ABB AG - STOTZ-KONTAKT 2CDG 110 277 R0011 BE/S10.20.3.2 Binary Input, 10-fold, Contact Scanning, MDRC

BE/S10.20.3.2 Binary Input, 10-fold, Contact Scanning, MDRC 2CDG 110 277 R0011

ABB AG - STOTZ-KONTAKT · Order number 2CDG 110 277 R0011 · Standard Inputs › Binary Inputs Contact Scanning

Download .knxprod Binary Input 10f 20/1.0 1.0 · 1.6 MB

Product

ManufacturerABB AG - STOTZ-KONTAKT
Product nameBE/S10.20.3.2 Binary Input, 10-fold, Contact Scanning, MDRC
Order number2CDG 110 277 R0011
HardwareBE/S10.20.3.2 Binary Input, 10-fold, Contact scanning, MDRC
MediumTwisted Pair
Bus current (mA)10
Rail mountedYes
Width (mm)70
RegistrationRegistered · 2024-10-02
Languagesen-US, de-DE, es-ES, fr-FR, it-IT, nl-NL, pl-PL, ru-RU
Catalog entryM-0002_H-2CDG.20110.20277.20R0011-1_HP-A0E7-10-6B76-A0E7-20-225C_CI-2CDG.20110.20277.20R0011-1
Fingerprint6B76
SHA-256556643b8b6b5c1e0f9379580c7c7fae1d87c8f6c06c4b028cff0abefe431b2a0
First seen2026-11-25
Markets59 markets

Application program: Binary Input 10f 20/1.0 1.0

Application number$A0E7
Version1.0
Mask versionMV-07B0 (System B)
KNX Data SecureYes
Minimum ETS version5.0
Parameters11062
Group objects1468
Group objects (1468)
NoNameFunctionSizeDPTFlags
1Central – General: In operation1 Bit1.2 booleanCRT
2Central – Date/time: Set time3 Bytes10.1 time of dayCW
3Central – Date/time: Set date3 Bytes11.1 dateCW
4Central – Date/time: Set date/time8 Bytes19.1 date timeCW
5Central – Date/time: Request date/time1 Bit1.17 triggerCT
6Central – Manual operation: Status Manual operation1 Bit1.11 stateCRT
7Central – Manual operation: Enable/block manual operation1 Bit1.3 enableCW
8Central – Manual operation: Deactivate Manual operation1 Bit1.17 triggerCW
9Logic – Connection 1: Connection A1 Bit1.2 booleanCWTU
10Logic – Connection 1: Connection B1 Bit1.2 booleanCWTU
11Logic – Result 1: Status Result1 Bit1.2 booleanCRT
12Logic – Block 1: Block logic1 Bit1.3 enableCW
13Logic – Request 1: Request status values1 Bit1.17 triggerCW
14Logic – Connection 2: Connection A1 Bit1.2 booleanCWTU
15Logic – Connection 2: Connection B1 Bit1.2 booleanCWTU
16Logic – Result 2: Status Result1 Bit1.2 booleanCRT
17Logic – Block 2: Block logic1 Bit1.3 enableCW
18Logic – Request 2: Request status values1 Bit1.17 triggerCW
19Logic – Connection 3: Connection A1 Bit1.2 booleanCWTU
20Logic – Connection 3: Connection B1 Bit1.2 booleanCWTU
21Logic – Result 3: Status Result1 Bit1.2 booleanCRT
22Logic – Block 3: Block logic1 Bit1.3 enableCW
23Logic – Request 3: Request status values1 Bit1.17 triggerCW
24Logic – Connection 4: Connection A1 Bit1.2 booleanCWTU
25Logic – Connection 4: Connection B1 Bit1.2 booleanCWTU
26Logic – Result 4: Status Result1 Bit1.2 booleanCRT
27Logic – Block 4: Block logic1 Bit1.3 enableCW
28Logic – Request 4: Request status values1 Bit1.17 triggerCW
29Logic – Connection 5: Connection A1 Bit1.2 booleanCWTU
30Logic – Connection 5: Connection B1 Bit1.2 booleanCWTU
31Logic – Result 5: Status Result1 Bit1.2 booleanCRT
32Logic – Block 5: Block logic1 Bit1.3 enableCW
33Logic – Request 5: Request status values1 Bit1.17 triggerCW
34Logic – Connection 6: Connection A1 Bit1.2 booleanCWTU
35Logic – Connection 6: Connection B1 Bit1.2 booleanCWTU
36Logic – Result 6: Status Result1 Bit1.2 booleanCRT
37Logic – Block 6: Block logic1 Bit1.3 enableCW
38Logic – Request 6: Request status values1 Bit1.17 triggerCW
39Logic – Connection 7: Connection A1 Bit1.2 booleanCWTU
40Logic – Connection 7: Connection B1 Bit1.2 booleanCWTU
41Logic – Result 7: Status Result1 Bit1.2 booleanCRT
42Logic – Block 7: Block logic1 Bit1.3 enableCW
43Logic – Request 7: Request status values1 Bit1.17 triggerCW
44Logic – Connection 8: Connection A1 Bit1.2 booleanCWTU
45Logic – Connection 8: Connection B1 Bit1.2 booleanCWTU
46Logic – Result 8: Status Result1 Bit1.2 booleanCRT
47Logic – Block 8: Block logic1 Bit1.3 enableCW
48Logic – Request 8: Request status values1 Bit1.17 triggerCW
49Logic – Connection 9: Connection A1 Bit1.2 booleanCWTU
50Logic – Connection 9: Connection B1 Bit1.2 booleanCWTU
51Logic – Result 9: Status Result1 Bit1.2 booleanCRT
52Logic – Block 9: Block logic1 Bit1.3 enableCW
53Logic – Request 9: Request status values1 Bit1.17 triggerCW
54Logic – Connection 10: Connection A1 Bit1.2 booleanCWTU
55Logic – Connection 10: Connection B1 Bit1.2 booleanCWTU
56Logic – Result 10: Status Result1 Bit1.2 booleanCRT
57Logic – Block 10: Block logic1 Bit1.3 enableCW
58Logic – Request 10: Request status values1 Bit1.17 triggerCW
59Logic – Connection 11: Connection A1 Bit1.2 booleanCWTU
60Logic – Connection 11: Connection B1 Bit1.2 booleanCWTU
61Logic – Result 11: Status Result1 Bit1.2 booleanCRT
62Logic – Block 11: Block logic1 Bit1.3 enableCW
63Logic – Request 11: Request status values1 Bit1.17 triggerCW
64Logic – Connection 12: Connection A1 Bit1.2 booleanCWTU
65Logic – Connection 12: Connection B1 Bit1.2 booleanCWTU
66Logic – Result 12: Status Result1 Bit1.2 booleanCRT
67Logic – Block 12: Block logic1 Bit1.3 enableCW
68Logic – Request 12: Request status values1 Bit1.17 triggerCW
69Input a – Switch: {{0}}Switch1 Bit1.1 switchCWTU
69Input a+b – Switch: {{0}}Switch1 Bit1.1 switchCWTU
69Input a – Blind/shutter: {{0}}Up/down1 Bit1.8 up/downCWTU
69Input a+b – Blind/shutter: {{0}}Up/down1 Bit1.8 up/downCWTU
69Input a – Switch/dim: {{0}}Dimming4 Bit3.7 dimming controlCT
69Input a+b – Switch/dim: {{0}}Dimming4 Bit3.7 dimming controlCT
69Input a – Scene: {{0}}Scene 1…641 Byte18.1 scene controlCT
69Input a – Send value: {{0}}Value 1: Switch1 Bit1.1 switchCWTU
69Input a – Send value: {{0}}Value 1: Percent1 Byte5.1 percentage (0..100%)CWTU
69Input a – Send value: {{0}}Value 1: Forced operation2 Bit2.1 switch controlCRWT
69Input a – Send value: {{0}}Value 1: Temperature2 Bytes9.1 temperature (°C)CWTU
69Input a – Send value: {{0}}Value 1: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
69Input a – Send value: {{0}}Value 1: HVAC mode1 Byte20.102 HVAC modeCWTU
69Input a – Send value: {{0}}Value 1: 1 byte1 Byte5.10 counter pulses (0..255)CWTU
69Input a – Send value: {{0}}Value 1: 1 byte signed1 Byte6.10 counter pulses (-128..127)CWTU
69Input a – Send value: {{0}}Value 1: 2 bytes2 Bytes7.1 pulsesCWTU
69Input a – Send value: {{0}}Value 1: 2 bytes signed2 Bytes8.1 pulses differenceCWTU
69Input a – Send value: {{0}}Value 1: 4 bytes4 Bytes12.1 counter pulses (unsigned)CWTU
69Input a – Fault indicator/logic input: {{0}}Status Fault1 Bit1.11 stateCRWT
69Input a – Switching sequence: {{0}}Value 1: Switch1 Bit1.1 switchCWTU
69Input a – Switching sequence: {{0}}Value 1: Percent1 Byte5.1 percentage (0..100%)CWTU
69Input a – Switching sequence: {{0}}Value 1: Byte1 Byte5.10 counter pulses (0..255)CWTU
69Input a – Switching sequence: {{0}}Value 1: Scene1 Byte18.1 scene controlCWTU
69Input a – Switching sequence: {{0}}Value 1: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
69Input a – Switching sequence: {{0}}Value 1: HVAC mode1 Byte20.102 HVAC modeCWTU
69Input a+b – Switching sequence: {{0}}Value 1: Switch1 Bit1.1 switchCWTU
69Input a+b – Switching sequence: {{0}}Value 1: Percent1 Byte5.1 percentage (0..100%)CWTU
69Input a+b – Switching sequence: {{0}}Value 1: Byte1 Byte5.10 counter pulses (0..255)CWTU
69Input a+b – Switching sequence: {{0}}Value 1: Scene1 Byte18.1 scene controlCWTU
69Input a+b – Switching sequence: {{0}}Value 1: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
69Input a+b – Switching sequence: {{0}}Value 1: HVAC mode1 Byte20.102 HVAC modeCWTU
69Input a – Pulse counter 1: {{0}}Counter value1 Byte6.10 counter pulses (-128..127)CRT
69Input a – Pulse counter 1: {{0}}Counter value1 Byte5.10 counter pulses (0..255)CRT
69Input a – Pulse counter 1: {{0}}Counter value2 Bytes8.1 pulses differenceCRT
69Input a – Pulse counter 1: {{0}}Counter value2 Bytes7.1 pulsesCRT
69Input a – Pulse counter 1: {{0}}Counter value4 Bytes13.1 counter pulses (signed)CRT
69Input a – Pulse counter 1: {{0}}Counter value4 Bytes12.1 counter pulses (unsigned)CRT
70Input a – Switch: {{0}}Block1 Bit1.3 enableCW
70Input a+b – Switch: {{0}}Block1 Bit1.3 enableCW
70Input a – Blind/shutter: {{0}}Step/stop1 Bit1.7 stepCWTU
70Input a – Blind/shutter: {{0}}Stop1 Bit1.17 triggerCWTU
70Input a+b – Blind/shutter: {{0}}Step/stop1 Bit1.7 stepCWTU
70Input a+b – Blind/shutter: {{0}}Stop1 Bit1.17 triggerCWTU
70Input a – Switch/dim: {{0}}Switch1 Bit1.1 switchCWTU
70Input a+b – Switch/dim: {{0}}Switch1 Bit1.1 switchCWTU
70Input a – Scene: {{0}}Block1 Bit1.3 enableCW
70Input a – Send value: {{0}}Value 2: Switch1 Bit1.1 switchCWTU
70Input a – Send value: {{0}}Value 2: Percent1 Byte5.1 percentage (0..100%)CWTU
70Input a – Send value: {{0}}Value 2: Forced operation2 Bit2.1 switch controlCRWT
70Input a – Send value: {{0}}Value 2: Temperature2 Bytes9.1 temperature (°C)CWTU
70Input a – Send value: {{0}}Value 2: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
70Input a – Send value: {{0}}Value 2: HVAC mode1 Byte20.102 HVAC modeCWTU
70Input a – Send value: {{0}}Value 2: 1 byte1 Byte5.10 counter pulses (0..255)CWTU
70Input a – Send value: {{0}}Value 2: 1 byte signed1 Byte6.10 counter pulses (-128..127)CWTU
70Input a – Send value: {{0}}Value 2: 2 bytes2 Bytes7.1 pulsesCWTU
70Input a – Send value: {{0}}Value 2: 2 bytes signed2 Bytes8.1 pulses differenceCWTU
70Input a – Send value: {{0}}Value 2: 4 bytes4 Bytes12.1 counter pulses (unsigned)CWTU
70Input a – Fault indicator/logic input: {{0}}Block1 Bit1.3 enableCW
70Input a – Switching sequence: {{0}}Value 2: Switch1 Bit1.1 switchCWTU
70Input a – Switching sequence: {{0}}Value 2: Percent1 Byte5.1 percentage (0..100%)CWTU
70Input a – Switching sequence: {{0}}Value 2: Byte1 Byte5.10 counter pulses (0..255)CWTU
70Input a – Switching sequence: {{0}}Value 2: Scene1 Byte18.1 scene controlCWTU
70Input a – Switching sequence: {{0}}Value 2: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
70Input a – Switching sequence: {{0}}Value 2: HVAC mode1 Byte20.102 HVAC modeCWTU
70Input a+b – Switching sequence: {{0}}Value 2: Switch1 Bit1.1 switchCWTU
70Input a+b – Switching sequence: {{0}}Value 2: Percent1 Byte5.1 percentage (0..100%)CWTU
70Input a+b – Switching sequence: {{0}}Value 2: Byte1 Byte5.10 counter pulses (0..255)CWTU
70Input a+b – Switching sequence: {{0}}Value 2: Scene1 Byte18.1 scene controlCWTU
70Input a+b – Switching sequence: {{0}}Value 2: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
70Input a+b – Switching sequence: {{0}}Value 2: HVAC mode1 Byte20.102 HVAC modeCWTU
70Input a – Pulse counter 1: {{0}}Reset counter value1 Bit1.15 resetCW
71Input a – Switch: {{0}}Switch 21 Bit1.1 switchCWTU
71Input a+b – Blind/shutter: {{0}}Status Upper end position1 Bit1.2 booleanCWU
71Input a+b – Switch/dim: {{0}}Block1 Bit1.3 enableCW
71Input a – Send value: {{0}}Value 3: Switch1 Bit1.1 switchCWTU
71Input a – Send value: {{0}}Value 3: Percent1 Byte5.1 percentage (0..100%)CWTU
71Input a – Send value: {{0}}Value 3: Forced operation2 Bit2.1 switch controlCWTU
71Input a – Send value: {{0}}Value 3: Temperature2 Bytes9.1 temperature (°C)CWTU
71Input a – Send value: {{0}}Value 3: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
71Input a – Send value: {{0}}Value 3: HVAC mode1 Byte20.102 HVAC modeCWTU
71Input a – Send value: {{0}}Value 3: 1 byte1 Byte5.10 counter pulses (0..255)CWTU
71Input a – Send value: {{0}}Value 3: 1 byte signed1 Byte6.10 counter pulses (-128..127)CWTU
71Input a – Send value: {{0}}Value 3: 2 bytes2 Bytes7.1 pulsesCWTU
71Input a – Send value: {{0}}Value 3: 2 bytes signed2 Bytes8.1 pulses differenceCWTU
71Input a – Send value: {{0}}Value 3: 4 bytes4 Bytes12.1 counter pulses (unsigned)CWTU
71Input a – Fault indicator/logic input: {{0}}Request status Fault1 Bit1.17 triggerCW
71Input a – Switching sequence: {{0}}Value 3: Switch1 Bit1.1 switchCWTU
71Input a – Switching sequence: {{0}}Value 3: Percent1 Byte5.1 percentage (0..100%)CWTU
71Input a – Switching sequence: {{0}}Value 3: Byte1 Byte5.10 counter pulses (0..255)CWTU
71Input a – Switching sequence: {{0}}Value 3: Scene1 Byte18.1 scene controlCWTU
71Input a – Switching sequence: {{0}}Value 3: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
71Input a – Switching sequence: {{0}}Value 3: HVAC mode1 Byte20.102 HVAC modeCWTU
71Input a+b – Switching sequence: {{0}}Value 3: Switch1 Bit1.1 switchCWTU
71Input a+b – Switching sequence: {{0}}Value 3: Percent1 Byte5.1 percentage (0..100%)CWTU
71Input a+b – Switching sequence: {{0}}Value 3: Byte1 Byte5.10 counter pulses (0..255)CWTU
71Input a+b – Switching sequence: {{0}}Value 3: Scene1 Byte18.1 scene controlCWTU
71Input a+b – Switching sequence: {{0}}Value 3: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
71Input a+b – Switching sequence: {{0}}Value 3: HVAC mode1 Byte20.102 HVAC modeCWTU
71Input a – Pulse counter 1: {{0}}Request counter value1 Bit1.17 triggerCW
72Input a – Switch: {{0}}Block 21 Bit1.3 enableCW
72Input a – Blind/shutter: {{0}}Status Upper end position1 Bit1.2 booleanCWU
72Input a+b – Blind/shutter: {{0}}Status Lower end position1 Bit1.2 booleanCWU
72Input a – Switch/dim: {{0}}Block1 Bit1.3 enableCW
72Input a – Send value: {{0}}Value 4: Switch1 Bit1.1 switchCWTU
72Input a – Send value: {{0}}Value 4: Percent1 Byte5.1 percentage (0..100%)CWTU
72Input a – Send value: {{0}}Value 4: Forced operation2 Bit2.1 switch controlCWTU
72Input a – Send value: {{0}}Value 4: Temperature2 Bytes9.1 temperature (°C)CWTU
72Input a – Send value: {{0}}Value 4: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
72Input a – Send value: {{0}}Value 4: HVAC mode1 Byte20.102 HVAC modeCWTU
72Input a – Send value: {{0}}Value 4: 1 byte1 Byte5.10 counter pulses (0..255)CWTU
72Input a – Send value: {{0}}Value 4: 1 byte signed1 Byte6.10 counter pulses (-128..127)CWTU
72Input a – Send value: {{0}}Value 4: 2 bytes2 Bytes7.1 pulsesCWTU
72Input a – Send value: {{0}}Value 4: 2 bytes signed2 Bytes8.1 pulses differenceCWTU
72Input a – Send value: {{0}}Value 4: 4 bytes4 Bytes12.1 counter pulses (unsigned)CWTU
72Input a – Switching sequence: {{0}}Value 4: Switch1 Bit1.1 switchCWTU
72Input a – Switching sequence: {{0}}Value 4: Percent1 Byte5.1 percentage (0..100%)CWTU
72Input a – Switching sequence: {{0}}Value 4: Byte1 Byte5.10 counter pulses (0..255)CWTU
72Input a – Switching sequence: {{0}}Value 4: Scene1 Byte18.1 scene controlCWTU
72Input a – Switching sequence: {{0}}Value 4: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
72Input a – Switching sequence: {{0}}Value 4: HVAC mode1 Byte20.102 HVAC modeCWTU
72Input a+b – Switching sequence: {{0}}Value 4: Switch1 Bit1.1 switchCWTU
72Input a+b – Switching sequence: {{0}}Value 4: Percent1 Byte5.1 percentage (0..100%)CWTU
72Input a+b – Switching sequence: {{0}}Value 4: Byte1 Byte5.10 counter pulses (0..255)CWTU
72Input a+b – Switching sequence: {{0}}Value 4: Scene1 Byte18.1 scene controlCWTU
72Input a+b – Switching sequence: {{0}}Value 4: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
72Input a+b – Switching sequence: {{0}}Value 4: HVAC mode1 Byte20.102 HVAC modeCWTU
72Input a – Pulse counter 1: {{0}}Limit value reached1 Bit1.2 booleanCRT
73Input a – Blind/shutter: {{0}}Status Lower end position1 Bit1.2 booleanCWU
73Input a+b – Blind/shutter: {{0}}Status Move1 Bit1.2 booleanCWU
73Input a – Send value: {{0}}Block1 Bit1.3 enableCWTU
73Input a – Switching sequence: {{0}}Value 5: Switch1 Bit1.1 switchCWTU
73Input a – Switching sequence: {{0}}Value 5: Percent1 Byte5.1 percentage (0..100%)CWTU
73Input a – Switching sequence: {{0}}Value 5: Byte1 Byte5.10 counter pulses (0..255)CWTU
73Input a – Switching sequence: {{0}}Value 5: Scene1 Byte18.1 scene controlCWTU
73Input a – Switching sequence: {{0}}Value 5: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
73Input a – Switching sequence: {{0}}Value 5: HVAC mode1 Byte20.102 HVAC modeCWTU
73Input a+b – Switching sequence: {{0}}Value 5: Switch1 Bit1.1 switchCWTU
73Input a+b – Switching sequence: {{0}}Value 5: Percent1 Byte5.1 percentage (0..100%)CWTU
73Input a+b – Switching sequence: {{0}}Value 5: Byte1 Byte5.10 counter pulses (0..255)CWTU
73Input a+b – Switching sequence: {{0}}Value 5: Scene1 Byte18.1 scene controlCWTU
73Input a+b – Switching sequence: {{0}}Value 5: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
73Input a+b – Switching sequence: {{0}}Value 5: HVAC mode1 Byte20.102 HVAC modeCWTU
73Input a – Pulse counter 2: {{0}}Counter value1 Byte6.10 counter pulses (-128..127)CRT
73Input a – Pulse counter 2: {{0}}Counter value1 Byte5.10 counter pulses (0..255)CRT
73Input a – Pulse counter 2: {{0}}Counter value2 Bytes8.1 pulses differenceCRT
73Input a – Pulse counter 2: {{0}}Counter value2 Bytes7.1 pulsesCRT
73Input a – Pulse counter 2: {{0}}Counter value4 Bytes13.1 counter pulses (signed)CRT
73Input a – Pulse counter 2: {{0}}Counter value4 Bytes12.1 counter pulses (unsigned)CRT
74Input a – Blind/shutter: {{0}}Status Move1 Bit1.2 booleanCWU
74Input a+b – Blind/shutter: {{0}}Block1 Bit1.3 enableCW
74Input a – Switching sequence: {{0}}Number of operations1 Byte5.10 counter pulses (0..255)CWTU
74Input a+b – Switching sequence: {{0}}Number of operations1 Byte5.10 counter pulses (0..255)CWTU
74Input a – Pulse counter 2: {{0}}Reset counter value1 Bit1.15 resetCW
75Input a – Blind/shutter: {{0}}Block1 Bit1.3 enableCW
75Input a – Switching sequence: {{0}}Reset switching sequence1 Bit1.17 triggerCW
75Input a+b – Switching sequence: {{0}}Reset switching sequence1 Bit1.17 triggerCW
75Input a – Pulse counter 2: {{0}}Request counter value1 Bit1.17 triggerCW
76Input a – Switching sequence: {{0}}Next/previous step1 Bit1.7 stepCW
76Input a+b – Switching sequence: {{0}}Next/previous step1 Bit1.7 stepCW
76Input a – Pulse counter 2: {{0}}Limit value reached1 Bit1.2 booleanCRT
77Input a – Switching sequence: {{0}}Block1 Bit1.3 enableCW
77Input a+b – Switching sequence: {{0}}Block1 Bit1.3 enableCW
77Input a – Pulse counter: {{0}}Block1 Bit1.3 enableCW
78Input b – Switch: {{0}}Switch1 Bit1.1 switchCWTU
78Input b – Blind/shutter: {{0}}Up/down1 Bit1.8 up/downCWTU
78Input b – Switch/dim: {{0}}Dimming4 Bit3.7 dimming controlCT
78Input b – Scene: {{0}}Scene 1…641 Byte18.1 scene controlCT
78Input b – Send value: {{0}}Value 1: Switch1 Bit1.1 switchCWTU
78Input b – Send value: {{0}}Value 1: Percent1 Byte5.1 percentage (0..100%)CWTU
78Input b – Send value: {{0}}Value 1: Forced operation2 Bit2.1 switch controlCRWT
78Input b – Send value: {{0}}Value 1: Temperature2 Bytes9.1 temperature (°C)CWTU
78Input b – Send value: {{0}}Value 1: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
78Input b – Send value: {{0}}Value 1: HVAC mode1 Byte20.102 HVAC modeCWTU
78Input b – Send value: {{0}}Value 1: 1 byte1 Byte5.10 counter pulses (0..255)CWTU
78Input b – Send value: {{0}}Value 1: 1 byte signed1 Byte6.10 counter pulses (-128..127)CWTU
78Input b – Send value: {{0}}Value 1: 2 bytes2 Bytes7.1 pulsesCWTU
78Input b – Send value: {{0}}Value 1: 2 bytes signed2 Bytes8.1 pulses differenceCWTU
78Input b – Send value: {{0}}Value 1: 4 bytes4 Bytes12.1 counter pulses (unsigned)CWTU
78Input b – Fault indicator/logic input: {{0}}Status Fault1 Bit1.11 stateCRWT
78Input b – Switching sequence: {{0}}Value 1: Switch1 Bit1.1 switchCWTU
78Input b – Switching sequence: {{0}}Value 1: Percent1 Byte5.1 percentage (0..100%)CWTU
78Input b – Switching sequence: {{0}}Value 1: Byte1 Byte5.10 counter pulses (0..255)CWTU
78Input b – Switching sequence: {{0}}Value 1: Scene1 Byte18.1 scene controlCWTU
78Input b – Switching sequence: {{0}}Value 1: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
78Input b – Switching sequence: {{0}}Value 1: HVAC mode1 Byte20.102 HVAC modeCWTU
78Input b – Pulse counter 1: {{0}}Counter value1 Byte6.10 counter pulses (-128..127)CRT
78Input b – Pulse counter 1: {{0}}Counter value1 Byte5.10 counter pulses (0..255)CRT
78Input b – Pulse counter 1: {{0}}Counter value2 Bytes8.1 pulses differenceCRT
78Input b – Pulse counter 1: {{0}}Counter value2 Bytes7.1 pulsesCRT
78Input b – Pulse counter 1: {{0}}Counter value4 Bytes13.1 counter pulses (signed)CRT
78Input b – Pulse counter 1: {{0}}Counter value4 Bytes12.1 counter pulses (unsigned)CRT
79Input b – Switch: {{0}}Block1 Bit1.3 enableCW
79Input b – Blind/shutter: {{0}}Step/stop1 Bit1.7 stepCWTU
79Input b – Blind/shutter: {{0}}Stop1 Bit1.17 triggerCWTU
79Input b – Switch/dim: {{0}}Switch1 Bit1.1 switchCWTU
79Input b – Scene: {{0}}Block1 Bit1.3 enableCW
79Input b – Send value: {{0}}Value 2: Switch1 Bit1.1 switchCWTU
79Input b – Send value: {{0}}Value 2: Percent1 Byte5.1 percentage (0..100%)CWTU
79Input b – Send value: {{0}}Value 2: Forced operation2 Bit2.1 switch controlCRWT
79Input b – Send value: {{0}}Value 2: Temperature2 Bytes9.1 temperature (°C)CWTU
79Input b – Send value: {{0}}Value 2: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
79Input b – Send value: {{0}}Value 2: HVAC mode1 Byte20.102 HVAC modeCWTU
79Input b – Send value: {{0}}Value 2: 1 byte1 Byte5.10 counter pulses (0..255)CWTU
79Input b – Send value: {{0}}Value 2: 1 byte signed1 Byte6.10 counter pulses (-128..127)CWTU
79Input b – Send value: {{0}}Value 2: 2 bytes2 Bytes7.1 pulsesCWTU
79Input b – Send value: {{0}}Value 2: 2 bytes signed2 Bytes8.1 pulses differenceCWTU
79Input b – Send value: {{0}}Value 2: 4 bytes4 Bytes12.1 counter pulses (unsigned)CWTU
79Input b – Fault indicator/logic input: {{0}}Block1 Bit1.3 enableCW
79Input b – Switching sequence: {{0}}Value 2: Switch1 Bit1.1 switchCWTU
79Input b – Switching sequence: {{0}}Value 2: Percent1 Byte5.1 percentage (0..100%)CWTU
79Input b – Switching sequence: {{0}}Value 2: Byte1 Byte5.10 counter pulses (0..255)CWTU
79Input b – Switching sequence: {{0}}Value 2: Scene1 Byte18.1 scene controlCWTU
79Input b – Switching sequence: {{0}}Value 2: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
79Input b – Switching sequence: {{0}}Value 2: HVAC mode1 Byte20.102 HVAC modeCWTU
79Input b – Pulse counter 1: {{0}}Reset counter value1 Bit1.15 resetCW
80Input b – Switch: {{0}}Switch 21 Bit1.1 switchCWTU
80Input b – Send value: {{0}}Value 3: Switch1 Bit1.1 switchCWTU
80Input b – Send value: {{0}}Value 3: Percent1 Byte5.1 percentage (0..100%)CWTU
80Input b – Send value: {{0}}Value 3: Forced operation2 Bit2.1 switch controlCWTU
80Input b – Send value: {{0}}Value 3: Temperature2 Bytes9.1 temperature (°C)CWTU
80Input b – Send value: {{0}}Value 3: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
80Input b – Send value: {{0}}Value 3: HVAC mode1 Byte20.102 HVAC modeCWTU
80Input b – Send value: {{0}}Value 3: 1 byte1 Byte5.10 counter pulses (0..255)CWTU
80Input b – Send value: {{0}}Value 3: 1 byte signed1 Byte6.10 counter pulses (-128..127)CWTU
80Input b – Send value: {{0}}Value 3: 2 bytes2 Bytes7.1 pulsesCWTU
80Input b – Send value: {{0}}Value 3: 2 bytes signed2 Bytes8.1 pulses differenceCWTU
80Input b – Send value: {{0}}Value 3: 4 bytes4 Bytes12.1 counter pulses (unsigned)CWTU
80Input b – Fault indicator/logic input: {{0}}Request status Fault1 Bit1.17 triggerCW
80Input b – Switching sequence: {{0}}Value 3: Switch1 Bit1.1 switchCWTU
80Input b – Switching sequence: {{0}}Value 3: Percent1 Byte5.1 percentage (0..100%)CWTU
80Input b – Switching sequence: {{0}}Value 3: Byte1 Byte5.10 counter pulses (0..255)CWTU
80Input b – Switching sequence: {{0}}Value 3: Scene1 Byte18.1 scene controlCWTU
80Input b – Switching sequence: {{0}}Value 3: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
80Input b – Switching sequence: {{0}}Value 3: HVAC mode1 Byte20.102 HVAC modeCWTU
80Input b – Pulse counter 1: {{0}}Request counter value1 Bit1.17 triggerCW
81Input b – Switch: {{0}}Block 21 Bit1.3 enableCW
81Input b – Blind/shutter: {{0}}Status Upper end position1 Bit1.2 booleanCWU
81Input b – Switch/dim: {{0}}Block1 Bit1.3 enableCW
81Input b – Send value: {{0}}Value 4: Switch1 Bit1.1 switchCWTU
81Input b – Send value: {{0}}Value 4: Percent1 Byte5.1 percentage (0..100%)CWTU
81Input b – Send value: {{0}}Value 4: Forced operation2 Bit2.1 switch controlCWTU
81Input b – Send value: {{0}}Value 4: Temperature2 Bytes9.1 temperature (°C)CWTU
81Input b – Send value: {{0}}Value 4: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
81Input b – Send value: {{0}}Value 4: HVAC mode1 Byte20.102 HVAC modeCWTU
81Input b – Send value: {{0}}Value 4: 1 byte1 Byte5.10 counter pulses (0..255)CWTU
81Input b – Send value: {{0}}Value 4: 1 byte signed1 Byte6.10 counter pulses (-128..127)CWTU
81Input b – Send value: {{0}}Value 4: 2 bytes2 Bytes7.1 pulsesCWTU
81Input b – Send value: {{0}}Value 4: 2 bytes signed2 Bytes8.1 pulses differenceCWTU
81Input b – Send value: {{0}}Value 4: 4 bytes4 Bytes12.1 counter pulses (unsigned)CWTU
81Input b – Switching sequence: {{0}}Value 4: Switch1 Bit1.1 switchCWTU
81Input b – Switching sequence: {{0}}Value 4: Percent1 Byte5.1 percentage (0..100%)CWTU
81Input b – Switching sequence: {{0}}Value 4: Byte1 Byte5.10 counter pulses (0..255)CWTU
81Input b – Switching sequence: {{0}}Value 4: Scene1 Byte18.1 scene controlCWTU
81Input b – Switching sequence: {{0}}Value 4: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
81Input b – Switching sequence: {{0}}Value 4: HVAC mode1 Byte20.102 HVAC modeCWTU
81Input b – Pulse counter 1: {{0}}Limit value reached1 Bit1.2 booleanCRT
82Input b – Blind/shutter: {{0}}Status Lower end position1 Bit1.2 booleanCWU
82Input b – Send value: {{0}}Block1 Bit1.3 enableCWTU
82Input b – Switching sequence: {{0}}Value 5: Switch1 Bit1.1 switchCWTU
82Input b – Switching sequence: {{0}}Value 5: Percent1 Byte5.1 percentage (0..100%)CWTU
82Input b – Switching sequence: {{0}}Value 5: Byte1 Byte5.10 counter pulses (0..255)CWTU
82Input b – Switching sequence: {{0}}Value 5: Scene1 Byte18.1 scene controlCWTU
82Input b – Switching sequence: {{0}}Value 5: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
82Input b – Switching sequence: {{0}}Value 5: HVAC mode1 Byte20.102 HVAC modeCWTU
82Input b – Pulse counter 2: {{0}}Counter value1 Byte6.10 counter pulses (-128..127)CRT
82Input b – Pulse counter 2: {{0}}Counter value1 Byte5.10 counter pulses (0..255)CRT
82Input b – Pulse counter 2: {{0}}Counter value2 Bytes8.1 pulses differenceCRT
82Input b – Pulse counter 2: {{0}}Counter value2 Bytes7.1 pulsesCRT
82Input b – Pulse counter 2: {{0}}Counter value4 Bytes13.1 counter pulses (signed)CRT
82Input b – Pulse counter 2: {{0}}Counter value4 Bytes12.1 counter pulses (unsigned)CRT
83Input b – Blind/shutter: {{0}}Status Move1 Bit1.2 booleanCWU
83Input b – Switching sequence: {{0}}Number of operations1 Byte5.10 counter pulses (0..255)CWTU
83Input b – Pulse counter 2: {{0}}Reset counter value1 Bit1.15 resetCW
84Input b – Blind/shutter: {{0}}Block1 Bit1.3 enableCW
84Input b – Switching sequence: {{0}}Reset switching sequence1 Bit1.17 triggerCW
84Input b – Pulse counter 2: {{0}}Request counter value1 Bit1.17 triggerCW
85Input b – Switching sequence: {{0}}Next/previous step1 Bit1.7 stepCW
85Input b – Pulse counter 2: {{0}}Limit value reached1 Bit1.2 booleanCRT
86Input b – Switching sequence: {{0}}Block1 Bit1.3 enableCW
86Input b – Pulse counter: {{0}}Block1 Bit1.3 enableCW
87Input c – Switch: {{0}}Switch1 Bit1.1 switchCWTU
87Input c+d – Switch: {{0}}Switch1 Bit1.1 switchCWTU
87Input c – Blind/shutter: {{0}}Up/down1 Bit1.8 up/downCWTU
87Input c+d – Blind/shutter: {{0}}Up/down1 Bit1.8 up/downCWTU
87Input c – Switch/dim: {{0}}Dimming4 Bit3.7 dimming controlCT
87Input c+d – Switch/dim: {{0}}Dimming4 Bit3.7 dimming controlCT
87Input c – Scene: {{0}}Scene 1…641 Byte18.1 scene controlCT
87Input c – Send value: {{0}}Value 1: Switch1 Bit1.1 switchCWTU
87Input c – Send value: {{0}}Value 1: Percent1 Byte5.1 percentage (0..100%)CWTU
87Input c – Send value: {{0}}Value 1: Forced operation2 Bit2.1 switch controlCRWT
87Input c – Send value: {{0}}Value 1: Temperature2 Bytes9.1 temperature (°C)CWTU
87Input c – Send value: {{0}}Value 1: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
87Input c – Send value: {{0}}Value 1: HVAC mode1 Byte20.102 HVAC modeCWTU
87Input c – Send value: {{0}}Value 1: 1 byte1 Byte5.10 counter pulses (0..255)CWTU
87Input c – Send value: {{0}}Value 1: 1 byte signed1 Byte6.10 counter pulses (-128..127)CWTU
87Input c – Send value: {{0}}Value 1: 2 bytes2 Bytes7.1 pulsesCWTU
87Input c – Send value: {{0}}Value 1: 2 bytes signed2 Bytes8.1 pulses differenceCWTU
87Input c – Send value: {{0}}Value 1: 4 bytes4 Bytes12.1 counter pulses (unsigned)CWTU
87Input c – Fault indicator/logic input: {{0}}Status Fault1 Bit1.11 stateCRWT
87Input c – Switching sequence: {{0}}Value 1: Switch1 Bit1.1 switchCWTU
87Input c – Switching sequence: {{0}}Value 1: Percent1 Byte5.1 percentage (0..100%)CWTU
87Input c – Switching sequence: {{0}}Value 1: Byte1 Byte5.10 counter pulses (0..255)CWTU
87Input c – Switching sequence: {{0}}Value 1: Scene1 Byte18.1 scene controlCWTU
87Input c – Switching sequence: {{0}}Value 1: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
87Input c – Switching sequence: {{0}}Value 1: HVAC mode1 Byte20.102 HVAC modeCWTU
87Input c+d – Switching sequence: {{0}}Value 1: Switch1 Bit1.1 switchCWTU
87Input c+d – Switching sequence: {{0}}Value 1: Percent1 Byte5.1 percentage (0..100%)CWTU
87Input c+d – Switching sequence: {{0}}Value 1: Byte1 Byte5.10 counter pulses (0..255)CWTU
87Input c+d – Switching sequence: {{0}}Value 1: Scene1 Byte18.1 scene controlCWTU
87Input c+d – Switching sequence: {{0}}Value 1: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
87Input c+d – Switching sequence: {{0}}Value 1: HVAC mode1 Byte20.102 HVAC modeCWTU
87Input c – Pulse counter 1: {{0}}Counter value1 Byte6.10 counter pulses (-128..127)CRT
87Input c – Pulse counter 1: {{0}}Counter value1 Byte5.10 counter pulses (0..255)CRT
87Input c – Pulse counter 1: {{0}}Counter value2 Bytes8.1 pulses differenceCRT
87Input c – Pulse counter 1: {{0}}Counter value2 Bytes7.1 pulsesCRT
87Input c – Pulse counter 1: {{0}}Counter value4 Bytes13.1 counter pulses (signed)CRT
87Input c – Pulse counter 1: {{0}}Counter value4 Bytes12.1 counter pulses (unsigned)CRT
88Input c – Switch: {{0}}Block1 Bit1.3 enableCW
88Input c+d – Switch: {{0}}Block1 Bit1.3 enableCW
88Input c – Blind/shutter: {{0}}Step/stop1 Bit1.7 stepCWTU
88Input c – Blind/shutter: {{0}}Stop1 Bit1.17 triggerCWTU
88Input c+d – Blind/shutter: {{0}}Step/stop1 Bit1.7 stepCWTU
88Input c+d – Blind/shutter: {{0}}Stop1 Bit1.17 triggerCWTU
88Input c – Switch/dim: {{0}}Switch1 Bit1.1 switchCWTU
88Input c+d – Switch/dim: {{0}}Switch1 Bit1.1 switchCWTU
88Input c – Scene: {{0}}Block1 Bit1.3 enableCW
88Input c – Send value: {{0}}Value 2: Switch1 Bit1.1 switchCWTU
88Input c – Send value: {{0}}Value 2: Percent1 Byte5.1 percentage (0..100%)CWTU
88Input c – Send value: {{0}}Value 2: Forced operation2 Bit2.1 switch controlCRWT
88Input c – Send value: {{0}}Value 2: Temperature2 Bytes9.1 temperature (°C)CWTU
88Input c – Send value: {{0}}Value 2: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
88Input c – Send value: {{0}}Value 2: HVAC mode1 Byte20.102 HVAC modeCWTU
88Input c – Send value: {{0}}Value 2: 1 byte1 Byte5.10 counter pulses (0..255)CWTU
88Input c – Send value: {{0}}Value 2: 1 byte signed1 Byte6.10 counter pulses (-128..127)CWTU
88Input c – Send value: {{0}}Value 2: 2 bytes2 Bytes7.1 pulsesCWTU
88Input c – Send value: {{0}}Value 2: 2 bytes signed2 Bytes8.1 pulses differenceCWTU
88Input c – Send value: {{0}}Value 2: 4 bytes4 Bytes12.1 counter pulses (unsigned)CWTU
88Input c – Fault indicator/logic input: {{0}}Block1 Bit1.3 enableCW
88Input c – Switching sequence: {{0}}Value 2: Switch1 Bit1.1 switchCWTU
88Input c – Switching sequence: {{0}}Value 2: Percent1 Byte5.1 percentage (0..100%)CWTU
88Input c – Switching sequence: {{0}}Value 2: Byte1 Byte5.10 counter pulses (0..255)CWTU
88Input c – Switching sequence: {{0}}Value 2: Scene1 Byte18.1 scene controlCWTU
88Input c – Switching sequence: {{0}}Value 2: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
88Input c – Switching sequence: {{0}}Value 2: HVAC mode1 Byte20.102 HVAC modeCWTU
88Input c+d – Switching sequence: {{0}}Value 2: Switch1 Bit1.1 switchCWTU
88Input c+d – Switching sequence: {{0}}Value 2: Percent1 Byte5.1 percentage (0..100%)CWTU
88Input c+d – Switching sequence: {{0}}Value 2: Byte1 Byte5.10 counter pulses (0..255)CWTU
88Input c+d – Switching sequence: {{0}}Value 2: Scene1 Byte18.1 scene controlCWTU
88Input c+d – Switching sequence: {{0}}Value 2: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
88Input c+d – Switching sequence: {{0}}Value 2: HVAC mode1 Byte20.102 HVAC modeCWTU
88Input c – Pulse counter 1: {{0}}Reset counter value1 Bit1.15 resetCW
89Input c – Switch: {{0}}Switch 21 Bit1.1 switchCWTU
89Input c+d – Blind/shutter: {{0}}Status Upper end position1 Bit1.2 booleanCWU
89Input c+d – Switch/dim: {{0}}Block1 Bit1.3 enableCW
89Input c – Send value: {{0}}Value 3: Switch1 Bit1.1 switchCWTU
89Input c – Send value: {{0}}Value 3: Percent1 Byte5.1 percentage (0..100%)CWTU
89Input c – Send value: {{0}}Value 3: Forced operation2 Bit2.1 switch controlCWTU
89Input c – Send value: {{0}}Value 3: Temperature2 Bytes9.1 temperature (°C)CWTU
89Input c – Send value: {{0}}Value 3: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
89Input c – Send value: {{0}}Value 3: HVAC mode1 Byte20.102 HVAC modeCWTU
89Input c – Send value: {{0}}Value 3: 1 byte1 Byte5.10 counter pulses (0..255)CWTU
89Input c – Send value: {{0}}Value 3: 1 byte signed1 Byte6.10 counter pulses (-128..127)CWTU
89Input c – Send value: {{0}}Value 3: 2 bytes2 Bytes7.1 pulsesCWTU
89Input c – Send value: {{0}}Value 3: 2 bytes signed2 Bytes8.1 pulses differenceCWTU
89Input c – Send value: {{0}}Value 3: 4 bytes4 Bytes12.1 counter pulses (unsigned)CWTU
89Input c – Fault indicator/logic input: {{0}}Request status Fault1 Bit1.17 triggerCW
89Input c – Switching sequence: {{0}}Value 3: Switch1 Bit1.1 switchCWTU
89Input c – Switching sequence: {{0}}Value 3: Percent1 Byte5.1 percentage (0..100%)CWTU
89Input c – Switching sequence: {{0}}Value 3: Byte1 Byte5.10 counter pulses (0..255)CWTU
89Input c – Switching sequence: {{0}}Value 3: Scene1 Byte18.1 scene controlCWTU
89Input c – Switching sequence: {{0}}Value 3: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
89Input c – Switching sequence: {{0}}Value 3: HVAC mode1 Byte20.102 HVAC modeCWTU
89Input c+d – Switching sequence: {{0}}Value 3: Switch1 Bit1.1 switchCWTU
89Input c+d – Switching sequence: {{0}}Value 3: Percent1 Byte5.1 percentage (0..100%)CWTU
89Input c+d – Switching sequence: {{0}}Value 3: Byte1 Byte5.10 counter pulses (0..255)CWTU
89Input c+d – Switching sequence: {{0}}Value 3: Scene1 Byte18.1 scene controlCWTU
89Input c+d – Switching sequence: {{0}}Value 3: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
89Input c+d – Switching sequence: {{0}}Value 3: HVAC mode1 Byte20.102 HVAC modeCWTU
89Input c – Pulse counter 1: {{0}}Request counter value1 Bit1.17 triggerCW
90Input c – Switch: {{0}}Block 21 Bit1.3 enableCW
90Input c – Blind/shutter: {{0}}Status Upper end position1 Bit1.2 booleanCWU
90Input c+d – Blind/shutter: {{0}}Status Lower end position1 Bit1.2 booleanCWU
90Input c – Switch/dim: {{0}}Block1 Bit1.3 enableCW
90Input c – Send value: {{0}}Value 4: Switch1 Bit1.1 switchCWTU
90Input c – Send value: {{0}}Value 4: Percent1 Byte5.1 percentage (0..100%)CWTU
90Input c – Send value: {{0}}Value 4: Forced operation2 Bit2.1 switch controlCWTU
90Input c – Send value: {{0}}Value 4: Temperature2 Bytes9.1 temperature (°C)CWTU
90Input c – Send value: {{0}}Value 4: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
90Input c – Send value: {{0}}Value 4: HVAC mode1 Byte20.102 HVAC modeCWTU
90Input c – Send value: {{0}}Value 4: 1 byte1 Byte5.10 counter pulses (0..255)CWTU
90Input c – Send value: {{0}}Value 4: 1 byte signed1 Byte6.10 counter pulses (-128..127)CWTU
90Input c – Send value: {{0}}Value 4: 2 bytes2 Bytes7.1 pulsesCWTU
90Input c – Send value: {{0}}Value 4: 2 bytes signed2 Bytes8.1 pulses differenceCWTU
90Input c – Send value: {{0}}Value 4: 4 bytes4 Bytes12.1 counter pulses (unsigned)CWTU
90Input c – Switching sequence: {{0}}Value 4: Switch1 Bit1.1 switchCWTU
90Input c – Switching sequence: {{0}}Value 4: Percent1 Byte5.1 percentage (0..100%)CWTU
90Input c – Switching sequence: {{0}}Value 4: Byte1 Byte5.10 counter pulses (0..255)CWTU
90Input c – Switching sequence: {{0}}Value 4: Scene1 Byte18.1 scene controlCWTU
90Input c – Switching sequence: {{0}}Value 4: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
90Input c – Switching sequence: {{0}}Value 4: HVAC mode1 Byte20.102 HVAC modeCWTU
90Input c+d – Switching sequence: {{0}}Value 4: Switch1 Bit1.1 switchCWTU
90Input c+d – Switching sequence: {{0}}Value 4: Percent1 Byte5.1 percentage (0..100%)CWTU
90Input c+d – Switching sequence: {{0}}Value 4: Byte1 Byte5.10 counter pulses (0..255)CWTU
90Input c+d – Switching sequence: {{0}}Value 4: Scene1 Byte18.1 scene controlCWTU
90Input c+d – Switching sequence: {{0}}Value 4: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
90Input c+d – Switching sequence: {{0}}Value 4: HVAC mode1 Byte20.102 HVAC modeCWTU
90Input c – Pulse counter 1: {{0}}Limit value reached1 Bit1.2 booleanCRT
91Input c – Blind/shutter: {{0}}Status Lower end position1 Bit1.2 booleanCWU
91Input c+d – Blind/shutter: {{0}}Status Move1 Bit1.2 booleanCWU
91Input c – Send value: {{0}}Block1 Bit1.3 enableCWTU
91Input c – Switching sequence: {{0}}Value 5: Switch1 Bit1.1 switchCWTU
91Input c – Switching sequence: {{0}}Value 5: Percent1 Byte5.1 percentage (0..100%)CWTU
91Input c – Switching sequence: {{0}}Value 5: Byte1 Byte5.10 counter pulses (0..255)CWTU
91Input c – Switching sequence: {{0}}Value 5: Scene1 Byte18.1 scene controlCWTU
91Input c – Switching sequence: {{0}}Value 5: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
91Input c – Switching sequence: {{0}}Value 5: HVAC mode1 Byte20.102 HVAC modeCWTU
91Input c+d – Switching sequence: {{0}}Value 5: Switch1 Bit1.1 switchCWTU
91Input c+d – Switching sequence: {{0}}Value 5: Percent1 Byte5.1 percentage (0..100%)CWTU
91Input c+d – Switching sequence: {{0}}Value 5: Byte1 Byte5.10 counter pulses (0..255)CWTU
91Input c+d – Switching sequence: {{0}}Value 5: Scene1 Byte18.1 scene controlCWTU
91Input c+d – Switching sequence: {{0}}Value 5: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
91Input c+d – Switching sequence: {{0}}Value 5: HVAC mode1 Byte20.102 HVAC modeCWTU
91Input c – Pulse counter 2: {{0}}Counter value1 Byte6.10 counter pulses (-128..127)CRT
91Input c – Pulse counter 2: {{0}}Counter value1 Byte5.10 counter pulses (0..255)CRT
91Input c – Pulse counter 2: {{0}}Counter value2 Bytes8.1 pulses differenceCRT
91Input c – Pulse counter 2: {{0}}Counter value2 Bytes7.1 pulsesCRT
91Input c – Pulse counter 2: {{0}}Counter value4 Bytes13.1 counter pulses (signed)CRT
91Input c – Pulse counter 2: {{0}}Counter value4 Bytes12.1 counter pulses (unsigned)CRT
92Input c – Blind/shutter: {{0}}Status Move1 Bit1.2 booleanCWU
92Input c+d – Blind/shutter: {{0}}Block1 Bit1.3 enableCW
92Input c – Switching sequence: {{0}}Number of operations1 Byte5.10 counter pulses (0..255)CWTU
92Input c+d – Switching sequence: {{0}}Number of operations1 Byte5.10 counter pulses (0..255)CWTU
92Input c – Pulse counter 2: {{0}}Reset counter value1 Bit1.15 resetCW
93Input c – Blind/shutter: {{0}}Block1 Bit1.3 enableCW
93Input c – Switching sequence: {{0}}Reset switching sequence1 Bit1.17 triggerCW
93Input c+d – Switching sequence: {{0}}Reset switching sequence1 Bit1.17 triggerCW
93Input c – Pulse counter 2: {{0}}Request counter value1 Bit1.17 triggerCW
94Input c – Switching sequence: {{0}}Next/previous step1 Bit1.7 stepCW
94Input c+d – Switching sequence: {{0}}Next/previous step1 Bit1.7 stepCW
94Input c – Pulse counter 2: {{0}}Limit value reached1 Bit1.2 booleanCRT
95Input c – Switching sequence: {{0}}Block1 Bit1.3 enableCW
95Input c+d – Switching sequence: {{0}}Block1 Bit1.3 enableCW
95Input c – Pulse counter: {{0}}Block1 Bit1.3 enableCW
96Input d – Switch: {{0}}Switch1 Bit1.1 switchCWTU
96Input d – Blind/shutter: {{0}}Up/down1 Bit1.8 up/downCWTU
96Input d – Switch/dim: {{0}}Dimming4 Bit3.7 dimming controlCT
96Input d – Scene: {{0}}Scene 1…641 Byte18.1 scene controlCT
96Input d – Send value: {{0}}Value 1: Switch1 Bit1.1 switchCWTU
96Input d – Send value: {{0}}Value 1: Percent1 Byte5.1 percentage (0..100%)CWTU
96Input d – Send value: {{0}}Value 1: Forced operation2 Bit2.1 switch controlCRWT
96Input d – Send value: {{0}}Value 1: Temperature2 Bytes9.1 temperature (°C)CWTU
96Input d – Send value: {{0}}Value 1: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
96Input d – Send value: {{0}}Value 1: HVAC mode1 Byte20.102 HVAC modeCWTU
96Input d – Send value: {{0}}Value 1: 1 byte1 Byte5.10 counter pulses (0..255)CWTU
96Input d – Send value: {{0}}Value 1: 1 byte signed1 Byte6.10 counter pulses (-128..127)CWTU
96Input d – Send value: {{0}}Value 1: 2 bytes2 Bytes7.1 pulsesCWTU
96Input d – Send value: {{0}}Value 1: 2 bytes signed2 Bytes8.1 pulses differenceCWTU
96Input d – Send value: {{0}}Value 1: 4 bytes4 Bytes12.1 counter pulses (unsigned)CWTU
96Input d – Fault indicator/logic input: {{0}}Status Fault1 Bit1.11 stateCRWT
96Input d – Switching sequence: {{0}}Value 1: Switch1 Bit1.1 switchCWTU
96Input d – Switching sequence: {{0}}Value 1: Percent1 Byte5.1 percentage (0..100%)CWTU
96Input d – Switching sequence: {{0}}Value 1: Byte1 Byte5.10 counter pulses (0..255)CWTU
96Input d – Switching sequence: {{0}}Value 1: Scene1 Byte18.1 scene controlCWTU
96Input d – Switching sequence: {{0}}Value 1: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
96Input d – Switching sequence: {{0}}Value 1: HVAC mode1 Byte20.102 HVAC modeCWTU
96Input d – Pulse counter 1: {{0}}Counter value1 Byte6.10 counter pulses (-128..127)CRT
96Input d – Pulse counter 1: {{0}}Counter value1 Byte5.10 counter pulses (0..255)CRT
96Input d – Pulse counter 1: {{0}}Counter value2 Bytes8.1 pulses differenceCRT
96Input d – Pulse counter 1: {{0}}Counter value2 Bytes7.1 pulsesCRT
96Input d – Pulse counter 1: {{0}}Counter value4 Bytes13.1 counter pulses (signed)CRT
96Input d – Pulse counter 1: {{0}}Counter value4 Bytes12.1 counter pulses (unsigned)CRT
97Input d – Switch: {{0}}Block1 Bit1.3 enableCW
97Input d – Blind/shutter: {{0}}Step/stop1 Bit1.7 stepCWTU
97Input d – Blind/shutter: {{0}}Stop1 Bit1.17 triggerCWTU
97Input d – Switch/dim: {{0}}Switch1 Bit1.1 switchCWTU
97Input d – Scene: {{0}}Block1 Bit1.3 enableCW
97Input d – Send value: {{0}}Value 2: Switch1 Bit1.1 switchCWTU
97Input d – Send value: {{0}}Value 2: Percent1 Byte5.1 percentage (0..100%)CWTU
97Input d – Send value: {{0}}Value 2: Forced operation2 Bit2.1 switch controlCRWT
97Input d – Send value: {{0}}Value 2: Temperature2 Bytes9.1 temperature (°C)CWTU
97Input d – Send value: {{0}}Value 2: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
97Input d – Send value: {{0}}Value 2: HVAC mode1 Byte20.102 HVAC modeCWTU
97Input d – Send value: {{0}}Value 2: 1 byte1 Byte5.10 counter pulses (0..255)CWTU
97Input d – Send value: {{0}}Value 2: 1 byte signed1 Byte6.10 counter pulses (-128..127)CWTU
97Input d – Send value: {{0}}Value 2: 2 bytes2 Bytes7.1 pulsesCWTU
97Input d – Send value: {{0}}Value 2: 2 bytes signed2 Bytes8.1 pulses differenceCWTU
97Input d – Send value: {{0}}Value 2: 4 bytes4 Bytes12.1 counter pulses (unsigned)CWTU
97Input d – Fault indicator/logic input: {{0}}Block1 Bit1.3 enableCW
97Input d – Switching sequence: {{0}}Value 2: Switch1 Bit1.1 switchCWTU
97Input d – Switching sequence: {{0}}Value 2: Percent1 Byte5.1 percentage (0..100%)CWTU
97Input d – Switching sequence: {{0}}Value 2: Byte1 Byte5.10 counter pulses (0..255)CWTU
97Input d – Switching sequence: {{0}}Value 2: Scene1 Byte18.1 scene controlCWTU
97Input d – Switching sequence: {{0}}Value 2: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
97Input d – Switching sequence: {{0}}Value 2: HVAC mode1 Byte20.102 HVAC modeCWTU
97Input d – Pulse counter 1: {{0}}Reset counter value1 Bit1.15 resetCW
98Input d – Switch: {{0}}Switch 21 Bit1.1 switchCWTU
98Input d – Send value: {{0}}Value 3: Switch1 Bit1.1 switchCWTU
98Input d – Send value: {{0}}Value 3: Percent1 Byte5.1 percentage (0..100%)CWTU
98Input d – Send value: {{0}}Value 3: Forced operation2 Bit2.1 switch controlCWTU
98Input d – Send value: {{0}}Value 3: Temperature2 Bytes9.1 temperature (°C)CWTU
98Input d – Send value: {{0}}Value 3: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
98Input d – Send value: {{0}}Value 3: HVAC mode1 Byte20.102 HVAC modeCWTU
98Input d – Send value: {{0}}Value 3: 1 byte1 Byte5.10 counter pulses (0..255)CWTU
98Input d – Send value: {{0}}Value 3: 1 byte signed1 Byte6.10 counter pulses (-128..127)CWTU
98Input d – Send value: {{0}}Value 3: 2 bytes2 Bytes7.1 pulsesCWTU
98Input d – Send value: {{0}}Value 3: 2 bytes signed2 Bytes8.1 pulses differenceCWTU
98Input d – Send value: {{0}}Value 3: 4 bytes4 Bytes12.1 counter pulses (unsigned)CWTU
98Input d – Fault indicator/logic input: {{0}}Request status Fault1 Bit1.17 triggerCW
98Input d – Switching sequence: {{0}}Value 3: Switch1 Bit1.1 switchCWTU
98Input d – Switching sequence: {{0}}Value 3: Percent1 Byte5.1 percentage (0..100%)CWTU
98Input d – Switching sequence: {{0}}Value 3: Byte1 Byte5.10 counter pulses (0..255)CWTU
98Input d – Switching sequence: {{0}}Value 3: Scene1 Byte18.1 scene controlCWTU
98Input d – Switching sequence: {{0}}Value 3: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
98Input d – Switching sequence: {{0}}Value 3: HVAC mode1 Byte20.102 HVAC modeCWTU
98Input d – Pulse counter 1: {{0}}Request counter value1 Bit1.17 triggerCW
99Input d – Switch: {{0}}Block 21 Bit1.3 enableCW
99Input d – Blind/shutter: {{0}}Status Upper end position1 Bit1.2 booleanCWU
99Input d – Switch/dim: {{0}}Block1 Bit1.3 enableCW
99Input d – Send value: {{0}}Value 4: Switch1 Bit1.1 switchCWTU
99Input d – Send value: {{0}}Value 4: Percent1 Byte5.1 percentage (0..100%)CWTU
99Input d – Send value: {{0}}Value 4: Forced operation2 Bit2.1 switch controlCWTU
99Input d – Send value: {{0}}Value 4: Temperature2 Bytes9.1 temperature (°C)CWTU
99Input d – Send value: {{0}}Value 4: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
99Input d – Send value: {{0}}Value 4: HVAC mode1 Byte20.102 HVAC modeCWTU
99Input d – Send value: {{0}}Value 4: 1 byte1 Byte5.10 counter pulses (0..255)CWTU
99Input d – Send value: {{0}}Value 4: 1 byte signed1 Byte6.10 counter pulses (-128..127)CWTU
99Input d – Send value: {{0}}Value 4: 2 bytes2 Bytes7.1 pulsesCWTU
99Input d – Send value: {{0}}Value 4: 2 bytes signed2 Bytes8.1 pulses differenceCWTU
99Input d – Send value: {{0}}Value 4: 4 bytes4 Bytes12.1 counter pulses (unsigned)CWTU
99Input d – Switching sequence: {{0}}Value 4: Switch1 Bit1.1 switchCWTU
99Input d – Switching sequence: {{0}}Value 4: Percent1 Byte5.1 percentage (0..100%)CWTU
99Input d – Switching sequence: {{0}}Value 4: Byte1 Byte5.10 counter pulses (0..255)CWTU
99Input d – Switching sequence: {{0}}Value 4: Scene1 Byte18.1 scene controlCWTU
99Input d – Switching sequence: {{0}}Value 4: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
99Input d – Switching sequence: {{0}}Value 4: HVAC mode1 Byte20.102 HVAC modeCWTU
99Input d – Pulse counter 1: {{0}}Limit value reached1 Bit1.2 booleanCRT
100Input d – Blind/shutter: {{0}}Status Lower end position1 Bit1.2 booleanCWU
100Input d – Send value: {{0}}Block1 Bit1.3 enableCWTU
100Input d – Switching sequence: {{0}}Value 5: Switch1 Bit1.1 switchCWTU
100Input d – Switching sequence: {{0}}Value 5: Percent1 Byte5.1 percentage (0..100%)CWTU
100Input d – Switching sequence: {{0}}Value 5: Byte1 Byte5.10 counter pulses (0..255)CWTU
100Input d – Switching sequence: {{0}}Value 5: Scene1 Byte18.1 scene controlCWTU
100Input d – Switching sequence: {{0}}Value 5: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
100Input d – Switching sequence: {{0}}Value 5: HVAC mode1 Byte20.102 HVAC modeCWTU
100Input d – Pulse counter 2: {{0}}Counter value1 Byte6.10 counter pulses (-128..127)CRT
100Input d – Pulse counter 2: {{0}}Counter value1 Byte5.10 counter pulses (0..255)CRT
100Input d – Pulse counter 2: {{0}}Counter value2 Bytes8.1 pulses differenceCRT
100Input d – Pulse counter 2: {{0}}Counter value2 Bytes7.1 pulsesCRT
100Input d – Pulse counter 2: {{0}}Counter value4 Bytes13.1 counter pulses (signed)CRT
100Input d – Pulse counter 2: {{0}}Counter value4 Bytes12.1 counter pulses (unsigned)CRT
101Input d – Blind/shutter: {{0}}Status Move1 Bit1.2 booleanCWU
101Input d – Switching sequence: {{0}}Number of operations1 Byte5.10 counter pulses (0..255)CWTU
101Input d – Pulse counter 2: {{0}}Reset counter value1 Bit1.15 resetCW
102Input d – Blind/shutter: {{0}}Block1 Bit1.3 enableCW
102Input d – Switching sequence: {{0}}Reset switching sequence1 Bit1.17 triggerCW
102Input d – Pulse counter 2: {{0}}Request counter value1 Bit1.17 triggerCW
103Input d – Switching sequence: {{0}}Next/previous step1 Bit1.7 stepCW
103Input d – Pulse counter 2: {{0}}Limit value reached1 Bit1.2 booleanCRT
104Input d – Switching sequence: {{0}}Block1 Bit1.3 enableCW
104Input d – Pulse counter: {{0}}Block1 Bit1.3 enableCW
105Input e – Switch: {{0}}Switch1 Bit1.1 switchCWTU
105Input e+f – Switch: {{0}}Switch1 Bit1.1 switchCWTU
105Input e – Blind/shutter: {{0}}Up/down1 Bit1.8 up/downCWTU
105Input e+f – Blind/shutter: {{0}}Up/down1 Bit1.8 up/downCWTU
105Input e – Switch/dim: {{0}}Dimming4 Bit3.7 dimming controlCT
105Input e+f – Switch/dim: {{0}}Dimming4 Bit3.7 dimming controlCT
105Input e – Scene: {{0}}Scene 1…641 Byte18.1 scene controlCT
105Input e – Send value: {{0}}Value 1: Switch1 Bit1.1 switchCWTU
105Input e – Send value: {{0}}Value 1: Percent1 Byte5.1 percentage (0..100%)CWTU
105Input e – Send value: {{0}}Value 1: Forced operation2 Bit2.1 switch controlCRWT
105Input e – Send value: {{0}}Value 1: Temperature2 Bytes9.1 temperature (°C)CWTU
105Input e – Send value: {{0}}Value 1: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
105Input e – Send value: {{0}}Value 1: HVAC mode1 Byte20.102 HVAC modeCWTU
105Input e – Send value: {{0}}Value 1: 1 byte1 Byte5.10 counter pulses (0..255)CWTU
105Input e – Send value: {{0}}Value 1: 1 byte signed1 Byte6.10 counter pulses (-128..127)CWTU
105Input e – Send value: {{0}}Value 1: 2 bytes2 Bytes7.1 pulsesCWTU
105Input e – Send value: {{0}}Value 1: 2 bytes signed2 Bytes8.1 pulses differenceCWTU
105Input e – Send value: {{0}}Value 1: 4 bytes4 Bytes12.1 counter pulses (unsigned)CWTU
105Input e – Fault indicator/logic input: {{0}}Status Fault1 Bit1.11 stateCRWT
105Input e – Switching sequence: {{0}}Value 1: Switch1 Bit1.1 switchCWTU
105Input e – Switching sequence: {{0}}Value 1: Percent1 Byte5.1 percentage (0..100%)CWTU
105Input e – Switching sequence: {{0}}Value 1: Byte1 Byte5.10 counter pulses (0..255)CWTU
105Input e – Switching sequence: {{0}}Value 1: Scene1 Byte18.1 scene controlCWTU
105Input e – Switching sequence: {{0}}Value 1: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
105Input e – Switching sequence: {{0}}Value 1: HVAC mode1 Byte20.102 HVAC modeCWTU
105Input e+f – Switching sequence: {{0}}Value 1: Switch1 Bit1.1 switchCWTU
105Input e+f – Switching sequence: {{0}}Value 1: Percent1 Byte5.1 percentage (0..100%)CWTU
105Input e+f – Switching sequence: {{0}}Value 1: Byte1 Byte5.10 counter pulses (0..255)CWTU
105Input e+f – Switching sequence: {{0}}Value 1: Scene1 Byte18.1 scene controlCWTU
105Input e+f – Switching sequence: {{0}}Value 1: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
105Input e+f – Switching sequence: {{0}}Value 1: HVAC mode1 Byte20.102 HVAC modeCWTU
105Input e – Pulse counter 1: {{0}}Counter value1 Byte6.10 counter pulses (-128..127)CRT
105Input e – Pulse counter 1: {{0}}Counter value1 Byte5.10 counter pulses (0..255)CRT
105Input e – Pulse counter 1: {{0}}Counter value2 Bytes8.1 pulses differenceCRT
105Input e – Pulse counter 1: {{0}}Counter value2 Bytes7.1 pulsesCRT
105Input e – Pulse counter 1: {{0}}Counter value4 Bytes13.1 counter pulses (signed)CRT
105Input e – Pulse counter 1: {{0}}Counter value4 Bytes12.1 counter pulses (unsigned)CRT
106Input e – Switch: {{0}}Block1 Bit1.3 enableCW
106Input e+f – Switch: {{0}}Block1 Bit1.3 enableCW
106Input e – Blind/shutter: {{0}}Step/stop1 Bit1.7 stepCWTU
106Input e – Blind/shutter: {{0}}Stop1 Bit1.17 triggerCWTU
106Input e+f – Blind/shutter: {{0}}Step/stop1 Bit1.7 stepCWTU
106Input e+f – Blind/shutter: {{0}}Stop1 Bit1.17 triggerCWTU
106Input e – Switch/dim: {{0}}Switch1 Bit1.1 switchCWTU
106Input e+f – Switch/dim: {{0}}Switch1 Bit1.1 switchCWTU
106Input e – Scene: {{0}}Block1 Bit1.3 enableCW
106Input e – Send value: {{0}}Value 2: Switch1 Bit1.1 switchCWTU
106Input e – Send value: {{0}}Value 2: Percent1 Byte5.1 percentage (0..100%)CWTU
106Input e – Send value: {{0}}Value 2: Forced operation2 Bit2.1 switch controlCRWT
106Input e – Send value: {{0}}Value 2: Temperature2 Bytes9.1 temperature (°C)CWTU
106Input e – Send value: {{0}}Value 2: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
106Input e – Send value: {{0}}Value 2: HVAC mode1 Byte20.102 HVAC modeCWTU
106Input e – Send value: {{0}}Value 2: 1 byte1 Byte5.10 counter pulses (0..255)CWTU
106Input e – Send value: {{0}}Value 2: 1 byte signed1 Byte6.10 counter pulses (-128..127)CWTU
106Input e – Send value: {{0}}Value 2: 2 bytes2 Bytes7.1 pulsesCWTU
106Input e – Send value: {{0}}Value 2: 2 bytes signed2 Bytes8.1 pulses differenceCWTU
106Input e – Send value: {{0}}Value 2: 4 bytes4 Bytes12.1 counter pulses (unsigned)CWTU
106Input e – Fault indicator/logic input: {{0}}Block1 Bit1.3 enableCW
106Input e – Switching sequence: {{0}}Value 2: Switch1 Bit1.1 switchCWTU
106Input e – Switching sequence: {{0}}Value 2: Percent1 Byte5.1 percentage (0..100%)CWTU
106Input e – Switching sequence: {{0}}Value 2: Byte1 Byte5.10 counter pulses (0..255)CWTU
106Input e – Switching sequence: {{0}}Value 2: Scene1 Byte18.1 scene controlCWTU
106Input e – Switching sequence: {{0}}Value 2: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
106Input e – Switching sequence: {{0}}Value 2: HVAC mode1 Byte20.102 HVAC modeCWTU
106Input e+f – Switching sequence: {{0}}Value 2: Switch1 Bit1.1 switchCWTU
106Input e+f – Switching sequence: {{0}}Value 2: Percent1 Byte5.1 percentage (0..100%)CWTU
106Input e+f – Switching sequence: {{0}}Value 2: Byte1 Byte5.10 counter pulses (0..255)CWTU
106Input e+f – Switching sequence: {{0}}Value 2: Scene1 Byte18.1 scene controlCWTU
106Input e+f – Switching sequence: {{0}}Value 2: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
106Input e+f – Switching sequence: {{0}}Value 2: HVAC mode1 Byte20.102 HVAC modeCWTU
106Input e – Pulse counter 1: {{0}}Reset counter value1 Bit1.15 resetCW
107Input e – Switch: {{0}}Switch 21 Bit1.1 switchCWTU
107Input e+f – Blind/shutter: {{0}}Status Upper end position1 Bit1.2 booleanCWU
107Input e+f – Switch/dim: {{0}}Block1 Bit1.3 enableCW
107Input e – Send value: {{0}}Value 3: Switch1 Bit1.1 switchCWTU
107Input e – Send value: {{0}}Value 3: Percent1 Byte5.1 percentage (0..100%)CWTU
107Input e – Send value: {{0}}Value 3: Forced operation2 Bit2.1 switch controlCWTU
107Input e – Send value: {{0}}Value 3: Temperature2 Bytes9.1 temperature (°C)CWTU
107Input e – Send value: {{0}}Value 3: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
107Input e – Send value: {{0}}Value 3: HVAC mode1 Byte20.102 HVAC modeCWTU
107Input e – Send value: {{0}}Value 3: 1 byte1 Byte5.10 counter pulses (0..255)CWTU
107Input e – Send value: {{0}}Value 3: 1 byte signed1 Byte6.10 counter pulses (-128..127)CWTU
107Input e – Send value: {{0}}Value 3: 2 bytes2 Bytes7.1 pulsesCWTU
107Input e – Send value: {{0}}Value 3: 2 bytes signed2 Bytes8.1 pulses differenceCWTU
107Input e – Send value: {{0}}Value 3: 4 bytes4 Bytes12.1 counter pulses (unsigned)CWTU
107Input e – Fault indicator/logic input: {{0}}Request status Fault1 Bit1.17 triggerCW
107Input e – Switching sequence: {{0}}Value 3: Switch1 Bit1.1 switchCWTU
107Input e – Switching sequence: {{0}}Value 3: Percent1 Byte5.1 percentage (0..100%)CWTU
107Input e – Switching sequence: {{0}}Value 3: Byte1 Byte5.10 counter pulses (0..255)CWTU
107Input e – Switching sequence: {{0}}Value 3: Scene1 Byte18.1 scene controlCWTU
107Input e – Switching sequence: {{0}}Value 3: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
107Input e – Switching sequence: {{0}}Value 3: HVAC mode1 Byte20.102 HVAC modeCWTU
107Input e+f – Switching sequence: {{0}}Value 3: Switch1 Bit1.1 switchCWTU
107Input e+f – Switching sequence: {{0}}Value 3: Percent1 Byte5.1 percentage (0..100%)CWTU
107Input e+f – Switching sequence: {{0}}Value 3: Byte1 Byte5.10 counter pulses (0..255)CWTU
107Input e+f – Switching sequence: {{0}}Value 3: Scene1 Byte18.1 scene controlCWTU
107Input e+f – Switching sequence: {{0}}Value 3: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
107Input e+f – Switching sequence: {{0}}Value 3: HVAC mode1 Byte20.102 HVAC modeCWTU
107Input e – Pulse counter 1: {{0}}Request counter value1 Bit1.17 triggerCW
108Input e – Switch: {{0}}Block 21 Bit1.3 enableCW
108Input e – Blind/shutter: {{0}}Status Upper end position1 Bit1.2 booleanCWU
108Input e+f – Blind/shutter: {{0}}Status Lower end position1 Bit1.2 booleanCWU
108Input e – Switch/dim: {{0}}Block1 Bit1.3 enableCW
108Input e – Send value: {{0}}Value 4: Switch1 Bit1.1 switchCWTU
108Input e – Send value: {{0}}Value 4: Percent1 Byte5.1 percentage (0..100%)CWTU
108Input e – Send value: {{0}}Value 4: Forced operation2 Bit2.1 switch controlCWTU
108Input e – Send value: {{0}}Value 4: Temperature2 Bytes9.1 temperature (°C)CWTU
108Input e – Send value: {{0}}Value 4: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
108Input e – Send value: {{0}}Value 4: HVAC mode1 Byte20.102 HVAC modeCWTU
108Input e – Send value: {{0}}Value 4: 1 byte1 Byte5.10 counter pulses (0..255)CWTU
108Input e – Send value: {{0}}Value 4: 1 byte signed1 Byte6.10 counter pulses (-128..127)CWTU
108Input e – Send value: {{0}}Value 4: 2 bytes2 Bytes7.1 pulsesCWTU
108Input e – Send value: {{0}}Value 4: 2 bytes signed2 Bytes8.1 pulses differenceCWTU
108Input e – Send value: {{0}}Value 4: 4 bytes4 Bytes12.1 counter pulses (unsigned)CWTU
108Input e – Switching sequence: {{0}}Value 4: Switch1 Bit1.1 switchCWTU
108Input e – Switching sequence: {{0}}Value 4: Percent1 Byte5.1 percentage (0..100%)CWTU
108Input e – Switching sequence: {{0}}Value 4: Byte1 Byte5.10 counter pulses (0..255)CWTU
108Input e – Switching sequence: {{0}}Value 4: Scene1 Byte18.1 scene controlCWTU
108Input e – Switching sequence: {{0}}Value 4: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
108Input e – Switching sequence: {{0}}Value 4: HVAC mode1 Byte20.102 HVAC modeCWTU
108Input e+f – Switching sequence: {{0}}Value 4: Switch1 Bit1.1 switchCWTU
108Input e+f – Switching sequence: {{0}}Value 4: Percent1 Byte5.1 percentage (0..100%)CWTU
108Input e+f – Switching sequence: {{0}}Value 4: Byte1 Byte5.10 counter pulses (0..255)CWTU
108Input e+f – Switching sequence: {{0}}Value 4: Scene1 Byte18.1 scene controlCWTU
108Input e+f – Switching sequence: {{0}}Value 4: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
108Input e+f – Switching sequence: {{0}}Value 4: HVAC mode1 Byte20.102 HVAC modeCWTU
108Input e – Pulse counter 1: {{0}}Limit value reached1 Bit1.2 booleanCRT
109Input e – Blind/shutter: {{0}}Status Lower end position1 Bit1.2 booleanCWU
109Input e+f – Blind/shutter: {{0}}Status Move1 Bit1.2 booleanCWU
109Input e – Send value: {{0}}Block1 Bit1.3 enableCWTU
109Input e – Switching sequence: {{0}}Value 5: Switch1 Bit1.1 switchCWTU
109Input e – Switching sequence: {{0}}Value 5: Percent1 Byte5.1 percentage (0..100%)CWTU
109Input e – Switching sequence: {{0}}Value 5: Byte1 Byte5.10 counter pulses (0..255)CWTU
109Input e – Switching sequence: {{0}}Value 5: Scene1 Byte18.1 scene controlCWTU
109Input e – Switching sequence: {{0}}Value 5: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
109Input e – Switching sequence: {{0}}Value 5: HVAC mode1 Byte20.102 HVAC modeCWTU
109Input e+f – Switching sequence: {{0}}Value 5: Switch1 Bit1.1 switchCWTU
109Input e+f – Switching sequence: {{0}}Value 5: Percent1 Byte5.1 percentage (0..100%)CWTU
109Input e+f – Switching sequence: {{0}}Value 5: Byte1 Byte5.10 counter pulses (0..255)CWTU
109Input e+f – Switching sequence: {{0}}Value 5: Scene1 Byte18.1 scene controlCWTU
109Input e+f – Switching sequence: {{0}}Value 5: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
109Input e+f – Switching sequence: {{0}}Value 5: HVAC mode1 Byte20.102 HVAC modeCWTU
109Input e – Pulse counter 2: {{0}}Counter value1 Byte6.10 counter pulses (-128..127)CRT
109Input e – Pulse counter 2: {{0}}Counter value1 Byte5.10 counter pulses (0..255)CRT
109Input e – Pulse counter 2: {{0}}Counter value2 Bytes8.1 pulses differenceCRT
109Input e – Pulse counter 2: {{0}}Counter value2 Bytes7.1 pulsesCRT
109Input e – Pulse counter 2: {{0}}Counter value4 Bytes13.1 counter pulses (signed)CRT
109Input e – Pulse counter 2: {{0}}Counter value4 Bytes12.1 counter pulses (unsigned)CRT
110Input e – Blind/shutter: {{0}}Status Move1 Bit1.2 booleanCWU
110Input e+f – Blind/shutter: {{0}}Block1 Bit1.3 enableCW
110Input e – Switching sequence: {{0}}Number of operations1 Byte5.10 counter pulses (0..255)CWTU
110Input e+f – Switching sequence: {{0}}Number of operations1 Byte5.10 counter pulses (0..255)CWTU
110Input e – Pulse counter 2: {{0}}Reset counter value1 Bit1.15 resetCW
111Input e – Blind/shutter: {{0}}Block1 Bit1.3 enableCW
111Input e – Switching sequence: {{0}}Reset switching sequence1 Bit1.17 triggerCW
111Input e+f – Switching sequence: {{0}}Reset switching sequence1 Bit1.17 triggerCW
111Input e – Pulse counter 2: {{0}}Request counter value1 Bit1.17 triggerCW
112Input e – Switching sequence: {{0}}Next/previous step1 Bit1.7 stepCW
112Input e+f – Switching sequence: {{0}}Next/previous step1 Bit1.7 stepCW
112Input e – Pulse counter 2: {{0}}Limit value reached1 Bit1.2 booleanCRT
113Input e – Switching sequence: {{0}}Block1 Bit1.3 enableCW
113Input e+f – Switching sequence: {{0}}Block1 Bit1.3 enableCW
113Input e – Pulse counter: {{0}}Block1 Bit1.3 enableCW
114Input f – Switch: {{0}}Switch1 Bit1.1 switchCWTU
114Input f – Blind/shutter: {{0}}Up/down1 Bit1.8 up/downCWTU
114Input f – Switch/dim: {{0}}Dimming4 Bit3.7 dimming controlCT
114Input f – Scene: {{0}}Scene 1…641 Byte18.1 scene controlCT
114Input f – Send value: {{0}}Value 1: Switch1 Bit1.1 switchCWTU
114Input f – Send value: {{0}}Value 1: Percent1 Byte5.1 percentage (0..100%)CWTU
114Input f – Send value: {{0}}Value 1: Forced operation2 Bit2.1 switch controlCRWT
114Input f – Send value: {{0}}Value 1: Temperature2 Bytes9.1 temperature (°C)CWTU
114Input f – Send value: {{0}}Value 1: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
114Input f – Send value: {{0}}Value 1: HVAC mode1 Byte20.102 HVAC modeCWTU
114Input f – Send value: {{0}}Value 1: 1 byte1 Byte5.10 counter pulses (0..255)CWTU
114Input f – Send value: {{0}}Value 1: 1 byte signed1 Byte6.10 counter pulses (-128..127)CWTU
114Input f – Send value: {{0}}Value 1: 2 bytes2 Bytes7.1 pulsesCWTU
114Input f – Send value: {{0}}Value 1: 2 bytes signed2 Bytes8.1 pulses differenceCWTU
114Input f – Send value: {{0}}Value 1: 4 bytes4 Bytes12.1 counter pulses (unsigned)CWTU
114Input f – Fault indicator/logic input: {{0}}Status Fault1 Bit1.11 stateCRWT
114Input f – Switching sequence: {{0}}Value 1: Switch1 Bit1.1 switchCWTU
114Input f – Switching sequence: {{0}}Value 1: Percent1 Byte5.1 percentage (0..100%)CWTU
114Input f – Switching sequence: {{0}}Value 1: Byte1 Byte5.10 counter pulses (0..255)CWTU
114Input f – Switching sequence: {{0}}Value 1: Scene1 Byte18.1 scene controlCWTU
114Input f – Switching sequence: {{0}}Value 1: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
114Input f – Switching sequence: {{0}}Value 1: HVAC mode1 Byte20.102 HVAC modeCWTU
114Input f – Pulse counter 1: {{0}}Counter value1 Byte6.10 counter pulses (-128..127)CRT
114Input f – Pulse counter 1: {{0}}Counter value1 Byte5.10 counter pulses (0..255)CRT
114Input f – Pulse counter 1: {{0}}Counter value2 Bytes8.1 pulses differenceCRT
114Input f – Pulse counter 1: {{0}}Counter value2 Bytes7.1 pulsesCRT
114Input f – Pulse counter 1: {{0}}Counter value4 Bytes13.1 counter pulses (signed)CRT
114Input f – Pulse counter 1: {{0}}Counter value4 Bytes12.1 counter pulses (unsigned)CRT
115Input f – Switch: {{0}}Block1 Bit1.3 enableCW
115Input f – Blind/shutter: {{0}}Step/stop1 Bit1.7 stepCWTU
115Input f – Blind/shutter: {{0}}Stop1 Bit1.17 triggerCWTU
115Input f – Switch/dim: {{0}}Switch1 Bit1.1 switchCWTU
115Input f – Scene: {{0}}Block1 Bit1.3 enableCW
115Input f – Send value: {{0}}Value 2: Switch1 Bit1.1 switchCWTU
115Input f – Send value: {{0}}Value 2: Percent1 Byte5.1 percentage (0..100%)CWTU
115Input f – Send value: {{0}}Value 2: Forced operation2 Bit2.1 switch controlCRWT
115Input f – Send value: {{0}}Value 2: Temperature2 Bytes9.1 temperature (°C)CWTU
115Input f – Send value: {{0}}Value 2: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
115Input f – Send value: {{0}}Value 2: HVAC mode1 Byte20.102 HVAC modeCWTU
115Input f – Send value: {{0}}Value 2: 1 byte1 Byte5.10 counter pulses (0..255)CWTU
115Input f – Send value: {{0}}Value 2: 1 byte signed1 Byte6.10 counter pulses (-128..127)CWTU
115Input f – Send value: {{0}}Value 2: 2 bytes2 Bytes7.1 pulsesCWTU
115Input f – Send value: {{0}}Value 2: 2 bytes signed2 Bytes8.1 pulses differenceCWTU
115Input f – Send value: {{0}}Value 2: 4 bytes4 Bytes12.1 counter pulses (unsigned)CWTU
115Input f – Fault indicator/logic input: {{0}}Block1 Bit1.3 enableCW
115Input f – Switching sequence: {{0}}Value 2: Switch1 Bit1.1 switchCWTU
115Input f – Switching sequence: {{0}}Value 2: Percent1 Byte5.1 percentage (0..100%)CWTU
115Input f – Switching sequence: {{0}}Value 2: Byte1 Byte5.10 counter pulses (0..255)CWTU
115Input f – Switching sequence: {{0}}Value 2: Scene1 Byte18.1 scene controlCWTU
115Input f – Switching sequence: {{0}}Value 2: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
115Input f – Switching sequence: {{0}}Value 2: HVAC mode1 Byte20.102 HVAC modeCWTU
115Input f – Pulse counter 1: {{0}}Reset counter value1 Bit1.15 resetCW
116Input f – Switch: {{0}}Switch 21 Bit1.1 switchCWTU
116Input f – Send value: {{0}}Value 3: Switch1 Bit1.1 switchCWTU
116Input f – Send value: {{0}}Value 3: Percent1 Byte5.1 percentage (0..100%)CWTU
116Input f – Send value: {{0}}Value 3: Forced operation2 Bit2.1 switch controlCWTU
116Input f – Send value: {{0}}Value 3: Temperature2 Bytes9.1 temperature (°C)CWTU
116Input f – Send value: {{0}}Value 3: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
116Input f – Send value: {{0}}Value 3: HVAC mode1 Byte20.102 HVAC modeCWTU
116Input f – Send value: {{0}}Value 3: 1 byte1 Byte5.10 counter pulses (0..255)CWTU
116Input f – Send value: {{0}}Value 3: 1 byte signed1 Byte6.10 counter pulses (-128..127)CWTU
116Input f – Send value: {{0}}Value 3: 2 bytes2 Bytes7.1 pulsesCWTU
116Input f – Send value: {{0}}Value 3: 2 bytes signed2 Bytes8.1 pulses differenceCWTU
116Input f – Send value: {{0}}Value 3: 4 bytes4 Bytes12.1 counter pulses (unsigned)CWTU
116Input f – Fault indicator/logic input: {{0}}Request status Fault1 Bit1.17 triggerCW
116Input f – Switching sequence: {{0}}Value 3: Switch1 Bit1.1 switchCWTU
116Input f – Switching sequence: {{0}}Value 3: Percent1 Byte5.1 percentage (0..100%)CWTU
116Input f – Switching sequence: {{0}}Value 3: Byte1 Byte5.10 counter pulses (0..255)CWTU
116Input f – Switching sequence: {{0}}Value 3: Scene1 Byte18.1 scene controlCWTU
116Input f – Switching sequence: {{0}}Value 3: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
116Input f – Switching sequence: {{0}}Value 3: HVAC mode1 Byte20.102 HVAC modeCWTU
116Input f – Pulse counter 1: {{0}}Request counter value1 Bit1.17 triggerCW
117Input f – Switch: {{0}}Block 21 Bit1.3 enableCW
117Input f – Blind/shutter: {{0}}Status Upper end position1 Bit1.2 booleanCWU
117Input f – Switch/dim: {{0}}Block1 Bit1.3 enableCW
117Input f – Send value: {{0}}Value 4: Switch1 Bit1.1 switchCWTU
117Input f – Send value: {{0}}Value 4: Percent1 Byte5.1 percentage (0..100%)CWTU
117Input f – Send value: {{0}}Value 4: Forced operation2 Bit2.1 switch controlCWTU
117Input f – Send value: {{0}}Value 4: Temperature2 Bytes9.1 temperature (°C)CWTU
117Input f – Send value: {{0}}Value 4: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
117Input f – Send value: {{0}}Value 4: HVAC mode1 Byte20.102 HVAC modeCWTU
117Input f – Send value: {{0}}Value 4: 1 byte1 Byte5.10 counter pulses (0..255)CWTU
117Input f – Send value: {{0}}Value 4: 1 byte signed1 Byte6.10 counter pulses (-128..127)CWTU
117Input f – Send value: {{0}}Value 4: 2 bytes2 Bytes7.1 pulsesCWTU
117Input f – Send value: {{0}}Value 4: 2 bytes signed2 Bytes8.1 pulses differenceCWTU
117Input f – Send value: {{0}}Value 4: 4 bytes4 Bytes12.1 counter pulses (unsigned)CWTU
117Input f – Switching sequence: {{0}}Value 4: Switch1 Bit1.1 switchCWTU
117Input f – Switching sequence: {{0}}Value 4: Percent1 Byte5.1 percentage (0..100%)CWTU
117Input f – Switching sequence: {{0}}Value 4: Byte1 Byte5.10 counter pulses (0..255)CWTU
117Input f – Switching sequence: {{0}}Value 4: Scene1 Byte18.1 scene controlCWTU
117Input f – Switching sequence: {{0}}Value 4: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
117Input f – Switching sequence: {{0}}Value 4: HVAC mode1 Byte20.102 HVAC modeCWTU
117Input f – Pulse counter 1: {{0}}Limit value reached1 Bit1.2 booleanCRT
118Input f – Blind/shutter: {{0}}Status Lower end position1 Bit1.2 booleanCWU
118Input f – Send value: {{0}}Block1 Bit1.3 enableCWTU
118Input f – Switching sequence: {{0}}Value 5: Switch1 Bit1.1 switchCWTU
118Input f – Switching sequence: {{0}}Value 5: Percent1 Byte5.1 percentage (0..100%)CWTU
118Input f – Switching sequence: {{0}}Value 5: Byte1 Byte5.10 counter pulses (0..255)CWTU
118Input f – Switching sequence: {{0}}Value 5: Scene1 Byte18.1 scene controlCWTU
118Input f – Switching sequence: {{0}}Value 5: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
118Input f – Switching sequence: {{0}}Value 5: HVAC mode1 Byte20.102 HVAC modeCWTU
118Input f – Pulse counter 2: {{0}}Counter value1 Byte6.10 counter pulses (-128..127)CRT
118Input f – Pulse counter 2: {{0}}Counter value1 Byte5.10 counter pulses (0..255)CRT
118Input f – Pulse counter 2: {{0}}Counter value2 Bytes8.1 pulses differenceCRT
118Input f – Pulse counter 2: {{0}}Counter value2 Bytes7.1 pulsesCRT
118Input f – Pulse counter 2: {{0}}Counter value4 Bytes13.1 counter pulses (signed)CRT
118Input f – Pulse counter 2: {{0}}Counter value4 Bytes12.1 counter pulses (unsigned)CRT
119Input f – Blind/shutter: {{0}}Status Move1 Bit1.2 booleanCWU
119Input f – Switching sequence: {{0}}Number of operations1 Byte5.10 counter pulses (0..255)CWTU
119Input f – Pulse counter 2: {{0}}Reset counter value1 Bit1.15 resetCW
120Input f – Blind/shutter: {{0}}Block1 Bit1.3 enableCW
120Input f – Switching sequence: {{0}}Reset switching sequence1 Bit1.17 triggerCW
120Input f – Pulse counter 2: {{0}}Request counter value1 Bit1.17 triggerCW
121Input f – Switching sequence: {{0}}Next/previous step1 Bit1.7 stepCW
121Input f – Pulse counter 2: {{0}}Limit value reached1 Bit1.2 booleanCRT
122Input f – Switching sequence: {{0}}Block1 Bit1.3 enableCW
122Input f – Pulse counter: {{0}}Block1 Bit1.3 enableCW
123Input g – Switch: {{0}}Switch1 Bit1.1 switchCWTU
123Input g+h – Switch: {{0}}Switch1 Bit1.1 switchCWTU
123Input g – Blind/shutter: {{0}}Up/down1 Bit1.8 up/downCWTU
123Input g+h – Blind/shutter: {{0}}Up/down1 Bit1.8 up/downCWTU
123Input g – Switch/dim: {{0}}Dimming4 Bit3.7 dimming controlCT
123Input g+h – Switch/dim: {{0}}Dimming4 Bit3.7 dimming controlCT
123Input g – Scene: {{0}}Scene 1…641 Byte18.1 scene controlCT
123Input g – Send value: {{0}}Value 1: Switch1 Bit1.1 switchCWTU
123Input g – Send value: {{0}}Value 1: Percent1 Byte5.1 percentage (0..100%)CWTU
123Input g – Send value: {{0}}Value 1: Forced operation2 Bit2.1 switch controlCRWT
123Input g – Send value: {{0}}Value 1: Temperature2 Bytes9.1 temperature (°C)CWTU
123Input g – Send value: {{0}}Value 1: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
123Input g – Send value: {{0}}Value 1: HVAC mode1 Byte20.102 HVAC modeCWTU
123Input g – Send value: {{0}}Value 1: 1 byte1 Byte5.10 counter pulses (0..255)CWTU
123Input g – Send value: {{0}}Value 1: 1 byte signed1 Byte6.10 counter pulses (-128..127)CWTU
123Input g – Send value: {{0}}Value 1: 2 bytes2 Bytes7.1 pulsesCWTU
123Input g – Send value: {{0}}Value 1: 2 bytes signed2 Bytes8.1 pulses differenceCWTU
123Input g – Send value: {{0}}Value 1: 4 bytes4 Bytes12.1 counter pulses (unsigned)CWTU
123Input g – Fault indicator/logic input: {{0}}Status Fault1 Bit1.11 stateCRWT
123Input g – Switching sequence: {{0}}Value 1: Switch1 Bit1.1 switchCWTU
123Input g – Switching sequence: {{0}}Value 1: Percent1 Byte5.1 percentage (0..100%)CWTU
123Input g – Switching sequence: {{0}}Value 1: Byte1 Byte5.10 counter pulses (0..255)CWTU
123Input g – Switching sequence: {{0}}Value 1: Scene1 Byte18.1 scene controlCWTU
123Input g – Switching sequence: {{0}}Value 1: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
123Input g – Switching sequence: {{0}}Value 1: HVAC mode1 Byte20.102 HVAC modeCWTU
123Input g+h – Switching sequence: {{0}}Value 1: Switch1 Bit1.1 switchCWTU
123Input g+h – Switching sequence: {{0}}Value 1: Percent1 Byte5.1 percentage (0..100%)CWTU
123Input g+h – Switching sequence: {{0}}Value 1: Byte1 Byte5.10 counter pulses (0..255)CWTU
123Input g+h – Switching sequence: {{0}}Value 1: Scene1 Byte18.1 scene controlCWTU
123Input g+h – Switching sequence: {{0}}Value 1: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
123Input g+h – Switching sequence: {{0}}Value 1: HVAC mode1 Byte20.102 HVAC modeCWTU
123Input g – Pulse counter 1: {{0}}Counter value1 Byte6.10 counter pulses (-128..127)CRT
123Input g – Pulse counter 1: {{0}}Counter value1 Byte5.10 counter pulses (0..255)CRT
123Input g – Pulse counter 1: {{0}}Counter value2 Bytes8.1 pulses differenceCRT
123Input g – Pulse counter 1: {{0}}Counter value2 Bytes7.1 pulsesCRT
123Input g – Pulse counter 1: {{0}}Counter value4 Bytes13.1 counter pulses (signed)CRT
123Input g – Pulse counter 1: {{0}}Counter value4 Bytes12.1 counter pulses (unsigned)CRT
124Input g – Switch: {{0}}Block1 Bit1.3 enableCW
124Input g+h – Switch: {{0}}Block1 Bit1.3 enableCW
124Input g – Blind/shutter: {{0}}Step/stop1 Bit1.7 stepCWTU
124Input g – Blind/shutter: {{0}}Stop1 Bit1.17 triggerCWTU
124Input g+h – Blind/shutter: {{0}}Step/stop1 Bit1.7 stepCWTU
124Input g+h – Blind/shutter: {{0}}Stop1 Bit1.17 triggerCWTU
124Input g – Switch/dim: {{0}}Switch1 Bit1.1 switchCWTU
124Input g+h – Switch/dim: {{0}}Switch1 Bit1.1 switchCWTU
124Input g – Scene: {{0}}Block1 Bit1.3 enableCW
124Input g – Send value: {{0}}Value 2: Switch1 Bit1.1 switchCWTU
124Input g – Send value: {{0}}Value 2: Percent1 Byte5.1 percentage (0..100%)CWTU
124Input g – Send value: {{0}}Value 2: Forced operation2 Bit2.1 switch controlCRWT
124Input g – Send value: {{0}}Value 2: Temperature2 Bytes9.1 temperature (°C)CWTU
124Input g – Send value: {{0}}Value 2: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
124Input g – Send value: {{0}}Value 2: HVAC mode1 Byte20.102 HVAC modeCWTU
124Input g – Send value: {{0}}Value 2: 1 byte1 Byte5.10 counter pulses (0..255)CWTU
124Input g – Send value: {{0}}Value 2: 1 byte signed1 Byte6.10 counter pulses (-128..127)CWTU
124Input g – Send value: {{0}}Value 2: 2 bytes2 Bytes7.1 pulsesCWTU
124Input g – Send value: {{0}}Value 2: 2 bytes signed2 Bytes8.1 pulses differenceCWTU
124Input g – Send value: {{0}}Value 2: 4 bytes4 Bytes12.1 counter pulses (unsigned)CWTU
124Input g – Fault indicator/logic input: {{0}}Block1 Bit1.3 enableCW
124Input g – Switching sequence: {{0}}Value 2: Switch1 Bit1.1 switchCWTU
124Input g – Switching sequence: {{0}}Value 2: Percent1 Byte5.1 percentage (0..100%)CWTU
124Input g – Switching sequence: {{0}}Value 2: Byte1 Byte5.10 counter pulses (0..255)CWTU
124Input g – Switching sequence: {{0}}Value 2: Scene1 Byte18.1 scene controlCWTU
124Input g – Switching sequence: {{0}}Value 2: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
124Input g – Switching sequence: {{0}}Value 2: HVAC mode1 Byte20.102 HVAC modeCWTU
124Input g+h – Switching sequence: {{0}}Value 2: Switch1 Bit1.1 switchCWTU
124Input g+h – Switching sequence: {{0}}Value 2: Percent1 Byte5.1 percentage (0..100%)CWTU
124Input g+h – Switching sequence: {{0}}Value 2: Byte1 Byte5.10 counter pulses (0..255)CWTU
124Input g+h – Switching sequence: {{0}}Value 2: Scene1 Byte18.1 scene controlCWTU
124Input g+h – Switching sequence: {{0}}Value 2: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
124Input g+h – Switching sequence: {{0}}Value 2: HVAC mode1 Byte20.102 HVAC modeCWTU
124Input g – Pulse counter 1: {{0}}Reset counter value1 Bit1.15 resetCW
125Input g – Switch: {{0}}Switch 21 Bit1.1 switchCWTU
125Input g+h – Blind/shutter: {{0}}Status Upper end position1 Bit1.2 booleanCWU
125Input g+h – Switch/dim: {{0}}Block1 Bit1.3 enableCW
125Input g – Send value: {{0}}Value 3: Switch1 Bit1.1 switchCWTU
125Input g – Send value: {{0}}Value 3: Percent1 Byte5.1 percentage (0..100%)CWTU
125Input g – Send value: {{0}}Value 3: Forced operation2 Bit2.1 switch controlCWTU
125Input g – Send value: {{0}}Value 3: Temperature2 Bytes9.1 temperature (°C)CWTU
125Input g – Send value: {{0}}Value 3: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
125Input g – Send value: {{0}}Value 3: HVAC mode1 Byte20.102 HVAC modeCWTU
125Input g – Send value: {{0}}Value 3: 1 byte1 Byte5.10 counter pulses (0..255)CWTU
125Input g – Send value: {{0}}Value 3: 1 byte signed1 Byte6.10 counter pulses (-128..127)CWTU
125Input g – Send value: {{0}}Value 3: 2 bytes2 Bytes7.1 pulsesCWTU
125Input g – Send value: {{0}}Value 3: 2 bytes signed2 Bytes8.1 pulses differenceCWTU
125Input g – Send value: {{0}}Value 3: 4 bytes4 Bytes12.1 counter pulses (unsigned)CWTU
125Input g – Fault indicator/logic input: {{0}}Request status Fault1 Bit1.17 triggerCW
125Input g – Switching sequence: {{0}}Value 3: Switch1 Bit1.1 switchCWTU
125Input g – Switching sequence: {{0}}Value 3: Percent1 Byte5.1 percentage (0..100%)CWTU
125Input g – Switching sequence: {{0}}Value 3: Byte1 Byte5.10 counter pulses (0..255)CWTU
125Input g – Switching sequence: {{0}}Value 3: Scene1 Byte18.1 scene controlCWTU
125Input g – Switching sequence: {{0}}Value 3: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
125Input g – Switching sequence: {{0}}Value 3: HVAC mode1 Byte20.102 HVAC modeCWTU

First 1000 of 1468 group objects shown. Download the .knxprod for the full list.

Parameters (343)
ParameterTypeDefault
DevicelistBES
Signal typelistINTERNAL
Number of inputsunsignedInt 4…1610
Enable templatesunsignedInt 0…11
CalcParamunsignedInt 0…2550
Manual operationunsignedInt 0…11
Logic 1-4unsignedInt 0…11
Logic 5-8unsignedInt 0…11
Logic 9-12unsignedInt 0…11
Logic 13-16unsignedInt 0…10
1#Device settings$CentralunsignedInt 0…2550
2#Manual operation$CentralunsignedInt 0…2550
3#Logic$LogicunsignedInt 0…2550
4#TemplatesunsignedInt 0…2550
5#Input a||Input a+b$Input aunsignedInt 0…2550
6#Input b$Input bunsignedInt 0…2550
7#Input c||Input c+d$Input cunsignedInt 0…2550
8#Input d$Input dunsignedInt 0…2550
9#Input e||Input e+f$Input eunsignedInt 0…2550
10#Input f$Input funsignedInt 0…2550
11#Input g||Input g+h$Input gunsignedInt 0…2550
12#Input h$Input hunsignedInt 0…2550
13#Input i||Input i+j$Input iunsignedInt 0…2550
14#Input j$Input junsignedInt 0…2550
UCC_ENDunsignedInt 0…65535404
ApplicationlistDevice
Parameter SizeunsignedInt 0…655358
Sending delay after KNX voltage recoveryunsignedInt 2…602
Telegram rate limitunsignedInt 0…10
Maximum number of sent telegramsunsignedInt 0…10020
In periodunsignedInt 0…591
Access to i-bus ToollistFull access
Enable Group Object "In operation"listNo
Sending cycletime600
Enable Time Group Objects for setting of device timelistNo
Request Date/Time via Group ObjectunsignedInt 0…10
Config lengthunsignedInt 0…655350
ApplicationlistManualControl
Parameter SizeunsignedInt 0…655353
Enable manual operationunsignedInt 0…11
Automatic reset from manual operation to KNX operationunsignedInt 0…11
Automatic reset aftertime300
State after end of manual operationlistRefreshed KNX state
Config lengthunsignedInt 0…655353
ConfigunsignedInt 0…1677721532780
ApplicationlistLogic
Parameter SizeunsignedInt 0…6553560
Logic functionlistNone
Connection AlistDeactivated
Default setting "Connection A"listRead value
Connection BlistDeactivated
Default setting "Connection B"listRead value
Input alistApply value
Input blistApply value
Input clistDeactivated
Input dlistDeactivated
Input elistDeactivated
Input flistDeactivated
Input glistDeactivated
Input hlistDeactivated
Input ilistDeactivated
Input jlistDeactivated
Block logiclistDeactivated
State after ETS download or KNX voltage recoverylistLast state
Invert resultunsignedInt 0…10
Send "Status Result"listOn change
ApplicationlistSwitch template
Parameter SizeunsignedInt 0…6553529
DevicelistFTS
DevicelistUSU
Descriptiontext
Templates activatedunsignedInt 0…11
Templates activatedunsignedInt 0…10
Parameter settingunsignedInt 0…10
Distinction between short and long operationunsignedInt 0…10
Reaction on short operationlistOn
Reaction on long operationlistOff
Reaction on opening the contactlistOff
Reaction on closing the contactlistOn
Reaction when touchedlistToggle
Reaction on releaselistNo reaction
Send input status after ETS download or KNX voltage recoveryunsignedInt 0…10
Extended settingsunsignedInt 0…10
Enable function "Switch 2"unsignedInt 0…10
Enable function Switch 2unsignedInt 0…10
FunctionCodelistDIOCONF_PUSH_BUTTON_SENSOR
Contact typelistNO contact
Long operation aftertime400
Long operation afterunsignedInt 0…65535400
Signal typelistAutomatic
Interference suppression filterunsignedInt 12…15030
Interference suppression filterunsignedInt 60…15060
Block inputlistDeactivated
Block operating arealistDeactivated
Input buttonlistPush button reaction
Config lengthunsignedInt 0…6553515
ConfigunsignedInt 0…42949672950
ApplicationlistSwitch (2-button) template
Parameter SizeunsignedInt 0…6553527
Reaction on operationlistOn
Reaction on operationlistOff
Reaction on operationlistToggle
FunctionCodelistDIOCONF_PUSH_BUTTON_2_BUTTON_SENSOR
ConfigunsignedInt 0…655350
ApplicationlistBlind/shutter template
Parameter SizeunsignedInt 0…6553540
Operating modelistBlind
Blind operationlistShort: step/stop, long: move
Shutter operationlistShort: stop, long: move
Stop movementlistOn release
Cycle for sending the step/stop telegramtime500
Cycle for sending the Step/Stop telegramunsignedInt 0…65535500
"Movement" direction change aftertime0
"Slat" direction change aftertime5000
ApplicationlistBlind/shutter (2-button) template
Parameter SizeunsignedInt 0…6553532
Direction of movementlistUp
Direction of movementlistDown
ApplicationlistSwitch/dim template
On short operationlistToggle
On long operationlistChange dimming direction, darker when On
Dimming methodlistStart-stop-dimming
Dimming processlistStart-stop-dimming
Change per steplist3 %
Telegram is repeated everytime600
Telegram is repeated everyunsignedInt 0…65535600
ApplicationlistSwitch/dim (2-button) template
Parameter SizeunsignedInt 0…6553533
On short operationlistOn
On long operationlistBrighter
On short operationlistOff
On long operationlistDarker
ApplicationlistScenes template
Distinction between short and long operationunsignedInt 0…11
Scene numberunsignedInt 1…641
On short operation: Scene numberunsignedInt 1…641
ScenelistSend
Reaction on long operationlistSave scene
On long operation: Scene numberunsignedInt 1…641
Long operation aftertime3000
Long operation afterunsignedInt 0…655353000
ApplicationlistSend value/multiple operation template
Parameter SizeunsignedInt 0…6553556
Send value onlist1-fold operation
Toggle valueunsignedInt 0…10
Maximum time between two operationstime500
Maximum time between two operationsunsignedInt 0…65535500
Send values on every operationunsignedInt 0…10
On change of contact: DPTlistSwitch [DPT 1.001]
OperationlistClose
OperationlistToggle
There is text in the "Default value" columnlistShort operation
There is text in the "Default value" columnlist1-fold operation
On short operation: DPTlistSwitch [DPT 1.001]
On 1-fold operation: DPTlistSwitch [DPT 1.001]
Value 1 of Group Object "Value 1: Switch"listOn
Value 1 of Group Object "Value 1: Switch"listToggle
Value of Group Object "Value 1: Percent"unsignedInt 0…1000
Value of Group Object "Value 1: Percent"unsignedInt 0…2550
Value of Group Object "Value 1: Forced operation"listForced operation, value 1
Value of Group Object "Value 1: Temperature"signedInt -100…25020
Value of Group Object "Value 1: Temperature"signedInt -32768…327672000
Value of Group Object "Value 1: Color"color#000000
Value of Group Object "Value 1: HVAC mode"listAutomatic
Value of Group Object "Value 1: 1 byte"unsignedInt 0…2550
Value of Group Object "Value 1: 1 byte signed"signedInt -128…1270
Value of Group Object "Value 1: 2 bytes"unsignedInt 0…655350
Value of Group Object "Value 1: 2 bytes signed"signedInt -32768…327670
Value of Group Object "Value 1: 4 bytes"unsignedInt 0…42949672950
Value of Group Object "Value 3: Percent"unsignedInt 0…1000
Value of Group Object "Value 3: Percent"unsignedInt 0…2550
Value of Group Object "Value 3: Forced operation"listNo forced operation
Value of Group Object "Value 3: Temperature"signedInt -100…25020
Value of Group Object "Value 3: Temperature"signedInt -32768…327672000
Value of Group Object "Value 3: Color"color#000000
Value of Group Object "Value 3: HVAC mode"listAutomatic
Value of Group Object "Value 3: 1 byte"unsignedInt 0…2550
Value of Group Object "Value 3: 1 byte signed"signedInt -128…1270
Value of Group Object "Value 3: 2 bytes"unsignedInt 0…655350
Value of Group Object "Value 3: 2 bytes signed"signedInt -32768…327670
Value of Group Object "Value 3: 4 bytes"unsignedInt 0…42949672950
There is text in the "Default value" columnlistLong operation
There is text in the "Default value" columnlist2-fold operation
OperationlistNo reaction
On long operation: DPTlistSwitch [DPT 1.001]
On 2-fold operation: DPTlistSwitch [DPT 1.001]
Value 2 of Group Object "Value 1: Switch"listOff
Value 2 of Group Object "Value 1: Switch"listToggle
Value of Group Object "Value 2: Percent"unsignedInt 0…1000
Value of Group Object "Value 2: Percent"unsignedInt 0…2550
Value of Group Object "Value 2: Forced operation"listForced operation, value 0
Value of Group Object "Value 2: Temperature"signedInt -100…25020
Value of Group Object "Value 2: Temperature"signedInt -32768…327672000
Value of Group Object "Value 2: Color"color#000000
Value of Group Object "Value 2: HVAC mode"listAutomatic
Value of Group Object "Value 2: 1 byte"unsignedInt 0…2550
Value of Group Object "Value 2: 1 byte signed"signedInt -128…1270
Value of Group Object "Value 2: 2 bytes"unsignedInt 0…655350
Value of Group Object "Value 2: 2 bytes signed"signedInt -32768…327670
Value of Group Object "Value 2: 4 bytes"unsignedInt 0…42949672950
Value of Group Object "Value 4: Percent"unsignedInt 0…1000
Value of Group Object "Value 4: Percent"unsignedInt 0…2550
Value of Group Object "Value 4: Forced operation"listNo forced operation
Value of Group Object "Value 4: Temperature"signedInt -100…25020
Value of Group Object "Value 4: Temperature"signedInt -32768…327672000
Value of Group Object "Value 4: Color"color#000000
Value of Group Object "Value 4: HVAC mode"listAutomatic
Value of Group Object "Value 4: 1 byte"unsignedInt 0…2550
Value of Group Object "Value 4: 1 byte signed"signedInt -128…1270
Value of Group Object "Value 4: 2 bytes"unsignedInt 0…655350
Value of Group Object "Value 4: 2 bytes signed"signedInt -32768…327670
Value of Group Object "Value 4: 4 bytes"unsignedInt 0…42949672950
There is text in the "Default value" columnlist3-fold operation
On 3-fold operation: DPTlistDeactivated
Value of Group Object "Value 3: Switch"listOff
Long operationlistLong operation
On long operation: DPTlistDeactivated
Value of Group Object "Value 4: Switch"listOn
Activate minimum signal durationunsignedInt 0…10
On opening the contacttime1000
On closing the contacttime1000
Input buttonlistSwitching reaction
ApplicationlistFault indicator/logic Input template
Send value of Group Object "Status Fault"listOn change
Sending cycletime30
On Group Object valuelist0 or 1
Send "Status Fault" after ETS download or KNX voltage recoveryunsignedInt 0…10
Input buttonlistBlocked
ApplicationlistSwitching sequence template
Parameter SizeunsignedInt 0…65535131
App_2ButtonunsignedInt 0…10
FunctionlistSwitch
FunctionlistDeactivated
enable 0unsignedInt 0…11
EnableunsignedInt 0…11
GO 1listOff
GO 1unsignedInt 0…1000
GO 1unsignedInt 0…2550
GO 1unsignedInt 0…2551
GO 1unsignedInt 1…641
GO 1color#000000
GO 1listAutomatic
GO 2listOff
GO 2unsignedInt 0…1000
GO 2unsignedInt 0…2550
GO 2unsignedInt 0…2551
GO 2unsignedInt 1…641
GO 2color#000000
GO 2listAutomatic
GO 3listOff
GO 3unsignedInt 0…1000
GO 3unsignedInt 0…2550
GO 3unsignedInt 0…2551
GO 3unsignedInt 1…641
GO 3color#000000
GO 3listAutomatic
GO 4listOff
GO 4unsignedInt 0…1000
GO 4unsignedInt 0…2550
GO 4unsignedInt 0…2551
GO 4unsignedInt 1…641
GO 4color#000000
GO 4listAutomatic
GO 5listOff
GO 5unsignedInt 0…1000
GO 5unsignedInt 0…2550
GO 5unsignedInt 0…2551
GO 5unsignedInt 1…641
GO 5color#000000
GO 5listAutomatic
EnableunsignedInt 0…10
Reaction on long operationlistCorresponds to a short operation
Reaction after last steplistStep 1
Behavior after last steplistNo reaction
Reaction on short operationlistNext step
Reaction on short operationlistPrevious step
Send values after evaluation periodunsignedInt 0…10
Evaluation periodtime2000
Evaluation periodunsignedInt 0…655352000
Enable Group Object "Reset switching sequence"unsignedInt 0…10
App_2ButtonunsignedInt 0…11
ApplicationlistPulse counter template
Parameter SizeunsignedInt 0…6553565
Counter typelist4 bytes unsigned [DPT 12.001]
Generate input pulselistOn closing
Enable Counter 1unsignedInt 0…11
Enable pulse counter 2unsignedInt 0…10
FunctionCodelist
Minimum signal durationunsignedInt 20…10030
Signal typelistDC
Send value of Group Object "Counter value 1"listOn change
Sending cycletime86400
Value is sent from a change ofunsignedInt 1…10000100
Counter-specific settingsunsignedInt 0…10
Start valuesignedInt -128…1270
Initial valuesignedInt -128…1270
Start valueunsignedInt 0…2550
Initial valueunsignedInt 0…2550
Start valuesignedInt -32768…327670
Initial valuesignedInt -32768…327670
Start valueunsignedInt 0…655350
Initial valueunsignedInt 0…655350
Start valuesignedInt -2147483648…21474836470
Initial valuesignedInt -2147483648…21474836470
Start valueunsignedInt 0…42949672950
Initial valueunsignedInt 0…42949672950
Number of input pulses for one counter stepunsignedInt 1…100001
Number of input pulses per counting pulseunsignedInt 1…100001
Change of counter per counter stepsignedInt -10000…100001
Counter reading change per counting pulsesignedInt -10000…100001
Evaluate limit valueunsignedInt 0…10
Limit valuesignedInt -128…127100
Limit valueunsignedInt 0…255100
Limit valuesignedInt -32768…32767100
Limit valueunsignedInt 0…65535100
Limit valuesignedInt -2147483648…2147483647100
Limit valueunsignedInt 0…4294967295100
Reaction on reaching limit valuelistReset to initial value
Send value of Group Object "Counter value 2"listOn change
ApplicationlistSwitch
CHANNEL_MP_CTunsignedInt 0…42949672950
Parameter settingunsignedInt 0…11
BinaryInput_1_TextVirtualtextInput a
BinaryInput_1_StextInput a
BinaryInput_1_DtextInput a+b
ConfigunsignedInt 0…167772150
Input atext
BinaryInput_3_TextVirtualtextInput c
BinaryInput_3_StextInput c
BinaryInput_3_DtextInput c+d
Input ctext
BinaryInput_5_TextVirtualtextInput e
BinaryInput_5_StextInput e
BinaryInput_5_DtextInput e+f
Input etext
BinaryInput_7_TextVirtualtextInput g
BinaryInput_7_StextInput g
BinaryInput_7_DtextInput g+h
Input gtext
BinaryInput_9_TextVirtualtextInput i
BinaryInput_9_StextInput i
BinaryInput_9_DtextInput i+j
Input itext

Application program: Binary Input 10f 20/2.0 2.0

Application number$A0E7
Version2.0
Mask versionMV-07B0 (System B)
KNX Data SecureNo
Minimum ETS version5.0
Parameters0
Group objects0
Group objects (0)
NoNameFunctionSizeDPTFlags
Parameters (0)
ParameterTypeDefault

Version history

ApplicationApp noFingerprintFirst seenSizeFile
Binary Input 10f 20/1.0 1.0 latest$A0E76B762026-11-251.6 MBDownload

About this file

This is the official ETS product database for the ABB AG - STOTZ-KONTAKT BE/S10.20.3.2 Binary Input, 10-fold, Contact Scanning, MDRC (2CDG 110 277 R0011), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.