ABB AG - STOTZ-KONTAKT 2CDG 110 311 R0011 MPG/S8.1.1 KNX/MP-Bus Controller

MPG/S8.1.1 KNX/MP-Bus Controller 2CDG 110 311 R0011

ABB AG - STOTZ-KONTAKT · Order number 2CDG 110 311 R0011 · Heating, Ventilation and Air Conditioning › Central HVAC Controllers

Download .knxprod KNX/MP-Bus Controller/1.0 1.0 · 3.0 MB

Product

ManufacturerABB AG - STOTZ-KONTAKT
Product nameMPG/S8.1.1 KNX/MP-Bus Controller
Order number2CDG 110 311 R0011
HardwareMPG/S8.1.1 KNX/MP-Bus Controller
MediumTwisted Pair
Bus current (mA)10
Rail mountedYes
Width (mm)36
RegistrationRegistered · 2025-10-27
Languagesen-US, de-DE, es-ES, fr-FR, it-IT, nl-NL, pl-PL, ru-RU
Catalog entryM-0002_H-2CDG.20110.20311.20R0011-0_HP-B12A-10-9D3B-B12A-50-3D82_CI-2CDG.20110.20311.20R0011-1
Fingerprint9D3B
SHA-2567c6ec809364123c0a7ab1843741203f64a3680e77a9e77ffd053909a0d58fdfc
First seen2026-11-25
Markets59 markets

Application program: KNX/MP-Bus Controller/1.0 1.0

Application number$B12A
Version1.0
Mask versionMV-07B0 (System B)
KNX Data SecureYes
Minimum ETS version5.0
Parameters7106
Group objects5340
Group objects (5340)
NoNameFunctionSizeDPTFlags
1Central - General: In operation1 Bit1.2 booleanCT
2Central - General: Request status values1 Bit1.17 triggerCWU
3Central - Date/time: Set time3 Bytes10.1 time of dayCWU
3Central - Date/time: Set date/time8 Bytes19.1 date timeCWU
4Central - Date/time: Set date3 Bytes11.1 dateCWU
5Central - Date/time: Poll time1 Bit1.17 triggerCT
10Central - General: DCA configuration access is active1 Bit1.2 booleanCRT
11Central - General: MP-Bus voltage failure1 Bit1.5 alarmCRT
12Central - General: Communication error1 Bit1.5 alarmCRT
13Central - General: Addressing error1 Bit1.5 alarmCRT
14Central - General: Configuration error1 Bit1.5 alarmCRT
15Central - General: MP-Bus device error4 Bytes27.1 bit-combined info on/offCRT
16Channel 1 - Air VAV compact controller: {{0}}Setpoint1 Byte5.1 percentage (0..100%)CWTUI
16Channel 1 - Air VAV compact controller: {{0}}Control value1 Byte5.1 percentage (0..100%)CWTUI
16Channel 1 - Air VAV compact controller: {{0}}Heating control value1 Byte5.1 percentage (0..100%)CWTUI
16Channel 1 - Air rotary/damper actuator: {{0}}Setpoint1 Byte5.1 percentage (0..100%)CWTUI
16Channel 1 - Air rotary/damper actuator: {{0}}Control value1 Byte5.1 percentage (0..100%)CWTUI
16Channel 1 - Air rotary/damper actuator: {{0}}Heating control value1 Byte5.1 percentage (0..100%)CWTUI
16Channel 1 - Water rotary actuator: {{0}}Setpoint1 Byte5.1 percentage (0..100%)CWTUI
16Channel 1 - Water rotary actuator: {{0}}Control value1 Byte5.1 percentage (0..100%)CWTUI
16Channel 1 - Water rotary actuator: {{0}}Heating control value1 Byte5.1 percentage (0..100%)CWTUI
16Channel 1 - VAV universal controller: {{0}}Setpoint1 Byte5.1 percentage (0..100%)CWTUI
16Channel 1 - Water 2-way valve: {{0}}Setpoint1 Byte5.1 percentage (0..100%)CWTUI
16Channel 1 - Thermal energy meter: {{0}}Setpoint1 Byte5.1 percentage (0..100%)CWTUI
16Channel 1 - Room control unit: {{0}}Confirm room temperature setpoint (absolute)2 Bytes9.1 temperature (°C)CWTUI
16Channel 1 - Room control unit: {{0}}Confirm room temperature setpoint (relative)2 Bytes9.2 temperature difference (K)CWTUI
17Channel 1 - Air VAV compact controller: {{0}}Cooling control value1 Byte5.1 percentage (0..100%)CWTUI
17Channel 1 - Air rotary/damper actuator: {{0}}Cooling control value1 Byte5.1 percentage (0..100%)CWTUI
17Channel 1 - Water rotary actuator: {{0}}Cooling control value1 Byte5.1 percentage (0..100%)CWTUI
17Channel 1 - VAV universal controller: {{0}}Override control1 ByteCWTUI
17Channel 1 - Water 2-way valve: {{0}}Setpoint absolute differential pressure4 Bytes14.58 pressure (Pa)CWTUI
17Channel 1 - Thermal energy meter: {{0}}Setpoint absolute differential pressure4 Bytes14.58 pressure (Pa)CWTUI
17Channel 1 - Room control unit: {{0}}Basic setpoint2 Bytes9.1 temperature (°C)CWTUI
18Channel 1 - Air VAV compact controller: {{0}}Heating/cooling changeover1 Bit1.100 cooling/heatingCWTUI
18Channel 1 - Air rotary/damper actuator: {{0}}Heating/cooling changeover1 Bit1.100 cooling/heatingCWTUI
18Channel 1 - Water rotary actuator: {{0}}Heating/cooling changeover1 Bit1.100 cooling/heatingCWTUI
18Channel 1 - VAV universal controller: {{0}}Start adjustment1 Bit1.17 triggerCW
18Channel 1 - Water 2-way valve: {{0}}Minimum flow rate1 Byte5.1 percentage (0..100%)CWTUI
18Channel 1 - Thermal energy meter: {{0}}Minimum flow rate1 Byte5.1 percentage (0..100%)CWTUI
18Channel 1 - Room control unit: {{0}}Confirm fan speed1 Byte5.1 percentage (0..100%)CWTUI
19Channel 1 - Air VAV compact controller: {{0}}Activate heating1 Bit1.3 enableCWTUI
19Channel 1 - Air rotary/damper actuator: {{0}}Activate heating1 Bit1.3 enableCWTUI
19Channel 1 - Water rotary actuator: {{0}}Activate heating1 Bit1.3 enableCWTUI
19Channel 1 - VAV universal controller: {{0}}Start synchronization1 Bit1.17 triggerCW
19Channel 1 - Water 2-way valve: {{0}}Maximum flow rate1 Byte5.1 percentage (0..100%)CWTUI
19Channel 1 - Thermal energy meter: {{0}}Maximum flow rate1 Byte5.1 percentage (0..100%)CWTUI
19Channel 1 - Room control unit: {{0}}Request fan automatic mode1 Bit1.3 enableCWTUI
20Channel 1 - Air VAV compact controller: {{0}}Activate cooling1 Bit1.3 enableCWTUI
20Channel 1 - Air rotary/damper actuator: {{0}}Activate cooling1 Bit1.3 enableCWTUI
20Channel 1 - Water rotary actuator: {{0}}Activate cooling1 Bit1.3 enableCWTUI
20Channel 1 - VAV universal controller: {{0}}Minimum flow rate1 Byte5.1 percentage (0..100%)CWTUI
20Channel 1 - VAV universal controller: {{0}}Minimum differential pressure1 Byte5.1 percentage (0..100%)CWTUI
20Channel 1 - Water 2-way valve: {{0}}Maximum power limit1 Byte5.1 percentage (0..100%)CWTUI
20Channel 1 - Thermal energy meter: {{0}}Maximum power limit1 Byte5.1 percentage (0..100%)CWTUI
20Channel 1 - Room control unit: {{0}}Display warning icon1 Bit1.3 enableCWTUI
21Channel 1 - Air VAV compact controller: {{0}}Override control1 ByteCWTUI
21Channel 1 - Air rotary/damper actuator: {{0}}Override control1 ByteCWTUI
21Channel 1 - Water rotary actuator: {{0}}Override control1 ByteCWTUI
21Channel 1 - VAV universal controller: {{0}}Maximum flow rate1 Byte5.1 percentage (0..100%)CWTUI
21Channel 1 - VAV universal controller: {{0}}Maximum differential pressure1 Byte5.1 percentage (0..100%)CWTUI
21Channel 1 - Water 2-way valve: {{0}}Activate Delta-T Manager1 Bit1.3 enableCWTUI
21Channel 1 - Thermal energy meter: {{0}}Activate Delta-T Manager1 Bit1.3 enableCWTUI
21Channel 1 - Room control unit: {{0}}Display window icon1 Bit1.3 enableCWTUI
22Channel 1 - Air VAV compact controller: {{0}}Minimum position1 Byte5.1 percentage (0..100%)CWTUI
22Channel 1 - Air VAV compact controller: {{0}}Minimum flow rate1 Byte5.1 percentage (0..100%)CWTUI
22Channel 1 - Air rotary/damper actuator: {{0}}Minimum position1 Byte5.1 percentage (0..100%)CWTUI
22Channel 1 - Air rotary/damper actuator: {{0}}Minimum flow rate1 Byte5.1 percentage (0..100%)CWTUI
22Channel 1 - Water rotary actuator: {{0}}Minimum position1 Byte5.1 percentage (0..100%)CWTUI
22Channel 1 - Water rotary actuator: {{0}}Minimum flow rate1 Byte5.1 percentage (0..100%)CWTUI
22Channel 1 - VAV universal controller: {{0}}Status Analog input signal1 Byte5.1 percentage (0..100%)CRT
22Channel 1 - Water 2-way valve: {{0}}Activate Delta-T Manager flow-dependent adjustment (scaling)1 Bit1.3 enableCWTUI
22Channel 1 - Thermal energy meter: {{0}}Activate Delta-T Manager flow-dependent adjustment (scaling)1 Bit1.3 enableCWTUI
22Channel 1 - Room control unit: {{0}}Status RTC controller2 Bytes22.103 combined status RTCCWTUI
23Channel 1 - Air VAV compact controller: {{0}}Maximum position1 Byte5.1 percentage (0..100%)CWTUI
23Channel 1 - Air VAV compact controller: {{0}}Maximum flow rate1 Byte5.1 percentage (0..100%)CWTUI
23Channel 1 - Air rotary/damper actuator: {{0}}Maximum position1 Byte5.1 percentage (0..100%)CWTUI
23Channel 1 - Air rotary/damper actuator: {{0}}Maximum flow rate1 Byte5.1 percentage (0..100%)CWTUI
23Channel 1 - Water rotary actuator: {{0}}Maximum position1 Byte5.1 percentage (0..100%)CWTUI
23Channel 1 - Water rotary actuator: {{0}}Maximum flow rate1 Byte5.1 percentage (0..100%)CWTUI
23Channel 1 - VAV universal controller: {{0}}Status Relative position1 Byte5.1 percentage (0..100%)CRT
23Channel 1 - Water 2-way valve: {{0}}Setpoint Delta-T limitation2 Bytes9.2 temperature difference (K)CWTUI
23Channel 1 - Thermal energy meter: {{0}}Setpoint Delta-T limitation2 Bytes9.2 temperature difference (K)CWTUI
23Channel 1 - Room control unit: {{0}}Receive status Heating1 Bit1.3 enableCWTUI
24Channel 1 - Air VAV compact controller: {{0}}Start test run1 Bit1.17 triggerCW
24Channel 1 - Air rotary/damper actuator: {{0}}Start test run1 Bit1.17 triggerCW
24Channel 1 - Water rotary actuator: {{0}}Start test run1 Bit1.17 triggerCW
24Channel 1 - VAV universal controller: {{0}}Status Absolute position2 Bytes8.11 rotation angle (°)CRT
24Channel 1 - Water 2-way valve: {{0}}Setpoint absolute flow at Delta-T4 Bytes14.1201 volume flux for meters (1/ls)CWTUI
24Channel 1 - Thermal energy meter: {{0}}Setpoint absolute flow at Delta-T4 Bytes14.1201 volume flux for meters (1/ls)CWTUI
24Channel 1 - Room control unit: {{0}}Receive status Cooling1 Bit1.3 enableCWTUI
25Channel 1 - Air VAV compact controller: {{0}}Start adjustment1 Bit1.17 triggerCW
25Channel 1 - Air rotary/damper actuator: {{0}}Start adjustment1 Bit1.17 triggerCW
25Channel 1 - Water rotary actuator: {{0}}Start adjustment1 Bit1.17 triggerCW
25Channel 1 - VAV universal controller: {{0}}Status Minimum flow rate1 Byte5.1 percentage (0..100%)CRT
25Channel 1 - VAV universal controller: {{0}}Status Minimum differential pressure1 Byte5.1 percentage (0..100%)CRT
25Channel 1 - Water 2-way valve: {{0}}Start synchronization1 Bit1.17 triggerCW
25Channel 1 - Thermal energy meter: {{0}}Start synchronization1 Bit1.17 triggerCW
25Channel 1 - Room control unit: {{0}}Confirm RTR operating mode1 Byte20.102 HVAC modeCWTUI
26Channel 1 - Air VAV compact controller: {{0}}Status Relative position1 Byte5.1 percentage (0..100%)CRT
26Channel 1 - Air rotary/damper actuator: {{0}}Status Relative position1 Byte5.1 percentage (0..100%)CRT
26Channel 1 - Water rotary actuator: {{0}}Status Relative position1 Byte5.1 percentage (0..100%)CRT
26Channel 1 - VAV universal controller: {{0}}Status Maximum flow rate1 Byte5.1 percentage (0..100%)CRT
26Channel 1 - VAV universal controller: {{0}}Status Maximum differential pressure1 Byte5.1 percentage (0..100%)CRT
26Channel 1 - Water 2-way valve: {{0}}Override control1 ByteCWTUI
26Channel 1 - Thermal energy meter: {{0}}Override control1 ByteCWTUI
26Channel 1 - Room control unit: {{0}}Block local operation1 Bit1.3 enableCWTUI
27Channel 1 - Air VAV compact controller: {{0}}Status Absolute position (rotation angle)2 Bytes8.11 rotation angle (°)CRT
27Channel 1 - Air VAV compact controller: {{0}}Status Absolute position (millimeters)2 Bytes7.11 length (mm)CRT
27Channel 1 - Air rotary/damper actuator: {{0}}Status Absolute position (rotation angle)2 Bytes8.11 rotation angle (°)CRT
27Channel 1 - Air rotary/damper actuator: {{0}}Status Absolute position (millimeters)2 Bytes7.11 length (mm)CRT
27Channel 1 - Water rotary actuator: {{0}}Status Absolute position (rotation angle)2 Bytes8.11 rotation angle (°)CRT
27Channel 1 - Water rotary actuator: {{0}}Status Absolute position (millimeters)2 Bytes7.11 length (mm)CRT
27Channel 1 - VAV universal controller: {{0}}Status Relative flow rate1 Byte5.1 percentage (0..100%)CRT
27Channel 1 - Water 2-way valve: {{0}}Status Analog input signal1 Byte5.1 percentage (0..100%)CRT
27Channel 1 - Thermal energy meter: {{0}}Status Analog input signal1 Byte5.1 percentage (0..100%)CRT
27Channel 1 - Room control unit: {{0}}Display Boost mode1 Bit1.1 switchCWTUI
28Channel 1 - Air VAV compact controller: {{0}}Status Nominal range (rotation angle)2 Bytes8.11 rotation angle (°)CRT
28Channel 1 - Air VAV compact controller: {{0}}Status Nominal range (millimeters)2 Bytes7.11 length (mm)CRT
28Channel 1 - Air rotary/damper actuator: {{0}}Status Nominal range (rotation angle)2 Bytes8.11 rotation angle (°)CRT
28Channel 1 - Air rotary/damper actuator: {{0}}Status Nominal range (millimeters)2 Bytes7.11 length (mm)CRT
28Channel 1 - Water rotary actuator: {{0}}Status Nominal range (rotation angle)2 Bytes8.11 rotation angle (°)CRT
28Channel 1 - Water rotary actuator: {{0}}Status Nominal range (millimeters)2 Bytes7.11 length (mm)CRT
28Channel 1 - VAV universal controller: {{0}}Status Absolute flow rate4 Bytes14.77 volume flux (m³/s)CRT
28Channel 1 - VAV universal controller: {{0}}Status Absolute flow rate2 Bytes9.9 air flow (m³/h)CRT
28Channel 1 - Water 2-way valve: {{0}}Status Relative position1 Byte5.1 percentage (0..100%)CRT
28Channel 1 - Thermal energy meter: {{0}}Status Relative position1 Byte5.1 percentage (0..100%)CRT
28Channel 1 - Room control unit: {{0}}Status Room temperature2 Bytes9.1 temperature (°C)CRT
29Channel 1 - Air VAV compact controller: {{0}}Status Relative flow rate1 Byte5.1 percentage (0..100%)CRT
29Channel 1 - Air rotary/damper actuator: {{0}}Status Relative flow rate1 Byte5.1 percentage (0..100%)CRT
29Channel 1 - Water rotary actuator: {{0}}Status Relative flow rate1 Byte5.1 percentage (0..100%)CRT
29Channel 1 - VAV universal controller: {{0}}Status Nominal flow rate4 Bytes14.77 volume flux (m³/s)CRT
29Channel 1 - VAV universal controller: {{0}}Status Nominal flow rate2 Bytes9.9 air flow (m³/h)CRT
29Channel 1 - Water 2-way valve: {{0}}Status Absolute position2 Bytes8.11 rotation angle (°)CRT
29Channel 1 - Thermal energy meter: {{0}}Status Absolute position2 Bytes8.11 rotation angle (°)CRT
29Channel 1 - Room control unit: {{0}}Status Relative humidity1 Byte5.1 percentage (0..100%)CRT
30Channel 1 - Air VAV compact controller: {{0}}Status Absolute flow rate4 Bytes14.77 volume flux (m³/s)CRT
30Channel 1 - Air VAV compact controller: {{0}}Status Absolute flow rate2 Bytes9.9 air flow (m³/h)CRT
30Channel 1 - Air rotary/damper actuator: {{0}}Status Absolute flow rate4 Bytes14.77 volume flux (m³/s)CRT
30Channel 1 - Air rotary/damper actuator: {{0}}Status Absolute flow rate2 Bytes9.9 air flow (m³/h)CRT
30Channel 1 - Water rotary actuator: {{0}}Status Absolute flow rate4 Bytes14.77 volume flux (m³/s)CRT
30Channel 1 - Water rotary actuator: {{0}}Status Absolute flow rate2 Bytes9.9 air flow (m³/h)CRT
30Channel 1 - VAV universal controller: {{0}}Status Relative differential pressure2 Bytes8.10 percentage difference (%)CRT
30Channel 1 - Water 2-way valve: {{0}}Status Relative flow rate1 Byte5.1 percentage (0..100%)CRT
30Channel 1 - Water 2-way valve: {{0}}Status Relative flow rate2 Bytes8.10 percentage difference (%)CRT
30Channel 1 - Thermal energy meter: {{0}}Status Relative flow rate1 Byte5.1 percentage (0..100%)CRT
30Channel 1 - Thermal energy meter: {{0}}Status Relative flow rate2 Bytes8.10 percentage difference (%)CRT
30Channel 1 - Room control unit: {{0}}CO2 value2 Bytes9.8 parts/million (ppm)CRT
31Channel 1 - Air VAV compact controller: {{0}}Status Nominal flow rate4 Bytes14.77 volume flux (m³/s)CRT
31Channel 1 - Air VAV compact controller: {{0}}Status Nominal flow rate2 Bytes9.9 air flow (m³/h)CRT
31Channel 1 - Air rotary/damper actuator: {{0}}Status Nominal flow rate4 Bytes14.77 volume flux (m³/s)CRT
31Channel 1 - Air rotary/damper actuator: {{0}}Status Nominal flow rate2 Bytes9.9 air flow (m³/h)CRT
31Channel 1 - Water rotary actuator: {{0}}Status Nominal flow rate4 Bytes14.77 volume flux (m³/s)CRT
31Channel 1 - Water rotary actuator: {{0}}Status Nominal flow rate2 Bytes9.9 air flow (m³/h)CRT
31Channel 1 - VAV universal controller: {{0}}Status Absolute differential pressure4 Bytes14.58 pressure (Pa)CRT
31Channel 1 - Water 2-way valve: {{0}}Status Absolute flow rate4 Bytes14.1201 volume flux for meters (1/ls)CRT
31Channel 1 - Thermal energy meter: {{0}}Status Absolute flow rate4 Bytes14.1201 volume flux for meters (1/ls)CRT
31Channel 1 - Room control unit: {{0}}Air quality OK1 Bit1.2 booleanCRT
32Channel 1 - Air VAV compact controller: {{0}}Status Minimum position1 Byte5.1 percentage (0..100%)CRT
32Channel 1 - Air VAV compact controller: {{0}}Status Minimum flow rate1 Byte5.1 percentage (0..100%)CRT
32Channel 1 - Air rotary/damper actuator: {{0}}Status Minimum position1 Byte5.1 percentage (0..100%)CRT
32Channel 1 - Air rotary/damper actuator: {{0}}Status Minimum flow rate1 Byte5.1 percentage (0..100%)CRT
32Channel 1 - Water rotary actuator: {{0}}Status Minimum position1 Byte5.1 percentage (0..100%)CRT
32Channel 1 - Water rotary actuator: {{0}}Status Minimum flow rate1 Byte5.1 percentage (0..100%)CRT
32Channel 1 - VAV universal controller: {{0}}Status Nominal differential pressure4 Bytes14.58 pressure (Pa)CRT
32Channel 1 - Water 2-way valve: {{0}}Status Minimum flow rate1 Byte5.1 percentage (0..100%)CRT
32Channel 1 - Thermal energy meter: {{0}}Status Minimum flow rate1 Byte5.1 percentage (0..100%)CRT
32Channel 1 - Room control unit: {{0}}Air quality warning1 Bit1.2 booleanCRT
33Channel 1 - Air VAV compact controller: {{0}}Status Maximum position1 Byte5.1 percentage (0..100%)CRT
33Channel 1 - Air VAV compact controller: {{0}}Status Maximum flow rate1 Byte5.1 percentage (0..100%)CRT
33Channel 1 - Air rotary/damper actuator: {{0}}Status Maximum position1 Byte5.1 percentage (0..100%)CRT
33Channel 1 - Air rotary/damper actuator: {{0}}Status Maximum flow rate1 Byte5.1 percentage (0..100%)CRT
33Channel 1 - Water rotary actuator: {{0}}Status Maximum position1 Byte5.1 percentage (0..100%)CRT
33Channel 1 - Water rotary actuator: {{0}}Status Maximum flow rate1 Byte5.1 percentage (0..100%)CRT
33Channel 1 - VAV universal controller: {{0}}Sensor value (voltage)2 Bytes9.20 voltage (mV)CRT
33Channel 1 - VAV universal controller: {{0}}Sensor value (percent)1 Byte5.1 percentage (0..100%)CRT
33Channel 1 - VAV universal controller: {{0}}Sensor value (resistance)4 Bytes14.60 resistance (Ω)CRT
33Channel 1 - VAV universal controller: {{0}}Sensor value (switch)1 Bit1.1 switchCRT
33Channel 1 - VAV universal controller: {{0}}Sensor value (temperature)2 Bytes9.1 temperature (°C)CRT
33Channel 1 - VAV universal controller: {{0}}Sensor value (humidity)2 Bytes9.7 humidity (%)CRT
33Channel 1 - VAV universal controller: {{0}}Sensor value (humidity)1 Byte5.1 percentage (0..100%)CRT
33Channel 1 - VAV universal controller: {{0}}Sensor value (air quality)2 Bytes9.8 parts/million (ppm)CRT
33Channel 1 - VAV universal controller: {{0}}Sensor value (dew point alarm)1 Bit1.5 alarmCRT
33Channel 1 - Water 2-way valve: {{0}}Status Maximum flow rate1 Byte5.1 percentage (0..100%)CRT
33Channel 1 - Thermal energy meter: {{0}}Status Maximum flow rate1 Byte5.1 percentage (0..100%)CRT
33Channel 1 - Room control unit: {{0}}Air quality alarm1 Bit1.2 booleanCRT
34Channel 1 - Air VAV compact controller: {{0}}Sensor value (voltage)2 Bytes9.20 voltage (mV)CRT
34Channel 1 - Air VAV compact controller: {{0}}Sensor value (percent)1 Byte5.1 percentage (0..100%)CRT
34Channel 1 - Air VAV compact controller: {{0}}Sensor value (resistance)4 Bytes14.60 resistance (Ω)CRT
34Channel 1 - Air VAV compact controller: {{0}}Sensor value (switch)1 Bit1.1 switchCRT
34Channel 1 - Air VAV compact controller: {{0}}Sensor value (temperature)2 Bytes9.1 temperature (°C)CRT
34Channel 1 - Air VAV compact controller: {{0}}Sensor value (humidity)2 Bytes9.7 humidity (%)CRT
34Channel 1 - Air VAV compact controller: {{0}}Sensor value (humidity)1 Byte5.1 percentage (0..100%)CRT
34Channel 1 - Air VAV compact controller: {{0}}Sensor value (air quality)2 Bytes9.8 parts/million (ppm)CRT
34Channel 1 - Air VAV compact controller: {{0}}Sensor value (dew point alarm)1 Bit1.5 alarmCRT
34Channel 1 - Air rotary/damper actuator: {{0}}Sensor value (voltage)2 Bytes9.20 voltage (mV)CRT
34Channel 1 - Air rotary/damper actuator: {{0}}Sensor value (percent)1 Byte5.1 percentage (0..100%)CRT
34Channel 1 - Air rotary/damper actuator: {{0}}Sensor value (resistance)4 Bytes14.60 resistance (Ω)CRT
34Channel 1 - Air rotary/damper actuator: {{0}}Sensor value (switch)1 Bit1.1 switchCRT
34Channel 1 - Air rotary/damper actuator: {{0}}Sensor value (temperature)2 Bytes9.1 temperature (°C)CRT
34Channel 1 - Air rotary/damper actuator: {{0}}Sensor value (humidity)2 Bytes9.7 humidity (%)CRT
34Channel 1 - Air rotary/damper actuator: {{0}}Sensor value (humidity)1 Byte5.1 percentage (0..100%)CRT
34Channel 1 - Air rotary/damper actuator: {{0}}Sensor value (air quality)2 Bytes9.8 parts/million (ppm)CRT
34Channel 1 - Air rotary/damper actuator: {{0}}Sensor value (dew point alarm)1 Bit1.5 alarmCRT
34Channel 1 - Water rotary actuator: {{0}}Sensor value (voltage)2 Bytes9.20 voltage (mV)CRT
34Channel 1 - Water rotary actuator: {{0}}Sensor value (percent)1 Byte5.1 percentage (0..100%)CRT
34Channel 1 - Water rotary actuator: {{0}}Sensor value (resistance)4 Bytes14.60 resistance (Ω)CRT
34Channel 1 - Water rotary actuator: {{0}}Sensor value (switch)1 Bit1.1 switchCRT
34Channel 1 - Water rotary actuator: {{0}}Sensor value (temperature)2 Bytes9.1 temperature (°C)CRT
34Channel 1 - Water rotary actuator: {{0}}Sensor value (humidity)2 Bytes9.7 humidity (%)CRT
34Channel 1 - Water rotary actuator: {{0}}Sensor value (humidity)1 Byte5.1 percentage (0..100%)CRT
34Channel 1 - Water rotary actuator: {{0}}Sensor value (air quality)2 Bytes9.8 parts/million (ppm)CRT
34Channel 1 - Water rotary actuator: {{0}}Sensor value (dew point alarm)1 Bit1.5 alarmCRT
34Channel 1 - VAV universal controller: {{0}}Gear disengagement active1 Bit1.11 stateCRT
34Channel 1 - Water 2-way valve: {{0}}Status Nominal flow rate4 Bytes14.1201 volume flux for meters (1/ls)CRT
34Channel 1 - Thermal energy meter: {{0}}Status Nominal flow rate4 Bytes14.1201 volume flux for meters (1/ls)CRT
34Channel 1 - Room control unit: {{0}}Binary input1 Bit1.1 switchCRT
35Channel 1 - Air VAV compact controller: {{0}}Error cyclical monitoring1 Bit1.5 alarmCRT
35Channel 1 - Air rotary/damper actuator: {{0}}Error cyclical monitoring1 Bit1.5 alarmCRT
35Channel 1 - Water rotary actuator: {{0}}Error cyclical monitoring1 Bit1.5 alarmCRT
35Channel 1 - VAV universal controller: {{0}}Error1 Bit1.5 alarmCRT
35Channel 1 - Water 2-way valve: {{0}}Status Relative power1 Byte5.1 percentage (0..100%)CRT
35Channel 1 - Water 2-way valve: {{0}}Status Relative power2 Bytes8.10 percentage difference (%)CRT
35Channel 1 - Thermal energy meter: {{0}}Status Relative power1 Byte5.1 percentage (0..100%)CRT
35Channel 1 - Thermal energy meter: {{0}}Status Relative power2 Bytes8.10 percentage difference (%)CRT
35Channel 1 - Room control unit: {{0}}Dew point temperature2 Bytes9.1 temperature (°C)CRT
36Channel 1 - Air VAV compact controller: {{0}}Override control active1 Bit1.11 stateCRT
36Channel 1 - Air rotary/damper actuator: {{0}}Override control active1 Bit1.11 stateCRT
36Channel 1 - Water rotary actuator: {{0}}Override control active1 Bit1.11 stateCRT
36Channel 1 - VAV universal controller: {{0}}Error cyclical monitoring1 Bit1.5 alarmCRT
36Channel 1 - Water 2-way valve: {{0}}Status Absolute cooling power4 Bytes14.56 power (W)CRT
36Channel 1 - Thermal energy meter: {{0}}Status Absolute cooling power4 Bytes14.56 power (W)CRT
36Channel 1 - Room control unit: {{0}}Request room temperature setpoint (absolute)2 Bytes9.1 temperature (°C)CT
37Channel 1 - Air VAV compact controller: {{0}}Gear disengagement active1 Bit1.11 stateCRT
37Channel 1 - Air rotary/damper actuator: {{0}}Gear disengagement active1 Bit1.11 stateCRT
37Channel 1 - Water rotary actuator: {{0}}Gear disengagement active1 Bit1.11 stateCRT
37Channel 1 - VAV universal controller: {{0}}Override control active1 Bit1.11 stateCRT
37Channel 1 - Water 2-way valve: {{0}}Status Absolute heating power4 Bytes14.56 power (W)CRT
37Channel 1 - Thermal energy meter: {{0}}Status Absolute heating power4 Bytes14.56 power (W)CRT
37Channel 1 - Room control unit: {{0}}Request room temperature setpoint (relative)2 Bytes9.2 temperature difference (K)CT
38Channel 1 - Air VAV compact controller: {{0}}Error1 Bit1.5 alarmCRT
38Channel 1 - Air rotary/damper actuator: {{0}}Error1 Bit1.5 alarmCRT
38Channel 1 - Water rotary actuator: {{0}}Error1 Bit1.5 alarmCRT
38Channel 1 - VAV universal controller: {{0}}Service information4 Bytes27.1 bit-combined info on/offCRT
38Channel 1 - Water 2-way valve: {{0}}Status Maximum power limit1 Byte5.1 percentage (0..100%)CRT
38Channel 1 - Thermal energy meter: {{0}}Status Maximum power limit1 Byte5.1 percentage (0..100%)CRT
38Channel 1 - Room control unit: {{0}}Request fan speed1 Byte5.1 percentage (0..100%)CT
39Channel 1 - Air VAV compact controller: {{0}}Service information4 Bytes27.1 bit-combined info on/offCRT
39Channel 1 - Air rotary/damper actuator: {{0}}Service information4 Bytes27.1 bit-combined info on/offCRT
39Channel 1 - Water rotary actuator: {{0}}Service information4 Bytes27.1 bit-combined info on/offCRT
39Channel 1 - VAV universal controller: {{0}}Communication error1 Bit1.5 alarmCRT
39Channel 1 - Water 2-way valve: {{0}}Status Nominal power4 Bytes14.56 power (W)CRT
39Channel 1 - Thermal energy meter: {{0}}Status Nominal power4 Bytes14.56 power (W)CRT
39Channel 1 - Room control unit: {{0}}Confirm fan automatic mode1 Bit1.3 enableCT
40Channel 1 - Air VAV compact controller: {{0}}Reset service information1 Bit1.10 start/stopCW
40Channel 1 - Air rotary/damper actuator: {{0}}Reset service information1 Bit1.10 start/stopCW
40Channel 1 - Water rotary actuator: {{0}}Reset service information1 Bit1.10 start/stopCW
40Channel 1 - VAV universal controller: {{0}}Addressing error1 Bit1.5 alarmCRT
40Channel 1 - Water 2-way valve: {{0}}Status Relative differential pressure1 Byte5.1 percentage (0..100%)CRT
40Channel 1 - Room control unit: {{0}}Request RTR operating mode1 Byte20.102 HVAC modeCT
41Channel 1 - Air VAV compact controller: {{0}}Communication error1 Bit1.5 alarmCRT
41Channel 1 - Air rotary/damper actuator: {{0}}Communication error1 Bit1.5 alarmCRT
41Channel 1 - Water rotary actuator: {{0}}Communication error1 Bit1.5 alarmCRT
41Channel 1 - VAV universal controller: {{0}}Configuration error1 Bit1.5 alarmCRT
41Channel 1 - Water 2-way valve: {{0}}Status Absolute differential pressure4 Bytes14.58 pressure (Pa)CRT
41Channel 1 - Room control unit: {{0}}Activate Boost mode1 Bit1.1 switchCT
42Channel 1 - Air VAV compact controller: {{0}}Addressing error1 Bit1.5 alarmCRT
42Channel 1 - Air rotary/damper actuator: {{0}}Addressing error1 Bit1.5 alarmCRT
42Channel 1 - Water rotary actuator: {{0}}Addressing error1 Bit1.5 alarmCRT
42Channel 1 - VAV universal controller: {{0}}MP-Bus address1 Byte5.10 counter pulses (0..255)CRT
42Channel 1 - Water 2-way valve: {{0}}Status Nominal differential pressure4 Bytes14.58 pressure (Pa)CRT
42Channel 1 - Room control unit: {{0}}Service information4 Bytes27.1 bit-combined info on/offCRT
43Channel 1 - Air VAV compact controller: {{0}}Configuration error1 Bit1.5 alarmCRT
43Channel 1 - Air rotary/damper actuator: {{0}}Configuration error1 Bit1.5 alarmCRT
43Channel 1 - Water rotary actuator: {{0}}Configuration error1 Bit1.5 alarmCRT
43Channel 1 - Water 2-way valve: {{0}}Status Glycol concentration2 Bytes8.10 percentage difference (%)CRT
43Channel 1 - Thermal energy meter: {{0}}Status Glycol concentration2 Bytes8.10 percentage difference (%)CRT
43Channel 1 - Room control unit: {{0}}Communication error1 Bit1.5 alarmCRT
44Channel 1 - Air VAV compact controller: {{0}}MP-Bus address1 Byte5.10 counter pulses (0..255)CRT
44Channel 1 - Air rotary/damper actuator: {{0}}MP-Bus address1 Byte5.10 counter pulses (0..255)CRT
44Channel 1 - Water rotary actuator: {{0}}MP-Bus address1 Byte5.10 counter pulses (0..255)CRT
44Channel 1 - Water 2-way valve: {{0}}Certified meter1 Bit1.2 booleanCRT
44Channel 1 - Thermal energy meter: {{0}}Certified meter1 Bit1.2 booleanCRT
44Channel 1 - Room control unit: {{0}}Addressing error1 Bit1.5 alarmCRT
45Channel 1 - Water 2-way valve: {{0}}Status Accumulated volume4 Bytes14.76 volume (m³)CRT
45Channel 1 - Thermal energy meter: {{0}}Status Accumulated volume4 Bytes14.76 volume (m³)CRT
45Channel 1 - Room control unit: {{0}}Configuration error1 Bit1.5 alarmCRT
46Channel 1 - Water 2-way valve: {{0}}Status Total energy cooling4 Bytes13.13 active energy (kWh)CRT
46Channel 1 - Thermal energy meter: {{0}}Status Total energy cooling4 Bytes13.13 active energy (kWh)CRT
46Channel 1 - Room control unit: {{0}}MP-Bus address1 Byte5.10 counter pulses (0..255)CRT
47Channel 1 - Water 2-way valve: {{0}}Status Total energy heating4 Bytes13.13 active energy (kWh)CRT
47Channel 1 - Thermal energy meter: {{0}}Status Total energy heating4 Bytes13.13 active energy (kWh)CRT
48Channel 1 - Water 2-way valve: {{0}}Energy meter serial number (upper digits)4 BytesCRT
48Channel 1 - Thermal energy meter: {{0}}Energy meter serial number (upper digits)4 BytesCRT
49Channel 1 - Water 2-way valve: {{0}}Energy meter serial number (lower digits)4 BytesCRT
49Channel 1 - Thermal energy meter: {{0}}Energy meter serial number (lower digits)4 BytesCRT
50Channel 1 - Water 2-way valve: {{0}}Status Delta temperature2 Bytes9.2 temperature difference (K)CRT
50Channel 1 - Thermal energy meter: {{0}}Status Delta temperature2 Bytes9.2 temperature difference (K)CRT
51Channel 1 - Water 2-way valve: {{0}}Status Delta-T Manager1 Bit1.2 booleanCRT
51Channel 1 - Thermal energy meter: {{0}}Status Delta-T Manager1 Bit1.2 booleanCRT
52Channel 1 - Water 2-way valve: {{0}}Status Delta-T Manager flow-dependent adjustment (scaling)1 Bit1.2 booleanCRT
52Channel 1 - Thermal energy meter: {{0}}Status Delta-T Manager flow-dependent adjustment (scaling)1 Bit1.2 booleanCRT
53Channel 1 - Water 2-way valve: {{0}}Temperature internal sensor2 Bytes9.1 temperature (°C)CRT
53Channel 1 - Thermal energy meter: {{0}}Temperature internal sensor2 Bytes9.1 temperature (°C)CRT
54Channel 1 - Water 2-way valve: {{0}}Temperature external sensor2 Bytes9.1 temperature (°C)CRT
54Channel 1 - Thermal energy meter: {{0}}Temperature external sensor2 Bytes9.1 temperature (°C)CRT
55Channel 1 - Water 2-way valve: {{0}}Sensor value (voltage)2 Bytes9.20 voltage (mV)CRT
55Channel 1 - Water 2-way valve: {{0}}Sensor value (percent)1 Byte5.1 percentage (0..100%)CRT
55Channel 1 - Water 2-way valve: {{0}}Sensor value (resistance)4 Bytes14.60 resistance (Ω)CRT
55Channel 1 - Water 2-way valve: {{0}}Sensor value (temperature)2 Bytes9.1 temperature (°C)CRT
55Channel 1 - Water 2-way valve: {{0}}Sensor value (switch)1 Bit1.1 switchCRT
55Channel 1 - Water 2-way valve: {{0}}Sensor value (air quality)2 Bytes9.8 parts/million (ppm)CRT
55Channel 1 - Water 2-way valve: {{0}}Sensor value (dew point alarm)1 Bit1.5 alarmCRT
55Channel 1 - Water 2-way valve: {{0}}Sensor value (humidity)2 Bytes9.7 humidity (%)CRT
55Channel 1 - Water 2-way valve: {{0}}Sensor value (humidity)1 Byte5.1 percentage (0..100%)CRT
55Channel 1 - Thermal energy meter: {{0}}Sensor value (voltage)2 Bytes9.20 voltage (mV)CRT
55Channel 1 - Thermal energy meter: {{0}}Sensor value (percent)1 Byte5.1 percentage (0..100%)CRT
55Channel 1 - Thermal energy meter: {{0}}Sensor value (resistance)4 Bytes14.60 resistance (Ω)CRT
55Channel 1 - Thermal energy meter: {{0}}Sensor value (temperature)2 Bytes9.1 temperature (°C)CRT
55Channel 1 - Thermal energy meter: {{0}}Sensor value (switch)1 Bit1.1 switchCRT
55Channel 1 - Thermal energy meter: {{0}}Sensor value (air quality)2 Bytes9.8 parts/million (ppm)CRT
55Channel 1 - Thermal energy meter: {{0}}Sensor value (dew point alarm)1 Bit1.5 alarmCRT
55Channel 1 - Thermal energy meter: {{0}}Sensor value (humidity)2 Bytes9.7 humidity (%)CRT
55Channel 1 - Thermal energy meter: {{0}}Sensor value (humidity)1 Byte5.1 percentage (0..100%)CRT
56Channel 1 - Water 2-way valve: {{0}}Error cyclical monitoring1 Bit1.5 alarmCRT
56Channel 1 - Thermal energy meter: {{0}}Error cyclical monitoring1 Bit1.5 alarmCRT
57Channel 1 - Water 2-way valve: {{0}}Override control active1 Bit1.11 stateCRT
57Channel 1 - Thermal energy meter: {{0}}Override control active1 Bit1.11 stateCRT
58Channel 1 - Water 2-way valve: {{0}}Gear disengagement active1 Bit1.11 stateCRT
58Channel 1 - Thermal energy meter: {{0}}Gear disengagement active1 Bit1.11 stateCRT
59Channel 1 - Water 2-way valve: {{0}}Error1 Bit1.5 alarmCRT
59Channel 1 - Thermal energy meter: {{0}}Error1 Bit1.5 alarmCRT
60Channel 1 - Water 2-way valve: {{0}}Sensor module must be replaced1 Bit1.5 alarmCRT
60Channel 1 - Thermal energy meter: {{0}}Sensor module must be replaced1 Bit1.5 alarmCRT
61Channel 1 - Water 2-way valve: {{0}}MP-Bus monitoring timed out1 Bit1.5 alarmCRT
61Channel 1 - Thermal energy meter: {{0}}MP-Bus monitoring timed out1 Bit1.5 alarmCRT
62Channel 1 - Water 2-way valve: {{0}}Service information4 Bytes27.1 bit-combined info on/offCRT
62Channel 1 - Thermal energy meter: {{0}}Service information4 Bytes27.1 bit-combined info on/offCRT
63Channel 1 - Water 2-way valve: {{0}}Communication error1 Bit1.5 alarmCRT
63Channel 1 - Thermal energy meter: {{0}}Communication error1 Bit1.5 alarmCRT
64Channel 1 - Water 2-way valve: {{0}}Addressing error1 Bit1.5 alarmCRT
64Channel 1 - Thermal energy meter: {{0}}Addressing error1 Bit1.5 alarmCRT
65Channel 1 - Water 2-way valve: {{0}}Configuration error1 Bit1.5 alarmCRT
65Channel 1 - Thermal energy meter: {{0}}Configuration error1 Bit1.5 alarmCRT
66Channel 1 - Water 2-way valve: {{0}}MP-Bus address1 Byte5.10 counter pulses (0..255)CRT
66Channel 1 - Thermal energy meter: {{0}}MP-Bus address1 Byte5.10 counter pulses (0..255)CRT
67Channel 2 - Air VAV compact controller: {{0}}Setpoint1 Byte5.1 percentage (0..100%)CWTUI
67Channel 2 - Air VAV compact controller: {{0}}Control value1 Byte5.1 percentage (0..100%)CWTUI
67Channel 2 - Air VAV compact controller: {{0}}Heating control value1 Byte5.1 percentage (0..100%)CWTUI
67Channel 2 - Air rotary/damper actuator: {{0}}Setpoint1 Byte5.1 percentage (0..100%)CWTUI
67Channel 2 - Air rotary/damper actuator: {{0}}Control value1 Byte5.1 percentage (0..100%)CWTUI
67Channel 2 - Air rotary/damper actuator: {{0}}Heating control value1 Byte5.1 percentage (0..100%)CWTUI
67Channel 2 - Water rotary actuator: {{0}}Setpoint1 Byte5.1 percentage (0..100%)CWTUI
67Channel 2 - Water rotary actuator: {{0}}Control value1 Byte5.1 percentage (0..100%)CWTUI
67Channel 2 - Water rotary actuator: {{0}}Heating control value1 Byte5.1 percentage (0..100%)CWTUI
67Channel 2 - VAV universal controller: {{0}}Setpoint1 Byte5.1 percentage (0..100%)CWTUI
67Channel 2 - Water 2-way valve: {{0}}Setpoint1 Byte5.1 percentage (0..100%)CWTUI
67Channel 2 - Thermal energy meter: {{0}}Setpoint1 Byte5.1 percentage (0..100%)CWTUI
67Channel 2 - Room control unit: {{0}}Confirm room temperature setpoint (absolute)2 Bytes9.1 temperature (°C)CWTUI
67Channel 2 - Room control unit: {{0}}Confirm room temperature setpoint (relative)2 Bytes9.2 temperature difference (K)CWTUI
68Channel 2 - Air VAV compact controller: {{0}}Cooling control value1 Byte5.1 percentage (0..100%)CWTUI
68Channel 2 - Air rotary/damper actuator: {{0}}Cooling control value1 Byte5.1 percentage (0..100%)CWTUI
68Channel 2 - Water rotary actuator: {{0}}Cooling control value1 Byte5.1 percentage (0..100%)CWTUI
68Channel 2 - VAV universal controller: {{0}}Override control1 ByteCWTUI
68Channel 2 - Water 2-way valve: {{0}}Setpoint absolute differential pressure4 Bytes14.58 pressure (Pa)CWTUI
68Channel 2 - Thermal energy meter: {{0}}Setpoint absolute differential pressure4 Bytes14.58 pressure (Pa)CWTUI
68Channel 2 - Room control unit: {{0}}Basic setpoint2 Bytes9.1 temperature (°C)CWTUI
69Channel 2 - Air VAV compact controller: {{0}}Heating/cooling changeover1 Bit1.100 cooling/heatingCWTUI
69Channel 2 - Air rotary/damper actuator: {{0}}Heating/cooling changeover1 Bit1.100 cooling/heatingCWTUI
69Channel 2 - Water rotary actuator: {{0}}Heating/cooling changeover1 Bit1.100 cooling/heatingCWTUI
69Channel 2 - VAV universal controller: {{0}}Start adjustment1 Bit1.17 triggerCW
69Channel 2 - Water 2-way valve: {{0}}Minimum flow rate1 Byte5.1 percentage (0..100%)CWTUI
69Channel 2 - Thermal energy meter: {{0}}Minimum flow rate1 Byte5.1 percentage (0..100%)CWTUI
69Channel 2 - Room control unit: {{0}}Confirm fan speed1 Byte5.1 percentage (0..100%)CWTUI
70Channel 2 - Air VAV compact controller: {{0}}Activate heating1 Bit1.3 enableCWTUI
70Channel 2 - Air rotary/damper actuator: {{0}}Activate heating1 Bit1.3 enableCWTUI
70Channel 2 - Water rotary actuator: {{0}}Activate heating1 Bit1.3 enableCWTUI
70Channel 2 - VAV universal controller: {{0}}Start synchronization1 Bit1.17 triggerCW
70Channel 2 - Water 2-way valve: {{0}}Maximum flow rate1 Byte5.1 percentage (0..100%)CWTUI
70Channel 2 - Thermal energy meter: {{0}}Maximum flow rate1 Byte5.1 percentage (0..100%)CWTUI
70Channel 2 - Room control unit: {{0}}Request fan automatic mode1 Bit1.3 enableCWTUI
71Channel 2 - Air VAV compact controller: {{0}}Activate cooling1 Bit1.3 enableCWTUI
71Channel 2 - Air rotary/damper actuator: {{0}}Activate cooling1 Bit1.3 enableCWTUI
71Channel 2 - Water rotary actuator: {{0}}Activate cooling1 Bit1.3 enableCWTUI
71Channel 2 - VAV universal controller: {{0}}Minimum flow rate1 Byte5.1 percentage (0..100%)CWTUI
71Channel 2 - VAV universal controller: {{0}}Minimum differential pressure1 Byte5.1 percentage (0..100%)CWTUI
71Channel 2 - Water 2-way valve: {{0}}Maximum power limit1 Byte5.1 percentage (0..100%)CWTUI
71Channel 2 - Thermal energy meter: {{0}}Maximum power limit1 Byte5.1 percentage (0..100%)CWTUI
71Channel 2 - Room control unit: {{0}}Display warning icon1 Bit1.3 enableCWTUI
72Channel 2 - Air VAV compact controller: {{0}}Override control1 ByteCWTUI
72Channel 2 - Air rotary/damper actuator: {{0}}Override control1 ByteCWTUI
72Channel 2 - Water rotary actuator: {{0}}Override control1 ByteCWTUI
72Channel 2 - VAV universal controller: {{0}}Maximum flow rate1 Byte5.1 percentage (0..100%)CWTUI
72Channel 2 - VAV universal controller: {{0}}Maximum differential pressure1 Byte5.1 percentage (0..100%)CWTUI
72Channel 2 - Water 2-way valve: {{0}}Activate Delta-T Manager1 Bit1.3 enableCWTUI
72Channel 2 - Thermal energy meter: {{0}}Activate Delta-T Manager1 Bit1.3 enableCWTUI
72Channel 2 - Room control unit: {{0}}Display window icon1 Bit1.3 enableCWTUI
73Channel 2 - Air VAV compact controller: {{0}}Minimum position1 Byte5.1 percentage (0..100%)CWTUI
73Channel 2 - Air VAV compact controller: {{0}}Minimum flow rate1 Byte5.1 percentage (0..100%)CWTUI
73Channel 2 - Air rotary/damper actuator: {{0}}Minimum position1 Byte5.1 percentage (0..100%)CWTUI
73Channel 2 - Air rotary/damper actuator: {{0}}Minimum flow rate1 Byte5.1 percentage (0..100%)CWTUI
73Channel 2 - Water rotary actuator: {{0}}Minimum position1 Byte5.1 percentage (0..100%)CWTUI
73Channel 2 - Water rotary actuator: {{0}}Minimum flow rate1 Byte5.1 percentage (0..100%)CWTUI
73Channel 2 - VAV universal controller: {{0}}Status Analog input signal1 Byte5.1 percentage (0..100%)CRT
73Channel 2 - Water 2-way valve: {{0}}Activate Delta-T Manager flow-dependent adjustment (scaling)1 Bit1.3 enableCWTUI
73Channel 2 - Thermal energy meter: {{0}}Activate Delta-T Manager flow-dependent adjustment (scaling)1 Bit1.3 enableCWTUI
73Channel 2 - Room control unit: {{0}}Status RTC controller2 Bytes22.103 combined status RTCCWTUI
74Channel 2 - Air VAV compact controller: {{0}}Maximum position1 Byte5.1 percentage (0..100%)CWTUI
74Channel 2 - Air VAV compact controller: {{0}}Maximum flow rate1 Byte5.1 percentage (0..100%)CWTUI
74Channel 2 - Air rotary/damper actuator: {{0}}Maximum position1 Byte5.1 percentage (0..100%)CWTUI
74Channel 2 - Air rotary/damper actuator: {{0}}Maximum flow rate1 Byte5.1 percentage (0..100%)CWTUI
74Channel 2 - Water rotary actuator: {{0}}Maximum position1 Byte5.1 percentage (0..100%)CWTUI
74Channel 2 - Water rotary actuator: {{0}}Maximum flow rate1 Byte5.1 percentage (0..100%)CWTUI
74Channel 2 - VAV universal controller: {{0}}Status Relative position1 Byte5.1 percentage (0..100%)CRT
74Channel 2 - Water 2-way valve: {{0}}Setpoint Delta-T limitation2 Bytes9.2 temperature difference (K)CWTUI
74Channel 2 - Thermal energy meter: {{0}}Setpoint Delta-T limitation2 Bytes9.2 temperature difference (K)CWTUI
74Channel 2 - Room control unit: {{0}}Receive status Heating1 Bit1.3 enableCWTUI
75Channel 2 - Air VAV compact controller: {{0}}Start test run1 Bit1.17 triggerCW
75Channel 2 - Air rotary/damper actuator: {{0}}Start test run1 Bit1.17 triggerCW
75Channel 2 - Water rotary actuator: {{0}}Start test run1 Bit1.17 triggerCW
75Channel 2 - VAV universal controller: {{0}}Status Absolute position2 Bytes8.11 rotation angle (°)CRT
75Channel 2 - Water 2-way valve: {{0}}Setpoint absolute flow at Delta-T4 Bytes14.1201 volume flux for meters (1/ls)CWTUI
75Channel 2 - Thermal energy meter: {{0}}Setpoint absolute flow at Delta-T4 Bytes14.1201 volume flux for meters (1/ls)CWTUI
75Channel 2 - Room control unit: {{0}}Receive status Cooling1 Bit1.3 enableCWTUI
76Channel 2 - Air VAV compact controller: {{0}}Start adjustment1 Bit1.17 triggerCW
76Channel 2 - Air rotary/damper actuator: {{0}}Start adjustment1 Bit1.17 triggerCW
76Channel 2 - Water rotary actuator: {{0}}Start adjustment1 Bit1.17 triggerCW
76Channel 2 - VAV universal controller: {{0}}Status Minimum flow rate1 Byte5.1 percentage (0..100%)CRT
76Channel 2 - VAV universal controller: {{0}}Status Minimum differential pressure1 Byte5.1 percentage (0..100%)CRT
76Channel 2 - Water 2-way valve: {{0}}Start synchronization1 Bit1.17 triggerCW
76Channel 2 - Thermal energy meter: {{0}}Start synchronization1 Bit1.17 triggerCW
76Channel 2 - Room control unit: {{0}}Confirm RTR operating mode1 Byte20.102 HVAC modeCWTUI
77Channel 2 - Air VAV compact controller: {{0}}Status Relative position1 Byte5.1 percentage (0..100%)CRT
77Channel 2 - Air rotary/damper actuator: {{0}}Status Relative position1 Byte5.1 percentage (0..100%)CRT
77Channel 2 - Water rotary actuator: {{0}}Status Relative position1 Byte5.1 percentage (0..100%)CRT
77Channel 2 - VAV universal controller: {{0}}Status Maximum flow rate1 Byte5.1 percentage (0..100%)CRT
77Channel 2 - VAV universal controller: {{0}}Status Maximum differential pressure1 Byte5.1 percentage (0..100%)CRT
77Channel 2 - Water 2-way valve: {{0}}Override control1 ByteCWTUI
77Channel 2 - Thermal energy meter: {{0}}Override control1 ByteCWTUI
77Channel 2 - Room control unit: {{0}}Block local operation1 Bit1.3 enableCWTUI
78Channel 2 - Air VAV compact controller: {{0}}Status Absolute position (rotation angle)2 Bytes8.11 rotation angle (°)CRT
78Channel 2 - Air VAV compact controller: {{0}}Status Absolute position (millimeters)2 Bytes7.11 length (mm)CRT
78Channel 2 - Air rotary/damper actuator: {{0}}Status Absolute position (rotation angle)2 Bytes8.11 rotation angle (°)CRT
78Channel 2 - Air rotary/damper actuator: {{0}}Status Absolute position (millimeters)2 Bytes7.11 length (mm)CRT
78Channel 2 - Water rotary actuator: {{0}}Status Absolute position (rotation angle)2 Bytes8.11 rotation angle (°)CRT
78Channel 2 - Water rotary actuator: {{0}}Status Absolute position (millimeters)2 Bytes7.11 length (mm)CRT
78Channel 2 - VAV universal controller: {{0}}Status Relative flow rate1 Byte5.1 percentage (0..100%)CRT
78Channel 2 - Water 2-way valve: {{0}}Status Analog input signal1 Byte5.1 percentage (0..100%)CRT
78Channel 2 - Thermal energy meter: {{0}}Status Analog input signal1 Byte5.1 percentage (0..100%)CRT
78Channel 2 - Room control unit: {{0}}Display Boost mode1 Bit1.1 switchCWTUI
79Channel 2 - Air VAV compact controller: {{0}}Status Nominal range (rotation angle)2 Bytes8.11 rotation angle (°)CRT
79Channel 2 - Air VAV compact controller: {{0}}Status Nominal range (millimeters)2 Bytes7.11 length (mm)CRT
79Channel 2 - Air rotary/damper actuator: {{0}}Status Nominal range (rotation angle)2 Bytes8.11 rotation angle (°)CRT
79Channel 2 - Air rotary/damper actuator: {{0}}Status Nominal range (millimeters)2 Bytes7.11 length (mm)CRT
79Channel 2 - Water rotary actuator: {{0}}Status Nominal range (rotation angle)2 Bytes8.11 rotation angle (°)CRT
79Channel 2 - Water rotary actuator: {{0}}Status Nominal range (millimeters)2 Bytes7.11 length (mm)CRT
79Channel 2 - VAV universal controller: {{0}}Status Absolute flow rate4 Bytes14.77 volume flux (m³/s)CRT
79Channel 2 - VAV universal controller: {{0}}Status Absolute flow rate2 Bytes9.9 air flow (m³/h)CRT
79Channel 2 - Water 2-way valve: {{0}}Status Relative position1 Byte5.1 percentage (0..100%)CRT
79Channel 2 - Thermal energy meter: {{0}}Status Relative position1 Byte5.1 percentage (0..100%)CRT
79Channel 2 - Room control unit: {{0}}Status Room temperature2 Bytes9.1 temperature (°C)CRT
80Channel 2 - Air VAV compact controller: {{0}}Status Relative flow rate1 Byte5.1 percentage (0..100%)CRT
80Channel 2 - Air rotary/damper actuator: {{0}}Status Relative flow rate1 Byte5.1 percentage (0..100%)CRT
80Channel 2 - Water rotary actuator: {{0}}Status Relative flow rate1 Byte5.1 percentage (0..100%)CRT
80Channel 2 - VAV universal controller: {{0}}Status Nominal flow rate4 Bytes14.77 volume flux (m³/s)CRT
80Channel 2 - VAV universal controller: {{0}}Status Nominal flow rate2 Bytes9.9 air flow (m³/h)CRT
80Channel 2 - Water 2-way valve: {{0}}Status Absolute position2 Bytes8.11 rotation angle (°)CRT
80Channel 2 - Thermal energy meter: {{0}}Status Absolute position2 Bytes8.11 rotation angle (°)CRT
80Channel 2 - Room control unit: {{0}}Status Relative humidity1 Byte5.1 percentage (0..100%)CRT
81Channel 2 - Air VAV compact controller: {{0}}Status Absolute flow rate4 Bytes14.77 volume flux (m³/s)CRT
81Channel 2 - Air VAV compact controller: {{0}}Status Absolute flow rate2 Bytes9.9 air flow (m³/h)CRT
81Channel 2 - Air rotary/damper actuator: {{0}}Status Absolute flow rate4 Bytes14.77 volume flux (m³/s)CRT
81Channel 2 - Air rotary/damper actuator: {{0}}Status Absolute flow rate2 Bytes9.9 air flow (m³/h)CRT
81Channel 2 - Water rotary actuator: {{0}}Status Absolute flow rate4 Bytes14.77 volume flux (m³/s)CRT
81Channel 2 - Water rotary actuator: {{0}}Status Absolute flow rate2 Bytes9.9 air flow (m³/h)CRT
81Channel 2 - VAV universal controller: {{0}}Status Relative differential pressure2 Bytes8.10 percentage difference (%)CRT
81Channel 2 - Water 2-way valve: {{0}}Status Relative flow rate1 Byte5.1 percentage (0..100%)CRT
81Channel 2 - Water 2-way valve: {{0}}Status Relative flow rate2 Bytes8.10 percentage difference (%)CRT
81Channel 2 - Thermal energy meter: {{0}}Status Relative flow rate1 Byte5.1 percentage (0..100%)CRT
81Channel 2 - Thermal energy meter: {{0}}Status Relative flow rate2 Bytes8.10 percentage difference (%)CRT
81Channel 2 - Room control unit: {{0}}CO2 value2 Bytes9.8 parts/million (ppm)CRT
82Channel 2 - Air VAV compact controller: {{0}}Status Nominal flow rate4 Bytes14.77 volume flux (m³/s)CRT
82Channel 2 - Air VAV compact controller: {{0}}Status Nominal flow rate2 Bytes9.9 air flow (m³/h)CRT
82Channel 2 - Air rotary/damper actuator: {{0}}Status Nominal flow rate4 Bytes14.77 volume flux (m³/s)CRT
82Channel 2 - Air rotary/damper actuator: {{0}}Status Nominal flow rate2 Bytes9.9 air flow (m³/h)CRT
82Channel 2 - Water rotary actuator: {{0}}Status Nominal flow rate4 Bytes14.77 volume flux (m³/s)CRT
82Channel 2 - Water rotary actuator: {{0}}Status Nominal flow rate2 Bytes9.9 air flow (m³/h)CRT
82Channel 2 - VAV universal controller: {{0}}Status Absolute differential pressure4 Bytes14.58 pressure (Pa)CRT
82Channel 2 - Water 2-way valve: {{0}}Status Absolute flow rate4 Bytes14.1201 volume flux for meters (1/ls)CRT
82Channel 2 - Thermal energy meter: {{0}}Status Absolute flow rate4 Bytes14.1201 volume flux for meters (1/ls)CRT
82Channel 2 - Room control unit: {{0}}Air quality OK1 Bit1.2 booleanCRT
83Channel 2 - Air VAV compact controller: {{0}}Status Minimum position1 Byte5.1 percentage (0..100%)CRT
83Channel 2 - Air VAV compact controller: {{0}}Status Minimum flow rate1 Byte5.1 percentage (0..100%)CRT
83Channel 2 - Air rotary/damper actuator: {{0}}Status Minimum position1 Byte5.1 percentage (0..100%)CRT
83Channel 2 - Air rotary/damper actuator: {{0}}Status Minimum flow rate1 Byte5.1 percentage (0..100%)CRT
83Channel 2 - Water rotary actuator: {{0}}Status Minimum position1 Byte5.1 percentage (0..100%)CRT
83Channel 2 - Water rotary actuator: {{0}}Status Minimum flow rate1 Byte5.1 percentage (0..100%)CRT
83Channel 2 - VAV universal controller: {{0}}Status Nominal differential pressure4 Bytes14.58 pressure (Pa)CRT
83Channel 2 - Water 2-way valve: {{0}}Status Minimum flow rate1 Byte5.1 percentage (0..100%)CRT
83Channel 2 - Thermal energy meter: {{0}}Status Minimum flow rate1 Byte5.1 percentage (0..100%)CRT
83Channel 2 - Room control unit: {{0}}Air quality warning1 Bit1.2 booleanCRT
84Channel 2 - Air VAV compact controller: {{0}}Status Maximum position1 Byte5.1 percentage (0..100%)CRT
84Channel 2 - Air VAV compact controller: {{0}}Status Maximum flow rate1 Byte5.1 percentage (0..100%)CRT
84Channel 2 - Air rotary/damper actuator: {{0}}Status Maximum position1 Byte5.1 percentage (0..100%)CRT
84Channel 2 - Air rotary/damper actuator: {{0}}Status Maximum flow rate1 Byte5.1 percentage (0..100%)CRT
84Channel 2 - Water rotary actuator: {{0}}Status Maximum position1 Byte5.1 percentage (0..100%)CRT
84Channel 2 - Water rotary actuator: {{0}}Status Maximum flow rate1 Byte5.1 percentage (0..100%)CRT
84Channel 2 - VAV universal controller: {{0}}Sensor value (voltage)2 Bytes9.20 voltage (mV)CRT
84Channel 2 - VAV universal controller: {{0}}Sensor value (percent)1 Byte5.1 percentage (0..100%)CRT
84Channel 2 - VAV universal controller: {{0}}Sensor value (resistance)4 Bytes14.60 resistance (Ω)CRT
84Channel 2 - VAV universal controller: {{0}}Sensor value (switch)1 Bit1.1 switchCRT
84Channel 2 - VAV universal controller: {{0}}Sensor value (temperature)2 Bytes9.1 temperature (°C)CRT
84Channel 2 - VAV universal controller: {{0}}Sensor value (humidity)2 Bytes9.7 humidity (%)CRT
84Channel 2 - VAV universal controller: {{0}}Sensor value (humidity)1 Byte5.1 percentage (0..100%)CRT
84Channel 2 - VAV universal controller: {{0}}Sensor value (air quality)2 Bytes9.8 parts/million (ppm)CRT
84Channel 2 - VAV universal controller: {{0}}Sensor value (dew point alarm)1 Bit1.5 alarmCRT
84Channel 2 - Water 2-way valve: {{0}}Status Maximum flow rate1 Byte5.1 percentage (0..100%)CRT
84Channel 2 - Thermal energy meter: {{0}}Status Maximum flow rate1 Byte5.1 percentage (0..100%)CRT
84Channel 2 - Room control unit: {{0}}Air quality alarm1 Bit1.2 booleanCRT
85Channel 2 - Air VAV compact controller: {{0}}Sensor value (voltage)2 Bytes9.20 voltage (mV)CRT
85Channel 2 - Air VAV compact controller: {{0}}Sensor value (percent)1 Byte5.1 percentage (0..100%)CRT
85Channel 2 - Air VAV compact controller: {{0}}Sensor value (resistance)4 Bytes14.60 resistance (Ω)CRT
85Channel 2 - Air VAV compact controller: {{0}}Sensor value (switch)1 Bit1.1 switchCRT
85Channel 2 - Air VAV compact controller: {{0}}Sensor value (temperature)2 Bytes9.1 temperature (°C)CRT
85Channel 2 - Air VAV compact controller: {{0}}Sensor value (humidity)2 Bytes9.7 humidity (%)CRT
85Channel 2 - Air VAV compact controller: {{0}}Sensor value (humidity)1 Byte5.1 percentage (0..100%)CRT
85Channel 2 - Air VAV compact controller: {{0}}Sensor value (air quality)2 Bytes9.8 parts/million (ppm)CRT
85Channel 2 - Air VAV compact controller: {{0}}Sensor value (dew point alarm)1 Bit1.5 alarmCRT
85Channel 2 - Air rotary/damper actuator: {{0}}Sensor value (voltage)2 Bytes9.20 voltage (mV)CRT
85Channel 2 - Air rotary/damper actuator: {{0}}Sensor value (percent)1 Byte5.1 percentage (0..100%)CRT
85Channel 2 - Air rotary/damper actuator: {{0}}Sensor value (resistance)4 Bytes14.60 resistance (Ω)CRT
85Channel 2 - Air rotary/damper actuator: {{0}}Sensor value (switch)1 Bit1.1 switchCRT
85Channel 2 - Air rotary/damper actuator: {{0}}Sensor value (temperature)2 Bytes9.1 temperature (°C)CRT
85Channel 2 - Air rotary/damper actuator: {{0}}Sensor value (humidity)2 Bytes9.7 humidity (%)CRT
85Channel 2 - Air rotary/damper actuator: {{0}}Sensor value (humidity)1 Byte5.1 percentage (0..100%)CRT
85Channel 2 - Air rotary/damper actuator: {{0}}Sensor value (air quality)2 Bytes9.8 parts/million (ppm)CRT
85Channel 2 - Air rotary/damper actuator: {{0}}Sensor value (dew point alarm)1 Bit1.5 alarmCRT
85Channel 2 - Water rotary actuator: {{0}}Sensor value (voltage)2 Bytes9.20 voltage (mV)CRT
85Channel 2 - Water rotary actuator: {{0}}Sensor value (percent)1 Byte5.1 percentage (0..100%)CRT
85Channel 2 - Water rotary actuator: {{0}}Sensor value (resistance)4 Bytes14.60 resistance (Ω)CRT
85Channel 2 - Water rotary actuator: {{0}}Sensor value (switch)1 Bit1.1 switchCRT
85Channel 2 - Water rotary actuator: {{0}}Sensor value (temperature)2 Bytes9.1 temperature (°C)CRT
85Channel 2 - Water rotary actuator: {{0}}Sensor value (humidity)2 Bytes9.7 humidity (%)CRT
85Channel 2 - Water rotary actuator: {{0}}Sensor value (humidity)1 Byte5.1 percentage (0..100%)CRT
85Channel 2 - Water rotary actuator: {{0}}Sensor value (air quality)2 Bytes9.8 parts/million (ppm)CRT
85Channel 2 - Water rotary actuator: {{0}}Sensor value (dew point alarm)1 Bit1.5 alarmCRT
85Channel 2 - VAV universal controller: {{0}}Gear disengagement active1 Bit1.11 stateCRT
85Channel 2 - Water 2-way valve: {{0}}Status Nominal flow rate4 Bytes14.1201 volume flux for meters (1/ls)CRT
85Channel 2 - Thermal energy meter: {{0}}Status Nominal flow rate4 Bytes14.1201 volume flux for meters (1/ls)CRT
85Channel 2 - Room control unit: {{0}}Binary input1 Bit1.1 switchCRT
86Channel 2 - Air VAV compact controller: {{0}}Error cyclical monitoring1 Bit1.5 alarmCRT
86Channel 2 - Air rotary/damper actuator: {{0}}Error cyclical monitoring1 Bit1.5 alarmCRT
86Channel 2 - Water rotary actuator: {{0}}Error cyclical monitoring1 Bit1.5 alarmCRT
86Channel 2 - VAV universal controller: {{0}}Error1 Bit1.5 alarmCRT
86Channel 2 - Water 2-way valve: {{0}}Status Relative power1 Byte5.1 percentage (0..100%)CRT
86Channel 2 - Water 2-way valve: {{0}}Status Relative power2 Bytes8.10 percentage difference (%)CRT
86Channel 2 - Thermal energy meter: {{0}}Status Relative power1 Byte5.1 percentage (0..100%)CRT
86Channel 2 - Thermal energy meter: {{0}}Status Relative power2 Bytes8.10 percentage difference (%)CRT
86Channel 2 - Room control unit: {{0}}Dew point temperature2 Bytes9.1 temperature (°C)CRT
87Channel 2 - Air VAV compact controller: {{0}}Override control active1 Bit1.11 stateCRT
87Channel 2 - Air rotary/damper actuator: {{0}}Override control active1 Bit1.11 stateCRT
87Channel 2 - Water rotary actuator: {{0}}Override control active1 Bit1.11 stateCRT
87Channel 2 - VAV universal controller: {{0}}Error cyclical monitoring1 Bit1.5 alarmCRT
87Channel 2 - Water 2-way valve: {{0}}Status Absolute cooling power4 Bytes14.56 power (W)CRT
87Channel 2 - Thermal energy meter: {{0}}Status Absolute cooling power4 Bytes14.56 power (W)CRT
87Channel 2 - Room control unit: {{0}}Request room temperature setpoint (absolute)2 Bytes9.1 temperature (°C)CT
88Channel 2 - Air VAV compact controller: {{0}}Gear disengagement active1 Bit1.11 stateCRT
88Channel 2 - Air rotary/damper actuator: {{0}}Gear disengagement active1 Bit1.11 stateCRT
88Channel 2 - Water rotary actuator: {{0}}Gear disengagement active1 Bit1.11 stateCRT
88Channel 2 - VAV universal controller: {{0}}Override control active1 Bit1.11 stateCRT
88Channel 2 - Water 2-way valve: {{0}}Status Absolute heating power4 Bytes14.56 power (W)CRT
88Channel 2 - Thermal energy meter: {{0}}Status Absolute heating power4 Bytes14.56 power (W)CRT
88Channel 2 - Room control unit: {{0}}Request room temperature setpoint (relative)2 Bytes9.2 temperature difference (K)CT
89Channel 2 - Air VAV compact controller: {{0}}Error1 Bit1.5 alarmCRT
89Channel 2 - Air rotary/damper actuator: {{0}}Error1 Bit1.5 alarmCRT
89Channel 2 - Water rotary actuator: {{0}}Error1 Bit1.5 alarmCRT
89Channel 2 - VAV universal controller: {{0}}Service information4 Bytes27.1 bit-combined info on/offCRT
89Channel 2 - Water 2-way valve: {{0}}Status Maximum power limit1 Byte5.1 percentage (0..100%)CRT
89Channel 2 - Thermal energy meter: {{0}}Status Maximum power limit1 Byte5.1 percentage (0..100%)CRT
89Channel 2 - Room control unit: {{0}}Request fan speed1 Byte5.1 percentage (0..100%)CT
90Channel 2 - Air VAV compact controller: {{0}}Service information4 Bytes27.1 bit-combined info on/offCRT
90Channel 2 - Air rotary/damper actuator: {{0}}Service information4 Bytes27.1 bit-combined info on/offCRT
90Channel 2 - Water rotary actuator: {{0}}Service information4 Bytes27.1 bit-combined info on/offCRT
90Channel 2 - VAV universal controller: {{0}}Communication error1 Bit1.5 alarmCRT
90Channel 2 - Water 2-way valve: {{0}}Status Nominal power4 Bytes14.56 power (W)CRT
90Channel 2 - Thermal energy meter: {{0}}Status Nominal power4 Bytes14.56 power (W)CRT
90Channel 2 - Room control unit: {{0}}Confirm fan automatic mode1 Bit1.3 enableCT
91Channel 2 - Air VAV compact controller: {{0}}Reset service information1 Bit1.10 start/stopCW
91Channel 2 - Air rotary/damper actuator: {{0}}Reset service information1 Bit1.10 start/stopCW
91Channel 2 - Water rotary actuator: {{0}}Reset service information1 Bit1.10 start/stopCW
91Channel 2 - VAV universal controller: {{0}}Addressing error1 Bit1.5 alarmCRT
91Channel 2 - Water 2-way valve: {{0}}Status Relative differential pressure1 Byte5.1 percentage (0..100%)CRT
91Channel 2 - Room control unit: {{0}}Request RTR operating mode1 Byte20.102 HVAC modeCT
92Channel 2 - Air VAV compact controller: {{0}}Communication error1 Bit1.5 alarmCRT
92Channel 2 - Air rotary/damper actuator: {{0}}Communication error1 Bit1.5 alarmCRT
92Channel 2 - Water rotary actuator: {{0}}Communication error1 Bit1.5 alarmCRT
92Channel 2 - VAV universal controller: {{0}}Configuration error1 Bit1.5 alarmCRT
92Channel 2 - Water 2-way valve: {{0}}Status Absolute differential pressure4 Bytes14.58 pressure (Pa)CRT
92Channel 2 - Room control unit: {{0}}Activate Boost mode1 Bit1.1 switchCT
93Channel 2 - Air VAV compact controller: {{0}}Addressing error1 Bit1.5 alarmCRT
93Channel 2 - Air rotary/damper actuator: {{0}}Addressing error1 Bit1.5 alarmCRT
93Channel 2 - Water rotary actuator: {{0}}Addressing error1 Bit1.5 alarmCRT
93Channel 2 - VAV universal controller: {{0}}MP-Bus address1 Byte5.10 counter pulses (0..255)CRT
93Channel 2 - Water 2-way valve: {{0}}Status Nominal differential pressure4 Bytes14.58 pressure (Pa)CRT
93Channel 2 - Room control unit: {{0}}Service information4 Bytes27.1 bit-combined info on/offCRT
94Channel 2 - Air VAV compact controller: {{0}}Configuration error1 Bit1.5 alarmCRT
94Channel 2 - Air rotary/damper actuator: {{0}}Configuration error1 Bit1.5 alarmCRT
94Channel 2 - Water rotary actuator: {{0}}Configuration error1 Bit1.5 alarmCRT
94Channel 2 - Water 2-way valve: {{0}}Status Glycol concentration2 Bytes8.10 percentage difference (%)CRT
94Channel 2 - Thermal energy meter: {{0}}Status Glycol concentration2 Bytes8.10 percentage difference (%)CRT
94Channel 2 - Room control unit: {{0}}Communication error1 Bit1.5 alarmCRT
95Channel 2 - Air VAV compact controller: {{0}}MP-Bus address1 Byte5.10 counter pulses (0..255)CRT
95Channel 2 - Air rotary/damper actuator: {{0}}MP-Bus address1 Byte5.10 counter pulses (0..255)CRT
95Channel 2 - Water rotary actuator: {{0}}MP-Bus address1 Byte5.10 counter pulses (0..255)CRT
95Channel 2 - Water 2-way valve: {{0}}Certified meter1 Bit1.2 booleanCRT
95Channel 2 - Thermal energy meter: {{0}}Certified meter1 Bit1.2 booleanCRT
95Channel 2 - Room control unit: {{0}}Addressing error1 Bit1.5 alarmCRT
96Channel 2 - Water 2-way valve: {{0}}Status Accumulated volume4 Bytes14.76 volume (m³)CRT
96Channel 2 - Thermal energy meter: {{0}}Status Accumulated volume4 Bytes14.76 volume (m³)CRT
96Channel 2 - Room control unit: {{0}}Configuration error1 Bit1.5 alarmCRT
97Channel 2 - Water 2-way valve: {{0}}Status Total energy cooling4 Bytes13.13 active energy (kWh)CRT
97Channel 2 - Thermal energy meter: {{0}}Status Total energy cooling4 Bytes13.13 active energy (kWh)CRT
97Channel 2 - Room control unit: {{0}}MP-Bus address1 Byte5.10 counter pulses (0..255)CRT
98Channel 2 - Water 2-way valve: {{0}}Status Total energy heating4 Bytes13.13 active energy (kWh)CRT
98Channel 2 - Thermal energy meter: {{0}}Status Total energy heating4 Bytes13.13 active energy (kWh)CRT
99Channel 2 - Water 2-way valve: {{0}}Energy meter serial number (upper digits)4 BytesCRT
99Channel 2 - Thermal energy meter: {{0}}Energy meter serial number (upper digits)4 BytesCRT
100Channel 2 - Water 2-way valve: {{0}}Energy meter serial number (lower digits)4 BytesCRT
100Channel 2 - Thermal energy meter: {{0}}Energy meter serial number (lower digits)4 BytesCRT
101Channel 2 - Water 2-way valve: {{0}}Status Delta temperature2 Bytes9.2 temperature difference (K)CRT
101Channel 2 - Thermal energy meter: {{0}}Status Delta temperature2 Bytes9.2 temperature difference (K)CRT
102Channel 2 - Water 2-way valve: {{0}}Status Delta-T Manager1 Bit1.2 booleanCRT
102Channel 2 - Thermal energy meter: {{0}}Status Delta-T Manager1 Bit1.2 booleanCRT
103Channel 2 - Water 2-way valve: {{0}}Status Delta-T Manager flow-dependent adjustment (scaling)1 Bit1.2 booleanCRT
103Channel 2 - Thermal energy meter: {{0}}Status Delta-T Manager flow-dependent adjustment (scaling)1 Bit1.2 booleanCRT
104Channel 2 - Water 2-way valve: {{0}}Temperature internal sensor2 Bytes9.1 temperature (°C)CRT
104Channel 2 - Thermal energy meter: {{0}}Temperature internal sensor2 Bytes9.1 temperature (°C)CRT
105Channel 2 - Water 2-way valve: {{0}}Temperature external sensor2 Bytes9.1 temperature (°C)CRT
105Channel 2 - Thermal energy meter: {{0}}Temperature external sensor2 Bytes9.1 temperature (°C)CRT
106Channel 2 - Water 2-way valve: {{0}}Sensor value (voltage)2 Bytes9.20 voltage (mV)CRT
106Channel 2 - Water 2-way valve: {{0}}Sensor value (percent)1 Byte5.1 percentage (0..100%)CRT
106Channel 2 - Water 2-way valve: {{0}}Sensor value (resistance)4 Bytes14.60 resistance (Ω)CRT
106Channel 2 - Water 2-way valve: {{0}}Sensor value (temperature)2 Bytes9.1 temperature (°C)CRT
106Channel 2 - Water 2-way valve: {{0}}Sensor value (switch)1 Bit1.1 switchCRT
106Channel 2 - Water 2-way valve: {{0}}Sensor value (air quality)2 Bytes9.8 parts/million (ppm)CRT
106Channel 2 - Water 2-way valve: {{0}}Sensor value (dew point alarm)1 Bit1.5 alarmCRT
106Channel 2 - Water 2-way valve: {{0}}Sensor value (humidity)2 Bytes9.7 humidity (%)CRT
106Channel 2 - Water 2-way valve: {{0}}Sensor value (humidity)1 Byte5.1 percentage (0..100%)CRT
106Channel 2 - Thermal energy meter: {{0}}Sensor value (voltage)2 Bytes9.20 voltage (mV)CRT
106Channel 2 - Thermal energy meter: {{0}}Sensor value (percent)1 Byte5.1 percentage (0..100%)CRT
106Channel 2 - Thermal energy meter: {{0}}Sensor value (resistance)4 Bytes14.60 resistance (Ω)CRT
106Channel 2 - Thermal energy meter: {{0}}Sensor value (temperature)2 Bytes9.1 temperature (°C)CRT
106Channel 2 - Thermal energy meter: {{0}}Sensor value (switch)1 Bit1.1 switchCRT
106Channel 2 - Thermal energy meter: {{0}}Sensor value (air quality)2 Bytes9.8 parts/million (ppm)CRT
106Channel 2 - Thermal energy meter: {{0}}Sensor value (dew point alarm)1 Bit1.5 alarmCRT
106Channel 2 - Thermal energy meter: {{0}}Sensor value (humidity)2 Bytes9.7 humidity (%)CRT
106Channel 2 - Thermal energy meter: {{0}}Sensor value (humidity)1 Byte5.1 percentage (0..100%)CRT
107Channel 2 - Water 2-way valve: {{0}}Error cyclical monitoring1 Bit1.5 alarmCRT
107Channel 2 - Thermal energy meter: {{0}}Error cyclical monitoring1 Bit1.5 alarmCRT
108Channel 2 - Water 2-way valve: {{0}}Override control active1 Bit1.11 stateCRT
108Channel 2 - Thermal energy meter: {{0}}Override control active1 Bit1.11 stateCRT
109Channel 2 - Water 2-way valve: {{0}}Gear disengagement active1 Bit1.11 stateCRT
109Channel 2 - Thermal energy meter: {{0}}Gear disengagement active1 Bit1.11 stateCRT
110Channel 2 - Water 2-way valve: {{0}}Error1 Bit1.5 alarmCRT
110Channel 2 - Thermal energy meter: {{0}}Error1 Bit1.5 alarmCRT
111Channel 2 - Water 2-way valve: {{0}}Sensor module must be replaced1 Bit1.5 alarmCRT
111Channel 2 - Thermal energy meter: {{0}}Sensor module must be replaced1 Bit1.5 alarmCRT
112Channel 2 - Water 2-way valve: {{0}}MP-Bus monitoring timed out1 Bit1.5 alarmCRT
112Channel 2 - Thermal energy meter: {{0}}MP-Bus monitoring timed out1 Bit1.5 alarmCRT
113Channel 2 - Water 2-way valve: {{0}}Service information4 Bytes27.1 bit-combined info on/offCRT
113Channel 2 - Thermal energy meter: {{0}}Service information4 Bytes27.1 bit-combined info on/offCRT
114Channel 2 - Water 2-way valve: {{0}}Communication error1 Bit1.5 alarmCRT
114Channel 2 - Thermal energy meter: {{0}}Communication error1 Bit1.5 alarmCRT
115Channel 2 - Water 2-way valve: {{0}}Addressing error1 Bit1.5 alarmCRT
115Channel 2 - Thermal energy meter: {{0}}Addressing error1 Bit1.5 alarmCRT
116Channel 2 - Water 2-way valve: {{0}}Configuration error1 Bit1.5 alarmCRT
116Channel 2 - Thermal energy meter: {{0}}Configuration error1 Bit1.5 alarmCRT
117Channel 2 - Water 2-way valve: {{0}}MP-Bus address1 Byte5.10 counter pulses (0..255)CRT
117Channel 2 - Thermal energy meter: {{0}}MP-Bus address1 Byte5.10 counter pulses (0..255)CRT
118Channel 3 - Air VAV compact controller: {{0}}Setpoint1 Byte5.1 percentage (0..100%)CWTUI
118Channel 3 - Air VAV compact controller: {{0}}Control value1 Byte5.1 percentage (0..100%)CWTUI
118Channel 3 - Air VAV compact controller: {{0}}Heating control value1 Byte5.1 percentage (0..100%)CWTUI
118Channel 3 - Air rotary/damper actuator: {{0}}Setpoint1 Byte5.1 percentage (0..100%)CWTUI
118Channel 3 - Air rotary/damper actuator: {{0}}Control value1 Byte5.1 percentage (0..100%)CWTUI
118Channel 3 - Air rotary/damper actuator: {{0}}Heating control value1 Byte5.1 percentage (0..100%)CWTUI
118Channel 3 - Water rotary actuator: {{0}}Setpoint1 Byte5.1 percentage (0..100%)CWTUI
118Channel 3 - Water rotary actuator: {{0}}Control value1 Byte5.1 percentage (0..100%)CWTUI
118Channel 3 - Water rotary actuator: {{0}}Heating control value1 Byte5.1 percentage (0..100%)CWTUI
118Channel 3 - VAV universal controller: {{0}}Setpoint1 Byte5.1 percentage (0..100%)CWTUI
118Channel 3 - Water 2-way valve: {{0}}Setpoint1 Byte5.1 percentage (0..100%)CWTUI
118Channel 3 - Thermal energy meter: {{0}}Setpoint1 Byte5.1 percentage (0..100%)CWTUI
118Channel 3 - Room control unit: {{0}}Confirm room temperature setpoint (absolute)2 Bytes9.1 temperature (°C)CWTUI
118Channel 3 - Room control unit: {{0}}Confirm room temperature setpoint (relative)2 Bytes9.2 temperature difference (K)CWTUI
119Channel 3 - Air VAV compact controller: {{0}}Cooling control value1 Byte5.1 percentage (0..100%)CWTUI
119Channel 3 - Air rotary/damper actuator: {{0}}Cooling control value1 Byte5.1 percentage (0..100%)CWTUI
119Channel 3 - Water rotary actuator: {{0}}Cooling control value1 Byte5.1 percentage (0..100%)CWTUI
119Channel 3 - VAV universal controller: {{0}}Override control1 ByteCWTUI
119Channel 3 - Water 2-way valve: {{0}}Setpoint absolute differential pressure4 Bytes14.58 pressure (Pa)CWTUI
119Channel 3 - Thermal energy meter: {{0}}Setpoint absolute differential pressure4 Bytes14.58 pressure (Pa)CWTUI
119Channel 3 - Room control unit: {{0}}Basic setpoint2 Bytes9.1 temperature (°C)CWTUI
120Channel 3 - Air VAV compact controller: {{0}}Heating/cooling changeover1 Bit1.100 cooling/heatingCWTUI
120Channel 3 - Air rotary/damper actuator: {{0}}Heating/cooling changeover1 Bit1.100 cooling/heatingCWTUI
120Channel 3 - Water rotary actuator: {{0}}Heating/cooling changeover1 Bit1.100 cooling/heatingCWTUI
120Channel 3 - VAV universal controller: {{0}}Start adjustment1 Bit1.17 triggerCW
120Channel 3 - Water 2-way valve: {{0}}Minimum flow rate1 Byte5.1 percentage (0..100%)CWTUI
120Channel 3 - Thermal energy meter: {{0}}Minimum flow rate1 Byte5.1 percentage (0..100%)CWTUI
120Channel 3 - Room control unit: {{0}}Confirm fan speed1 Byte5.1 percentage (0..100%)CWTUI
121Channel 3 - Air VAV compact controller: {{0}}Activate heating1 Bit1.3 enableCWTUI
121Channel 3 - Air rotary/damper actuator: {{0}}Activate heating1 Bit1.3 enableCWTUI
121Channel 3 - Water rotary actuator: {{0}}Activate heating1 Bit1.3 enableCWTUI
121Channel 3 - VAV universal controller: {{0}}Start synchronization1 Bit1.17 triggerCW
121Channel 3 - Water 2-way valve: {{0}}Maximum flow rate1 Byte5.1 percentage (0..100%)CWTUI
121Channel 3 - Thermal energy meter: {{0}}Maximum flow rate1 Byte5.1 percentage (0..100%)CWTUI
121Channel 3 - Room control unit: {{0}}Request fan automatic mode1 Bit1.3 enableCWTUI
122Channel 3 - Air VAV compact controller: {{0}}Activate cooling1 Bit1.3 enableCWTUI
122Channel 3 - Air rotary/damper actuator: {{0}}Activate cooling1 Bit1.3 enableCWTUI
122Channel 3 - Water rotary actuator: {{0}}Activate cooling1 Bit1.3 enableCWTUI
122Channel 3 - VAV universal controller: {{0}}Minimum flow rate1 Byte5.1 percentage (0..100%)CWTUI
122Channel 3 - VAV universal controller: {{0}}Minimum differential pressure1 Byte5.1 percentage (0..100%)CWTUI
122Channel 3 - Water 2-way valve: {{0}}Maximum power limit1 Byte5.1 percentage (0..100%)CWTUI
122Channel 3 - Thermal energy meter: {{0}}Maximum power limit1 Byte5.1 percentage (0..100%)CWTUI
122Channel 3 - Room control unit: {{0}}Display warning icon1 Bit1.3 enableCWTUI
123Channel 3 - Air VAV compact controller: {{0}}Override control1 ByteCWTUI
123Channel 3 - Air rotary/damper actuator: {{0}}Override control1 ByteCWTUI
123Channel 3 - Water rotary actuator: {{0}}Override control1 ByteCWTUI
123Channel 3 - VAV universal controller: {{0}}Maximum flow rate1 Byte5.1 percentage (0..100%)CWTUI
123Channel 3 - VAV universal controller: {{0}}Maximum differential pressure1 Byte5.1 percentage (0..100%)CWTUI
123Channel 3 - Water 2-way valve: {{0}}Activate Delta-T Manager1 Bit1.3 enableCWTUI
123Channel 3 - Thermal energy meter: {{0}}Activate Delta-T Manager1 Bit1.3 enableCWTUI
123Channel 3 - Room control unit: {{0}}Display window icon1 Bit1.3 enableCWTUI
124Channel 3 - Air VAV compact controller: {{0}}Minimum position1 Byte5.1 percentage (0..100%)CWTUI
124Channel 3 - Air VAV compact controller: {{0}}Minimum flow rate1 Byte5.1 percentage (0..100%)CWTUI
124Channel 3 - Air rotary/damper actuator: {{0}}Minimum position1 Byte5.1 percentage (0..100%)CWTUI
124Channel 3 - Air rotary/damper actuator: {{0}}Minimum flow rate1 Byte5.1 percentage (0..100%)CWTUI
124Channel 3 - Water rotary actuator: {{0}}Minimum position1 Byte5.1 percentage (0..100%)CWTUI
124Channel 3 - Water rotary actuator: {{0}}Minimum flow rate1 Byte5.1 percentage (0..100%)CWTUI
124Channel 3 - VAV universal controller: {{0}}Status Analog input signal1 Byte5.1 percentage (0..100%)CRT
124Channel 3 - Water 2-way valve: {{0}}Activate Delta-T Manager flow-dependent adjustment (scaling)1 Bit1.3 enableCWTUI
124Channel 3 - Thermal energy meter: {{0}}Activate Delta-T Manager flow-dependent adjustment (scaling)1 Bit1.3 enableCWTUI
124Channel 3 - Room control unit: {{0}}Status RTC controller2 Bytes22.103 combined status RTCCWTUI
125Channel 3 - Air VAV compact controller: {{0}}Maximum position1 Byte5.1 percentage (0..100%)CWTUI
125Channel 3 - Air VAV compact controller: {{0}}Maximum flow rate1 Byte5.1 percentage (0..100%)CWTUI
125Channel 3 - Air rotary/damper actuator: {{0}}Maximum position1 Byte5.1 percentage (0..100%)CWTUI
125Channel 3 - Air rotary/damper actuator: {{0}}Maximum flow rate1 Byte5.1 percentage (0..100%)CWTUI
125Channel 3 - Water rotary actuator: {{0}}Maximum position1 Byte5.1 percentage (0..100%)CWTUI
125Channel 3 - Water rotary actuator: {{0}}Maximum flow rate1 Byte5.1 percentage (0..100%)CWTUI
125Channel 3 - VAV universal controller: {{0}}Status Relative position1 Byte5.1 percentage (0..100%)CRT
125Channel 3 - Water 2-way valve: {{0}}Setpoint Delta-T limitation2 Bytes9.2 temperature difference (K)CWTUI
125Channel 3 - Thermal energy meter: {{0}}Setpoint Delta-T limitation2 Bytes9.2 temperature difference (K)CWTUI
125Channel 3 - Room control unit: {{0}}Receive status Heating1 Bit1.3 enableCWTUI
126Channel 3 - Air VAV compact controller: {{0}}Start test run1 Bit1.17 triggerCW
126Channel 3 - Air rotary/damper actuator: {{0}}Start test run1 Bit1.17 triggerCW
126Channel 3 - Water rotary actuator: {{0}}Start test run1 Bit1.17 triggerCW
126Channel 3 - VAV universal controller: {{0}}Status Absolute position2 Bytes8.11 rotation angle (°)CRT
126Channel 3 - Water 2-way valve: {{0}}Setpoint absolute flow at Delta-T4 Bytes14.1201 volume flux for meters (1/ls)CWTUI
126Channel 3 - Thermal energy meter: {{0}}Setpoint absolute flow at Delta-T4 Bytes14.1201 volume flux for meters (1/ls)CWTUI
126Channel 3 - Room control unit: {{0}}Receive status Cooling1 Bit1.3 enableCWTUI
127Channel 3 - Air VAV compact controller: {{0}}Start adjustment1 Bit1.17 triggerCW
127Channel 3 - Air rotary/damper actuator: {{0}}Start adjustment1 Bit1.17 triggerCW
127Channel 3 - Water rotary actuator: {{0}}Start adjustment1 Bit1.17 triggerCW
127Channel 3 - VAV universal controller: {{0}}Status Minimum flow rate1 Byte5.1 percentage (0..100%)CRT
127Channel 3 - VAV universal controller: {{0}}Status Minimum differential pressure1 Byte5.1 percentage (0..100%)CRT
127Channel 3 - Water 2-way valve: {{0}}Start synchronization1 Bit1.17 triggerCW
127Channel 3 - Thermal energy meter: {{0}}Start synchronization1 Bit1.17 triggerCW
127Channel 3 - Room control unit: {{0}}Confirm RTR operating mode1 Byte20.102 HVAC modeCWTUI
128Channel 3 - Air VAV compact controller: {{0}}Status Relative position1 Byte5.1 percentage (0..100%)CRT
128Channel 3 - Air rotary/damper actuator: {{0}}Status Relative position1 Byte5.1 percentage (0..100%)CRT
128Channel 3 - Water rotary actuator: {{0}}Status Relative position1 Byte5.1 percentage (0..100%)CRT
128Channel 3 - VAV universal controller: {{0}}Status Maximum flow rate1 Byte5.1 percentage (0..100%)CRT
128Channel 3 - VAV universal controller: {{0}}Status Maximum differential pressure1 Byte5.1 percentage (0..100%)CRT
128Channel 3 - Water 2-way valve: {{0}}Override control1 ByteCWTUI
128Channel 3 - Thermal energy meter: {{0}}Override control1 ByteCWTUI
128Channel 3 - Room control unit: {{0}}Block local operation1 Bit1.3 enableCWTUI
129Channel 3 - Air VAV compact controller: {{0}}Status Absolute position (rotation angle)2 Bytes8.11 rotation angle (°)CRT
129Channel 3 - Air VAV compact controller: {{0}}Status Absolute position (millimeters)2 Bytes7.11 length (mm)CRT
129Channel 3 - Air rotary/damper actuator: {{0}}Status Absolute position (rotation angle)2 Bytes8.11 rotation angle (°)CRT
129Channel 3 - Air rotary/damper actuator: {{0}}Status Absolute position (millimeters)2 Bytes7.11 length (mm)CRT
129Channel 3 - Water rotary actuator: {{0}}Status Absolute position (rotation angle)2 Bytes8.11 rotation angle (°)CRT
129Channel 3 - Water rotary actuator: {{0}}Status Absolute position (millimeters)2 Bytes7.11 length (mm)CRT
129Channel 3 - VAV universal controller: {{0}}Status Relative flow rate1 Byte5.1 percentage (0..100%)CRT
129Channel 3 - Water 2-way valve: {{0}}Status Analog input signal1 Byte5.1 percentage (0..100%)CRT
129Channel 3 - Thermal energy meter: {{0}}Status Analog input signal1 Byte5.1 percentage (0..100%)CRT
129Channel 3 - Room control unit: {{0}}Display Boost mode1 Bit1.1 switchCWTUI
130Channel 3 - Air VAV compact controller: {{0}}Status Nominal range (rotation angle)2 Bytes8.11 rotation angle (°)CRT
130Channel 3 - Air VAV compact controller: {{0}}Status Nominal range (millimeters)2 Bytes7.11 length (mm)CRT
130Channel 3 - Air rotary/damper actuator: {{0}}Status Nominal range (rotation angle)2 Bytes8.11 rotation angle (°)CRT
130Channel 3 - Air rotary/damper actuator: {{0}}Status Nominal range (millimeters)2 Bytes7.11 length (mm)CRT
130Channel 3 - Water rotary actuator: {{0}}Status Nominal range (rotation angle)2 Bytes8.11 rotation angle (°)CRT
130Channel 3 - Water rotary actuator: {{0}}Status Nominal range (millimeters)2 Bytes7.11 length (mm)CRT
130Channel 3 - VAV universal controller: {{0}}Status Absolute flow rate4 Bytes14.77 volume flux (m³/s)CRT
130Channel 3 - VAV universal controller: {{0}}Status Absolute flow rate2 Bytes9.9 air flow (m³/h)CRT
130Channel 3 - Water 2-way valve: {{0}}Status Relative position1 Byte5.1 percentage (0..100%)CRT
130Channel 3 - Thermal energy meter: {{0}}Status Relative position1 Byte5.1 percentage (0..100%)CRT
130Channel 3 - Room control unit: {{0}}Status Room temperature2 Bytes9.1 temperature (°C)CRT
131Channel 3 - Air VAV compact controller: {{0}}Status Relative flow rate1 Byte5.1 percentage (0..100%)CRT
131Channel 3 - Air rotary/damper actuator: {{0}}Status Relative flow rate1 Byte5.1 percentage (0..100%)CRT
131Channel 3 - Water rotary actuator: {{0}}Status Relative flow rate1 Byte5.1 percentage (0..100%)CRT
131Channel 3 - VAV universal controller: {{0}}Status Nominal flow rate4 Bytes14.77 volume flux (m³/s)CRT
131Channel 3 - VAV universal controller: {{0}}Status Nominal flow rate2 Bytes9.9 air flow (m³/h)CRT
131Channel 3 - Water 2-way valve: {{0}}Status Absolute position2 Bytes8.11 rotation angle (°)CRT
131Channel 3 - Thermal energy meter: {{0}}Status Absolute position2 Bytes8.11 rotation angle (°)CRT
131Channel 3 - Room control unit: {{0}}Status Relative humidity1 Byte5.1 percentage (0..100%)CRT
132Channel 3 - Air VAV compact controller: {{0}}Status Absolute flow rate4 Bytes14.77 volume flux (m³/s)CRT
132Channel 3 - Air VAV compact controller: {{0}}Status Absolute flow rate2 Bytes9.9 air flow (m³/h)CRT
132Channel 3 - Air rotary/damper actuator: {{0}}Status Absolute flow rate4 Bytes14.77 volume flux (m³/s)CRT
132Channel 3 - Air rotary/damper actuator: {{0}}Status Absolute flow rate2 Bytes9.9 air flow (m³/h)CRT
132Channel 3 - Water rotary actuator: {{0}}Status Absolute flow rate4 Bytes14.77 volume flux (m³/s)CRT
132Channel 3 - Water rotary actuator: {{0}}Status Absolute flow rate2 Bytes9.9 air flow (m³/h)CRT
132Channel 3 - VAV universal controller: {{0}}Status Relative differential pressure2 Bytes8.10 percentage difference (%)CRT
132Channel 3 - Water 2-way valve: {{0}}Status Relative flow rate1 Byte5.1 percentage (0..100%)CRT
132Channel 3 - Water 2-way valve: {{0}}Status Relative flow rate2 Bytes8.10 percentage difference (%)CRT
132Channel 3 - Thermal energy meter: {{0}}Status Relative flow rate1 Byte5.1 percentage (0..100%)CRT
132Channel 3 - Thermal energy meter: {{0}}Status Relative flow rate2 Bytes8.10 percentage difference (%)CRT
132Channel 3 - Room control unit: {{0}}CO2 value2 Bytes9.8 parts/million (ppm)CRT
133Channel 3 - Air VAV compact controller: {{0}}Status Nominal flow rate4 Bytes14.77 volume flux (m³/s)CRT
133Channel 3 - Air VAV compact controller: {{0}}Status Nominal flow rate2 Bytes9.9 air flow (m³/h)CRT
133Channel 3 - Air rotary/damper actuator: {{0}}Status Nominal flow rate4 Bytes14.77 volume flux (m³/s)CRT
133Channel 3 - Air rotary/damper actuator: {{0}}Status Nominal flow rate2 Bytes9.9 air flow (m³/h)CRT
133Channel 3 - Water rotary actuator: {{0}}Status Nominal flow rate4 Bytes14.77 volume flux (m³/s)CRT
133Channel 3 - Water rotary actuator: {{0}}Status Nominal flow rate2 Bytes9.9 air flow (m³/h)CRT
133Channel 3 - VAV universal controller: {{0}}Status Absolute differential pressure4 Bytes14.58 pressure (Pa)CRT
133Channel 3 - Water 2-way valve: {{0}}Status Absolute flow rate4 Bytes14.1201 volume flux for meters (1/ls)CRT
133Channel 3 - Thermal energy meter: {{0}}Status Absolute flow rate4 Bytes14.1201 volume flux for meters (1/ls)CRT
133Channel 3 - Room control unit: {{0}}Air quality OK1 Bit1.2 booleanCRT
134Channel 3 - Air VAV compact controller: {{0}}Status Minimum position1 Byte5.1 percentage (0..100%)CRT
134Channel 3 - Air VAV compact controller: {{0}}Status Minimum flow rate1 Byte5.1 percentage (0..100%)CRT
134Channel 3 - Air rotary/damper actuator: {{0}}Status Minimum position1 Byte5.1 percentage (0..100%)CRT
134Channel 3 - Air rotary/damper actuator: {{0}}Status Minimum flow rate1 Byte5.1 percentage (0..100%)CRT
134Channel 3 - Water rotary actuator: {{0}}Status Minimum position1 Byte5.1 percentage (0..100%)CRT
134Channel 3 - Water rotary actuator: {{0}}Status Minimum flow rate1 Byte5.1 percentage (0..100%)CRT
134Channel 3 - VAV universal controller: {{0}}Status Nominal differential pressure4 Bytes14.58 pressure (Pa)CRT
134Channel 3 - Water 2-way valve: {{0}}Status Minimum flow rate1 Byte5.1 percentage (0..100%)CRT
134Channel 3 - Thermal energy meter: {{0}}Status Minimum flow rate1 Byte5.1 percentage (0..100%)CRT
134Channel 3 - Room control unit: {{0}}Air quality warning1 Bit1.2 booleanCRT
135Channel 3 - Air VAV compact controller: {{0}}Status Maximum position1 Byte5.1 percentage (0..100%)CRT
135Channel 3 - Air VAV compact controller: {{0}}Status Maximum flow rate1 Byte5.1 percentage (0..100%)CRT
135Channel 3 - Air rotary/damper actuator: {{0}}Status Maximum position1 Byte5.1 percentage (0..100%)CRT
135Channel 3 - Air rotary/damper actuator: {{0}}Status Maximum flow rate1 Byte5.1 percentage (0..100%)CRT
135Channel 3 - Water rotary actuator: {{0}}Status Maximum position1 Byte5.1 percentage (0..100%)CRT
135Channel 3 - Water rotary actuator: {{0}}Status Maximum flow rate1 Byte5.1 percentage (0..100%)CRT
135Channel 3 - VAV universal controller: {{0}}Sensor value (voltage)2 Bytes9.20 voltage (mV)CRT
135Channel 3 - VAV universal controller: {{0}}Sensor value (percent)1 Byte5.1 percentage (0..100%)CRT
135Channel 3 - VAV universal controller: {{0}}Sensor value (resistance)4 Bytes14.60 resistance (Ω)CRT
135Channel 3 - VAV universal controller: {{0}}Sensor value (switch)1 Bit1.1 switchCRT
135Channel 3 - VAV universal controller: {{0}}Sensor value (temperature)2 Bytes9.1 temperature (°C)CRT
135Channel 3 - VAV universal controller: {{0}}Sensor value (humidity)2 Bytes9.7 humidity (%)CRT
135Channel 3 - VAV universal controller: {{0}}Sensor value (humidity)1 Byte5.1 percentage (0..100%)CRT
135Channel 3 - VAV universal controller: {{0}}Sensor value (air quality)2 Bytes9.8 parts/million (ppm)CRT
135Channel 3 - VAV universal controller: {{0}}Sensor value (dew point alarm)1 Bit1.5 alarmCRT
135Channel 3 - Water 2-way valve: {{0}}Status Maximum flow rate1 Byte5.1 percentage (0..100%)CRT
135Channel 3 - Thermal energy meter: {{0}}Status Maximum flow rate1 Byte5.1 percentage (0..100%)CRT
135Channel 3 - Room control unit: {{0}}Air quality alarm1 Bit1.2 booleanCRT
136Channel 3 - Air VAV compact controller: {{0}}Sensor value (voltage)2 Bytes9.20 voltage (mV)CRT
136Channel 3 - Air VAV compact controller: {{0}}Sensor value (percent)1 Byte5.1 percentage (0..100%)CRT
136Channel 3 - Air VAV compact controller: {{0}}Sensor value (resistance)4 Bytes14.60 resistance (Ω)CRT
136Channel 3 - Air VAV compact controller: {{0}}Sensor value (switch)1 Bit1.1 switchCRT
136Channel 3 - Air VAV compact controller: {{0}}Sensor value (temperature)2 Bytes9.1 temperature (°C)CRT
136Channel 3 - Air VAV compact controller: {{0}}Sensor value (humidity)2 Bytes9.7 humidity (%)CRT
136Channel 3 - Air VAV compact controller: {{0}}Sensor value (humidity)1 Byte5.1 percentage (0..100%)CRT
136Channel 3 - Air VAV compact controller: {{0}}Sensor value (air quality)2 Bytes9.8 parts/million (ppm)CRT
136Channel 3 - Air VAV compact controller: {{0}}Sensor value (dew point alarm)1 Bit1.5 alarmCRT
136Channel 3 - Air rotary/damper actuator: {{0}}Sensor value (voltage)2 Bytes9.20 voltage (mV)CRT
136Channel 3 - Air rotary/damper actuator: {{0}}Sensor value (percent)1 Byte5.1 percentage (0..100%)CRT
136Channel 3 - Air rotary/damper actuator: {{0}}Sensor value (resistance)4 Bytes14.60 resistance (Ω)CRT
136Channel 3 - Air rotary/damper actuator: {{0}}Sensor value (switch)1 Bit1.1 switchCRT
136Channel 3 - Air rotary/damper actuator: {{0}}Sensor value (temperature)2 Bytes9.1 temperature (°C)CRT
136Channel 3 - Air rotary/damper actuator: {{0}}Sensor value (humidity)2 Bytes9.7 humidity (%)CRT
136Channel 3 - Air rotary/damper actuator: {{0}}Sensor value (humidity)1 Byte5.1 percentage (0..100%)CRT
136Channel 3 - Air rotary/damper actuator: {{0}}Sensor value (air quality)2 Bytes9.8 parts/million (ppm)CRT
136Channel 3 - Air rotary/damper actuator: {{0}}Sensor value (dew point alarm)1 Bit1.5 alarmCRT
136Channel 3 - Water rotary actuator: {{0}}Sensor value (voltage)2 Bytes9.20 voltage (mV)CRT
136Channel 3 - Water rotary actuator: {{0}}Sensor value (percent)1 Byte5.1 percentage (0..100%)CRT
136Channel 3 - Water rotary actuator: {{0}}Sensor value (resistance)4 Bytes14.60 resistance (Ω)CRT
136Channel 3 - Water rotary actuator: {{0}}Sensor value (switch)1 Bit1.1 switchCRT
136Channel 3 - Water rotary actuator: {{0}}Sensor value (temperature)2 Bytes9.1 temperature (°C)CRT
136Channel 3 - Water rotary actuator: {{0}}Sensor value (humidity)2 Bytes9.7 humidity (%)CRT
136Channel 3 - Water rotary actuator: {{0}}Sensor value (humidity)1 Byte5.1 percentage (0..100%)CRT
136Channel 3 - Water rotary actuator: {{0}}Sensor value (air quality)2 Bytes9.8 parts/million (ppm)CRT
136Channel 3 - Water rotary actuator: {{0}}Sensor value (dew point alarm)1 Bit1.5 alarmCRT
136Channel 3 - VAV universal controller: {{0}}Gear disengagement active1 Bit1.11 stateCRT
136Channel 3 - Water 2-way valve: {{0}}Status Nominal flow rate4 Bytes14.1201 volume flux for meters (1/ls)CRT
136Channel 3 - Thermal energy meter: {{0}}Status Nominal flow rate4 Bytes14.1201 volume flux for meters (1/ls)CRT
136Channel 3 - Room control unit: {{0}}Binary input1 Bit1.1 switchCRT
137Channel 3 - Air VAV compact controller: {{0}}Error cyclical monitoring1 Bit1.5 alarmCRT
137Channel 3 - Air rotary/damper actuator: {{0}}Error cyclical monitoring1 Bit1.5 alarmCRT
137Channel 3 - Water rotary actuator: {{0}}Error cyclical monitoring1 Bit1.5 alarmCRT
137Channel 3 - VAV universal controller: {{0}}Error1 Bit1.5 alarmCRT
137Channel 3 - Water 2-way valve: {{0}}Status Relative power1 Byte5.1 percentage (0..100%)CRT
137Channel 3 - Water 2-way valve: {{0}}Status Relative power2 Bytes8.10 percentage difference (%)CRT
137Channel 3 - Thermal energy meter: {{0}}Status Relative power1 Byte5.1 percentage (0..100%)CRT
137Channel 3 - Thermal energy meter: {{0}}Status Relative power2 Bytes8.10 percentage difference (%)CRT
137Channel 3 - Room control unit: {{0}}Dew point temperature2 Bytes9.1 temperature (°C)CRT
138Channel 3 - Air VAV compact controller: {{0}}Override control active1 Bit1.11 stateCRT
138Channel 3 - Air rotary/damper actuator: {{0}}Override control active1 Bit1.11 stateCRT
138Channel 3 - Water rotary actuator: {{0}}Override control active1 Bit1.11 stateCRT
138Channel 3 - VAV universal controller: {{0}}Error cyclical monitoring1 Bit1.5 alarmCRT
138Channel 3 - Water 2-way valve: {{0}}Status Absolute cooling power4 Bytes14.56 power (W)CRT
138Channel 3 - Thermal energy meter: {{0}}Status Absolute cooling power4 Bytes14.56 power (W)CRT
138Channel 3 - Room control unit: {{0}}Request room temperature setpoint (absolute)2 Bytes9.1 temperature (°C)CT
139Channel 3 - Air VAV compact controller: {{0}}Gear disengagement active1 Bit1.11 stateCRT
139Channel 3 - Air rotary/damper actuator: {{0}}Gear disengagement active1 Bit1.11 stateCRT
139Channel 3 - Water rotary actuator: {{0}}Gear disengagement active1 Bit1.11 stateCRT
139Channel 3 - VAV universal controller: {{0}}Override control active1 Bit1.11 stateCRT
139Channel 3 - Water 2-way valve: {{0}}Status Absolute heating power4 Bytes14.56 power (W)CRT
139Channel 3 - Thermal energy meter: {{0}}Status Absolute heating power4 Bytes14.56 power (W)CRT
139Channel 3 - Room control unit: {{0}}Request room temperature setpoint (relative)2 Bytes9.2 temperature difference (K)CT
140Channel 3 - Air VAV compact controller: {{0}}Error1 Bit1.5 alarmCRT
140Channel 3 - Air rotary/damper actuator: {{0}}Error1 Bit1.5 alarmCRT
140Channel 3 - Water rotary actuator: {{0}}Error1 Bit1.5 alarmCRT
140Channel 3 - VAV universal controller: {{0}}Service information4 Bytes27.1 bit-combined info on/offCRT
140Channel 3 - Water 2-way valve: {{0}}Status Maximum power limit1 Byte5.1 percentage (0..100%)CRT
140Channel 3 - Thermal energy meter: {{0}}Status Maximum power limit1 Byte5.1 percentage (0..100%)CRT
140Channel 3 - Room control unit: {{0}}Request fan speed1 Byte5.1 percentage (0..100%)CT
141Channel 3 - Air VAV compact controller: {{0}}Service information4 Bytes27.1 bit-combined info on/offCRT
141Channel 3 - Air rotary/damper actuator: {{0}}Service information4 Bytes27.1 bit-combined info on/offCRT
141Channel 3 - Water rotary actuator: {{0}}Service information4 Bytes27.1 bit-combined info on/offCRT
141Channel 3 - VAV universal controller: {{0}}Communication error1 Bit1.5 alarmCRT
141Channel 3 - Water 2-way valve: {{0}}Status Nominal power4 Bytes14.56 power (W)CRT
141Channel 3 - Thermal energy meter: {{0}}Status Nominal power4 Bytes14.56 power (W)CRT
141Channel 3 - Room control unit: {{0}}Confirm fan automatic mode1 Bit1.3 enableCT
142Channel 3 - Air VAV compact controller: {{0}}Reset service information1 Bit1.10 start/stopCW
142Channel 3 - Air rotary/damper actuator: {{0}}Reset service information1 Bit1.10 start/stopCW
142Channel 3 - Water rotary actuator: {{0}}Reset service information1 Bit1.10 start/stopCW
142Channel 3 - VAV universal controller: {{0}}Addressing error1 Bit1.5 alarmCRT
142Channel 3 - Water 2-way valve: {{0}}Status Relative differential pressure1 Byte5.1 percentage (0..100%)CRT
142Channel 3 - Room control unit: {{0}}Request RTR operating mode1 Byte20.102 HVAC modeCT
143Channel 3 - Air VAV compact controller: {{0}}Communication error1 Bit1.5 alarmCRT
143Channel 3 - Air rotary/damper actuator: {{0}}Communication error1 Bit1.5 alarmCRT
143Channel 3 - Water rotary actuator: {{0}}Communication error1 Bit1.5 alarmCRT
143Channel 3 - VAV universal controller: {{0}}Configuration error1 Bit1.5 alarmCRT
143Channel 3 - Water 2-way valve: {{0}}Status Absolute differential pressure4 Bytes14.58 pressure (Pa)CRT
143Channel 3 - Room control unit: {{0}}Activate Boost mode1 Bit1.1 switchCT
144Channel 3 - Air VAV compact controller: {{0}}Addressing error1 Bit1.5 alarmCRT
144Channel 3 - Air rotary/damper actuator: {{0}}Addressing error1 Bit1.5 alarmCRT
144Channel 3 - Water rotary actuator: {{0}}Addressing error1 Bit1.5 alarmCRT
144Channel 3 - VAV universal controller: {{0}}MP-Bus address1 Byte5.10 counter pulses (0..255)CRT
144Channel 3 - Water 2-way valve: {{0}}Status Nominal differential pressure4 Bytes14.58 pressure (Pa)CRT
144Channel 3 - Room control unit: {{0}}Service information4 Bytes27.1 bit-combined info on/offCRT
145Channel 3 - Air VAV compact controller: {{0}}Configuration error1 Bit1.5 alarmCRT
145Channel 3 - Air rotary/damper actuator: {{0}}Configuration error1 Bit1.5 alarmCRT
145Channel 3 - Water rotary actuator: {{0}}Configuration error1 Bit1.5 alarmCRT
145Channel 3 - Water 2-way valve: {{0}}Status Glycol concentration2 Bytes8.10 percentage difference (%)CRT
145Channel 3 - Thermal energy meter: {{0}}Status Glycol concentration2 Bytes8.10 percentage difference (%)CRT
145Channel 3 - Room control unit: {{0}}Communication error1 Bit1.5 alarmCRT
146Channel 3 - Air VAV compact controller: {{0}}MP-Bus address1 Byte5.10 counter pulses (0..255)CRT
146Channel 3 - Air rotary/damper actuator: {{0}}MP-Bus address1 Byte5.10 counter pulses (0..255)CRT
146Channel 3 - Water rotary actuator: {{0}}MP-Bus address1 Byte5.10 counter pulses (0..255)CRT
146Channel 3 - Water 2-way valve: {{0}}Certified meter1 Bit1.2 booleanCRT
146Channel 3 - Thermal energy meter: {{0}}Certified meter1 Bit1.2 booleanCRT
146Channel 3 - Room control unit: {{0}}Addressing error1 Bit1.5 alarmCRT
147Channel 3 - Water 2-way valve: {{0}}Status Accumulated volume4 Bytes14.76 volume (m³)CRT
147Channel 3 - Thermal energy meter: {{0}}Status Accumulated volume4 Bytes14.76 volume (m³)CRT
147Channel 3 - Room control unit: {{0}}Configuration error1 Bit1.5 alarmCRT
148Channel 3 - Water 2-way valve: {{0}}Status Total energy cooling4 Bytes13.13 active energy (kWh)CRT
148Channel 3 - Thermal energy meter: {{0}}Status Total energy cooling4 Bytes13.13 active energy (kWh)CRT
148Channel 3 - Room control unit: {{0}}MP-Bus address1 Byte5.10 counter pulses (0..255)CRT
149Channel 3 - Water 2-way valve: {{0}}Status Total energy heating4 Bytes13.13 active energy (kWh)CRT
149Channel 3 - Thermal energy meter: {{0}}Status Total energy heating4 Bytes13.13 active energy (kWh)CRT
150Channel 3 - Water 2-way valve: {{0}}Energy meter serial number (upper digits)4 BytesCRT
150Channel 3 - Thermal energy meter: {{0}}Energy meter serial number (upper digits)4 BytesCRT
151Channel 3 - Water 2-way valve: {{0}}Energy meter serial number (lower digits)4 BytesCRT
151Channel 3 - Thermal energy meter: {{0}}Energy meter serial number (lower digits)4 BytesCRT
152Channel 3 - Water 2-way valve: {{0}}Status Delta temperature2 Bytes9.2 temperature difference (K)CRT
152Channel 3 - Thermal energy meter: {{0}}Status Delta temperature2 Bytes9.2 temperature difference (K)CRT
153Channel 3 - Water 2-way valve: {{0}}Status Delta-T Manager1 Bit1.2 booleanCRT
153Channel 3 - Thermal energy meter: {{0}}Status Delta-T Manager1 Bit1.2 booleanCRT
154Channel 3 - Water 2-way valve: {{0}}Status Delta-T Manager flow-dependent adjustment (scaling)1 Bit1.2 booleanCRT
154Channel 3 - Thermal energy meter: {{0}}Status Delta-T Manager flow-dependent adjustment (scaling)1 Bit1.2 booleanCRT
155Channel 3 - Water 2-way valve: {{0}}Temperature internal sensor2 Bytes9.1 temperature (°C)CRT
155Channel 3 - Thermal energy meter: {{0}}Temperature internal sensor2 Bytes9.1 temperature (°C)CRT
156Channel 3 - Water 2-way valve: {{0}}Temperature external sensor2 Bytes9.1 temperature (°C)CRT
156Channel 3 - Thermal energy meter: {{0}}Temperature external sensor2 Bytes9.1 temperature (°C)CRT
157Channel 3 - Water 2-way valve: {{0}}Sensor value (voltage)2 Bytes9.20 voltage (mV)CRT
157Channel 3 - Water 2-way valve: {{0}}Sensor value (percent)1 Byte5.1 percentage (0..100%)CRT
157Channel 3 - Water 2-way valve: {{0}}Sensor value (resistance)4 Bytes14.60 resistance (Ω)CRT
157Channel 3 - Water 2-way valve: {{0}}Sensor value (temperature)2 Bytes9.1 temperature (°C)CRT
157Channel 3 - Water 2-way valve: {{0}}Sensor value (switch)1 Bit1.1 switchCRT
157Channel 3 - Water 2-way valve: {{0}}Sensor value (air quality)2 Bytes9.8 parts/million (ppm)CRT
157Channel 3 - Water 2-way valve: {{0}}Sensor value (dew point alarm)1 Bit1.5 alarmCRT
157Channel 3 - Water 2-way valve: {{0}}Sensor value (humidity)2 Bytes9.7 humidity (%)CRT
157Channel 3 - Water 2-way valve: {{0}}Sensor value (humidity)1 Byte5.1 percentage (0..100%)CRT
157Channel 3 - Thermal energy meter: {{0}}Sensor value (voltage)2 Bytes9.20 voltage (mV)CRT
157Channel 3 - Thermal energy meter: {{0}}Sensor value (percent)1 Byte5.1 percentage (0..100%)CRT
157Channel 3 - Thermal energy meter: {{0}}Sensor value (resistance)4 Bytes14.60 resistance (Ω)CRT
157Channel 3 - Thermal energy meter: {{0}}Sensor value (temperature)2 Bytes9.1 temperature (°C)CRT
157Channel 3 - Thermal energy meter: {{0}}Sensor value (switch)1 Bit1.1 switchCRT
157Channel 3 - Thermal energy meter: {{0}}Sensor value (air quality)2 Bytes9.8 parts/million (ppm)CRT
157Channel 3 - Thermal energy meter: {{0}}Sensor value (dew point alarm)1 Bit1.5 alarmCRT
157Channel 3 - Thermal energy meter: {{0}}Sensor value (humidity)2 Bytes9.7 humidity (%)CRT
157Channel 3 - Thermal energy meter: {{0}}Sensor value (humidity)1 Byte5.1 percentage (0..100%)CRT
158Channel 3 - Water 2-way valve: {{0}}Error cyclical monitoring1 Bit1.5 alarmCRT
158Channel 3 - Thermal energy meter: {{0}}Error cyclical monitoring1 Bit1.5 alarmCRT
159Channel 3 - Water 2-way valve: {{0}}Override control active1 Bit1.11 stateCRT
159Channel 3 - Thermal energy meter: {{0}}Override control active1 Bit1.11 stateCRT
160Channel 3 - Water 2-way valve: {{0}}Gear disengagement active1 Bit1.11 stateCRT
160Channel 3 - Thermal energy meter: {{0}}Gear disengagement active1 Bit1.11 stateCRT
161Channel 3 - Water 2-way valve: {{0}}Error1 Bit1.5 alarmCRT
161Channel 3 - Thermal energy meter: {{0}}Error1 Bit1.5 alarmCRT
162Channel 3 - Water 2-way valve: {{0}}Sensor module must be replaced1 Bit1.5 alarmCRT
162Channel 3 - Thermal energy meter: {{0}}Sensor module must be replaced1 Bit1.5 alarmCRT
163Channel 3 - Water 2-way valve: {{0}}MP-Bus monitoring timed out1 Bit1.5 alarmCRT

First 1000 of 5340 group objects shown. Download the .knxprod for the full list.

Parameters (148)
ParameterTypeDefault
MP serial numbertext00000-00000-000-000
1#Device Settings$CentralunsignedInt 0…2550
2#Channel 1$Channel 1unsignedInt 0…2550
3#Channel 2$Channel 2unsignedInt 0…2550
4#Channel 3$Channel 3unsignedInt 0…2550
5#Channel 4$Channel 4unsignedInt 0…2550
6#Channel 5$Channel 5unsignedInt 0…2550
7#Channel 6$Channel 6unsignedInt 0…2550
8#Channel 7$Channel 7unsignedInt 0…2550
9#Channel 8$Channel 8unsignedInt 0…2550
10#Channel 9$Channel 9unsignedInt 0…2550
11#Channel 10$Channel 10unsignedInt 0…2550
12#Channel 11$Channel 11unsignedInt 0…2550
13#Channel 12$Channel 12unsignedInt 0…2550
14#Channel 13$Channel 13unsignedInt 0…2550
15#Channel 14$Channel 14unsignedInt 0…2550
16#Channel 15$Channel 15unsignedInt 0…2550
17#Channel 16$Channel 16unsignedInt 0…2550
UCC_ENDunsignedInt 0…65535453
ApplicationlistDevice settings
Parameter SizeunsignedInt 0…6553511
usApplicationVersionunsignedInt 0…655351
Sending and switching delay after KNX voltage recoveryunsignedInt 2…602
Value after sending and switching delay has expiredlistLast value received
Telegram rate limitunsignedInt 0…10
Maximum number of sent telegramsunsignedInt 0…10020
In periodunsignedInt 0…591
Time between read requests after device startupunsignedInt 500…5000500
Enable Group Object "In operation"listNo
Sending cycletime600
Enable time group objects for setting of device timelistNo
Request date/time via group objectunsignedInt 0…10
Polling pause for MP-Bus devices that do not respondunsignedInt 1…25530
Enable Group Object "Request status values"unsignedInt 0…10
Config lengthunsignedInt 0…655350
ApplicationlistDeactivated
Parameter SizeunsignedInt 0…6553551
ApplicationVersionunsignedInt 0…655351
Devicelist
Parameter settingunsignedInt 0…10
Product picturepicture
MP-Bus addresslist-/-
Serial numbertext00000-00000-000-000
Cyclical monitoring of setpoint and override controlunsignedInt 0…10
Monitoring timetime900
CalcParamunsignedInt 0…2550
Actuator position after cyclical monitoring time has elapsedlistUnchanged
DPT of absolute positionlistRotation angle
Send status valueslistOn change
Value difference for sending status valuesunsignedInt 0…3010
Value difference for sending status valuesunsignedInt 0…25526
DPT for Group Objects "Status Absolute flow rate", "Status Nominal flow rate"list2 bytes (DPT 9.009)
Valve typelist2-way/3-way valve
Heating/cooling inputlistOne common Group Object
6-way valve settingpicture
Lowest input value for cooling control value 0unsignedInt 30…6033
1: Lowest input value for cooling output 0unsignedInt 0…25584
Highest input value for heating control value 0unsignedInt 40…7066
2: Highest input value for heatling output 0unsignedInt 0…255168
Swap heating and coolingunsignedInt 0…10
Sensor typelistNo sensor
Output sensor valuelistVoltage (DPT 9.020)
Output sensor valuelistDPT 9.007
Output sensor valuelistNormal
Minimum sensor valueunsignedInt 0…320000
Minimum output valueunsignedInt 0…1000
Minimum output valueunsignedInt 0…2550
Maximum sensor valueunsignedInt 0…3200032000
Maximum output valueunsignedInt 0…100100
Maximum output valueunsignedInt 0…255255
Send sensor valueslistOn change
Value difference for sending sensor valuesunsignedInt 1…65000100
Value difference for sending sensor valuesunsignedInt 1…10010
Value difference for sending sensor valuesunsignedInt 0…25526
Value difference for sending sensor valuesunsignedInt 1…650001
Value difference for sending sensor valuesunsignedInt 1…500100
Value difference for sending sensor valuesunsignedInt 1…305
Value difference for sending sensor valuesfloat 0.5…100.5
Cyclical monitoring of control value and override controlunsignedInt 0…10
Cyclical monitoring of control valueunsignedInt 0…10
Parameter SizeunsignedInt 0…6553549
Control vialistMP-Bus
VRU typelistVRU-D3-BAC/VRU-M1-BAC
ApplicationlistFlow control
ApplicationlistRoom pressure control
Control modelistPosition control
Room pressure cascadelistDisabled
Room pressure cascadelistEnabled (fast)
Operating modelistPositive differential pressure
EnabledunsignedInt 0…11
DisabledunsignedInt 0…11
Sensor typelistAnalog input signal
Sensor typelistActive sensor
Parameter SizeunsignedInt 0…6553587
Operating modelistFlow control
Activate Delta-T ManagerunsignedInt 0…10
Default value Delta-Tfloat 0.1…4010
Send values of Group Objects "Status Total energy cooling" "Status Total energy heating"listOn change
Value difference for sending status valuesunsignedInt 1…10001
Send temperature valueslistOn change
Value difference for sending valuefloat 0.1…101
Send position control valueslistOn change
Value difference for sending valueunsignedInt 0…205
Value is sent from a change ofunsignedInt 0…25513
Send flow rateslistOn change
Output relative value in relation tolistV'max (0...150%)
Send value of Group Object "Status Accumulated volume"listOn change
Value difference for sending valuefloat 0.1…1000001
Send power valueslistOn change
Output relative value in relation tolistPmax (0...300%)
Send differential pressure valueslistOn change
Sending cycletime3600
Display relative value in relation tolistV'max (0...150%)
Display relative value in relation tolistPmax (0...300%)
Send differential water pressure valueslistNo, update only
Value is sent from a change ofunsignedInt 0…205
Parameter SizeunsignedInt 0…6553563
Enable Group Object "Binary input"unsignedInt 0…10
Invert Group Object "Binary input"unsignedInt 0…10
Temperature displaylistStatus Room temperature
Basic setpointfloat 16…3421
Temperature setpoint indicatorlistAbsolute
Temperature setpoint rangeunsignedInt 0…53
Offset temperaturefloat -14.5…14.50
Send value of Group Object "Status Room temperature"listOn change
Value difference for sending valuefloat 0.5…100.5
Enable Group Object "CO2 value"unsignedInt 0…10
Send value of Group Object "CO2 value"listOn change
Value difference for sending valueunsignedInt 1…1000100
Display air qualityunsignedInt 0…10
CO2 threshold OK/warningunsignedInt 600…12491000
CO2 threshold warning/alarmunsignedInt 1250…20001500
Display CO2 valueunsignedInt 0…10
Offset CO2 valuesignedInt -500…5000
Enable Group Object "Status Relative humidity"unsignedInt 0…10
Send value of Group Object "Status Relative humidity"listOn change
Value difference for sending valueunsignedInt 1…305
Display humidityunsignedInt 0…10
Humidity offsetsignedInt -20…200
Enable Group Object "Dew point temperature"unsignedInt 0…10
Send value of Group Object "Dew point temperature"listOn change
Enable fan controlunsignedInt 0…10
Number of fan speedslist0…2
Enable fan automatic modeunsignedInt 0…10
Receive status Heating/coolinglistDeactivated
Enable ECO mode buttonlistDeactivated
Enable On/Off buttonlistDeactivated
Enable Boost mode buttonunsignedInt 0…10

Application program: KNX/MP-Bus Controller/1.0 5.0

Application number$B12A
Version5.0
Mask versionMV-07B0 (System B)
KNX Data SecureYes
Minimum ETS version5.0
Parameters0
Group objects0
Group objects (0)
NoNameFunctionSizeDPTFlags
Parameters (0)
ParameterTypeDefault

Version history

ApplicationApp noFingerprintFirst seenSizeFile
KNX/MP-Bus Controller/1.0 1.0 latest$B12A9D3B2026-11-253.0 MBDownload

About this file

This is the official ETS product database for the ABB AG - STOTZ-KONTAKT MPG/S8.1.1 KNX/MP-Bus Controller (2CDG 110 311 R0011), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.

More from ABB AG - STOTZ-KONTAKT

All ABB AG - STOTZ-KONTAKT products