EM/S3.16.1 Energy Module,3F,16/20A,MDRC 2CDG 110 148 R0011
ABB AG - STOTZ-KONTAKT · Order number 2CDG 110 148 R0011 · Energy Management › Energy Modules and Actuators
Download .knxprod Measure 3f/1.0b 1.0 · 596 KB
Product
| Manufacturer | ABB AG - STOTZ-KONTAKT |
|---|---|
| Product name | EM/S3.16.1 Energy Module,3F,16/20A,MDRC |
| Order number | 2CDG 110 148 R0011 |
| Product text | EM/S3.16.1 Energiemodul,3fach,16/20A,REG |
| Hardware | EM/S3.16.1 |
| Medium | Twisted Pair |
| Bus current (mA) | 12 |
| Rail mounted | Yes |
| Registration | Registered |
| Languages | en-US, de-DE |
| Catalog entry | M-0002_H-2CDH110148R0011-2_HP-A07E-10-5EC2_CI-2CDG.20110.20148.20R0011-1 |
| Fingerprint | 5EC2 |
| SHA-256 | 89d380fe758c3cf769c1c3ade21d37ccc7b89b9a0d87f7043a4bcd0457ec0140 |
| First seen | 2026-11-25 |
| Markets | 59 markets |
Application program: Messen 3f/1.0b 1.0
| Application number | $A07E |
|---|---|
| Version | 1.0 |
| Mask version | MV-0701 (7.1) |
| KNX Data Secure | No |
| Parameters | 888 |
| Group objects | 271 |
Group objects (271)
| No | Name | Function | Size | DPT | Flags |
|---|---|---|---|---|---|
| 0 | System | In Betrieb | 1 Bit | 1.2 boolean | CT |
| 1 | Allgemein | Sicherheit Priorität 1 | 1 Bit | CWU | |
| 2 | Allgemein | Sicherheit Priorität 2 | 1 Bit | CWU | |
| 3 | Allgemein | Sicherheit Priorität 3 | 1 Bit | CWU | |
| 4 | Allgemein | Statuswerte anfordern | 1 Bit | CW | |
| 5 | Allgemein | Zählerstände anfordern | 1 Bit | CW | |
| 6 | Allgemein | Instrumentenwerte anfordern | 1 Bit | CW | |
| 7 | Allgemein | Leistungswerte anfordern | 1 Bit | CW | |
| 8 | Allgemein | Uhrzeit empfangen | 3 Bytes | 10.1 time of day | CW |
| 9 | Diagnose | Messelektronik aktiv | 1 Bit | CRT | |
| 10 | Laststeuerung | Abschaltstufe empfangen | 1 Byte | CW | |
| 11 | Zähler | Freig. Rücksetzen Zählerstände | 1 Bit | 1.3 enable | CRW |
| 12 | Zähler | Rücksetzen Zählerstände | 1 Bit | CW | |
| 13 | Laststeuerung Master | Laststeuerung deaktivieren | 1 Bit | 1.3 enable | CRW |
| 14 | Allgemein | Externe Leistungswerte anf. | 1 Bit | CWT | |
| 15 | Laststeuerung Master | Status Laststeuerung | 4 Bytes | CRT | |
| 16 | Laststeuerung Master | Lastgrenze überschritten | 1 Bit | CRT | |
| 17 | Laststeuerung Master | Leistungswert 1 empfangen | 4 Bytes | 14.56 power (W) | CWTU |
| 18 | Laststeuerung Master | Leistungswert 2 empfangen | 4 Bytes | 14.56 power (W) | CWTU |
| 19 | Laststeuerung Master | Leistungswert 3 empfangen | 4 Bytes | 14.56 power (W) | CWTU |
| 20 | Laststeuerung Master | Leistungswert 4 empfangen | 4 Bytes | 14.56 power (W) | CWTU |
| 21 | Laststeuerung Master | Leistungswert 5 empfangen | 4 Bytes | 14.56 power (W) | CWTU |
| 22 | Laststeuerung Master | Leistungswert 6 empfangen | 4 Bytes | 14.56 power (W) | CWTU |
| 23 | Laststeuerung Master | Leistungswert 7 empfangen | 4 Bytes | 14.56 power (W) | CWTU |
| 24 | Laststeuerung Master | Leistungswert 8 empfangen | 4 Bytes | 14.56 power (W) | CWTU |
| 25 | Laststeuerung Master | Leistungswert 9 empfangen | 4 Bytes | 14.56 power (W) | CWTU |
| 26 | Laststeuerung Master | Leistungswert 10 empfangen | 4 Bytes | 14.56 power (W) | CWTU |
| 27 | Laststeuerung Master | Summe Leistungswerte senden | 4 Bytes | 14.56 power (W) | CRT |
| 28 | Laststeuerung Master | Abschaltstufe senden | 1 Byte | CRT | |
| 29 | Laststeuerung Master | Lastgrenze wählen | 1 Byte | 5.10 counter pulses (0..255) | CW |
| 30 | Laststeuerung Master | Lastgrenze senden/empfangen | 4 Bytes | 14.56 power (W) | CRWT |
| 30 | Laststeuerung Master | Lastgrenze senden | 4 Bytes | 14.56 power (W) | CRT |
| 31 | Hauptzähler Gesamt | Zählerstand | 4 Bytes | CRT | |
| 32 | Zwischenzähler Gesamt | Zählerstand | 4 Bytes | CRT | |
| 33 | Zwischenzähler Gesamt | Status | 1 Byte | CRT | |
| 34 | Zwischenzähler Gesamt | Trigger 1 empfangen | 1 Bit | CW | |
| 34 | Zwischenzähler Gesamt | Trigger 1 Zeit ändern | 3 Bytes | 10.1 time of day | CRWT |
| 35 | Zwischenzähler Gesamt | Trigger 2 Dauer ändern | 2 Bytes | CRWT | |
| 35 | Zwischenzähler Gesamt | Trigger 2 Endwert ändern | 4 Bytes | CRWT | |
| 35 | Zwischenzähler Gesamt | Trigger 2 Zeit ändern | 3 Bytes | 10.1 time of day | CRWT |
| 35 | Zwischenzähler Gesamt | Trigger 2 empfangen | 1 Bit | CW | |
| 36 | Zwischenzähler Gesamt | Rücksetzen | 1 Bit | CW | |
| 37 | Wirkleistung Gesamt | Wirkleistung | 4 Bytes | 14.56 power (W) | CRT |
| 38 | Wirkleistung Gesamt | Schwellwert 1 untere Grenze | 4 Bytes | 14.56 power (W) | CRWT |
| 39 | Wirkleistung Gesamt | Schwellwert 1 obere Grenze | 4 Bytes | 14.56 power (W) | CRWT |
| 40 | Wirkleistung Gesamt | Schwellwert 1 Warnung | 1 Bit | CRT | |
| 41 | Wirkleistung Gesamt | Schwellwert 2 untere Grenze | 4 Bytes | 14.56 power (W) | CRWT |
| 42 | Wirkleistung Gesamt | Schwellwert 2 obere Grenze | 4 Bytes | 14.56 power (W) | CRWT |
| 43 | Wirkleistung Gesamt | Schwellwert 2 Warnung | 1 Bit | CRT | |
| 44 | Frequenz | Frequenz | 4 Bytes | 14.33 frequency (Hz) | CRT |
| 45 | Frequenz | Schwellwert 1 untere Grenze | 4 Bytes | 14.33 frequency (Hz) | CRWT |
| 46 | Frequenz | Schwellwert 1 obere Grenze | 4 Bytes | 14.33 frequency (Hz) | CRWT |
| 47 | Frequenz | Schwellwert 1 Warnung | 1 Bit | CRT | |
| 48 | Frequenz | Schwellwert 2 untere Grenze | 4 Bytes | 14.33 frequency (Hz) | CRWT |
| 49 | Frequenz | Schwellwert 2 obere Grenze | 4 Bytes | 14.33 frequency (Hz) | CRWT |
| 50 | Frequenz | Schwellwert 2 Warnung | 1 Bit | CRT | |
| 51 | Diagnose | Frequenzfehler | 1 Bit | CRT | |
| 52 | Dummy | Dummy | 1 Bit | ||
| 53 | Dummy | Dummy | 1 Bit | ||
| 54 | Dummy | Dummy | 1 Bit | ||
| 55 | Dummy | Dummy | 1 Bit | ||
| 56 | Dummy | Dummy | 1 Bit | ||
| 57 | Dummy | Dummy | 1 Bit | ||
| 58 | Dummy | Dummy | 1 Bit | ||
| 59 | Dummy | Dummy | 1 Bit | ||
| 60 | A: Schalten | Schalten | 1 Bit | CW | |
| 61 | A: Schalten | Status Schalten | 1 Bit | CRT | |
| 62 | A: Diagnose | Wirkleistung negativ | 1 Bit | CRT | |
| 63 | A: Zeit | Dauer-EIN | 1 Bit | CW | |
| 64 | A: Zeit | Funktion Zeit sperren | 1 Bit | CRWT | |
| 65 | A: Treppenlicht | Treppenlicht Zeitdauer | 2 Bytes | CRWT | |
| 66 | A: Treppenlicht | Treppenlicht Warnung | 1 Bit | CT | |
| 67 | A: Szene | 8-Bit-Szene | 1 Byte | CW | |
| 68 | A: Logik | Log. Verknüpfung 1 | 1 Bit | CW | |
| 69 | A: Logik | Log. Verknüpfung 2 | 1 Bit | CW | |
| 70 | A: Zwang | Zwangsführung | 1 Bit | CW | |
| 71 | A: Kontakt | Kontaktüberwachung | 1 Bit | CRT | |
| 72 | Dummy | Dummy | 1 Bit | ||
| 73 | Dummy | Dummy | 1 Bit | ||
| 74 | A: Hauptzähler | Zählerstand | 4 Bytes | CRT | |
| 75 | A: Zwischenzähler | Zählerstand | 4 Bytes | CRT | |
| 76 | A: Zwischenzähler | Status | 1 Byte | CRT | |
| 77 | A: Zwischenzähler | Trigger 1 empfangen | 1 Bit | CW | |
| 77 | A: Zwischenzähler | Trigger 1 Zeit ändern | 3 Bytes | 10.1 time of day | CRWT |
| 78 | A: Zwischenzähler | Trigger 2 Dauer ändern | 2 Bytes | CRWT | |
| 78 | A: Zwischenzähler | Trigger 2 Endwert ändern | 4 Bytes | CRWT | |
| 78 | A: Zwischenzähler | Trigger 2 Zeit ändern | 3 Bytes | 10.1 time of day | CRWT |
| 78 | A: Zwischenzähler | Trigger 2 empfangen | 1 Bit | CW | |
| 79 | A: Zwischenzähler | Rücksetzen | 1 Bit | CW | |
| 80 | A: Laststeuerung Slave | Laststeuerung deaktivieren | 1 Bit | 1.3 enable | CRW |
| 81 | A: Laststeuerung Slave | Abschaltstufe Ausgang | 1 Byte | 5.10 counter pulses (0..255) | CRWT |
| 82 | A: Wirkleistung | Wirkleistung | 4 Bytes | 14.56 power (W) | CRT |
| 83 | A: Wirkleistung | Schwellwert 1 untere Grenze | 4 Bytes | 14.56 power (W) | CRWT |
| 84 | A: Wirkleistung | Schwellwert 1 obere Grenze | 4 Bytes | 14.56 power (W) | CRWT |
| 85 | A: Wirkleistung | Schwellwert 1 Warnung | 1 Bit | CRT | |
| 86 | A: Wirkleistung | Schwellwert 2 untere Grenze | 4 Bytes | 14.56 power (W) | CRWT |
| 87 | A: Wirkleistung | Schwellwert 2 obere Grenze | 4 Bytes | 14.56 power (W) | CRWT |
| 88 | A: Wirkleistung | Schwellwert 2 Warnung | 1 Bit | CRT | |
| 89 | A: Strom | Stromwert | 4 Bytes | 14.19 electric current (A) | CRT |
| 90 | A: Strom | Schwellwert 1 untere Grenze | 4 Bytes | 14.19 electric current (A) | CRWT |
| 91 | A: Strom | Schwellwert 1 obere Grenze | 4 Bytes | 14.19 electric current (A) | CRWT |
| 92 | A: Strom | Schwellwert 1 Warnung | 1 Bit | CRT | |
| 93 | A: Strom | Schwellwert 2 untere Grenze | 4 Bytes | 14.19 electric current (A) | CRWT |
| 94 | A: Strom | Schwellwert 2 obere Grenze | 4 Bytes | 14.19 electric current (A) | CRWT |
| 95 | A: Strom | Schwellwert 2 Warnung | 1 Bit | CRT | |
| 96 | A: Spannung | Spannung | 4 Bytes | 14.27 electric potential (V) | CRT |
| 97 | A: Spannung | Schwellwert 1 untere Grenze | 4 Bytes | 14.27 electric potential (V) | CRWT |
| 98 | A: Spannung | Schwellwert 1 obere Grenze | 4 Bytes | 14.27 electric potential (V) | CRWT |
| 99 | A: Spannung | Schwellwert 1 Warnung | 1 Bit | CRT | |
| 100 | A: Spannung | Schwellwert 2 untere Grenze | 4 Bytes | 14.27 electric potential (V) | CRWT |
| 101 | A: Spannung | Schwellwert 2 obere Grenze | 4 Bytes | 14.27 electric potential (V) | CRWT |
| 102 | A: Spannung | Schwellwert 2 Warnung | 1 Bit | CRT | |
| 103 | A: Scheinleistung | Scheinleistung | 4 Bytes | 14.56 power (W) | CRT |
| 104 | A: Gesamtblindleistung | Gesamtblindleistung | 4 Bytes | 14.56 power (W) | CRT |
| 105 | A: Leistungsfaktor | Leistungsfaktor | 4 Bytes | 14.57 power factor (cos Φ) | CRT |
| 106 | A: Scheitelfaktor Strom | Scheitelfaktor Strom | 4 Bytes | 14.57 power factor (cos Φ) | CRT |
| 107 | Dummy | Dummy | 1 Bit | ||
| 108 | Dummy | Dummy | 1 Bit | ||
| 109 | Dummy | Dummy | 1 Bit | ||
| 110 | Dummy | Dummy | 1 Bit | ||
| 111 | Dummy | Dummy | 1 Bit | ||
| 112 | Dummy | Dummy | 1 Bit | ||
| 113 | Dummy | Dummy | 1 Bit | ||
| 114 | Dummy | Dummy | 1 Bit | ||
| 115 | Dummy | Dummy | 1 Bit | ||
| 116 | Dummy | Dummy | 1 Bit | ||
| 117 | Dummy | Dummy | 1 Bit | ||
| 118 | Dummy | Dummy | 1 Bit | ||
| 119 | Dummy | Dummy | 1 Bit | ||
| 120 | B: Schalten | Schalten | 1 Bit | CW | |
| 121 | B: Schalten | Status Schalten | 1 Bit | CRT | |
| 122 | B: Diagnose | Wirkleistung negativ | 1 Bit | CRT | |
| 123 | B: Zeit | Dauer-EIN | 1 Bit | CW | |
| 124 | B: Zeit | Funktion Zeit sperren | 1 Bit | CRWT | |
| 125 | B: Treppenlicht | Treppenlicht Zeitdauer | 2 Bytes | CRWT | |
| 126 | B: Treppenlicht | Treppenlicht Warnung | 1 Bit | CT | |
| 127 | B: Szene | 8-Bit-Szene | 1 Byte | CW | |
| 128 | B: Logik | Log. Verknüpfung 1 | 1 Bit | CW | |
| 129 | B: Logik | Log. Verknüpfung 2 | 1 Bit | CW | |
| 130 | B: Zwang | Zwangsführung | 1 Bit | CW | |
| 131 | B: Kontakt | Kontaktüberwachung | 1 Bit | CRT | |
| 132 | Dummy | Dummy | 1 Bit | ||
| 133 | Dummy | Dummy | 1 Bit | ||
| 134 | B: Hauptzähler | Zählerstand | 4 Bytes | CRT | |
| 135 | B: Zwischenzähler | Zählerstand | 4 Bytes | CRT | |
| 136 | B: Zwischenzähler | Status | 1 Byte | CRT | |
| 137 | B: Zwischenzähler | Trigger 1 empfangen | 1 Bit | CW | |
| 137 | B: Zwischenzähler | Trigger 1 Zeit ändern | 3 Bytes | 10.1 time of day | CRWT |
| 138 | B: Zwischenzähler | Trigger 2 Dauer ändern | 2 Bytes | CRWT | |
| 138 | B: Zwischenzähler | Trigger 2 Endwert ändern | 4 Bytes | CRWT | |
| 138 | B: Zwischenzähler | Trigger 2 Zeit ändern | 3 Bytes | 10.1 time of day | CRWT |
| 138 | B: Zwischenzähler | Trigger 2 empfangen | 1 Bit | CW | |
| 139 | B: Zwischenzähler | Rücksetzen | 1 Bit | CW | |
| 140 | B: Laststeuerung Slave | Laststeuerung deaktivieren | 1 Bit | 1.3 enable | CRW |
| 141 | B: Laststeuerung Slave | Abschaltstufe Ausgang | 1 Byte | 5.10 counter pulses (0..255) | CRWT |
| 142 | B: Wirkleistung | Wirkleistung | 4 Bytes | 14.56 power (W) | CRT |
| 143 | B: Wirkleistung | Schwellwert 1 untere Grenze | 4 Bytes | 14.56 power (W) | CRWT |
| 144 | B: Wirkleistung | Schwellwert 1 obere Grenze | 4 Bytes | 14.56 power (W) | CRWT |
| 145 | B: Wirkleistung | Schwellwert 1 Warnung | 1 Bit | CRT | |
| 146 | B: Wirkleistung | Schwellwert 2 untere Grenze | 4 Bytes | 14.56 power (W) | CRWT |
| 147 | B: Wirkleistung | Schwellwert 2 obere Grenze | 4 Bytes | 14.56 power (W) | CRWT |
| 148 | B: Wirkleistung | Schwellwert 2 Warnung | 1 Bit | CRT | |
| 149 | B: Strom | Stromwert | 4 Bytes | 14.19 electric current (A) | CRT |
| 150 | B: Strom | Schwellwert 1 untere Grenze | 4 Bytes | 14.19 electric current (A) | CRWT |
| 151 | B: Strom | Schwellwert 1 obere Grenze | 4 Bytes | 14.19 electric current (A) | CRWT |
| 152 | B: Strom | Schwellwert 1 Warnung | 1 Bit | CRT | |
| 153 | B: Strom | Schwellwert 2 untere Grenze | 4 Bytes | 14.19 electric current (A) | CRWT |
| 154 | B: Strom | Schwellwert 2 obere Grenze | 4 Bytes | 14.19 electric current (A) | CRWT |
| 155 | B: Strom | Schwellwert 2 Warnung | 1 Bit | CRT | |
| 156 | B: Spannung | Spannung | 4 Bytes | 14.27 electric potential (V) | CRT |
| 157 | B: Spannung | Schwellwert 1 untere Grenze | 4 Bytes | 14.27 electric potential (V) | CRWT |
| 158 | B: Spannung | Schwellwert 1 obere Grenze | 4 Bytes | 14.27 electric potential (V) | CRWT |
| 159 | B: Spannung | Schwellwert 1 Warnung | 1 Bit | CRT | |
| 160 | B: Spannung | Schwellwert 2 untere Grenze | 4 Bytes | 14.27 electric potential (V) | CRWT |
| 161 | B: Spannung | Schwellwert 2 obere Grenze | 4 Bytes | 14.27 electric potential (V) | CRWT |
| 162 | B: Spannung | Schwellwert 2 Warnung | 1 Bit | CRT | |
| 163 | B: Scheinleistung | Scheinleistung | 4 Bytes | 14.56 power (W) | CRT |
| 164 | B: Gesamtblindleistung | Gesamtblindleistung | 4 Bytes | 14.56 power (W) | CRT |
| 165 | B: Leistungsfaktor | Leistungsfaktor | 4 Bytes | 14.57 power factor (cos Φ) | CRT |
| 166 | B: Scheitelfaktor Strom | Scheitelfaktor Strom | 4 Bytes | 14.57 power factor (cos Φ) | CRT |
| 167 | Dummy | Dummy | 1 Bit | ||
| 168 | Dummy | Dummy | 1 Bit | ||
| 169 | Dummy | Dummy | 1 Bit | ||
| 170 | Dummy | Dummy | 1 Bit | ||
| 171 | Dummy | Dummy | 1 Bit | ||
| 172 | Dummy | Dummy | 1 Bit | ||
| 173 | Dummy | Dummy | 1 Bit | ||
| 174 | Dummy | Dummy | 1 Bit | ||
| 175 | Dummy | Dummy | 1 Bit | ||
| 176 | Dummy | Dummy | 1 Bit | ||
| 177 | Dummy | Dummy | 1 Bit | ||
| 178 | Dummy | Dummy | 1 Bit | ||
| 179 | Dummy | Dummy | 1 Bit | ||
| 180 | C: Schalten | Schalten | 1 Bit | CW | |
| 181 | C: Schalten | Status Schalten | 1 Bit | CRT | |
| 182 | C: Diagnose | Wirkleistung negativ | 1 Bit | CRT | |
| 183 | C: Zeit | Dauer-EIN | 1 Bit | CW | |
| 184 | C: Zeit | Funktion Zeit sperren | 1 Bit | CRWT | |
| 185 | C: Treppenlicht | Treppenlicht Zeitdauer | 2 Bytes | CRWT | |
| 186 | C: Treppenlicht | Treppenlicht Warnung | 1 Bit | CT | |
| 187 | C: Szene | 8-Bit-Szene | 1 Byte | CW | |
| 188 | C: Logik | Log. Verknüpfung 1 | 1 Bit | CW | |
| 189 | C: Logik | Log. Verknüpfung 2 | 1 Bit | CW | |
| 190 | C: Zwang | Zwangsführung | 1 Bit | CW | |
| 191 | C: Kontakt | Kontaktüberwachung | 1 Bit | CRT | |
| 192 | Dummy | Dummy | 1 Bit | ||
| 193 | Dummy | Dummy | 1 Bit | ||
| 194 | C: Hauptzähler | Zählerstand | 4 Bytes | CRT | |
| 195 | C: Zwischenzähler | Zählerstand | 4 Bytes | CRT | |
| 196 | C: Zwischenzähler | Status | 1 Byte | CRT | |
| 197 | C: Zwischenzähler | Trigger 1 empfangen | 1 Bit | CW | |
| 197 | C: Zwischenzähler | Trigger 1 Zeit ändern | 3 Bytes | 10.1 time of day | CRWT |
| 198 | C: Zwischenzähler | Trigger 2 Dauer ändern | 2 Bytes | CRWT | |
| 198 | C: Zwischenzähler | Trigger 2 Endwert ändern | 4 Bytes | CRWT | |
| 198 | C: Zwischenzähler | Trigger 2 Zeit ändern | 3 Bytes | 10.1 time of day | CRWT |
| 198 | C: Zwischenzähler | Trigger 2 empfangen | 1 Bit | CW | |
| 199 | C: Zwischenzähler | Rücksetzen | 1 Bit | CW | |
| 200 | C: Laststeuerung Slave | Laststeuerung deaktivieren | 1 Bit | 1.3 enable | CRW |
| 201 | C: Laststeuerung Slave | Abschaltstufe Ausgang | 1 Byte | 5.10 counter pulses (0..255) | CRWT |
| 202 | C: Wirkleistung | Wirkleistung | 4 Bytes | 14.56 power (W) | CRT |
| 203 | C: Wirkleistung | Schwellwert 1 untere Grenze | 4 Bytes | 14.56 power (W) | CRWT |
| 204 | C: Wirkleistung | Schwellwert 1 obere Grenze | 4 Bytes | 14.56 power (W) | CRWT |
| 205 | C: Wirkleistung | Schwellwert 1 Warnung | 1 Bit | CRT | |
| 206 | C: Wirkleistung | Schwellwert 2 untere Grenze | 4 Bytes | 14.56 power (W) | CRWT |
| 207 | C: Wirkleistung | Schwellwert 2 obere Grenze | 4 Bytes | 14.56 power (W) | CRWT |
| 208 | C: Wirkleistung | Schwellwert 2 Warnung | 1 Bit | CRT | |
| 209 | C: Strom | Stromwert | 4 Bytes | 14.19 electric current (A) | CRT |
| 210 | C: Strom | Schwellwert 1 untere Grenze | 4 Bytes | 14.19 electric current (A) | CRWT |
| 211 | C: Strom | Schwellwert 1 obere Grenze | 4 Bytes | 14.19 electric current (A) | CRWT |
| 212 | C: Strom | Schwellwert 1 Warnung | 1 Bit | CRT | |
| 213 | C: Strom | Schwellwert 2 untere Grenze | 4 Bytes | 14.19 electric current (A) | CRWT |
| 214 | C: Strom | Schwellwert 2 obere Grenze | 4 Bytes | 14.19 electric current (A) | CRWT |
| 215 | C: Strom | Schwellwert 2 Warnung | 1 Bit | CRT | |
| 216 | C: Spannung | Spannung | 4 Bytes | 14.27 electric potential (V) | CRT |
| 217 | C: Spannung | Schwellwert 1 untere Grenze | 4 Bytes | 14.27 electric potential (V) | CRWT |
| 218 | C: Spannung | Schwellwert 1 obere Grenze | 4 Bytes | 14.27 electric potential (V) | CRWT |
| 219 | C: Spannung | Schwellwert 1 Warnung | 1 Bit | CRT | |
| 220 | C: Spannung | Schwellwert 2 untere Grenze | 4 Bytes | 14.27 electric potential (V) | CRWT |
| 221 | C: Spannung | Schwellwert 2 obere Grenze | 4 Bytes | 14.27 electric potential (V) | CRWT |
| 222 | C: Spannung | Schwellwert 2 Warnung | 1 Bit | CRT | |
| 223 | C: Scheinleistung | Scheinleistung | 4 Bytes | 14.56 power (W) | CRT |
| 224 | C: Gesamtblindleistung | Gesamtblindleistung | 4 Bytes | 14.56 power (W) | CRT |
| 225 | C: Leistungsfaktor | Leistungsfaktor | 4 Bytes | 14.57 power factor (cos Φ) | CRT |
| 226 | C: Scheitelfaktor Strom | Scheitelfaktor Strom | 4 Bytes | 14.57 power factor (cos Φ) | CRT |
| 227 | Dummy | Dummy | 1 Bit | ||
| 228 | Dummy | Dummy | 1 Bit | ||
| 229 | Dummy | Dummy | 1 Bit | ||
| 230 | Dummy | Dummy | 1 Bit | ||
| 231 | Dummy | Dummy | 1 Bit | ||
| 232 | Dummy | Dummy | 1 Bit | ||
| 233 | Dummy | Dummy | 1 Bit | ||
| 234 | Dummy | Dummy | 1 Bit | ||
| 235 | Dummy | Dummy | 1 Bit | ||
| 236 | Dummy | Dummy | 1 Bit | ||
| 237 | Dummy | Dummy | 1 Bit | ||
| 238 | Dummy | Dummy | 1 Bit | ||
| 239 | Dummy | Dummy | 1 Bit | ||
| 240 | Allgemein | 1 Bit | CWT | ||
| 241 | Allgemein | 4 Bytes | |||
| 242 | Allgemein | 4 Bytes | CWT | ||
| 243 | Allgemein | 4 Bytes | |||
| 244 | Allgemein | 4 Bytes | CWT | ||
| 245 | Allgemein | 4 Bytes | |||
| 246 | Allgemein | 4 Bytes | |||
| 247 | Allgemein | 4 Bytes | CWT | ||
| 248 | Allgemein | 4 Bytes | |||
| 249 | Allgemein | 4 Bytes | |||
| 250 | Allgemein | 4 Bytes | CWT | ||
| 251 | Allgemein | 4 Bytes | |||
| 252 | Allgemein | 4 Bytes | |||
| 253 | Allgemein | 4 Bytes |
Parameters (285)
| Parameter | Type | Default |
|---|---|---|
| Allgemein | unsignedInt 0…1 | 0 |
| Sendeverzögerung nach Busspannungswiederkehr in s [2...255] | unsignedInt 2…255 | 2 |
| Kommunikationsobjekt "In Betrieb" senden | list | nein |
| Sendezykluszeit in s [1...65.535] | unsignedInt 1…65535 | 60 |
| Telegram is repeated every in s [1...65,535] | unsignedInt 0…65535 | 0 |
| Anzahl Telegramme begrenzen | list | nein |
| Maximale Anzahl gesendeter Telegramme | unsignedInt 1…255 | 20 |
| Maximale Anzahl gesendeter Telegramme [1...255] | unsignedInt 1…255 | 20 |
| Im Zeitraum | list | 100 ms |
| Kommunikationsobjekt freigeben "Statuswerte anfordern" 1 Bit | list | nein |
| Anfordern bei Objektwert | list | 1 |
| Kommunikationsobjekt freigeben "Instrumentenwerte anfordern" 1 Bit | list | nein |
| Kommunikationsobjekt freigeben "Leistungswerte anfordern" 1 Bit | list | nein |
| Sendezykluszeit Instrumentenwerte in s [0...65.535, 0 = nicht zykl. senden] | unsignedInt 0…65535 | 900 |
| Sendezykluszeit Leistungswerte in s [0..65.535, 0 = nicht zykl. senden] | unsignedInt 0…65535 | 900 |
| Zählen (Wh) | unsignedInt 0…1 | 0 |
| Kommunikationsobjekt freigeben "Zählerstände anfordern" 1 Bit | list | nein |
| Sendeverzögerung Zählerstände in s [0...65.535] | unsignedInt 0…65535 | 0 |
| Sendezykluszeit Zählerstände in s [0...172.800, 0 = nicht zykl. senden] | unsignedInt 0…172800 | 900 |
| Alle Zähler gemeinsam über Objekt rücksetzbar | list | nein |
| Alle Zähler werden zurück- gesetzt und gestoppt. | list | <--- HINWEIS |
| "Zähler Gesamt" freigeben | list | nein |
| Funktion | unsignedInt 0…1 | 0 |
| "Wirkleistung Gesamt" überwachen | list | nein |
| "Frequenz" überwachen | list | nein |
| Gerät ist Laststeuerung Master | list | nein |
| Kommunikationsobjekt freigeben "Abschaltstufe empfangen" | list | nein |
| Wird benötigt, sobald min. 1 Ausgang als Laststeuerung Slave parametriert ist. | list | <--- HINWEIS |
| Gerätesicherheitsobjekte freigeben | list | nein |
| Funktion Sicherheit Priorität 1 | list | inaktiv |
| Überwachungszeit in s (0...65.535, 0 = inaktiv) | unsignedInt 0…65535 | 0 |
| Überwachungszeit in s (0...65.535, 0 = inaktiv) | unsignedInt 0…65535 | 0 |
| Funktion Sicherheit Priorität 2 | list | inaktiv |
| Funktion Sicherheit Priorität 3 | list | inaktiv |
| Zähler Gesamt (Wh) | unsignedInt 0…1 | 0 |
| "Hauptzähler Gesamt" senden | list | nein, nur aktualisieren |
| Send "Intermediate meter reading total" | list | ja |
| Einstellung Zykluszeit und Anforderung im Parameterfenster "Zählen" | list | <--- HINWEIS |
| "Zwischenzähler Gesamt" senden | list | nein, nur aktualisieren |
| Trigger 1 (Start) wird ausgelöst durch | list | 1-Bit-Kommunikationsobjekt |
| Stunde [0...23] | unsignedInt 0…23 | 0 |
| Minute [0...59] | unsignedInt 0…59 | 0 |
| Wochentag | list | jeden Tag |
| Bei Trigger 1 (Start) "Zwischenzähler Gesamt" zurücksetzen | list | ja |
| Bei Trigger 1 (Start) "Zwischenzähler Gesamt" senden | list | ja |
| Trigger 2 wird ausgelöst durch | list | 1-Bit-Kommunikationsobjekt |
| Dauer in min [1...65.535] | unsignedInt 0…65535 | 5 |
| Endwert in Wh [1...120.888.000] | unsignedInt 1…120888000 | 5000 |
| Bei Trigger 2 wird Zählwert versendet | list | <--- HINWEIS |
| Bei Trigger 2 "Zwischenzähler Gesamt" stoppen | list | ja |
| "Zwischenzähler Gesamt" zusätzlich rücksetzbar über Objekt | list | nein |
| Wert wird beim Rücksetzen gesendet. | list | <--- HINWEIS |
| Param. Start-Stoppzeit, Dauer u. Endwert nach Download und ETS-Reset übernehmen | list | ja |
| Wirkleistung Gesamt | unsignedInt 0…1 | 0 |
| "Wirkleistung" bei Änderung senden | list | nein |
| "Wirkleistung" senden bei +/- W [1 ... 13.800] | unsignedInt 1…13800 | 20 |
| "Wirkleistung" bei Anforderung senden | list | nein |
| "Wirkleistung" zyklisch senden | list | nein |
| Einstellung Zykluszeit und Anforderung im Parameterfenster "Allgemein" | list | <--- HINWEIS |
| Schwellwerte freigeben | list | nein |
| Delay for switching in s [0...65.535] | unsignedInt 0…65535 | 0 |
| Parametrierte Schwellwerte nach Download und ETS-Reset übernehmen | list | nein |
| Schwellwert 1 untere Grenze in W [0...13.800] | unsignedInt 0…13800 | 90 |
| Schwellwert 1 obere Grenze in W [0...13.800] | unsignedInt 0…13800 | 100 |
| Schwellwert 1 Warnung | list | nicht senden |
| Schwellwert 2 freigeben | list | nein |
| Schwellwert 2 untere Grenze in W [0...13.800] | unsignedInt 0…13800 | 800 |
| Schwellwert 2 obere Grenze in W [0...13.800] | unsignedInt 0…13800 | 1000 |
| Schwellwert 2 Warnung | list | nicht senden |
| Frequenz | unsignedInt 0…1 | 0 |
| "Frequenz" bei Änderung senden | list | nein |
| "Frequenz" senden bei +/- 0,1 Hz * Wert [1...650] | unsignedInt 1…650 | 5 |
| "Frequenz" bei Anforderung senden | list | nein |
| "Frequenz" zyklisch senden | list | nein |
| Delay for switching in s [0...65,535] | unsignedInt 0…65535 | 0 |
| Schwellwert 1 untere Grenze in 0,1 Hz * Wert [1...650] | unsignedInt 1…650 | 450 |
| Schwellwert 1 obere Grenze in 0,1 Hz * Wert [1...650] | unsignedInt 1…650 | 500 |
| Schwellwert 2 untere Grenze in 0,1 Hz * Wert [1...650] | unsignedInt 1…650 | 450 |
| Schwellwert 2 obere Grenze in 0,1 Hz * Wert [1...650] | unsignedInt 1…650 | 500 |
| Laststeuerung Master | unsignedInt 0…1 | 0 |
| Anzahl Abschaltstufen [1...8] | unsignedInt 1…8 | 2 |
| Lastgrenze über Bus änderbar | list | ja, Kommunikationsobjekt beschreibbar |
| Lastgrenze in W [0...200.000] | unsignedInt 0…200000 | 5000 |
| Parametrierte Lastgrenze nach Download und ETS-Reset übernehmen | list | ja |
| Lastgrenze 1 in W [0...200.000] | unsignedInt 0…200000 | 5000 |
| Lastgrenze 2 in W [0...200.000] | unsignedInt 0…200000 | 5000 |
| Lastgrenze 3 in W [0...200.000] | unsignedInt 0…200000 | 5000 |
| Lastgrenze 4 in W [0...200.000] | unsignedInt 0…200000 | 5000 |
| Aktive Lastgrenze nach Download und ETS-Reset | list | Lastgrenze 1 |
| Quelle für Leistungswert 1 | list | keine |
| Quelle für Leistungswert 2 | list | keine |
| Quelle für Leistungswert 3 | list | keine |
| Quelle für Leistungswert 4 | list | keine |
| Anzahl weiterer Leistungswerte [0...6] | unsignedInt 0…6 | 0 |
| Leistungswerte zyklisch überwachen | list | nein |
| Überwachungszeit in s [20...65.535] | unsignedInt 20…65535 | 20 |
| Reaktionszeit beim Überschreiten der Lastgrenze in s [2...60] | unsignedInt 2…60 | 2 |
| Reaktionszeit beim Unterschreiten der Lastgrenze in s [30...65.535] | unsignedInt 30…65535 | 300 |
| Hysterese beim Wiedereinschaltversuch in % der Lastgrenze [0...100] | unsignedInt 0…100 | 0 |
| Objektwert "Laststeuerung deaktivieren" (Master) nach Busspannungswiederkehr | list | unverändert |
| Output A | unsignedInt 0…1 | 0 |
| A: Allgemein | unsignedInt 0…1 | 0 |
| Statusmeldung des Schaltzustandes | list | nein |
| Senden | list | nein, nur aktualisieren |
| Invertieren | list | nein: 0 = geöffnet, 1 = geschlossen |
| Ansteuerung der Relaisspule | list | nur bei berechneter Änderung ausführen |
| Evtl. erfolgtes manuelles Schalten wird berücksichtigt. | list | <--- HINWEIS |
| Auswerteverzögerung | list | 300 ms |
| Gilt für Kontaktüberwachung, Instrumenten- und Leistungswerte | list | <--- HINWEIS |
| Status Kontaktüberwachung senden | list | nein, nur aktualisieren |
| Verhalten bei Busspannungsausfall | list | Kontakt unverändert |
| Wert des Objekts "Schalten" bei Busspannungswiederkehr und ETS-Reset | list | nicht beschreiben |
| Freigabe Objekte "Statuswerte anfordern" im Parameterfenster "Allgemein" | list | <--- HINWEIS |
| A: Funktion | unsignedInt 0…1 | 0 |
| Funktion Zeit: Verzögerung, Treppenlicht Blinken freigeben | list | nein |
| Wert des Objekts "Funktion Zeit sperren" bei BSW und ETS-Reset | list | 0 = Funktion Zeit freigegeben |
| Funktion Szene (8 Bit) freigeben | list | nein |
| Parametrierte Szenenzuordnungen nach Download und ETS-Reset übernehmen | list | ja |
| Funktion Verknüpfung/Logik freigeben | list | nein |
| Funktion Sicherheit freigeben | list | nein |
| Funktion Zählen freigeben | list | nein |
| Funktion Instrumenten- u. Leistungswerte freigeben | list | nein |
| Funktion Laststeuerung Slave freigeben | list | nein |
| A: Zeit | unsignedInt 0…1 | 0 |
| Funktion Zeit | list | Treppenlicht |
| Blinken wenn Kommunikationsobjekt "Schalten" gleich | list | 1 oder 0 |
| Nach Beendigung von Dauer-EIN startet Treppenlicht neu | list | nein |
| Zeitdauer für EIN in s [1...65.535] | unsignedInt 1…65535 | 5 |
| Einschaltverzögerung in s [0...65.535] | unsignedInt 0…65535 | 0 |
| Treppenlicht Zeitdauer in s [0...65.535] | unsignedInt 0…65535 | 300 |
| Zeitdauer für AUS in s [1...65.535] | unsignedInt 1…65535 | 5 |
| Ausschaltverzögerung in s [0...65.535] | unsignedInt 0…65535 | 0 |
| Anzahl der Impulse: [1...100] | unsignedInt 1…100 | 5 |
| Treppenlichtzeit verlängert sich bei mehrfachem Einschalten ("Pumpen") | list | ja (retriggerbar) |
| Zustand des Schaltkontakts nach dem Blinken | list | aktualisiert Schaltzustand |
| Treppenlicht schaltbar | list | EIN mit 1 und AUS mit 0 |
| Warnung vor Auslauf des Treppenlichts | list | nein |
| Warnzeit in s [0...65.535] verlängert Treppenlicht Zeitdauer | unsignedInt 0…65535 | 0 |
| Treppenlicht Zeitdauer über Objekt "Treppenlicht Zeitdauer" ändern | list | nein |
| Hinweis: Kontaktlebensdauer und Schalt- spiele pro Minute sind zu beachten | list | siehe Technische Daten |
| A: Szenen 1...6 | unsignedInt 0…1 | 0 |
| Zuordnung zu Szenennummer 1...64 | list | keine Zuordnung |
| Standardwert | list | EIN |
| Weitere Szenen freigeben | list | nein |
| A: Szenen 7...12 | unsignedInt 0…1 | 0 |
| A: Szenen 13...18 | unsignedInt 0…1 | 0 |
| A: Logik | unsignedInt 0…1 | 0 |
| Verknüpfungsobjekt 1 | list | inaktiv |
| Funktion von Verknüpfungsobjekt 1 | list | UND |
| TOR sperrt, wenn Objektwert "Log. Verknüpfung 1" gleich | list | 0 |
| Ergebnis invertieren | list | nein |
| Objektwert "Log. Verknüpfung 1" nach BSW und ETS-Reset | list | 0 |
| Verknüpfungsobjekt 2 | list | inaktiv |
| Funktion von Verknüpfungsobjekt 2 | list | UND |
| TOR sperrt, wenn Objektwert "Log. Verknüpfung 2" gleich | list | 0 |
| Objektwert "Log. Verknüpfung 2" nach BSW und ETS-Reset | list | 0 |
| A: Sicherheit | unsignedInt 0…1 | 0 |
| Die Reihenfolge gibt die Priorität der Zwangsführungen an | list | <--- HINWEIS |
| Aktivierung "Sicherheit Priorität x" im Parameterfenster "Funktion" | list | <--- HINWEIS |
| Schaltzustand bei Sicherheit Priorität 1 | list | inaktiv |
| Schaltzustand bei Zwangsführung | list | inaktiv |
| Objektwert "Zwangsführung" nach BSW und ETS-Reset | list | inaktiv |
| Objektwert "Zwangsführung" nach BSW und ETS-Reset | list | 0 = inaktiv |
| Schaltzustand bei Sicherheit Priorität 2 | list | inaktiv |
| Schaltzustand bei Sicherheit Priorität 3 | list | inaktiv |
| Schaltzustand bei Ende der Zwangsführung und aller Sicherheits Prioritäten | list | aktualisiert Schaltzustand |
| A: Zähler (Wh) | unsignedInt 0…1 | 0 |
| "Hauptzähler" senden | list | nein, nur aktualisieren |
| Enable "Intermediate meter reading" | list | ja |
| "Zwischenzähler" senden | list | nein, nur aktualisieren |
| Bei Trigger 1 (Start) "Zwischenzähler" zurücksetzen | list | ja |
| Bei Trigger 1 (Start) "Zwischenzähler" senden | list | ja |
| Dauer in min [1...65.535 min] | unsignedInt 1…65535 | 5 |
| Endwert in Wh [1...40.296.000] | unsignedInt 1…40296000 | 5000 |
| Bei Trigger 2 "Zwischenzähler" stoppen | list | ja |
| Reaktion bei Stopp | list | keine Reaktion |
| Reaktion beim Erreichen des Endwertes | list | keine Reaktion |
| "Zwischenzähler" zusätzlich rücksetzbar über Objekt | list | nein |
| A: Instrumenten- u. Leistungswerte | list | nein |
| Wirkleistung überwachen | list | nein |
| Stromwert überwachen | list | nein |
| Spannung überwachen | list | nein |
| Kommunikationsobjekt freigeben "Scheinleistung" | list | nein |
| "Scheinleistung" bei Änderung senden | list | nein |
| "Scheinleistung" senden bei +/- VA [1...4.600] | unsignedInt 0…4600 | 5 |
| "Scheinleistung" bei Anforderung senden | list | nein |
| "Scheinleistung" zyklisch senden | list | nein |
| Kommunikationsobjekt freigeben "Leistungsfaktor" | list | nein |
| "Leistungsfaktor" bei Änderung senden | list | nein |
| "Leistungsfaktor" senden bei +/- 0,01 * Wert [1...100] | unsignedInt 1…100 | 5 |
| "Leistungsfaktor" bei Anforderung senden | list | nein |
| "Leistungsfaktor" zyklisch senden | list | nein |
| Kommunikationsobjekt freigeben "Scheitelfaktor" | list | nein |
| "Scheitelfaktor" bei Änderung senden | list | nein |
| "Scheitelfaktor" senden bei +/- 0,1 * Wert [1...100] | unsignedInt 1…100 | 5 |
| "Scheitelfaktor" bei Anforderung senden | list | nein |
| "Scheitelfaktor" zyklisch senden | list | nein |
| A: Wirkleistung überwachen | unsignedInt 0…1 | 0 |
| "Wirkleistung" senden bei +/- W [1...4.600] | unsignedInt 1…4600 | 5 |
| Verweildauer bis Schaltreaktion in s [0...65.535] | unsignedInt 0…65535 | 1 |
| Auswertung Schwellwert 1 | list | immer |
| Schwellwert 1 untere Grenze in W [0...4.600] | unsignedInt 0…4600 | 5 |
| Schwellwert 1 obere Grenze in W [0...4.600] | unsignedInt 0…4600 | 100 |
| Schaltreaktion bei Unterschreiten untere Grenze | list | keine Reaktion |
| Schaltreaktion bei Überschreiten obere Grenze | list | keine Reaktion |
| Auswertung Schwellwert 2 | list | immer |
| Schwellwert 2 untere Grenze in W [0...4.600] | unsignedInt 0…4600 | 5 |
| Schwellwert 2 obere Grenze in W [0...4.600] | unsignedInt 0…4600 | 100 |
| Schaltreaktion bei Unterschreiten untere Grenze | list | keine Reaktion |
| Schaltreaktion bei Überschreiten obere Grenze | list | keine Reaktion |
| A: Stromwert überwachen | unsignedInt 0…1 | 0 |
| "Stromwert" bei Änderung senden | list | nein |
| "Stromwert" senden bei +/- mA [1...20.000] | unsignedInt 1…20000 | 50 |
| "Stromwert" bei Anforderung senden | list | nein |
| "Stromwert" zyklisch senden | list | nein |
| Schwellwert 1 untere Grenze in 100 mA * Wert [0...200] | unsignedInt 0…200 | 1 |
| Schwellwert 1 obere Grenze in 100 mA * Wert [0...200] | unsignedInt 0…200 | 3 |
| Schwellwert 2 untere Grenze in 100 mA * Wert [0...200] | unsignedInt 0…200 | 180 |
| Schwellwert 2 obere Grenze in 100 mA * Wert [0...200] | unsignedInt 0…200 | 200 |
| A: Spannung überwachen | unsignedInt 0…1 | 0 |
| "Spannung" bei Änderung senden | list | nein |
| "Spannung" senden bei +/- V [1...265] | unsignedInt 1…265 | 5 |
| "Spannung" bei Anforderung senden | list | nein |
| "Spannung" zyklisch senden | list | nein |
| Schwellwert 1 untere Grenze in V [95...265] | unsignedInt 95…265 | 95 |
| Schwellwert 1 obere Grenze in V [95...265] | unsignedInt 95…265 | 100 |
| Schwellwert 2 untere Grenze in V [95...265] | unsignedInt 95…265 | 260 |
| Schwellwert 2 obere Grenze in V [95...265] | unsignedInt 95…265 | 265 |
| A: Laststeuerung Slave | unsignedInt 0…1 | 0 |
| Abschaltstufe Ausgang [1...8] | unsignedInt 1…8 | 1 |
| Abschaltstufe über Bus änderbar | list | nein |
| Parametrierte Abschaltstufe nach Download und ETS-Reset übernehmen | list | ja |
| Slave wird gesteuert über | list | externes Kommunikationsobjekt |
| Objekt "Abschaltstufe Empfangen" im Parameterfenster"Funktion" freigeben. | list | <--- HINWEIS |
| Sofern Gerät gleichzeitig Master. | list | <--- HINWEIS |
| Objektwert "Laststeuerung deaktivieren" (Slave) nach Busspannungswiederkehr | list | unverändert |
| Output B | unsignedInt 0…1 | 0 |
| B: Allgemein | unsignedInt 0…1 | 0 |
| Gilt für Kontaktüberwachung und Instrumenten- und Leistungswerte | list | <--- HINWEIS |
| B: Funktion | unsignedInt 0…1 | 0 |
| Wert des Objekts "Funktion Zeit sperren" bei BSW und ETS-Reset | list | 0 = Funktion Zeit freigegeben |
| Funktion Instrumenten- u. Leistungswerte freigeben | list | nein |
| B: Zeit | unsignedInt 0…1 | 0 |
| Zeitdauer für EIN in s [1...65.535] | unsignedInt 1…65535 | 5 |
| Treppenlicht Zeitdauer in s [0...65.535] | unsignedInt 0…65535 | 300 |
| Einschaltverzögerung in s [0...65.535] | unsignedInt 0…65535 | 0 |
| Zeitdauer für AUS in s [1...65.535] | unsignedInt 1…65535 | 5 |
| Ausschaltverzögerung in s [0...65.535] | unsignedInt 0…65535 | 45 |
| Anzahl der Impulse: (1...100) | unsignedInt 1…100 | 5 |
| Warnzeit in s [0...65.535] verlängert Treppenlicht Zeitdauer | unsignedInt 0…65535 | 45 |
| B: Szenen 1...6 | unsignedInt 0…1 | 0 |
| B: Szenen 7...12 | unsignedInt 0…1 | 0 |
| B: Szenen 13...18 | unsignedInt 0…1 | 0 |
| B: Logik | unsignedInt 0…1 | 0 |
| B: Sicherheit | unsignedInt 0…1 | 0 |
| B: Zähler (Wh) | unsignedInt 0…1 | 0 |
| B: Instrumenten- u. Leistungswerte | list | nein |
| B: Wirkleistung überwachen | unsignedInt 0…1 | 0 |
| B: Stromwert überwachen | unsignedInt 0…1 | 0 |
| "Strom" senden bei +/- mA [1...20.000] | unsignedInt 1…20000 | 50 |
| B: Spannung überwachen | unsignedInt 0…1 | 0 |
| B: Laststeuerung Slave | unsignedInt 0…1 | 0 |
| Objekt "Abschaltstufe Empfangen" im Parameterfenster "Funktion" freigeben. | list | <--- HINWEIS |
| Output C | unsignedInt 0…1 | 0 |
| C: Allgemein | unsignedInt 0…1 | 0 |
| Gilt für Kontaktüberwachung und Instrumenten- u. Leistungswerte | list | <--- HINWEIS |
| C: Funktion | unsignedInt 0…1 | 0 |
| C: Zeit | unsignedInt 0…1 | 0 |
| C: Szenen 1...6 | unsignedInt 0…1 | 0 |
| C: Szenen 7...12 | unsignedInt 0…1 | 0 |
| C: Szenen 13...18 | unsignedInt 0…1 | 0 |
| C: Logik | unsignedInt 0…1 | 0 |
| C: Sicherheit | unsignedInt 0…1 | 0 |
| C: Zähler (Wh) | unsignedInt 0…1 | 0 |
| Dauer in min [1...65.535] | unsignedInt 1…65535 | 5 |
| C: Instrumenten- u. Leistungswerte | list | nein |
| "Leistungsfaktor" bei Anforderung senden | list | nein |
| "Scheitelfaktor" bei Anforderung | list | nein |
| C: Wirkleistung überwachen | unsignedInt 0…1 | 0 |
| C: Stromwert überwachen | unsignedInt 0…1 | 0 |
| C: Spannung überwachen | unsignedInt 0…1 | 0 |
| C: Laststeuerung Slave | unsignedInt 0…1 | 0 |
| Notes | list | nein |
| Hinweise für SE/S | unsignedInt 0…1 | 0 |
| Maustaste auf Gerät in ETS-Topologie) | list |
Version history
| Application | App no | Fingerprint | First seen | Size | File |
|---|---|---|---|---|---|
| Measure 3f/1.0b 1.0 latest | $A07E | 5EC2 | 2026-11-25 | 596 KB | Download |
About this file
This is the official ETS product database for the ABB AG - STOTZ-KONTAKT EM/S3.16.1 Energy Module,3F,16/20A,MDRC (2CDG 110 148 R0011), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.
More from ABB AG - STOTZ-KONTAKT
- ZS/S1.1 Meter Interface Module,MDRC 2CDG 110 083 R0011
- SE/S3.16.1 Energy Actuator,3-fold,16/20A,MDRC 2CDG 110 136 R0011
- QA/S1.16.1 Energy Analyzer, 16-fold, MDRC 2CDG 110 224 R0011
- PS5604-KNX AC500 1SAP 195 800 R0101
- EG/A32.2.1 KNX/EnOcean Gateway 2 CDG 120 047 R0011
- Sidus KNX Tastsensor 1-/2-fach, UP 2CCA 380 319 R0001
- Sidus KNX control element 2/4gang, flush-mounted 2CCA 380 339 R0001
- Sidus KNX Tastsensor 4-/8-fach, UP 2CCA 380 375 R0001
- Sidus KNX Movement detector 180° flat 2CCA 388 975 R0001
- Sidus KNX Room temperature controller, FM 2CCA388429R0001
- PM/A 2.8.x.1 Presence detector premium 2CDG 0006 132 R0348
- SBB/U1.1.1 ctrl. el., solo® stand., 1gang, fl. mtd. 2CDG 006 115 R0183