KNX Database
Core Smart Home 0000040001 LG VRF Gateway

LG VRF Gateway 0000040001

Core Smart Home · Order number 0000040001 · AC Gateways

LG VRF Gateway

Download .knxprod Core_LG_AC_INT_V1 1.1 · 114 KB

Product

ManufacturerCore Smart Home
Product nameLG VRF Gateway
Order number0000040001
Product textCR-CG-LG-KNX-01
HardwareCore_LG_AC_INT_V1
MediumTwisted Pair
Bus current (mA)10
Rail mountedNo
RegistrationCertified · 2023-05-08
Languagesen-US
Catalog entryM-0228_H-0228FF400001-1_HP-2010-11-A743_CI-0000040001-1
FingerprintA743
SHA-256ae09654536d5eabb19bf399e18b8c0b6790183b75b6dc802dc46fae09c88019d
First seen2026-11-25
Markets59 markets

Application program: Core_LG_AC_INT_V1 1.1

Application number$2010
Version1.1
Mask versionMV-07B0 (System B)
KNX Data SecureNo
Minimum ETS version5.0
Parameters31
Group objects82
Group objects (82)
NoNameFunctionSizeDPTFlags
1Control_On/Off [DPT_1.001 - 1bit]0-Off; 1-On1 Bit1.1 switchCRWU
2Status_On/Off [DPT_1.001 - 1bit]0-Off; 1-On1 Bit1.1 switchCRT
3Control_Setpoint_Temperature [DPT_9.001 - 2byte](°C)2 Bytes9.1 temperature (°C)CRWU
4Status_Setpoint_Temperature [DPT_9.001 - 2byte](°C)2 Bytes9.1 temperature (°C)CRT
5Control_Mode [DPT_20.105 - 1byte]0-Auto; 1-Heat; 3-Cool; 9-Fan; 14-Dry1 Byte20.105 HVAC control modeCRWU
5Control_Mode [DPT_20.105 - 1byte]0-Auto; 1-Heat; 3-Cool; 14-Dry1 Byte20.105 HVAC control modeCRWU
6Status_Mode [DPT_20.105 - 1byte]0-Auto; 1-Heat; 3-Cool; 9-Fan; 14-Dry1 Byte20.105 HVAC control modeCRT
6Status_Mode [DPT_20.105 - 1byte]0-Auto; 1-Heat; 3-Cool; 14-Dry1 Byte20.105 HVAC control modeCRT
7Control_Fan_Speed / 3 Speeds [DPT_5.100 - 1byte]Speed Values: 1,2,31 Byte5.100 fan stage (0..255)CRWU
7Control_Fan_Speed / 4 Speeds [DPT_5.100 - 1byte]Speed Values: 1,2,3,41 Byte5.100 fan stage (0..255)CRWU
7Control_Fan_Speed / 5 Speeds [DPT_5.100 - 1byte]Speed Values: 1,2,3,4,51 Byte5.100 fan stage (0..255)CRWU
7Control_Fan_Speed / 3 Speeds [DPT_5.001 - 1byte]Threshold: 50%,83%1 Byte5.1 percentage (0..100%)CRWU
7Control_Fan_Speed / 4 Speeds [DPT_5.001 - 1byte]Threshold: 38%,63%,88%1 Byte5.1 percentage (0..100%)CRWU
7Control_Fan_Speed / 5 Speeds [DPT_5.001 - 1byte]Threshold: 30%,50%,70%,90%1 Byte5.1 percentage (0..100%)CRWU
7Control_Fan_Speed / 3 Speeds [DPT_5.100 - 1byte]Speed Values: 0,1,2,31 Byte5.100 fan stage (0..255)CRWU
7Control_Fan_Speed / 4 Speeds [DPT_5.100 - 1byte]Speed Values: 0,1,2,3,41 Byte5.100 fan stage (0..255)CRWU
7Control_Fan_Speed / 5 Speeds [DPT_5.100 - 1byte]Speed Values: 0,1,2,3,4,51 Byte5.100 fan stage (0..255)CRWU
7Control_Fan_Speed / 3 Speeds [DPT_5.001 - 1byte]0-Auto; Threshold: 50%,83%1 Byte5.1 percentage (0..100%)CRWU
7Control_Fan_Speed / 4 Speeds [DPT_5.001 - 1byte]0-Auto; Threshold: 38%,63%,88%1 Byte5.1 percentage (0..100%)CRWU
7Control_Fan_Speed / 5 Speeds [DPT_5.001 - 1byte]0-Auto; Threshold: 30%,50%,70%,90%1 Byte5.1 percentage (0..100%)CRWU
8Status_Fan_Speed / 3 Speeds [DPT_5.100 - 1byte]Speed Values: 1,2,31 Byte5.100 fan stage (0..255)CRT
8Status_Fan_Speed / 4 Speeds [DPT_5.100 - 1byte]Speed Values: 1,2,3,41 Byte5.100 fan stage (0..255)CRT
8Status_Fan_Speed / 5 Speeds [DPT_5.100 - 1byte]Speed Values: 1,2,3,4,51 Byte5.100 fan stage (0..255)CRT
8Status_Fan_Speed / 3 Speeds [DPT_5.001 - 1byte]33%,67%,100%1 Byte5.1 percentage (0..100%)CRT
8Status_Fan_Speed / 4 Speeds [DPT_5.001 - 1byte]25%,50%,75%,100%1 Byte5.1 percentage (0..100%)CRT
8Status_Fan_Speed / 5 Speeds [DPT_5.001 - 1byte]20%,40%,60%,80%,100%1 Byte5.1 percentage (0..100%)CRT
8Status_Fan_Speed / 3 Speeds [DPT_5.100 - 1byte]Speed Values: 0,1,2,31 Byte5.100 fan stage (0..255)CRT
8Status_Fan_Speed / 4 Speeds [DPT_5.100 - 1byte]Speed Values: 0,1,2,3,41 Byte5.100 fan stage (0..255)CRT
8Status_Fan_Speed / 5 Speeds [DPT_5.100 - 1byte]Speed Values: 0,1,2,3,4,51 Byte5.100 fan stage (0..255)CRT
8Status_Fan_Speed / 3 Speeds [DPT_5.001 - 1byte]0-Auto; 33%,67%,100%1 Byte5.1 percentage (0..100%)CRT
8Status_Fan_Speed / 4 Speeds [DPT_5.001 - 1byte]0-Auto; 25%,50%,75%,100%1 Byte5.1 percentage (0..100%)CRT
8Status_Fan_Speed / 5 Speeds [DPT_5.001 - 1byte]0-Auto; 20%,40%,60%,80%,100%1 Byte5.1 percentage (0..100%)CRT
9Control_Vanes_Up-Down [DPT_5.010 - 1byte]1-Pos1; 2-Pos2; 3-Pos3; 4-Pos4; 5-Pos5; 6-Swing; 7-Swirl1 Byte5.10 counter pulses (0..255)CRWU
10Status_Vanes_Up-Down [DPT_5.010 - 1byte]1-Pos1; 2-Pos2; 3-Pos3; 4-Pos4; 5-Pos5; 6-Swing; 7-Swirl1 Byte5.10 counter pulses (0..255)CRT
11Control_AC_Return_Temp [DPT_9.001 - 2byte](°C)2 Bytes9.1 temperature (°C)CRWU
12Status_AC_Return_Temp [DPT_9.001 - 2byte](°C)2 Bytes9.1 temperature (°C)CRT
13Status_Error_Code [2byte]0-No Error / Any other see man.2 BytesCRT
14Control_Mode_Cool/Heat [DPT_1.100 - 1bit]0-Cool; 1-Heat1 Bit1.100 cooling/heatingCRWU
14Control_Mode_Heat/Cool [DPT_1.100 - 1bit]0-Heat; 1-Cool1 Bit1.100 cooling/heatingCRWU
15Status_Mode_Cool/Heat [DPT_1.100 - 1bit]0-Cool; 1-Heat1 Bit1.100 cooling/heatingCRT
15Status_Mode_Heat/Cool [DPT_1.100 - 1bit]0-Heat; 1-Cool1 Bit1.100 cooling/heatingCRT
16Input_1 [DPT_1.001 -1bit]0-Off; 1-On1 Bit1.1 switchCRT
17Input_2 [DPT_1.001 -1bit]0-Off; 1-On1 Bit1.1 switchCRT
18Control_Mode_Auto [DPT_1.002 - 1bit]1-Set AUTO mode1 Bit1.2 booleanCRWU
19Status_Mode_Auto [DPT_1.002 - 1bit]1-AUTO mode is active1 Bit1.2 booleanCRT
20Control_Mode_Heat [DPT_1.002 - 1bit]1-Set HEAT mode1 Bit1.2 booleanCRWU
21Status_Mode_Heat [DPT_1.002 - 1bit]1-HEAT mode is active1 Bit1.2 booleanCRT
22Control_Mode_Cool [DPT_1.002 - 1bit]1-Set COOL mode1 Bit1.2 booleanCRWU
23Status_Mode_Cool [DPT_1.002 - 1bit]1-COOL mode is active1 Bit1.2 booleanCRT
24Control_Mode_Fan [DPT_1.002 - 1bit]1-Set FAN mode1 Bit1.2 booleanCRWU
25Status_Mode_Fan [DPT_1.002 - 1bit]1-FAN mode is active1 Bit1.2 booleanCRT
26Control_Mode_Dry [DPT_1.002 - 1bit]1-Set DRY mode1 Bit1.2 booleanCRWU
27Status_Mode_Dry [DPT_1.002 - 1bit]1-DRY mode is active1 Bit1.2 booleanCRT
28Control_Fan_Speed_Manual/Auto [DPT_1.002 -1bit]0-Manual; 1-Auto1 Bit1.2 booleanCRWU
29Status_Fan_Speed_Manual/Auto [DPT_1.002 -1bit]0-Manual; 1-Auto1 Bit1.2 booleanCRT
30Control_Fan_Speed_1 [DPT_1.002 - 1bit]1-Set Fan Speed 11 Bit1.2 booleanCRWU
31Status_Fan_Speed_1 [DPT_1.002 - 1bit]1-Fan Speed 11 Bit1.2 booleanCRT
32Control_Fan_Speed_2 [DPT_1.002 - 1bit]1-Set Fan Speed 21 Bit1.2 booleanCRWU
33Status_Fan_Speed_2 [DPT_1.002 - 1bit]1-Fan Speed 21 Bit1.2 booleanCRT
34Control_Fan_Speed_3 [DPT_1.002 - 1bit]1-Set Fan Speed 31 Bit1.2 booleanCRWU
35Status_Fan_Speed_3 [DPT_1.002 - 1bit]1-Fan Speed 31 Bit1.2 booleanCRT
36Control_Fan_Speed_4 [DPT_1.002 - 1bit]1-Set Fan Speed 41 Bit1.2 booleanCRWU
37Status_Fan_Speed_4 [DPT_1.002 - 1bit]1-Fan Speed 41 Bit1.2 booleanCRT
38Control_Fan_Speed_5 [DPT_1.002 - 1bit]1-Set Fan Speed 51 Bit1.2 booleanCRWU
39Status_Fan_Speed_5 [DPT_1.002 - 1bit]1-Fan Speed 51 Bit1.2 booleanCRT
40Control_Fan_Speed -/+ [DPT_1.007 - 1bit]0-Decrease; 1-Increase1 Bit1.7 stepCRWU
40Control_Fan_Speed +/- [DPT_1.008 - 1bit]0-Up; 1-Down1 Bit1.8 up/downCRWU
41Error_Code/Alarm [DPT_1.005 - 1bit]0-No Error1 Bit1.5 alarmCRT
42Control_Up/Down_Vane_Pos_1 [DPT 1.002 - 1bit]1- Set Up/Down Vane Pos 11 Bit1.2 booleanCRWU
43Status_Up/Down_Vane_Pos_1 [DPT 1.002 - 1bit]1- Up/Down Vane Pos 11 Bit1.2 booleanCRT
44Control_Up/Down_Vane_Pos_2 [DPT 1.002 - 1bit]1- Set Up/Down Vane Pos 21 Bit1.2 booleanCRWU
45Status_Up/Down_Vane_Pos_2 [DPT 1.002 - 1bit]1- Up/Down Vane Pos 21 Bit1.2 booleanCRT
46Control_Up/Down_Vane_Pos_3 [DPT 1.002 - 1bit]1- Set Up/Down Vane Pos 31 Bit1.2 booleanCRWU
47Status_Up/Down_Vane_Pos_3 [DPT 1.002 - 1bit]1- Up/Down Vane Pos 31 Bit1.2 booleanCRT
48Control_Up/Down_Vane_Pos_4 [DPT 1.002 - 1bit]1- Set Up/Down Vane Pos 41 Bit1.2 booleanCRWU
49Status_Up/Down_Vane_Pos_4 [DPT 1.002 - 1bit]1- Up/Down Vane Pos 41 Bit1.2 booleanCRT
50Control_Up/Down_Vane_Pos_5 [DPT 1.002 - 1bit]1- Set Up/Down Vane Pos 51 Bit1.2 booleanCRWU
51Status_Up/Down_Vane_Pos_5 [DPT 1.002 - 1bit]1- Up/Down Vane Pos 51 Bit1.2 booleanCRT
52Control_Up/Down_Vane Swing [DPT 1.002 - 1bit]1- Set Up/Down Vane Swing1 Bit1.2 booleanCRWU
53Status_Up/Down_Vane Swing [DPT 1.002 - 1bit]1- Up/Down Vane Swing1 Bit1.2 booleanCRT
54Control_Up/Down_Vane_Swirl [DPT 1.002 - 1bit]1- Set Up/Down Vane Swirl1 Bit1.2 booleanCRWU
55Status_Up/Down_Vane_Swirl [DPT 1.002 - 1bit]1- Up/Down Vane Swirl1 Bit1.2 booleanCRT
Parameters (31)
ParameterTypeDefault
Alive BeaconlistNo
Alive Beacon Timer(ms)unsignedInt 500…100003000
Digital Input 1 Contact TypelistNO
Digital Input 2 Contact TypelistNO
Enable Use of Digital Input 1listNo
Enable Use of Digital Input 2listNo
Enable Object "Error Code [1bit]"listNo
Enable Object "Error Code [2Byte]"listNo
Fan Speed DPT Object TypelistEnumerated
Available Fan Speeds in Indoor UnitunsignedInt 3…55
Enable use of Bit-type Fan Speed objects (Control&Status)listNo
Indoor Unit has Auto Fan Speed?listYes
Enable Fan Speed Manual/Auto objects (Control&Status)listNo
Fan is Accessible in Indoor UnitlistYes
Fan Speed +/- Object DPT TypelistUp/Down
Enable +/- objects for Fan SpeedlistNo
Core_LG_AC_Int is configured as Master?listYes
Enable Mode Cool/Heat objects (Control&Status)listNo
Mode Heat/Cool Object ReverselistNo
Enable Mode Bit-type objects (Control&Status)listNo
Indoor Unit has Fan mode?listYes
Master of Mode EnablelistNo
Ambient temperature is provided from KNXlistNo
Enable limits on Setpoint Temp.listNo
Lower Limit(°C)unsignedInt 16…2916
Setpoint Temp. Scalelist1°C
Upper limit(°C)unsignedInt 17…3030
Enable Up/Down Vane Objects (Control&Status)listNo
For more Information, User Manual & Latest Database Entrytextwww.core.com.tr
Enable Up/Down Vane Bit-type objects (Control&Status)listNo
Com. Protocol TypelistNew

Version history

ApplicationApp noFingerprintFirst seenSizeFile
Core_LG_AC_INT_V1 1.1 latest$2010A7432026-11-25114 KBDownload

About this file

This is the official ETS product database for the Core Smart Home LG VRF Gateway (0000040001), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.

More from Core Smart Home

All Core Smart Home products