VAA/A6.24.2 Floor heating-Controller,6-fold 2CDG 120 061 R0011
ABB AG - STOTZ-KONTAKT · Order number 2CDG 120 061 R0011 · Heating, Ventilation and Air Conditioning › Valve Drive Actuators
Floor heating-Controller, 6-fold/1.0a
Download .knxprod Floor heating-Controller, 6-fold/1.0a 1.0 · 112 KB
Product
| Manufacturer | ABB AG - STOTZ-KONTAKT |
|---|---|
| Product name | VAA/A6.24.2 Floor heating-Controller,6-fold |
| Order number | 2CDG 120 061 R0011 |
| Hardware | HMT 6 S |
| Medium | Twisted Pair |
| Bus current (mA) | 7.5 |
| Rail mounted | Yes |
| Width (mm) | 290 |
| Registration | Registered · 2018-09-05 |
| Languages | en-US, de-DE |
| Catalog entry | M-0002_H-4900373-1-O0048_HP-490A-10-33AA-O0048_CI-2CDG.20120.20061.20R0011-1 |
| Fingerprint | 33AA |
| SHA-256 | 68a24496ff72175996af90c264634c96093867be503bd2cc7155b2c032f9d427 |
| First seen | 2026-11-25 |
| Markets | 59 markets |
Application program: Floor heating-Controller, 6-fold/1.0a 1.0
| Application number | $490A |
|---|---|
| Version | 1.0 |
| Mask version | MV-07B0 (System B) |
| KNX Data Secure | No |
| Minimum ETS version | 4.0 |
| Parameters | 418 |
| Group objects | 129 |
Group objects (129)
| No | Name | Function | Size | DPT | Flags |
|---|---|---|---|---|---|
| 1 | Channel H1 | Base setpoint value | 2 Bytes | 9.1 temperature (°C) | CRW |
| 1 | Channel H1 | Switching actuating value | 1 Bit | 1.1 switch | CRWU |
| 1 | Channel H1 | Continuous actuating value | 1 Byte | 5.1 percentage (0..100%) | CRWU |
| 2 | Channel H1 | Manual set point offset | 2 Bytes | 9.2 temperature difference (K) | CRW |
| 3 | Channel H1 | Actual value | 2 Bytes | 9.1 temperature (°C) | CRWU |
| 4 | Channel H1 | Operating mode preset | 1 Byte | 20.102 HVAC mode | CRW |
| 4 | Channel H1 | Current actuating value | 1 Byte | 5.1 percentage (0..100%) | CRTU |
| 5 | Channel H1 | Presence | 1 Bit | 1.18 occupancy | CRW |
| 6 | Channel H1 | Window position | 1 Bit | 1.19 window/door | CRW |
| 7 | Channel H1 | Current operating mode | 1 Byte | 20.102 HVAC mode | CRT |
| 8 | Channel H1 | Heating actuating value | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 8 | Channel H1 | Heat & cool actuating values | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 9 | Channel H1 | Cooling actuating value | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 10 | Channel H1 | Heating = 0, Cooling = 1 | 1 Bit | 1.1 switch | CRWU |
| 10 | Channel H1 | Heating = 1, Cooling = 0 | 1 Bit | 1.100 heating/cooling | CRWU |
| 11 | Channel H1 | Current setpoint value | 2 Bytes | 9.1 temperature (°C) | CRWT |
| 12 | Channel H1 | Report actuating value failure | 1 Bit | 1.5 alarm | CRTU |
| 12 | Channel H1 | Report actual value failure | 1 Bit | 1.5 alarm | CRTU |
| 13 | Channel H1 | Forced operation mode | 1 Bit | 1.3 enable | CRWU |
| 14 | Channel H1 | Overcurr./short circuit | 1 Bit | 1.5 alarm | CRTU |
| 21 | Channel H2 | Continuous actuating value | 1 Byte | 5.1 percentage (0..100%) | CRWU |
| 21 | Channel H2 | Switching actuating value | 1 Bit | 1.1 switch | CRWU |
| 21 | Channel H2 | Base setpoint | 2 Bytes | 9.1 temperature (°C) | CRW |
| 22 | Channel H2 | Manual setpoint offset | 2 Bytes | 9.2 temperature difference (K) | CRW |
| 23 | Channel H2 | Actual value | 2 Bytes | 9.1 temperature (°C) | CRWU |
| 24 | Channel H2 | Current actuating value | 1 Byte | 5.1 percentage (0..100%) | CRTU |
| 24 | Channel H2 | Operating mode preset | 1 Byte | 20.102 HVAC mode | CRW |
| 25 | Channel H2 | Presence | 1 Bit | 1.18 occupancy | CRW |
| 26 | Channel H2 | Window setting | 1 Bit | 1.19 window/door | CRW |
| 27 | Channel H2 | Current operating mode | 1 Byte | 20.102 HVAC mode | CRT |
| 28 | Channel H2 | Heating actuating value | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 28 | Channel H2 | Heating and cooling actuating value | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 29 | Channel H2 | Cooling actuating value | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 30 | Channel H2 | Heating = 0, cooling = 1 | 1 Bit | 1.1 switch | CRWU |
| 30 | Channel H2 | Heating = 1, cooling = 0 | 1 Bit | 1.100 heating/cooling | CRWU |
| 31 | Channel H2 | Current setpoint | 2 Bytes | 9.1 temperature (°C) | CRWT |
| 32 | Channel H2 | Report actuating value failure | 1 Bit | 1.5 alarm | CRTU |
| 32 | Channel H2 | Report actual value failure | 1 Bit | 1.5 alarm | CRTU |
| 33 | Channel H2 | Forced operation | 1 Bit | 1.3 enable | CRWU |
| 34 | Channel H2 | Overcurrent/short circuit | 1 Bit | 1.5 alarm | CRTU |
| 41 | Channel H3 | Continuous actuating value | 1 Byte | 5.1 percentage (0..100%) | CRWU |
| 41 | Channel H3 | Switching actuating value | 1 Bit | 1.1 switch | CRWU |
| 41 | Channel H3 | Base setpoint | 2 Bytes | 9.1 temperature (°C) | CRW |
| 42 | Channel H3 | Manual setpoint offset | 2 Bytes | 9.2 temperature difference (K) | CRW |
| 43 | Channel H3 | Actual value | 2 Bytes | 9.1 temperature (°C) | CRWU |
| 44 | Channel H3 | Current actuating value | 1 Byte | 5.1 percentage (0..100%) | CRTU |
| 44 | Channel H3 | Operating mode preset | 1 Byte | 20.102 HVAC mode | CRW |
| 45 | Channel H3 | Presence | 1 Bit | 1.18 occupancy | CRW |
| 46 | Channel H3 | Window setting | 1 Bit | 1.19 window/door | CRW |
| 47 | Channel H3 | Current operating mode | 1 Byte | 20.102 HVAC mode | CRT |
| 48 | Channel H3 | Heating actuating value | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 48 | Channel H3 | Heating and cooling actuating value | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 49 | Channel H3 | Cooling actuating value | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 50 | Channel H3 | Heating = 0, cooling = 1 | 1 Bit | 1.1 switch | CRWU |
| 50 | Channel H3 | Heating = 1, cooling = 0 | 1 Bit | 1.100 heating/cooling | CRWU |
| 51 | Channel H3 | Current setpoint | 2 Bytes | 9.1 temperature (°C) | CRWT |
| 52 | Channel H3 | Report actuating value failure | 1 Bit | 1.5 alarm | CRTU |
| 52 | Channel H3 | Report actual value failure | 1 Bit | 1.5 alarm | CRTU |
| 53 | Channel H3 | Forced operation | 1 Bit | 1.3 enable | CRWU |
| 54 | Channel H3 | Overcurrent/short circuit | 1 Bit | 1.5 alarm | CRTU |
| 61 | Channel H4 | Continuous actuating value | 1 Byte | 5.1 percentage (0..100%) | CRWU |
| 61 | Channel H4 | Switching actuating value | 1 Bit | 1.1 switch | CRWU |
| 61 | Channel H4 | Base setpoint | 2 Bytes | 9.1 temperature (°C) | CRW |
| 62 | Channel H4 | Manual setpoint offset | 2 Bytes | 9.2 temperature difference (K) | CRW |
| 63 | Channel H4 | Actual value | 2 Bytes | 9.1 temperature (°C) | CRWU |
| 64 | Channel H4 | Current actuating value | 1 Byte | 5.1 percentage (0..100%) | CRTU |
| 64 | Channel H4 | Operating mode preset | 1 Byte | 20.102 HVAC mode | CRW |
| 65 | Channel H4 | Presence | 1 Bit | 1.18 occupancy | CRW |
| 66 | Channel H4 | Window setting | 1 Bit | 1.19 window/door | CRW |
| 67 | Channel H4 | Current operating mode | 1 Byte | 20.102 HVAC mode | CRT |
| 68 | Channel H4 | Heating actuating value | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 68 | Channel H4 | Heating and cooling actuating value | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 69 | Channel H4 | Cooling actuating value | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 70 | Channel H4 | Heating = 0, cooling = 1 | 1 Bit | 1.1 switch | CRWU |
| 70 | Channel H4 | Heating = 1, cooling = 0 | 1 Bit | 1.100 heating/cooling | CRWU |
| 71 | Channel H4 | Current setpoint | 2 Bytes | 9.1 temperature (°C) | CRWT |
| 72 | Channel H4 | Report actuating value failure | 1 Bit | 1.5 alarm | CRTU |
| 72 | Channel H4 | Report actual value failure | 1 Bit | 1.5 alarm | CRTU |
| 73 | Channel H4 | Forced operation | 1 Bit | 1.3 enable | CRWU |
| 74 | Channel H4 | Overcurrent/short circuit | 1 Bit | 1.5 alarm | CRTU |
| 81 | Channel H5 | Continuous actuating value | 1 Byte | 5.1 percentage (0..100%) | CRWU |
| 81 | Channel H5 | Switching actuating value | 1 Bit | 1.1 switch | CRWU |
| 81 | Channel H5 | Base setpoint | 2 Bytes | 9.1 temperature (°C) | CRW |
| 82 | Channel H5 | Manual setpoint offset | 2 Bytes | 9.2 temperature difference (K) | CRW |
| 83 | Channel H5 | Actual value | 2 Bytes | 9.1 temperature (°C) | CRWU |
| 84 | Channel H5 | Current actuating value | 1 Byte | 5.1 percentage (0..100%) | CRTU |
| 84 | Channel H5 | Operating mode preset | 1 Byte | 20.102 HVAC mode | CRW |
| 85 | Channel H5 | Presence | 1 Bit | 1.18 occupancy | CRW |
| 86 | Channel H5 | Window setting | 1 Bit | 1.19 window/door | CRW |
| 87 | Channel H5 | Current operating mode | 1 Byte | 20.102 HVAC mode | CRT |
| 88 | Channel H5 | Heating actuating value | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 88 | Channel H5 | Heating and cooling actuating value | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 89 | Channel H5 | Cooling actuating value | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 90 | Channel H5 | Heating = 0, cooling = 1 | 1 Bit | 1.1 switch | CRWU |
| 90 | Channel H5 | Heating = 1, cooling = 0 | 1 Bit | 1.100 heating/cooling | CRWU |
| 91 | Channel H5 | Current setpoint | 2 Bytes | 9.1 temperature (°C) | CRWT |
| 92 | Channel H5 | Report actuating value failure | 1 Bit | 1.5 alarm | CRTU |
| 92 | Channel H5 | Report actual value failure | 1 Bit | 1.5 alarm | CRTU |
| 93 | Channel H5 | Forced operation | 1 Bit | 1.3 enable | CRWU |
| 94 | Channel H5 | Overcurrent/short circuit | 1 Bit | 1.5 alarm | CRTU |
| 101 | Channel H6 | Continuous actuating value | 1 Byte | 5.1 percentage (0..100%) | CRWU |
| 101 | Channel H6 | Switching actuating value | 1 Bit | 1.1 switch | CRWU |
| 101 | Channel H6 | Base setpoint | 2 Bytes | 9.1 temperature (°C) | CRW |
| 102 | Channel H6 | Manual setpoint offset | 2 Bytes | 9.2 temperature difference (K) | CRW |
| 103 | Channel H6 | Actual value | 2 Bytes | 9.1 temperature (°C) | CRWU |
| 104 | Channel H6 | Current actuating value | 1 Byte | 5.1 percentage (0..100%) | CRTU |
| 104 | Channel H6 | Operating mode preset | 1 Byte | 20.102 HVAC mode | CRW |
| 105 | Channel H6 | Presence | 1 Bit | 1.18 occupancy | CRW |
| 106 | Channel H6 | Window setting | 1 Bit | 1.19 window/door | CRW |
| 107 | Channel H6 | Current operating mode | 1 Byte | 20.102 HVAC mode | CRT |
| 108 | Channel H6 | Heating actuating value | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 108 | Channel H6 | Heating and cooling actuating value | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 109 | Channel H6 | Cooling actuating value | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 110 | Channel H6 | Heating = 0, cooling = 1 | 1 Bit | 1.1 switch | CRWU |
| 110 | Channel H6 | Heating = 1, cooling = 0 | 1 Bit | 1.100 heating/cooling | CRWU |
| 111 | Channel H6 | Current setpoint | 2 Bytes | 9.1 temperature (°C) | CRWT |
| 112 | Channel H6 | Report actuating value failure | 1 Bit | 1.5 alarm | CRTU |
| 112 | Channel H6 | Report actual value failure | 1 Bit | 1.5 alarm | CRTU |
| 113 | Channel H6 | Forced operation | 1 Bit | 1.3 enable | CRWU |
| 114 | Channel H6 | Overcurrent/short circuit | 1 Bit | 1.5 alarm | CRTU |
| 241 | H1 - H6 | Summer mode ON/OFF | 1 Bit | 1.3 enable | CRWU |
| 242 | H1 - H6 | Highest actuating value | 1 Byte | 5.1 percentage (0..100%) | CRWTU |
| 244 | H1 - H6 | Pump ON/OFF | 1 Bit | 1.1 switch | CRTU |
| 245 | H1 - H6 | Pump relay status | 1 Bit | 1.1 switch | CRTU |
| 246 | H1 - H6 | Outside temperature | 2 Bytes | 9.1 temperature (°C) | CRWU |
| 247 | H1 - H6 | Outside temperature failure | 1 Bit | 1.5 alarm | CRTU |
| 248 | H1 - H6 | Manual | 1 Bit | 1.1 switch | CRWTU |
| 249 | Version of bus coupling unit | Send | 14 Bytes | 16.1 Character String (ISO 8859-1) | CRTU |
| 250 | Firmware version | Send | 14 Bytes | 16.1 Character String (ISO 8859-1) | CRTU |
Parameters (105)
| Parameter | Type | Default |
|---|---|---|
| Channel function | list | Heating actuator |
| Type of actuating value | list | Continuous.. |
| Include in summer mode | list | no |
| Activate valve protection | list | yes |
| Valve protection disable telegram | list | 1 = Block (standard) |
| Monitoring actuating value | list | no |
| Execute valve protection | list | Always |
| Monitor actual value | list | no |
| - | list | Minutes |
| Activate compulsory function | list | no |
| Type of valve control | list | switch output |
| Actuator direction of operation | list | Standard: 1 = Open valve |
| Output voltage at 0% | list | 0 V |
| Output voltage at 100% | list | 10 V |
| Output voltage at 100% | list | 0 V |
| Output voltage at 0% | list | 10 V |
| Switchover between heating and cooling | list | automatic |
| Channel processes actuating value for | list | Heating |
| Output of the cooling actuating value | list | On separate object |
| Minimum actuating value | list | 0% |
| Maximum actuating value | list | 90% |
| Send heating actuating value in cycles | list | With change of 5 % |
| Take channel into account for highest actuating value | list | yes |
| Send current actuating value in cycles | list | Not cyclical, only in the event of change |
| Actuating value when value violates the min./max. actuating value | list | 0 = 0%, otherwise use set actuating values |
| Send current actuating value | list | With change of 5 % |
| Control pump | list | via relay |
| Actuation cycle time (PWM period) | list | 10 min |
| Control | list | standard |
| Control functions used | list | Only heating control |
| Operating mode after reset | list | Standby |
| Type of presence sensor | list | Presence detector |
| Comfort extension by presence buttons in night mode | list | 2 hours |
| Sends the current operating mode in cycles | list | Not cyclical, only in the event of change |
| System type | list | Radiator heating system |
| Send heating actuating value in cycles | list | Not cyclical, only in the event of change |
| Setting the control parameters | list | Via installation type |
| Proportional band of heating control | list | 2 K |
| Integrated time of heating control | list | 10 h |
| Base setpoint value after loading the application | list | 21 °C |
| Minimum valid base setpoint value | list | 10 °C |
| Maximum valid base setpoint value | list | 32 °C |
| Reduction in standby mode (during heating) | list | 1,5 K |
| Reduction in night mode (during heating) | list | 5 K |
| Setpoint value for frost protection operation (during heating) | list | 5 °C |
| Maximum valid setpoint offset | list | +/- 5 K |
| Setpoint offset applies | list | In comfort, standby and night mode |
| Current setpoint value in comfort mode | list | Sends actual value (heating < > cooling) |
| Send current setpoint value in cycles | list | Not cyclical, only in the event of change |
| Proportional band of the cooling control | list | 4 K |
| Integrated time of the cooling control | list | 180 min. |
| System type | list | Cooling surface |
| Send cooling actuating value | list | With change of 5 % |
| Sends the cooling actuating value in cycles | list | Not cyclical, only in the event of change |
| Format object heating/cooling | list | DPT100 (Heating= 1 / Cooling=0) |
| Dead zone between heating and cooling | list | 2 K |
| Increase in standby mode (during cooling) | list | 1,5 K |
| Increase in night mode (during cooling) | list | 5 K |
| Setpoint value for heat protection mode (during cooling) | list | 42 °C i.e. no real heat protection |
| Actuating value for emergency program is | list | Fixed |
| Emergency program active when outside temperature below | list | 10 °C |
| Max. actuating value in emergency program | list | 40% |
| Fixed emergency program with failure of outside temperature | list | 20% |
| Fixed emergency program in winter mode | list | 20% |
| Actuating value in the forced operation mode | list | 0% |
| Forced telegram | list | 1 = Force (standard) |
| Type | list | HMT 6 S.. |
| Monitoring time | list | 30 min. |
| Status of monitoring | list | Report only in the event of malfunction |
| Send status in cycles | list | no |
| Cycle time | list | Every 30 min. |
| Only switch on relay if at least (only for switch output) | list | one input actuating value is > 0 % |
| Switch-off delay | list | 10 min |
| Send relay status cyclically | list | no, only in the event of change |
| Switch on telegram only if at least (only for switch output) | list | one input actuating value is > 0 % |
| Send pump control in cycles | list | no, only in the event of change |
| Function of manual push button | list | valid until reset via object |
| Manual operation of channels | list | enabled |
| Send highest actuating value (If continuous actuating value used) | list | only if own actuating value is greater |
| Monitor actuating value | list | no |
| Sends heating actuating value | list | With change of 5 % |
| Actuating value when value violates the min./max. actuating value | list | 0 = 0%, otherwise use set actuating values |
| Comfort extension by presence button in night mode | list | 2 hours |
| Sends the current operating mode in cycles | list | Not cyclical, only in the event of change |
| Installation type | list | Radiator heating system |
| Sends heating actuating value in cycles | list | Not cyclical, only in the event of change |
| Proportional band of heating controller | list | 2 K |
| Integrated time of heating controller | list | 10 h |
| Base setpoint after loading the application | list | 21 °C |
| Minimum valid base setpoint | list | 10 °C |
| Maximum valid base setpoint | list | 32 °C |
| Reduction in standby mode (during heating) | list | 1,5 K |
| Setpoint for frost protection mode (during heating) | list | 5 °C |
| Current setpoint in comfort mode | list | Sends actual value (heating < > cooling) |
| Send current setpoint in cycles | list | Not cyclical, only in the event of change |
| Proportional band of the cooling controller | list | 4 K |
| Integrated time of the cooling controller | list | 180 min. |
| Installation type | list | Cooling surface |
| Sends cooling actuating value | list | With change of 5 % |
| Sends cooling actuating value in cycles | list | Not cyclical, only in the event of change |
| Increase in standby mode (during cooling) | list | 1,5 K |
| Setpoint for heat protection mode (during cooling) | list | 42 °C i.e. no real heat protection |
| Emergency program active when outside temperature below | list | 10 °C |
| Fixed emergency program at failure of outside temperature | list | 20% |
| Actuating value in the forced operation | list | 0% |
Version history
| Application | App no | Fingerprint | First seen | Size | File |
|---|---|---|---|---|---|
| Floor heating-Controller, 6-fold/1.0a 1.0 latest | $490A | 33AA | 2026-11-25 | 112 KB | Download |
About this file
This is the official ETS product database for the ABB AG - STOTZ-KONTAKT VAA/A6.24.2 Floor heating-Controller,6-fold (2CDG 120 061 R0011), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.
More from ABB AG - STOTZ-KONTAKT
- PS5604-KNX AC500 1SAP 195 800 R0101
- RDF/A x.1 RTR fan coil with display, SM 2CDG 006 138 R001x
- ES/S4.1.2.1 Electronic Switch Actuator,4f,1A,MDRC 2CDG 110 058 R0011
- ES/S8.1.2.1 Electronic Switch Actuator,8f,1A,MDRC 2CDG 110 059 R0011
- VAA/S6.230.2.1 Valve Drive Actuator, 6f, 230V,MDRC 2CDG 110 116 R0011
- VAA/S12.230.2.1 Valve Drive Actuator, 12f, 230V 2CDG 110 117 R0011
- FCL/S1.6.1.1 Blower Actuator, 1f, 6 A, MDRC 2CDG 110 163 R0011
- FCL/S2.6.1.1 Blower Actuator, 2f, 6 A, MDRC 2CDG 110 164 R0011
- AC/S1.1.1 Application Controller,Basic 2CDG 110 205 R0011
- AC/S1.2.1 Application Controller,BACnet 2CDG 110 206 R0011
- FCC/S1.4.1.1 Fan Coil Controller,PWM,3-speed,2-pipe,MDRC 2CDG 110 209 R0011
- FCC/S1.1.1.1 Fan Coil Controller,PWM,3-speed,MDRC 2CDG 110 210 R0011