02952 KNX Touch Thermostat 02952
VIMAR · Order number 02952 · Hotel › Thermostat
02952 KNX Touch Thermostat
Download .knxprod KNX Touch Thermostat 3.1 · 123 KB
Product
| Manufacturer | VIMAR |
|---|---|
| Product name | 02952 KNX Touch Thermostat |
| Order number | 02952 |
| Hardware | 02952 KNX Touch Thermostat |
| Medium | Twisted Pair |
| Bus current (mA) | 10 |
| Rail mounted | No |
| Registration | Certified · 2020-07-31 |
| Languages | de-DE, en-US, it-IT |
| Catalog entry | M-002C_H-295201-2_HP-0B88-31-58A8_CI-02952-0 |
| Fingerprint | 58A8 |
| SHA-256 | 11fc9b3cbce6540aa8e2f61a5c936bb97303246d1397f28554227bb6a3517d97 |
| First seen | 2026-11-25 |
| Markets | 69 markets |
Application program: KNX Touch Thermostat 3.1
| Application number | $0B88 |
|---|---|
| Version | 3.1 |
| Mask version | MV-0705 (7.5) |
| KNX Data Secure | No |
| Minimum ETS version | 4.0 |
| Parameters | 521 |
| Group objects | 130 |
Group objects (130)
| No | Name | Function | Size | DPT | Flags |
|---|---|---|---|---|---|
| 0 | Internal Sensor | Temperature | 2 Bytes | 9.1 temperature (°C) | CRT |
| 1 | External Sensor | Temperature | 2 Bytes | 9.1 temperature (°C) | CRT |
| 2 | Outside temperature 1 | Temperature | 2 Bytes | 9.1 temperature (°C) | CWU |
| 3 | Outside temperature 2 | Temperature | 2 Bytes | 9.1 temperature (°C) | CWU |
| 4 | Outside temperature 3 | Temperature | 2 Bytes | 9.1 temperature (°C) | CWU |
| 5 | Outside temperature 4 | Temperature | 2 Bytes | 9.1 temperature (°C) | CWU |
| 6 | Outside temperature 5 | Temperature | 2 Bytes | 9.1 temperature (°C) | CWU |
| 7 | Outside temperature 6 | Temperature | 2 Bytes | 9.1 temperature (°C) | CWU |
| 8 | Outside temperature 7 | Temperature | 2 Bytes | 9.1 temperature (°C) | CWU |
| 9 | Outside temperature 8 | Temperature | 2 Bytes | 9.1 temperature (°C) | CWU |
| 10 | Actual Temperature | A: Temperature | 2 Bytes | 9.1 temperature (°C) | CRT |
| 11 | Actual Temperature | B: Temperature | 2 Bytes | 9.1 temperature (°C) | CRT |
| 12 | Comfort | A: Mode | 1 Bit | 1.17 trigger | CWU |
| 13 | Economy | A: Mode | 1 Bit | 1.17 trigger | CWU |
| 14 | Protect | A: Mode | 1 Bit | 1.17 trigger | CWU |
| 15 | Off | A: Mode | 1 Bit | 1.17 trigger | CRWU |
| 16 | Thermostat mode | A: Mode | 1 Byte | 20.102 HVAC mode | CWU |
| 17 | Thermostat mode | A: Mode State | 1 Byte | 20.102 HVAC mode | CRT |
| 18 | State | A: Summer / Winter | 1 Bit | 1.2 boolean | CRT |
| 19 | Enable | A: Summer / Winter | 1 Bit | 1.2 boolean | CWU |
| 20 | Thermostat off | A: Thermostat | 1 Bit | 1.1 switch | CWU |
| 21 | Dewpoint | A: Thermostat | 1 Bit | 1.1 switch | CWU |
| 22 | dummy | 1 Bit | 1.1 switch | CWU | |
| 23 | Actual Setpoint | A: Setpoint | 2 Bytes | 9.1 temperature (°C) | CRT |
| 24 | Setpoint Shift | A: Setpoint | 2 Bytes | 9.1 temperature (°C) | CRWT |
| 25 | Comfort Winter | A: Setpoint | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 26 | Standby Winter | A: Setpoint | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 27 | Economy Winter | A: Setpoint | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 28 | Protect Winter | A: Setpoint | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 29 | Comfort Summer | A: Setpoint | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 30 | Standby Summer | A: Setpoint | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 31 | Economy Summer | A: Setpoint | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 32 | Protect Summer | A: Setpoint | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 33 | Control Value | A: Control Value | 1 Byte | 5.1 percentage (0..100%) | CRWT |
| 34 | Cooling / Heating Valve | A: Valve | 1 Bit | 1.1 switch | CRT |
| 34 | Cooling Valve | A: Valve | 1 Bit | 1.1 switch | CRT |
| 34 | Cooling / Heating Valve | A: Valve | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 34 | Cooling Valve | A: Valve | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 35 | Heating Valve | A: Valve | 1 Bit | 1.1 switch | CRT |
| 35 | Heating Valve | A: Valve | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 36 | Cooling Valve | A: 2-nd stage cooling | 1 Bit | 1.1 switch | CRT |
| 36 | Cooling Valve | A: 2-nd stage cooling | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 37 | Heating Valve | A: 2-nd stage heating | 1 Bit | 1.1 switch | CRT |
| 37 | Heating Valve | A: 2-nd level heating | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 38 | Proportional (0 - 100%) | A: Fan Inputs | 1 Byte | 5.1 percentage (0..100%) | CWU |
| 39 | Off | A: Fan Inputs | 1 Bit | 1.1 switch | CWU |
| 40 | Speed V1 | A: Fan Inputs | 1 Bit | 1.1 switch | CWU |
| 41 | Speed V2 | A: Fan Inputs | 1 Bit | 1.1 switch | CWU |
| 42 | Speed V3 | A: Fan Inputs | 1 Bit | 1.1 switch | CWU |
| 43 | Automatic | A: Fan Inputs | 1 Bit | 1.1 switch | CWU |
| 44 | Proportional (0 - 100%) | A: Fan Outputs | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 45 | Off | A: Fan Outputs | 1 Bit | 1.1 switch | CRT |
| 46 | Speed V1 | A: Fan Outputs | 1 Bit | 1.1 switch | CRT |
| 47 | Speed V2 | A: Fan Outputs | 1 Bit | 1.1 switch | CRT |
| 48 | Speed V3 | A: Fan Outputs | 1 Bit | 1.1 switch | CRWT |
| 49 | Speed V1 | A: Fan Disable | 1 Bit | 1.1 switch | CRWTU |
| 50 | Speed V2 | A: Fan Disable | 1 Bit | 1.1 switch | CRWTU |
| 51 | Speed V3 | A: Fan Disable | 1 Bit | 1.1 switch | CRWTU |
| 52 | Window switch | A: Window | 1 Bit | 1.1 switch | CWU |
| 53 | Scene | A: Scene | 1 Byte | 18.1 scene control | CWU |
| 54 | Temperature: Automatic / Manual | A: Manual operation | 1 Bit | 1.1 switch | CRT |
| 55 | Fancoil:Automatic / Manual | A: Manual operation | 1 Bit | 1.1 switch | CRT |
| 56 | Temperature: disable local operation | A: Manual operation | 1 Bit | 1.1 switch | CWU |
| 57 | Fancoil: disable local operation | A: Manual operation | 1 Bit | 1.1 switch | CWU |
| 58 | Floor Temperature | A: Alarm | 1 Bit | 1.1 switch | CRT |
| 59 | Comfort | B: Mode | 1 Bit | 1.17 trigger | CWU |
| 60 | Economy | B: Mode | 1 Bit | 1.17 trigger | CWU |
| 61 | Protect | B: Mode | 1 Bit | 1.17 trigger | CWU |
| 62 | Off | B: Mode | 1 Bit | 1.17 trigger | CRWU |
| 63 | Thermostat mode | B: Mode | 1 Byte | 20.102 HVAC mode | CWU |
| 64 | Thermostat mode | B: Mode State | 1 Byte | 20.102 HVAC mode | CRT |
| 65 | State | B: Summer / Winter | 1 Bit | 1.2 boolean | CRT |
| 66 | Enable | B: Summer / Winter | 1 Bit | 1.2 boolean | CWU |
| 67 | Thermostat off | B: Thermostat | 1 Bit | 1.1 switch | CWU |
| 68 | Dewpoint | B: Thermostat | 1 Bit | 1.1 switch | CWU |
| 69 | dummy | 1 Bit | 1.1 switch | CWU | |
| 70 | Actual Setpoint | B: Setpoint | 2 Bytes | 9.1 temperature (°C) | CRT |
| 71 | Setpoint Shift | B: Setpoint | 2 Bytes | 9.1 temperature (°C) | CRWT |
| 72 | Comfort Winter | B: Setpoint | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 73 | Standby Winter | B: Setpoint | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 74 | Economy Winter | B: Setpoint | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 75 | Protect Winter | B: Setpoint | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 76 | Comfort Summer | B: Setpoint | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 77 | Standby Summer | B: Setpoint | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 78 | Economy Summer | B: Setpoint | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 79 | Protect Summer | B: Setpoint | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 80 | Control Value | B: Control Value | 1 Byte | 5.1 percentage (0..100%) | CRWT |
| 81 | Cooling / Heating Valve | B: Valve | 1 Bit | 1.1 switch | CRT |
| 81 | Cooling Valve | B: Valve | 1 Bit | 1.1 switch | CRT |
| 81 | Cooling / Heating Valve | B: Valve | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 81 | Cooling Valve | B: Valve | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 82 | Heating Valve | B: Valve | 1 Bit | 1.1 switch | CRT |
| 82 | Heating Valve | B: Valve | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 83 | Cooling Valve | B: 2-nd stage cooling | 1 Bit | 1.1 switch | CRT |
| 83 | Cooling Valve | B: 2-nd stage cooling | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 84 | Heating Valve | B: 2-nd stage heating | 1 Bit | 1.1 switch | CRT |
| 84 | Heating Valve | B: 2-nd level heating | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 85 | Proportional (0 - 100%) | B: Fan Inputs | 1 Byte | 5.1 percentage (0..100%) | CWU |
| 86 | Off | B: Fan Inputs | 1 Bit | 1.1 switch | CWU |
| 87 | Speed V1 | B: Fan Inputs | 1 Bit | 1.1 switch | CWU |
| 88 | Speed V2 | B: Fan Inputs | 1 Bit | 1.1 switch | CWU |
| 89 | Speed V3 | B: Fan Inputs | 1 Bit | 1.1 switch | CWU |
| 90 | Automatic | B: Fan Inputs | 1 Bit | 1.1 switch | CWU |
| 91 | Proportional (0 - 100%) | B: Fan Outputs | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 92 | Off | B: Fan Outputs | 1 Bit | 1.1 switch | CRT |
| 93 | Speed V1 | B: Fan Outputs | 1 Bit | 1.1 switch | CRT |
| 94 | Speed V2 | B: Fan Outputs | 1 Bit | 1.1 switch | CRT |
| 95 | Speed V3 | B: Fan Outputs | 1 Bit | 1.1 switch | CRT |
| 96 | Speed V1 | B: Fan Disable | 1 Bit | 1.1 switch | CRWTU |
| 97 | Speed V2 | B: Fan Disable | 1 Bit | 1.1 switch | CRWTU |
| 98 | Speed V3 | B: Fan Disable | 1 Bit | 1.1 switch | CRWTU |
| 99 | Window switch | B: Window | 1 Bit | 1.1 switch | CWU |
| 100 | Scene | B: Scene | 1 Byte | 18.1 scene control | CWU |
| 101 | Temperature: Automatic / Manual | B: Manual operation | 1 Bit | 1.1 switch | CRT |
| 102 | Fancoil:Automatic / Manual | B: Manual operation | 1 Bit | 1.1 switch | CRT |
| 103 | Temperature: disable local operation | B: Manual operation | 1 Bit | 1.1 switch | CWU |
| 104 | Fancoil: disable local operation | B: Manual operation | 1 Bit | 1.1 switch | CWU |
| 105 | Floor Temperature | B: Alarm | 1 Bit | 1.1 switch | CRT |
| 106 | Initialization | Alarm | 1 Bit | 1.1 switch | CRT |
| 107 | Configuration error | Alarm | 1 Bit | 1.1 switch | CRT |
| 108 | Local configuration Change | Alarm | 1 Bit | 1.1 switch | CRT |
| 109 | General | Alarm | 1 Bit | 1.1 switch | CWT |
| 110 | Input | Input | 1 Bit | 1.1 switch | CRT |
| 111 | Status Input | Input | 1 Bit | 1.1 switch | CWU |
| 112 | On / Off | Relay | 1 Bit | 1.1 switch | CWU |
| 113 | State | Relay | 1 Bit | 1.1 switch | CRT |
| 114 | Value | Humidity | 2 Bytes | 9.7 humidity (%) | CWU |
| 114 | Value | Percentage | 1 Byte | 5.1 percentage (0..100%) | CWU |
| 115 | Setpoint shift up | A: Setpoint | 1 Bit | 1.1 switch | CWU |
| 116 | Setpoint shift down | A: Setpoint | 1 Bit | 1.1 switch | CWU |
Parameters (269)
| Parameter | Type | Default |
|---|---|---|
| >> Test | list | disable |
| Debug on | unsignedInt 0…0 | 0 |
| Debug off | unsignedInt 0…0 | 0 |
| Version | text | 10 |
| Version | text | 21 |
| 9/29/2016 | text | 9/29/2016 |
| Displayed value | list | show actual temperature |
| Keys activation | list | enable |
| Temperature Unit | list | Celsius |
| ETS download flag | unsignedInt 0…255 | 255 |
| first start flag | unsignedInt 0…255 | 0 |
| menu disabled | list | disable |
| menu enabled | list | disable |
| extended menu disabled | list | disable |
| extended menu enabled | list | disable |
| Enable Menu | list | enable |
| extended menu on | unsignedInt 0…0 | 0 |
| extended menu off | unsignedInt 0…0 | 0 |
| Enable Extended Menu | list | disable |
| Percent Display | list | humidity |
| Backlight | list | on button |
| Background Colour | list | Predefined colours |
| Colour | list | White (R 255, G 255, B 255) |
| Colour red LED | unsignedInt 0…255 | 255 |
| Colour green LED | unsignedInt 0…255 | 0 |
| Colour blue LED | unsignedInt 0…255 | 0 |
| Input Function | list | Window Switch |
| Input Function Window | unsignedInt 0…0 | 0 |
| Input Function General | unsignedInt 0…0 | 0 |
| Function | list | Status send |
| A: Window Switch Mode | list | Normally Opened |
| B: Window Switch Mode | list | Normally Opened |
| Function | list | Switch rising edge |
| Value Falliing Edge | list | off |
| Value Rising Edge | list | on |
| Cyclic sending | list | disable |
| Send Cycle Time | list | 30 sec |
| Temperature Offset | list | 0,0 °C |
| >> Test: value in | list | disable |
| Enable user interface | list | disable |
| Send Cycle Time | list | off |
| Send Difference | list | off |
| Enable | list | enable |
| VI_enableOn | unsignedInt 0…0 | 0 |
| VI_enableOff | unsignedInt 0…0 | 0 |
| Enable user interface | list | enable |
| Guest Permit Regulation | list | 3,0 °C |
| Weight of internal temperature sensor | unsignedInt 0…100 | 100 |
| Weight of external temperature sensor | unsignedInt 0…100 | 0 |
| Weight of outside temperature 1 | unsignedInt 0…100 | 0 |
| Weight of outside temperature 2 | unsignedInt 0…100 | 0 |
| Weight of outside temperature 3 | unsignedInt 0…100 | 0 |
| Weight of outside temperature 4 | unsignedInt 0…100 | 0 |
| Weight of outside temperature 5 | unsignedInt 0…100 | 0 |
| Weight of outside temperature 6 | unsignedInt 0…100 | 0 |
| Weight of outside temperature 7 | unsignedInt 0…100 | 0 |
| Weight of outside temperature 8 | unsignedInt 0…100 | 0 |
| Mode after bus return | list | last selected mode |
| Mode when window is open | list | Protect |
| Comfort propagation delay | list | off |
| action for comfort off | list | Standby |
| action for comfort on | list | Comfort |
| action for standby off | list | none |
| action for standby on | list | Standby |
| action for economy off | list | none |
| action for economy on | list | Economy |
| action for protection off | list | none |
| action for protection on | list | Protect |
| action for protection on | list | Off |
| Time Between Heating and Cooling | list | 30 min |
| Enable output object | list | enable |
| Enable flags 0 (heat/cool) | unsignedInt 0…255 | 185 |
| Enable 0 Supervision time | list | off |
| Enable 0 Error Value | unsignedInt 0…255 | 1 |
| Enable 0 Init Value | unsignedInt 0…255 | 1 |
| Enable flags 1 (off) | unsignedInt 0…255 | 187 |
| Enable 1 Supervision time | list | off |
| Enable 1 Error Value | unsignedInt 0…255 | 0 |
| Enable 1 Init Value | unsignedInt 0…255 | 0 |
| Enable flags 2 (dewpoint) | unsignedInt 0…255 | 176 |
| Supervision Time of Dew Point | list | off |
| Enable 1 Error Value | unsignedInt 0…255 | 1 |
| Enable flags 3 (window) | unsignedInt 0…255 | 0 |
| Supervision time Window | list | off |
| SP_basicSetPointReference0 | unsignedInt 0…255 | 0 |
| SP_basicSp_settings0 | unsignedInt 0…255 | 2 |
| SP_hysteresis_settings0 | unsignedInt 0…255 | 2 |
| SP_relSetpoint_settings0 | unsignedInt 0…255 | 0 |
| SP_comf_settings0 | unsignedInt 0…255 | 53 |
| SP_standby_settings0 | unsignedInt 0…255 | 53 |
| SP_eco_settings0 | unsignedInt 0…255 | 53 |
| SP_protect_settings0 | unsignedInt 0…255 | 21 |
| Send Cycle Timer | list | off |
| Reset Setpoint Shift in Economy Mode | list | Yes |
| SP_basicSetpoint | unsignedInt 0…255 | 5 |
| SP_hysteresis | unsignedInt 0…255 | 5 |
| Setpoint Comfort Winter | list | 20 °C |
| Setpoint Standby Winter | list | 18 °C |
| Setpoint Economy Winter | list | 15 °C |
| Antifreeze | list | Regulation On |
| Off in economy cooling | list | Regulation On |
| Off in standby cooling | list | Regulation On |
| Off in comfort cooling | list | Regulation On |
| Setpoint Antifreeze | list | 5 °C |
| Setpoint Comfort Summer | list | 25 °C |
| Setpoint Standby Summer | list | 28 °C |
| Setpoint Economy Summer | list | 30 °C |
| Too hot | list | Regulation Off |
| Setpoint Too Hot | list | 35 °C |
| WI_windowInvertOff | unsignedInt 0…0 | 0 |
| WI_windowInvertNo | unsignedInt 0…0 | 0 |
| WI_windowInvertYes | unsignedInt 0…0 | 0 |
| Delay for window switches | list | 30 sec |
| WI_settings0 | unsignedInt 0…255 | 0 |
| WI_settings1 | unsignedInt 0…255 | 5 |
| Temperature Regulation | list | Regulation On/Off |
| Regulation_Type_onOff | unsignedInt 0…0 | 0 |
| Regulation_Type_p | unsignedInt 0…0 | 0 |
| Regulation_Type_i | unsignedInt 0…0 | 0 |
| Regulation_Type_pi | unsignedInt 0…0 | 0 |
| Proportional Value Cooling | list | 3,0 °C |
| Integral Value Cooling | list | 5 min |
| Proportional Value Heating | list | 3,0 °C |
| Integral Value Heating | list | 5 min |
| regulation type | unsignedInt 0…255 | 0 |
| Differential coefficient | list | 0,2 °C |
| minimum time for off | unsignedInt 0…32767 | 2000 |
| minimum time for on | unsignedInt 0…32767 | 2000 |
| cycle time of regulation | unsignedInt 0…32767 | 1 |
| Type of control value object | list | DPT 6 |
| >> Test: direction of control value | list | out |
| >> Test: repetition time | list | off |
| supervision timer | list | off |
| object error value | unsignedInt 0…255 | 0 |
| object init value | unsignedInt 0…255 | 0 |
| Plant Topology | list | 2 Tubes Circuit On/Off |
| plant_2_on_off | unsignedInt 0…0 | 0 |
| VA_valve0PercLevel | unsignedInt 0…100 | 0 |
| VA_valve100PercLevel | unsignedInt 0…100 | 100 |
| Send Cycle Time Cool | list | off |
| Send Cycle Time Heat | list | off |
| VA_noOfValves | unsignedInt 1…2 | 1 |
| VA_valveTypeCool | list | EIS 1 |
| VA_valveTypeHeat | list | EIS 1 |
| VA_EIS1sendParamCool | unsignedInt 0…255 | 15 |
| VA_EIS1sendParamHeat | unsignedInt 0…255 | 15 |
| VA_sendDifferenceCool | unsignedInt 0…100 | 3 |
| VA_sendDifferenceHeat | unsignedInt 0…100 | 3 |
| Boost: NoOfObjects | list | 2 |
| Cooling 2° stage | list | disabled |
| Threshold Cooling | list | 5,0 °C |
| Heating 2° stage | list | disabled |
| Threshold Heating | list | 5,0 °C |
| Type | list | Three speed fan coil |
| FA_fanSpeedBasis | list | off |
| Type | unsignedInt 0…0 | 0 |
| FA_fanSwitchMode | list | fanSwitch |
| minimum switch on temperture | unsignedInt 0…255 | 0 |
| Maximum Fan Speed | unsignedInt 0…3 | 3 |
| Temperature for 100% | list | 5 °C |
| Maximum Fan Speed | unsignedInt 0…255 | 100 |
| Threshold value for fan speed 0 | list | 0,2 °C |
| Minimum Fan Speed | list | 10% |
| Threshold value for fan speed 1 | list | 0,2 °C |
| Time in manual fan mode (min) | unsignedInt 0…255 | 0 |
| Threshold value for fan speed 2 | list | 1,0 °C |
| FA_objOut100Diff | unsignedInt 0…100 | 3 |
| Threshold value for fan speed 3 | list | 2,0 °C |
| Hysterese of fan speed | list | 0,1 °C |
| absolute minimum time in one fan spped | unsignedInt 0…255 | 2 |
| Time for switching between speeds (min) | unsignedInt 0…255 | 2 |
| rollover in manual mode | unsignedInt 0…255 | 7 |
| FA_objInValues0 | unsignedInt 0…255 | 0 |
| FA_objInValues1 | unsignedInt 0…255 | 86 |
| FA_objInValues2 | unsignedInt 0…255 | 172 |
| FA_objInValues3 | unsignedInt 0…255 | 255 |
| FA_objOutValues0 | unsignedInt 0…255 | 0 |
| FA_objOutValues1 | unsignedInt 0…255 | 86 |
| FA_objOutValues2 | unsignedInt 0…255 | 172 |
| FA_objOutValues3 | unsignedInt 0…255 | 255 |
| FA_EIS1OutOffTime | unsignedInt 0…65535 | 1000 |
| Objects | list | 1 Bit object |
| Scene learning | list | enable |
| Scene 1 | list | disabled |
| Scene 2 | list | disabled |
| Scene 3 | list | disabled |
| Scene 4 | list | disabled |
| Scene 5 | list | disabled |
| Scene 6 | list | disabled |
| Scene 7 | list | disabled |
| Scene 8 | list | disabled |
| Scene 9 | list | disabled |
| Scene 10 | list | disabled |
| Scene 11 | list | disabled |
| Scene 12 | list | disabled |
| Scene 13 | list | disabled |
| Scene 14 | list | disabled |
| Scene 15 | list | disabled |
| Scene 16 | list | disabled |
| Scene 17 | list | disabled |
| Scene 18 | list | disabled |
| Scene 19 | list | disabled |
| Scene 20 | list | disabled |
| Scene 21 | list | disabled |
| Scene 22 | list | disabled |
| Scene 23 | list | disabled |
| Scene 24 | list | disabled |
| Scene 25 | list | disabled |
| Scene 26 | list | disabled |
| Scene 27 | list | disabled |
| Scene 28 | list | disabled |
| Scene 29 | list | disabled |
| Scene 30 | list | disabled |
| Scene 31 | list | disabled |
| Scene 32 | list | disabled |
| Scene 33 | list | disabled |
| Scene 34 | list | disabled |
| Scene 35 | list | disabled |
| Scene 36 | list | disabled |
| Scene 37 | list | disabled |
| Scene 38 | list | disabled |
| Scene 39 | list | disabled |
| Scene 40 | list | disabled |
| Scene 41 | list | disabled |
| Scene 42 | list | disabled |
| Scene 43 | list | disabled |
| Scene 44 | list | disabled |
| Scene 45 | list | disabled |
| Scene 46 | list | disabled |
| Scene 47 | list | disabled |
| Scene 48 | list | disabled |
| Scene 49 | list | disabled |
| Scene 50 | list | disabled |
| Scene 51 | list | disabled |
| Scene 52 | list | disabled |
| Scene 53 | list | disabled |
| Scene 54 | list | disabled |
| Scene 55 | list | disabled |
| Scene 56 | list | disabled |
| Scene 57 | list | disabled |
| Scene 58 | list | disabled |
| Scene 59 | list | disabled |
| Scene 60 | list | disabled |
| Scene 61 | list | disabled |
| Scene 62 | list | disabled |
| Scene 63 | list | disabled |
| Scene 64 | list | disabled |
| Temperature Channel | list | disabled |
| Temperature Limit | unsignedInt 10…70 | 35 |
| Weight of internal temperature sensor | unsignedInt 0…100 | 0 |
| Weight of external temperature sensor | unsignedInt 0…100 | 100 |
| Relay | list | General Purpose |
| relayNormal | unsignedInt 0…0 | 0 |
| relayFan | unsignedInt 0…0 | 0 |
| Mode | list | Normal |
| relayModeNormal | unsignedInt 0…0 | 0 |
| relayModeStaircase | unsignedInt 0…0 | 0 |
| VI_relayForFan | unsignedInt 0…255 | 0 |
| SO_mode | unsignedInt 0…255 | 0 |
| Switch On Delay | list | off |
| Switch Off Delay | list | off |
| Duration | list | off |
| Relay | list | Normally Opened |
| Fans independent of the valve | list | No |
| Automatic fan disabling | list | No |
| Selection Mode Visible | list | Yes |
| Setpoint shift step | list | 1 °C |
| Heating icon visible | list | Yes |
| Air-conditioning icon visible | list | Yes |
Version history
| Application | App no | Fingerprint | First seen | Size | File |
|---|---|---|---|---|---|
| KNX Touch Thermostat 3.1 latest | $0B88 | 58A8 | 2026-11-25 | 123 KB | Download |
| KNX Touch Thermostat 3.0 | $0B88 | 2597 | 2026-11-25 | 123 KB | Download |
About this file
This is the official ETS product database for the VIMAR 02952 KNX Touch Thermostat (02952), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.
More from VIMAR
- 02972 KNX Rotary Dial Thermostat 02972
- 21814 KNX Tactil Thermostat 21814
- 30571 KNX Rotary Dial Thermostat 30571
- 32142 Device XT KNX Secure Multisensor 2M 32142
- 01500.1 Power supply,320mA,MDRC 01500.1
- 01500.2 Power supply unit 320mA KNX 01500.2
- 01501.1 Power supply,640mA,MDRC 01501.1
- 01501.2 Power supply unit 640mA KNX 01501.2
- 01504.1 Line-/Area Coupler, MDRC 01504.1
- 01504.2 Line coupler 01504.2
- 01506 By-me Plus KNX Secure TP router 01506
- 01507 By-me Plus KNX Secure IP router 01507