KNX Database
Core Smart Home 0000200003 Daikin VRV&SKY Systems Gateway

Daikin VRV&SKY Systems Gateway 0000200003

Core Smart Home · Order number 0000200003 · AC Gateways

Daikin VRV&SKY Systems Gateway

Download .knxprod Core_DK_AC_INT_V3 0.3 · 112 KB

Product

ManufacturerCore Smart Home
Product nameDaikin VRV&SKY Systems Gateway
Order number0000200003
Product textCR-CG-DK-KNX-01
HardwareCore_DK_AC_INT_V3
MediumTwisted Pair
Bus current (mA)10
Rail mountedNo
RegistrationCertified · 2023-03-16
Languagesen-US
Catalog entryM-0228_H-0228FF200001-3_HP-07D0-03-27D5_CI-0000200003-1
Fingerprint27D5
SHA-256eabbe5ef0de6f8ab4e7c96b37ed833df36e16acc34d280dfaf41fb0c9b0a985a
First seen2026-11-25
Markets59 markets

Application program: Core_DK_AC_INT_V3 0.3

Application number$07D0
Version0.3
Mask versionMV-07B0 (System B)
KNX Data SecureNo
Minimum ETS version5.0
Parameters25
Group objects52
Group objects (52)
NoNameFunctionSizeDPTFlags
1Control_On/Off [DPT_1.001 - 1bit]0-Off;1-On1 Bit1.1 switchCRWU
2Status_On/Off [DPT_1.001 - 1bit]0-Off;1-On1 Bit1.1 switchCRT
3Control_Setpoint_Temperature [DPT_9.001 - 2byte]16°C to 32°C2 Bytes9.1 temperature (°C)CRWU
4Status_Setpoint_Temperature [DPT_9.001 - 2byte]16°C to 32°C2 Bytes9.1 temperature (°C)CRT
5Control_Mode [DPT_20.105 -1byte]0-Auto;1-Heat;3-Cool;9-Fan;14-Dry1 Byte20.105 HVAC control modeCRWU
6Status_Mode [DPT_20.105 -1byte]0-Auto;1-Heat;3-Cool;9-Fan;14-Dry1 Byte20.105 HVAC control modeCRT
7Control_Fan_Speed / 2 Speeds [DPT_5.010 - 1byte]Speed Values;1,21 Byte5.100 fan stage (0..255)CRWU
7Control_Fan_Speed / 3 Speeds [DPT_5.010 - 1byte]Speed Values;1,2,31 Byte5.100 fan stage (0..255)CRWU
7Control_Fan_Speed / 2 Speeds [DPT_5.001 -1byte]Threshold:75%1 Byte5.1 percentage (0..100%)CRWU
7Control_Fan_Speed / 3 Speeds [DPT_5.001 -1byte]Threshold:50%,83%1 Byte5.1 percentage (0..100%)CRWU
7Control_Fan_Speed / 2 Speeds [DPT_5.010 - 1byte]Speed Values;0,1,21 Byte5.100 fan stage (0..255)CRWU
7Control_Fan_Speed / 3 Speeds [DPT_5.010 - 1byte]Speed Values;0,1,2,31 Byte5.100 fan stage (0..255)CRWU
7Control_Fan_Speed / 2 Speeds [DPT_5.001 -1byte]0-Auto; Threshold:75%1 Byte5.1 percentage (0..100%)CRWU
7Control_Fan_Speed / 3 Speeds [DPT_5.001 -1byte]0-Auto; Threshold:50%,83%1 Byte5.1 percentage (0..100%)CRWU
8Status_Fan_Speed / 2 Speeds [DPT_5.010 - 1byte]Speed Values;1,21 Byte5.100 fan stage (0..255)CRT
8Status_Fan_Speed / 3 Speeds [DPT_5.010 - 1byte]Speed Values;1,2,31 Byte5.100 fan stage (0..255)CRT
8Status_Fan_Speed / 2 Speeds [DPT_5.001 -1byte]50%,100%1 Byte5.1 percentage (0..100%)CRT
8Status_Fan_Speed / 3 Speeds [DPT_5.001 -1byte]33%,67%,100%1 Byte5.1 percentage (0..100%)CRT
8Status_Fan_Speed / 2 Speeds [DPT_5.010 - 1byte]Speed Values;0,1,21 Byte5.100 fan stage (0..255)CRT
8Status_Fan_Speed / 3 Speeds [DPT_5.010 - 1byte]Speed Values;0,1,2,31 Byte5.100 fan stage (0..255)CRT
8Status_Fan_Speed / 2 Speeds [DPT_5.001 -1byte]0-Auto; 50%,100%1 Byte5.1 percentage (0..100%)CRT
8Status_Fan_Speed / 3 Speeds [DPT_5.001 -1byte]0-Auto; 33%,67%,100%1 Byte5.1 percentage (0..100%)CRT
9Control_Vanes Up-Down [DPT_5.010 - 1byte]1-Pos1;2-Pos2;3-Pos3;4-Pos4;5-Pos5;6-Swng1 Byte5.10 counter pulses (0..255)CRWU
10Status_Vanes Up-Down [DPT_5.010 - 1byte]1-Pos1;2-Pos2;3-Pos3;4-Pos4;5-Pos5;6-Swng1 Byte5.10 counter pulses (0..255)CRT
11Control_AC_Return_Temp [DPT_9.001 - 2byte]°C value in EIS5 format2 Bytes9.1 temperature (°C)CRWU
12Status_AC_Return_Temp [DPT_9.001 - 2byte]°C value in EIS5 format2 Bytes9.1 temperature (°C)CRT
13Status_Error_Code [2byte]0-No Error / Any other see man.2 BytesCRT
14Control_Mode_Cool/Heat [DPT_1.100 - 1bit]0-Cool;1-Heat1 Bit1.100 cooling/heatingCRWU
15Status_Mode_Cool/Heat [DPT_1.100 - 1bit]0-Cool;1-Heat1 Bit1.100 cooling/heatingCRT
16Status_Error_Code [1bit]0-No Error1 Bit1.5 alarmCRT
17Input 1 [DPT_1.001 - 1bit]0-Off;1-On1 Bit1.1 switchCRT
18Input 2 [DPT_1.001 - 1bit]0-Off;1-On1 Bit1.1 switchCRT
19Control_Mode_Auto [DPT_1.002 - 1bit]1-Set AUTO mode1 Bit1.2 booleanCRWU
20Status_Mode_Auto [DPT_1.002 - 1bit]1-AUTO mode is active1 Bit1.2 booleanCRT
21Control_Mode_Heat [DPT_1.002 - 1bit]1-Set HEAT mode1 Bit1.2 booleanCRWU
22Status_Mode_Heat [DPT_1.002 - 1bit]1-HEAT mode is active1 Bit1.2 booleanCRT
23Control_Mode_Cool [DPT_1.002 - 1bit]1-Set COOL mode1 Bit1.2 booleanCRWU
24Status_Mode_Cool [DPT_1.002 - 1bit]1-COOL mode is active1 Bit1.2 booleanCRT
25Control_Mode_Fan [DPT_1.002 - 1bit]1-Set FAN mode1 Bit1.2 booleanCRWU
26Status_Mode_Fan [DPT_1.002 - 1bit]1-FAN mode is active1 Bit1.2 booleanCRT
27Control_Mode_Dry [DPT_1.002 - 1bit]1-Set DRY mode1 Bit1.2 booleanCRWU
28Status_Mode_Dry [DPT_1.002 - 1bit]1-DRY mode is active1 Bit1.2 booleanCRT
29Control_Fan_Speed_Manual/Auto [DPT_1.002 - 1bit]0-Manual;1-Auto1 Bit1.2 booleanCRWU
30Status_Fan_Speed_Manual/Auto [DPT_1.002 - 1bit]0-Manual;1-Auto1 Bit1.2 booleanCRT
31Control_Fan_Speed_1 [DPT_1.002 - 1bit]1-Set Fan Speed 11 Bit1.2 booleanCRWU
32Status_Fan_Speed_1 [DPT_1.002 - 1bit]1-Fan Speed 11 Bit1.2 booleanCRT
33Control_Fan_Speed_2 [DPT_1.002 - 1bit]1-Set Fan Speed 21 Bit1.2 booleanCRWU
34Status_Fan_Speed_2 [DPT_1.002 - 1bit]1-Fan Speed 21 Bit1.2 booleanCRT
35Control_Fan_Speed_3 [DPT_1.002 - 1bit]1-Set Fan Speed 31 Bit1.2 booleanCRWU
36Status_Fan_Speed_3 [DPT_1.002 - 1bit]1-Fan Speed 31 Bit1.2 booleanCRT
37Control_Fan_Speed +/- [DPT_1.008 - 1bit]0-Up;1-Down1 Bit1.8 up/downCRWU
37Control_Fan_Speed -/+ [DPT_1.007 - 1bit]0-Decrease;1-Increase1 Bit1.7 stepCRWU
Parameters (25)
ParameterTypeDefault
Available Fan Speeds in Indoor UnitunsignedInt 2…33
Alive Beacon Timer(ms)unsignedInt 500…100003000
Upper Limit(°C)unsignedInt 16…3232
Lower Limit(°C)unsignedInt 16…3216
Enable Object "Error Code [2Byte]"listNo
Enable Object "Error Code [1bit]"listNo
Enable Mode Cool/Heat objects (Control&Status)listNo
Enable Use of Digital Input 1listNo
Enable Use of Digital Input 2listNo
Digital Input 1 Contact TypelistNO
Digital Input 2 Contact TypelistNO
Fan Speed DPT Object TypelistEnumerated [DPT 5.010]
Fan is accessible in Indoor unitlistYes
Enable Fan Speed Manual/Auto objects (Control&Status)listNo
Enable use of Bit-type Fan Speed objects (Control&Status)listNo
Enable Mode Bit-type objects (Control&Status)listNo
Ambient temperature is provided from KNXlistNo
Alive BeaconlistNo
Enable Up/Down Vanes ControllistNo
Core_DKACInt is master in P1/P2 bus(If set to "yes", WRC must be SLAVE)listYes
Enable limits on Setpoint Temp.listNo
Enable +/- objects for Fan SpeedlistNo
Fan Speed +/- Onject DPT TypelistUp/Down [DPT 1.008]
Indoor Unit has AUTO Fan SpeedlistNo
For more Information, User Manual & Latest Database Entrytextwww.core.com.tr

Version history

ApplicationApp noFingerprintFirst seenSizeFile
Core_DK_AC_INT_V3 0.3 latest$07D027D52026-11-25112 KBDownload

About this file

This is the official ETS product database for the Core Smart Home Daikin VRV&SKY Systems Gateway (0000200003), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.

More from Core Smart Home

All Core Smart Home products