ABB AG - STOTZ-KONTAKT 2CDG 110 308 R0011 US/U2.3 Universal Interface, 2-fold, FM

US/U2.3 Universal Interface, 2-fold, FM 2CDG 110 308 R0011

ABB AG - STOTZ-KONTAKT · Order number 2CDG 110 308 R0011 · Standard Inputs › Universal Interfaces

Download .knxprod Universal Interface, 2f/1.0 1.0 · 584 KB

Product

ManufacturerABB AG - STOTZ-KONTAKT
Product nameUS/U2.3 Universal Interface, 2-fold, FM
Order number2CDG 110 308 R0011
HardwareUS/U2.3 Universal Interface, 2-fold, FM
MediumTwisted Pair
Bus current (mA)10
Rail mountedNo
RegistrationRegistered · 2024-10-01
Languagesen-US, de-DE, es-ES, fr-FR, it-IT, nl-NL, pl-PL, ru-RU
Catalog entryM-0002_H-2CDG.20110.20308.20R0011-1_HP-B123-10-2562-B123-20-C8A6_CI-2CDG.20110.20308.20R0011-1
Fingerprint2562
SHA-256e716fdb94832c7ac8f2bbd173bacfd891aeac8d97b8d9e8e9d7a3d9f9fa75f00
First seen2026-11-25
Markets59 markets

Application program: Universal Interface, 2f/1.0 1.0

Application number$B123
Version1.0
Mask versionMV-07B0 (System B)
KNX Data SecureYes
Minimum ETS version5.0
Parameters3148
Group objects313
Group objects (313)
NoNameFunctionSizeDPTFlags
1Central – General: In operation1 Bit1.2 booleanCRT
10Central – Date/time: Set time3 Bytes10.1 time of dayCW
10Central – Date/time: Set date/time8 Bytes19.1 date timeCW
11Central – Date/time: Set date3 Bytes11.1 dateCW
12Central – Date/time: Request date/time1 Bit1.17 triggerCT
13Logic – Connection 1: Connection A1 Bit1.2 booleanCWTU
14Logic – Connection 1: Connection B1 Bit1.2 booleanCWTU
15Logic – Result 1: Status Result1 Bit1.2 booleanCRT
16Logic – Block 1: Block logic1 Bit1.3 enableCW
17Logic – Request 1: Request status values1 Bit1.17 triggerCW
18Logic – Connection 2: Connection A1 Bit1.2 booleanCWTU
19Logic – Connection 2: Connection B1 Bit1.2 booleanCWTU
20Logic – Result 2: Status Result1 Bit1.2 booleanCRT
21Logic – Block 2: Block logic1 Bit1.3 enableCW
22Logic – Request 2: Request status values1 Bit1.17 triggerCW
23Logic – Connection 3: Connection A1 Bit1.2 booleanCWTU
24Logic – Connection 3: Connection B1 Bit1.2 booleanCWTU
25Logic – Result 3: Status Result1 Bit1.2 booleanCRT
26Logic – Block 3: Block logic1 Bit1.3 enableCW
27Logic – Request 3: Request status values1 Bit1.17 triggerCW
28Logic – Connection 4: Connection A1 Bit1.2 booleanCWTU
29Logic – Connection 4: Connection B1 Bit1.2 booleanCWTU
30Logic – Result 4: Status Result1 Bit1.2 booleanCRT
31Logic – Block 4: Block logic1 Bit1.3 enableCW
32Logic – Request 4: Request status values1 Bit1.17 triggerCW
33Channel A – Switch: {{0}}Switch1 Bit1.1 switchCWTU
33Channel A+B – Switch: {{0}}Switch1 Bit1.1 switchCWTU
33Channel A – Blind/shutter: {{0}}Up/down1 Bit1.8 up/downCWTU
33Channel A+B – Blind/shutter: {{0}}Up/down1 Bit1.8 up/downCWTU
33Channel A – Switch/dim: {{0}}Dimming4 Bit3.7 dimming controlCT
33Channel A+B – Switch/dim: {{0}}Dimming4 Bit3.7 dimming controlCT
33Channel A – Scene: {{0}}Scene 1…641 Byte18.1 scene controlCT
33Channel A – Send value: {{0}}Value 1: Switch1 Bit1.1 switchCWTU
33Channel A – Send value: {{0}}Value 1: Percent1 Byte5.1 percentage (0..100%)CWTU
33Channel A – Send value: {{0}}Value 1: Forced operation2 Bit2.1 switch controlCRWT
33Channel A – Send value: {{0}}Value 1: Temperature2 Bytes9.1 temperature (°C)CWTU
33Channel A – Send value: {{0}}Value 1: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
33Channel A – Send value: {{0}}Value 1: HVAC mode1 Byte20.102 HVAC modeCWTU
33Channel A – Send value: {{0}}Value 1: 1 byte1 Byte5.10 counter pulses (0..255)CWTU
33Channel A – Send value: {{0}}Value 1: 1 byte signed1 Byte6.10 counter pulses (-128..127)CWTU
33Channel A – Send value: {{0}}Value 1: 2 bytes2 Bytes7.1 pulsesCWTU
33Channel A – Send value: {{0}}Value 1: 2 bytes signed2 Bytes8.1 pulses differenceCWTU
33Channel A – Send value: {{0}}Value 1: 4 bytes4 Bytes12.1 counter pulses (unsigned)CWTU
33Channel A – Fault indicator/logic input: {{0}}Status Fault1 Bit1.11 stateCRWT
33Channel A – Switching sequence: {{0}}Value 1: Switch1 Bit1.1 switchCWTU
33Channel A – Switching sequence: {{0}}Value 1: Percent1 Byte5.1 percentage (0..100%)CWTU
33Channel A – Switching sequence: {{0}}Value 1: Byte1 Byte5.10 counter pulses (0..255)CWTU
33Channel A – Switching sequence: {{0}}Value 1: Scene1 Byte18.1 scene controlCWTU
33Channel A – Switching sequence: {{0}}Value 1: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
33Channel A – Switching sequence: {{0}}Value 1: HVAC mode1 Byte20.102 HVAC modeCWTU
33Channel A+B – Switching sequence: {{0}}Value 1: Switch1 Bit1.1 switchCWTU
33Channel A+B – Switching sequence: {{0}}Value 1: Percent1 Byte5.1 percentage (0..100%)CWTU
33Channel A+B – Switching sequence: {{0}}Value 1: Byte1 Byte5.10 counter pulses (0..255)CWTU
33Channel A+B – Switching sequence: {{0}}Value 1: Scene1 Byte18.1 scene controlCWTU
33Channel A+B – Switching sequence: {{0}}Value 1: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
33Channel A+B – Switching sequence: {{0}}Value 1: HVAC mode1 Byte20.102 HVAC modeCWTU
33Channel A – Pulse counter 1: {{0}}Counter value1 Byte6.10 counter pulses (-128..127)CRT
33Channel A – Pulse counter 1: {{0}}Counter value1 Byte5.10 counter pulses (0..255)CRT
33Channel A – Pulse counter 1: {{0}}Counter value2 Bytes8.1 pulses differenceCRT
33Channel A – Pulse counter 1: {{0}}Counter value2 Bytes7.1 pulsesCRT
33Channel A – Pulse counter 1: {{0}}Counter value4 Bytes13.1 counter pulses (signed)CRT
33Channel A – Pulse counter 1: {{0}}Counter value4 Bytes12.1 counter pulses (unsigned)CRT
33Channel A – LED control: {{0}}Switch1 Bit1.1 switchCW
34Channel A – Switch: {{0}}Block1 Bit1.3 enableCW
34Channel A+B – Switch: {{0}}Block1 Bit1.3 enableCW
34Channel A – Blind/shutter: {{0}}Step/stop1 Bit1.7 stepCWTU
34Channel A – Blind/shutter: {{0}}Stop1 Bit1.17 triggerCWTU
34Channel A+B – Blind/shutter: {{0}}Step/stop1 Bit1.7 stepCWTU
34Channel A+B – Blind/shutter: {{0}}Stop1 Bit1.17 triggerCWTU
34Channel A – Switch/dim: {{0}}Switch1 Bit1.1 switchCWTU
34Channel A+B – Switch/dim: {{0}}Switch1 Bit1.1 switchCWTU
34Channel A – Scene: {{0}}Block1 Bit1.3 enableCW
34Channel A – Send value: {{0}}Value 2: Switch1 Bit1.1 switchCWTU
34Channel A – Send value: {{0}}Value 2: Percent1 Byte5.1 percentage (0..100%)CWTU
34Channel A – Send value: {{0}}Value 2: Forced operation2 Bit2.1 switch controlCRWT
34Channel A – Send value: {{0}}Value 2: Temperature2 Bytes9.1 temperature (°C)CWTU
34Channel A – Send value: {{0}}Value 2: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
34Channel A – Send value: {{0}}Value 2: HVAC mode1 Byte20.102 HVAC modeCWTU
34Channel A – Send value: {{0}}Value 2: 1 byte1 Byte5.10 counter pulses (0..255)CWTU
34Channel A – Send value: {{0}}Value 2: 1 byte signed1 Byte6.10 counter pulses (-128..127)CWTU
34Channel A – Send value: {{0}}Value 2: 2 bytes2 Bytes7.1 pulsesCWTU
34Channel A – Send value: {{0}}Value 2: 2 bytes signed2 Bytes8.1 pulses differenceCWTU
34Channel A – Send value: {{0}}Value 2: 4 bytes4 Bytes12.1 counter pulses (unsigned)CWTU
34Channel A – Fault indicator/logic input: {{0}}Block1 Bit1.3 enableCW
34Channel A – Switching sequence: {{0}}Value 2: Switch1 Bit1.1 switchCWTU
34Channel A – Switching sequence: {{0}}Value 2: Percent1 Byte5.1 percentage (0..100%)CWTU
34Channel A – Switching sequence: {{0}}Value 2: Byte1 Byte5.10 counter pulses (0..255)CWTU
34Channel A – Switching sequence: {{0}}Value 2: Scene1 Byte18.1 scene controlCWTU
34Channel A – Switching sequence: {{0}}Value 2: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
34Channel A – Switching sequence: {{0}}Value 2: HVAC mode1 Byte20.102 HVAC modeCWTU
34Channel A+B – Switching sequence: {{0}}Value 2: Switch1 Bit1.1 switchCWTU
34Channel A+B – Switching sequence: {{0}}Value 2: Percent1 Byte5.1 percentage (0..100%)CWTU
34Channel A+B – Switching sequence: {{0}}Value 2: Byte1 Byte5.10 counter pulses (0..255)CWTU
34Channel A+B – Switching sequence: {{0}}Value 2: Scene1 Byte18.1 scene controlCWTU
34Channel A+B – Switching sequence: {{0}}Value 2: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
34Channel A+B – Switching sequence: {{0}}Value 2: HVAC mode1 Byte20.102 HVAC modeCWTU
34Channel A – Pulse counter 1: {{0}}Reset counter value1 Bit1.15 resetCW
34Channel A – LED control: {{0}}Flashing1 Bit1.1 switchCW
35Channel A – Switch: {{0}}Switch 21 Bit1.1 switchCWTU
35Channel A+B – Blind/shutter: {{0}}Status Upper end position1 Bit1.2 booleanCWU
35Channel A+B – Switch/dim: {{0}}Block1 Bit1.3 enableCW
35Channel A – Send value: {{0}}Value 3: Switch1 Bit1.1 switchCWTU
35Channel A – Send value: {{0}}Value 3: Percent1 Byte5.1 percentage (0..100%)CWTU
35Channel A – Send value: {{0}}Value 3: Forced operation2 Bit2.1 switch controlCWTU
35Channel A – Send value: {{0}}Value 3: Temperature2 Bytes9.1 temperature (°C)CWTU
35Channel A – Send value: {{0}}Value 3: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
35Channel A – Send value: {{0}}Value 3: HVAC mode1 Byte20.102 HVAC modeCWTU
35Channel A – Send value: {{0}}Value 3: 1 byte1 Byte5.10 counter pulses (0..255)CWTU
35Channel A – Send value: {{0}}Value 3: 1 byte signed1 Byte6.10 counter pulses (-128..127)CWTU
35Channel A – Send value: {{0}}Value 3: 2 bytes2 Bytes7.1 pulsesCWTU
35Channel A – Send value: {{0}}Value 3: 2 bytes signed2 Bytes8.1 pulses differenceCWTU
35Channel A – Send value: {{0}}Value 3: 4 bytes4 Bytes12.1 counter pulses (unsigned)CWTU
35Channel A – Fault indicator/logic input: {{0}}Request status Fault1 Bit1.17 triggerCW
35Channel A – Switching sequence: {{0}}Value 3: Switch1 Bit1.1 switchCWTU
35Channel A – Switching sequence: {{0}}Value 3: Percent1 Byte5.1 percentage (0..100%)CWTU
35Channel A – Switching sequence: {{0}}Value 3: Byte1 Byte5.10 counter pulses (0..255)CWTU
35Channel A – Switching sequence: {{0}}Value 3: Scene1 Byte18.1 scene controlCWTU
35Channel A – Switching sequence: {{0}}Value 3: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
35Channel A – Switching sequence: {{0}}Value 3: HVAC mode1 Byte20.102 HVAC modeCWTU
35Channel A+B – Switching sequence: {{0}}Value 3: Switch1 Bit1.1 switchCWTU
35Channel A+B – Switching sequence: {{0}}Value 3: Percent1 Byte5.1 percentage (0..100%)CWTU
35Channel A+B – Switching sequence: {{0}}Value 3: Byte1 Byte5.10 counter pulses (0..255)CWTU
35Channel A+B – Switching sequence: {{0}}Value 3: Scene1 Byte18.1 scene controlCWTU
35Channel A+B – Switching sequence: {{0}}Value 3: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
35Channel A+B – Switching sequence: {{0}}Value 3: HVAC mode1 Byte20.102 HVAC modeCWTU
35Channel A – Pulse counter 1: {{0}}Request counter value1 Bit1.17 triggerCW
35Channel A – LED control: {{0}}Permanent On1 Bit1.3 enableCW
36Channel A – Switch: {{0}}Block 21 Bit1.3 enableCW
36Channel A – Blind/shutter: {{0}}Status Upper end position1 Bit1.2 booleanCWU
36Channel A+B – Blind/shutter: {{0}}Status Lower end position1 Bit1.2 booleanCWU
36Channel A – Switch/dim: {{0}}Block1 Bit1.3 enableCW
36Channel A – Send value: {{0}}Value 4: Switch1 Bit1.1 switchCWTU
36Channel A – Send value: {{0}}Value 4: Percent1 Byte5.1 percentage (0..100%)CWTU
36Channel A – Send value: {{0}}Value 4: Forced operation2 Bit2.1 switch controlCWTU
36Channel A – Send value: {{0}}Value 4: Temperature2 Bytes9.1 temperature (°C)CWTU
36Channel A – Send value: {{0}}Value 4: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
36Channel A – Send value: {{0}}Value 4: HVAC mode1 Byte20.102 HVAC modeCWTU
36Channel A – Send value: {{0}}Value 4: 1 byte1 Byte5.10 counter pulses (0..255)CWTU
36Channel A – Send value: {{0}}Value 4: 1 byte signed1 Byte6.10 counter pulses (-128..127)CWTU
36Channel A – Send value: {{0}}Value 4: 2 bytes2 Bytes7.1 pulsesCWTU
36Channel A – Send value: {{0}}Value 4: 2 bytes signed2 Bytes8.1 pulses differenceCWTU
36Channel A – Send value: {{0}}Value 4: 4 bytes4 Bytes12.1 counter pulses (unsigned)CWTU
36Channel A – Switching sequence: {{0}}Value 4: Switch1 Bit1.1 switchCWTU
36Channel A – Switching sequence: {{0}}Value 4: Percent1 Byte5.1 percentage (0..100%)CWTU
36Channel A – Switching sequence: {{0}}Value 4: Byte1 Byte5.10 counter pulses (0..255)CWTU
36Channel A – Switching sequence: {{0}}Value 4: Scene1 Byte18.1 scene controlCWTU
36Channel A – Switching sequence: {{0}}Value 4: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
36Channel A – Switching sequence: {{0}}Value 4: HVAC mode1 Byte20.102 HVAC modeCWTU
36Channel A+B – Switching sequence: {{0}}Value 4: Switch1 Bit1.1 switchCWTU
36Channel A+B – Switching sequence: {{0}}Value 4: Percent1 Byte5.1 percentage (0..100%)CWTU
36Channel A+B – Switching sequence: {{0}}Value 4: Byte1 Byte5.10 counter pulses (0..255)CWTU
36Channel A+B – Switching sequence: {{0}}Value 4: Scene1 Byte18.1 scene controlCWTU
36Channel A+B – Switching sequence: {{0}}Value 4: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
36Channel A+B – Switching sequence: {{0}}Value 4: HVAC mode1 Byte20.102 HVAC modeCWTU
36Channel A – Pulse counter 1: {{0}}Limit value reached1 Bit1.2 booleanCRT
36Channel A – LED control: {{0}}Status1 Bit1.11 stateCRT
37Channel A – Blind/shutter: {{0}}Status Lower end position1 Bit1.2 booleanCWU
37Channel A+B – Blind/shutter: {{0}}Status Move1 Bit1.2 booleanCWU
37Channel A – Send value: {{0}}Block1 Bit1.3 enableCWTU
37Channel A – Switching sequence: {{0}}Value 5: Switch1 Bit1.1 switchCWTU
37Channel A – Switching sequence: {{0}}Value 5: Percent1 Byte5.1 percentage (0..100%)CWTU
37Channel A – Switching sequence: {{0}}Value 5: Byte1 Byte5.10 counter pulses (0..255)CWTU
37Channel A – Switching sequence: {{0}}Value 5: Scene1 Byte18.1 scene controlCWTU
37Channel A – Switching sequence: {{0}}Value 5: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
37Channel A – Switching sequence: {{0}}Value 5: HVAC mode1 Byte20.102 HVAC modeCWTU
37Channel A+B – Switching sequence: {{0}}Value 5: Switch1 Bit1.1 switchCWTU
37Channel A+B – Switching sequence: {{0}}Value 5: Percent1 Byte5.1 percentage (0..100%)CWTU
37Channel A+B – Switching sequence: {{0}}Value 5: Byte1 Byte5.10 counter pulses (0..255)CWTU
37Channel A+B – Switching sequence: {{0}}Value 5: Scene1 Byte18.1 scene controlCWTU
37Channel A+B – Switching sequence: {{0}}Value 5: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
37Channel A+B – Switching sequence: {{0}}Value 5: HVAC mode1 Byte20.102 HVAC modeCWTU
37Channel A – Pulse counter 2: {{0}}Counter value1 Byte6.10 counter pulses (-128..127)CRT
37Channel A – Pulse counter 2: {{0}}Counter value1 Byte5.10 counter pulses (0..255)CRT
37Channel A – Pulse counter 2: {{0}}Counter value2 Bytes8.1 pulses differenceCRT
37Channel A – Pulse counter 2: {{0}}Counter value2 Bytes7.1 pulsesCRT
37Channel A – Pulse counter 2: {{0}}Counter value4 Bytes13.1 counter pulses (signed)CRT
37Channel A – Pulse counter 2: {{0}}Counter value4 Bytes12.1 counter pulses (unsigned)CRT
38Channel A – Blind/shutter: {{0}}Status Move1 Bit1.2 booleanCWU
38Channel A+B – Blind/shutter: {{0}}Block1 Bit1.3 enableCW
38Channel A – Switching sequence: {{0}}Number of operations1 Byte5.10 counter pulses (0..255)CWTU
38Channel A+B – Switching sequence: {{0}}Number of operations1 Byte5.10 counter pulses (0..255)CWTU
38Channel A – Pulse counter 2: {{0}}Reset counter value1 Bit1.15 resetCW
39Channel A – Blind/shutter: {{0}}Block1 Bit1.3 enableCW
39Channel A – Switching sequence: {{0}}Reset switching sequence1 Bit1.17 triggerCW
39Channel A+B – Switching sequence: {{0}}Reset switching sequence1 Bit1.17 triggerCW
39Channel A – Pulse counter 2: {{0}}Request counter value1 Bit1.17 triggerCW
40Channel A – Switching sequence: {{0}}Next/previous step1 Bit1.7 stepCW
40Channel A+B – Switching sequence: {{0}}Next/previous step1 Bit1.7 stepCW
40Channel A – Pulse counter 2: {{0}}Limit value reached1 Bit1.2 booleanCRT
41Channel A – Switching sequence: {{0}}Block1 Bit1.3 enableCW
41Channel A+B – Switching sequence: {{0}}Block1 Bit1.3 enableCW
41Channel A – Pulse counter: {{0}}Block1 Bit1.3 enableCW
42Channel B – Switch: {{0}}Switch1 Bit1.1 switchCWTU
42Channel B – Blind/shutter: {{0}}Up/down1 Bit1.8 up/downCWTU
42Channel B – Switch/dim: {{0}}Dimming4 Bit3.7 dimming controlCT
42Channel B – Scene: {{0}}Scene 1…641 Byte18.1 scene controlCT
42Channel B – Send value: {{0}}Value 1: Switch1 Bit1.1 switchCWTU
42Channel B – Send value: {{0}}Value 1: Percent1 Byte5.1 percentage (0..100%)CWTU
42Channel B – Send value: {{0}}Value 1: Forced operation2 Bit2.1 switch controlCRWT
42Channel B – Send value: {{0}}Value 1: Temperature2 Bytes9.1 temperature (°C)CWTU
42Channel B – Send value: {{0}}Value 1: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
42Channel B – Send value: {{0}}Value 1: HVAC mode1 Byte20.102 HVAC modeCWTU
42Channel B – Send value: {{0}}Value 1: 1 byte1 Byte5.10 counter pulses (0..255)CWTU
42Channel B – Send value: {{0}}Value 1: 1 byte signed1 Byte6.10 counter pulses (-128..127)CWTU
42Channel B – Send value: {{0}}Value 1: 2 bytes2 Bytes7.1 pulsesCWTU
42Channel B – Send value: {{0}}Value 1: 2 bytes signed2 Bytes8.1 pulses differenceCWTU
42Channel B – Send value: {{0}}Value 1: 4 bytes4 Bytes12.1 counter pulses (unsigned)CWTU
42Channel B – Fault indicator/logic input: {{0}}Status Fault1 Bit1.11 stateCRWT
42Channel B – Switching sequence: {{0}}Value 1: Switch1 Bit1.1 switchCWTU
42Channel B – Switching sequence: {{0}}Value 1: Percent1 Byte5.1 percentage (0..100%)CWTU
42Channel B – Switching sequence: {{0}}Value 1: Byte1 Byte5.10 counter pulses (0..255)CWTU
42Channel B – Switching sequence: {{0}}Value 1: Scene1 Byte18.1 scene controlCWTU
42Channel B – Switching sequence: {{0}}Value 1: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
42Channel B – Switching sequence: {{0}}Value 1: HVAC mode1 Byte20.102 HVAC modeCWTU
42Channel B – Pulse counter 1: {{0}}Counter value1 Byte6.10 counter pulses (-128..127)CRT
42Channel B – Pulse counter 1: {{0}}Counter value1 Byte5.10 counter pulses (0..255)CRT
42Channel B – Pulse counter 1: {{0}}Counter value2 Bytes8.1 pulses differenceCRT
42Channel B – Pulse counter 1: {{0}}Counter value2 Bytes7.1 pulsesCRT
42Channel B – Pulse counter 1: {{0}}Counter value4 Bytes13.1 counter pulses (signed)CRT
42Channel B – Pulse counter 1: {{0}}Counter value4 Bytes12.1 counter pulses (unsigned)CRT
42Channel B – LED control: {{0}}Switch1 Bit1.1 switchCW
43Channel B – Switch: {{0}}Block1 Bit1.3 enableCW
43Channel B – Blind/shutter: {{0}}Step/stop1 Bit1.7 stepCWTU
43Channel B – Blind/shutter: {{0}}Stop1 Bit1.17 triggerCWTU
43Channel B – Switch/dim: {{0}}Switch1 Bit1.1 switchCWTU
43Channel B – Scene: {{0}}Block1 Bit1.3 enableCW
43Channel B – Send value: {{0}}Value 2: Switch1 Bit1.1 switchCWTU
43Channel B – Send value: {{0}}Value 2: Percent1 Byte5.1 percentage (0..100%)CWTU
43Channel B – Send value: {{0}}Value 2: Forced operation2 Bit2.1 switch controlCRWT
43Channel B – Send value: {{0}}Value 2: Temperature2 Bytes9.1 temperature (°C)CWTU
43Channel B – Send value: {{0}}Value 2: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
43Channel B – Send value: {{0}}Value 2: HVAC mode1 Byte20.102 HVAC modeCWTU
43Channel B – Send value: {{0}}Value 2: 1 byte1 Byte5.10 counter pulses (0..255)CWTU
43Channel B – Send value: {{0}}Value 2: 1 byte signed1 Byte6.10 counter pulses (-128..127)CWTU
43Channel B – Send value: {{0}}Value 2: 2 bytes2 Bytes7.1 pulsesCWTU
43Channel B – Send value: {{0}}Value 2: 2 bytes signed2 Bytes8.1 pulses differenceCWTU
43Channel B – Send value: {{0}}Value 2: 4 bytes4 Bytes12.1 counter pulses (unsigned)CWTU
43Channel B – Fault indicator/logic input: {{0}}Block1 Bit1.3 enableCW
43Channel B – Switching sequence: {{0}}Value 2: Switch1 Bit1.1 switchCWTU
43Channel B – Switching sequence: {{0}}Value 2: Percent1 Byte5.1 percentage (0..100%)CWTU
43Channel B – Switching sequence: {{0}}Value 2: Byte1 Byte5.10 counter pulses (0..255)CWTU
43Channel B – Switching sequence: {{0}}Value 2: Scene1 Byte18.1 scene controlCWTU
43Channel B – Switching sequence: {{0}}Value 2: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
43Channel B – Switching sequence: {{0}}Value 2: HVAC mode1 Byte20.102 HVAC modeCWTU
43Channel B – Pulse counter 1: {{0}}Reset counter value1 Bit1.15 resetCW
43Channel B – LED control: {{0}}Flashing1 Bit1.1 switchCW
44Channel B – Switch: {{0}}Switch 21 Bit1.1 switchCWTU
44Channel B – Send value: {{0}}Value 3: Switch1 Bit1.1 switchCWTU
44Channel B – Send value: {{0}}Value 3: Percent1 Byte5.1 percentage (0..100%)CWTU
44Channel B – Send value: {{0}}Value 3: Forced operation2 Bit2.1 switch controlCWTU
44Channel B – Send value: {{0}}Value 3: Temperature2 Bytes9.1 temperature (°C)CWTU
44Channel B – Send value: {{0}}Value 3: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
44Channel B – Send value: {{0}}Value 3: HVAC mode1 Byte20.102 HVAC modeCWTU
44Channel B – Send value: {{0}}Value 3: 1 byte1 Byte5.10 counter pulses (0..255)CWTU
44Channel B – Send value: {{0}}Value 3: 1 byte signed1 Byte6.10 counter pulses (-128..127)CWTU
44Channel B – Send value: {{0}}Value 3: 2 bytes2 Bytes7.1 pulsesCWTU
44Channel B – Send value: {{0}}Value 3: 2 bytes signed2 Bytes8.1 pulses differenceCWTU
44Channel B – Send value: {{0}}Value 3: 4 bytes4 Bytes12.1 counter pulses (unsigned)CWTU
44Channel B – Fault indicator/logic input: {{0}}Request status Fault1 Bit1.17 triggerCW
44Channel B – Switching sequence: {{0}}Value 3: Switch1 Bit1.1 switchCWTU
44Channel B – Switching sequence: {{0}}Value 3: Percent1 Byte5.1 percentage (0..100%)CWTU
44Channel B – Switching sequence: {{0}}Value 3: Byte1 Byte5.10 counter pulses (0..255)CWTU
44Channel B – Switching sequence: {{0}}Value 3: Scene1 Byte18.1 scene controlCWTU
44Channel B – Switching sequence: {{0}}Value 3: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
44Channel B – Switching sequence: {{0}}Value 3: HVAC mode1 Byte20.102 HVAC modeCWTU
44Channel B – Pulse counter 1: {{0}}Request counter value1 Bit1.17 triggerCW
44Channel B – LED control: {{0}}Permanent On1 Bit1.3 enableCW
45Channel B – Switch: {{0}}Block 21 Bit1.3 enableCW
45Channel B – Blind/shutter: {{0}}Status Upper end position1 Bit1.2 booleanCWU
45Channel B – Switch/dim: {{0}}Block1 Bit1.3 enableCW
45Channel B – Send value: {{0}}Value 4: Switch1 Bit1.1 switchCWTU
45Channel B – Send value: {{0}}Value 4: Percent1 Byte5.1 percentage (0..100%)CWTU
45Channel B – Send value: {{0}}Value 4: Forced operation2 Bit2.1 switch controlCWTU
45Channel B – Send value: {{0}}Value 4: Temperature2 Bytes9.1 temperature (°C)CWTU
45Channel B – Send value: {{0}}Value 4: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
45Channel B – Send value: {{0}}Value 4: HVAC mode1 Byte20.102 HVAC modeCWTU
45Channel B – Send value: {{0}}Value 4: 1 byte1 Byte5.10 counter pulses (0..255)CWTU
45Channel B – Send value: {{0}}Value 4: 1 byte signed1 Byte6.10 counter pulses (-128..127)CWTU
45Channel B – Send value: {{0}}Value 4: 2 bytes2 Bytes7.1 pulsesCWTU
45Channel B – Send value: {{0}}Value 4: 2 bytes signed2 Bytes8.1 pulses differenceCWTU
45Channel B – Send value: {{0}}Value 4: 4 bytes4 Bytes12.1 counter pulses (unsigned)CWTU
45Channel B – Switching sequence: {{0}}Value 4: Switch1 Bit1.1 switchCWTU
45Channel B – Switching sequence: {{0}}Value 4: Percent1 Byte5.1 percentage (0..100%)CWTU
45Channel B – Switching sequence: {{0}}Value 4: Byte1 Byte5.10 counter pulses (0..255)CWTU
45Channel B – Switching sequence: {{0}}Value 4: Scene1 Byte18.1 scene controlCWTU
45Channel B – Switching sequence: {{0}}Value 4: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
45Channel B – Switching sequence: {{0}}Value 4: HVAC mode1 Byte20.102 HVAC modeCWTU
45Channel B – Pulse counter 1: {{0}}Limit value reached1 Bit1.2 booleanCRT
45Channel B – LED control: {{0}}Status1 Bit1.11 stateCRT
46Channel B – Blind/shutter: {{0}}Status Lower end position1 Bit1.2 booleanCWU
46Channel B – Send value: {{0}}Block1 Bit1.3 enableCWTU
46Channel B – Switching sequence: {{0}}Value 5: Switch1 Bit1.1 switchCWTU
46Channel B – Switching sequence: {{0}}Value 5: Percent1 Byte5.1 percentage (0..100%)CWTU
46Channel B – Switching sequence: {{0}}Value 5: Byte1 Byte5.10 counter pulses (0..255)CWTU
46Channel B – Switching sequence: {{0}}Value 5: Scene1 Byte18.1 scene controlCWTU
46Channel B – Switching sequence: {{0}}Value 5: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
46Channel B – Switching sequence: {{0}}Value 5: HVAC mode1 Byte20.102 HVAC modeCWTU
46Channel B – Pulse counter 2: {{0}}Counter value1 Byte6.10 counter pulses (-128..127)CRT
46Channel B – Pulse counter 2: {{0}}Counter value1 Byte5.10 counter pulses (0..255)CRT
46Channel B – Pulse counter 2: {{0}}Counter value2 Bytes8.1 pulses differenceCRT
46Channel B – Pulse counter 2: {{0}}Counter value2 Bytes7.1 pulsesCRT
46Channel B – Pulse counter 2: {{0}}Counter value4 Bytes13.1 counter pulses (signed)CRT
46Channel B – Pulse counter 2: {{0}}Counter value4 Bytes12.1 counter pulses (unsigned)CRT
47Channel B – Blind/shutter: {{0}}Status Move1 Bit1.2 booleanCWU
47Channel B – Switching sequence: {{0}}Number of operations1 Byte5.10 counter pulses (0..255)CWTU
47Channel B – Pulse counter 2: {{0}}Reset counter value1 Bit1.15 resetCW
48Channel B – Blind/shutter: {{0}}Block1 Bit1.3 enableCW
48Channel B – Switching sequence: {{0}}Reset switching sequence1 Bit1.17 triggerCW
48Channel B – Pulse counter 2: {{0}}Request counter value1 Bit1.17 triggerCW
49Channel B – Switching sequence: {{0}}Next/previous step1 Bit1.7 stepCW
49Channel B – Pulse counter 2: {{0}}Limit value reached1 Bit1.2 booleanCRT
50Channel B – Switching sequence: {{0}}Block1 Bit1.3 enableCW
50Channel B – Pulse counter: {{0}}Block1 Bit1.3 enableCW
Parameters (309)
ParameterTypeDefault
DevicelistUSU
Signal typelistINTERNAL
Manual operationunsignedInt 0…10
Number of inputsunsignedInt 2…122
Enable templatesunsignedInt 0…11
CalcParamunsignedInt 0…2550
Logic 1-4unsignedInt 0…11
1#Device settings$CentralunsignedInt 0…2550
2#Logic$LogicunsignedInt 0…2550
3#TemplatesunsignedInt 0…2550
4#Channel A||Channel A+B$Channel AunsignedInt 0…2550
5#Channel B$Channel BunsignedInt 0…2550
UCC_ENDunsignedInt 0…65535404
ApplicationlistDevice
Parameter SizeunsignedInt 0…655358
Sending delay after KNX voltage recoveryunsignedInt 2…602
Telegram rate limitunsignedInt 0…10
Maximum number of sent telegramsunsignedInt 0…10020
In periodunsignedInt 0…591
Access to i-bus ToollistFull access
Enable Group Object "In operation"listNo
Sending cycletime600
Enable Time Group Objects for setting of device timelistNo
Request Date/Time via Group ObjectunsignedInt 0…10
Config lengthunsignedInt 0…655350
ApplicationlistLogic
Parameter SizeunsignedInt 0…6553512
Logic functionlistNone
Connection AlistDeactivated
Default setting "Connection A"listRead value
Connection BlistDeactivated
Default setting "Connection B"listRead value
Channel AlistApply value
Channel BlistApply value
Block logiclistDeactivated
State after ETS download or KNX voltage recoverylistLast state
Invert resultunsignedInt 0…10
Send "Status Result"listOn change
ApplicationlistSwitch template
Parameter SizeunsignedInt 0…6553528
DevicelistBES
DevicelistFTS
Descriptiontext
Templates activatedunsignedInt 0…11
Templates activatedunsignedInt 0…10
Parameter settingunsignedInt 0…10
Distinction between short and long operationunsignedInt 0…10
Reaction on short operationlistOn
Reaction on long operationlistOff
Reaction on opening the contactlistOff
Reaction on closing the contactlistOn
Reaction when touchedlistToggle
Reaction on releaselistNo reaction
Send input status after ETS download or KNX voltage recoveryunsignedInt 0…10
Extended settingsunsignedInt 0…10
Enable function "Switch 2"unsignedInt 0…10
Enable function Switch 2unsignedInt 0…10
FunctionCodelistDIOCONF_PUSH_BUTTON_SENSOR
Contact typelistNO contact
Long operation aftertime400
Long operation afterunsignedInt 0…65535400
Signal typelistAutomatic
Interference suppression filterunsignedInt 12…15030
Interference suppression filterunsignedInt 60…15060
Block inputlistDeactivated
Block operating arealistDeactivated
Config lengthunsignedInt 0…6553515
ConfigunsignedInt 0…42949672950
ApplicationlistSwitch (2-button) template
Parameter SizeunsignedInt 0…6553526
Reaction on operationlistOn
Reaction on operationlistOff
Reaction on operationlistToggle
FunctionCodelistDIOCONF_PUSH_BUTTON_2_BUTTON_SENSOR
ConfigunsignedInt 0…655350
ApplicationlistBlind/shutter template
Parameter SizeunsignedInt 0…6553539
Operating modelistBlind
Blind operationlistShort: step/stop, long: move
Shutter operationlistShort: stop, long: move
Stop movementlistOn release
Cycle for sending the step/stop telegramtime500
Cycle for sending the Step/Stop telegramunsignedInt 0…65535500
"Movement" direction change aftertime0
"Slat" direction change aftertime5000
ApplicationlistBlind/shutter (2-button) template
Parameter SizeunsignedInt 0…6553531
Direction of movementlistUp
Direction of movementlistDown
ApplicationlistSwitch/dim template
On short operationlistToggle
On long operationlistChange dimming direction, darker when On
Dimming methodlistStart-stop-dimming
Dimming processlistStart-stop-dimming
Change per steplist3 %
Telegram is repeated everytime600
Telegram is repeated everyunsignedInt 0…65535600
ApplicationlistSwitch/dim (2-button) template
Parameter SizeunsignedInt 0…6553532
On short operationlistOn
On long operationlistBrighter
On short operationlistOff
On long operationlistDarker
ApplicationlistScenes template
Distinction between short and long operationunsignedInt 0…11
Scene numberunsignedInt 1…641
On short operation: Scene numberunsignedInt 1…641
ScenelistSend
Reaction on long operationlistSave scene
On long operation: Scene numberunsignedInt 1…641
Long operation aftertime3000
Long operation afterunsignedInt 0…655353000
ApplicationlistSend value/multiple operation template
Parameter SizeunsignedInt 0…6553555
Send value onlist1-fold operation
Toggle valueunsignedInt 0…10
Maximum time between two operationstime500
Maximum time between two operationsunsignedInt 0…65535500
Send values on every operationunsignedInt 0…10
On change of contact: DPTlistSwitch [DPT 1.001]
OperationlistClose
OperationlistToggle
There is text in the "Default value" columnlistShort operation
There is text in the "Default value" columnlist1-fold operation
On short operation: DPTlistSwitch [DPT 1.001]
On 1-fold operation: DPTlistSwitch [DPT 1.001]
Value 1 of Group Object "Value 1: Switch"listOn
Value 1 of Group Object "Value 1: Switch"listToggle
Value of Group Object "Value 1: Percent"unsignedInt 0…1000
Value of Group Object "Value 1: Percent"unsignedInt 0…2550
Value of Group Object "Value 1: Forced operation"listForced operation, value 1
Value of Group Object "Value 1: Temperature"signedInt -100…25020
Value of Group Object "Value 1: Temperature"signedInt -32768…327672000
Value of Group Object "Value 1: Color"color#000000
Value of Group Object "Value 1: HVAC mode"listAutomatic
Value of Group Object "Value 1: 1 byte"unsignedInt 0…2550
Value of Group Object "Value 1: 1 byte signed"signedInt -128…1270
Value of Group Object "Value 1: 2 bytes"unsignedInt 0…655350
Value of Group Object "Value 1: 2 bytes signed"signedInt -32768…327670
Value of Group Object "Value 1: 4 bytes"unsignedInt 0…42949672950
Value of Group Object "Value 3: Percent"unsignedInt 0…1000
Value of Group Object "Value 3: Percent"unsignedInt 0…2550
Value of Group Object "Value 3: Forced operation"listNo forced operation
Value of Group Object "Value 3: Temperature"signedInt -100…25020
Value of Group Object "Value 3: Temperature"signedInt -32768…327672000
Value of Group Object "Value 3: Color"color#000000
Value of Group Object "Value 3: HVAC mode"listAutomatic
Value of Group Object "Value 3: 1 byte"unsignedInt 0…2550
Value of Group Object "Value 3: 1 byte signed"signedInt -128…1270
Value of Group Object "Value 3: 2 bytes"unsignedInt 0…655350
Value of Group Object "Value 3: 2 bytes signed"signedInt -32768…327670
Value of Group Object "Value 3: 4 bytes"unsignedInt 0…42949672950
There is text in the "Default value" columnlistLong operation
There is text in the "Default value" columnlist2-fold operation
OperationlistNo reaction
On long operation: DPTlistSwitch [DPT 1.001]
On 2-fold operation: DPTlistSwitch [DPT 1.001]
Value 2 of Group Object "Value 1: Switch"listOff
Value 2 of Group Object "Value 1: Switch"listToggle
Value of Group Object "Value 2: Percent"unsignedInt 0…1000
Value of Group Object "Value 2: Percent"unsignedInt 0…2550
Value of Group Object "Value 2: Forced operation"listForced operation, value 0
Value of Group Object "Value 2: Temperature"signedInt -100…25020
Value of Group Object "Value 2: Temperature"signedInt -32768…327672000
Value of Group Object "Value 2: Color"color#000000
Value of Group Object "Value 2: HVAC mode"listAutomatic
Value of Group Object "Value 2: 1 byte"unsignedInt 0…2550
Value of Group Object "Value 2: 1 byte signed"signedInt -128…1270
Value of Group Object "Value 2: 2 bytes"unsignedInt 0…655350
Value of Group Object "Value 2: 2 bytes signed"signedInt -32768…327670
Value of Group Object "Value 2: 4 bytes"unsignedInt 0…42949672950
Value of Group Object "Value 4: Percent"unsignedInt 0…1000
Value of Group Object "Value 4: Percent"unsignedInt 0…2550
Value of Group Object "Value 4: Forced operation"listNo forced operation
Value of Group Object "Value 4: Temperature"signedInt -100…25020
Value of Group Object "Value 4: Temperature"signedInt -32768…327672000
Value of Group Object "Value 4: Color"color#000000
Value of Group Object "Value 4: HVAC mode"listAutomatic
Value of Group Object "Value 4: 1 byte"unsignedInt 0…2550
Value of Group Object "Value 4: 1 byte signed"signedInt -128…1270
Value of Group Object "Value 4: 2 bytes"unsignedInt 0…655350
Value of Group Object "Value 4: 2 bytes signed"signedInt -32768…327670
Value of Group Object "Value 4: 4 bytes"unsignedInt 0…42949672950
There is text in the "Default value" columnlist3-fold operation
On 3-fold operation: DPTlistDeactivated
Value of Group Object "Value 3: Switch"listOff
Long operationlistLong operation
On long operation: DPTlistDeactivated
Value of Group Object "Value 4: Switch"listOn
Activate minimum signal durationunsignedInt 0…10
On opening the contacttime1000
On closing the contacttime1000
ApplicationlistSwitching sequence template
Parameter SizeunsignedInt 0…65535130
App_2ButtonunsignedInt 0…10
FunctionlistSwitch
FunctionlistDeactivated
enable 0unsignedInt 0…11
EnableunsignedInt 0…11
GO 1listOff
GO 1unsignedInt 0…1000
GO 1unsignedInt 0…2550
GO 1unsignedInt 0…2551
GO 1unsignedInt 1…641
GO 1color#000000
GO 1listAutomatic
GO 2listOff
GO 2unsignedInt 0…1000
GO 2unsignedInt 0…2550
GO 2unsignedInt 0…2551
GO 2unsignedInt 1…641
GO 2color#000000
GO 2listAutomatic
GO 3listOff
GO 3unsignedInt 0…1000
GO 3unsignedInt 0…2550
GO 3unsignedInt 0…2551
GO 3unsignedInt 1…641
GO 3color#000000
GO 3listAutomatic
GO 4listOff
GO 4unsignedInt 0…1000
GO 4unsignedInt 0…2550
GO 4unsignedInt 0…2551
GO 4unsignedInt 1…641
GO 4color#000000
GO 4listAutomatic
GO 5listOff
GO 5unsignedInt 0…1000
GO 5unsignedInt 0…2550
GO 5unsignedInt 0…2551
GO 5unsignedInt 1…641
GO 5color#000000
GO 5listAutomatic
EnableunsignedInt 0…10
Reaction on long operationlistCorresponds to a short operation
Reaction after last steplistStep 1
Behavior after last steplistNo reaction
Reaction on short operationlistNext step
Reaction on short operationlistPrevious step
Send values after evaluation periodunsignedInt 0…10
Evaluation periodtime2000
Evaluation periodunsignedInt 0…655352000
Enable Group Object "Reset switching sequence"unsignedInt 0…10
App_2ButtonunsignedInt 0…11
ApplicationlistFault indicator/logic Input template
Send value of Group Object "Status Fault"listOn change
Sending cycletime30
On Group Object valuelist0 or 1
Send "Status Fault" after ETS download or KNX voltage recoveryunsignedInt 0…10
ApplicationlistPulse counter template
Parameter SizeunsignedInt 0…6553564
Counter typelist4 bytes unsigned [DPT 12.001]
Generate input pulselistOn closing
Enable Counter 1unsignedInt 0…11
Enable pulse counter 2unsignedInt 0…10
FunctionCodelistDIOCONF_COUNTER
Minimum signal durationunsignedInt 20…10030
Signal typelistDC
Send value of Group Object "Counter value 1"listOn change
Sending cycletime86400
Value is sent from a change ofunsignedInt 1…10000100
Counter-specific settingsunsignedInt 0…10
Start valuesignedInt -128…1270
Initial valuesignedInt -128…1270
Start valueunsignedInt 0…2550
Initial valueunsignedInt 0…2550
Start valuesignedInt -32768…327670
Initial valuesignedInt -32768…327670
Start valueunsignedInt 0…655350
Initial valueunsignedInt 0…655350
Start valuesignedInt -2147483648…21474836470
Initial valuesignedInt -2147483648…21474836470
Start valueunsignedInt 0…42949672950
Initial valueunsignedInt 0…42949672950
Number of input pulses for one counter stepunsignedInt 1…100001
Number of input pulses per counting pulseunsignedInt 1…100001
Change of counter per counter stepsignedInt -10000…100001
Counter reading change per counting pulsesignedInt -10000…100001
Evaluate limit valueunsignedInt 0…10
Limit valuesignedInt -128…127100
Limit valueunsignedInt 0…255100
Limit valuesignedInt -32768…32767100
Limit valueunsignedInt 0…65535100
Limit valuesignedInt -2147483648…2147483647100
Limit valueunsignedInt 0…4294967295100
Reaction on reaching limit valuelistReset to initial value
Send value of Group Object "Counter value 2"listOn change
ApplicationlistLED control template
Parameter SizeunsignedInt 0…6553527
LED functionlistOn/off
Reaction on telegram valuelist1: on, 0: off
Flashing on telegram valuelist1
Time for Ontime1000
Time for Offtime1000
LED control time limitunsignedInt 0…10
Durationtime60
Send value of Group Object "Status"unsignedInt 0…10
State after ETS download or KNX voltage recoverylistLED off
FunctionCodelistDIOCONF_LED_OUTPUT
ConfigunsignedInt 0…2550
ApplicationlistSwitch
CHANNEL_MP_CTunsignedInt 0…42949672950
Parameter settingunsignedInt 0…11
BinaryInput_1_TextVirtualtextChannel A
BinaryInput_1_StextChannel A
BinaryInput_1_DtextChannel A+B
ConfigunsignedInt 0…167772150
Channel Atext

Application program: Universal Interface, 2f/2.0 2.0

Application number$B123
Version2.0
Mask versionMV-07B0 (System B)
KNX Data SecureNo
Minimum ETS version5.0
Parameters0
Group objects0
Group objects (0)
NoNameFunctionSizeDPTFlags
Parameters (0)
ParameterTypeDefault

Version history

ApplicationApp noFingerprintFirst seenSizeFile
Universal Interface, 2f/1.0 1.0 latest$B12325622026-11-25584 KBDownload

About this file

This is the official ETS product database for the ABB AG - STOTZ-KONTAKT US/U2.3 Universal Interface, 2-fold, FM (2CDG 110 308 R0011), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.

More from ABB AG - STOTZ-KONTAKT