MK8380
Zhejiang Moorgen Group Co.,Ltd · Order number MK8380 · Push button › Thermostat
Download .knxprod Rotary thermostate panel 1.0 · 156 KB
Product
| Manufacturer | Zhejiang Moorgen Group Co.,Ltd |
|---|---|
| Product name | MK8380 |
| Order number | MK8380 |
| Product text | Rotary thermostate panel |
| Hardware | Rotary thermostate panel |
| Medium | Twisted Pair |
| Bus current (mA) | 12 |
| Rail mounted | No |
| Registration | Registered · 2026-05-20 |
| Languages | en-US |
| Catalog entry | M-028D_H-CH24CE-1_HP-F068-10-BBF2_CI-MK8380-1 |
| Fingerprint | BBF2 |
| SHA-256 | 23eb9e04afd4db979eb7e2cf7b5953d632462385054270965c798e466bd08499 |
| First seen | 2026-11-25 |
| Markets | 69 markets |
Application program: Rotary thermostate panel 1.0
| Application number | $F068 |
|---|---|
| Version | 1.0 |
| Mask version | MV-07B0 (System B) |
| KNX Data Secure | No |
| Minimum ETS version | 5.0 |
| Parameters | 345 |
| Group objects | 238 |
Group objects (238)
| No | Name | Function | Size | DPT | Flags |
|---|---|---|---|---|---|
| 0 | FCU 1 | Power on/off | 1 Bit | 1.1 switch | CWU |
| 0 | FCU 1 | Power on/off, status | 1 Bit | 1.1 switch | CWTU |
| 0 | VRF 1 | Power on/off, status | 1 Bit | 1.1 switch | CWTU |
| 0 | FCU 2 | Power on/off | 1 Bit | 1.1 switch | CWU |
| 0 | FCU 2 | Power on/off, status | 1 Bit | 1.1 switch | CWTU |
| 0 | VRF 2 | Power on/off, status | 1 Bit | 1.1 switch | CWTU |
| 0 | FCU 3 | Power on/off | 1 Bit | 1.1 switch | CWU |
| 0 | FCU 3 | Power on/off, status | 1 Bit | 1.1 switch | CWTU |
| 0 | VRF 3 | Power on/off, status | 1 Bit | 1.1 switch | CWTU |
| 1 | Internal sensor | Actual temperature | 2 Bytes | 9.1 temperature (°C) | CRT |
| 1 | FCU 1 | External temperature sensor | 2 Bytes | 9.1 temperature (°C) | CWTU |
| 1 | VRF 1 | External temperature sensor | 2 Bytes | 9.1 temperature (°C) | CWTU |
| 1 | FCU 2 | External temperature sensor | 2 Bytes | 9.1 temperature (°C) | CWTU |
| 1 | VRF 2 | External temperature sensor | 2 Bytes | 9.1 temperature (°C) | CWTU |
| 1 | FCU 3 | External temperature sensor | 2 Bytes | 9.1 temperature (°C) | CWTU |
| 1 | VRF 3 | External temperature sensor | 2 Bytes | 9.1 temperature (°C) | CWTU |
| 2 | Internal sensor | Low temperature alarm | 1 Bit | 1.5 alarm | CRT |
| 2 | FCU 1 | Current temperature setpoint | 2 Bytes | 9.1 temperature (°C) | CWU |
| 2 | FCU 1 | Current temperature setpoint, status | 2 Bytes | 9.1 temperature (°C) | CWTU |
| 2 | FCU 1 | Base temperature setpoint | 2 Bytes | 9.1 temperature (°C) | CWU |
| 2 | VRF 1 | Current temperature setpoint, status | 2 Bytes | 9.1 temperature (°C) | CWTU |
| 2 | FCU 2 | Current temperature setpoint | 2 Bytes | 9.1 temperature (°C) | CWU |
| 2 | FCU 2 | Current temperature setpoint, status | 2 Bytes | 9.1 temperature (°C) | CWTU |
| 2 | FCU 2 | Base temperature setpoint | 2 Bytes | 9.1 temperature (°C) | CWU |
| 2 | VRF 2 | Current temperature setpoint, status | 2 Bytes | 9.1 temperature (°C) | CWTU |
| 2 | FCU 3 | Current temperature setpoint | 2 Bytes | 9.1 temperature (°C) | CWU |
| 2 | FCU 3 | Current temperature setpoint, status | 2 Bytes | 9.1 temperature (°C) | CWTU |
| 2 | FCU 3 | Base temperature setpoint | 2 Bytes | 9.1 temperature (°C) | CWU |
| 2 | VRF 3 | Current temperature setpoint, status | 2 Bytes | 9.1 temperature (°C) | CWTU |
| 3 | Internal sensor | High temperature alarm | 1 Bit | 1.5 alarm | CRT |
| 3 | FCU 1 | Heating/Cooling mode | 1 Bit | 1.100 cooling/heating | CWU |
| 3 | FCU 1 | Heating/Cooling mode, status | 1 Bit | 1.100 cooling/heating | CWTU |
| 3 | VRF 1 | Control mode, status | 1 Byte | 20.105 HVAC control mode | CWTU |
| 3 | FCU 2 | Heating/Cooling mode | 1 Bit | 1.100 cooling/heating | CWU |
| 3 | FCU 2 | Heating/Cooling mode, status | 1 Bit | 1.100 cooling/heating | CWTU |
| 3 | VRF 2 | Control mode, status | 1 Byte | 20.105 HVAC control mode | CWTU |
| 3 | FCU 3 | Heating/Cooling mode | 1 Bit | 1.100 cooling/heating | CWU |
| 3 | FCU 3 | Heating/Cooling mode, status | 1 Bit | 1.100 cooling/heating | CWTU |
| 3 | VRF 3 | Control mode, status | 1 Byte | 20.105 HVAC control mode | CWTU |
| 4 | FCU 1 | Operation mode, status | 1 Byte | 20.102 HVAC mode | CWTU |
| 4 | FCU 1 | Operation mode | 1 Byte | 20.102 HVAC mode | CWU |
| 4 | VRF 1 | Fan speed, status | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 4 | VRF 1 | Fan speed, status | 1 Byte | 5.100 fan stage (0..255) | CWTU |
| 4 | FCU 2 | Operation mode, status | 1 Byte | 20.102 HVAC mode | CWTU |
| 4 | FCU 2 | Operation mode | 1 Byte | 20.102 HVAC mode | CWU |
| 4 | VRF 2 | Fan speed, status | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 4 | VRF 2 | Fan speed, status | 1 Byte | 5.100 fan stage (0..255) | CWTU |
| 4 | FCU 3 | Operation mode, status | 1 Byte | 20.102 HVAC mode | CWTU |
| 4 | FCU 3 | Operation mode | 1 Byte | 20.102 HVAC mode | CWU |
| 4 | VRF 3 | Fan speed, status | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 4 | VRF 3 | Fan speed, status | 1 Byte | 5.100 fan stage (0..255) | CWTU |
| 5 | FCU 1 | Fan speed, status | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 5 | FCU 1 | Fan speed, status | 1 Byte | 5.100 fan stage (0..255) | CWTU |
| 5 | VRF 1 | Vanes swing of up/down, status | 1 Bit | 1.10 start/stop | CWTU |
| 5 | FCU 2 | Fan speed, status | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 5 | FCU 2 | Fan speed, status | 1 Byte | 5.100 fan stage (0..255) | CWTU |
| 5 | VRF 2 | Vanes swing of up/down, status | 1 Bit | 1.10 start/stop | CWTU |
| 5 | FCU 3 | Fan speed, status | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 5 | FCU 3 | Fan speed, status | 1 Byte | 5.100 fan stage (0..255) | CWTU |
| 5 | VRF 3 | Vanes swing of up/down, status | 1 Bit | 1.10 start/stop | CWTU |
| 6 | FCU 1 | Fan Automatic operation, status | 1 Bit | 1.3 enable | CWTU |
| 6 | VRF 1 | Vanes swing of left/right, status | 1 Bit | 1.10 start/stop | CWTU |
| 6 | FCU 2 | Fan Automatic operation, status | 1 Bit | 1.3 enable | CWTU |
| 6 | VRF 2 | Vanes swing of left/right, status | 1 Bit | 1.10 start/stop | CWTU |
| 6 | FCU 3 | Fan Automatic operation, status | 1 Bit | 1.3 enable | CWTU |
| 6 | VRF 3 | Vanes swing of left/right, status | 1 Bit | 1.10 start/stop | CWTU |
| 7 | FCU 1 | Extended comfort mode | 1 Bit | 1.16 acknowledge | CW |
| 7 | VRF 1 | Timer | 1 Bit | 1.3 enable | CW |
| 7 | FCU 2 | Extended comfort mode | 1 Bit | 1.16 acknowledge | CW |
| 7 | VRF 2 | Timer | 1 Bit | 1.3 enable | CW |
| 7 | FCU 3 | Extended comfort mode | 1 Bit | 1.16 acknowledge | CW |
| 7 | VRF 3 | Timer | 1 Bit | 1.3 enable | CW |
| 8 | FCU 1 | Window contact | 1 Bit | 1.19 window/door | CWTU |
| 8 | VRF 1 | Scene | 1 Byte | 18.1 scene control | CW |
| 8 | FCU 2 | Window contact | 1 Bit | 1.19 window/door | CWTU |
| 8 | VRF 2 | Scene | 1 Byte | 18.1 scene control | CW |
| 8 | FCU 3 | Window contact | 1 Bit | 1.19 window/door | CWTU |
| 8 | VRF 3 | Scene | 1 Byte | 18.1 scene control | CW |
| 9 | FCU 1 | Presence detector | 1 Bit | 1.18 occupancy | CWTU |
| 9 | VRF 1 | Power on/off | 1 Bit | 1.1 switch | CT |
| 9 | FCU 2 | Presence detector | 1 Bit | 1.18 occupancy | CWTU |
| 9 | VRF 2 | Power on/off | 1 Bit | 1.1 switch | CT |
| 9 | FCU 3 | Presence detector | 1 Bit | 1.18 occupancy | CWTU |
| 9 | VRF 3 | Power on/off | 1 Bit | 1.1 switch | CT |
| 10 | FCU 1 | Timer | 1 Bit | 1.3 enable | CW |
| 10 | VRF 1 | Current setpoint adjustment | 2 Bytes | 9.1 temperature (°C) | CT |
| 10 | FCU 2 | Timer | 1 Bit | 1.3 enable | CW |
| 10 | VRF 2 | Current setpoint adjustment | 2 Bytes | 9.1 temperature (°C) | CT |
| 10 | FCU 3 | Timer | 1 Bit | 1.3 enable | CW |
| 10 | VRF 3 | Current setpoint adjustment | 2 Bytes | 9.1 temperature (°C) | CT |
| 11 | FCU 1 | Scene | 1 Byte | 18.1 scene control | CW |
| 11 | VRF 1 | Fan speed | 1 Byte | 5.1 percentage (0..100%) | CT |
| 11 | VRF 1 | Fan speed | 1 Byte | 5.100 fan stage (0..255) | CT |
| 11 | FCU 2 | Scene | 1 Byte | 18.1 scene control | CW |
| 11 | VRF 2 | Fan speed | 1 Byte | 5.1 percentage (0..100%) | CT |
| 11 | VRF 2 | Fan speed | 1 Byte | 5.100 fan stage (0..255) | CT |
| 11 | FCU 3 | Scene | 1 Byte | 18.1 scene control | CW |
| 11 | VRF 3 | Fan speed | 1 Byte | 5.1 percentage (0..100%) | CT |
| 11 | VRF 3 | Fan speed | 1 Byte | 5.100 fan stage (0..255) | CT |
| 12 | FCU 1 | Power on/off, status | 1 Bit | 1.1 switch | CRT |
| 12 | FCU 1 | Power on/off | 1 Bit | 1.1 switch | CT |
| 12 | VRF 1 | Vanes swing of up/down | 1 Bit | 1.10 start/stop | CT |
| 12 | FCU 2 | Power on/off, status | 1 Bit | 1.1 switch | CRT |
| 12 | FCU 2 | Power on/off | 1 Bit | 1.1 switch | CT |
| 12 | VRF 2 | Vanes swing of up/down | 1 Bit | 1.10 start/stop | CT |
| 12 | FCU 3 | Power on/off, status | 1 Bit | 1.1 switch | CRT |
| 12 | FCU 3 | Power on/off | 1 Bit | 1.1 switch | CT |
| 12 | VRF 3 | Vanes swing of up/down | 1 Bit | 1.10 start/stop | CT |
| 13 | FCU 1 | Actual temperature | 2 Bytes | 9.1 temperature (°C) | CRT |
| 13 | VRF 1 | Vanes swing of left/right | 1 Bit | 1.10 start/stop | CT |
| 13 | FCU 2 | Actual temperature | 2 Bytes | 9.1 temperature (°C) | CRT |
| 13 | VRF 2 | Vanes swing of left/right | 1 Bit | 1.10 start/stop | CT |
| 13 | FCU 3 | Actual temperature | 2 Bytes | 9.1 temperature (°C) | CRT |
| 13 | VRF 3 | Vanes swing of left/right | 1 Bit | 1.10 start/stop | CT |
| 14 | FCU 1 | Current base temperature setpoint, status | 2 Bytes | 9.1 temperature (°C) | CRT |
| 14 | VRF 1 | Control mode | 1 Byte | 20.105 HVAC control mode | CT |
| 14 | FCU 2 | Current base temperature setpoint, status | 2 Bytes | 9.1 temperature (°C) | CRT |
| 14 | VRF 2 | Control mode | 1 Byte | 20.105 HVAC control mode | CT |
| 14 | FCU 3 | Current base temperature setpoint, status | 2 Bytes | 9.1 temperature (°C) | CRT |
| 14 | VRF 3 | Control mode | 1 Byte | 20.105 HVAC control mode | CT |
| 15 | FCU 1 | Current temperature setpoint adjustment, status | 2 Bytes | 9.1 temperature (°C) | CRT |
| 15 | FCU 1 | Current temperature setpoint adjustment | 2 Bytes | 9.1 temperature (°C) | CT |
| 15 | FCU 2 | Current temperature setpoint adjustment, status | 2 Bytes | 9.1 temperature (°C) | CRT |
| 15 | FCU 2 | Current temperature setpoint adjustment | 2 Bytes | 9.1 temperature (°C) | CT |
| 15 | FCU 3 | Current temperature setpoint adjustment, status | 2 Bytes | 9.1 temperature (°C) | CRT |
| 15 | FCU 3 | Current temperature setpoint adjustment | 2 Bytes | 9.1 temperature (°C) | CT |
| 16 | FCU 1 | Heating/Cooling mode | 1 Bit | 1.100 cooling/heating | CT |
| 16 | FCU 1 | Heating/Cooling mode, status | 1 Bit | 1.100 cooling/heating | CRT |
| 16 | FCU 2 | Heating/Cooling mode | 1 Bit | 1.100 cooling/heating | CT |
| 16 | FCU 2 | Heating/Cooling mode, status | 1 Bit | 1.100 cooling/heating | CRT |
| 16 | FCU 3 | Heating/Cooling mode | 1 Bit | 1.100 cooling/heating | CT |
| 16 | FCU 3 | Heating/Cooling mode, status | 1 Bit | 1.100 cooling/heating | CRT |
| 17 | FCU 1 | Operation mode | 1 Byte | 20.102 HVAC mode | CT |
| 17 | FCU 1 | Operation mode, status | 1 Byte | 20.102 HVAC mode | CRT |
| 17 | FCU 2 | Operation mode | 1 Byte | 20.102 HVAC mode | CT |
| 17 | FCU 2 | Operation mode, status | 1 Byte | 20.102 HVAC mode | CRT |
| 17 | FCU 3 | Operation mode | 1 Byte | 20.102 HVAC mode | CT |
| 17 | FCU 3 | Operation mode, status | 1 Byte | 20.102 HVAC mode | CRT |
| 18 | FCU 1 | Heating control value | 1 Bit | 1.1 switch | CRT |
| 18 | FCU 1 | Heating control value | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 18 | FCU 1 | Heating/Cooling control value | 1 Bit | 1.1 switch | CRT |
| 18 | FCU 1 | Heating/cooling control value | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 18 | FCU 2 | Heating control value | 1 Bit | 1.1 switch | CRT |
| 18 | FCU 2 | Heating control value | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 18 | FCU 2 | Heating/Cooling control value | 1 Bit | 1.1 switch | CRT |
| 18 | FCU 2 | Heating/cooling control value | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 18 | FCU 3 | Heating control value | 1 Bit | 1.1 switch | CRT |
| 18 | FCU 3 | Heating control value | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 18 | FCU 3 | Heating/Cooling control value | 1 Bit | 1.1 switch | CRT |
| 18 | FCU 3 | Heating/cooling control value | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 19 | FCU 1 | Cooling control value | 1 Bit | 1.1 switch | CRT |
| 19 | FCU 1 | Cooling control value | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 19 | FCU 2 | Cooling control value | 1 Bit | 1.1 switch | CRT |
| 19 | FCU 2 | Cooling control value | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 19 | FCU 3 | Cooling control value | 1 Bit | 1.1 switch | CRT |
| 19 | FCU 3 | Cooling control value | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 20 | FCU 1 | Fan speed | 1 Byte | 5.1 percentage (0..100%) | CT |
| 20 | FCU 1 | Fan speed | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 20 | FCU 1 | Fan speed | 1 Byte | 5.100 fan stage (0..255) | CT |
| 20 | FCU 1 | Fan speed | 1 Byte | 5.100 fan stage (0..255) | CRT |
| 20 | FCU 2 | Fan speed | 1 Byte | 5.1 percentage (0..100%) | CT |
| 20 | FCU 2 | Fan speed | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 20 | FCU 2 | Fan speed | 1 Byte | 5.100 fan stage (0..255) | CT |
| 20 | FCU 2 | Fan speed | 1 Byte | 5.100 fan stage (0..255) | CRT |
| 20 | FCU 3 | Fan speed | 1 Byte | 5.1 percentage (0..100%) | CT |
| 20 | FCU 3 | Fan speed | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 20 | FCU 3 | Fan speed | 1 Byte | 5.100 fan stage (0..255) | CT |
| 20 | FCU 3 | Fan speed | 1 Byte | 5.100 fan stage (0..255) | CRT |
| 21 | FCU 1 | Fan Automatic operation | 1 Bit | 1.3 enable | CT |
| 21 | FCU 1 | Fan Automatic operation | 1 Bit | 1.3 enable | CRT |
| 21 | FCU 2 | Fan Automatic operation | 1 Bit | 1.3 enable | CT |
| 21 | FCU 2 | Fan Automatic operation | 1 Bit | 1.3 enable | CRT |
| 21 | FCU 3 | Fan Automatic operation | 1 Bit | 1.3 enable | CT |
| 21 | FCU 3 | Fan Automatic operation | 1 Bit | 1.3 enable | CRT |
| 115 | Floor heating | Power on/off | 1 Bit | 1.1 switch | CWU |
| 115 | Floor heating | Power on/off, status | 1 Bit | 1.1 switch | CWTU |
| 116 | Floor heating | External temperature sensor | 2 Bytes | 9.1 temperature (°C) | CWTU |
| 117 | Floor heating | Current temperature setpoint | 2 Bytes | 9.1 temperature (°C) | CWU |
| 117 | Floor heating | Current temperature setpoint, status | 2 Bytes | 9.1 temperature (°C) | CWTU |
| 118 | Floor heating | Timer | 1 Bit | 1.3 enable | CW |
| 119 | Floor heating | Scene | 1 Byte | 18.1 scene control | CW |
| 120 | Floor heating | Power on/off, status | 1 Bit | 1.1 switch | CRT |
| 120 | Floor heating | Power on/off | 1 Bit | 1.1 switch | CT |
| 121 | Floor heating | Actual temperature | 2 Bytes | 9.1 temperature (°C) | CRT |
| 122 | Floor heating | Current temperature setpoint adjustment, status | 2 Bytes | 9.1 temperature (°C) | CRT |
| 122 | Floor heating | Current setpoint adjustment | 2 Bytes | 9.1 temperature (°C) | CT |
| 123 | Floor heating | Heating on/off | 1 Bit | 1.1 switch | CRT |
| 123 | Floor heating | Heating control value | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 124 | Ventilation | Power on/off, status | 1 Bit | 1.1 switch | CW |
| 125 | Ventilation | Fan speed, status | 1 Byte | 5.1 percentage (0..100%) | CW |
| 125 | Ventilation | Fan speed, status | 1 Byte | 5.100 fan stage (0..255) | CW |
| 126 | Ventilation | Fan automatic operation, status | 1 Bit | 1.3 enable | CW |
| 127 | Ventilation | Heat recovery on/off, status | 1 Bit | 1.1 switch | CW |
| 128 | Ventilation | En./Dis. Heat recovery | 1 Bit | 1.3 enable | CW |
| 129 | Ventilation | Filter timer counter change | 2 Bytes | 7.7 time (h) | CW |
| 130 | Ventilation | Filter timer reset, status | 1 Bit | 1.15 reset | CW |
| 131 | Ventilation | Timer | 1 Bit | 1.3 enable | CW |
| 132 | Ventilation | Scene | 1 Byte | 18.1 scene control | CW |
| 133 | Ventilation | CO2 value | 2 Bytes | 9.8 parts/million (ppm) | CWTU |
| 134 | Ventilation | PM2.5 value | 2 Bytes | 9.30 concentration (µg/m³) | CWTU |
| 135 | Ventilation | VOC value | 2 Bytes | 9.30 concentration (µg/m³) | CWTU |
| 136 | Ventilation | Power on/off | 1 Bit | 1.1 switch | CT |
| 137 | Ventilation | Fan speed | 1 Byte | 5.1 percentage (0..100%) | CT |
| 137 | Ventilation | Fan speed | 1 Byte | 5.100 fan stage (0..255) | CT |
| 138 | Ventilation | Fan automatic operation | 1 Bit | 1.3 enable | CT |
| 139 | Ventilation | Heat recovery on/off | 1 Bit | 1.1 switch | CT |
| 140 | Ventilation | Filter timer counter | 2 Bytes | 7.7 time (h) | CT |
| 141 | Ventilation | Filter alarm | 1 Bit | 1.5 alarm | CT |
| 142 | Ventilation | Filter timer reset | 1 Bit | 1.15 reset | CT |
| 143 | Output | Fan speed on/off, status | 1 Bit | 1.1 switch | CRT |
| 144 | Output | Fan speed, status | 1 Byte | 5.100 fan stage (0..255) | CRT |
| 144 | Output | Fan speed, status | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 145 | Output | Fan speed 1, status | 1 Bit | 1.1 switch | CRT |
| 146 | Output | Fan speed 2, status | 1 Bit | 1.1 switch | CRT |
| 147 | Output | Fan speed 3, status | 1 Bit | 1.1 switch | CRT |
| 148 | Output | Fan speed | 1 Byte | 5.100 fan stage (0..255) | CW |
| 148 | Output | Fan speed | 1 Byte | 5.1 percentage (0..100%) | CW |
| 149 | Output | Fan speed 1 | 1 Bit | 1.1 switch | CW |
| 150 | Output | Fan speed 2 | 1 Bit | 1.1 switch | CW |
| 151 | Output | Fan speed 3 | 1 Bit | 1.1 switch | CW |
| 152 | Output | Valve status, Heating | 1 Bit | 1.1 switch | CRT |
| 152 | Output | Valve status, Floor Heating | 1 Bit | 1.1 switch | CRT |
| 152 | Output | Valve status | 1 Bit | 1.1 switch | CRT |
| 153 | Output | Valve status, Cooling | 1 Bit | 1.1 switch | CRT |
| 153 | Output | Valve status, 2pipe | 1 Bit | 1.1 switch | CRT |
| 154 | Output | Control value, Heating | 1 Bit | 1.1 switch | CW |
| 154 | Output | Control value, Floor Heating | 1 Bit | 1.1 switch | CW |
| 154 | Output | Control value | 1 Bit | 1.1 switch | CW |
| 155 | Output | Control value, Cooling | 1 Bit | 1.1 switch | CW |
| 155 | Output | Control value, 2pipe | 1 Bit | 1.1 switch | CW |
| 156 | General | In operation | 1 Bit | 1.1 switch | CRT |
| 157 | General | Dis/En Proximity function | 1 Bit | 1.3 enable | CW |
| 158 | General | Proximity input | 1 Bit | 1.1 switch | CW |
| 159 | General | Proximity output, 1bit value | 1 Bit | 1.1 switch | CT |
| 159 | General | Proximity output, scene NO. | 1 Byte | 17.1 scene number | CT |
| 159 | General | Proximity output, 1byte value | 1 Byte | 5.10 counter pulses (0..255) | CT |
| 159 | General | Proximity output, 1byte value | 1 Byte | 5.1 percentage (0..100%) | CT |
| 160 | General | Ambience light | 1 Byte | 5.1 percentage (0..100%) | CWT |
Parameters (241)
| Parameter | Type | Default |
|---|---|---|
| Send delay after voltage recovery [0..15] | unsignedInt 0…15 | 5 |
| Send cycle of "In operation" telegram [1..240,0=inactive] | unsignedInt 0…240 | 0 |
| The Proximity function triggered via | list | Sensor |
| Sensor sensitivity | list | Medium |
| Object type of output value | list | 1bit[On/Off] |
| Reaction for proximity approaching | list | Send a value |
| Output value [On/Off] | list | ON |
| Output scene NO.[1..64] | list | Scene No.1 |
| Output value [0..255] | unsignedInt 0…255 | 255 |
| Output value [0..100] | unsignedInt 0…100 | 100 |
| Delay time for sending [0..65535] | unsignedInt 0…65535 | 0 |
| Reaction for proximity leaving | list | No action |
| Output value [On/Off] | list | OFF |
| Output scene NO.[1..64] | list | Scene No.2 |
| Output value [0..255] | unsignedInt 0…255 | 0 |
| Output value [0..100] | unsignedInt 0…100 | 0 |
| Delay time for sending [5..65535] | unsignedInt 5…65535 | 10 |
| Flashing duration in operation | unsignedInt 0…5 | 1 |
| Flashing frequency in operation | unsignedInt 0…50 | 10 |
| Screen brightness setting | list | Control by proximity sensor |
| Brightness value in normal mode | unsignedInt 0…100 | 100 |
| Ambience light | list | Control by proximity sensor |
| Ambience light | list | Disable |
| Brightness for ambience light | unsignedInt 0…100 | 100 |
| General time for screen turn off &ambience light turn on/off (from 0 to 100%/from 100% to 0) | unsignedInt 1…10 | 5 |
| Delay for screen turn off&ambience light turn on after proximity leaving | unsignedInt 0…255 | 60 |
| Brightness value | unsignedInt 0…100 | 100 |
| Delay time for normal to standby [0..255, 0=inactive] | unsignedInt 0…255 | 10 |
| Brightness value in standby mode [0..50] | unsignedInt 0…50 | 10 |
| Delay time for exiting setting status [3..15] | unsignedInt 3…15 | 5 |
| Temperature display unit | list | Celsius(°C) |
| Temperature calibration | list | 0.0 |
| Send temperature when the result change by | list | 1.0K |
| Cyclically send temperature [0..255,0=inactive] | unsignedInt 0…255 | 10 |
| Send alarm telegram for low/high temperature | list | No respond |
| Threshold value for low temperature alarm | list | 0 |
| Threshold value for high temperature alarm | list | 45 |
| Room temperature control function 1 as | list | Disable |
| Floor heating function | unsignedInt 0…1 | 0 |
| Ventilation function | unsignedInt 0…1 | 0 |
| Setpoint Temperature error | unsignedInt 0…1 | 0 |
| Work mode | list | Master |
| Room temperature reference from | list | Internal sensor |
| Period for request external sensor [0..255] | unsignedInt 0…255 | 5 |
| Combination ratio | list | 50% Internal to 50% External |
| Cyclically send temperature [0...255,0=inactive] | unsignedInt 0…255 | 0 |
| Control value after temp. error [0..100] (If 2-point control, set value '0'=0, set value '>0'=1) | unsignedInt 0…100 | 0 |
| Interface display temperature | list | Actual temperature |
| The interval for displayed temperature alternately | list | 10 |
| Setpoint temperature adjustment step | list | 0.5K |
| Default setpoint temperature [5..40] | list | 20 |
| Min. setpoint temperature [5..40] | list | 16 |
| Max. setpoint temperature [5..40] | list | 32 |
| Power on/off status after download | list | ON |
| Power on/off status after voltage recovery | list | As before voltage failure |
| Temperature control method | list | Heating on/off (2 point control) |
| Object value of Heating on/off | list | Heat on=1, Heat off=0 |
| Lower Hysteresis [0..200] | unsignedInt 0…200 | 10 |
| Upper Hysteresis [0..200] | unsignedInt 0…200 | 10 |
| Invert control value | unsignedInt 0…1 | 0 |
| PWM cycle time [1..255] | unsignedInt 1…255 | 15 |
| Heating speed | list | Underfloor heating(5K/240min) |
| Proportional range [10..100] | unsignedInt 10…100 | 40 |
| Reset time [0..255] | unsignedInt 0…255 | 150 |
| Send control value on change by [0..100,0=inactive] | unsignedInt 0…100 | 4 |
| Cyclically send heating control value [0..255] | unsignedInt 0…255 | 0 |
| Timer | unsignedInt 0…1 | 0 |
| Scene | unsignedInt 0…1 | 0 |
| 1->Assign scene NO.[1..64,0=inactive] | unsignedInt 0…64 | 0 |
| ON/OFF | list | Unchange |
| Temperature | list | Unchange |
| 2->Assign scene NO.[1..64,0=inactive] | unsignedInt 0…64 | 0 |
| 3->Assign scene NO.[1..64,0=inactive] | unsignedInt 0…64 | 0 |
| 4->Assign scene NO.[1..64,0=inactive] | unsignedInt 0…64 | 0 |
| 5->Assign scene NO.[1..64,0=inactive] | unsignedInt 0…64 | 0 |
| Fan speed level | list | 3 |
| Power on/off status after download | list | OFF |
| Default fan speed after ventilation on | list | Fan speed 1 |
| Object datatype of 1byte fan speed | list | Percentage (DPT_5.001) |
| Output value for Fan speed 1 | unsignedInt 1…100 | 33 |
| Output value for Fan speed 2 | unsignedInt 1…100 | 67 |
| Output value for Fan speed 3 | unsignedInt 1…100 | 100 |
| Status value for Fan speed 1 | unsignedInt 1…100 | 33 |
| Status value for Fan speed 2 | unsignedInt 1…100 | 67 |
| Status value for Fan speed 3 | unsignedInt 1…100 | 100 |
| Output value for Fan speed 1 | unsignedInt 1…255 | 1 |
| Output value for Fan speed 2 | unsignedInt 1…255 | 2 |
| Output value for Fan speed 3 | unsignedInt 1…255 | 3 |
| Status value for Fan speed 1 | unsignedInt 1…255 | 1 |
| Status value for Fan speed 2 | unsignedInt 1…255 | 2 |
| Status value for Fan speed 3 | unsignedInt 1…255 | 3 |
| Automatic operation function | unsignedInt 0…1 | 0 |
| Control value reference from | list | CO2 |
| Object datatype of CO2 | list | Float value in ppm(DPT_9.008) |
| Object datatype of PM2.5 | list | Float value in ug/m3(DPT_9.030) |
| Object datatype of VOC | list | Float value in ug/m3(DPT_9.030) |
| Period for request control value [0..255] | unsignedInt 0…255 | 10 |
| The speed status after control value error | list | OFF |
| Threshold value speed OFF<->1 [1..4000] | unsignedInt 1…4000 | 400 |
| Threshold value speed 1<->2 [1..4000] | unsignedInt 1…4000 | 800 |
| Threshold value speed 2<->3 [1..4000] | unsignedInt 1…4000 | 1200 |
| Hysteresis value is threshold value in +/-[100..400] | unsignedInt 100…400 | 200 |
| Threshold value speed OFF<->1 [1..999] | unsignedInt 1…999 | 35 |
| Threshold value speed 1<->2 [1..999] | unsignedInt 1…999 | 75 |
| Threshold value speed 2<->3 [1..999] | unsignedInt 1…999 | 115 |
| Hysteresis value is threshold value in +/-[10..30] | unsignedInt 10…30 | 10 |
| Minimum time in fan speed [0..65535] | unsignedInt 0…65535 | 10 |
| Heat Recovery function | unsignedInt 0…1 | 0 |
| Filter timer counter | unsignedInt 0…1 | 0 |
| Evaluation time [100..10000] | unsignedInt 100…10000 | 1000 |
| Fan level | list | Unchange |
| Heat Recovery | list | Unchange |
| Room temperature control function 2 as | list | Disable |
| Room temperature control function 3 as | list | Disable |
| Outputs 1~3 config as | list | Disable |
| When bus recovery, fan speed is | list | Fan speed 1 |
| Fan operation mode | list | Changeover switch |
| Delay between fan speed switch | list | 400ms |
| Output value for fan speed 1 | unsignedInt 1…255 | 1 |
| Output value for fan speed 2 | unsignedInt 1…255 | 2 |
| Output value for fan speed 3 | unsignedInt 1…255 | 3 |
| Status value for fan speed 1 | unsignedInt 1…255 | 1 |
| Status value for fan speed 2 | unsignedInt 1…255 | 2 |
| Status value for fan speed 3 | unsignedInt 1…255 | 3 |
| Outputs 4~5 config as | list | Disable |
| When power recovery, valve status for Heating control is | list | Valve open |
| When power recovery, valve status for Cooling control is | list | Valve open |
| When power recovery, valve status for Floor Heating is | list | Valve open |
| When power recovery, valve status for Valve control(2pipe) is | list | Valve open |
| When power recovery, valve status is | list | Valve open |
| Delay between valve switch | list | 400ms |
| Output value for fan speed 1 | unsignedInt 1…100 | 33 |
| Output value for fan speed 2 | unsignedInt 1…100 | 67 |
| Output value for fan speed 3 | unsignedInt 1…100 | 100 |
| Status value for fan speed 1 | unsignedInt 1…100 | 33 |
| Status value for fan speed 2 | unsignedInt 1…100 | 67 |
| Status value for fan speed 3 | unsignedInt 1…100 | 100 |
| Function of button 1 | list | Fan speed |
| Function of button 2 | list | Function page |
| Function of button 3 | list | Power on/off |
| Function of button 4 | list | Control mode |
| Long operation for button after [3..25] | unsignedInt 3…25 | 10 |
| Min. setpoint temperature [5..37] | list | 5 |
| Max. setpoint temperature [5..37] | list | 37 |
| Room temperature control mode | list | Heating |
| Room temperature operation mode | unsignedInt 0…1 | 1 |
| Initial setpoint temperature | list | 20.0 |
| Setpoint Temperature error min/initial | unsignedInt 0…1 | 0 |
| Setpoint Temperature error max/initial | unsignedInt 0…1 | 0 |
| Controller status after download | list | Standby mode |
| Controller status after voltage recovery | list | As before voltage failure |
| Extended comfort mode [0..255,0=inactive] | unsignedInt 0…255 | 0 |
| Setpoint method for operating mode | list | Absolute |
| Base setpoint temperature | list | 20.0 |
| Setpoint Temperature error min/relative base | unsignedInt 0…1 | 0 |
| Setpoint Temperature error max/relative base | unsignedInt 0…1 | 0 |
| Reduced heating in standby mode [0..10] | list | 2 |
| Reduced heating in economy mode [0..10] | list | 4 |
| Setpoint temperature in frost protection [5..10] | list | 7 |
| Setpoint temperature in comfort mode [5..37] | list | 21 |
| Setpoint temperature in standby mode [5..37] | list | 19 |
| Setpoint temperature in economy mode [5..37] | list | 17 |
| Setpoint Temperature error min/heat absolute | unsignedInt 0…1 | 0 |
| Setpoint Temperature error max/heat absolute | unsignedInt 0…1 | 0 |
| Type of heating control | list | Switching on/off(use 2-point control) |
| Heating speed | list | Hot water heating(5K/150min) |
| Cyclically send control value[0..255] | unsignedInt 0…255 | 0 |
| Increased cooling in standby mode [0..10] | list | 2 |
| Increased cooling in economy mode[0..10] | list | 4 |
| Setpoint temperature in heat protection[30..37] | list | 35 |
| Setpoint temperature in comfort mode [5..37] | list | 23 |
| Setpoint temperature in standby mode [5..37] | list | 25 |
| Setpoint temperature in economy mode[5..37] | list | 27 |
| Setpoint temperature in heat protection [30..37] | list | 35 |
| Setpoint Temperature error min/cool absolute | unsignedInt 0…1 | 0 |
| Setpoint Temperature error max/cool absolute | unsignedInt 0…1 | 0 |
| Type of cooling control | list | Switching on/off(use 2-point control) |
| Cooling speed | list | Cooling ceiling(5K/240min) |
| Heating/Cooling switchover | list | Only via object |
| Heating/Cooling status after download | list | Cooling |
| Heating/Cooling status after voltage recovery | list | As before voltage failure |
| Room temperature control system | list | 4 pipes system |
| Upper dead zone | list | 2.0 |
| Lower dead zone | list | 2.0 |
| Minimum zone between heating and cooling setpoint | list | 2.0 |
| Setpoint Temperature error min/HC absolute | unsignedInt 0…1 | 0 |
| Setpoint Temperature error max/HC absolute | unsignedInt 0…1 | 0 |
| Type of heating/cooling control | list | Switching on/off(use 2-point control) |
| Window contact input function | unsignedInt 0…1 | 0 |
| Delay for window contact [0..65535] | unsignedInt 0…65535 | 15 |
| Operation mode for open window | list | Economy mode |
| Bus presence detector function | unsignedInt 0…1 | 0 |
| Fan | unsignedInt 0…1 | 0 |
| Automatic operation function | list | Disable |
| Threshold value speed OFF<->1 [1..255] | unsignedInt 1…255 | 80 |
| Threshold value speed 1<->2 [1..255] | unsignedInt 1…255 | 150 |
| Threshold value speed 2<->3 [1..255] | unsignedInt 1…255 | 200 |
| Hysteresis threshold value in +/-[0..50] | unsignedInt 0…50 | 10 |
| Temperature difference speed OFF<->1 [1..200] | unsignedInt 1…200 | 20 |
| Temperature difference speed 1<->2 [1..200] | unsignedInt 1…200 | 30 |
| Temperature difference speed 2<->3 [1..200] | unsignedInt 1…200 | 40 |
| Hysteresis temperature difference in [0..50] | unsignedInt 0…50 | 10 |
| Minimum time in fan speed [0..65535] | unsignedInt 0…65535 | 60 |
| Operation mode | list | Unchange |
| Period for request external sensor [0...255] | unsignedInt 0…255 | 10 |
| Object datatype of setpoint | list | Float value in °C(DPT_9.001) |
| Setpoint temperature adjustment step | list | 1K |
| Min. setpoint temperature [16..32] | list | 16 |
| Max. setpoint temperature [16..32] | list | 32 |
| Vanes swing | unsignedInt 0…1 | 0 |
| Send delay between telegrams | list | 100ms |
| Heating mode | unsignedInt 0…1 | 1 |
| Output value for Heating | unsignedInt 0…255 | 1 |
| Status value for Heating | unsignedInt 0…255 | 1 |
| Cooling mode | unsignedInt 0…1 | 1 |
| Output value for Cooling | unsignedInt 0…255 | 3 |
| Status value for Cooling | unsignedInt 0…255 | 3 |
| Fan mode | unsignedInt 0…1 | 1 |
| Output value for Fan | unsignedInt 0…255 | 9 |
| Status value for Fan | unsignedInt 0…255 | 9 |
| Dehumidification mode | unsignedInt 0…1 | 1 |
| Output value for Dehumidification | unsignedInt 0…255 | 14 |
| Status value for Dehumidification | unsignedInt 0…255 | 14 |
| Output value for Fan speed auto | unsignedInt 0…100 | 0 |
| Output value for Fan speed 1 | unsignedInt 0…100 | 33 |
| Output value for Fan speed 2 | unsignedInt 0…100 | 67 |
| Output value for Fan speed 3 | unsignedInt 0…100 | 100 |
| Status value for Fan speed auto | unsignedInt 0…100 | 0 |
| Status value for Fan speed 1 | unsignedInt 0…100 | 33 |
| Status value for Fan speed 2 | unsignedInt 0…100 | 67 |
| Status value for Fan speed 3 | unsignedInt 0…100 | 100 |
| Output value for Fan speed auto | unsignedInt 0…255 | 0 |
| Output value for Fan speed 1 | unsignedInt 0…255 | 1 |
| Output value for Fan speed 2 | unsignedInt 0…255 | 2 |
| Output value for Fan speed 3 | unsignedInt 0…255 | 3 |
| Status value for Fan speed auto | unsignedInt 0…255 | 0 |
| Status value for Fan speed 1 | unsignedInt 0…255 | 1 |
| Status value for Fan speed 2 | unsignedInt 0…255 | 2 |
| Status value for Fan speed 3 | unsignedInt 0…255 | 3 |
| Mode | list | Unchange |
| Fan | list | Unchange |
Version history
| Application | App no | Fingerprint | First seen | Size | File |
|---|---|---|---|---|---|
| Rotary thermostate panel 1.0 latest | $F068 | BBF2 | 2026-11-25 | 156 KB | Download |
About this file
This is the official ETS product database for the Zhejiang Moorgen Group Co.,Ltd MK8380 (MK8380), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.
More from Zhejiang Moorgen Group Co.,Ltd
- KNX Smart panel with 4-Fold Switch output,1/2/3/4/6 button MK8036/37/38/39/52/53/32/50
- KNX Smart Thermostat panel MK8055/56
- 1/2/3-gang smart panel MK8391/77/78
- 3-Channel Embedded Actuator MK2009
- 0-10V Fan Coil Actuator MK3001
- MK7018 MK7018
- KNX/DALI Gateway MK7023
- KNX Gateway for RS485/RS232 MK7220
- 4-Inch Smart Touch Panel MK8201