| Hardware_Type | list | HW |
| Device function | list | Standalone |
| Sending and switching delay after bus voltage recovery | unsignedInt 2…255 | 2 |
| Value after sending and switching delay has expired | list | Last value received |
| Limit number of telegrams | list | No |
| Enable group object
"In operation" | list | No |
| Send value of group object
"In operation" | list | Value 1 |
| In period | list | 1 s |
| Maximum number of telegrams | unsignedInt 1…50 | 20 |
| i-bus Tool access | list | Full access |
| Sending cycle | time | 60 |
| Generator activation after
ETS download | list | Unchanged |
| Status after ETS download | list | Selection |
| Monitor receipt of group object
"Setpoint temperature" | list | Deactivated |
| Monitor receipt of group object
"Setpoint power" | list | Deactivated |
| Cyclical monitoring | list | Deactivated |
| Setpoint generator signal | unsignedInt 0…100 | 50 |
| Setpoint generator signal | signedInt -50…50 | 0 |
| Forced operation | list | Deactivated |
| Time interval for cyclical monitoring | time | 300 |
| Temperature input | list | Deactivated |
| Temperature offset | float -10…10 | 0 |
| Cable length, single distance | float 1…100 | 10 |
| Cross-section of conductor
Value* 0.01 mm² | unsignedInt 1…150 | 100 |
| Value is sent from a change
of | float 0.2…10 | 1 |
| Send cyclically every | time | 30 |
| Resistance in ohms at +120°C | unsignedInt 650…4600 | 3607 |
| Cable resistance
(total of fwd and rtn conductor) | unsignedInt 0…10000 | 500 |
| Object value request on restart and bus voltage recovery | list | No |
| Send temperature value | list | After change |
| NTC type | list | NTC 10-01 [-15...+100 °C] |
| Filter | list | Inactive |
| Cable error compensation | list | None |
| Temperature sensor type | list | PT1000 [-30...+110 °C] |
| KTY type | list | KT 100/110/130 |
| Resistance in ohms at +40°C | unsignedInt 650…4600 | 2080 |
| Resistance in ohms at 0°C | unsignedInt 650…4600 | 1495 |
| Resistance in ohms at +20°C | unsignedInt 650…4600 | 1772 |
| Resistance in ohms at +60°C | unsignedInt 650…4600 | 2417 |
| Resistance in ohms at +80°C | unsignedInt 650…4600 | 2785 |
| Resistance in ohms at +100°C | unsignedInt 650…4600 | 3182 |
| Reaction on event 1 | list | On |
| GP_CD_A0B1011F | text | |
| Convertible from version 0.1 | unsignedInt 0…255 | 1 |
| Switch on pump when control value greater than | unsignedInt 0…99 | 1 |
| Switch off pump when control value less than
(0% = deactivated) | unsignedInt 0…100 | 1 |
| Switch-off delay | time | 5 |
| Send status values | list | After change or on request |
| Send cyclically every | time | 60 |
| Enable manual pump override | list | No |
| Pump reaction on bus voltage failure | list | Unchanged |
| Pump reaction after bus voltage recovery | list | Follows generator activation |
| Pump reaction after bus voltage recovery | list | Unchanged |
| Monitor receipt of group object
"Pump fault" | list | Deactivated |
| Monitor receipt of group object
"Pump repair switch" | list | Deactivated |
| Generator activation after bus voltage recovery | list | As before bus voltage failure |
| On group object value | list | 0 or 1 |
| Setpoint generator signal | unsignedInt 0…100 | 15 |
| Resistance in ohms at -20°C | unsignedInt 650…4600 | 1247 |
| Pump reaction on forced operation | list | On |
| Pump reaction during
forced operation active "ON" | list | On |
| Pump reaction during
forced operation active "OFF" | list | Off |
| When closing the contact | float 0…100 | 1 |
| When opening the contact | float 0…100 | 1 |
| Long operation after | float 1…10 | 1 |
| Relay output | list | Activated |
| Reaction of output | list | NO contact |
| Value of group object "Status Relay" | list | 1: closed, 0: open |
| Send cyclically every | time | 300 |
| Return from manual pump override
to automatic mode | list | Via group object or automatic |
| Monitor pump repair switch | list | Deactivated |
| Monitor pump error | list | Deactivated |
| Monitor pump status | list | Deactivated |
| Reset time | time | 300 |
| Type of generator activation | list | Absolute temperature |
| Signal output (voltage to temperature/power) | list | Normal |
| Max. output voltage for generator Off
Min. output voltage for generator activation | float 0…10 | 5 |
| Max. output voltage for generator activation | float 0…10 | 10 |
| Monitor generator error | list | Deactivated |
| Monitor generator status | list | Deactivated |
| Use generator relay output for generator activation | list | No |
| Min. output voltage generator fault | float 0…10 | 0 |
| Max. output voltage generator fault | float 0…10 | 2 |
| Min. output voltage generator Off | float 0…10 | 2.1 |
| Pump reaction after ETS download | list | Follows generator activation |
| Pump reaction after ETS download | list | Unchanged |
| Enable manual generator override | list | No |
| Return from manual
generator override to automatic mode | list | Via group object or automatic |
| Switch on pump when generator is in activation range | list | Yes |
| Monitor receipt of group object
"Generator fault" | list | Deactivated |
| Generator reaction
during forced operation | list | On |
| Generator reaction
during forced operation active "ON" | list | On |
| Generator reaction
during forced operation active "OFF" | list | On |
| Switching reaction of generator relay
on bus voltage failure | list | Unchanged |
| Setpoint generator signal
during forced operation | signedInt -50…50 | 0 |
| Setpoint generator signal
during forced operation active "ON" | signedInt -50…50 | 0 |
| Setpoint generator signal
during forced operation | unsignedInt 0…100 | 50 |
| Setpoint generator signal
during forced operation active "ON" | unsignedInt 0…100 | 50 |
| Setpoint generator signal
during forced operation active "OFF" | unsignedInt 0…100 | 50 |
| Setpoint generator signal
during forced operation active "OFF" | signedInt -50…50 | 0 |
| Temperature offset on exceeding the
monitoring time | signedInt -50…50 | 0 |
| Setpoint temperature on exceeding the
monitoring time | unsignedInt 0…100 | 50 |
| Setpoint power on exceeding the
monitoring time | unsignedInt 0…100 | 50 |
| Setpoint temperature on exceeding the
monitoring time | unsignedInt 0…100 | 15 |
| Setpoint power on exceeding the
monitoring time | unsignedInt 0…100 | 15 |
| Input | list | Pump status input |
| Input | list | Deactivated |
| Scan input after download, ETS reset or bus voltage recovery | list | Yes |
| Active detected if | list | Contact closed |
| Send status values | list | After change |
| Enable group object
"Block input" | list | No |
| Input on operation | list | Closed |
| Activate minimum signal duration | list | No |
| Distinction between long and short operation | list | No |
| Reaction on event 0 | list | Off |
| Input | list | Pump error input |
| Input | list | Pump repair status input |
| Input | list | Generator status input |
| Input | list | Generator error input |
| Lower temperature limit for generator activation | float 0…100 | 25 |
| Max. temperature decrease for generator activation | float -50…50 | -10 |
| Min. power specified for generator activation | float 0…99 | 1 |
| Max. temperature increase for generator activation | float -50…50 | 10 |
| Upper temperature limit for generator activation | float 0…100 | 60 |
| Max. power specified for generator activation | float 1…100 | 100 |
| Switching reaction of generator relay
after bus voltage recovery | list | Unchanged |
| Switching reaction of generator relay
after ETS download | list | Unchanged |
| Generator reaction after
bus voltage recovery | list | On |
| Generator reaction after
ETS download | list | On |
| Switching reaction of generator relay
during forced operation | list | Unchanged |
| Switching reaction of generator relay
during forced operation active "ON" | list | Unchanged |
| Switching reaction of generator relay
during forced operation active "OFF" | list | Unchanged |