$200F1CE12026-11-25645 KBDownload

About this file

This is the official ETS product database for the Dinuy Act 4ch/2ch switch/blind + RGBW dimmer + inputs (IR KNT 044), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.