ABB AG - STOTZ-KONTAKT 2CDG 110 209 R0011 FCC/S1.4.1.1 Fan Coil Controller,PWM,3-speed,2-pipe,MDRC

FCC/S1.4.1.1 Fan Coil Controller,PWM,3-speed,2-pipe,MDRC 2CDG 110 209 R0011

ABB AG - STOTZ-KONTAKT · Order number 2CDG 110 209 R0011 · Heating, Ventilation and Air Conditioning › Fan Coil Controllers

Fan Coil Controller, PWM, 3-speed, 2-pipe/1.3

Download .knxprod Fan Coil Controller, PWM, 3-speed, 2-pipe/1.3 1.3 · 324 KB

Product

ManufacturerABB AG - STOTZ-KONTAKT
Product nameFCC/S1.4.1.1 Fan Coil Controller,PWM,3-speed,2-pipe,MDRC
Order number2CDG 110 209 R0011
HardwareFCC/S1.4.1.1 Fan Coil Controller,PWM,3-stufig,2-Rohr,REG
MediumTwisted Pair
Bus current (mA)10
Rail mountedYes
Width (mm)70
RegistrationCertified · 2021-11-17
Languagesen-US, de-DE, es-ES, fr-FR, it-IT, nl-NL, pl-PL, ru-RU
Catalog entryM-0002_H-2CDG.20110.20209.20R0011-2_HP-A0B6-13-A8F0_CI-2CDG.20110.20209.20R0011-1
FingerprintA8F0
SHA-256d4194148e2dea85afc45f9c22ce4bef722e2021e4565c3acaa56aa65870630af
First seen2026-11-25
Markets59 markets

Application program: Fan Coil Controller, PWM, 3-speed, 2-pipe/1.3 1.3

Application number$A0B6
Version1.3
Mask versionMV-07B0 (System B)
KNX Data SecureNo
Minimum ETS version5.0
Parameters409
Group objects134
Group objects (134)
NoNameFunctionSizeDPTFlags
1GeneralIn operation1 Bit1.2 booleanCRT
2GeneralStatus byte Device1 ByteCRT
3GeneralRequest status values1 Bit1.17 triggerCW
10Channel - GeneralForced operation, 2-bit2 Bit2.1 switch controlCW
11Channel - GeneralForced operation, 1-bit1 Bit1.2 booleanCW
12Channel - GeneralError "Heating/cooling changeover" receipt1 Bit1.5 alarmCRT
13Channel - GeneralError "Window status" receipt1 Bit1.5 alarmCRT
14Channel - GeneralError "Dew point status" receipt1 Bit1.5 alarmCRT
15Channel - GeneralError "Fill level status" receipt1 Bit1.5 alarmCRT
16Channel - GeneralError "Operating mode" receipt1 Bit1.5 alarmCRT
16Channel - GeneralError "Control value" receipt1 Bit1.5 alarmCRT
18Channel - FanStatus Fan On/Off1 Bit1.1 switchCRT
19Channel - FanStatus byte Fan1 ByteCRT
20Channel - FanStatus Fan automatic1 Bit1.11 stateCRT
21Channel - FanStatus Fan speed1 Byte5.1 percentage (0..100%)CRT
21Channel - FanStatus Fan speed1 Byte5.10 counter pulses (0..255)CRT
22Channel - FanStatus Fan speed 11 Bit1.1 switchCRT
23Channel - FanStatus Fan speed 21 Bit1.1 switchCRT
24Channel - FanStatus Fan speed 31 Bit1.1 switchCRT
25Channel - FanActivate/deactivate fan automatic1 Bit1.3 enableCW
26Channel - FanSwitch fan speed 11 Bit1.1 switchCW
27Channel - FanSwitch fan speed 21 Bit1.1 switchCW
28Channel - FanSwitch fan speed 31 Bit1.1 switchCW
29Channel - FanSwitch fan speed1 Byte5.1 percentage (0..100%)CW
30Channel - FanIncrease/decrease fan speed1 Bit1.7 stepCW
31Channel - FanLimitation 11 Bit1.3 enableCW
32Channel - FanLimitation 21 Bit1.3 enableCW
33Channel - FanLimitation 31 Bit1.3 enableCW
35Channel - Valve AStatus byte valve A1 ByteCRT
36Channel - Valve AStatus Control value valve A1 Byte5.1 percentage (0..100%)CRT
37Channel - Valve AFault Valve output A1 Bit1.5 alarmCRT
38Channel - Valve AStatus Valve purge A1 Bit1.11 stateCRT
39Channel - Valve AReset fault Valve output A1 Bit1.15 resetCW
40Channel - Valve AActivate valve purge A1 Bit1.17 triggerCW
41Channel - Valve AEnable/block manual valve override A1 Bit1.3 enableCW
42Channel - Valve AOverride valve control value A1 Byte5.1 percentage (0..100%)CW
44Channel - Input aTemperature2 Bytes9.1 temperature (°C)CRT
45Channel - Input aError Input1 Bit1.5 alarmCRT
46Channel - Input aContact position binary input1 Bit1.1 switchCRT
46Channel - Input aWindow contact1 Bit1.19 window/doorCRT
46Channel - Input aDew point alarm1 Bit1.5 alarmCRT
46Channel - Input aFill level alarm1 Bit1.5 alarmCRT
47Channel - Input aBlock input1 Bit1.3 enableCW
48Channel - Input bTemperature2 Bytes9.1 temperature (°C)CRT
49Channel - Input bError Input1 Bit1.5 alarmCRT
50Channel - Input bContact position binary input1 Bit1.1 switchCRT
50Channel - Input bWindow contact1 Bit1.19 window/doorCRT
50Channel - Input bDew point alarm1 Bit1.5 alarmCRT
50Channel - Input bFill level alarm1 Bit1.5 alarmCRT
51Channel - Input bBlock input1 Bit1.3 enableCW
52Channel - Input cTemperature2 Bytes9.1 temperature (°C)CRT
53Channel - Input cError Input1 Bit1.5 alarmCRT
54Channel - Input cContact position binary input1 Bit1.1 switchCRT
54Channel - Input cWindow contact1 Bit1.19 window/doorCRT
54Channel - Input cDew point alarm1 Bit1.5 alarmCRT
54Channel - Input cFill level alarm1 Bit1.5 alarmCRT
55Channel - Input cBlock input1 Bit1.3 enableCW
56Channel - Input dTemperature2 Bytes9.1 temperature (°C)CRT
57Channel - Input dError Input1 Bit1.5 alarmCRT
58Channel - Input dContact position binary input1 Bit1.1 switchCRT
58Channel - Input dWindow contact1 Bit1.19 window/doorCRT
58Channel - Input dDew point alarm1 Bit1.5 alarmCRT
58Channel - Input dFill level alarm1 Bit1.5 alarmCRT
59Channel - Input dBlock input1 Bit1.3 enableCW
60Channel - ControllerStatus Heating/cooling1 Bit1.100 cooling/heatingCRT
61Channel - ControllerStatus Control value basic-stage heating1 Byte5.1 percentage (0..100%)CRT
61Channel - ControllerStatus Control value basic-stage heating1 Bit1.1 switchCRT
62Channel - ControllerStatus Control value additional-stage heating1 Byte5.1 percentage (0..100%)CRT
62Channel - ControllerStatus Control value additional-stage heating1 Bit1.1 switchCRT
63Channel - ControllerStatus Control value basic-stage cooling1 Byte5.1 percentage (0..100%)CRT
63Channel - ControllerStatus Control value basic-stage cooling1 Bit1.1 switchCRT
64Channel - ControllerStatus Control value additional-stage cooling1 Byte5.1 percentage (0..100%)CRT
64Channel - ControllerStatus Control value additional-stage cooling1 Bit1.1 switchCRT
66Channel - ControllerActual temperature2 Bytes9.1 temperature (°C)CRT
67Channel - ControllerExternal temperature 12 Bytes9.1 temperature (°C)CWTU
68Channel - ControllerExternal temperature 22 Bytes9.1 temperature (°C)CWTU
69Channel - ControllerFault Actual temperature (master)1 Bit1.5 alarmCRT
70Channel - ControllerCurrent setpoint2 Bytes9.1 temperature (°C)CRT
71Channel - ControllerOperating mode Normal (master)1 Byte20.102 HVAC modeCWTU
72Channel - ControllerOperating mode override (master)1 Byte20.102 HVAC modeCWTU
73Channel - ControllerWindow contact (master/slave)1 Bit1.19 window/doorCW
74Channel - ControllerPresence detector (master/slave)1 Bit1.18 occupancyCW
75Channel - ControllerStatus Heating1 Bit1.1 switchCRT
76Channel - ControllerStatus Cooling1 Bit1.1 switchCRT
77Channel - ControllerActivation of minimum control value (basic load)1 Bit1.3 enableCW
78Channel - ControllerHeating/cooling changeover1 Bit1.100 cooling/heatingCWTU
78Channel - ActuatorHeating/cooling changeover1 Bit1.100 cooling/heatingCWTU
79Channel - ControllerBasic setpoint2 Bytes9.1 temperature (°C)CW
80Channel - ControllerReset manual setpoint adjustment1 Bit1.17 triggerCW
81Channel - ControllerDew point alarm1 Bit1.5 alarmCWTU
82Channel - ControllerFill level alarm1 Bit1.5 alarmCWTU
83Channel - ControllerOutside temperature for summer compensation2 Bytes9.1 temperature (°C)CW
84Channel - ControllerSummer compensation active/inactive1 Bit1.2 booleanCRT
85Channel - ControllerComfort setpoint reached1 Bit1.2 booleanCRT
86Channel - ControllerRequest On/Off (master)1 Bit1.1 switchCW
87Channel - ControllerConfirm On/Off (master)1 Bit1.1 switchCRT
88Channel - ControllerSetpoint display (master)2 Bytes9.1 temperature (°C)CRT
89Channel - ControllerRequest setpoint adjustment (master)2 Bytes9.1 temperature (°C)CW
89Channel - ControllerRequest setpoint adjustment (master)2 Bytes9.2 temperature difference (K)CW
89Channel - ControllerRequest setpoint adjustment (master)1 Byte6.10 counter pulses (-128..127)CW
89Channel - ActuatorRequest setpoint adjustment (slave)2 Bytes9.2 temperature difference (K)CRT
89Channel - ActuatorRequest setpoint adjustment (slave)1 Byte6.10 counter pulses (-128..127)CRT
90Channel - ControllerConfirm setpoint adjustment (master)2 Bytes9.1 temperature (°C)CRT
90Channel - ControllerConfirm setpoint adjustment (master)2 Bytes9.2 temperature difference (K)CRT
90Channel - ControllerConfirm setpoint adjustment (master)1 Byte6.10 counter pulses (-128..127)CRT
91Channel - ControllerRequest heating/cooling (master)1 Bit1.100 cooling/heatingCW
92Channel - ControllerRequest fan manually (master)1 Bit1.1 switchCW
92Channel - ActuatorRequest fan manually (slave)1 Bit1.1 switchCRT
93Channel - ControllerConfirm fan manually (master)1 Bit1.1 switchCRT
93Channel - ActuatorConfirm fan manually (slave)1 Bit1.1 switchCW
94Channel - ControllerRequest fan speed (master)1 Byte5.10 counter pulses (0..255)CW
94Channel - ControllerRequest fan speed (master)1 Byte5.1 percentage (0..100%)CW
94Channel - ActuatorRequest fan speed (slave)1 Byte5.10 counter pulses (0..255)CRT
94Channel - ActuatorRequest fan speed (slave)1 Byte5.1 percentage (0..100%)CRT
95Channel - ControllerConfirm fan speed (master)1 Byte5.10 counter pulses (0..255)CRT
95Channel - ControllerConfirm fan speed (master)1 Byte5.1 percentage (0..100%)CRT
96Channel - ControllerStatus Controller RHCC2 Bytes22.101 RHCC statusCRT
97Channel - ControllerStatus Controller HVAC (master)1 Byte5.1 percentage (0..100%)CRT
98Channel - ControllerCurrent HVAC operating mode1 Byte20.102 HVAC modeCRT
99Channel - ControllerComfort heating setpoint2 Bytes9.1 temperature (°C)CW
99Channel - ControllerComfort heating/cooling setpoint2 Bytes9.1 temperature (°C)CW
100Channel - ControllerComfort cooling setpoint2 Bytes9.1 temperature (°C)CW
101Channel - ControllerEconomy heating setpoint2 Bytes9.1 temperature (°C)CW
102Channel - ControllerEconomy cooling setpoint2 Bytes9.1 temperature (°C)CW
103Channel - ControllerStandby heating setpoint2 Bytes9.1 temperature (°C)CW
104Channel - ControllerStandby cooling setpoint2 Bytes9.1 temperature (°C)CW
105Channel - ControllerBuilding Protection heating setpoint2 Bytes9.1 temperature (°C)CW
106Channel - ControllerBuilding Protection cooling setpoint2 Bytes9.1 temperature (°C)CW
107Channel - ActuatorHeating control value1 Byte5.1 percentage (0..100%)CWTU
108Channel - ActuatorCooling control value1 Byte5.1 percentage (0..100%)CWTU
109Channel - ControllerBasic-stage heating limit temperature2 Bytes9.1 temperature (°C)CWTU
110Channel - ControllerAdditional-stage heating limit temperature2 Bytes9.1 temperature (°C)CWTU
111Channel - ControllerBasic-stage cooling limit temperature2 Bytes9.1 temperature (°C)CWTU
112Channel - ControllerAdditional-stage cooling limit temperature2 Bytes9.1 temperature (°C)CWTU
Parameters (223)
ParameterTypeDefault
Hardware_TypelistHW
Device functionlistStandalone
Sending and switching delay after bus voltage recoveryunsignedInt 2…2552
Value after sending and switching delay has expiredlistLast value received
Limit number of telegramslistNo
Enable Group Object "In operation"listNo
Send value of Group Object "In operation"listValue 1
In periodlist1 s
Maximum number of sent telegramsunsignedInt 1…5020
i-bus® Tool accesslistFull access
Sending cycletime60
Device functionlistController
Window status receiptlistDeactivated
Window open whenlistValue 1
Dew point status receiptlistDeactivated
Dew point reached whenlistValue 1
Fill level status receiptlistDeactivated
Fill level reached whenlistValue 1
Actual temperature receiptlistVia physical device input
Number of Group Objects Actual temperaturelist1
Internal measurement weightingunsignedInt 0…100100
Weighting of external measurement 2unsignedInt 0…10050
Operating mode after bus voltage recoverylistAs before bus voltage failure
Control value after bus voltage recoverylistAs before bus voltage failure
Control value after ETS downloadlistUnchanged
Status after ETS download/resetlistUnchanged
Limitation of fan speedlistDeactivated
Cyclical monitoringlistDeactivated
Monitor receipt of Group Object "Operating mode Normal (master)"listDeactivated
Monitor receipt of Group Objects "Heating/cooling control value"listDeactivated
Monitor receipt of Group Object "Heating/cooling changeover"listDeactivated
Monitor receipt of Group Object "Window contact"listDeactivated
Monitor receipt of Group Object "Dew point alarm"listDeactivated
Monitor receipt of Group Object "Fill level alarm"listDeactivated
Forced operationlistDeactivated
Control value on forced operationunsignedInt 0…1000
Control value during forced operation active "ON"unsignedInt 0…1000
Control value during forced operation active "OFF"unsignedInt 0…1000
Temperature input monitoringlistDeactivated
Time interval for cyclical monitoringtime300
Operating mode on exceeding the monitoring timelistUnchanged
Threshold value fan speed 0 <-> 1unsignedInt 0…101
Threshold value fan speed 1 <-> 2unsignedInt 1…10030
Threshold value fan speed 2 <-> 3unsignedInt 1…10070
Threshold values hysteresisunsignedInt 0…205
Delay between fan speed switchoverunsignedInt 50…5000500
Minimum dwell time at fan speedunsignedInt 0…6005
Number of fan speedslist3
Fan operating modelistChangeover switch
Enable automatic mode based on control valuelistYes
Return from manual fan adjustment to automatic modelistVia Group Object
Start-up behaviorlistNo
Run-on reactionlistNo
Minimum dwell time at switch-on speedunsignedInt 0…6005
Run-on speed 1unsignedInt 0…60020
Run-on speed 2unsignedInt 0…60020
Run-on speed 3unsignedInt 0…60020
Reset timetime3600
Resistance in ohms at +120 °CunsignedInt 650…46003607
Temperature offsetfloat -10…100
Cable length, single distancefloat 1…10010
Cross-section of conductor Value* 0.01 mm²unsignedInt 1…150100
Cable resistance (total of fwd and rtn conductor)unsignedInt 0…10000500
Value is sent from a change offloat 0.2…101
Send cyclically everytime30
InputlistDeactivated
Minimum control value for basic load > 0listAlways active
Setpoint temperature offset when summer compensation startsfloat 0…12.70
Setpoint temperature offset when summer compensation endsfloat 0…12.76
Type of control value Basic-stage heatinglistPI continuous (0...100%)
Control value directionlistNormal
Extended settingslistNo
Control value difference for sending control valuelist5 %
I-proportionunsignedInt 0…255100
Send control value cyclically (0 = deactivated)unsignedInt 0…6015
P-proportionfloat 1…101.5
Hysteresisfloat 0.3…25.50.5
Maximum control valueunsignedInt 1…100100
Minimum control value (basic load)unsignedInt 0…1000
Type of control value Additional-stage heatinglistPI continuous (0...100%)
Temperature difference from basic-stage heatingfloat 0…25.52
Type of control value Basic-stage coolinglistPI continuous (0...100%)
P-proportionfloat 1…102
Type of control value Additional-stage coolinglistPI continuous (0...100%)
Economy cooling increaseunsignedInt 0…154
Economy cooling setpointunsignedInt 10…4029
Comfort heating and cooling setpointunsignedInt 10…4021
Comfort heating setpointunsignedInt 10…4021
Standby heating reductionunsignedInt 0…152
Economy heating reductionunsignedInt 0…154
Standby cooling increaseunsignedInt 0…152
Standby heating setpointunsignedInt 10…4019
Economy heating setpointunsignedInt 10…4017
Standby cooling setpointunsignedInt 10…4027
Setpoint for frost protection (Building Protection heating)unsignedInt 5…157
Setpoint for heat protection (Building Protection cooling)unsignedInt 27…4535
Cycle for sending the setpointunsignedInt 5…24015
Max. manual increase in heating mode via KNXunsignedInt 0…93
Max. manual reduction in heating mode via KNXunsignedInt 0…93
Max. manual increase in cooling mode via KNXunsignedInt 0…93
Max. manual reduction in cooling mode via KNXunsignedInt 0…93
Operating modeslistComfort, Standby, Economy, Building Protection
Comfort heating setpoint = Comfort cooling setpointlistNo
Setpoint specification and adjustmentlistRelative
Send current setpointlistOn change
Base setpoint islistComfort heating setpoint
Reset manual setpoint adjustment via KNX when base setpoint receivedlistYes
Reset manual setpoint adjustment via KNX when operating mode changeslistYes
Reset manual setpoint adjustment via KNX using Group ObjectlistYes
Temperature difference from basic-stage coolingfloat 0…25.52
Activate summer compensationlistNo
Starting temperature for summer compensationsignedInt 10…5021
Ending temperature for summer compensationsignedInt 10…5032
Control value on exceeding the monitoring timeunsignedInt 0…10025
Control value on input faultunsignedInt 0…10025
Send status valueslistOn change or on request
Send cyclically everytime300
Object value request on restart and bus voltage recoverylistNo
Additional-stage heatinglistDeactivated
Additional-stage coolinglistDeactivated
Type of heating/cooling systemlist4-pipe
Setpoint indication on slave displaylistAbsolute
Hysteresis for Heating/cooling changeoverfloat 0.5…102
Heating/cooling changeoverlistAutomatic
Valve purgelistAutomatic or via Group Object
Valve outputlistThermoelectric (PWM)
Open if control value greater than or equal tounsignedInt 1…1001
Valve drive operating principle, de-energizedlistClosed
PWM cycle timeunsignedInt 10…900180
Valve drive opening/closing timeunsignedInt 10…900180
Purge cycle in weeksunsignedInt 1…124
Reset purge cycle from control value greater than or equal tounsignedInt 1…9999
Send value of Group Object "Status Valve purge"listNo, update only
Convertible from version 0.1unsignedInt 0…2551
Send temperature valuelistOn change
Resistance in ohms at +100 °CunsignedInt 650…46003182
Heating PWM cycleunsignedInt 1…6015
Cooling PWM cycleunsignedInt 1…6015
Activate temperature limitationlistNo
I-proportion at temperature limitationlistFreeze
Limit temperatureunsignedInt 20…5030
Input for temperature limit sensorlistVia Group Object
Limit temperature hysteresisfloat 0.5…51
Limit temperatureunsignedInt 1…3010
Use control value for fan automaticlistYes
Use control value for fan automaticlistNo
Switch fan speed via 1-bit Group ObjectslistDeactivated
Enable manual valve overridelistNo
GP_CD_A0B6011Ftext
Operating mode after ETS download/resetlistHeating
Cycle for sending the room temperature (0 = deactivated)unsignedInt 0…25515
Temperature change for sending current room temperaturefloat 0.1…100.5
Data point type, manual setpoint adjustmentlistDPT 9.001 (absolute temperature value)
Data point type, manual setpoint adjustmentlistDPT 9.002 (relative temperature value)
Data point type, manual fan adjustmentlistDPT 5.001 (percentage value)
Send inactive control values cyclicallylistNo
Comfort cooling setpointunsignedInt 10…4025
Fan behavior on bus voltage failurelistUnchanged
Fan speed after ETS downloadlistUnchanged
Basic load active when controller offlistNo
Weighting of external measurement 1unsignedInt 0…10050
Basic-stage heatinglistFan coil unit: Water heating coil
Basic-stage heatinglistFan coil unit
Basic-stage coolinglistFan coil unit
Basic-stage coolinglistFan coil unit: Water cooling coil
Activate additional-stage cooling vialistGroup Object
Activate additional-stage cooling vialistInternal output A (valve)
Activate additional-stage heating vialistGroup Object
Activate additional-stage heating vialistInternal output A (valve)
Activate basic-stage cooling vialistInternal output A (valve)
Activate basic-stage cooling vialistGroup Object
Activate basic-stage heating vialistInternal output A (valve)
Activate basic-stage heating vialistGroup Object
Fan speed after bus voltage recoverylistUnchanged
Control valueunsignedInt 0…1000
Fan speed during forced operationlistUnchanged
Fan speed during forced operation active "ON"listUnchanged
Fan speed during forced operation active "OFF"listUnchanged
Operating mode on exceeding the monitoring timelistBuilding Protection
Switch on at fan speedlist3
Switch on at fan speedlist2
Limitation 1listOff, 1, 2, 3
Limitation 1listOff, 1, 2
Limitation 1listOff, 1
Limitation 2listOff, 1
Limitation 2listOff, 1, 2, 3
Limitation 2listOff, 1, 2
Limitation 3listOff, 1, 2, 3
Limitation 3listOff, 1, 2
Limitation 3listOff, 1
InputlistAnalog room control unit
Scan input after download, ETS reset or bus voltage recoverylistYes
Maximum setpoint increaseunsignedInt 0…53
Window open whenlistContact open
Dew point reached whenlistContact open
Fill level reached whenlistContact open
Send status valueslistOn change
Cable error compensationlistNone
Enable Group Object "Block input"listNo
Input on operationlistClosed
Temperature sensor typelistPT1000 [-30...+110 C]
Activate minimum signal durationlistNo
Distinction between long and short operationlistNo
On Group Object valuelist0 or 1
KTY typelistKT 100/110/130
Maximum setpoint reductionunsignedInt 0…53
Reaction on event 1listOn
Reaction on event 0listOff
NTC typelistNTC 10-01 [-15...+100 °C]
FilterlistInactive
Resistance in ohms at -20 °CunsignedInt 650…46001247
When closing the contactfloat 0…1001
Connect analog room control unit to physical device inputlistNo
Resistance in ohms at 0 °CunsignedInt 650…46001495
Resistance in ohms at +20 °CunsignedInt 650…46001772
When opening the contactfloat 0…1001
Resistance in ohms at +40 °CunsignedInt 650…46002080
Resistance in ohms at +60 °CunsignedInt 650…46002417
Long operation afterfloat 1…101
Resistance in ohms at +80 °CunsignedInt 650…46002785
Operating mode after bus voltage recovery or ETS downloadlistComfort
Send value of Group Object "Activate/deactivate fan automatic"list1: activate, 0: deactivate
Data point type, Group Object "Status Fan speed"listDPT 5.001 (percentage value)

Version history

ApplicationApp noFingerprintFirst seenSizeFile
Fan Coil Controller, PWM, 3-speed, 2-pipe/1.3 1.3 latest$A0B6A8F02026-11-25324 KBDownload

About this file

This is the official ETS product database for the ABB AG - STOTZ-KONTAKT FCC/S1.4.1.1 Fan Coil Controller,PWM,3-speed,2-pipe,MDRC (2CDG 110 209 R0011), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.

More from ABB AG - STOTZ-KONTAKT

All ABB AG - STOTZ-KONTAKT products