KNX Database
WAREMA Renkhoff SE 2014576 KNX SA 8M230 REG

KNX SA 8M230 REG 2014576

WAREMA Renkhoff SE · Order number 2014576 · Actuator › Venetian blind

Download .knxprod KNX SA 8M230 REG 1.0 · 325 KB

Product

ManufacturerWAREMA Renkhoff SE
Product nameKNX SA 8M230 REG
Order number2014576
HardwareHardware_warema_knx_sa_8m230_reg
MediumTwisted Pair
Bus current (mA)12
Rail mountedYes
Width (mm)106
RegistrationCertified · 2016-12-05
Languagesen-US, fr-FR, nl-NL, de-DE
Catalog entryM-006B_H-0008-0_HP-FFEF-10-1586_CI-2014576-1
Fingerprint1586
SHA-2562cc414d0f6a97ed9599105caed753a2393f4448cea5d3c41e468c0e1611798b4
First seen2026-11-25
Markets42 markets

Application program: KNX SA 8M230 REG 1.0

Application number$FFEF
Version1.0
Mask versionMV-07B0 (System B)
KNX Data SecureNo
Minimum ETS version4.0
Parameters2985
Group objects267
Group objects (267)
NoNameFunctionSizeDPTFlags
1Output 1Up/Down move command1 BitDPT.1CW
2Output 1Stop/Step move command1 BitDPT.1CW
2Output 1Stop command1 BitDPT.1CW
3Output 1Move to blind length manually1 ByteDPT.5CW
4Output 1Move to slat position manually1 ByteDPT.5CW
5Output 1Enable automatic objects1 BitDPT.1CW
6Output 1Move to blind length automatically1 ByteDPT.5CW
7Output 1Move to slat position automatically1 ByteDPT.5CW
8Output 1Move to automatic position 11 BitDPT.1CW
9Output 1Move to automatic position 21 BitDPT.1CW
10Output 1Save automatic position 11 BitDPT.1CW
11Output 1Save automatic position 21 BitDPT.1CW
12Output 1Automatic position toggle1 BitDPT.1CW
13Output 1Limitation of manual operation in automatic mode1 BitDPT.1CW
14Output 1Dwell time active1 BitDPT.1CRT
15Output 1Safety object C11 BitDPT.1CW
16Output 1Disable object1 BitDPT.1CW
17Output 1Scenes1 ByteDPT.18CW
18Output 1Disable scenes1 BitDPT.1CW
18Output 1:Disable scenes1 BitDPT.1CW
19Output 1Upper limit position reached1 BitDPT.1CRT
19Output 1Actual blind length1 ByteDPT.5CRT
20Output 1Actual blind length1 ByteDPT.5CRT
21Output 1Actual slat position1 ByteDPT.5CRT
22Output 2Up/Down move command1 BitDPT.1CW
23Output 2Stop/Step move command1 BitDPT.1CW
23Output 2Stop command1 BitDPT.1CW
24Output 2Move to blind length manually1 ByteDPT.5CW
25Output 2Move to slat position manually1 ByteDPT.5CW
26Output 2Enable automatic objects1 BitDPT.1CW
27Output 2Move to blind length automatically1 ByteDPT.5CW
28Output 2Move to slat position automatically1 ByteDPT.5CW
29Output 2Move to automatic position 11 BitDPT.1CW
30Output 2Move to automatic position 21 BitDPT.1CW
31Output 2Save automatic position 11 BitDPT.1CW
32Output 2Save automatic position 21 BitDPT.1CW
33Output 2Automatic position toggle1 BitDPT.1CW
34Output 2Limitation of manual operation in automatic mode1 BitDPT.1CW
35Output 2Dwell time active1 BitDPT.1CRT
36Output 2Safety object C21 BitDPT.1CW
37Output 2Disable object1 BitDPT.1CW
38Output 2Scenes1 ByteDPT.18CW
39Output 2Disable scenes1 BitDPT.1CW
39Output 2:Disable scenes1 BitDPT.1CW
40Output 2Upper limit position reached1 BitDPT.1CRT
40Output 2Actual blind length1 ByteDPT.5CRT
41Output 2Actual blind length1 ByteDPT.5CRT
42Output 2Actual slat position1 ByteDPT.5CRT
43Output 3Up/Down move command1 BitDPT.1CW
44Output 3Stop/Step move command1 BitDPT.1CW
44Output 3Stop command1 BitDPT.1CW
45Output 3Move to blind length manually1 ByteDPT.5CW
46Output 3Move to slat position manually1 ByteDPT.5CW
47Output 3Enable automatic objects1 BitDPT.1CW
48Output 3Move to blind length automatically1 ByteDPT.5CW
49Output 3Move to slat position automatically1 ByteDPT.5CW
50Output 3Move to automatic position 11 BitDPT.1CW
51Output 3Move to automatic position 21 BitDPT.1CW
52Output 3Save automatic position 11 BitDPT.1CW
53Output 3Save automatic position 21 BitDPT.1CW
54Output 3Automatic position toggle1 BitDPT.1CW
55Output 3Limitation of manual operation in automatic mode1 BitDPT.1CW
56Output 3Dwell time active1 BitDPT.1CRT
57Output 3Safety object C31 BitDPT.1CW
58Output 3Disable object1 BitDPT.1CW
59Output 3Scenes1 ByteDPT.18CW
60Output 3Disable scenes1 BitDPT.1CW
60Output 3:Disable scenes1 BitDPT.1CW
61Output 3Upper limit position reached1 BitDPT.1CRT
61Output 3Actual blind length1 ByteDPT.5CRT
62Output 3Actual blind length1 ByteDPT.5CRT
63Output 3Actual slat position1 ByteDPT.5CRT
64Output 4Up/Down move command1 BitDPT.1CW
65Output 4Stop/Step move command1 BitDPT.1CW
65Output 4Stop command1 BitDPT.1CW
66Output 4Move to blind length manually1 ByteDPT.5CW
67Output 4Move to slat position manually1 ByteDPT.5CW
68Output 4Enable automatic objects1 BitDPT.1CW
69Output 4Move to blind length automatically1 ByteDPT.5CW
70Output 4Move to slat position automatically1 ByteDPT.5CW
71Output 4Move to automatic position 11 BitDPT.1CW
72Output 4Move to automatic position 21 BitDPT.1CW
73Output 4Save automatic position 11 BitDPT.1CW
74Output 4Save automatic position 21 BitDPT.1CW
75Output 4Automatic position toggle1 BitDPT.1CW
76Output 4Limitation of manual operation in automatic mode1 BitDPT.1CW
77Output 4Dwell time active1 BitDPT.1CRT
78Output 4Safety object C41 BitDPT.1CW
79Output 4Disable object1 BitDPT.1CW
80Output 4Scenes1 ByteDPT.18CW
81Output 4Disable scenes1 BitDPT.1CW
81Output 4:Disable scenes1 BitDPT.1CW
82Output 4Upper limit position reached1 BitDPT.1CRT
82Output 4Actual blind length1 ByteDPT.5CRT
83Output 4Actual blind length1 ByteDPT.5CRT
84Output 4Actual slat position1 ByteDPT.5CRT
85Output 5Up/Down move command1 BitDPT.1CW
86Output 5Stop/Step move command1 BitDPT.1CW
86Output 5Stop command1 BitDPT.1CW
87Output 5Move to blind length manually1 ByteDPT.5CW
88Output 5Move to slat position manually1 ByteDPT.5CW
89Output 5Enable automatic objects1 BitDPT.1CW
90Output 5Move to blind length automatically1 ByteDPT.5CW
91Output 5Move to slat position automatically1 ByteDPT.5CW
92Output 5Move to automatic position 11 BitDPT.1CW
93Output 5Move to automatic position 21 BitDPT.1CW
94Output 5Save automatic position 11 BitDPT.1CW
95Output 5Save automatic position 21 BitDPT.1CW
96Output 5Automatic position toggle1 BitDPT.1CW
97Output 5Limitation of manual operation in automatic mode1 BitDPT.1CW
98Output 5Dwell time active1 BitDPT.1CRT
99Output 5Safety object C51 BitDPT.1CW
100Output 5Disable object1 BitDPT.1CW
101Output 5Scenes1 ByteDPT.18CW
102Output 5Disable scenes1 BitDPT.1CW
102Output 5:Disable scenes1 BitDPT.1CW
103Output 5Upper limit position reached1 BitDPT.1CRT
103Output 5Actual blind length1 ByteDPT.5CRT
104Output 5Actual blind length1 ByteDPT.5CRT
105Output 5Actual slat position1 ByteDPT.5CRT
106Output 6Up/Down move command1 BitDPT.1CW
107Output 6Stop/Step move command1 BitDPT.1CW
107Output 6Stop command1 BitDPT.1CW
108Output 6Move to blind length manually1 ByteDPT.5CW
109Output 6Move to slat position manually1 ByteDPT.5CW
110Output 6Enable automatic objects1 BitDPT.1CW
111Output 6Move to blind length automatically1 ByteDPT.5CW
112Output 6Move to slat position automatically1 ByteDPT.5CW
113Output 6Move to automatic position 11 BitDPT.1CW
114Output 6Move to automatic position 21 BitDPT.1CW
115Output 6Save automatic position 11 BitDPT.1CW
116Output 6Save automatic position 21 BitDPT.1CW
117Output 6Automatic position toggle1 BitDPT.1CW
118Output 6Limitation of manual operation in automatic mode1 BitDPT.1CW
119Output 6Dwell time active1 BitDPT.1CRT
120Output 6Safety object C61 BitDPT.1CW
121Output 6Disable object1 BitDPT.1CW
122Output 6Scenes1 ByteDPT.18CW
123Output 6Disable scenes1 BitDPT.1CW
123Output 6:Disable scenes1 BitDPT.1CW
124Output 6Upper limit position reached1 BitDPT.1CRT
124Output 6Actual blind length1 ByteDPT.5CRT
125Output 6Actual blind length1 ByteDPT.5CRT
126Output 6Actual slat position1 ByteDPT.5CRT
127Output 7Up/Down move command1 BitDPT.1CW
128Output 7Stop/Step move command1 BitDPT.1CW
128Output 7Stop command1 BitDPT.1CW
129Output 7Move to blind length manually1 ByteDPT.5CW
130Output 7Move to slat position manually1 ByteDPT.5CW
131Output 7Enable automatic objects1 BitDPT.1CW
132Output 7Move to blind length automatically1 ByteDPT.5CW
133Output 7Move to slat position automatically1 ByteDPT.5CW
134Output 7Move to automatic position 11 BitDPT.1CW
135Output 7Move to automatic position 21 BitDPT.1CW
136Output 7Save automatic position 11 BitDPT.1CW
137Output 7Save automatic position 21 BitDPT.1CW
138Output 7Automatic position toggle1 BitDPT.1CW
139Output 7Limitation of manual operation in automatic mode1 BitDPT.1CW
140Output 7Dwell time active1 BitDPT.1CRT
141Output 7Safety object C71 BitDPT.1CW
142Output 7Disable object1 BitDPT.1CW
143Output 7Scenes1 ByteDPT.18CW
144Output 7Disable scenes1 BitDPT.1CW
144Output 7:Disable scenes1 BitDPT.1CW
145Output 7Upper limit position reached1 BitDPT.1CRT
145Output 7Actual blind length1 ByteDPT.5CRT
146Output 7Actual blind length1 ByteDPT.5CRT
147Output 7Actual slat position1 ByteDPT.5CRT
148Output 8Up/Down move command1 BitDPT.1CW
149Output 8Stop/Step move command1 BitDPT.1CW
149Output 8Stop command1 BitDPT.1CW
150Output 8Move to blind length manually1 ByteDPT.5CW
151Output 8Move to slat position manually1 ByteDPT.5CW
152Output 8Enable automatic objects1 BitDPT.1CW
153Output 8Move to blind length automatically1 ByteDPT.5CW
154Output 8Move to slat position automatically1 ByteDPT.5CW
155Output 8Move to automatic position 11 BitDPT.1CW
156Output 8Move to automatic position 21 BitDPT.1CW
157Output 8Save automatic position 11 BitDPT.1CW
158Output 8Save automatic position 21 BitDPT.1CW
159Output 8Automatic position toggle1 BitDPT.1CW
160Output 8Limitation of manual operation in automatic mode1 BitDPT.1CW
161Output 8Dwell time active1 BitDPT.1CRT
162Output 8Safety object C81 BitDPT.1CW
163Output 8Disable object1 BitDPT.1CW
164Output 8Scenes1 ByteDPT.18CW
165Output 8Disable scenes1 BitDPT.1CW
165Output 8:Disable scenes1 BitDPT.1CW
166Output 8Upper limit position reached1 BitDPT.1CRT
166Output 8Actual blind length1 ByteDPT.5CRT
167Output 8Actual blind length1 ByteDPT.5CRT
168Output 8Actual slat position1 ByteDPT.5CRT
169Input 1Up/Down move command1 BitDPT.1CT
169Input 1On/Off/Toggle 1.11 BitDPT.1CWT
169Input 1Sensor 1.11 ByteDPT.5CT
169Input 1Scene 1.11 ByteDPT.18CT
170Input 1Stop/Step move command1 BitDPT.1CT
170Input 1On/Off/Toggle 1.21 BitDPT.1CWT
170Input 1Sensor 1.21 ByteDPT.5CT
170Input 1Scene 1.21 ByteDPT.18CT
171Input 1Enable1 BitDPT.1CW
174Input 2Up/Down move command1 BitDPT.1CT
174Input 2On/Off/Toggle 2.11 BitDPT.1CWT
174Input 2Sensor 2.11 ByteDPT.5CT
174Input 2Scene 2.11 ByteDPT.18CT
175Input 2Stop/Step move command1 BitDPT.1CT
175Input 2On/Off/Toggle 2.21 BitDPT.1CWT
175Input 2Sensor 2.21 ByteDPT.5CT
175Input 2Scene 2.21 ByteDPT.18CT
176Input 2Enable1 BitDPT.1CW
179Input 3Up/Down move command1 BitDPT.1CT
179Input 3On/Off/Toggle 3.11 BitDPT.1CWT
179Input 3Sensor 3.11 ByteDPT.5CT
179Input 3Scene 3.11 ByteDPT.18CT
180Input 3Stop/Step move command1 BitDPT.1CT
180Input 3On/Off/Toggle 3.21 BitDPT.1CWT
180Input 3Sensor 3.21 ByteDPT.5CT
180Input 3Scene 3.21 ByteDPT.18CT
181Input 3Enable1 BitDPT.1CW
184Input 4Up/Down move command1 BitDPT.1CT
184Input 4On/Off/Toggle 4.11 BitDPT.1CWT
184Input 4Sensor 4.11 ByteDPT.5CT
184Input 4Scene 4.11 ByteDPT.18CT
185Input 4Stop/Step move command1 BitDPT.1CT
185Input 4On/Off/Toggle 4.21 BitDPT.1CWT
185Input 4Sensor 4.21 ByteDPT.5CT
185Input 4Scene 4.21 ByteDPT.18CT
186Input 4Enable1 BitDPT.1CW
189Input 5Up/Down move command1 BitDPT.1CT
189Input 5On/Off/Toggle 5.11 BitDPT.1CWT
189Input 5Sensor 5.11 ByteDPT.5CT
189Input 5Scene 5.11 ByteDPT.18CT
190Input 5Stop/Step move command1 BitDPT.1CT
190Input 5On/Off/Toggle 5.21 BitDPT.1CWT
190Input 5Sensor 5.21 ByteDPT.5CT
190Input 5Scene 5.21 ByteDPT.18CT
191Input 5Enable1 BitDPT.1CW
194Input 6Up/Down move command1 BitDPT.1CT
194Input 6On/Off/Toggle 6.11 BitDPT.1CWT
194Input 6Sensor 6.11 ByteDPT.5CT
194Input 6Scene 6.11 ByteDPT.18CT
195Input 6Stop/Step move command1 BitDPT.1CT
195Input 6On/Off/Toggle 6.21 BitDPT.1CWT
195Input 6Sensor 6.21 ByteDPT.5CT
195Input 6Scene 6.21 ByteDPT.18CT
196Input 6Enable1 BitDPT.1CW
199Input 7Up/Down move command1 BitDPT.1CT
199Input 7On/Off/Toggle 7.11 BitDPT.1CWT
199Input 7Sensor 7.11 ByteDPT.5CT
199Input 7Scene 7.11 ByteDPT.18CT
200Input 7Stop/Step move command1 BitDPT.1CT
200Input 7On/Off/Toggle 7.21 BitDPT.1CWT
200Input 7Sensor 7.21 ByteDPT.5CT
200Input 7Scene 7.21 ByteDPT.18CT
201Input 7Enable1 BitDPT.1CW
204Input 8Up/Down move command1 BitDPT.1CT
204Input 8On/Off/Toggle 8.11 BitDPT.1CWT
204Input 8Sensor 8.11 ByteDPT.5CT
204Input 8Scene 8.11 ByteDPT.18CT
205Input 8Stop/Step move command1 BitDPT.1CT
205Input 8On/Off/Toggle 8.21 BitDPT.1CWT
205Input 8Sensor 8.21 ByteDPT.5CT
205Input 8Scene 8.21 ByteDPT.18CT
206Input 8Enable1 BitDPT.1CW
209All OutputsSafety object A1 BitDPT.1CW
210All OutputsSafety object B1 BitDPT.1CW
219All OutputsSafety object D1 BitDPT.1CW
Parameters (159)
ParameterTypeDefault
Send and switch delay timelistStartup Delay after Boot
Maximum telegram ratelistRestriction off
Bluetooth visiblelistOFF
BluetoothlistOn
Bluetooth Login KeyunsignedInt 0…99993706
PID_HARDWARE_TYPE_PARAMETERlist
Kanal Ausgang 1 sichtbarlistON
Kanal Ausgang 2 sichtbarlistON
Kanal Ausgang 3 sichtbarlistON
Kanal Ausgang 4 sichtbarlistON
Kanal Ausgang 5 sichtbarlistON
Kanal Ausgang 6 sichtbarlistON
Kanal Ausgang 7 sichtbarlistON
Kanal Ausgang 8 sichtbarlistON
Kanal Eingang 1 sichtbarlistOFF
Kanal Eingang 2 sichtbarlistOFF
Kanal Eingang 3 sichtbarlistOFF
Kanal Eingang 4 sichtbarlistOFF
Kanal Eingang 5 sichtbarlistOFF
Kanal Eingang 6 sichtbarlistOFF
Kanal Eingang 7 sichtbarlistOFF
Kanal Eingang 8 sichtbarlistOFF
Identical settings for all outputslistOn
Operating mode of output 1listNot used
Operating mode of output 2listNot used
Operating mode of output 3listNot used
Operating mode of output 4listNot used
Operating mode of output 5listNot used
Operating mode of output 6listNot used
Operating mode of output 7listNot used
Operating mode of output 8listNot used
Operating mode of outputs 1 - 8listNot used
Update of the status objectslistAfter movement
Time-offset output actuationlistDisabled
Overwrite scene memory when programminglistOn
Object "upper limit position reached"list1 = upper limit
Run time up [seconds]unsignedInt 0…300300
Run time down [seconds]unsignedInt 0…300300
Tilting time [milliseconds]unsignedInt 0…250001600
Slat tilting by step command [%]unsignedInt 0…10015
Slat position after downward movement [%]unsignedInt 0…10070
Reverse motor rotation directionlistNo
Minimum pause after stop [milliseconds]unsignedInt 500…5000500
Additional time at upper limit position [seconds]unsignedInt 0…253
Additional time at lower limit position [seconds]unsignedInt 0…253
Correction time 1 [milliseconds]unsignedInt 0…50000
Correction time 2 [milliseconds]unsignedInt 0…50000
Motor start correction time [milliseconds]unsignedInt 0…50000
Speed 1 [rpm]unsignedInt 0…2550
Speed 2 [rpm]unsignedInt 0…2550
Duration speed 1 [milliseconds]unsignedInt 0…250000
Monitoring time for disable objectlistCyclical monitoring off
Behaviour when alarm active through safety object AlistUp
Blind length [%]unsignedInt 0…1000
Slat position [%]unsignedInt 0…1000
Behaviour when alarm ends through safety object AlistRestore automatic/manual/scene
Behaviour when alarm active through safety object BlistUp
Behaviour when alarm ends through safety object BlistRestore automatic/manual/scene
Behaviour when alarm active through safety object C1listUp
Behaviour when alarm ends through safety object C1listRestore automatic/manual/scene
Behaviour when alarm active through safety object DlistUp
Behaviour when alarm ends through safety object DlistRestore automatic/manual/scene
Behaviour after a bus voltage failurelistNo reaction
Behaviour after bus or mains voltage returnlistNo reaction
Scene 1textScene 1
ScenelistDo not use
Scene numberunsignedInt 1…641
Storage via telegram permittedlistYes
Scene 2textScene 2
Scene numberunsignedInt 1…642
Scene 3textScene 3
Scene numberunsignedInt 1…643
Scene 4textScene 4
Scene numberunsignedInt 1…644
Scene 5textScene 5
Scene numberunsignedInt 1…645
Scene 6textScene 6
Scene numberunsignedInt 1…646
Scene 7textScene 7
Scene numberunsignedInt 1…647
Scene 8textScene 8
Scene numberunsignedInt 1…648
Use automatic objectslistNo
Use automatic positions 1 and 2listNo
Automatic delay after manual operation [hh:mm]time0
Behaviour after expiry of automatic delaylistPerform last automatic object
Object "Dwell time active"list1 = active
Limitation of manual operation if object "Limitation of manual operation in automatic mode" = 1listDisable manual operation and scenes
Min. blind lengthlistFrom automatic blind length object
Min. blind length [%]unsignedInt 0…1000
Max. blind lengthlistNo restriction
Max. blind length [%]unsignedInt 0…100100
Min. slat anglelistFrom automatic slat angle object
Min. slat angle [%]unsignedInt 0…1000
Max. slat anglelistNo restriction
Max. slat angle [%]unsignedInt 0…100100
Automatic position 1 blind length [%]unsignedInt 0…100100
Automatic position 1 slat position [%]unsignedInt 0…10070
Automatic position 2 blind length [%]unsignedInt 0…10050
Automatic position 2 slat position [%]unsignedInt 0…10070
Position toggle delay time [hh:mm]time192
Save positions 1+2 via telegramlistOff
Overwrite positions saved on-site when programminglistOff
Correction time 2 [milliseconds]unsignedInt 0…50000
Behaviour when alarm ends through safety object AlistStop
Behaviour when alarm ends through safety object BlistStop
Behaviour when alarm ends through safety object C1listStop
Behaviour when alarm ends through safety object DlistStop
Behaviour when alarm active through safety object C2listUp
Behaviour when alarm ends through safety object C2listRestore automatic/manual/scene
Behaviour when alarm ends through safety object C2listStop
Behaviour when alarm active through safety object C3listUp
Behaviour when alarm ends through safety object C3listRestore automatic/manual/scene
Behaviour when alarm ends through safety object C3listStop
Behaviour when alarm active through safety object C4listUp
Behaviour when alarm ends through safety object C4listRestore automatic/manual/scene
Behaviour when alarm ends through safety object C4listStop
Behaviour when alarm active through safety object C5listUp
Behaviour when alarm ends through safety object C5listRestore automatic/manual/scene
Behaviour when alarm ends through safety object C5listStop
Behaviour when alarm active through safety object C6listUp
Behaviour when alarm ends through safety object C6listRestore automatic/manual/scene
Behaviour when alarm ends through safety object C6listStop
Behaviour when alarm active through safety object C7listUp
Behaviour when alarm ends through safety object C7listRestore automatic/manual/scene
Behaviour when alarm ends through safety object C7listStop
Behaviour when alarm active through safety object C8listUp
Behaviour when alarm ends through safety object C8listRestore automatic/manual/scene
Behaviour when alarm ends through safety object C8listStop
Behaviour when alarm active through safety object C1 - C8listUp
Behaviour when alarm ends through safety object C1 - C8listRestore automatic/manual/scene
Behaviour when alarm ends through safety object C1 - C8listStop
Kanal für Inputs sichtbarlistOFF
Operating mode of inputs 1.1/1.2listNot used
Operating mode of inputs 2.1/2.2listNot used
Operating mode of inputs 3.1/3.2listNot used
Operating mode of inputs 4.1/4.2listNot used
Operating mode of inputs 5.1/5.2listNot used
Operating mode of inputs 6.1/6.2listNot used
Operating mode of inputs 7.1/7.2listNot used
Operating mode of inputs 8.1/8.2listNot used
Delay after a bus voltage return [seconds]unsignedInt 3…2553
Input signal is interpreted as long afterlist1.0 seconds
Telegram after a short press of the buttonlistStop/Step move command
Telegram after a long press of the buttonlistUp/Down move command
Time for cyclic sending [hh:mm:ss]time0
Telegram after rising edgelistToggle
Telegram after falling edgelistNo function
Telegram after the bus or mains voltage returnslistDo not send value
Send BehaviourlistSend value at both edges
Telegram after rising edgeunsignedInt 0…255128
Telegram after falling edgeunsignedInt 0…255128
Scenes numberunsignedInt 1…641
Telegram after a short press of the buttonlistExecute scene
Telegram after a long press of the buttonlistNo function
Cyclic monitoringlistCyclical monitoring off
Behaviour when the bus or mains voltage returnslistDeactivate alarm
Behaviour in case of bus voltage failurelistActivate alarm
Behaviour after programminglistDeactivate alarm

Version history

ApplicationApp noFingerprintFirst seenSizeFile
KNX SA 8M230 REG 1.0 latest$FFEF15862026-11-25325 KBDownload

About this file

This is the official ETS product database for the WAREMA Renkhoff SE KNX SA 8M230 REG (2014576), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.

More from WAREMA Renkhoff SE

All WAREMA Renkhoff SE products