KNX Database

MK8380

Zhejiang Moorgen Group Co.,Ltd · Order number MK8380 · Push button › Thermostat

Download .knxprod Rotary thermostate panel 1.0 · 156 KB

Product

ManufacturerZhejiang Moorgen Group Co.,Ltd
Product nameMK8380
Order numberMK8380
Product textRotary thermostate panel
HardwareRotary thermostate panel
MediumTwisted Pair
Bus current (mA)12
Rail mountedNo
RegistrationRegistered · 2026-05-20
Languagesen-US
Catalog entryM-028D_H-CH24CE-1_HP-F068-10-BBF2_CI-MK8380-1
FingerprintBBF2
SHA-25623eb9e04afd4db979eb7e2cf7b5953d632462385054270965c798e466bd08499
First seen2026-11-25
Markets69 markets

Application program: Rotary thermostate panel 1.0

Application number$F068
Version1.0
Mask versionMV-07B0 (System B)
KNX Data SecureNo
Minimum ETS version5.0
Parameters345
Group objects238
Group objects (238)
NoNameFunctionSizeDPTFlags
0FCU 1Power on/off1 Bit1.1 switchCWU
0FCU 1Power on/off, status1 Bit1.1 switchCWTU
0VRF 1Power on/off, status1 Bit1.1 switchCWTU
0FCU 2Power on/off1 Bit1.1 switchCWU
0FCU 2Power on/off, status1 Bit1.1 switchCWTU
0VRF 2Power on/off, status1 Bit1.1 switchCWTU
0FCU 3Power on/off1 Bit1.1 switchCWU
0FCU 3Power on/off, status1 Bit1.1 switchCWTU
0VRF 3Power on/off, status1 Bit1.1 switchCWTU
1Internal sensorActual temperature2 Bytes9.1 temperature (°C)CRT
1FCU 1External temperature sensor2 Bytes9.1 temperature (°C)CWTU
1VRF 1External temperature sensor2 Bytes9.1 temperature (°C)CWTU
1FCU 2External temperature sensor2 Bytes9.1 temperature (°C)CWTU
1VRF 2External temperature sensor2 Bytes9.1 temperature (°C)CWTU
1FCU 3External temperature sensor2 Bytes9.1 temperature (°C)CWTU
1VRF 3External temperature sensor2 Bytes9.1 temperature (°C)CWTU
2Internal sensorLow temperature alarm1 Bit1.5 alarmCRT
2FCU 1Current temperature setpoint2 Bytes9.1 temperature (°C)CWU
2FCU 1Current temperature setpoint, status2 Bytes9.1 temperature (°C)CWTU
2FCU 1Base temperature setpoint2 Bytes9.1 temperature (°C)CWU
2VRF 1Current temperature setpoint, status2 Bytes9.1 temperature (°C)CWTU
2FCU 2Current temperature setpoint2 Bytes9.1 temperature (°C)CWU
2FCU 2Current temperature setpoint, status2 Bytes9.1 temperature (°C)CWTU
2FCU 2Base temperature setpoint2 Bytes9.1 temperature (°C)CWU
2VRF 2Current temperature setpoint, status2 Bytes9.1 temperature (°C)CWTU
2FCU 3Current temperature setpoint2 Bytes9.1 temperature (°C)CWU
2FCU 3Current temperature setpoint, status2 Bytes9.1 temperature (°C)CWTU
2FCU 3Base temperature setpoint2 Bytes9.1 temperature (°C)CWU
2VRF 3Current temperature setpoint, status2 Bytes9.1 temperature (°C)CWTU
3Internal sensorHigh temperature alarm1 Bit1.5 alarmCRT
3FCU 1Heating/Cooling mode1 Bit1.100 cooling/heatingCWU
3FCU 1Heating/Cooling mode, status1 Bit1.100 cooling/heatingCWTU
3VRF 1Control mode, status1 Byte20.105 HVAC control modeCWTU
3FCU 2Heating/Cooling mode1 Bit1.100 cooling/heatingCWU
3FCU 2Heating/Cooling mode, status1 Bit1.100 cooling/heatingCWTU
3VRF 2Control mode, status1 Byte20.105 HVAC control modeCWTU
3FCU 3Heating/Cooling mode1 Bit1.100 cooling/heatingCWU
3FCU 3Heating/Cooling mode, status1 Bit1.100 cooling/heatingCWTU
3VRF 3Control mode, status1 Byte20.105 HVAC control modeCWTU
4FCU 1Operation mode, status1 Byte20.102 HVAC modeCWTU
4FCU 1Operation mode1 Byte20.102 HVAC modeCWU
4VRF 1Fan speed, status1 Byte5.1 percentage (0..100%)CWTU
4VRF 1Fan speed, status1 Byte5.100 fan stage (0..255)CWTU
4FCU 2Operation mode, status1 Byte20.102 HVAC modeCWTU
4FCU 2Operation mode1 Byte20.102 HVAC modeCWU
4VRF 2Fan speed, status1 Byte5.1 percentage (0..100%)CWTU
4VRF 2Fan speed, status1 Byte5.100 fan stage (0..255)CWTU
4FCU 3Operation mode, status1 Byte20.102 HVAC modeCWTU
4FCU 3Operation mode1 Byte20.102 HVAC modeCWU
4VRF 3Fan speed, status1 Byte5.1 percentage (0..100%)CWTU
4VRF 3Fan speed, status1 Byte5.100 fan stage (0..255)CWTU
5FCU 1Fan speed, status1 Byte5.1 percentage (0..100%)CWTU
5FCU 1Fan speed, status1 Byte5.100 fan stage (0..255)CWTU
5VRF 1Vanes swing of up/down, status1 Bit1.10 start/stopCWTU
5FCU 2Fan speed, status1 Byte5.1 percentage (0..100%)CWTU
5FCU 2Fan speed, status1 Byte5.100 fan stage (0..255)CWTU
5VRF 2Vanes swing of up/down, status1 Bit1.10 start/stopCWTU
5FCU 3Fan speed, status1 Byte5.1 percentage (0..100%)CWTU
5FCU 3Fan speed, status1 Byte5.100 fan stage (0..255)CWTU
5VRF 3Vanes swing of up/down, status1 Bit1.10 start/stopCWTU
6FCU 1Fan Automatic operation, status1 Bit1.3 enableCWTU
6VRF 1Vanes swing of left/right, status1 Bit1.10 start/stopCWTU
6FCU 2Fan Automatic operation, status1 Bit1.3 enableCWTU
6VRF 2Vanes swing of left/right, status1 Bit1.10 start/stopCWTU
6FCU 3Fan Automatic operation, status1 Bit1.3 enableCWTU
6VRF 3Vanes swing of left/right, status1 Bit1.10 start/stopCWTU
7FCU 1Extended comfort mode1 Bit1.16 acknowledgeCW
7VRF 1Timer1 Bit1.3 enableCW
7FCU 2Extended comfort mode1 Bit1.16 acknowledgeCW
7VRF 2Timer1 Bit1.3 enableCW
7FCU 3Extended comfort mode1 Bit1.16 acknowledgeCW
7VRF 3Timer1 Bit1.3 enableCW
8FCU 1Window contact1 Bit1.19 window/doorCWTU
8VRF 1Scene1 Byte18.1 scene controlCW
8FCU 2Window contact1 Bit1.19 window/doorCWTU
8VRF 2Scene1 Byte18.1 scene controlCW
8FCU 3Window contact1 Bit1.19 window/doorCWTU
8VRF 3Scene1 Byte18.1 scene controlCW
9FCU 1Presence detector1 Bit1.18 occupancyCWTU
9VRF 1Power on/off1 Bit1.1 switchCT
9FCU 2Presence detector1 Bit1.18 occupancyCWTU
9VRF 2Power on/off1 Bit1.1 switchCT
9FCU 3Presence detector1 Bit1.18 occupancyCWTU
9VRF 3Power on/off1 Bit1.1 switchCT
10FCU 1Timer1 Bit1.3 enableCW
10VRF 1Current setpoint adjustment2 Bytes9.1 temperature (°C)CT
10FCU 2Timer1 Bit1.3 enableCW
10VRF 2Current setpoint adjustment2 Bytes9.1 temperature (°C)CT
10FCU 3Timer1 Bit1.3 enableCW
10VRF 3Current setpoint adjustment2 Bytes9.1 temperature (°C)CT
11FCU 1Scene1 Byte18.1 scene controlCW
11VRF 1Fan speed1 Byte5.1 percentage (0..100%)CT
11VRF 1Fan speed1 Byte5.100 fan stage (0..255)CT
11FCU 2Scene1 Byte18.1 scene controlCW
11VRF 2Fan speed1 Byte5.1 percentage (0..100%)CT
11VRF 2Fan speed1 Byte5.100 fan stage (0..255)CT
11FCU 3Scene1 Byte18.1 scene controlCW
11VRF 3Fan speed1 Byte5.1 percentage (0..100%)CT
11VRF 3Fan speed1 Byte5.100 fan stage (0..255)CT
12FCU 1Power on/off, status1 Bit1.1 switchCRT
12FCU 1Power on/off1 Bit1.1 switchCT
12VRF 1Vanes swing of up/down1 Bit1.10 start/stopCT
12FCU 2Power on/off, status1 Bit1.1 switchCRT
12FCU 2Power on/off1 Bit1.1 switchCT
12VRF 2Vanes swing of up/down1 Bit1.10 start/stopCT
12FCU 3Power on/off, status1 Bit1.1 switchCRT
12FCU 3Power on/off1 Bit1.1 switchCT
12VRF 3Vanes swing of up/down1 Bit1.10 start/stopCT
13FCU 1Actual temperature2 Bytes9.1 temperature (°C)CRT
13VRF 1Vanes swing of left/right1 Bit1.10 start/stopCT
13FCU 2Actual temperature2 Bytes9.1 temperature (°C)CRT
13VRF 2Vanes swing of left/right1 Bit1.10 start/stopCT
13FCU 3Actual temperature2 Bytes9.1 temperature (°C)CRT
13VRF 3Vanes swing of left/right1 Bit1.10 start/stopCT
14FCU 1Current base temperature setpoint, status2 Bytes9.1 temperature (°C)CRT
14VRF 1Control mode1 Byte20.105 HVAC control modeCT
14FCU 2Current base temperature setpoint, status2 Bytes9.1 temperature (°C)CRT
14VRF 2Control mode1 Byte20.105 HVAC control modeCT
14FCU 3Current base temperature setpoint, status2 Bytes9.1 temperature (°C)CRT
14VRF 3Control mode1 Byte20.105 HVAC control modeCT
15FCU 1Current temperature setpoint adjustment, status2 Bytes9.1 temperature (°C)CRT
15FCU 1Current temperature setpoint adjustment2 Bytes9.1 temperature (°C)CT
15FCU 2Current temperature setpoint adjustment, status2 Bytes9.1 temperature (°C)CRT
15FCU 2Current temperature setpoint adjustment2 Bytes9.1 temperature (°C)CT
15FCU 3Current temperature setpoint adjustment, status2 Bytes9.1 temperature (°C)CRT
15FCU 3Current temperature setpoint adjustment2 Bytes9.1 temperature (°C)CT
16FCU 1Heating/Cooling mode1 Bit1.100 cooling/heatingCT
16FCU 1Heating/Cooling mode, status1 Bit1.100 cooling/heatingCRT
16FCU 2Heating/Cooling mode1 Bit1.100 cooling/heatingCT
16FCU 2Heating/Cooling mode, status1 Bit1.100 cooling/heatingCRT
16FCU 3Heating/Cooling mode1 Bit1.100 cooling/heatingCT
16FCU 3Heating/Cooling mode, status1 Bit1.100 cooling/heatingCRT
17FCU 1Operation mode1 Byte20.102 HVAC modeCT
17FCU 1Operation mode, status1 Byte20.102 HVAC modeCRT
17FCU 2Operation mode1 Byte20.102 HVAC modeCT
17FCU 2Operation mode, status1 Byte20.102 HVAC modeCRT
17FCU 3Operation mode1 Byte20.102 HVAC modeCT
17FCU 3Operation mode, status1 Byte20.102 HVAC modeCRT
18FCU 1Heating control value1 Bit1.1 switchCRT
18FCU 1Heating control value1 Byte5.1 percentage (0..100%)CRT
18FCU 1Heating/Cooling control value1 Bit1.1 switchCRT
18FCU 1Heating/cooling control value1 Byte5.1 percentage (0..100%)CRT
18FCU 2Heating control value1 Bit1.1 switchCRT
18FCU 2Heating control value1 Byte5.1 percentage (0..100%)CRT
18FCU 2Heating/Cooling control value1 Bit1.1 switchCRT
18FCU 2Heating/cooling control value1 Byte5.1 percentage (0..100%)CRT
18FCU 3Heating control value1 Bit1.1 switchCRT
18FCU 3Heating control value1 Byte5.1 percentage (0..100%)CRT
18FCU 3Heating/Cooling control value1 Bit1.1 switchCRT
18FCU 3Heating/cooling control value1 Byte5.1 percentage (0..100%)CRT
19FCU 1Cooling control value1 Bit1.1 switchCRT
19FCU 1Cooling control value1 Byte5.1 percentage (0..100%)CRT
19FCU 2Cooling control value1 Bit1.1 switchCRT
19FCU 2Cooling control value1 Byte5.1 percentage (0..100%)CRT
19FCU 3Cooling control value1 Bit1.1 switchCRT
19FCU 3Cooling control value1 Byte5.1 percentage (0..100%)CRT
20FCU 1Fan speed1 Byte5.1 percentage (0..100%)CT
20FCU 1Fan speed1 Byte5.1 percentage (0..100%)CRT
20FCU 1Fan speed1 Byte5.100 fan stage (0..255)CT
20FCU 1Fan speed1 Byte5.100 fan stage (0..255)CRT
20FCU 2Fan speed1 Byte5.1 percentage (0..100%)CT
20FCU 2Fan speed1 Byte5.1 percentage (0..100%)CRT
20FCU 2Fan speed1 Byte5.100 fan stage (0..255)CT
20FCU 2Fan speed1 Byte5.100 fan stage (0..255)CRT
20FCU 3Fan speed1 Byte5.1 percentage (0..100%)CT
20FCU 3Fan speed1 Byte5.1 percentage (0..100%)CRT
20FCU 3Fan speed1 Byte5.100 fan stage (0..255)CT
20FCU 3Fan speed1 Byte5.100 fan stage (0..255)CRT
21FCU 1Fan Automatic operation1 Bit1.3 enableCT
21FCU 1Fan Automatic operation1 Bit1.3 enableCRT
21FCU 2Fan Automatic operation1 Bit1.3 enableCT
21FCU 2Fan Automatic operation1 Bit1.3 enableCRT
21FCU 3Fan Automatic operation1 Bit1.3 enableCT
21FCU 3Fan Automatic operation1 Bit1.3 enableCRT
115Floor heatingPower on/off1 Bit1.1 switchCWU
115Floor heatingPower on/off, status1 Bit1.1 switchCWTU
116Floor heatingExternal temperature sensor2 Bytes9.1 temperature (°C)CWTU
117Floor heatingCurrent temperature setpoint2 Bytes9.1 temperature (°C)CWU
117Floor heatingCurrent temperature setpoint, status2 Bytes9.1 temperature (°C)CWTU
118Floor heatingTimer1 Bit1.3 enableCW
119Floor heatingScene1 Byte18.1 scene controlCW
120Floor heatingPower on/off, status1 Bit1.1 switchCRT
120Floor heatingPower on/off1 Bit1.1 switchCT
121Floor heatingActual temperature2 Bytes9.1 temperature (°C)CRT
122Floor heatingCurrent temperature setpoint adjustment, status2 Bytes9.1 temperature (°C)CRT
122Floor heatingCurrent setpoint adjustment2 Bytes9.1 temperature (°C)CT
123Floor heatingHeating on/off1 Bit1.1 switchCRT
123Floor heatingHeating control value1 Byte5.1 percentage (0..100%)CRT
124VentilationPower on/off, status1 Bit1.1 switchCW
125VentilationFan speed, status1 Byte5.1 percentage (0..100%)CW
125VentilationFan speed, status1 Byte5.100 fan stage (0..255)CW
126VentilationFan automatic operation, status1 Bit1.3 enableCW
127VentilationHeat recovery on/off, status1 Bit1.1 switchCW
128VentilationEn./Dis. Heat recovery1 Bit1.3 enableCW
129VentilationFilter timer counter change2 Bytes7.7 time (h)CW
130VentilationFilter timer reset, status1 Bit1.15 resetCW
131VentilationTimer1 Bit1.3 enableCW
132VentilationScene1 Byte18.1 scene controlCW
133VentilationCO2 value2 Bytes9.8 parts/million (ppm)CWTU
134VentilationPM2.5 value2 Bytes9.30 concentration (µg/m³)CWTU
135VentilationVOC value2 Bytes9.30 concentration (µg/m³)CWTU
136VentilationPower on/off1 Bit1.1 switchCT
137VentilationFan speed1 Byte5.1 percentage (0..100%)CT
137VentilationFan speed1 Byte5.100 fan stage (0..255)CT
138VentilationFan automatic operation1 Bit1.3 enableCT
139VentilationHeat recovery on/off1 Bit1.1 switchCT
140VentilationFilter timer counter2 Bytes7.7 time (h)CT
141VentilationFilter alarm1 Bit1.5 alarmCT
142VentilationFilter timer reset1 Bit1.15 resetCT
143OutputFan speed on/off, status1 Bit1.1 switchCRT
144OutputFan speed, status1 Byte5.100 fan stage (0..255)CRT
144OutputFan speed, status1 Byte5.1 percentage (0..100%)CRT
145OutputFan speed 1, status1 Bit1.1 switchCRT
146OutputFan speed 2, status1 Bit1.1 switchCRT
147OutputFan speed 3, status1 Bit1.1 switchCRT
148OutputFan speed1 Byte5.100 fan stage (0..255)CW
148OutputFan speed1 Byte5.1 percentage (0..100%)CW
149OutputFan speed 11 Bit1.1 switchCW
150OutputFan speed 21 Bit1.1 switchCW
151OutputFan speed 31 Bit1.1 switchCW
152OutputValve status, Heating1 Bit1.1 switchCRT
152OutputValve status, Floor Heating1 Bit1.1 switchCRT
152OutputValve status1 Bit1.1 switchCRT
153OutputValve status, Cooling1 Bit1.1 switchCRT
153OutputValve status, 2pipe1 Bit1.1 switchCRT
154OutputControl value, Heating1 Bit1.1 switchCW
154OutputControl value, Floor Heating1 Bit1.1 switchCW
154OutputControl value1 Bit1.1 switchCW
155OutputControl value, Cooling1 Bit1.1 switchCW
155OutputControl value, 2pipe1 Bit1.1 switchCW
156GeneralIn operation1 Bit1.1 switchCRT
157GeneralDis/En Proximity function1 Bit1.3 enableCW
158GeneralProximity input1 Bit1.1 switchCW
159GeneralProximity output, 1bit value1 Bit1.1 switchCT
159GeneralProximity output, scene NO.1 Byte17.1 scene numberCT
159GeneralProximity output, 1byte value1 Byte5.10 counter pulses (0..255)CT
159GeneralProximity output, 1byte value1 Byte5.1 percentage (0..100%)CT
160GeneralAmbience light1 Byte5.1 percentage (0..100%)CWT
Parameters (241)
ParameterTypeDefault
Send delay after voltage recovery [0..15]unsignedInt 0…155
Send cycle of "In operation" telegram [1..240,0=inactive]unsignedInt 0…2400
The Proximity function triggered vialistSensor
Sensor sensitivitylistMedium
Object type of output valuelist1bit[On/Off]
Reaction for proximity approachinglistSend a value
Output value [On/Off]listON
Output scene NO.[1..64]listScene No.1
Output value [0..255]unsignedInt 0…255255
Output value [0..100]unsignedInt 0…100100
Delay time for sending [0..65535]unsignedInt 0…655350
Reaction for proximity leavinglistNo action
Output value [On/Off]listOFF
Output scene NO.[1..64]listScene No.2
Output value [0..255]unsignedInt 0…2550
Output value [0..100]unsignedInt 0…1000
Delay time for sending [5..65535]unsignedInt 5…6553510
Flashing duration in operationunsignedInt 0…51
Flashing frequency in operationunsignedInt 0…5010
Screen brightness settinglistControl by proximity sensor
Brightness value in normal modeunsignedInt 0…100100
Ambience lightlistControl by proximity sensor
Ambience lightlistDisable
Brightness for ambience lightunsignedInt 0…100100
General time for screen turn off &ambience light turn on/off (from 0 to 100%/from 100% to 0)unsignedInt 1…105
Delay for screen turn off&ambience light turn on after proximity leavingunsignedInt 0…25560
Brightness valueunsignedInt 0…100100
Delay time for normal to standby [0..255, 0=inactive]unsignedInt 0…25510
Brightness value in standby mode [0..50]unsignedInt 0…5010
Delay time for exiting setting status [3..15]unsignedInt 3…155
Temperature display unitlistCelsius(°C)
Temperature calibrationlist0.0
Send temperature when the result change bylist1.0K
Cyclically send temperature [0..255,0=inactive]unsignedInt 0…25510
Send alarm telegram for low/high temperaturelistNo respond
Threshold value for low temperature alarmlist0
Threshold value for high temperature alarmlist45
Room temperature control function 1 aslistDisable
Floor heating functionunsignedInt 0…10
Ventilation functionunsignedInt 0…10
Setpoint Temperature errorunsignedInt 0…10
Work modelistMaster
Room temperature reference fromlistInternal sensor
Period for request external sensor [0..255]unsignedInt 0…2555
Combination ratiolist50% Internal to 50% External
Cyclically send temperature [0...255,0=inactive]unsignedInt 0…2550
Control value after temp. error [0..100] (If 2-point control, set value '0'=0, set value '>0'=1)unsignedInt 0…1000
Interface display temperaturelistActual temperature
The interval for displayed temperature alternatelylist10
Setpoint temperature adjustment steplist0.5K
Default setpoint temperature [5..40]list20
Min. setpoint temperature [5..40]list16
Max. setpoint temperature [5..40]list32
Power on/off status after downloadlistON
Power on/off status after voltage recoverylistAs before voltage failure
Temperature control methodlistHeating on/off (2 point control)
Object value of Heating on/offlistHeat on=1, Heat off=0
Lower Hysteresis [0..200]unsignedInt 0…20010
Upper Hysteresis [0..200]unsignedInt 0…20010
Invert control valueunsignedInt 0…10
PWM cycle time [1..255]unsignedInt 1…25515
Heating speedlistUnderfloor heating(5K/240min)
Proportional range [10..100]unsignedInt 10…10040
Reset time [0..255]unsignedInt 0…255150
Send control value on change by [0..100,0=inactive]unsignedInt 0…1004
Cyclically send heating control value [0..255]unsignedInt 0…2550
TimerunsignedInt 0…10
SceneunsignedInt 0…10
1->Assign scene NO.[1..64,0=inactive]unsignedInt 0…640
ON/OFFlistUnchange
TemperaturelistUnchange
2->Assign scene NO.[1..64,0=inactive]unsignedInt 0…640
3->Assign scene NO.[1..64,0=inactive]unsignedInt 0…640
4->Assign scene NO.[1..64,0=inactive]unsignedInt 0…640
5->Assign scene NO.[1..64,0=inactive]unsignedInt 0…640
Fan speed levellist3
Power on/off status after downloadlistOFF
Default fan speed after ventilation onlistFan speed 1
Object datatype of 1byte fan speedlistPercentage (DPT_5.001)
Output value for Fan speed 1unsignedInt 1…10033
Output value for Fan speed 2unsignedInt 1…10067
Output value for Fan speed 3unsignedInt 1…100100
Status value for Fan speed 1unsignedInt 1…10033
Status value for Fan speed 2unsignedInt 1…10067
Status value for Fan speed 3unsignedInt 1…100100
Output value for Fan speed 1unsignedInt 1…2551
Output value for Fan speed 2unsignedInt 1…2552
Output value for Fan speed 3unsignedInt 1…2553
Status value for Fan speed 1unsignedInt 1…2551
Status value for Fan speed 2unsignedInt 1…2552
Status value for Fan speed 3unsignedInt 1…2553
Automatic operation functionunsignedInt 0…10
Control value reference fromlistCO2
Object datatype of CO2listFloat value in ppm(DPT_9.008)
Object datatype of PM2.5listFloat value in ug/m3(DPT_9.030)
Object datatype of VOClistFloat value in ug/m3(DPT_9.030)
Period for request control value [0..255]unsignedInt 0…25510
The speed status after control value errorlistOFF
Threshold value speed OFF<->1 [1..4000]unsignedInt 1…4000400
Threshold value speed 1<->2 [1..4000]unsignedInt 1…4000800
Threshold value speed 2<->3 [1..4000]unsignedInt 1…40001200
Hysteresis value is threshold value in +/-[100..400]unsignedInt 100…400200
Threshold value speed OFF<->1 [1..999]unsignedInt 1…99935
Threshold value speed 1<->2 [1..999]unsignedInt 1…99975
Threshold value speed 2<->3 [1..999]unsignedInt 1…999115
Hysteresis value is threshold value in +/-[10..30]unsignedInt 10…3010
Minimum time in fan speed [0..65535]unsignedInt 0…6553510
Heat Recovery functionunsignedInt 0…10
Filter timer counterunsignedInt 0…10
Evaluation time [100..10000]unsignedInt 100…100001000
Fan levellistUnchange
Heat RecoverylistUnchange
Room temperature control function 2 aslistDisable
Room temperature control function 3 aslistDisable
Outputs 1~3 config aslistDisable
When bus recovery, fan speed islistFan speed 1
Fan operation modelistChangeover switch
Delay between fan speed switchlist400ms
Output value for fan speed 1unsignedInt 1…2551
Output value for fan speed 2unsignedInt 1…2552
Output value for fan speed 3unsignedInt 1…2553
Status value for fan speed 1unsignedInt 1…2551
Status value for fan speed 2unsignedInt 1…2552
Status value for fan speed 3unsignedInt 1…2553
Outputs 4~5 config aslistDisable
When power recovery, valve status for Heating control islistValve open
When power recovery, valve status for Cooling control islistValve open
When power recovery, valve status for Floor Heating islistValve open
When power recovery, valve status for Valve control(2pipe) islistValve open
When power recovery, valve status islistValve open
Delay between valve switchlist400ms
Output value for fan speed 1unsignedInt 1…10033
Output value for fan speed 2unsignedInt 1…10067
Output value for fan speed 3unsignedInt 1…100100
Status value for fan speed 1unsignedInt 1…10033
Status value for fan speed 2unsignedInt 1…10067
Status value for fan speed 3unsignedInt 1…100100
Function of button 1listFan speed
Function of button 2listFunction page
Function of button 3listPower on/off
Function of button 4listControl mode
Long operation for button after [3..25]unsignedInt 3…2510
Min. setpoint temperature [5..37]list5
Max. setpoint temperature [5..37]list37
Room temperature control modelistHeating
Room temperature operation modeunsignedInt 0…11
Initial setpoint temperaturelist20.0
Setpoint Temperature error min/initialunsignedInt 0…10
Setpoint Temperature error max/initialunsignedInt 0…10
Controller status after downloadlistStandby mode
Controller status after voltage recoverylistAs before voltage failure
Extended comfort mode [0..255,0=inactive]unsignedInt 0…2550
Setpoint method for operating modelistAbsolute
Base setpoint temperaturelist20.0
Setpoint Temperature error min/relative baseunsignedInt 0…10
Setpoint Temperature error max/relative baseunsignedInt 0…10
Reduced heating in standby mode [0..10]list2
Reduced heating in economy mode [0..10]list4
Setpoint temperature in frost protection [5..10]list7
Setpoint temperature in comfort mode [5..37]list21
Setpoint temperature in standby mode [5..37]list19
Setpoint temperature in economy mode [5..37]list17
Setpoint Temperature error min/heat absoluteunsignedInt 0…10
Setpoint Temperature error max/heat absoluteunsignedInt 0…10
Type of heating controllistSwitching on/off(use 2-point control)
Heating speedlistHot water heating(5K/150min)
Cyclically send control value[0..255]unsignedInt 0…2550
Increased cooling in standby mode [0..10]list2
Increased cooling in economy mode[0..10]list4
Setpoint temperature in heat protection[30..37]list35
Setpoint temperature in comfort mode [5..37]list23
Setpoint temperature in standby mode [5..37]list25
Setpoint temperature in economy mode[5..37]list27
Setpoint temperature in heat protection [30..37]list35
Setpoint Temperature error min/cool absoluteunsignedInt 0…10
Setpoint Temperature error max/cool absoluteunsignedInt 0…10
Type of cooling controllistSwitching on/off(use 2-point control)
Cooling speedlistCooling ceiling(5K/240min)
Heating/Cooling switchoverlistOnly via object
Heating/Cooling status after downloadlistCooling
Heating/Cooling status after voltage recoverylistAs before voltage failure
Room temperature control systemlist4 pipes system
Upper dead zonelist2.0
Lower dead zonelist2.0
Minimum zone between heating and cooling setpointlist2.0
Setpoint Temperature error min/HC absoluteunsignedInt 0…10
Setpoint Temperature error max/HC absoluteunsignedInt 0…10
Type of heating/cooling controllistSwitching on/off(use 2-point control)
Window contact input functionunsignedInt 0…10
Delay for window contact [0..65535]unsignedInt 0…6553515
Operation mode for open windowlistEconomy mode
Bus presence detector functionunsignedInt 0…10
FanunsignedInt 0…10
Automatic operation functionlistDisable
Threshold value speed OFF<->1 [1..255]unsignedInt 1…25580
Threshold value speed 1<->2 [1..255]unsignedInt 1…255150
Threshold value speed 2<->3 [1..255]unsignedInt 1…255200
Hysteresis threshold value in +/-[0..50]unsignedInt 0…5010
Temperature difference speed OFF<->1 [1..200]unsignedInt 1…20020
Temperature difference speed 1<->2 [1..200]unsignedInt 1…20030
Temperature difference speed 2<->3 [1..200]unsignedInt 1…20040
Hysteresis temperature difference in [0..50]unsignedInt 0…5010
Minimum time in fan speed [0..65535]unsignedInt 0…6553560
Operation modelistUnchange
Period for request external sensor [0...255]unsignedInt 0…25510
Object datatype of setpointlistFloat value in °C(DPT_9.001)
Setpoint temperature adjustment steplist1K
Min. setpoint temperature [16..32]list16
Max. setpoint temperature [16..32]list32
Vanes swingunsignedInt 0…10
Send delay between telegramslist100ms
Heating modeunsignedInt 0…11
Output value for HeatingunsignedInt 0…2551
Status value for HeatingunsignedInt 0…2551
Cooling modeunsignedInt 0…11
Output value for CoolingunsignedInt 0…2553
Status value for CoolingunsignedInt 0…2553
Fan modeunsignedInt 0…11
Output value for FanunsignedInt 0…2559
Status value for FanunsignedInt 0…2559
Dehumidification modeunsignedInt 0…11
Output value for DehumidificationunsignedInt 0…25514
Status value for DehumidificationunsignedInt 0…25514
Output value for Fan speed autounsignedInt 0…1000
Output value for Fan speed 1unsignedInt 0…10033
Output value for Fan speed 2unsignedInt 0…10067
Output value for Fan speed 3unsignedInt 0…100100
Status value for Fan speed autounsignedInt 0…1000
Status value for Fan speed 1unsignedInt 0…10033
Status value for Fan speed 2unsignedInt 0…10067
Status value for Fan speed 3unsignedInt 0…100100
Output value for Fan speed autounsignedInt 0…2550
Output value for Fan speed 1unsignedInt 0…2551
Output value for Fan speed 2unsignedInt 0…2552
Output value for Fan speed 3unsignedInt 0…2553
Status value for Fan speed autounsignedInt 0…2550
Status value for Fan speed 1unsignedInt 0…2551
Status value for Fan speed 2unsignedInt 0…2552
Status value for Fan speed 3unsignedInt 0…2553
ModelistUnchange
FanlistUnchange

Version history

ApplicationApp noFingerprintFirst seenSizeFile
Rotary thermostate panel 1.0 latest$F068BBF22026-11-25156 KBDownload

About this file

This is the official ETS product database for the Zhejiang Moorgen Group Co.,Ltd MK8380 (MK8380), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.