| 1 | General | Alive Beacon (0-Active) | 1 Bit | 1.17 trigger | CRT |
| 1 | General | Alive Beacon (1-Active) | 1 Bit | 1.17 trigger | CRT |
| 2 | Thermostat | Disabling Function (1-Disable, 0-Enable) | 1 Bit | 1.2 boolean | CW |
| 3 | Proximity | Approach Switching Value (0-Active) | 1 Bit | 1.5 alarm | CRT |
| 3 | Proximity | Approach Switching Value (1-Active) | 1 Bit | 1.5 alarm | CRT |
| 4 | Ambient | Darkness Switching Value (0-Active) | 1 Bit | 1.1 switch | CRT |
| 4 | Ambient | Darkness Switching Value (1-Active) | 1 Bit | 1.1 switch | CRT |
| 5 | Humidity | Internal Value (%) | 2 Bytes | 9.7 humidity (%) | CRT |
| 6 | Humidity | External Value (%) | 2 Bytes | 9.7 humidity (%) | CWTU |
| 7 | CO2 | Internal Value (ppm) | 2 Bytes | 9.8 parts/million (ppm) | CRT |
| 8 | CO2 | External Value (ppm) | 2 Bytes | 9.8 parts/million (ppm) | CWTU |
| 9 | CO2 | Air Quality Index(0-Off, 1-Poor, 2-Satisfactory, 3-Good) | 1 Byte | | CRT |
| 10 | CO2 | Poor Level Switching (1-Active) | 1 Bit | 1.5 alarm | CRT |
| 10 | CO2 | Poor Level Switching (0-Active) | 1 Bit | 1.5 alarm | CRT |
| 11 | Temperature | Actual Temperature (°C) | 2 Bytes | 9.1 temperature (°C) | CRT |
| 12 | Temperature | External Temperature (°C) | 2 Bytes | 9.1 temperature (°C) | CWTU |
| 13 | Thermostat | Heating/Cooling Switchover (1-Heat, 0-Cool) | 1 Bit | 1.100 cooling/heating | CWU |
| 14 | Thermostat | Heating/Cooling Status (1-Heat, 0-Cool) | 1 Bit | 1.100 cooling/heating | CRT |
| 15 | Thermostat | Heating 2 Point Control Value | 1 Bit | 1.1 switch | CRT |
| 15 | Thermostat | Heating PWM Control Value | 1 Bit | 1.1 switch | CRT |
| 15 | Thermostat | Heating PI Control Value | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 16 | Thermostat | Cooling 2 Point Control Value | 1 Bit | 1.1 switch | CRT |
| 16 | Thermostat | Cooling PWM Control Value | 1 Bit | 1.1 switch | CRT |
| 16 | Thermostat | Cooling PI Control Value | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 17 | Thermostat | Heating/Cooling 2 point Control Value | 1 Bit | 1.1 switch | CRT |
| 17 | Thermostat | Heating/Cooling PWM Control Value | 1 Bit | 1.1 switch | CRT |
| 17 | Thermostat | Heating/Cooling PI Control Value | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 18 | Thermostat | Heating Indication | 1 Bit | 1.11 state | CRT |
| 19 | Thermostat | Cooling Indication | 1 Bit | 1.11 state | CRT |
| 20 | Thermostat | Additional Heating Controller Disable | 1 Bit | 1.3 enable | CWU |
| 21 | Thermostat | Additional Heating Controller Status | 1 Bit | 1.3 enable | CRT |
| 22 | Thermostat | Additional Heating Control Value | 1 Bit | 1.1 switch | CRT |
| 23 | Thermostat | Additional Cooling Controller Disable | 1 Bit | 1.3 enable | CWU |
| 24 | Thermostat | Additional Cooling Controller Status | 1 Bit | 1.3 enable | CRT |
| 25 | Thermostat | Additional Cooling Control Value | 1 Bit | 1.1 switch | CRT |
| 26 | Thermostat | Operating Mode | 1 Byte | 20.102 HVAC mode | CWU |
| 27 | Thermostat | Operating Mode Status | 1 Byte | 20.102 HVAC mode | CRT |
| 28 | Thermostat | Operating Mode (prev/next) | 1 Bit | 1.2 boolean | CWU |
| 29 | Thermostat | Comfort Mode | 1 Bit | 1.11 state | CWTU |
| 30 | Thermostat | Comfort Mode Status | 1 Bit | 1.11 state | CRT |
| 31 | Thermostat | Standby Mode | 1 Bit | 1.11 state | CWTU |
| 32 | Thermostat | Standby Mode Status | 1 Bit | 1.11 state | CRT |
| 33 | Thermostat | Night Mode | 1 Bit | 1.11 state | CWTU |
| 34 | Thermostat | Night Mode Status | 1 Bit | 1.11 state | CRT |
| 35 | Thermostat | Protection Mode | 1 Bit | 1.11 state | CWTU |
| 36 | Thermostat | Protection Mode Status | 1 Bit | 1.11 state | CRT |
| 37 | Thermostat | Setpoint Control | 2 Bytes | 9.1 temperature (°C) | CWU |
| 38 | Thermostat | Setpoint Status | 2 Bytes | 9.1 temperature (°C) | CRT |
| 39 | Thermostat | Setpoint (-/+) | 1 Bit | 1.7 step | CWU |
| 40 | Thermostat | Fan Speed Enumerated (1,2,3) | 1 Byte | 5.100 fan stage (0..255) | CT |
| 40 | Thermostat | Fan Speed Enumerated (1) | 1 Byte | 5.100 fan stage (0..255) | CT |
| 40 | Thermostat | Fan Speed Enumerated (1,2) | 1 Byte | 5.100 fan stage (0..255) | CT |
| 40 | Thermostat | Fan Speed Enumerated (1,2,3,4) | 1 Byte | 5.100 fan stage (0..255) | CT |
| 40 | Thermostat | Fan Speed Enumerated (1,2,3,4,5) | 1 Byte | 5.100 fan stage (0..255) | CT |
| 40 | Thermostat | Fan Speed Enumerated (0,1,2,3) | 1 Byte | 5.100 fan stage (0..255) | CT |
| 40 | Thermostat | Fan Speed Enumerated (0,1) | 1 Byte | 5.100 fan stage (0..255) | CT |
| 40 | Thermostat | Fan Speed Enumerated (0,1,2) | 1 Byte | 5.100 fan stage (0..255) | CT |
| 40 | Thermostat | Fan Speed Enumerated (0,1,2,3,4) | 1 Byte | 5.100 fan stage (0..255) | CT |
| 40 | Thermostat | Fan Speed Enumerated (0,1,2,3,4,5) | 1 Byte | 5.100 fan stage (0..255) | CT |
| 41 | Thermostat | Fan Speed Enumerated Status (1,2,3) | 1 Byte | 5.100 fan stage (0..255) | CWTU |
| 41 | Thermostat | Fan Speed Enumerated Status (1) | 1 Byte | 5.100 fan stage (0..255) | CWTU |
| 41 | Thermostat | Fan Speed Enumerated Status (1,2) | 1 Byte | 5.100 fan stage (0..255) | CWTU |
| 41 | Thermostat | Fan Speed Enumerated Status (1,2,3,4) | 1 Byte | 5.100 fan stage (0..255) | CWTU |
| 41 | Thermostat | Fan Speed Enumerated Status (1,2,3,4,5) | 1 Byte | 5.100 fan stage (0..255) | CWTU |
| 41 | Thermostat | Fan Speed Enumerated Status (0,1,2,3) | 1 Byte | 5.100 fan stage (0..255) | CWTU |
| 41 | Thermostat | Fan Speed Enumerated Status (0,1) | 1 Byte | 5.100 fan stage (0..255) | CWTU |
| 41 | Thermostat | Fan Speed Enumerated Status (0,1,2) | 1 Byte | 5.100 fan stage (0..255) | CWTU |
| 41 | Thermostat | Fan Speed Enumerated Status (0,1,2,3,4) | 1 Byte | 5.100 fan stage (0..255) | CWTU |
| 41 | Thermostat | Fan Speed Enumerated Status (0,1,2,3,4,5) | 1 Byte | 5.100 fan stage (0..255) | CWTU |
| 42 | Thermostat | Fan Speed Scaling (33,67,100)% | 1 Byte | 5.1 percentage (0..100%) | CT |
| 42 | Thermostat | Fan Speed Scaling (100)% | 1 Byte | 5.1 percentage (0..100%) | CT |
| 42 | Thermostat | Fan Speed Scaling (50,100)% | 1 Byte | 5.1 percentage (0..100%) | CT |
| 42 | Thermostat | Fan Speed Scaling (25,50,75,100)% | 1 Byte | 5.1 percentage (0..100%) | CT |
| 42 | Thermostat | Fan Speed Scaling (20,40,60,80,100)% | 1 Byte | 5.1 percentage (0..100%) | CT |
| 42 | Thermostat | Fan Speed Scaling (0,33,67,100)% | 1 Byte | 5.1 percentage (0..100%) | CT |
| 42 | Thermostat | Fan Speed Scaling (0,100)% | 1 Byte | 5.1 percentage (0..100%) | CT |
| 42 | Thermostat | Fan Speed Scaling (0,50,100)% | 1 Byte | 5.1 percentage (0..100%) | CT |
| 42 | Thermostat | Fan Speed Scaling (0,25,50,75,100)% | 1 Byte | 5.1 percentage (0..100%) | CT |
| 42 | Thermostat | Fan Speed Scaling (0,20,40,60,80,100)% | 1 Byte | 5.1 percentage (0..100%) | CT |
| 43 | Thermostat | Fan Speed Scaling Status (33,67,100)% | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 43 | Thermostat | Fan Speed Scaling Status (100)% | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 43 | Thermostat | Fan Speed Scaling Status (50,100)% | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 43 | Thermostat | Fan Speed Scaling Status (25,50,75,100)% | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 43 | Thermostat | Fan Speed Scaling Status (20,40,60,80,100)% | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 43 | Thermostat | Fan Speed Scaling Status (0,33,67,100)% | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 43 | Thermostat | Fan Speed Scaling Status (0,100)% | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 43 | Thermostat | Fan Speed Scaling Status (0,50,100)% | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 43 | Thermostat | Fan Speed Scaling Status (0,25,50,75,100)% | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 43 | Thermostat | Fan Speed Scaling Status (0,20,40,60,80,100)% | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 44 | Thermostat | Fan 1 | 1 Bit | 1.11 state | CT |
| 45 | Thermostat | Fan 1 Status | 1 Bit | 1.11 state | CWTU |
| 46 | Thermostat | Fan 2 | 1 Bit | 1.11 state | CT |
| 47 | Thermostat | Fan 2 Status | 1 Bit | 1.11 state | CWTU |
| 48 | Thermostat | Fan 3 | 1 Bit | 1.11 state | CT |
| 49 | Thermostat | Fan 3 Status | 1 Bit | 1.11 state | CWTU |
| 50 | Thermostat | Fan 4 | 1 Bit | 1.11 state | CT |
| 51 | Thermostat | Fan 4 Status | 1 Bit | 1.11 state | CWTU |
| 52 | Thermostat | Fan 5 | 1 Bit | 1.11 state | CT |
| 53 | Thermostat | Fan 5 Status | 1 Bit | 1.11 state | CWTU |
| 54 | Thermostat | Fan Auto/Manual (1-Auto) | 1 Bit | 1.3 enable | CT |
| 54 | Thermostat | Fan Auto/Manual (0-Auto) | 1 Bit | 1.3 enable | CT |
| 55 | Thermostat | Fan Auto/Manual Status (1-Auto) | 1 Bit | 1.3 enable | CWTU |
| 55 | Thermostat | Fan Auto/Manual Status (0-Auto) | 1 Bit | 1.3 enable | CWTU |
| 56 | Thermostat | Fan Off (1-Off) | 1 Bit | 1.11 state | CT |
| 56 | Thermostat | Fan Off (0-Off) | 1 Bit | 1.11 state | CT |
| 57 | Thermostat | Fan Off Status (1-Off) | 1 Bit | 1.11 state | CWTU |
| 57 | Thermostat | Fan Off Status (0-Off) | 1 Bit | 1.11 state | CWTU |
| 58 | Thermostat | Thermostat On/Off | 1 Bit | 1.1 switch | CWU |
| 59 | Thermostat | Thermostat On/Off Status | 1 Bit | 1.1 switch | CRT |
| 60 | Thermostat | Window Contact (1-Open, 0-Close) | 1 Bit | 1.19 window/door | CWTU |
| 60 | Thermostat | Window Contact (0-Open, 1-Close) | 1 Bit | 1.9 open/close | CWTU |
| 61 | Air Conditioner | Control On/Off | 1 Bit | 1.1 switch | CT |
| 62 | Air Conditioner | Control On/Off Status | 1 Bit | 1.1 switch | CWTU |
| 63 | Air Conditioner | Setpoint Control | 2 Bytes | 9.1 temperature (°C) | CT |
| 64 | Air Conditioner | Setpoint Status | 2 Bytes | 9.1 temperature (°C) | CWTU |
| 65 | Air Conditioner | Setpoint (-/+) | 1 Bit | 1.7 step | CWTU |
| 66 | Air Conditioner | Control Mode Heat/Cool (1-Heat, 0-Cool) | 1 Bit | 1.100 cooling/heating | CT |
| 67 | Air Conditioner | Control Mode Heat/Cool Status (1-Heat, 0-Cool) | 1 Bit | 1.100 cooling/heating | CWTU |
| 68 | Air Conditioner | Control Modes (0-Auto, 1-Heat, 3-Cool, 9-Fan, 14-Dry) | 1 Byte | 20.105 HVAC control mode | CT |
| 69 | Air Conditioner | Control Modes Status (0-Auto, 1-Heat, 3-Cool, 9-Fan, 14-Dry) | 1 Byte | 20.105 HVAC control mode | CWTU |
| 70 | Air Conditioner | Auto Mode | 1 Bit | 1.11 state | CT |
| 71 | Air Conditioner | Auto Mode Status | 1 Bit | 1.11 state | CWTU |
| 72 | Air Conditioner | Heat Mode | 1 Bit | 1.11 state | CT |
| 73 | Air Conditioner | Heat Mode Status | 1 Bit | 1.11 state | CWTU |
| 74 | Air Conditioner | Cool Mode | 1 Bit | 1.11 state | CT |
| 75 | Air Conditioner | Cool Mode Status | 1 Bit | 1.11 state | CWTU |
| 76 | Air Conditioner | Fan Mode | 1 Bit | 1.11 state | CT |
| 77 | Air Conditioner | Fan Mode Status | 1 Bit | 1.11 state | CWTU |
| 78 | Air Conditioner | Dry Mode | 1 Bit | 1.11 state | CT |
| 79 | Air Conditioner | Dry Mode Status | 1 Bit | 1.11 state | CWTU |
| 80 | Air Conditioner | Fan Speed Enumerated (1,2,3) | 1 Byte | 5.100 fan stage (0..255) | CT |
| 80 | Air Conditioner | Fan Speed Enumerated (1) | 1 Byte | 5.100 fan stage (0..255) | CT |
| 80 | Air Conditioner | Fan Speed Enumerated (1,2) | 1 Byte | 5.100 fan stage (0..255) | CT |
| 80 | Air Conditioner | Fan Speed Enumerated (1,2,3,4) | 1 Byte | 5.100 fan stage (0..255) | CT |
| 80 | Air Conditioner | Fan Speed Enumerated (1,2,3,4,5) | 1 Byte | 5.100 fan stage (0..255) | CT |
| 80 | Air Conditioner | Fan Speed Enumerated (0,1,2,3) | 1 Byte | 5.100 fan stage (0..255) | CT |
| 80 | Air Conditioner | Fan Speed Enumerated (0,1) | 1 Byte | 5.100 fan stage (0..255) | CT |
| 80 | Air Conditioner | Fan Speed Enumerated (0,1,2) | 1 Byte | 5.100 fan stage (0..255) | CT |
| 80 | Air Conditioner | Fan Speed Enumerated (0,1,2,3,4) | 1 Byte | 5.100 fan stage (0..255) | CT |
| 80 | Air Conditioner | Fan Speed Enumerated (0,1,2,3,4,5) | 1 Byte | 5.100 fan stage (0..255) | CT |
| 81 | Air Conditioner | Fan Speed Enumerated Status (1,2,3) | 1 Byte | 5.100 fan stage (0..255) | CWTU |
| 81 | Air Conditioner | Fan Speed Enumerated Status (1) | 1 Byte | 5.100 fan stage (0..255) | CWTU |
| 81 | Air Conditioner | Fan Speed Enumerated Status (1,2) | 1 Byte | 5.100 fan stage (0..255) | CWTU |
| 81 | Air Conditioner | Fan Speed Enumerated Status (1,2,3,4) | 1 Byte | 5.100 fan stage (0..255) | CWTU |
| 81 | Air Conditioner | Fan Speed Enumerated Status (1,2,3,4,5) | 1 Byte | 5.100 fan stage (0..255) | CWTU |
| 81 | Air Conditioner | Fan Speed Enumerated Status (0,1,2,3) | 1 Byte | 5.100 fan stage (0..255) | CWTU |
| 81 | Air Conditioner | Fan Speed Enumerated Status (0,1) | 1 Byte | 5.100 fan stage (0..255) | CWTU |
| 81 | Air Conditioner | Fan Speed Enumerated Status (0,1,2) | 1 Byte | 5.100 fan stage (0..255) | CWTU |
| 81 | Air Conditioner | Fan Speed Enumerated Status (0,1,2,3,4) | 1 Byte | 5.100 fan stage (0..255) | CWTU |
| 81 | Air Conditioner | Fan Speed Enumerated Status (0,1,2,3,4,5) | 1 Byte | 5.100 fan stage (0..255) | CWTU |
| 82 | Air Conditioner | Fan Speed Scaling (33,67,100)% | 1 Byte | 5.1 percentage (0..100%) | CT |
| 82 | Air Conditioner | Fan Speed Scaling (100)% | 1 Byte | 5.1 percentage (0..100%) | CT |
| 82 | Air Conditioner | Fan Speed Scaling (50,100)% | 1 Byte | 5.1 percentage (0..100%) | CT |
| 82 | Air Conditioner | Fan Speed Scaling (25,50,75,100)% | 1 Byte | 5.1 percentage (0..100%) | CT |
| 82 | Air Conditioner | Fan Speed Scaling (20,40,60,80,100)% | 1 Byte | 5.1 percentage (0..100%) | CT |
| 82 | Air Conditioner | Fan Speed Scaling (0,33,67,100)% | 1 Byte | 5.1 percentage (0..100%) | CT |
| 82 | Air Conditioner | Fan Speed Scaling (0,100)% | 1 Byte | 5.1 percentage (0..100%) | CT |
| 82 | Air Conditioner | Fan Speed Scaling (0,50,100)% | 1 Byte | 5.1 percentage (0..100%) | CT |
| 82 | Air Conditioner | Fan Speed Scaling (0,25,50,75,100)% | 1 Byte | 5.1 percentage (0..100%) | CT |
| 82 | Air Conditioner | Fan Speed Scaling (0,20,40,60,80,100)% | 1 Byte | 5.1 percentage (0..100%) | CT |
| 83 | Air Conditioner | Fan Speed Scaling Status (33,67,100)% | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 83 | Air Conditioner | Fan Speed Scaling Status (100)% | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 83 | Air Conditioner | Fan Speed Scaling Status (50,100)% | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 83 | Air Conditioner | Fan Speed Scaling Status (25,50,75,100)% | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 83 | Air Conditioner | Fan Speed Scaling Status (20,40,60,80,100)% | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 83 | Air Conditioner | Fan Speed Scaling Status (0,33,67,100)% | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 83 | Air Conditioner | Fan Speed Scaling Status (0,100)% | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 83 | Air Conditioner | Fan Speed Scaling Status (0,50,100)% | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 83 | Air Conditioner | Fan Speed Scaling Status (0,25,50,75,100)% | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 83 | Air Conditioner | Fan Speed Scaling Status (0,20,40,60,80,100)% | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 84 | Air Conditioner | Fan 1 | 1 Bit | 1.11 state | CT |
| 85 | Air Conditioner | Fan 1 Status | 1 Bit | 1.11 state | CWTU |
| 86 | Air Conditioner | Fan 2 | 1 Bit | 1.11 state | CT |
| 87 | Air Conditioner | Fan 2 Status | 1 Bit | 1.11 state | CWTU |
| 88 | Air Conditioner | Fan 3 | 1 Bit | 1.11 state | CT |
| 89 | Air Conditioner | Fan 3 Status | 1 Bit | 1.11 state | CWTU |
| 90 | Air Conditioner | Fan 4 | 1 Bit | 1.11 state | CT |
| 91 | Air Conditioner | Fan 4 Status | 1 Bit | 1.11 state | CWTU |
| 92 | Air Conditioner | Fan 5 | 1 Bit | 1.11 state | CT |
| 93 | Air Conditioner | Fan 5 Status | 1 Bit | 1.11 state | CWTU |
| 94 | Air Conditioner | Fan Auto/Manual (1-Auto) | 1 Bit | 1.3 enable | CT |
| 94 | Air Conditioner | Fan Auto/Manual (0-Auto) | 1 Bit | 1.3 enable | CT |
| 95 | Air Conditioner | Fan Auto/Manual Status (1-Auto) | 1 Bit | 1.3 enable | CWTU |
| 95 | Air Conditioner | Fan Auto/Manual Status (0-Auto) | 1 Bit | 1.3 enable | CWTU |
| 96 | Air Conditioner | Vanes Up-Down (0-Swing Off, 1-Pos1, 2-Pos2, 3-Pos3, 4-Pos4, 5-Pos5, 6-Swing On) | 1 Byte | | CT |
| 97 | Air Conditioner | Vanes Up-Down Status (0-Swing Off, 1-Pos1, 2-Pos2, 3-Pos3, 4-Pos4, 5-Pos5, 6-Swing On) | 1 Byte | | CWTU |
| 98 | Air Conditioner | Swing Up/Down | 1 Bit | 1.11 state | CT |
| 99 | Air Conditioner | Swing Up/Down Status | 1 Bit | 1.11 state | CWTU |
| 100 | Air Conditioner | Vanes Left-Right (0-Swing Off, 1-Pos1, 2-Pos2, 3-Pos3, 4-Pos4, 5-Pos5, 6-Swing On) | 1 Byte | | CT |
| 101 | Air Conditioner | Vanes Left-Right Status (0-Swing Off, 1-Pos1, 2-Pos2, 3-Pos3, 4-Pos4, 5-Pos5, 6-Swing On) | 1 Byte | | CWTU |
| 102 | Air Conditioner | Swing Left/Right | 1 Bit | 1.11 state | CT |
| 103 | Air Conditioner | Swing Left/Right Status | 1 Bit | 1.11 state | CWTU |
| 104 | Air Conditioner | Error 1 Bit (1-Error, 0-No Error) | 1 Bit | 1.5 alarm | CWTU |
| 105 | Button 1 | Switch Status | 1 Bit | 1.1 switch | CWTU |
| 106 | Button 1 | Switch On/Off | 1 Bit | 1.1 switch | CT |
| 106 | Rocker | Switch On/Off | 1 Bit | 1.1 switch | CT |
| 107 | Button 1 | Switch Status | 1 Bit | 1.1 switch | CWTU |
| 108 | Button 1 | Switch On/Off | 1 Bit | 1.1 switch | CT |
| 108 | Rocker | Switch On/Off | 1 Bit | 1.1 switch | CT |
| 109 | Button 1 | Long Switch Status | 1 Bit | 1.1 switch | CWTU |
| 110 | Button 1 | Long Switch On/Off | 1 Bit | 1.1 switch | CT |
| 111 | Button 1 | LED | 1 Bit | 1.1 switch | CWTU |
| 111 | Rocker | LED | 1 Bit | 1.1 switch | CWTU |
| 112 | Button 1 | Jamming | 1 Bit | 1.3 enable | CRWU |
| 112 | Rocker | Jamming | 1 Bit | 1.3 enable | CRWU |
| 113 | Button 1 | Up/Down | 1 Bit | 1.8 up/down | CT |
| 113 | Rocker | Up/Down | 1 Bit | 1.8 up/down | CT |
| 114 | Button 1 | Step/Stop | 1 Bit | 1.2 boolean | CT |
| 114 | Rocker | Step/Stop | 1 Bit | 1.2 boolean | CT |
| 115 | Button 1 | Dimming | 4 Bit | 3.7 dimming control | CT |
| 115 | Rocker | Dimming | 4 Bit | 3.7 dimming control | CT |
| 116 | Button 1 | Execute/Store | 1 Byte | 18.1 scene control | CT |
| 116 | Button 1 | Execute | 1 Byte | 18.1 scene control | CT |
| 117 | Button 1 | Value (1 bit) | 1 Bit | 1.1 switch | CT |
| 117 | Rocker | Value (1 bit) | 1 Bit | 1.1 switch | CT |
| 118 | Button 1 | Value (1 byte) | 1 Byte | 5.10 counter pulses (0..255) | CT |
| 118 | Button 1 | Value (1 byte) | 1 Byte | 6.10 counter pulses (-128..127) | CT |
| 118 | Button 1 | Value (1 byte) | 1 Byte | 5.1 percentage (0..100%) | CT |
| 118 | Rocker | Value (1 byte) | 1 Byte | 5.1 percentage (0..100%) | CT |
| 118 | Rocker | Value (1 byte) | 1 Byte | 6.10 counter pulses (-128..127) | CT |
| 118 | Rocker | Value (1 byte) | 1 Byte | 5.10 counter pulses (0..255) | CT |
| 119 | Button 1 | Value (2 byte) | 2 Bytes | 7.1 pulses | CT |
| 119 | Button 1 | Value (2 byte) | 2 Bytes | 9.1 temperature (°C) | CT |
| 119 | Button 1 | Value (2 byte) | 2 Bytes | 8.1 pulses difference | CT |
| 119 | Rocker | Value (2 byte) | 2 Bytes | 7.1 pulses | CT |
| 119 | Rocker | Value (2 byte) | 2 Bytes | 9.1 temperature (°C) | CT |
| 119 | Rocker | Value (2 byte) | 2 Bytes | 8.1 pulses difference | CT |
| 120 | Button 1 | Long Value (1 bit) | 1 Bit | 1.1 switch | CT |
| 121 | Button 1 | Long Value (1 byte) | 1 Byte | 5.10 counter pulses (0..255) | CT |
| 121 | Button 1 | Long Value (1 byte) | 1 Byte | 6.10 counter pulses (-128..127) | CT |
| 121 | Button 1 | Long Value (1 byte) | 1 Byte | 5.1 percentage (0..100%) | CT |
| 122 | Button 1 | Long Value (2 byte) | 2 Bytes | 7.1 pulses | CT |
| 122 | Button 1 | Long Value (2 byte) | 2 Bytes | 9.1 temperature (°C) | CT |
| 122 | Button 1 | Long Value (2 byte) | 2 Bytes | 8.1 pulses difference | CT |
| 123 | Button 2 | Switch Status | 1 Bit | 1.1 switch | CWTU |
| 124 | Button 2 | Switch On/Off | 1 Bit | 1.1 switch | CT |
| 125 | Button 2 | Switch Status | 1 Bit | 1.1 switch | CWTU |
| 126 | Button 2 | Switch On/Off | 1 Bit | 1.1 switch | CT |
| 127 | Button 2 | Long Switch Status | 1 Bit | 1.1 switch | CWTU |
| 128 | Button 2 | Long Switch On/Off | 1 Bit | 1.1 switch | CT |
| 129 | Button 2 | LED | 1 Bit | 1.1 switch | CWTU |
| 130 | Button 2 | Jamming | 1 Bit | 1.3 enable | CRWU |
| 131 | Button 2 | Up/Down | 1 Bit | 1.8 up/down | CT |
| 132 | Button 2 | Step/Stop | 1 Bit | 1.2 boolean | CT |
| 133 | Button 2 | Dimming | 4 Bit | 3.7 dimming control | CT |
| 134 | Button 2 | Execute/Store | 1 Byte | 18.1 scene control | CT |
| 134 | Button 2 | Execute | 1 Byte | 18.1 scene control | CT |
| 135 | Button 2 | Value (1 bit) | 1 Bit | 1.1 switch | CT |
| 136 | Button 2 | Value (1 byte) | 1 Byte | 5.10 counter pulses (0..255) | CT |
| 136 | Button 2 | Value (1 byte) | 1 Byte | 6.10 counter pulses (-128..127) | CT |
| 136 | Button 2 | Value (1 byte) | 1 Byte | 5.1 percentage (0..100%) | CT |
| 137 | Button 2 | Value (2 byte) | 2 Bytes | 7.1 pulses | CT |
| 137 | Button 2 | Value (2 byte) | 2 Bytes | 9.1 temperature (°C) | CT |
| 137 | Button 2 | Value (2 byte) | 2 Bytes | 8.1 pulses difference | CT |
| 138 | Button 2 | Long Value (1 bit) | 1 Bit | 1.1 switch | CT |
| 139 | Button 2 | Long Value (1 byte) | 1 Byte | 5.10 counter pulses (0..255) | CT |
| 139 | Button 2 | Long Value (1 byte) | 1 Byte | 6.10 counter pulses (-128..127) | CT |
| 139 | Button 2 | Long Value (1 byte) | 1 Byte | 5.1 percentage (0..100%) | CT |
| 140 | Button 2 | Long Value (2 byte) | 2 Bytes | 7.1 pulses | CT |
| 140 | Button 2 | Long Value (2 byte) | 2 Bytes | 9.1 temperature (°C) | CT |
| 140 | Button 2 | Long Value (2 byte) | 2 Bytes | 8.1 pulses difference | CT |
| 141 | Scene | Call | 1 Byte | 18.1 scene control | CW |
| 142 | Logic 1 | Output (1 bit) | 1 Bit | 1.1 switch | CRT |
| 143 | Logic 1 | Output (1 Byte) | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 143 | Logic 1 | Output (1 Byte) | 1 Byte | 6.10 counter pulses (-128..127) | CRT |
| 143 | Logic 1 | Output (1 Byte) | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 144 | Logic 1 | Output (2 Bytes) | 2 Bytes | 7.1 pulses | CRT |
| 144 | Logic 1 | Output (2 Bytes) | 2 Bytes | 8.1 pulses difference | CRT |
| 144 | Logic 1 | Output (2 Bytes) | 2 Bytes | 9.1 temperature (°C) | CRT |
| 145 | Logic 1 | Input 1 | 1 Bit | 1.2 boolean | CWTU |
| 146 | Logic 1 | Input 2 | 1 Bit | 1.2 boolean | CWTU |
| 147 | Logic 1 | Input 3 | 1 Bit | 1.2 boolean | CWTU |
| 148 | Logic 1 | Input 4 | 1 Bit | 1.2 boolean | CWTU |
| 149 | Logic 2 | Output (1 bit) | 1 Bit | 1.1 switch | CRT |
| 150 | Logic 2 | Output (1 Byte) | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 150 | Logic 2 | Output (1 Byte) | 1 Byte | 6.10 counter pulses (-128..127) | CRT |
| 150 | Logic 2 | Output (1 Byte) | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 151 | Logic 2 | Output (2 Bytes) | 2 Bytes | 7.1 pulses | CRT |
| 151 | Logic 2 | Output (2 Bytes) | 2 Bytes | 8.1 pulses difference | CRT |
| 151 | Logic 2 | Output (2 Bytes) | 2 Bytes | 9.1 temperature (°C) | CRT |
| 152 | Logic 2 | Input 1 | 1 Bit | 1.2 boolean | CWTU |
| 153 | Logic 2 | Input 2 | 1 Bit | 1.2 boolean | CWTU |
| 154 | Logic 2 | Input 3 | 1 Bit | 1.2 boolean | CWTU |
| 155 | Logic 2 | Input 4 | 1 Bit | 1.2 boolean | CWTU |
| 156 | Logic 3 | Output (1 bit) | 1 Bit | 1.1 switch | CRT |
| 157 | Logic 3 | Output (1 Byte) | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 157 | Logic 3 | Output (1 Byte) | 1 Byte | 6.10 counter pulses (-128..127) | CRT |
| 157 | Logic 3 | Output (1 Byte) | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 158 | Logic 3 | Output (2 Bytes) | 2 Bytes | 7.1 pulses | CRT |
| 158 | Logic 3 | Output (2 Bytes) | 2 Bytes | 8.1 pulses difference | CRT |
| 158 | Logic 3 | Output (2 Bytes) | 2 Bytes | 9.1 temperature (°C) | CRT |
| 159 | Logic 3 | Input 1 | 1 Bit | 1.2 boolean | CWTU |
| 160 | Logic 3 | Input 2 | 1 Bit | 1.2 boolean | CWTU |
| 161 | Logic 3 | Input 3 | 1 Bit | 1.2 boolean | CWTU |
| 162 | Logic 3 | Input 4 | 1 Bit | 1.2 boolean | CWTU |
| 163 | Logic 4 | Output (1 bit) | 1 Bit | 1.1 switch | CRT |
| 164 | Logic 4 | Output (1 Byte) | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 164 | Logic 4 | Output (1 Byte) | 1 Byte | 6.10 counter pulses (-128..127) | CRT |
| 164 | Logic 4 | Output (1 Byte) | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 165 | Logic 4 | Output (2 Bytes) | 2 Bytes | 7.1 pulses | CRT |
| 165 | Logic 4 | Output (2 Bytes) | 2 Bytes | 8.1 pulses difference | CRT |
| 165 | Logic 4 | Output (2 Bytes) | 2 Bytes | 9.1 temperature (°C) | CRT |
| 166 | Logic 4 | Input 1 | 1 Bit | 1.2 boolean | CWTU |
| 167 | Logic 4 | Input 2 | 1 Bit | 1.2 boolean | CWTU |
| 168 | Logic 4 | Input 3 | 1 Bit | 1.2 boolean | CWTU |
| 169 | Logic 4 | Input 4 | 1 Bit | 1.2 boolean | CWTU |