KNX SA 16MDC SMI LoVo REG 2022489
WAREMA Renkhoff SE · Order number 2022489 · Actuator › Venetian blind
KNX SA 16MDC SMI LoVo REG
Download .knxprod KNX SA 16MDC SMI LoVo REG 1.0 · 349 KB
Product
| Manufacturer | WAREMA Renkhoff SE |
|---|---|
| Product name | KNX SA 16MDC SMI LoVo REG |
| Order number | 2022489 |
| Hardware | KNX SA 16MDC SMI LoVo REG |
| Medium | Twisted Pair |
| Bus current (mA) | 5 |
| Rail mounted | Yes |
| Width (mm) | 54 |
| Registration | Certified · 2019-03-25 |
| Languages | de-DE |
| Catalog entry | M-006B_H-0013-0_HP-FFE6-10-E0C4_CI-2022489-1 |
| Fingerprint | E0C4 |
| SHA-256 | 397af689e038c2f7bfbea8341336552f696d1d3cd899ee48ac0aed53cb13d60a |
| First seen | 2026-11-25 |
| Markets | 42 markets |
Application program: KNX SA 16MDC SMI LoVo REG 1.0
| Application number | $FFE6 |
|---|---|
| Version | 1.0 |
| Mask version | MV-07B0 (System B) |
| KNX Data Secure | No |
| Minimum ETS version | 5.0 |
| Parameters | 4055 |
| Group objects | 519 |
Group objects (519)
| No | Name | Function | Size | DPT | Flags |
|---|---|---|---|---|---|
| 1 | Output 1 | Up/Down move command | 1 Bit | DPT.1 | CW |
| 2 | Output 1 | Stop/Step move command | 1 Bit | DPT.1 | CW |
| 2 | Output 1 | Stop command | 1 Bit | DPT.1 | CW |
| 3 | Output 1 | Move to blind length manually | 1 Byte | DPT.5 | CW |
| 4 | Output 1 | Move to slat position manually | 1 Byte | DPT.5 | CW |
| 5 | Output 1 | Enable automatic objects | 1 Bit | DPT.1 | CW |
| 6 | Output 1 | Move to blind length automatically | 1 Byte | DPT.5 | CW |
| 7 | Output 1 | Move to slat position automatically | 1 Byte | DPT.5 | CW |
| 8 | Output 1 | Move to automatic position 1 | 1 Bit | DPT.1 | CW |
| 9 | Output 1 | Move to automatic position 2 | 1 Bit | DPT.1 | CW |
| 10 | Output 1 | Save automatic position 1 | 1 Bit | DPT.1 | CW |
| 11 | Output 1 | Save automatic position 2 | 1 Bit | DPT.1 | CW |
| 12 | Output 1 | Automatic position toggle | 1 Bit | DPT.1 | CW |
| 13 | Output 1 | Limitation of manual operation in automatic mode | 1 Bit | DPT.1 | CW |
| 14 | Output 1 | Dwell time active | 1 Bit | DPT.1 | CRT |
| 15 | Output 1 | Safety object C1 | 1 Bit | DPT.1 | CW |
| 16 | Output 1 | Disable object | 1 Bit | DPT.1 | CW |
| 17 | Output 1 | Scenes | 1 Byte | DPT.18 | CW |
| 18 | Output 1 | Disable scenes | 1 Bit | DPT.1 | CW |
| 19 | Output 1 | Upper limit position reached | 1 Bit | DPT.1 | CRT |
| 20 | Output 1 | Actual blind length | 1 Byte | DPT.5 | CRT |
| 21 | Output 1 | Actual slat position | 1 Byte | DPT.5 | CRT |
| 22 | Output 1 | Error | 1 Bit | DPT.1 | CRT |
| 23 | Output 2 | Up/Down move command | 1 Bit | DPT.1 | CW |
| 24 | Output 2 | Stop/Step move command | 1 Bit | DPT.1 | CW |
| 24 | Output 2 | Stop command | 1 Bit | DPT.1 | CW |
| 25 | Output 2 | Move to blind length manually | 1 Byte | DPT.5 | CW |
| 26 | Output 2 | Move to slat position manually | 1 Byte | DPT.5 | CW |
| 27 | Output 2 | Enable automatic objects | 1 Bit | DPT.1 | CW |
| 28 | Output 2 | Move to blind length automatically | 1 Byte | DPT.5 | CW |
| 29 | Output 2 | Move to slat position automatically | 1 Byte | DPT.5 | CW |
| 30 | Output 2 | Move to automatic position 1 | 1 Bit | DPT.1 | CW |
| 31 | Output 2 | Move to automatic position 2 | 1 Bit | DPT.1 | CW |
| 32 | Output 2 | Save automatic position 1 | 1 Bit | DPT.1 | CW |
| 33 | Output 2 | Save automatic position 2 | 1 Bit | DPT.1 | CW |
| 34 | Output 2 | Automatic position toggle | 1 Bit | DPT.1 | CW |
| 35 | Output 2 | Limitation of manual operation in automatic mode | 1 Bit | DPT.1 | CW |
| 36 | Output 2 | Dwell time active | 1 Bit | DPT.1 | CRT |
| 37 | Output 2 | Safety object C2 | 1 Bit | DPT.1 | CW |
| 38 | Output 2 | Disable object | 1 Bit | DPT.1 | CW |
| 39 | Output 2 | Scenes | 1 Byte | DPT.18 | CW |
| 40 | Output 2 | Disable scenes | 1 Bit | DPT.1 | CW |
| 41 | Output 2 | Upper limit position reached | 1 Bit | DPT.1 | CRT |
| 42 | Output 2 | Actual blind length | 1 Byte | DPT.5 | CRT |
| 43 | Output 2 | Actual slat position | 1 Byte | DPT.5 | CRT |
| 44 | Output 2 | Error | 1 Bit | DPT.1 | CRT |
| 45 | Output 3 | Up/Down move command | 1 Bit | DPT.1 | CW |
| 46 | Output 3 | Stop/Step move command | 1 Bit | DPT.1 | CW |
| 46 | Output 3 | Stop command | 1 Bit | DPT.1 | CW |
| 47 | Output 3 | Move to blind length manually | 1 Byte | DPT.5 | CW |
| 48 | Output 3 | Move to slat position manually | 1 Byte | DPT.5 | CW |
| 49 | Output 3 | Enable automatic objects | 1 Bit | DPT.1 | CW |
| 50 | Output 3 | Move to blind length automatically | 1 Byte | DPT.5 | CW |
| 51 | Output 3 | Move to slat position automatically | 1 Byte | DPT.5 | CW |
| 52 | Output 3 | Move to automatic position 1 | 1 Bit | DPT.1 | CW |
| 53 | Output 3 | Move to automatic position 2 | 1 Bit | DPT.1 | CW |
| 54 | Output 3 | Save automatic position 1 | 1 Bit | DPT.1 | CW |
| 55 | Output 3 | Save automatic position 2 | 1 Bit | DPT.1 | CW |
| 56 | Output 3 | Automatic position toggle | 1 Bit | DPT.1 | CW |
| 57 | Output 3 | Limitation of manual operation in automatic mode | 1 Bit | DPT.1 | CW |
| 58 | Output 3 | Dwell time active | 1 Bit | DPT.1 | CRT |
| 59 | Output 3 | Safety object C3 | 1 Bit | DPT.1 | CW |
| 60 | Output 3 | Disable object | 1 Bit | DPT.1 | CW |
| 61 | Output 3 | Scenes | 1 Byte | DPT.18 | CW |
| 62 | Output 3 | Disable scenes | 1 Bit | DPT.1 | CW |
| 63 | Output 3 | Upper limit position reached | 1 Bit | DPT.1 | CRT |
| 64 | Output 3 | Actual blind length | 1 Byte | DPT.5 | CRT |
| 65 | Output 3 | Actual slat position | 1 Byte | DPT.5 | CRT |
| 66 | Output 3 | Error | 1 Bit | DPT.1 | CRT |
| 67 | Output 4 | Up/Down move command | 1 Bit | DPT.1 | CW |
| 68 | Output 4 | Stop/Step move command | 1 Bit | DPT.1 | CW |
| 68 | Output 4 | Stop command | 1 Bit | DPT.1 | CW |
| 69 | Output 4 | Move to blind length manually | 1 Byte | DPT.5 | CW |
| 70 | Output 4 | Move to slat position manually | 1 Byte | DPT.5 | CW |
| 71 | Output 4 | Enable automatic objects | 1 Bit | DPT.1 | CW |
| 72 | Output 4 | Move to blind length automatically | 1 Byte | DPT.5 | CW |
| 73 | Output 4 | Move to slat position automatically | 1 Byte | DPT.5 | CW |
| 74 | Output 4 | Move to automatic position 1 | 1 Bit | DPT.1 | CW |
| 75 | Output 4 | Move to automatic position 2 | 1 Bit | DPT.1 | CW |
| 76 | Output 4 | Save automatic position 1 | 1 Bit | DPT.1 | CW |
| 77 | Output 4 | Save automatic position 2 | 1 Bit | DPT.1 | CW |
| 78 | Output 4 | Automatic position toggle | 1 Bit | DPT.1 | CW |
| 79 | Output 4 | Limitation of manual operation in automatic mode | 1 Bit | DPT.1 | CW |
| 80 | Output 4 | Dwell time active | 1 Bit | DPT.1 | CRT |
| 81 | Output 4 | Safety object C4 | 1 Bit | DPT.1 | CW |
| 82 | Output 4 | Disable object | 1 Bit | DPT.1 | CW |
| 83 | Output 4 | Scenes | 1 Byte | DPT.18 | CW |
| 84 | Output 4 | Disable scenes | 1 Bit | DPT.1 | CW |
| 85 | Output 4 | Upper limit position reached | 1 Bit | DPT.1 | CRT |
| 86 | Output 4 | Actual blind length | 1 Byte | DPT.5 | CRT |
| 87 | Output 4 | Actual slat position | 1 Byte | DPT.5 | CRT |
| 88 | Output 4 | Error | 1 Bit | DPT.1 | CRT |
| 89 | Output 5 | Up/Down move command | 1 Bit | DPT.1 | CW |
| 90 | Output 5 | Stop/Step move command | 1 Bit | DPT.1 | CW |
| 90 | Output 5 | Stop command | 1 Bit | DPT.1 | CW |
| 91 | Output 5 | Move to blind length manually | 1 Byte | DPT.5 | CW |
| 92 | Output 5 | Move to slat position manually | 1 Byte | DPT.5 | CW |
| 93 | Output 5 | Enable automatic objects | 1 Bit | DPT.1 | CW |
| 94 | Output 5 | Move to blind length automatically | 1 Byte | DPT.5 | CW |
| 95 | Output 5 | Move to slat position automatically | 1 Byte | DPT.5 | CW |
| 96 | Output 5 | Move to automatic position 1 | 1 Bit | DPT.1 | CW |
| 97 | Output 5 | Move to automatic position 2 | 1 Bit | DPT.1 | CW |
| 98 | Output 5 | Save automatic position 1 | 1 Bit | DPT.1 | CW |
| 99 | Output 5 | Save automatic position 2 | 1 Bit | DPT.1 | CW |
| 100 | Output 5 | Automatic position toggle | 1 Bit | DPT.1 | CW |
| 101 | Output 5 | Limitation of manual operation in automatic mode | 1 Bit | DPT.1 | CW |
| 102 | Output 5 | Dwell time active | 1 Bit | DPT.1 | CRT |
| 103 | Output 5 | Safety object C5 | 1 Bit | DPT.1 | CW |
| 104 | Output 5 | Disable object | 1 Bit | DPT.1 | CW |
| 105 | Output 5 | Scenes | 1 Byte | DPT.18 | CW |
| 106 | Output 5 | Disable scenes | 1 Bit | DPT.1 | CW |
| 107 | Output 5 | Upper limit position reached | 1 Bit | DPT.1 | CRT |
| 108 | Output 5 | Actual blind length | 1 Byte | DPT.5 | CRT |
| 109 | Output 5 | Actual slat position | 1 Byte | DPT.5 | CRT |
| 110 | Output 5 | Error | 1 Bit | DPT.1 | CRT |
| 111 | Output 6 | Up/Down move command | 1 Bit | DPT.1 | CW |
| 112 | Output 6 | Stop/Step move command | 1 Bit | DPT.1 | CW |
| 112 | Output 6 | Stop command | 1 Bit | DPT.1 | CW |
| 113 | Output 6 | Move to blind length manually | 1 Byte | DPT.5 | CW |
| 114 | Output 6 | Move to slat position manually | 1 Byte | DPT.5 | CW |
| 115 | Output 6 | Enable automatic objects | 1 Bit | DPT.1 | CW |
| 116 | Output 6 | Move to blind length automatically | 1 Byte | DPT.5 | CW |
| 117 | Output 6 | Move to slat position automatically | 1 Byte | DPT.5 | CW |
| 118 | Output 6 | Move to automatic position 1 | 1 Bit | DPT.1 | CW |
| 119 | Output 6 | Move to automatic position 2 | 1 Bit | DPT.1 | CW |
| 120 | Output 6 | Save automatic position 1 | 1 Bit | DPT.1 | CW |
| 121 | Output 6 | Save automatic position 2 | 1 Bit | DPT.1 | CW |
| 122 | Output 6 | Automatic position toggle | 1 Bit | DPT.1 | CW |
| 123 | Output 6 | Limitation of manual operation in automatic mode | 1 Bit | DPT.1 | CW |
| 124 | Output 6 | Dwell time active | 1 Bit | DPT.1 | CRT |
| 125 | Output 6 | Safety object C6 | 1 Bit | DPT.1 | CW |
| 126 | Output 6 | Disable object | 1 Bit | DPT.1 | CW |
| 127 | Output 6 | Scenes | 1 Byte | DPT.18 | CW |
| 128 | Output 6 | Disable scenes | 1 Bit | DPT.1 | CW |
| 129 | Output 6 | Upper limit position reached | 1 Bit | DPT.1 | CRT |
| 130 | Output 6 | Actual blind length | 1 Byte | DPT.5 | CRT |
| 131 | Output 6 | Actual slat position | 1 Byte | DPT.5 | CRT |
| 132 | Output 6 | Error | 1 Bit | DPT.1 | CRT |
| 133 | Output 7 | Up/Down move command | 1 Bit | DPT.1 | CW |
| 134 | Output 7 | Stop/Step move command | 1 Bit | DPT.1 | CW |
| 134 | Output 7 | Stop command | 1 Bit | DPT.1 | CW |
| 135 | Output 7 | Move to blind length manually | 1 Byte | DPT.5 | CW |
| 136 | Output 7 | Move to slat position manually | 1 Byte | DPT.5 | CW |
| 137 | Output 7 | Enable automatic objects | 1 Bit | DPT.1 | CW |
| 138 | Output 7 | Move to blind length automatically | 1 Byte | DPT.5 | CW |
| 139 | Output 7 | Move to slat position automatically | 1 Byte | DPT.5 | CW |
| 140 | Output 7 | Move to automatic position 1 | 1 Bit | DPT.1 | CW |
| 141 | Output 7 | Move to automatic position 2 | 1 Bit | DPT.1 | CW |
| 142 | Output 7 | Save automatic position 1 | 1 Bit | DPT.1 | CW |
| 143 | Output 7 | Save automatic position 2 | 1 Bit | DPT.1 | CW |
| 144 | Output 7 | Automatic position toggle | 1 Bit | DPT.1 | CW |
| 145 | Output 7 | Limitation of manual operation in automatic mode | 1 Bit | DPT.1 | CW |
| 146 | Output 7 | Dwell time active | 1 Bit | DPT.1 | CRT |
| 147 | Output 7 | Safety object C7 | 1 Bit | DPT.1 | CW |
| 148 | Output 7 | Disable object | 1 Bit | DPT.1 | CW |
| 149 | Output 7 | Scenes | 1 Byte | DPT.18 | CW |
| 150 | Output 7 | Disable scenes | 1 Bit | DPT.1 | CW |
| 151 | Output 7 | Upper limit position reached | 1 Bit | DPT.1 | CRT |
| 152 | Output 7 | Actual blind length | 1 Byte | DPT.5 | CRT |
| 153 | Output 7 | Actual slat position | 1 Byte | DPT.5 | CRT |
| 154 | Output 7 | Error | 1 Bit | DPT.1 | CRT |
| 155 | Output 8 | Up/Down move command | 1 Bit | DPT.1 | CW |
| 156 | Output 8 | Stop/Step move command | 1 Bit | DPT.1 | CW |
| 156 | Output 8 | Stop command | 1 Bit | DPT.1 | CW |
| 157 | Output 8 | Move to blind length manually | 1 Byte | DPT.5 | CW |
| 158 | Output 8 | Move to slat position manually | 1 Byte | DPT.5 | CW |
| 159 | Output 8 | Enable automatic objects | 1 Bit | DPT.1 | CW |
| 160 | Output 8 | Move to blind length automatically | 1 Byte | DPT.5 | CW |
| 161 | Output 8 | Move to slat position automatically | 1 Byte | DPT.5 | CW |
| 162 | Output 8 | Move to automatic position 1 | 1 Bit | DPT.1 | CW |
| 163 | Output 8 | Move to automatic position 2 | 1 Bit | DPT.1 | CW |
| 164 | Output 8 | Save automatic position 1 | 1 Bit | DPT.1 | CW |
| 165 | Output 8 | Save automatic position 2 | 1 Bit | DPT.1 | CW |
| 166 | Output 8 | Automatic position toggle | 1 Bit | DPT.1 | CW |
| 167 | Output 8 | Limitation of manual operation in automatic mode | 1 Bit | DPT.1 | CW |
| 168 | Output 8 | Dwell time active | 1 Bit | DPT.1 | CRT |
| 169 | Output 8 | Safety object C8 | 1 Bit | DPT.1 | CW |
| 170 | Output 8 | Disable object | 1 Bit | DPT.1 | CW |
| 171 | Output 8 | Scenes | 1 Byte | DPT.18 | CW |
| 172 | Output 8 | Disable scenes | 1 Bit | DPT.1 | CW |
| 173 | Output 8 | Upper limit position reached | 1 Bit | DPT.1 | CRT |
| 174 | Output 8 | Actual blind length | 1 Byte | DPT.5 | CRT |
| 175 | Output 8 | Actual slat position | 1 Byte | DPT.5 | CRT |
| 176 | Output 8 | Error | 1 Bit | DPT.1 | CRT |
| 177 | Output 9 | Up/Down move command | 1 Bit | DPT.1 | CW |
| 178 | Output 9 | Stop/Step move command | 1 Bit | DPT.1 | CW |
| 178 | Output 9 | Stop command | 1 Bit | DPT.1 | CW |
| 179 | Output 9 | Move to blind length manually | 1 Byte | DPT.5 | CW |
| 180 | Output 9 | Move to slat position manually | 1 Byte | DPT.5 | CW |
| 181 | Output 9 | Enable automatic objects | 1 Bit | DPT.1 | CW |
| 182 | Output 9 | Move to blind length automatically | 1 Byte | DPT.5 | CW |
| 183 | Output 9 | Move to slat position automatically | 1 Byte | DPT.5 | CW |
| 184 | Output 9 | Move to automatic position 1 | 1 Bit | DPT.1 | CW |
| 185 | Output 9 | Move to automatic position 2 | 1 Bit | DPT.1 | CW |
| 186 | Output 9 | Save automatic position 1 | 1 Bit | DPT.1 | CW |
| 187 | Output 9 | Save automatic position 2 | 1 Bit | DPT.1 | CW |
| 188 | Output 9 | Automatic position toggle | 1 Bit | DPT.1 | CW |
| 189 | Output 9 | Limitation of manual operation in automatic mode | 1 Bit | DPT.1 | CW |
| 190 | Output 9 | Dwell time active | 1 Bit | DPT.1 | CRT |
| 191 | Output 9 | Safety object C9 | 1 Bit | DPT.1 | CW |
| 192 | Output 9 | Disable object | 1 Bit | DPT.1 | CW |
| 193 | Output 9 | Scenes | 1 Byte | DPT.18 | CW |
| 194 | Output 9 | Disable scenes | 1 Bit | DPT.1 | CW |
| 195 | Output 9 | Upper limit position reached | 1 Bit | DPT.1 | CRT |
| 196 | Output 9 | Actual blind length | 1 Byte | DPT.5 | CRT |
| 197 | Output 9 | Actual slat position | 1 Byte | DPT.5 | CRT |
| 198 | Output 9 | Error | 1 Bit | DPT.1 | CRT |
| 199 | Output 10 | Up/Down move command | 1 Bit | DPT.1 | CW |
| 200 | Output 10 | Stop/Step move command | 1 Bit | DPT.1 | CW |
| 200 | Output 10 | Stop command | 1 Bit | DPT.1 | CW |
| 201 | Output 10 | Move to blind length manually | 1 Byte | DPT.5 | CW |
| 202 | Output 10 | Move to slat position manually | 1 Byte | DPT.5 | CW |
| 203 | Output 10 | Enable automatic objects | 1 Bit | DPT.1 | CW |
| 204 | Output 10 | Move to blind length automatically | 1 Byte | DPT.5 | CW |
| 205 | Output 10 | Move to slat position automatically | 1 Byte | DPT.5 | CW |
| 206 | Output 10 | Move to automatic position 1 | 1 Bit | DPT.1 | CW |
| 207 | Output 10 | Move to automatic position 2 | 1 Bit | DPT.1 | CW |
| 208 | Output 10 | Save automatic position 1 | 1 Bit | DPT.1 | CW |
| 209 | Output 10 | Save automatic position 2 | 1 Bit | DPT.1 | CW |
| 210 | Output 10 | Automatic position toggle | 1 Bit | DPT.1 | CW |
| 211 | Output 10 | Limitation of manual operation in automatic mode | 1 Bit | DPT.1 | CW |
| 212 | Output 10 | Dwell time active | 1 Bit | DPT.1 | CRT |
| 213 | Output 10 | Safety object C10 | 1 Bit | DPT.1 | CW |
| 214 | Output 10 | Disable object | 1 Bit | DPT.1 | CW |
| 215 | Output 10 | Scenes | 1 Byte | DPT.18 | CW |
| 216 | Output 10 | Disable scenes | 1 Bit | DPT.1 | CW |
| 217 | Output 10 | Upper limit position reached | 1 Bit | DPT.1 | CRT |
| 218 | Output 10 | Actual blind length | 1 Byte | DPT.5 | CRT |
| 219 | Output 10 | Actual slat position | 1 Byte | DPT.5 | CRT |
| 220 | Output 10 | Error | 1 Bit | DPT.1 | CRT |
| 221 | Output 11 | Up/Down move command | 1 Bit | DPT.1 | CW |
| 222 | Output 11 | Stop/Step move command | 1 Bit | DPT.1 | CW |
| 222 | Output 11 | Stop command | 1 Bit | DPT.1 | CW |
| 223 | Output 11 | Move to blind length manually | 1 Byte | DPT.5 | CW |
| 224 | Output 11 | Move to slat position manually | 1 Byte | DPT.5 | CW |
| 225 | Output 11 | Enable automatic objects | 1 Bit | DPT.1 | CW |
| 226 | Output 11 | Move to blind length automatically | 1 Byte | DPT.5 | CW |
| 227 | Output 11 | Move to slat position automatically | 1 Byte | DPT.5 | CW |
| 228 | Output 11 | Move to automatic position 1 | 1 Bit | DPT.1 | CW |
| 229 | Output 11 | Move to automatic position 2 | 1 Bit | DPT.1 | CW |
| 230 | Output 11 | Save automatic position 1 | 1 Bit | DPT.1 | CW |
| 231 | Output 11 | Save automatic position 2 | 1 Bit | DPT.1 | CW |
| 232 | Output 11 | Automatic position toggle | 1 Bit | DPT.1 | CW |
| 233 | Output 11 | Limitation of manual operation in automatic mode | 1 Bit | DPT.1 | CW |
| 234 | Output 11 | Dwell time active | 1 Bit | DPT.1 | CRT |
| 235 | Output 11 | Safety object C11 | 1 Bit | DPT.1 | CW |
| 236 | Output 11 | Disable object | 1 Bit | DPT.1 | CW |
| 237 | Output 11 | Scenes | 1 Byte | DPT.18 | CW |
| 238 | Output 11 | Disable scenes | 1 Bit | DPT.1 | CW |
| 239 | Output 11 | Upper limit position reached | 1 Bit | DPT.1 | CRT |
| 240 | Output 11 | Actual blind length | 1 Byte | DPT.5 | CRT |
| 241 | Output 11 | Actual slat position | 1 Byte | DPT.5 | CRT |
| 242 | Output 11 | Error | 1 Bit | DPT.1 | CRT |
| 243 | Output 12 | Up/Down move command | 1 Bit | DPT.1 | CW |
| 244 | Output 12 | Stop/Step move command | 1 Bit | DPT.1 | CW |
| 244 | Output 12 | Stop command | 1 Bit | DPT.1 | CW |
| 245 | Output 12 | Move to blind length manually | 1 Byte | DPT.5 | CW |
| 246 | Output 12 | Move to slat position manually | 1 Byte | DPT.5 | CW |
| 247 | Output 12 | Enable automatic objects | 1 Bit | DPT.1 | CW |
| 248 | Output 12 | Move to blind length automatically | 1 Byte | DPT.5 | CW |
| 249 | Output 12 | Move to slat position automatically | 1 Byte | DPT.5 | CW |
| 250 | Output 12 | Move to automatic position 1 | 1 Bit | DPT.1 | CW |
| 251 | Output 12 | Move to automatic position 2 | 1 Bit | DPT.1 | CW |
| 252 | Output 12 | Save automatic position 1 | 1 Bit | DPT.1 | CW |
| 253 | Output 12 | Save automatic position 2 | 1 Bit | DPT.1 | CW |
| 254 | Output 12 | Automatic position toggle | 1 Bit | DPT.1 | CW |
| 255 | Output 12 | Limitation of manual operation in automatic mode | 1 Bit | DPT.1 | CW |
| 256 | Output 12 | Dwell time active | 1 Bit | DPT.1 | CRT |
| 257 | Output 12 | Safety object C12 | 1 Bit | DPT.1 | CW |
| 258 | Output 12 | Disable object | 1 Bit | DPT.1 | CW |
| 259 | Output 12 | Scenes | 1 Byte | DPT.18 | CW |
| 260 | Output 12 | Disable scenes | 1 Bit | DPT.1 | CW |
| 261 | Output 12 | Upper limit position reached | 1 Bit | DPT.1 | CRT |
| 262 | Output 12 | Actual blind length | 1 Byte | DPT.5 | CRT |
| 263 | Output 12 | Actual slat position | 1 Byte | DPT.5 | CRT |
| 264 | Output 12 | Error | 1 Bit | DPT.1 | CRT |
| 265 | Output 13 | Up/Down move command | 1 Bit | DPT.1 | CW |
| 266 | Output 13 | Stop/Step move command | 1 Bit | DPT.1 | CW |
| 266 | Output 13 | Stop command | 1 Bit | DPT.1 | CW |
| 267 | Output 13 | Move to blind length manually | 1 Byte | DPT.5 | CW |
| 268 | Output 13 | Move to slat position manually | 1 Byte | DPT.5 | CW |
| 269 | Output 13 | Enable automatic objects | 1 Bit | DPT.1 | CW |
| 270 | Output 13 | Move to blind length automatically | 1 Byte | DPT.5 | CW |
| 271 | Output 13 | Move to slat position automatically | 1 Byte | DPT.5 | CW |
| 272 | Output 13 | Move to automatic position 1 | 1 Bit | DPT.1 | CW |
| 273 | Output 13 | Move to automatic position 2 | 1 Bit | DPT.1 | CW |
| 274 | Output 13 | Save automatic position 1 | 1 Bit | DPT.1 | CW |
| 275 | Output 13 | Save automatic position 2 | 1 Bit | DPT.1 | CW |
| 276 | Output 13 | Automatic position toggle | 1 Bit | DPT.1 | CW |
| 277 | Output 13 | Limitation of manual operation in automatic mode | 1 Bit | DPT.1 | CW |
| 278 | Output 13 | Dwell time active | 1 Bit | DPT.1 | CRT |
| 279 | Output 13 | Safety object C13 | 1 Bit | DPT.1 | CW |
| 280 | Output 13 | Disable object | 1 Bit | DPT.1 | CW |
| 281 | Output 13 | Scenes | 1 Byte | DPT.18 | CW |
| 282 | Output 13 | Disable scenes | 1 Bit | DPT.1 | CW |
| 283 | Output 13 | Upper limit position reached | 1 Bit | DPT.1 | CRT |
| 284 | Output 13 | Actual blind length | 1 Byte | DPT.5 | CRT |
| 285 | Output 13 | Actual slat position | 1 Byte | DPT.5 | CRT |
| 286 | Output 13 | Error | 1 Bit | DPT.1 | CRT |
| 287 | Output 14 | Up/Down move command | 1 Bit | DPT.1 | CW |
| 288 | Output 14 | Stop/Step move command | 1 Bit | DPT.1 | CW |
| 288 | Output 14 | Stop command | 1 Bit | DPT.1 | CW |
| 289 | Output 14 | Move to blind length manually | 1 Byte | DPT.5 | CW |
| 290 | Output 14 | Move to slat position manually | 1 Byte | DPT.5 | CW |
| 291 | Output 14 | Enable automatic objects | 1 Bit | DPT.1 | CW |
| 292 | Output 14 | Move to blind length automatically | 1 Byte | DPT.5 | CW |
| 293 | Output 14 | Move to slat position automatically | 1 Byte | DPT.5 | CW |
| 294 | Output 14 | Move to automatic position 1 | 1 Bit | DPT.1 | CW |
| 295 | Output 14 | Move to automatic position 2 | 1 Bit | DPT.1 | CW |
| 296 | Output 14 | Save automatic position 1 | 1 Bit | DPT.1 | CW |
| 297 | Output 14 | Save automatic position 2 | 1 Bit | DPT.1 | CW |
| 298 | Output 14 | Automatic position toggle | 1 Bit | DPT.1 | CW |
| 299 | Output 14 | Limitation of manual operation in automatic mode | 1 Bit | DPT.1 | CW |
| 300 | Output 14 | Dwell time active | 1 Bit | DPT.1 | CRT |
| 301 | Output 14 | Safety object C14 | 1 Bit | DPT.1 | CW |
| 302 | Output 14 | Disable object | 1 Bit | DPT.1 | CW |
| 303 | Output 14 | Scenes | 1 Byte | DPT.18 | CW |
| 304 | Output 14 | Disable scenes | 1 Bit | DPT.1 | CW |
| 305 | Output 14 | Upper limit position reached | 1 Bit | DPT.1 | CRT |
| 306 | Output 14 | Actual blind length | 1 Byte | DPT.5 | CRT |
| 307 | Output 14 | Actual slat position | 1 Byte | DPT.5 | CRT |
| 308 | Output 14 | Error | 1 Bit | DPT.1 | CRT |
| 309 | Output 15 | Up/Down move command | 1 Bit | DPT.1 | CW |
| 310 | Output 15 | Stop/Step move command | 1 Bit | DPT.1 | CW |
| 310 | Output 15 | Stop command | 1 Bit | DPT.1 | CW |
| 311 | Output 15 | Move to blind length manually | 1 Byte | DPT.5 | CW |
| 312 | Output 15 | Move to slat position manually | 1 Byte | DPT.5 | CW |
| 313 | Output 15 | Enable automatic objects | 1 Bit | DPT.1 | CW |
| 314 | Output 15 | Move to blind length automatically | 1 Byte | DPT.5 | CW |
| 315 | Output 15 | Move to slat position automatically | 1 Byte | DPT.5 | CW |
| 316 | Output 15 | Move to automatic position 1 | 1 Bit | DPT.1 | CW |
| 317 | Output 15 | Move to automatic position 2 | 1 Bit | DPT.1 | CW |
| 318 | Output 15 | Save automatic position 1 | 1 Bit | DPT.1 | CW |
| 319 | Output 15 | Save automatic position 2 | 1 Bit | DPT.1 | CW |
| 320 | Output 15 | Automatic position toggle | 1 Bit | DPT.1 | CW |
| 321 | Output 15 | Limitation of manual operation in automatic mode | 1 Bit | DPT.1 | CW |
| 322 | Output 15 | Dwell time active | 1 Bit | DPT.1 | CRT |
| 323 | Output 15 | Safety object C15 | 1 Bit | DPT.1 | CW |
| 324 | Output 15 | Disable object | 1 Bit | DPT.1 | CW |
| 325 | Output 15 | Scenes | 1 Byte | DPT.18 | CW |
| 326 | Output 15 | Disable scenes | 1 Bit | DPT.1 | CW |
| 327 | Output 15 | Upper limit position reached | 1 Bit | DPT.1 | CRT |
| 328 | Output 15 | Actual blind length | 1 Byte | DPT.5 | CRT |
| 329 | Output 15 | Actual slat position | 1 Byte | DPT.5 | CRT |
| 330 | Output 15 | Error | 1 Bit | DPT.1 | CRT |
| 331 | Output 16 | Up/Down move command | 1 Bit | DPT.1 | CW |
| 332 | Output 16 | Stop/Step move command | 1 Bit | DPT.1 | CW |
| 332 | Output 16 | Stop command | 1 Bit | DPT.1 | CW |
| 333 | Output 16 | Move to blind length manually | 1 Byte | DPT.5 | CW |
| 334 | Output 16 | Move to slat position manually | 1 Byte | DPT.5 | CW |
| 335 | Output 16 | Enable automatic objects | 1 Bit | DPT.1 | CW |
| 336 | Output 16 | Move to blind length automatically | 1 Byte | DPT.5 | CW |
| 337 | Output 16 | Move to slat position automatically | 1 Byte | DPT.5 | CW |
| 338 | Output 16 | Move to automatic position 1 | 1 Bit | DPT.1 | CW |
| 339 | Output 16 | Move to automatic position 2 | 1 Bit | DPT.1 | CW |
| 340 | Output 16 | Save automatic position 1 | 1 Bit | DPT.1 | CW |
| 341 | Output 16 | Save automatic position 2 | 1 Bit | DPT.1 | CW |
| 342 | Output 16 | Automatic position toggle | 1 Bit | DPT.1 | CW |
| 343 | Output 16 | Limitation of manual operation in automatic mode | 1 Bit | DPT.1 | CW |
| 344 | Output 16 | Dwell time active | 1 Bit | DPT.1 | CRT |
| 345 | Output 16 | Safety object C16 | 1 Bit | DPT.1 | CW |
| 346 | Output 16 | Disable object | 1 Bit | DPT.1 | CW |
| 347 | Output 16 | Scenes | 1 Byte | DPT.18 | CW |
| 348 | Output 16 | Disable scenes | 1 Bit | DPT.1 | CW |
| 349 | Output 16 | Upper limit position reached | 1 Bit | DPT.1 | CRT |
| 350 | Output 16 | Actual blind length | 1 Byte | DPT.5 | CRT |
| 351 | Output 16 | Actual slat position | 1 Byte | DPT.5 | CRT |
| 352 | Output 16 | Error | 1 Bit | DPT.1 | CRT |
| 353 | Input 1 | Up/Down move command | 1 Bit | DPT.1 | CT |
| 353 | Input 1 | On/Off/Toggle 1.1 | 1 Bit | DPT.1 | CWT |
| 353 | Input 1 | Sensor 1.1 | 1 Byte | DPT.5 | CT |
| 353 | Input 1 | Scene 1.1 | 1 Byte | DPT.18 | CT |
| 354 | Input 1 | Stop/Step move command | 1 Bit | DPT.1 | CT |
| 354 | Input 1 | On/Off/Toggle 1.2 | 1 Bit | DPT.1 | CWT |
| 354 | Input 1 | Sensor 1.2 | 1 Byte | DPT.5 | CT |
| 354 | Input 1 | Scene 1.2 | 1 Byte | DPT.18 | CT |
| 355 | Input 1 | Enable | 1 Bit | DPT.1 | CW |
| 356 | Input 2 | Up/Down move command | 1 Bit | DPT.1 | CT |
| 356 | Input 2 | On/Off/Toggle 2.1 | 1 Bit | DPT.1 | CWT |
| 356 | Input 2 | Sensor 2.1 | 1 Byte | DPT.5 | CT |
| 356 | Input 2 | Scene 2.1 | 1 Byte | DPT.18 | CT |
| 357 | Input 2 | Stop/Step move command | 1 Bit | DPT.1 | CT |
| 357 | Input 2 | On/Off/Toggle 2.2 | 1 Bit | DPT.1 | CWT |
| 357 | Input 2 | Sensor 2.2 | 1 Byte | DPT.5 | CT |
| 357 | Input 2 | Scene 2.2 | 1 Byte | DPT.18 | CT |
| 358 | Input 2 | Enable | 1 Bit | DPT.1 | CW |
| 359 | Input 3 | Up/Down move command | 1 Bit | DPT.1 | CT |
| 359 | Input 3 | On/Off/Toggle 3.1 | 1 Bit | DPT.1 | CWT |
| 359 | Input 3 | Sensor 3.1 | 1 Byte | DPT.5 | CT |
| 359 | Input 3 | Scene 3.1 | 1 Byte | DPT.18 | CT |
| 360 | Input 3 | Stop/Step move command | 1 Bit | DPT.1 | CT |
| 360 | Input 3 | On/Off/Toggle 3.2 | 1 Bit | DPT.1 | CWT |
| 360 | Input 3 | Sensor 3.2 | 1 Byte | DPT.5 | CT |
| 360 | Input 3 | Scene 3.2 | 1 Byte | DPT.18 | CT |
| 361 | Input 3 | Enable | 1 Bit | DPT.1 | CW |
| 362 | Input 4 | Up/Down move command | 1 Bit | DPT.1 | CT |
| 362 | Input 4 | On/Off/Toggle 4.1 | 1 Bit | DPT.1 | CWT |
| 362 | Input 4 | Sensor 4.1 | 1 Byte | DPT.5 | CT |
| 362 | Input 4 | Scene 4.1 | 1 Byte | DPT.18 | CT |
| 363 | Input 4 | Stop/Step move command | 1 Bit | DPT.1 | CT |
| 363 | Input 4 | On/Off/Toggle 4.2 | 1 Bit | DPT.1 | CWT |
| 363 | Input 4 | Sensor 4.2 | 1 Byte | DPT.5 | CT |
| 363 | Input 4 | Scene 4.2 | 1 Byte | DPT.18 | CT |
| 364 | Input 4 | Enable | 1 Bit | DPT.1 | CW |
| 365 | Input 5 | Up/Down move command | 1 Bit | DPT.1 | CT |
| 365 | Input 5 | On/Off/Toggle 5.1 | 1 Bit | DPT.1 | CWT |
| 365 | Input 5 | Sensor 5.1 | 1 Byte | DPT.5 | CT |
| 365 | Input 5 | Scene 5.1 | 1 Byte | DPT.18 | CT |
| 366 | Input 5 | Stop/Step move command | 1 Bit | DPT.1 | CT |
| 366 | Input 5 | On/Off/Toggle 5.2 | 1 Bit | DPT.1 | CWT |
| 366 | Input 5 | Sensor 5.2 | 1 Byte | DPT.5 | CT |
| 366 | Input 5 | Scene 5.2 | 1 Byte | DPT.18 | CT |
| 367 | Input 5 | Enable | 1 Bit | DPT.1 | CW |
| 368 | Input 6 | Up/Down move command | 1 Bit | DPT.1 | CT |
| 368 | Input 6 | On/Off/Toggle 6.1 | 1 Bit | DPT.1 | CWT |
| 368 | Input 6 | Sensor 6.1 | 1 Byte | DPT.5 | CT |
| 368 | Input 6 | Scene 6.1 | 1 Byte | DPT.18 | CT |
| 369 | Input 6 | Stop/Step move command | 1 Bit | DPT.1 | CT |
| 369 | Input 6 | On/Off/Toggle 6.2 | 1 Bit | DPT.1 | CWT |
| 369 | Input 6 | Sensor 6.2 | 1 Byte | DPT.5 | CT |
| 369 | Input 6 | Scene 6.2 | 1 Byte | DPT.18 | CT |
| 370 | Input 6 | Enable | 1 Bit | DPT.1 | CW |
| 371 | Input 7 | Up/Down move command | 1 Bit | DPT.1 | CT |
| 371 | Input 7 | On/Off/Toggle 7.1 | 1 Bit | DPT.1 | CWT |
| 371 | Input 7 | Sensor 7.1 | 1 Byte | DPT.5 | CT |
| 371 | Input 7 | Scene 7.1 | 1 Byte | DPT.18 | CT |
| 372 | Input 7 | Stop/Step move command | 1 Bit | DPT.1 | CT |
| 372 | Input 7 | On/Off/Toggle 7.2 | 1 Bit | DPT.1 | CWT |
| 372 | Input 7 | Sensor 7.2 | 1 Byte | DPT.5 | CT |
| 372 | Input 7 | Scene 7.2 | 1 Byte | DPT.18 | CT |
| 373 | Input 7 | Enable | 1 Bit | DPT.1 | CW |
| 374 | Input 8 | Up/Down move command | 1 Bit | DPT.1 | CT |
| 374 | Input 8 | On/Off/Toggle 8.1 | 1 Bit | DPT.1 | CWT |
| 374 | Input 8 | Sensor 8.1 | 1 Byte | DPT.5 | CT |
| 374 | Input 8 | Scene 8.1 | 1 Byte | DPT.18 | CT |
| 375 | Input 8 | Stop/Step move command | 1 Bit | DPT.1 | CT |
| 375 | Input 8 | On/Off/Toggle 8.2 | 1 Bit | DPT.1 | CWT |
| 375 | Input 8 | Sensor 8.2 | 1 Byte | DPT.5 | CT |
| 375 | Input 8 | Scene 8.2 | 1 Byte | DPT.18 | CT |
| 376 | Input 8 | Enable | 1 Bit | DPT.1 | CW |
| 377 | Input 9 | Up/Down move command | 1 Bit | DPT.1 | CT |
| 377 | Input 9 | On/Off/Toggle 9.1 | 1 Bit | DPT.1 | CWT |
| 377 | Input 9 | Sensor 9.1 | 1 Byte | DPT.5 | CT |
| 377 | Input 9 | Scene 9.1 | 1 Byte | DPT.18 | CT |
| 378 | Input 9 | Stop/Step move command | 1 Bit | DPT.1 | CT |
| 378 | Input 9 | On/Off/Toggle 9.2 | 1 Bit | DPT.1 | CWT |
| 378 | Input 9 | Sensor 9.2 | 1 Byte | DPT.5 | CT |
| 378 | Input 9 | Scene 9.2 | 1 Byte | DPT.18 | CT |
| 379 | Input 9 | Enable | 1 Bit | DPT.1 | CW |
| 380 | Input 10 | Up/Down move command | 1 Bit | DPT.1 | CT |
| 380 | Input 10 | On/Off/Toggle 10.1 | 1 Bit | DPT.1 | CWT |
| 380 | Input 10 | Sensor 10.1 | 1 Byte | DPT.5 | CT |
| 380 | Input 10 | Scene 10.1 | 1 Byte | DPT.18 | CT |
| 381 | Input 10 | Stop/Step move command | 1 Bit | DPT.1 | CT |
| 381 | Input 10 | On/Off/Toggle 10.2 | 1 Bit | DPT.1 | CWT |
| 381 | Input 10 | Sensor 10.2 | 1 Byte | DPT.5 | CT |
| 381 | Input 10 | Scene 10.2 | 1 Byte | DPT.18 | CT |
| 382 | Input 10 | Enable | 1 Bit | DPT.1 | CW |
| 383 | Input 11 | Up/Down move command | 1 Bit | DPT.1 | CT |
| 383 | Input 11 | On/Off/Toggle 11.1 | 1 Bit | DPT.1 | CWT |
| 383 | Input 11 | Sensor 11.1 | 1 Byte | DPT.5 | CT |
| 383 | Input 11 | Scene 11.1 | 1 Byte | DPT.18 | CT |
| 384 | Input 11 | Stop/Step move command | 1 Bit | DPT.1 | CT |
| 384 | Input 11 | On/Off/Toggle 11.2 | 1 Bit | DPT.1 | CWT |
| 384 | Input 11 | Sensor 11.2 | 1 Byte | DPT.5 | CT |
| 384 | Input 11 | Scene 11.2 | 1 Byte | DPT.18 | CT |
| 385 | Input 11 | Enable | 1 Bit | DPT.1 | CW |
| 386 | Input 12 | Up/Down move command | 1 Bit | DPT.1 | CT |
| 386 | Input 12 | On/Off/Toggle 12.1 | 1 Bit | DPT.1 | CWT |
| 386 | Input 12 | Sensor 12.1 | 1 Byte | DPT.5 | CT |
| 386 | Input 12 | Scene 12.1 | 1 Byte | DPT.18 | CT |
| 387 | Input 12 | Stop/Step move command | 1 Bit | DPT.1 | CT |
| 387 | Input 12 | On/Off/Toggle 12.2 | 1 Bit | DPT.1 | CWT |
| 387 | Input 12 | Sensor 12.2 | 1 Byte | DPT.5 | CT |
| 387 | Input 12 | Scene 12.2 | 1 Byte | DPT.18 | CT |
| 388 | Input 12 | Enable | 1 Bit | DPT.1 | CW |
| 389 | Input 13 | Up/Down move command | 1 Bit | DPT.1 | CT |
| 389 | Input 13 | On/Off/Toggle 13.1 | 1 Bit | DPT.1 | CWT |
| 389 | Input 13 | Sensor 13.1 | 1 Byte | DPT.5 | CT |
| 389 | Input 13 | Scene 13.1 | 1 Byte | DPT.18 | CT |
| 390 | Input 13 | Stop/Step move command | 1 Bit | DPT.1 | CT |
| 390 | Input 13 | On/Off/Toggle 13.2 | 1 Bit | DPT.1 | CWT |
| 390 | Input 13 | Sensor 13.2 | 1 Byte | DPT.5 | CT |
| 390 | Input 13 | Scene 13.2 | 1 Byte | DPT.18 | CT |
| 391 | Input 13 | Enable | 1 Bit | DPT.1 | CW |
| 392 | Input 14 | Up/Down move command | 1 Bit | DPT.1 | CT |
| 392 | Input 14 | On/Off/Toggle 14.1 | 1 Bit | DPT.1 | CWT |
| 392 | Input 14 | Sensor 14.1 | 1 Byte | DPT.5 | CT |
| 392 | Input 14 | Scene 14.1 | 1 Byte | DPT.18 | CT |
| 393 | Input 14 | Stop/Step move command | 1 Bit | DPT.1 | CT |
| 393 | Input 14 | On/Off/Toggle 14.2 | 1 Bit | DPT.1 | CWT |
| 393 | Input 14 | Sensor 14.2 | 1 Byte | DPT.5 | CT |
| 393 | Input 14 | Scene 14.2 | 1 Byte | DPT.18 | CT |
| 394 | Input 14 | Enable | 1 Bit | DPT.1 | CW |
| 395 | Input 15 | Up/Down move command | 1 Bit | DPT.1 | CT |
| 395 | Input 15 | On/Off/Toggle 15.1 | 1 Bit | DPT.1 | CWT |
| 395 | Input 15 | Sensor 15.1 | 1 Byte | DPT.5 | CT |
| 395 | Input 15 | Scene 15.1 | 1 Byte | DPT.18 | CT |
| 396 | Input 15 | Stop/Step move command | 1 Bit | DPT.1 | CT |
| 396 | Input 15 | On/Off/Toggle 15.2 | 1 Bit | DPT.1 | CWT |
| 396 | Input 15 | Sensor 15.2 | 1 Byte | DPT.5 | CT |
| 396 | Input 15 | Scene 15.2 | 1 Byte | DPT.18 | CT |
| 397 | Input 15 | Enable | 1 Bit | DPT.1 | CW |
| 398 | Input 16 | Up/Down move command | 1 Bit | DPT.1 | CT |
| 398 | Input 16 | On/Off/Toggle 16.1 | 1 Bit | DPT.1 | CWT |
| 398 | Input 16 | Sensor 16.1 | 1 Byte | DPT.5 | CT |
| 398 | Input 16 | Scene 16.1 | 1 Byte | DPT.18 | CT |
| 399 | Input 16 | Stop/Step move command | 1 Bit | DPT.1 | CT |
| 399 | Input 16 | On/Off/Toggle 16.2 | 1 Bit | DPT.1 | CWT |
| 399 | Input 16 | Sensor 16.2 | 1 Byte | DPT.5 | CT |
| 399 | Input 16 | Scene 16.2 | 1 Byte | DPT.18 | CT |
| 400 | Input 16 | Enable | 1 Bit | DPT.1 | CW |
| 401 | All outputs | Errors central | 1 Bit | DPT.1 | CRT |
| 402 | All outputs | Errors central text | 14 Bytes | DPT.16 | CRT |
| 403 | All outputs | Errors clear | 1 Bit | DPT.1 | CW |
| 420 | All Outputs | Safety object A | 1 Bit | DPT.1 | CW |
| 421 | All Outputs | Safety object B | 1 Bit | DPT.1 | CW |
| 422 | All Outputs | Safety object D | 1 Bit | DPT.1 | CW |
| 423 | Device | Actuator available | 1 Bit | DPT.1 | CRT |
Parameters (313)
| Parameter | Type | Default |
|---|---|---|
| Send and switch delay time | list | Startup Delay after Boot |
| Maximum telegram rate | list | Restriction off |
| Bluetooth visible | list | ON |
| Bluetooth | list | On |
| Bluetooth Login Key | unsignedInt 0…9999 | 3706 |
| Object "Actuator available" | list | No |
| Time for cyclic sending [hh:mm:ss] | time | 300 |
| Object value | list | 1 |
| PID_HARDWARE_TYPE_PARAMETER | list | |
| Kanal Ausgang 1 sichtbar | list | ON |
| Kanal Ausgang 2 sichtbar | list | ON |
| Kanal Ausgang 3 sichtbar | list | ON |
| Kanal Ausgang 4 sichtbar | list | ON |
| Kanal Ausgang 5 sichtbar | list | ON |
| Kanal Ausgang 6 sichtbar | list | ON |
| Kanal Ausgang 7 sichtbar | list | ON |
| Kanal Ausgang 8 sichtbar | list | ON |
| Kanal Ausgang 9 sichtbar | list | ON |
| Kanal Ausgang 10 sichtbar | list | ON |
| Kanal Ausgang 11 sichtbar | list | ON |
| Kanal Ausgang 12 sichtbar | list | ON |
| Kanal Ausgang 13 sichtbar | list | ON |
| Kanal Ausgang 14 sichtbar | list | ON |
| Kanal Ausgang 15 sichtbar | list | ON |
| Kanal Ausgang 16 sichtbar | list | ON |
| Kanal Eingang 1 sichtbar | list | OFF |
| Kanal Eingang 2 sichtbar | list | OFF |
| Kanal Eingang 3 sichtbar | list | OFF |
| Kanal Eingang 4 sichtbar | list | OFF |
| Kanal Eingang 5 sichtbar | list | OFF |
| Kanal Eingang 6 sichtbar | list | OFF |
| Kanal Eingang 7 sichtbar | list | OFF |
| Kanal Eingang 8 sichtbar | list | OFF |
| Kanal Eingang 9 sichtbar | list | OFF |
| Kanal Eingang 10 sichtbar | list | OFF |
| Kanal Eingang 11 sichtbar | list | OFF |
| Kanal Eingang 12 sichtbar | list | OFF |
| Kanal Eingang 13 sichtbar | list | OFF |
| Kanal Eingang 14 sichtbar | list | OFF |
| Kanal Eingang 15 sichtbar | list | OFF |
| Kanal Eingang 16 sichtbar | list | OFF |
| Activate power saving mode | list | No |
| On delay [ms] | unsignedInt 0…2550 | 500 |
| Off delay [min] | unsignedInt 1…255 | 255 |
| Minimum off time [s] | unsignedInt 1…15 | 15 |
| Text error: | text | Error |
| Text no error: | text | No error |
| Cyclic sending of error Objects | list | No |
| Transfer data from motor list to actuator | list | No |
| Motor 1 - Manufacturer-ID [decimal] | list | Not used |
| Motor 1 - ID [decimal] | unsignedInt 0…4294967295 | 0 |
| Motor 1 - Alias name | text | |
| Motor 1 - Installation location | text | |
| Motor 1 - Comment | text | |
| Motor 1 - Allocation | list | No allocation |
| Motor 1 - Reference motor | list | No |
| Motor 2 - Manufacturer-ID [decimal] | list | Not used |
| Motor 2 - ID [decimal] | unsignedInt 0…4294967295 | 0 |
| Motor 2 - Alias name | text | |
| Motor 2 - Installation location | text | |
| Motor 2 - Comment | text | |
| Motor 2 - Allocation | list | No allocation |
| Motor 2 - Reference motor | list | No |
| Motor 3 - Manufacturer-ID [decimal] | list | Not used |
| Motor 3 - ID [decimal] | unsignedInt 0…4294967295 | 0 |
| Motor 3 - Alias name | text | |
| Motor 3 - Installation location | text | |
| Motor 3 - Comment | text | |
| Motor 3 - Allocation | list | No allocation |
| Motor 3 - Reference motor | list | No |
| Motor 4 - Manufacturer-ID [decimal] | list | Not used |
| Motor 4 - ID [decimal] | unsignedInt 0…4294967295 | 0 |
| Motor 4 - Alias name | text | |
| Motor 4 - Installation location | text | |
| Motor 4 - Comment | text | |
| Motor 4 - Allocation | list | No allocation |
| Motor 4 - Reference motor | list | No |
| Motor 5 - Manufacturer-ID [decimal] | list | Not used |
| Motor 5 - ID [decimal] | unsignedInt 0…4294967295 | 0 |
| Motor 5 - Alias name | text | |
| Motor 5 - Installation location | text | |
| Motor 5 - Comment | text | |
| Motor 5 - Allocation | list | No allocation |
| Motor 5 - Reference motor | list | No |
| Motor 6 - Manufacturer-ID [decimal] | list | Not used |
| Motor 6 - ID [decimal] | unsignedInt 0…4294967295 | 0 |
| Motor 6 - Alias name | text | |
| Motor 6 - Installation location | text | |
| Motor 6 - Comment | text | |
| Motor 6 - Allocation | list | No allocation |
| Motor 6 - Reference motor | list | No |
| Motor 7 - Manufacturer-ID [decimal] | list | Not used |
| Motor 7 - ID [decimal] | unsignedInt 0…4294967295 | 0 |
| Motor 7 - Alias name | text | |
| Motor 7 - Installation location | text | |
| Motor 7 - Comment | text | |
| Motor 7 - Allocation | list | No allocation |
| Motor 7 - Reference motor | list | No |
| Motor 8 - Manufacturer-ID [decimal] | list | Not used |
| Motor 8 - ID [decimal] | unsignedInt 0…4294967295 | 0 |
| Motor 8 - Alias name | text | |
| Motor 8 - Installation location | text | |
| Motor 8 - Comment | text | |
| Motor 8 - Allocation | list | No allocation |
| Motor 8 - Reference motor | list | No |
| Motor 9 - Manufacturer-ID [decimal] | list | Not used |
| Motor 9 - ID [decimal] | unsignedInt 0…4294967295 | 0 |
| Motor 9 - Alias name | text | |
| Motor 9 - Installation location | text | |
| Motor 9 - Comment | text | |
| Motor 9 - Allocation | list | No allocation |
| Motor 9 - Reference motor | list | No |
| Motor 10 - Manufacturer-ID [decimal] | list | Not used |
| Motor 10 - ID [decimal] | unsignedInt 0…4294967295 | 0 |
| Motor 10 - Alias name | text | |
| Motor 10 - Installation location | text | |
| Motor 10 - Comment | text | |
| Motor 10 - Allocation | list | No allocation |
| Motor 10 - Reference motor | list | No |
| Motor 11 - Manufacturer-ID [decimal] | list | Not used |
| Motor 11 - ID [decimal] | unsignedInt 0…4294967295 | 0 |
| Motor 11 - Alias name | text | |
| Motor 11 - Installation location | text | |
| Motor 11 - Comment | text | |
| Motor 11 - Allocation | list | No allocation |
| Motor 11 - Reference motor | list | No |
| Motor 12 - Manufacturer-ID [decimal] | list | Not used |
| Motor 12 - ID [decimal] | unsignedInt 0…4294967295 | 0 |
| Motor 12 - Alias name | text | |
| Motor 12 - Installation location | text | |
| Motor 12 - Comment | text | |
| Motor 12 - Allocation | list | No allocation |
| Motor 12 - Reference motor | list | No |
| Motor 13 - Manufacturer-ID [decimal] | list | Not used |
| Motor 13 - ID [decimal] | unsignedInt 0…4294967295 | 0 |
| Motor 13 - Alias name | text | |
| Motor 13 - Installation location | text | |
| Motor 13 - Comment | text | |
| Motor 13 - Allocation | list | No allocation |
| Motor 13 - Reference motor | list | No |
| Motor 14 - Manufacturer-ID [decimal] | list | Not used |
| Motor 14 - ID [decimal] | unsignedInt 0…4294967295 | 0 |
| Motor 14 - Alias name | text | |
| Motor 14 - Installation location | text | |
| Motor 14 - Comment | text | |
| Motor 14 - Allocation | list | No allocation |
| Motor 14 - Reference motor | list | No |
| Motor 15 - Manufacturer-ID [decimal] | list | Not used |
| Motor 15 - ID [decimal] | unsignedInt 0…4294967295 | 0 |
| Motor 15 - Alias name | text | |
| Motor 15 - Installation location | text | |
| Motor 15 - Comment | text | |
| Motor 15 - Allocation | list | No allocation |
| Motor 15 - Reference motor | list | No |
| Motor 16 - Manufacturer-ID [decimal] | list | Not used |
| Motor 16 - ID [decimal] | unsignedInt 0…4294967295 | 0 |
| Motor 16 - Alias name | text | |
| Motor 16 - Installation location | text | |
| Motor 16 - Comment | text | |
| Motor 16 - Allocation | list | No allocation |
| Motor 16 - Reference motor | list | No |
| Identical settings for all outputs | list | On |
| Operating mode of output 1 | list | Not used |
| Operating mode of output 2 | list | Not used |
| Operating mode of output 3 | list | Not used |
| Operating mode of output 4 | list | Not used |
| Operating mode of output 5 | list | Not used |
| Operating mode of output 6 | list | Not used |
| Operating mode of output 7 | list | Not used |
| Operating mode of output 8 | list | Not used |
| Operating mode of output 9 | list | Not used |
| Operating mode of output 10 | list | Not used |
| Operating mode of output 11 | list | Not used |
| Operating mode of output 12 | list | Not used |
| Operating mode of output 13 | list | Not used |
| Operating mode of output 14 | list | Not used |
| Operating mode of output 15 | list | Not used |
| Operating mode of output 16 | list | Not used |
| Operating mode of outputs 1 - 16 | list | Not used |
| Update of the status objects | list | After movement |
| Time-offset output actuation | list | Disabled |
| Overwrite scene memory when programming | list | On |
| Object "upper limit position reached" | list | 1 = upper limit |
| Tilting length [Impulses] | unsignedInt 0…65535 | 160 |
| Slat tilting by step command [%] | unsignedInt 0…100 | 15 |
| Slat position after downward movement [%] | unsignedInt 0…100 | 70 |
| Limit switch for calibration | list | Upper and lower limit switch |
| Limit position offset imp. top [Impulses] | unsignedInt 0…65000 | 0 |
| Limit position offset imp. botton [Impulses] | unsignedInt 0…65000 | 0 |
| Minimum movement time [Impulses] | unsignedInt 0…65535 | 5 |
| Position tolerance impulses [Impulses] | unsignedInt 0…65535 | 2000 |
| Lash as changes of direction [Impulses] | unsignedInt 0…255 | 0 |
| Monitoring time for disable object | list | Cyclical monitoring off |
| Behaviour when alarm active through safety object A | list | Up |
| Blind length [%] | unsignedInt 0…100 | 0 |
| Slat position [%] | unsignedInt 0…100 | 0 |
| Behaviour when alarm ends through safety object A | list | Restore automatic/manual/scene |
| Behaviour when alarm active through safety object B | list | Up |
| Behaviour when alarm ends through safety object B | list | Restore automatic/manual/scene |
| Behaviour when alarm active through safety object C1 | list | Up |
| Behaviour when alarm ends through safety object C1 | list | Restore automatic/manual/scene |
| Behaviour when alarm active through safety object D | list | Up |
| Behaviour when alarm ends through safety object D | list | Restore automatic/manual/scene |
| Behaviour after a bus voltage failure | list | No reaction |
| Behaviour after bus or mains voltage return | list | No reaction |
| Scene 1 | text | Scene 1 |
| Scene | list | Do not use |
| Scene number | unsignedInt 1…64 | 1 |
| Storage via telegram permitted | list | Yes |
| Scene 2 | text | Scene 2 |
| Scene number | unsignedInt 1…64 | 2 |
| Scene 3 | text | Scene 3 |
| Scene number | unsignedInt 1…64 | 3 |
| Scene 4 | text | Scene 4 |
| Scene number | unsignedInt 1…64 | 4 |
| Scene 5 | text | Scene 5 |
| Scene number | unsignedInt 1…64 | 5 |
| Scene 6 | text | Scene 6 |
| Scene number | unsignedInt 1…64 | 6 |
| Scene 7 | text | Scene 7 |
| Scene number | unsignedInt 1…64 | 7 |
| Scene 8 | text | Scene 8 |
| Scene number | unsignedInt 1…64 | 8 |
| Use automatic objects | list | No |
| Use automatic positions 1 and 2 | list | No |
| Automatic delay after manual operation [hh:mm] | time | 0 |
| Behaviour after expiry of automatic delay | list | Perform last automatic object |
| Object "Dwell time active" | list | 1 = active |
| Limitation of manual operation if object "Limitation of manual operation in automatic mode" = 1 | list | Disable manual operation and scenes |
| Min. blind length | list | From automatic blind length object |
| Min. blind length [%] | unsignedInt 0…100 | 0 |
| Max. blind length | list | No restriction |
| Max. blind length [%] | unsignedInt 0…100 | 100 |
| Min. slat angle | list | From automatic slat angle object |
| Min. slat angle [%] | unsignedInt 0…100 | 0 |
| Max. slat angle | list | No restriction |
| Max. slat angle [%] | unsignedInt 0…100 | 100 |
| Automatic position 1 blind length [%] | unsignedInt 0…100 | 100 |
| Automatic position 1 slat position [%] | unsignedInt 0…100 | 70 |
| Automatic position 2 blind length [%] | unsignedInt 0…100 | 50 |
| Automatic position 2 slat position [%] | unsignedInt 0…100 | 70 |
| Position toggle delay time [hh:mm] | time | 180 |
| Save positions 1+2 via telegram | list | Off |
| Overwrite positions saved on-site when programming | list | Off |
| Minimum move impulses [Impulses] | unsignedInt 0…65535 | 5 |
| Behaviour when alarm active through safety object C2 | list | Up |
| Behaviour when alarm ends through safety object C2 | list | Restore automatic/manual/scene |
| Behaviour when alarm active through safety object C3 | list | Up |
| Behaviour when alarm ends through safety object C3 | list | Restore automatic/manual/scene |
| Behaviour when alarm active through safety object C4 | list | Up |
| Behaviour when alarm ends through safety object C4 | list | Restore automatic/manual/scene |
| Behaviour when alarm active through safety object C5 | list | Up |
| Behaviour when alarm ends through safety object C5 | list | Restore automatic/manual/scene |
| Behaviour when alarm active through safety object C6 | list | Up |
| Behaviour when alarm ends through safety object C6 | list | Restore automatic/manual/scene |
| Behaviour when alarm active through safety object C7 | list | Up |
| Behaviour when alarm ends through safety object C7 | list | Restore automatic/manual/scene |
| Behaviour when alarm active through safety object C8 | list | Up |
| Behaviour when alarm ends through safety object C8 | list | Restore automatic/manual/scene |
| Behaviour when alarm active through safety object C9 | list | Up |
| Behaviour when alarm ends through safety object C9 | list | Restore automatic/manual/scene |
| Behaviour when alarm active through safety object C10 | list | Up |
| Behaviour when alarm ends through safety object C10 | list | Restore automatic/manual/scene |
| Behaviour when alarm active through safety object C11 | list | Up |
| Behaviour when alarm ends through safety object C11 | list | Restore automatic/manual/scene |
| Behaviour when alarm active through safety object C12 | list | Up |
| Behaviour when alarm ends through safety object C12 | list | Restore automatic/manual/scene |
| Behaviour when alarm active through safety object C13 | list | Up |
| Behaviour when alarm ends through safety object C13 | list | Restore automatic/manual/scene |
| Behaviour when alarm active through safety object C14 | list | Up |
| Behaviour when alarm ends through safety object C14 | list | Restore automatic/manual/scene |
| Behaviour when alarm active through safety object C15 | list | Up |
| Behaviour when alarm ends through safety object C15 | list | Restore automatic/manual/scene |
| Behaviour when alarm active through safety object C16 | list | Up |
| Behaviour when alarm ends through safety object C16 | list | Restore automatic/manual/scene |
| Behaviour when alarm active through safety object C1 - C16 | list | Up |
| Behaviour when alarm ends through safety object C1 - C16 | list | Restore automatic/manual/scene |
| Kanal für Inputs sichtbar | list | OFF |
| Operating mode of inputs 1.1/1.2 | list | Not used |
| Operating mode of inputs 2.1/2.2 | list | Not used |
| Operating mode of inputs 3.1/3.2 | list | Not used |
| Operating mode of inputs 4.1/4.2 | list | Not used |
| Operating mode of inputs 5.1/5.2 | list | Not used |
| Operating mode of inputs 6.1/6.2 | list | Not used |
| Operating mode of inputs 7.1/7.2 | list | Not used |
| Operating mode of inputs 8.1/8.2 | list | Not used |
| Operating mode of inputs 9.1/9.2 | list | Not used |
| Operating mode of inputs 10.1/10.2 | list | Not used |
| Operating mode of inputs 11.1/11.2 | list | Not used |
| Operating mode of inputs 12.1/12.2 | list | Not used |
| Operating mode of inputs 13.1/13.2 | list | Not used |
| Operating mode of inputs 14.1/14.2 | list | Not used |
| Operating mode of inputs 15.1/15.2 | list | Not used |
| Operating mode of inputs 16.1/16.2 | list | Not used |
| Delay after a bus voltage return [seconds] | unsignedInt 3…255 | 3 |
| Input signal is interpreted as long after | list | 1.0 seconds |
| Telegram after a short press of the button | list | Stop/Step move command |
| Telegram after a long press of the button | list | Up/Down move command |
| Time for cyclic sending [hh:mm:ss] | time | 0 |
| Interchange up and down input | list | No |
| Telegram after rising edge | list | Toggle |
| Telegram after falling edge | list | No function |
| Telegram after the bus or mains voltage returns | list | Do not send value |
| Send Behaviour | list | Send value at both edges |
| Telegram after rising edge | unsignedInt 0…255 | 128 |
| Telegram after falling edge | unsignedInt 0…255 | 128 |
| Scenes number | unsignedInt 1…64 | 1 |
| Telegram after a short press of the button | list | Execute scene |
| Telegram after a long press of the button | list | No function |
| Cyclic monitoring | list | Cyclical monitoring off |
| Behaviour when the bus or mains voltage returns | list | Deactivate alarm |
| Behaviour in case of bus voltage failure | list | No change |
| Behaviour after programming | list | Deactivate alarm |
Version history
| Application | App no | Fingerprint | First seen | Size | File |
|---|---|---|---|---|---|
| KNX SA 16MDC SMI LoVo REG 1.0 latest | $FFE6 | E0C4 | 2026-11-25 | 349 KB | Download |
About this file
This is the official ETS product database for the WAREMA Renkhoff SE KNX SA 16MDC SMI LoVo REG (2022489), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.
More from WAREMA Renkhoff SE
- KNX MSE 6M230 1002632
- KNX SA 2M230 REG 2014568
- KNX SA 2M230.4 AP 2014569
- KNX SA 4M230 REG 2014570
- KNX SA 4M230.8 AP 2014571
- KNX SA 4MDC REG 2014572
- KNX SA 4MDC.8 AP 2014573
- KNX SA 6M230 REG 2014574
- KNX SA 6M230.12 AP 2014575
- KNX SA 8M230 REG 2014576
- KNX SA 8M230.16 AP 2014577
- KNX SA 2M100.4 AP 2019180