KNX Database
Zennio ZSIRBOX RingBOX

RingBOX ZSIRBOX

Zennio · Order number ZSIRBOX · Access Control › Doorbell

RingBOX. KNX Doorbell - 4 doorbells and 8 tones

Download .knxprod RingBOX 1.0 1.0 · 134 KB

Product

ManufacturerZennio
Product nameRingBOX
Order numberZSIRBOX
HardwareRingBOX
MediumTwisted Pair
Bus current (mA)10
Rail mountedNo
RegistrationCertified · 2026-04-09
Languagesen-US, es-ES, de-DE, fr-FR, it-IT, ru-RU, uk-UA
Catalog entryM-0071_H-ZSIRBOX-0_HP-2421-10-B27C_CI-ZSIRBOX-1
FingerprintB27C
SHA-25673c979f0808075bd18ea5dbf707650f9dc0e86e8b5932d9712e66cb14e7d93f2
First seen2026-11-25
Markets59 markets

Application program: RingBOX 1.0 1.0

Application number$2421
Version1.0
Mask versionMV-07B0 (System B)
KNX Data SecureYes
Minimum ETS version5.0
Parameters40
Group objects31
Group objects (31)
NoNameFunctionSizeDPTFlags
0[Doorbell 1][{{0}}] Control0 = Play Doorbell1 Bit1.16 acknowledgeCWT
0[Doorbell 1][{{0}}] Control1 = Play Doorbell1 Bit1.16 acknowledgeCWT
0[Doorbell 2][{{0}}] Control0 = Play Doorbell1 Bit1.16 acknowledgeCWT
0[Doorbell 2][{{0}}] Control1 = Play Doorbell1 Bit1.16 acknowledgeCWT
0[Doorbell 3][{{0}}] Control0 = Play Doorbell1 Bit1.16 acknowledgeCWT
0[Doorbell 3][{{0}}] Control1 = Play Doorbell1 Bit1.16 acknowledgeCWT
0[Doorbell 4][{{0}}] Control0 = Play Doorbell1 Bit1.16 acknowledgeCWT
0[Doorbell 4][{{0}}] Control1 = Play Doorbell1 Bit1.16 acknowledgeCWT
1[Doorbell] Control0 = Play Doorbell 1; 1 = Play Doorbell 2; … ; 3 = Play Doorbell 41 Byte5.10 counter pulses (0..255)CWT
1[Doorbell 1][{{0}}] Tone0 = Tone 1; 1 = Tone 2; … ; 7 = Tone 81 Byte5.10 counter pulses (0..255)CWT
1[Doorbell 2][{{0}}] Tone0 = Tone 1; 1 = Tone 2; … ; 7 = Tone 81 Byte5.10 counter pulses (0..255)CWT
1[Doorbell 3][{{0}}] Tone0 = Tone 1; 1 = Tone 2; … ; 7 = Tone 81 Byte5.10 counter pulses (0..255)CWT
1[Doorbell 4][{{0}}] Tone0 = Tone 1; 1 = Tone 2; … ; 7 = Tone 81 Byte5.10 counter pulses (0..255)CWT
2[Doorbell] Scenes0 – 63 (Execute 1 – 64)1 Byte18.1 scene controlCW
2[Doorbell 1][{{0}}] Volume0% … 100%1 Byte5.1 percentage (0..100%)CWT
2[Doorbell 2][{{0}}] Volume0% … 100%1 Byte5.1 percentage (0..100%)CWT
2[Doorbell 3][{{0}}] Volume0% … 100%1 Byte5.1 percentage (0..100%)CWT
2[Doorbell 4][{{0}}] Volume0% … 100%1 Byte5.1 percentage (0..100%)CWT
3[Doorbell 1][{{0}}] Do Not Disturb Mode0 = Normal; 1 = Do Not Disturb1 Bit1.3 enableCRWT
3[Doorbell 1][{{0}}] Do Not Disturb Mode0 = Do Not Disturb; 1 = Normal1 Bit1.3 enableCRWT
3[Doorbell 2][{{0}}] Do Not Disturb Mode0 = Normal; 1 = Do Not Disturb1 Bit1.3 enableCRWT
3[Doorbell 2][{{0}}] Do Not Disturb Mode0 = Do Not Disturb; 1 = Normal1 Bit1.3 enableCRWT
3[Doorbell 3][{{0}}] Do Not Disturb Mode0 = Normal; 1 = Do Not Disturb1 Bit1.3 enableCRWT
3[Doorbell 3][{{0}}] Do Not Disturb Mode0 = Do Not Disturb; 1 = Normal1 Bit1.3 enableCRWT
3[Doorbell 4][{{0}}] Do Not Disturb Mode0 = Normal; 1 = Do Not Disturb1 Bit1.3 enableCRWT
3[Doorbell 4][{{0}}] Do Not Disturb Mode0 = Do Not Disturb; 1 = Normal1 Bit1.3 enableCRWT
19[Heartbeat] Object to Send '1'Sending of '1' Periodically1 Bit1.17 triggerCRT
20[Heartbeat] Device RecoverySend 01 Bit1.17 triggerCRT
21[Heartbeat] Device RecoverySend 11 Bit1.17 triggerCRT
22[Test] InputSee command table14 Bytes16.1 Character String (ISO 8859-1)CW
23[Test] OutputSee command table14 Bytes16.1 Character String (ISO 8859-1)CRT
Parameters (23)
ParameterTypeDefault
checkHWlist
Debug ObjectsunsignedInt 0…2550
Heartbeat (Periodic Alive Notification)unsignedInt 0…2550
PeriodunsignedInt 1…655351
Device Recovery Objects (Send 0 and 1)unsignedInt 0…2550
DelayunsignedInt 0…2550
Priority DoorbelllistDoorbell 1
DoorbellsunsignedInt 0…2551
ScenesunsignedInt 0…2550
Number of DoorbellsunsignedInt 1…41
Scenes NumberunsignedInt 0…50
Nametext
Valuelist1 = Play Doorbell
Default Tone (after Programming)listTone 1
Number of RepetitionsunsignedInt 1…101
Default Volume (after Programming)listHigh
Do Not Disturb Mode Polaritylist0 = Normal; 1 = Do Not Disturb
Scene Number [1 to 64] (0 = Disabled)unsignedInt 0…640
TonelistCurrent Tone
VolumelistCurrent Volume
ModelistCurrent Mode
Play DoorbelllistNone
Change Doorbells ValuesunsignedInt 0…2550

Version history

ApplicationApp noFingerprintFirst seenSizeFile
RingBOX 1.0 1.0 latest$2421B27C2026-11-25134 KBDownload

About this file

This is the official ETS product database for the Zennio RingBOX (ZSIRBOX), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.

More from Zennio

All Zennio products