ABB AG - BUSCH-JAEGER 6119/40 6119/40 4f-Universalschnittstelle, UP

6119/40 4f-Universalschnittstelle, UP 6119/40

ABB AG - BUSCH-JAEGER · Order number 6119/40 · Standard Inputs › Universal Interfaces

Binary Input Display Heat, 4f/1.3a

Download .knxprod Binary Input Display Heat, 4f/1.3a 1.3 · 212 KB

Product

ManufacturerABB AG - BUSCH-JAEGER
Product name6119/40 4f-Universalschnittstelle, UP
Order number6119/40
Product text4fach Universalschnittstelle 6119/40
Hardware4fach Universalschnittstelle 6119/40
MediumTwisted Pair
Bus current (mA)10
Rail mountedNo
RegistrationRegistered · 2002-10-15
Languagesde-DE, en-US
Catalog entryM-0007_H-2.20.2F.2F.20GHQ.20631.200070-1-O0002_HP-A001-13-A05E-O0002_CI-6119.2F40-3
FingerprintA05E
SHA-2569735020283afb798210b78c8d37b3471117ee1b827dfe5011a69674bd46b8a73
First seen2026-11-25
MarketsAustria, Belgium, Germany, Netherlands

Application program: Binary Input Display Heat, 4f/1.3a 1.3

Application number$A001
Version1.3
Mask versionMV-0701 (7.1)
KNX Data SecureNo
Parameters738
Group objects286
Group objects (286)
NoNameFunctionSizeDPTFlags
0Input ADisable1 BitCW
1Input ATelegr. counter value 2 bytes2 BytesCWT
1Input ATelegr. counter value 4 bytes4 BytesCWT
1Input ATelegr. counter value 1 byte1 ByteCWT
1Input ATelegr. switch1 BitCWT
1Input ATelegr. operation 1-fold1 BitCWT
1Input A -shortTelegr. switch1 BitCWT
1Input ATelegr. shutter UP/DOWN1 BitCT
1Input ATelegr. value 11 BitCWT
1Input ATelegr. value [-32768...32767]2 BytesCT
1Input ATelegr. value [0...4294967295]4 BytesCT
1Input ATelegr. value (temperature)2 BytesCT
1Input ATelegr. value (forced position)2 BitCT
1Input ATelegr. value [0...255]1 ByteCT
1Input ATelegr. value [0...65535]2 BytesCT
1Input A -shortTelegr. value (0,1)1 BitCT
1Input A -shortTelegr. value [-32768...32767]2 BytesCT
1Input A -shortTelegr. value [0...4294967295]4 BytesCT
1Input A -shortTelegr. value (temperature)2 BytesCT
1Input A -shortTelegr. value (forced position)2 BitCT
1Input A -shortTelegr. value [0...255]1 ByteCT
1Input A -shortTelegr. value [0...65535]2 BytesCT
1Input ATelegr. value actuator group A1 ByteCWTU
1Input ASwitch actuator group A1 BitCWTU
1Input A8-bit-scene1 ByteCT
1Output ALED, switching1 BitCW
1Output AControl value (PWM)1 ByteCW
1Output ATelegr. switch1 BitCW
2Input ADifferential counter 2 bytes2 BytesCWT
2Input A -longTelegr. switch -long1 BitCT
2Input ADifferential counter 4 bytes4 BytesCWT
2Input ADifferential counter 1 byte1 ByteCWT
2Input ATelegr. operation 2-fold1 BitCWT
2Input ATelegr. dimming4 BitCT
2Input ATelegr. STOP / lamella adj.1 BitCT
2Input ATelegr. value 21 BitCWT
2Input A -longTelegr. value (0,1)1 BitCT
2Input A -longTelegr. value [-32768...32767]2 BytesCT
2Input A -longTelegr. value [0...4294967295]4 BytesCT
2Input A -longTelegr. value (forced position)2 BitCT
2Input A -longTelegr. value [0...255]1 ByteCT
2Input A -longTelegr. value [0...65535]2 BytesCT
2Input ATelegr. value actuator group B1 ByteCWTU
2Input ASwitch actuator group B1 BitCWTU
2Output ALED, flashing1 BitCW
2Input A -longTelegr. value (temperature)2 BytesCT
3Input ARequest counter values1 BitCW
3Input ATelegr. operation 3-fold1 BitCWT
3Input AUpper limit position1 BitCW
3Input ATelegr. value 31 BitCWT
3Input ATelegr. value actuator group C1 ByteCWTU
3Input ASwitch actuator group C1 BitCWTU
3Output ALED permanent ON1 BitCW
3Output Avalve purge1 BitCW
4Input ADifferential counter overflow1 BitCT
4Input ATelegr. operation 4-fold1 BitCWT
4Input ALower limit position1 BitCW
4Input ATelegr. value 41 BitCWT
4Input ATelegr. value actuator group D1 ByteCWTU
4Input ASwitch actuator group D1 BitCWTU
4Output ATelegr. status/ackn.1 BitCT
4Output AForced positioning1 BitCW
5Input AReset differential counter1 BitCW
5Input ATelegr. value 51 BitCWT
5Input ATelegr. value actuator group E1 ByteCWTU
5Input ASwitch actuator group E1 BitCWTU
5Output ATelegr. status/ackn.1 BitCT
6Input ALevel increment/decrement1 BitCW
6Input ATelegr. operation long1 BitCT
6Input AStore scene1 BitCWT
6Output ATelegr. fault1 BitCT
7Input BDisable1 BitCW
8Output BControl value (PWM)1 ByteCW
8Output BTelegr. switch1 BitCW
8Input BTelegr. switch1 BitCWT
8Input BTelegr. counter value 2 bytes2 BytesCWT
8Input BTelegr. counter value 1 byte1 ByteCWT
8Input BTelegr. counter value 4 bytes4 BytesCWT
8Input BTelegr. operation 1-fold1 BitCWT
8Input BTelegr. value 11 BitCWT
8Output BLED, switching1 BitCW
8Input BTelegr. value actuator group A1 ByteCWTU
8Input BSwitch actuator group A1 BitCWTU
8Input B8-bit-scene1 ByteCT
8Input BTelegr. value [-32768...32767]2 BytesCT
8Input BTelegr. value [0...4294967295]4 BytesCT
8Input BTelegr. value (temperature)2 BytesCT
8Input BTelegr. value (forced position)2 BitCT
8Input BTelegr. value [0...255]1 ByteCT
8Input BTelegr. value [0...65535]2 BytesCT
8Input B -shortTelegr. value (0,1)1 BitCT
8Input B -shortTelegr. value [-32768...32767]2 BytesCT
8Input B -shortTelegr. value [0...4294967295]4 BytesCT
8Input B -shortTelegr. value (temperature)2 BytesCT
8Input B -shortTelegr. value (forced position)2 BitCT
8Input B -shortTelegr. value [0...255]1 ByteCT
8Input B -shortTelegr. value [0...65535]2 BytesCT
8Input BTelegr. shutter UP/DOWN1 BitCT
8Input B -shortTelegr. switch1 BitCWT
9Input B -longTelegr. switch -long1 BitCT
9Input BDifferential counter 2 bytes2 BytesCWT
9Input BDifferential counter 1 byte1 ByteCWT
9Input BDifferential counter 4 bytes4 BytesCWT
9Input BTelegr. operation 2-fold1 BitCWT
9Input BTelegr. value 21 BitCWT
9Output BLED, flashing1 BitCW
9Input BTelegr. value actuator group B1 ByteCWTU
9Input BSwitch actuator group B1 BitCWTU
9Input B -longTelegr. value (temperature)2 BytesCT
9Input B -longTelegr. value (0,1)1 BitCT
9Input B -longTelegr. value [-32768...32767]2 BytesCT
9Input B -longTelegr. value [0...4294967295]4 BytesCT
9Input B -longTelegr. value (forced position)2 BitCT
9Input B -longTelegr. value [0...255]1 ByteCT
9Input B -longTelegr. value [0...65535]2 BytesCT
9Input BTelegr. STOP / lamella adj.1 BitCT
9Input BTelegr. dimming4 BitCT
10Output Bvalve purge1 BitCW
10Input BRequest counter values1 BitCW
10Input BTelegr. operation 3-fold1 BitCWT
10Input BTelegr. value 31 BitCWT
10Output BLED permanent ON1 BitCW
10Input BTelegr. value actuator group C1 ByteCWTU
10Input BSwitch actuator group C1 BitCWTU
10Input BUpper limit position1 BitCW
11Output BForced positioning1 BitCW
11Input BDifferential counter overflow1 BitCT
11Input BTelegr. operation 4-fold1 BitCWT
11Input BTelegr. value 41 BitCWT
11Output BTelegr. status/ackn.1 BitCT
11Input BTelegr. value actuator group D1 ByteCWTU
11Input BSwitch actuator group D1 BitCWTU
11Input BLower limit position1 BitCW
12Output BTelegr. status/ackn.1 BitCT
12Input BReset differential counter1 BitCW
12Input BTelegr. value 51 BitCWT
12Input BTelegr. value actuator group E1 ByteCWTU
12Input BSwitch actuator group E1 BitCWTU
13Output BTelegr. fault1 BitCT
13Input BTelegr. operation long1 BitCT
13Input BLevel increment/decrement1 BitCW
13Input BStore scene1 BitCWT
14Input CDisable1 BitCW
15Output CControl value (PWM)1 ByteCW
15Output CTelegr. switch1 BitCW
15Input CTelegr. switch1 BitCWT
15Input CTelegr. counter value 2 bytes2 BytesCWT
15Input CTelegr. counter value 1 byte1 ByteCWT
15Input CTelegr. counter value 4 bytes4 BytesCWT
15Input CTelegr. operation 1-fold1 BitCWT
15Input CTelegr. value 11 BitCWT
15Output CLED, switching1 BitCW
15Input CTelegr. value actuator group A1 ByteCWTU
15Input CSwitch actuator group A1 BitCWTU
15Input C8-bit-scene1 ByteCT
15Input CTelegr. value [-32768...32767]2 BytesCT
15Input CTelegr. value [0...4294967295]4 BytesCT
15Input CTelegr. value (temperature)2 BytesCT
15Input CTelegr. value (forced position)2 BitCT
15Input CTelegr. value [0...255]1 ByteCT
15Input CTelegr. value [0...65535]2 BytesCT
15Input C -shortTelegr. value (0,1)1 BitCT
15Input C -shortTelegr. value [-32768...32767]2 BytesCT
15Input C -shortTelegr. value [0...4294967295]4 BytesCT
15Input C -shortTelegr. value (temperature)2 BytesCT
15Input C -shortTelegr. value (forced position)2 BitCT
15Input C -shortTelegr. value [0...255]1 ByteCT
15Input C -shortTelegr. value [0...65535]2 BytesCT
15Input CTelegr. shutter UP/DOWN1 BitCT
15Input C -shortTelegr. switch1 BitCWT
16Input C -longTelegr. switch -long1 BitCT
16Input CDifferential counter 2 bytes2 BytesCWT
16Input CDifferential counter 1 byte1 ByteCWT
16Input CDifferential counter 4 bytes4 BytesCWT
16Input CTelegr. operation 2-fold1 BitCWT
16Input CTelegr. value 21 BitCWT
16Output CLED, flashing1 BitCW
16Input CTelegr. value actuator group B1 ByteCWTU
16Input CSwitch actuator group B1 BitCWTU
16Input C -longTelegr. value (temperature)2 BytesCT
16Input C -longTelegr. value (0,1)1 BitCT
16Input C -longTelegr. value [-32768...32767]2 BytesCT
16Input C -longTelegr. value [0...4294967295]4 BytesCT
16Input C -longTelegr. value (forced position)2 BitCT
16Input C -longTelegr. value [0...255]1 ByteCT
16Input C -longTelegr. value [0...65535]2 BytesCT
16Input CTelegr. STOP / lamella adj.1 BitCT
16Input CTelegr. dimming4 BitCT
17Output Cvalve purge1 BitCW
17Input CRequest counter values1 BitCW
17Input CTelegr. operation 3-fold1 BitCWT
17Input CTelegr. value 31 BitCWT
17Output CLED permanent ON1 BitCW
17Input CTelegr. value actuator group C1 ByteCWTU
17Input CSwitch actuator group C1 BitCWTU
17Input CUpper limit position1 BitCW
18Output CForced positioning1 BitCW
18Input CDifferential counter overflow1 BitCT
18Input CTelegr. operation 4-fold1 BitCWT
18Input CTelegr. value 41 BitCWT
18Output CTelegr. status/ackn.1 BitCT
18Input CTelegr. value actuator group D1 ByteCWTU
18Input CSwitch actuator group D1 BitCWTU
18Input CLower limit position1 BitCW
19Output CTelegr. status/ackn.1 BitCT
19Input CReset differential counter1 BitCW
19Input CTelegr. value 51 BitCWT
19Input CTelegr. value actuator group E1 ByteCWTU
19Input CSwitch actuator group E1 BitCWTU
20Output CTelegr. fault1 BitCT
20Input CTelegr. operation long1 BitCT
20Input CLevel increment/decrement1 BitCW
20Input CStore scene1 BitCWT
21Input DDisable1 BitCW
22Input DTelegr. operation 1-fold1 BitCWT
22Input DTelegr. value 11 BitCWT
22Input D -shortTelegr. switch1 BitCWT
22Input DTelegr. shutter UP/DOWN1 BitCT
22Input D -shortTelegr. value (0,1)1 BitCT
22Input D -shortTelegr. value [-32768...32767]2 BytesCT
22Input D -shortTelegr. value [0...4294967295]4 BytesCT
22Input D -shortTelegr. value (temperature)2 BytesCT
22Input D -shortTelegr. value (forced position)2 BitCT
22Input D -shortTelegr. value [0...255]1 ByteCT
22Input D -shortTelegr. value [0...65535]2 BytesCT
22Input DTelegr. value (forced position)2 BitCT
22Input DTelegr. value [0...255]1 ByteCT
22Input DTelegr. value [0...65535]2 BytesCT
22Input DTelegr. value [-32768...32767]2 BytesCT
22Input DTelegr. value [0...4294967295]4 BytesCT
22Input DTelegr. value (temperature)2 BytesCT
22Output DLED, switching1 BitCW
22Input D8-bit-scene1 ByteCT
22Input DTelegr. value actuator group A1 ByteCWTU
22Input DSwitch actuator group A1 BitCWTU
22Input DTelegr. counter value 2 bytes2 BytesCWT
22Input DTelegr. counter value 4 bytes4 BytesCWT
22Input DTelegr. counter value 1 byte1 ByteCWT
22Output DControl value (PWM)1 ByteCW
22Output DTelegr. switch1 BitCW
22Input DTelegr. switch1 BitCWT
23Input DTelegr. operation 2-fold1 BitCWT
23Input DTelegr. value 21 BitCWT
23Input DTelegr. dimming4 BitCT
23Input DTelegr. STOP / lamella adj.1 BitCT
23Input D -longTelegr. value (temperature)2 BytesCT
23Input D -longTelegr. value (0,1)1 BitCT
23Input D -longTelegr. value [-32768...32767]2 BytesCT
23Input D -longTelegr. value [0...4294967295]4 BytesCT
23Input D -longTelegr. value (forced position)2 BitCT
23Input D -longTelegr. value [0...255]1 ByteCT
23Input D -longTelegr. value [0...65535]2 BytesCT
23Output DLED, flashing1 BitCW
23Input DTelegr. value actuator group B1 ByteCWTU
23Input DSwitch actuator group B1 BitCWTU
23Input DDifferential counter 2 bytes2 BytesCWT
23Input DDifferential counter 4 bytes4 BytesCWT
23Input DDifferential counter 1 byte1 ByteCWT
23Input D -longTelegr. switch -long1 BitCT
24Input DTelegr. operation 3-fold1 BitCWT
24Input DTelegr. value 31 BitCWT
24Input DUpper limit position1 BitCW
24Output DLED permanent ON1 BitCW
24Input DTelegr. value actuator group C1 ByteCWTU
24Input DSwitch actuator group C1 BitCWTU
24Input DRequest counter values1 BitCW
24Output Dvalve purge1 BitCW
25Input DTelegr. operation 4-fold1 BitCWT
25Input DTelegr. value 41 BitCWT
25Input DLower limit position1 BitCW
25Output DTelegr. status/ackn.1 BitCT
25Input DTelegr. value actuator group D1 ByteCWTU
25Input DSwitch actuator group D1 BitCWTU
25Input DDifferential counter overflow1 BitCT
25Output DForced positioning1 BitCW
26Input DTelegr. value 51 BitCWT
26Input DTelegr. value actuator group E1 ByteCWTU
26Input DSwitch actuator group E1 BitCWTU
26Input DReset differential counter1 BitCW
26Output DTelegr. status/ackn.1 BitCT
27Input DTelegr. operation long1 BitCT
27Input DLevel increment/decrement1 BitCW
27Input DStore scene1 BitCWT
27Output DTelegr. fault1 BitCT
28Object 291 BitCRWTU
29Output telegramTelegr. trigger valve purge1 BitCT
Parameters (204)
ParameterTypeDefault
Baselist1s
Transmission delay [2...255s] after bus voltage recoveryunsignedInt 2…2552
The transmission delay time contains the initialization timelist<--- NOTE
Die min. Sendeverzögerungszeit beträgt 5 Sekunden (Initialisierungszeit)list<--- NOTE
Limit number of telegramslistno
Max. Number of transmitted telegrams within a periodunsignedInt 0…25520
Max. Number of transmitted telegrams within period of observationunsignedInt 0…25520
Period of observationsignedInt -32768…327670
Periodlist10s
Transmit object "Telegr. valve purge"listno
This parameter is relevant for the controlling of an electronic relaylist<--- NOTE
setzt Invertierung NEIN und Auswertung: AppTimer2listnormally open
Auswertung für Kanal 9 08 Ausgang (Timer2)listChannel is output
Applikation für Kanal 9 201 Ventilspülung (PWM)unsignedInt 0…255201
Applikation für Kanal 9 0 keineunsignedInt 0…255201
Transmit telegram everylist30 days
Period of valve purgelist2 min
Function of the channellistno function
Distinction between long and short operationlistno
Operating functionality of blindlist2-push-button, standard
Control telegram is received aslist1 bit (PWM or on-off-contol)
DUMMY: LED nicht invertierenunsignedInt 0…2550
** Dummy, nicht sichtbar stellt Auswertung auf AusgangunsignedInt 0…2558
Cyclic transmission of object "Telegr. switch"listno
Connected contact typelistnormally open
Pulse detection onlistclosing contact (rising edge)
Long operation: move UP/DOWN Short operation: Lamellalist<–- Note about functionality
On every operation in succession UP - STOP - DOWN - STOPlist<–- Note about functionality
On operation UP/DOWN, end of operation STOPlist<–- Note about functionality
Short operation: STOP / lamella UP/DOWN Long operation: move UP/DOWNlist<–- Note about functionality
On operation: moving, end of operation: STOPlist<–- Note about functionality
On operation: movinglist<–- Note about functionality
On operation: steppinglist<–- Note about functionality
Long operation: Lamella Short operation: Move UP/DOWNlist<–- Note about functionality
LED functionalitylistswitch ON/OFF
LED is switched ON, iflistObject "Telegr. switch" = 1
LED flashes, iflistObject "LED flashing" = 1
Dummy: Schalten nicht invertierenunsignedInt 0…2550
Dummy: Blinken nicht invertierenunsignedInt 0…2550
Reaction on closing the contact (rising edge)listON
Reaction on short operationlistON
Dimming functionalitylistDimming and switching
Data width of counterlist32-bit [-2.147.483.648 ... 2.147.483.647]
Number of objectslist3 levels
Connected valve typelistnormally closed
Max. number of operations ( = number of objects)list3-fold operation
LED is switched ON forlist1s
Control the scene vialist5 separate objects
Dummy: Kanal ist Ausgang!listUnterscheidung kurzer/langer TD
Reaction on opening the contact (falling edge)listOFF
Reaction on long operationlistOFF
Reaction on operationlistDim BRIGHTER/DARKER
Reaction on operationlist1-byte-value [0...255]
Reaction on short operationlist1-byte-value [0...255]
Counter starts at [-32.768...32.767]signedInt -32768…327670
Counter starts at [0...255]signedInt 0…2550
Counter starts at [-2.147.483.648...2.147.483.647]signedInt -2147483648…21474836470
Counter starts at [0...65535]signedInt 0…655350
Reaction on short operationlistSTOP / lamella DOWN
Type of switching sequencelistsequentially on/off (one push-button)
Transmitted value (object "Telegr. operation ..-fold")listTOGGLE
LED is switched OFF forlist1s
No. of scenelistScene no. 1
Reaction on keypresslistMoving TOGGLE (via STOP)
Reaction on operationlistMOVE DOWN
Reaction on operationlistSTOP / lamella DOWN
Telegram is repeated every ("transmission cycle time"): baselist1s
Long operation after: Baselist100ms
Reaction on long operationlistDim BRIGHTER/DARKER
Transmitted valuelistDisable forced positioning
Transmitted value [0...255]signedInt 0…2550
Transmitted value [0...65535]signedInt 0…655350
sent valuelist0
Transmitted valuelist20.00
Transmitted value [-32768...32767]signedInt -32768…327670
Transmitted value [0...4.294.967.295]unsignedInt 0…42949672950
Reaction on short operationlistMOVE DOWN
Example for switching sequence 000>001>011>115list<--- NOTE
Example for switching sequence ...>000>001>011>111>011>001>000>...list<--- NOTE
Example for switching sequence ..>000>001>011>010>110>111>101>100>..list<--- NOTE
Time limit of LED-controllistno
PWM-cycle time for continuous controllist1min
Reaction on short operationlistRecall scene
Transmit value on every operationlistno
Debounce time / min. operation timelist50ms debounce time
Reaction on end of operationlistno reaction
Reaction on long operation NONEunsignedInt 0…2550
Dimming direction after switching ONlistDARKER
Factor [1...255]unsignedInt 1…25530
Factor [2...255]unsignedInt 2…2555
Long operation afterlist0.5s
Reaction on long operationlist1-byte-value [0...255]
The debouce time must be shorter than the pulse period of the input signallist<--- NOTE
Maximum time between two operationslist0.4s
Time limit: baselist1s
Store scenelistno
Function on operationlistswitch upwards
Function on operationlistupwards/downwards
** Dummy; nicht sichtbar deaktiviert BegrenzungszeitunsignedInt 0…2550
Function on end of operationlistno reaction
Transmit object value after bus voltage recoverylistno
Number of objects for short/long operationlist1 object
Dimming modelistStart-stop-dimming
Transmit counter values after bus voltage recoverylistno
Enable object "Telegr. valve purge"listno
Time limit: factor [1...255]unsignedInt 1…25530
Additional object for long operationlistno
"Telegr. STOP/lamella adj." is repeated everylist0.4s
Object is only transmitted, if reaction on opening/closing not equal TOGGLElist<--- NOTE
Brightness change on every sent telegramlist100%
Enable additional options (factor/divider, cyclical transmission)listno
Enable additional options (factor/divider, cyclical transmission)listyes
Enable monitoring of the controller, fault message, forced positioninglistno
Transmit status via object "Telegr. status/ackn."listno
Debounce timelist50ms debounce time
Basis der zykl. Überwachung AUSunsignedInt 0…2550
Transmission cycle time: telegram is repeated everylist0.4s
Position of the valve drive on bus voltage recoverylist20%
transmitted value (object "Telegr. operation long")listTOGGLE
Factor [1...255]unsignedInt 2…2555
Transmit object value after bus voltage recoveryunsignedInt 0…655350
** Dummy, nicht sichtbar nur ON auswertenunsignedInt 0…2550
State of LED on bus voltage recoverylistOFF
Detectionlistonly rising edge
Debounce timelist50ms
A-CountersignedInt -2048…20470
Divider: number of input pulses for one counter step [1...32767]unsignedInt 1…327671
Minimum operation time: baselist1s
Control of actuator group A vialist1-bit-object
Preset value actuator group A [0...255]unsignedInt 0…2550
Preset value actuator group AlistON
Factor: One counter step changes counter value by [-32768...32767]signedInt -32768…327671
Minimum operation time: factor [1...255]unsignedInt 1…25510
Minimum operation time: factorunsignedInt 1…25510
Control of actuator group B vialist1-bit-object
Preset value actuator group B [0...255]unsignedInt 0…2550
Preset value actuator group BlistON
Transmit counter values cyclicallylistno
Control of actuator group C vialist1-bit-object
Preset value actuator group C [0...255]unsignedInt 0…2550
Preset value actuator group ClistON
Preset value for dividerunsignedInt 0…655351
Preset value for factorunsignedInt 0…655351
Control of actuator group D vialist1-bit-object
Preset value actuator group D [0...255]unsignedInt 0…2550
Preset value actuator group DlistON
Counter values are being transmitted every: Baselist1s
Control of actuator group E vialist1-bit-object
Dummy: nicht zykl. senden BasisunsignedInt 0…655350
Preset value actuator group E [0...255]unsignedInt 0…2550
Preset value actuator group ElistON
Enable differential counterlistno
Over-/underrun of differential counter at [-32.768...32.767]signedInt -32768…327671000
Over-/underrun of differential counter at [1...65.535]signedInt 0…655351000
Over-/underrun of differential counter at [-2147483648...2147483647]signedInt -2147483648…21474836471000
Over-/underrun of differential counter at [1...255]signedInt 0…25510
The overrun value must be greater than the factorlist<--- NOTE
A-Fault/Forced Operat.unsignedInt 0…2550
Monitoring of the room thermostatlistno
Cyclic monitoring time of room thermostat: baselist1s
Position of the valve drive on failure of the controllist10%
Enable object "Telegr. fault"listno
Forced positioninglistno
valve position during forced postioninglist50%
Dummy: Kanal ist Ausgang!listChannel is output
Reaction on keypresslistMoving TOGGLE
Reaction on short operationlistSTOP / lamella UP
Reaction on operationlistMOVE UP
Reaction on operationlistSTOP / lamella UP
Telegram is repeated every ("transmission cycle time"): baselist1min
Example for switching sequence 000>001>011>113list<--- NOTE
Reaction on end of operationlistLamella dir. reverse to moving (cycl.)
Reaction on short operationlistMOVE UP
Factor [1...255]unsignedInt 1…25520
Maximum time between two operationslist1s
Time limit: baselist1min
Time limit: factor [1...255]unsignedInt 1…25520
"Telegr. STOP/lamella adj." is repeated everylist1s
Transmission cycle time: telegram is repeated everylist1s
B-CountersignedInt -2048…20470
Counter values are being transmitted every: Baselist1min
Over-/underrun of differential counter at [-2147483648...2147483647]signedInt -2147483648…21474836470
B-Fault/Forced Operat.unsignedInt 0…2550
Cyclic monitoring time of room thermostat: baselist1min
Example for switching sequence 000>001>011>112list<--- NOTE
C-CountersignedInt -2048…20470
C-Fault/Forced Operat.unsignedInt 0…2550
Factor [1...255]list1min
Cyclic monitoring time of room thermostat: baseunsignedInt 1…25520
Reaction on short operationlistTOGGLE
Reaction on closing the contact (rising edge)listTOGGLE
Dummy: Kanal ist Ausgang!listStandard (only debouncing)
Example for switching sequence 000>001>011>114list<--- NOTE
Telegram is repeated every ("transmission cycle time"): baselist10s
Time limit: baselist10s
Factor [2...255]unsignedInt 2…2554
Factor [1...255]unsignedInt 1…2555
Time limit: factor [1...255]unsignedInt 1…2555
Factor [1...255]unsignedInt 2…2554
D-CountersignedInt -2048…20470
Preset value actuator group CunsignedInt 0…2550
Counter values are being transmitted every: Baselist10s
D-Fault/Forced Operat.unsignedInt 0…2550
Cyclic monitoring time of room thermostat: baselist10s

Version history

ApplicationApp noFingerprintFirst seenSizeFile
Binary Input Display Heat, 4f/1.3a 1.3 latest$A001A05E2026-11-25212 KBDownload
Binary Input Display Heat, 4f/1.3a 1.3$A001A05E2026-11-25212 KBDownload
Binary Input Display Heat, 4f/1.3a 1.3$A001A05E2026-11-25212 KBDownload

About this file

This is the official ETS product database for the ABB AG - BUSCH-JAEGER 6119/40 4f-Universalschnittstelle, UP (6119/40), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.

More from ABB AG - BUSCH-JAEGER

All ABB AG - BUSCH-JAEGER products