JMG 4 T 4930250
Theben AG · Order number 4930250 · Ausgabe › JMG 4 T
4 x MIX2 blind actuator
Download .knxprod MIX 2 V1.C (1.12) 1.12 · 3.5 MB
Product
| Manufacturer | Theben AG |
|---|---|
| Product name | JMG 4 T |
| Order number | 4930250 |
| Product text | JMG 4 T (4 x blind actuator) |
| Hardware | MIX 2 Series JMG 4 T |
| Medium | Twisted Pair |
| Bus current (mA) | 5 |
| Rail mounted | Yes |
| Width (mm) | 72 |
| Registration | Certified · 2018-04-20 |
| Languages | de-DE, en-US, es-ES, fr-FR, it-IT, nl-NL, pl-PL |
| Catalog entry | M-0048_H-4930250-1_HP-493A-1C-E04E_CI-4930250-1 |
| Fingerprint | E04E |
| SHA-256 | 053b32fbe50a6fda6df5e629bfccefe6209b70517605db9727941b095fd41eb9 |
| First seen | 2026-11-25 |
| Markets | 59 markets |
Application program: MIX 2 V1.C (1.12) 1.12
| Application number | $493A |
|---|---|
| Version | 1.12 |
| Mask version | MV-0701 (7.1) |
| KNX Data Secure | No |
| Minimum ETS version | 4.0 |
| Parameters | 23627 |
| Group objects | 4230 |
Group objects (4230)
| No | Name | Function | Size | DPT | Flags |
|---|---|---|---|---|---|
| 0 | RMG 4 I channel C1 | Threshold value in % | 1 Byte | CRW | |
| 0 | RMG 4 I channel C1 | Threshold value 0..255 | 1 Byte | CRW | |
| 0 | RMG 4 I channel C1 | Thresh. value EIS 5 (DPT9.xxx) | 2 Bytes | CRW | |
| 0 | RMG 4 I channel C1 | Threshold value 0..65535 | 2 Bytes | CRW | |
| 0 | RMG 4 I channel C1 | Switching object | 1 Bit | CRW | |
| 0 | RMG 8 S channel C1 | Threshold value in % | 1 Byte | CRW | |
| 0 | RMG 8 S channel C1 | Threshold value 0..255 | 1 Byte | CRW | |
| 0 | RMG 8 S channel C1 | Thresh. value EIS 5 (DPT9.xxx) | 2 Bytes | CRW | |
| 0 | RMG 8 S channel C1 | Threshold value 0..65535 | 2 Bytes | CRW | |
| 0 | RMG 8 S channel C1 | Switching object | 1 Bit | CRW | |
| 0 | DMG 2 T channel C1 | Switching ON/OFF | 1 Bit | CRWU | |
| 0 | JMG 4 T channel C1 | UP / DOWN | 1 Bit | CRWU | |
| 0 | RMG 4 U Channel C1 | Switching object | 1 Bit | CRW | |
| 0 | RMG 4 U Channel C1 | Threshold value in % | 1 Byte | CRW | |
| 0 | RMG 4 U Channel C1 | Threshold value 0..255 | 1 Byte | CRW | |
| 0 | RMG 4 U Channel C1 | Thresh. value EIS 5 (DPT9.xxx) | 2 Bytes | CRW | |
| 0 | RMG 4 U Channel C1 | Threshold value 0..65535 | 2 Bytes | CRW | |
| 0 | HMG 6 T Channel H1 | Continuous actuating value | 1 Byte | CRWU | |
| 0 | HMG 6 T Channel H1 | Switching actuating value | 1 Bit | CRWU | |
| 0 | HMG 6 T Channel H1 | Base setpoint value | 2 Bytes | CRW | |
| 0 | RMG 8 T Channel C1 | UP / DOWN | 1 Bit | CRWU | |
| 0 | RMG 8 T Channel C1 | Threshold value in % | 1 Byte | CRW | |
| 0 | RMG 8 T Channel C1 | Threshold value 0..255 | 1 Byte | CRW | |
| 0 | RMG 8 T Channel C1 | Thresh. value EIS 5 (DPT9.xxx) | 2 Bytes | CRW | |
| 0 | RMG 8 T Channel C1 | Threshold value 0..65535 | 2 Bytes | CRW | |
| 0 | RMG 8 T Channel C1 | Switching object | 1 Bit | CRW | |
| 0 | BMG 6 T Channel I1 | Comparison value reached | 1 Bit | CRTU | |
| 0 | BMG 6 T Channel I1 | Transmit counter value | 2 Bytes | CRTU | |
| 0 | BMG 6 T Channel I1 | Switching ON/OFF | 1 Bit | CRWTU | |
| 0 | BMG 6 T Channel I1 | Step / stop | 1 Bit | CRTU | |
| 0 | BMG 6 T Channel I1.1 | Priority | 2 Bit | CRTU | |
| 0 | BMG 6 T Channel I1.1 | Switching ON/OFF | 1 Bit | CRWTU | |
| 0 | BMG 6 T Channel I1.1 | Transmit percentage | 1 Byte | CRTU | |
| 0 | BMG 6 T Channel I1.1 | 4 byte DPT 14.x | 4 Bytes | CRTU | |
| 0 | BMG 6 T Channel I1.1 | 2 byte DPT 9.x | 2 Bytes | CRTU | |
| 0 | BMG 6 T Channel I1.1 | Transmit value | 1 Byte | CRTU | |
| 0 | BMG 6 T Channel I1.1 | Switching ON/OFF | 1 Bit | CRTU | |
| 0 | BMG 6 T Channel I1.1 | 2 byte DPT 9.x | 2 Bytes | CRWTU | |
| 0 | BMG 6 T Channel I1.1 | 4 byte DPT 14.x | 4 Bytes | CRWTU | |
| 0 | BMG 6 T Channel I1.1 | Priority | 2 Bit | CRWTU | |
| 0 | BMG 6 T Channel I1.1 | Repeat 1 Byte | 1 Byte | CRWTU | |
| 1 | RMG 4 I channel C1 | Logic input in XOR gate | 1 Bit | CRW | |
| 1 | RMG 4 I channel C1 | Logic input in OR gate | 1 Bit | CRW | |
| 1 | RMG 4 I channel C1 | Logic input in AND gate | 1 Bit | CRW | |
| 1 | RMG 8 S channel C1 | Logic input in XOR gate | 1 Bit | CRW | |
| 1 | RMG 8 S channel C1 | Logic input in OR gate | 1 Bit | CRW | |
| 1 | RMG 8 S channel C1 | Logic input in AND gate | 1 Bit | CRW | |
| 1 | DMG 2 T channel C1 | Brighter/darker | 4 Bit | CRWU | |
| 1 | JMG 4 T channel C1 | Step / stop | 1 Bit | CRWU | |
| 1 | RMG 4 U Channel C1 | Logic input in XOR gate | 1 Bit | CRW | |
| 1 | RMG 4 U Channel C1 | Logic input in OR gate | 1 Bit | CRW | |
| 1 | RMG 4 U Channel C1 | Logic input in AND gate | 1 Bit | CRW | |
| 1 | HMG 6 T Channel H1 | Manual set point offset | 2 Bytes | CRW | |
| 1 | RMG 8 T Channel C1 | Step / stop | 1 Bit | CRWU | |
| 1 | RMG 8 T Channel C1 | Logic input in XOR gate | 1 Bit | CRW | |
| 1 | RMG 8 T Channel C1 | Logic input in OR gate | 1 Bit | CRW | |
| 1 | RMG 8 T Channel C1 | Logic input in AND gate | 1 Bit | CRW | |
| 1 | BMG 6 T Channel I1 | UP | 1 Bit | CRTU | |
| 1 | BMG 6 T Channel I1 | UP / DOWN | 1 Bit | CRWTU | |
| 1 | BMG 6 T Channel I1 | DOWN | 1 Bit | CRTU | |
| 1 | BMG 6 T Channel I1 | Brighter/darker | 4 Bit | CRTU | |
| 1 | BMG 6 T Channel I1 | Darker | 4 Bit | CRWTU | |
| 1 | BMG 6 T Channel I1 | Darker | 4 Bit | CRTU | |
| 1 | BMG 6 T Channel I1 | Brighter | 4 Bit | CRWTU | |
| 1 | BMG 6 T Channel I1 | Brighter | 4 Bit | CRTU | |
| 1 | BMG 6 T Channel I1.2 | Priority | 2 Bit | CRTU | |
| 1 | BMG 6 T Channel I1.2 | Switching ON/OFF | 1 Bit | CRWTU | |
| 1 | BMG 6 T Channel I1.2 | Transmit percentage | 1 Byte | CRTU | |
| 1 | BMG 6 T Channel I1.2 | 4 byte DPT 14.x | 4 Bytes | CRTU | |
| 1 | BMG 6 T Channel I1.2 | 2 byte DPT 9.x | 2 Bytes | CRTU | |
| 1 | BMG 6 T Channel I1.2 | Transmit value | 1 Byte | CRTU | |
| 1 | BMG 6 T Channel I1.2 | Switching ON/OFF | 1 Bit | CRTU | |
| 1 | BMG 6 T Channel I1 | Current counter value | 2 Bytes | CRTU | |
| 2 | RMG 8 S channel C1 | Lock | 1 Bit | CRW | |
| 2 | RMG 4 I channel C1 | Lock | 1 Bit | CRW | |
| 2 | DMG 2 T channel C1 | Dimming value | 1 Byte | CWU | |
| 2 | JMG 4 T channel C1 | % Height | 1 Byte | CRWU | |
| 2 | RMG 4 U Channel C1 | Lock | 1 Bit | CRW | |
| 2 | HMG 6 T Channel H1 | Block valve protection | 1 Bit | CRW | |
| 2 | HMG 6 T Channel H1 | Actual value | 2 Bytes | CRWU | |
| 2 | RMG 8 T Channel C1 | % Height | 1 Byte | CRWU | |
| 2 | RMG 8 T Channel C1 | Lock | 1 Bit | CRW | |
| 2 | BMG 6 T Channel I1.3 | 4 byte DPT 14.x | 4 Bytes | CRTU | |
| 2 | BMG 6 T Channel I1.3 | 2 byte DPT 9.x | 2 Bytes | CRTU | |
| 2 | BMG 6 T Channel I1.3 | Priority | 2 Bit | CRTU | |
| 2 | BMG 6 T Channel I1.3 | Switching ON/OFF | 1 Bit | CRWTU | |
| 2 | BMG 6 T Channel I1.3 | Transmit percentage | 1 Byte | CRTU | |
| 2 | BMG 6 T Channel I1.3 | Transmit value | 1 Byte | CRTU | |
| 2 | BMG 6 T Channel I1.1 | Switching ON/OFF | 1 Bit | CRWTU | |
| 2 | BMG 6 T Channel I1.1 | Transmit percentage | 1 Byte | CRTU | |
| 2 | BMG 6 T Channel I1.1 | Transmit value | 1 Byte | CRTU | |
| 2 | BMG 6 T Channel I1.1 | Height % | 1 Byte | CRTU | |
| 2 | BMG 6 T Channel I1.3 | Switching ON/OFF | 1 Bit | CRTU | |
| 3 | RMG 8 S channel C1 | Call up/save scenes | 1 Byte | CRWTU | |
| 3 | RMG 4 I channel C1 | Call up/save scenes | 1 Byte | CRWTU | |
| 3 | DMG 2 T channel C1 | Soft switching | 1 Bit | CRWU | |
| 3 | JMG 4 T channel C1 | % Lamella | 1 Byte | CRWU | |
| 3 | RMG 4 U Channel C1 | Call up/save scenes | 1 Byte | CRWTU | |
| 3 | HMG 6 T Channel H1 | Current actuating value | 1 Byte | CRTU | |
| 3 | HMG 6 T Channel H1 | Operating mode preset | 1 Byte | CRW | |
| 3 | RMG 8 T Channel C1 | % Lamella | 1 Byte | CRWU | |
| 3 | RMG 8 T Channel C1 | Call up/save scenes | 1 Byte | CRWTU | |
| 3 | BMG 6 T Channel I1.4 | Transmit value | 1 Byte | CRTU | |
| 3 | BMG 6 T Channel I1.4 | Priority | 2 Bit | CRTU | |
| 3 | BMG 6 T Channel I1.4 | Switching ON/OFF | 1 Bit | CRTU | |
| 3 | BMG 6 T Channel I1.4 | Transmit percentage | 1 Byte | CRTU | |
| 3 | BMG 6 T Channel I1.2 | Lamella % | 1 Byte | CRTU | |
| 4 | RMG 8 S channel C1 | Lock scenes = 1 | 1 Bit | CRW | |
| 4 | RMG 8 S channel C1 | Enable scenes = 1 | 1 Bit | CRW | |
| 4 | RMG 4 I channel C1 | Enable scenes = 1 | 1 Bit | CRW | |
| 4 | RMG 4 I channel C1 | Lock scenes = 1 | 1 Bit | CRW | |
| 4 | DMG 2 T channel C1 | Lock | 1 Bit | CRWU | |
| 4 | JMG 4 T channel C1 | Lock comfort/automatic | 1 Bit | CRWU | |
| 4 | RMG 4 U Channel C1 | Lock scenes = 1 | 1 Bit | CRW | |
| 4 | RMG 4 U Channel C1 | Enable scenes = 1 | 1 Bit | CRW | |
| 4 | HMG 6 T Channel H1 | Presence | 1 Bit | CRW | |
| 4 | RMG 8 T Channel C1 | Lock comfort/automatic | 1 Bit | CRWU | |
| 4 | RMG 8 T Channel C1 | Lock scenes = 1 | 1 Bit | CRW | |
| 4 | RMG 8 T Channel C1 | Enable scenes = 1 | 1 Bit | CRW | |
| 4 | BMG 6 T Channel I1 | 1 = enable counter | 1 Bit | CRWU | |
| 4 | BMG 6 T Channel I1 | 1 = lock counter | 1 Bit | CRWU | |
| 4 | BMG 6 T Channel I1 | Disable = 1 | 1 Bit | CRWU | |
| 4 | BMG 6 T Channel I1 | Disable = 0 | 1 Bit | CRWU | |
| 5 | RMG 4 I channel C1 | Feedback ON/OFF | 1 Bit | CRTU | |
| 5 | RMG 8 S channel C1 | Feedback ON/OFF | 1 Bit | CRTU | |
| 5 | DMG 2 T channel C1 | Call up/save scenes | 1 Byte | CRWU | |
| 5 | JMG 4 T channel C1 | 1 = Lock | 1 Bit | CRWU | |
| 5 | JMG 4 T channel C1 | 1 = Release | 1 Bit | CRWU | |
| 5 | RMG 4 U Channel C1 | Feedback ON/OFF | 1 Bit | CRTU | |
| 5 | HMG 6 T Channel H1 | Window position | 1 Bit | CRW | |
| 5 | RMG 8 T Channel C1 | 1 = Lock | 1 Bit | CRWU | |
| 5 | RMG 8 T Channel C1 | 1 = Release | 1 Bit | CRWU | |
| 5 | RMG 8 T Channel C1 | Feedback ON/OFF | 1 Bit | CRTU | |
| 5 | BMG 6 T Channel I1 | Counter reset | 1 Bit | CRWU | |
| 5 | BMG 6 T Channel I1 | Confirm alert | 1 Bit | CRWU | |
| 6 | RMG 8 S channel C1 | Time to next service | 2 Bytes | CRWTU | |
| 6 | RMG 8 S channel C1 | Operating hours feedback | 2 Bytes | CRWT | |
| 6 | RMG 4 I channel C1 | Operating hours feedback | 2 Bytes | CRWT | |
| 6 | RMG 4 I channel C1 | Time to next service | 2 Bytes | CRWTU | |
| 6 | DMG 2 T channel C1 | Lock scenes = 1 | 1 Bit | CRW | |
| 6 | DMG 2 T channel C1 | Enable scenes = 1 | 1 Bit | CRW | |
| 6 | JMG 4 T channel C1 | Call up/save scenes | 1 Byte | CRWU | |
| 6 | RMG 4 U Channel C1 | Time to next service | 2 Bytes | CRWTU | |
| 6 | RMG 4 U Channel C1 | Operating hours feedback | 2 Bytes | CRWT | |
| 6 | HMG 6 T Channel H1 | Current operating mode | 1 Byte | CRT | |
| 6 | RMG 8 T Channel C1 | Call up/save scenes | 1 Byte | CRWU | |
| 6 | RMG 8 T Channel C1 | Operating hours feedback | 2 Bytes | CRWT | |
| 6 | RMG 8 T Channel C1 | Time to next service | 2 Bytes | CRWTU | |
| 7 | RMG 8 S channel C1 | Service required | 1 Bit | CRTU | |
| 7 | RMG 4 I channel C1 | Service required | 1 Bit | CRTU | |
| 7 | DMG 2 T channel C1 | Force = 1 | 1 Bit | CRWU | |
| 7 | DMG 2 T channel C1 | Force = 0 | 1 Bit | CRWU | |
| 7 | DMG 2 T channel C1 | Dimming value with forced op | 1 Byte | CRWU | |
| 7 | DMG 2 T channel C1 | Forced mode | 2 Bit | CRWU | |
| 7 | JMG 4 T channel C1 | Enable scenes = 1 | 1 Bit | CRW | |
| 7 | JMG 4 T channel C1 | Lock scenes = 1 | 1 Bit | CRW | |
| 7 | RMG 4 U Channel C1 | Service required | 1 Bit | CRTU | |
| 7 | HMG 6 T Channel H1 | Heating actuating value | 1 Byte | CRT | |
| 7 | HMG 6 T Channel H1 | Heat & cool actuating values | 1 Byte | CRT | |
| 7 | RMG 8 T Channel C1 | Enable scenes = 1 | 1 Bit | CRW | |
| 7 | RMG 8 T Channel C1 | Lock scenes = 1 | 1 Bit | CRW | |
| 7 | RMG 8 T Channel C1 | Service required | 1 Bit | CRTU | |
| 8 | RMG 8 S channel C1 | Switching with priority | 2 Bit | CRW | |
| 8 | RMG 8 S channel C1 | Reset service | 1 Bit | CRW | |
| 8 | RMG 8 S channel C1 | Reset operating hours | 1 Bit | CRW | |
| 8 | RMG 4 I channel C1 | Reset operating hours | 1 Bit | CRW | |
| 8 | RMG 4 I channel C1 | Reset service | 1 Bit | CRW | |
| 8 | RMG 4 I channel C1 | Switching with priority | 2 Bit | CRW | |
| 8 | DMG 2 T channel C1 | Dimming value limit | 1 Byte | CRWU | |
| 8 | JMG 4 T channel C1 | Priority on safety | 2 Bit | CRWU | |
| 8 | RMG 4 U Channel C1 | Switching with priority | 2 Bit | CRW | |
| 8 | RMG 4 U Channel C1 | Reset service | 1 Bit | CRW | |
| 8 | RMG 4 U Channel C1 | Reset operating hours | 1 Bit | CRW | |
| 8 | HMG 6 T Channel H1 | Cooling actuating value | 1 Byte | CRT | |
| 8 | RMG 8 T Channel C1 | Priority on safety | 2 Bit | CRWU | |
| 8 | RMG 8 T Channel C1 | Reset operating hours | 1 Bit | CRW | |
| 8 | RMG 8 T Channel C1 | Reset service | 1 Bit | CRW | |
| 8 | RMG 8 T Channel C1 | Switching with priority | 2 Bit | CRW | |
| 9 | RMG 4 I channel C1 | Theoretical power | 2 Bytes | CRTU | |
| 9 | RMG 4 I channel C1 | Current value | 2 Bytes | CRTU | |
| 9 | DMG 2 T channel C1 | Feedback On/Off | 1 Bit | CRTU | |
| 9 | JMG 4 T channel C1 | Presence | 1 Bit | CRW | |
| 9 | JMG 4 T channel C1 | Position A | 1 Bit | CRWU | |
| 9 | HMG 6 T Channel H1 | Heating = 1, Cooling = 0 | 1 Bit | DPT.1 | CRW |
| 9 | HMG 6 T Channel H1 | Heating = 0, Cooling = 1 | 1 Bit | 1.1 switch | CRW |
| 9 | HMG 6 T Channel H1 | Forced operation mode | 1 Bit | CRWU | |
| 10 | RMG 8 S channel C2 | Threshold value in % | 1 Byte | CRW | |
| 10 | RMG 8 S channel C2 | Threshold value 0..65535 | 2 Bytes | CRW | |
| 10 | RMG 8 S channel C2 | Threshold value 0..255 | 1 Byte | CRW | |
| 10 | RMG 8 S channel C2 | Thresh. value EIS 5 (DPT9.xxx) | 2 Bytes | CRW | |
| 10 | RMG 8 S channel C2 | Switching object | 1 Bit | CRW | |
| 10 | RMG 4 I channel C1 | Overload | 1 Bit | CRT | |
| 10 | DMG 2 T channel C1 | Feedback in % | 1 Byte | CRTU | |
| 10 | JMG 4 T channel C1 | Heating support | 1 Bit | CRWU | |
| 10 | JMG 4 T channel C1 | Position B | 1 Bit | CRWU | |
| 10 | RMG 4 U Channel C2 | Switching object | 1 Bit | CRW | |
| 10 | RMG 4 U Channel C2 | Threshold value in % | 1 Byte | CRW | |
| 10 | RMG 4 U Channel C2 | Threshold value 0..65535 | 2 Bytes | CRW | |
| 10 | RMG 4 U Channel C2 | Threshold value 0..255 | 1 Byte | CRW | |
| 10 | RMG 4 U Channel C2 | Thresh. value EIS 5 (DPT9.xxx) | 2 Bytes | CRW | |
| 10 | HMG 6 T Channel H1 | Current setpoint value | 2 Bytes | CRWT | |
| 10 | RMG 8 T Channel C2 | UP / DOWN | 1 Bit | CRWU | |
| 10 | RMG 8 T Channel C2 | Threshold value in % | 1 Byte | CRW | |
| 10 | RMG 8 T Channel C2 | Threshold value 0..65535 | 2 Bytes | CRW | |
| 10 | RMG 8 T Channel C2 | Threshold value 0..255 | 1 Byte | CRW | |
| 10 | RMG 8 T Channel C2 | Thresh. value EIS 5 (DPT9.xxx) | 2 Bytes | CRW | |
| 10 | RMG 8 T Channel C2 | Switching object | 1 Bit | CRW | |
| 10 | BMG 6 T Channel I2 | Switching ON/OFF | 1 Bit | CRWTU | |
| 10 | BMG 6 T Channel I2.1 | Priority | 2 Bit | CRTU | |
| 10 | BMG 6 T Channel I2.1 | Switching ON/OFF | 1 Bit | CRWTU | |
| 10 | BMG 6 T Channel I2.1 | Transmit percentage | 1 Byte | CRTU | |
| 10 | BMG 6 T Channel I2.1 | 2 byte DPT 9.x | 2 Bytes | CRTU | |
| 10 | BMG 6 T Channel I2.1 | 4 byte DPT 14.x | 4 Bytes | CRTU | |
| 10 | BMG 6 T Channel I2.1 | Transmit value | 1 Byte | CRTU | |
| 10 | BMG 6 T Channel I2 | Transmit counter value | 2 Bytes | CRTU | |
| 10 | BMG 6 T Channel I2 | Comparison value reached | 1 Bit | CRTU | |
| 10 | BMG 6 T Channel I2.1 | Switching ON/OFF | 1 Bit | CRTU | |
| 10 | BMG 6 T Channel I2.1 | Priority | 2 Bit | CRWTU | |
| 10 | BMG 6 T Channel I2.1 | 4 byte DPT 14.x | 4 Bytes | CRWTU | |
| 10 | BMG 6 T Channel I2.1 | 2 byte DPT 9.x | 2 Bytes | CRWTU | |
| 10 | BMG 6 T Channel I2.1 | Repeat 1 Byte | 1 Byte | CRWTU | |
| 10 | BMG 6 T Channel I2 | Step / stop | 1 Bit | CRTU | |
| 11 | RMG 4 I channel C1 | Underload | 1 Bit | CRT | |
| 11 | RMG 8 S channel C2 | Logic input in XOR gate | 1 Bit | CRW | |
| 11 | RMG 8 S channel C2 | Logic input in OR gate | 1 Bit | CRW | |
| 11 | RMG 8 S channel C2 | Logic input in AND gate | 1 Bit | CRW | |
| 11 | DMG 2 T channel C1 | Time to next service | 2 Bytes | CRWTU | |
| 11 | DMG 2 T channel C1 | Operating hours feedback | 2 Bytes | CRWT | |
| 11 | JMG 4 T channel C1 | Cooling support | 1 Bit | CRWU | |
| 11 | JMG 4 T channel C1 | Position C | 1 Bit | CRWU | |
| 11 | RMG 4 U Channel C2 | Logic input in XOR gate | 1 Bit | CRW | |
| 11 | RMG 4 U Channel C2 | Logic input in OR gate | 1 Bit | CRW | |
| 11 | RMG 4 U Channel C2 | Logic input in AND gate | 1 Bit | CRW | |
| 11 | HMG 6 T Channel H1 | Report actuating value failure | 1 Bit | CRTU | |
| 11 | HMG 6 T Channel H1 | Report actual value failure | 1 Bit | CRTU | |
| 11 | RMG 8 T Channel C2 | Step / stop | 1 Bit | CRWU | |
| 11 | RMG 8 T Channel C2 | Logic input in XOR gate | 1 Bit | CRW | |
| 11 | RMG 8 T Channel C2 | Logic input in OR gate | 1 Bit | CRW | |
| 11 | RMG 8 T Channel C2 | Logic input in AND gate | 1 Bit | CRW | |
| 11 | BMG 6 T Channel I2 | Darker | 4 Bit | CRTU | |
| 11 | BMG 6 T Channel I2 | Brighter | 4 Bit | CRTU | |
| 11 | BMG 6 T Channel I2 | Darker | 4 Bit | CRWTU | |
| 11 | BMG 6 T Channel I2 | Brighter | 4 Bit | CRWTU | |
| 11 | BMG 6 T Channel I2 | Brighter/darker | 4 Bit | CRTU | |
| 11 | BMG 6 T Channel I2.2 | Transmit value | 1 Byte | CRTU | |
| 11 | BMG 6 T Channel I2.2 | Priority | 2 Bit | CRTU | |
| 11 | BMG 6 T Channel I2.2 | Switching ON/OFF | 1 Bit | CRWTU | |
| 11 | BMG 6 T Channel I2.2 | Transmit percentage | 1 Byte | CRTU | |
| 11 | BMG 6 T Channel I2.2 | 4 byte DPT 14.x | 4 Bytes | CRTU | |
| 11 | BMG 6 T Channel I2.2 | 2 byte DPT 9.x | 2 Bytes | CRTU | |
| 11 | BMG 6 T Channel I2.2 | Switching ON/OFF | 1 Bit | CRTU | |
| 11 | BMG 6 T Channel I2 | DOWN | 1 Bit | CRTU | |
| 11 | BMG 6 T Channel I2 | UP / DOWN | 1 Bit | CRWTU | |
| 11 | BMG 6 T Channel I2 | UP | 1 Bit | CRTU | |
| 11 | BMG 6 T Channel I2 | Current counter value | 2 Bytes | CRTU | |
| 12 | RMG 4 I channel C1 | Contact error | 1 Bit | CRTU | |
| 12 | RMG 8 S channel C2 | Lock | 1 Bit | CRW | |
| 12 | DMG 2 T channel C1 | Service required | 1 Bit | CRTU | |
| 12 | JMG 4 T channel C1 | Room temperature | 2 Bytes | CRWU | |
| 12 | RMG 4 U Channel C2 | Lock | 1 Bit | CRW | |
| 12 | HMG 6 T Channel H2 | Continuous actuating value | 1 Byte | CRWU | |
| 12 | HMG 6 T Channel H2 | Switching actuating value | 1 Bit | CRWU | |
| 12 | HMG 6 T Channel H2 | Base setpoint value | 2 Bytes | CRW | |
| 12 | RMG 8 T Channel C2 | % Height | 1 Byte | CRWU | |
| 12 | RMG 8 T Channel C2 | Lock | 1 Bit | CRW | |
| 12 | BMG 6 T Channel I2.1 | Transmit percentage | 1 Byte | CRTU | |
| 12 | BMG 6 T Channel I2.1 | Transmit value | 1 Byte | CRTU | |
| 12 | BMG 6 T Channel I2.1 | Switching ON/OFF | 1 Bit | CRWTU | |
| 12 | BMG 6 T Channel I2.3 | 4 byte DPT 14.x | 4 Bytes | CRTU | |
| 12 | BMG 6 T Channel I2.3 | 2 byte DPT 9.x | 2 Bytes | CRTU | |
| 12 | BMG 6 T Channel I2.3 | Priority | 2 Bit | CRTU | |
| 12 | BMG 6 T Channel I2.3 | Switching ON/OFF | 1 Bit | CRWTU | |
| 12 | BMG 6 T Channel I2.3 | Transmit percentage | 1 Byte | CRTU | |
| 12 | BMG 6 T Channel I2.3 | Transmit value | 1 Byte | CRTU | |
| 12 | BMG 6 T Channel I2.3 | Switching ON/OFF | 1 Bit | CRTU | |
| 12 | BMG 6 T Channel I2.1 | Height % | 1 Byte | CRTU | |
| 13 | JMG 4 T Channel C1 | Height feedback 1 bit | 1 Bit | CRTU | |
| 13 | RMG 4 I channel C1 | Logic input in OR gate | 1 Bit | CRW | |
| 13 | RMG 8 S channel C2 | Call up/save scenes | 1 Byte | CRWTU | |
| 13 | DMG 2 T channel C1 | Reset service | 1 Bit | CRW | |
| 13 | DMG 2 T channel C1 | Reset operating hours | 1 Bit | CRW | |
| 13 | JMG 4 T channel C1 | Height feedback % | 1 Byte | CRTU | |
| 13 | RMG 4 U Channel C2 | Call up/save scenes | 1 Byte | CRWTU | |
| 13 | HMG 6 T Channel H2 | Manual set point offset | 2 Bytes | CRW | |
| 13 | RMG 8 T Channel C2 | % Lamella | 1 Byte | CRWU | |
| 13 | RMG 8 T Channel C2 | Call up/save scenes | 1 Byte | CRWTU | |
| 13 | BMG 6 T Channel I2.4 | Transmit value | 1 Byte | CRTU | |
| 13 | BMG 6 T Channel I2.4 | Priority | 2 Bit | CRTU | |
| 13 | BMG 6 T Channel I2.4 | Transmit percentage | 1 Byte | CRTU | |
| 13 | BMG 6 T Channel I2.4 | Switching ON/OFF | 1 Bit | CRTU | |
| 13 | BMG 6 T Channel I2.2 | Lamella % | 1 Byte | CRTU | |
| 14 | RMG 4 I channel C1 | Logic input in OR gate | 1 Bit | CRW | |
| 14 | RMG 8 S channel C2 | Enable scenes = 1 | 1 Bit | CRW | |
| 14 | RMG 8 S channel C2 | Lock scenes = 1 | 1 Bit | CRW | |
| 14 | DMG 2 T channel C1 | General error message | 1 Bit | CRTU | |
| 14 | JMG 4 T channel C1 | Lamella feedback % | 1 Byte | CRTU | |
| 14 | RMG 4 U Channel C2 | Enable scenes = 1 | 1 Bit | CRW | |
| 14 | RMG 4 U Channel C2 | Lock scenes = 1 | 1 Bit | CRW | |
| 14 | HMG 6 T Channel H2 | Block valve protection | 1 Bit | CRW | |
| 14 | HMG 6 T Channel H2 | Actual value | 2 Bytes | CRWU | |
| 14 | RMG 8 T Channel C2 | Lock comfort/automatic | 1 Bit | CRWU | |
| 14 | RMG 8 T Channel C2 | Enable scenes = 1 | 1 Bit | CRW | |
| 14 | RMG 8 T Channel C2 | Lock scenes = 1 | 1 Bit | CRW | |
| 14 | BMG 6 T Channel I2 | Disable = 0 | 1 Bit | CRWU | |
| 14 | BMG 6 T Channel I2 | Disable = 1 | 1 Bit | CRWU | |
| 14 | BMG 6 T Channel I2 | 1 = lock counter | 1 Bit | CRWU | |
| 14 | BMG 6 T Channel I2 | 1 = enable counter | 1 Bit | CRWU | |
| 15 | RMG 8 S channel C2 | Feedback ON/OFF | 1 Bit | CRTU | |
| 15 | DMG 2 T channel C1 | Short circuit message | 1 Bit | CRTU | |
| 15 | Reserve object 15 | Reserve | 2 Bytes | CRWU | |
| 15 | RMG 4 U Channel C2 | Feedback ON/OFF | 1 Bit | CRTU | |
| 15 | HMG 6 T Channel H2 | Current actuating value | 1 Byte | CRTU | |
| 15 | HMG 6 T Channel H2 | Operating mode preset | 1 Byte | CRW | |
| 15 | RMG 8 T Channel C2 | 1 = Lock | 1 Bit | CRWU | |
| 15 | RMG 8 T Channel C2 | 1 = Release | 1 Bit | CRWU | |
| 15 | RMG 8 T Channel C2 | Feedback ON/OFF | 1 Bit | CRTU | |
| 15 | BMG 6 T Channel I2 | Counter reset | 1 Bit | CRWU | |
| 15 | BMG 6 T Channel I2 | Confirm alert | 1 Bit | CRWU | |
| 16 | RMG 8 S channel C2 | Operating hours feedback | 2 Bytes | CRWT | |
| 16 | RMG 8 S channel C2 | Time to next service | 2 Bytes | CRWTU | |
| 16 | DMG 2 T channel C1 | Excess temperature message | 1 Bit | CRTU | |
| 16 | JMG 4 T channel C1 | Start-up mode | 1 Bit | CRWU | |
| 16 | RMG 4 U Channel C2 | Time to next service | 2 Bytes | CRWTU | |
| 16 | RMG 4 U Channel C2 | Operating hours feedback | 2 Bytes | CRWT | |
| 16 | HMG 6 T Channel H2 | Presence | 1 Bit | CRW | |
| 16 | RMG 8 T Channel C2 | Call up/save scenes | 1 Byte | CRWU | |
| 16 | RMG 8 T Channel C2 | Operating hours feedback | 2 Bytes | CRWT | |
| 16 | RMG 8 T Channel C2 | Time to next service | 2 Bytes | CRWTU | |
| 17 | RMG 8 S channel C2 | Service required | 1 Bit | CRTU | |
| 17 | DMG 2 T channel C1 | Mains power failure | 1 Bit | CRTU | |
| 17 | JMG 4 T channel C1 | Receive runtime | 2 Bytes | CRW | |
| 17 | JMG 4 T channel C1 | Send runtime | 2 Bytes | CRT | |
| 17 | RMG 4 U Channel C2 | Service required | 1 Bit | CRTU | |
| 17 | HMG 6 T Channel H2 | Window position | 1 Bit | CRW | |
| 17 | RMG 8 T Channel C2 | Enable scenes = 1 | 1 Bit | CRW | |
| 17 | RMG 8 T Channel C2 | Lock scenes = 1 | 1 Bit | CRW | |
| 17 | RMG 8 T Channel C2 | Service required | 1 Bit | CRTU | |
| 18 | RMG 8 S channel C2 | Reset operating hours | 1 Bit | CRW | |
| 18 | RMG 8 S channel C2 | Reset service | 1 Bit | CRW | |
| 18 | RMG 8 S channel C2 | Switching with priority | 2 Bit | CRW | |
| 18 | DMG 2 T channel C1 | Load type message (R, C/L) | 1 Bit | CRTU | |
| 18 | RMG 4 U Channel C2 | Switching with priority | 2 Bit | CRW | |
| 18 | RMG 4 U Channel C2 | Reset service | 1 Bit | CRW | |
| 18 | RMG 4 U Channel C2 | Reset operating hours | 1 Bit | CRW | |
| 18 | HMG 6 T Channel H2 | Current operating mode | 1 Byte | CRT | |
| 18 | RMG 8 T Channel C2 | Priority on safety | 2 Bit | CRWU | |
| 18 | RMG 8 T Channel C2 | Reset operating hours | 1 Bit | CRW | |
| 18 | RMG 8 T Channel C2 | Reset service | 1 Bit | CRW | |
| 18 | RMG 8 T Channel C2 | Switching with priority | 2 Bit | CRW | |
| 19 | HMG 6 T Channel H2 | Heat & cool actuating values | 1 Byte | CRT | |
| 19 | HMG 6 T Channel H2 | Heating actuating value | 1 Byte | CRT | |
| 20 | RMG 4 I channel C2 | Switching object | 1 Bit | CRW | |
| 20 | RMG 4 I channel C2 | Threshold value in % | 1 Byte | CRW | |
| 20 | RMG 4 I channel C2 | Threshold value 0..255 | 1 Byte | CRW | |
| 20 | RMG 4 I channel C2 | Threshold value 0..65535 | 2 Bytes | CRW | |
| 20 | RMG 4 I channel C2 | Thresh. value EIS 5 (DPT9.xxx) | 2 Bytes | CRW | |
| 20 | RMG 8 S channel C3 | Threshold value 0..255 | 1 Byte | CRW | |
| 20 | RMG 8 S channel C3 | Thresh. value EIS 5 (DPT9.xxx) | 2 Bytes | CRW | |
| 20 | RMG 8 S channel C3 | Threshold value 0..65535 | 2 Bytes | CRW | |
| 20 | RMG 8 S channel C3 | Threshold value in % | 1 Byte | CRW | |
| 20 | RMG 8 S channel C3 | Switching object | 1 Bit | CRW | |
| 20 | JMG 4 T channel C2 | UP / DOWN | 1 Bit | CRWU | |
| 20 | RMG 4 U Channel C3 | Switching object | 1 Bit | CRW | |
| 20 | RMG 4 U Channel C3 | Threshold value 0..255 | 1 Byte | CRW | |
| 20 | RMG 4 U Channel C3 | Thresh. value EIS 5 (DPT9.xxx) | 2 Bytes | CRW | |
| 20 | RMG 4 U Channel C3 | Threshold value 0..65535 | 2 Bytes | CRW | |
| 20 | RMG 4 U Channel C3 | Threshold value in % | 1 Byte | CRW | |
| 20 | HMG 6 T Channel H2 | Cooling actuating value | 1 Byte | CRT | |
| 20 | RMG 8 T Channel C3 | Threshold value 0..255 | 1 Byte | CRW | |
| 20 | RMG 8 T Channel C3 | Thresh. value EIS 5 (DPT9.xxx) | 2 Bytes | CRW | |
| 20 | RMG 8 T Channel C3 | Threshold value 0..65535 | 2 Bytes | CRW | |
| 20 | RMG 8 T Channel C3 | Threshold value in % | 1 Byte | CRW | |
| 20 | RMG 8 T Channel C3 | Switching object | 1 Bit | CRW | |
| 20 | RMG 8 T Channel C3 | UP / DOWN | 1 Bit | CRWU | |
| 20 | BMG 6 T Channel I3 | Switching ON/OFF | 1 Bit | CRWTU | |
| 20 | BMG 6 T Channel I3.1 | Priority | 2 Bit | CRTU | |
| 20 | BMG 6 T Channel I3.1 | Switching ON/OFF | 1 Bit | CRWTU | |
| 20 | BMG 6 T Channel I3.1 | Transmit percentage | 1 Byte | CRTU | |
| 20 | BMG 6 T Channel I3.1 | 2 byte DPT 9.x | 2 Bytes | CRTU | |
| 20 | BMG 6 T Channel I3.1 | 4 byte DPT 14.x | 4 Bytes | CRTU | |
| 20 | BMG 6 T Channel I3.1 | Transmit value | 1 Byte | CRTU | |
| 20 | BMG 6 T Channel I3 | Transmit counter value | 2 Bytes | CRTU | |
| 20 | BMG 6 T Channel I3 | Comparison value reached | 1 Bit | CRTU | |
| 20 | BMG 6 T Channel I3.1 | Switching ON/OFF | 1 Bit | CRTU | |
| 20 | BMG 6 T Channel I3.1 | Priority | 2 Bit | CRWTU | |
| 20 | BMG 6 T Channel I3.1 | 4 byte DPT 14.x | 4 Bytes | CRWTU | |
| 20 | BMG 6 T Channel I3.1 | 2 byte DPT 9.x | 2 Bytes | CRWTU | |
| 20 | BMG 6 T Channel I3.1 | Repeat 1 Byte | 1 Byte | CRWTU | |
| 20 | BMG 6 T Channel I3 | Step / stop | 1 Bit | CRTU | |
| 21 | RMG 4 I channel C2 | Logic input in XOR gate | 1 Bit | CRW | |
| 21 | RMG 4 I channel C2 | Logic input in OR gate | 1 Bit | CRW | |
| 21 | RMG 4 I channel C2 | Logic input in AND gate | 1 Bit | CRW | |
| 21 | RMG 8 S channel C3 | Logic input in XOR gate | 1 Bit | CRW | |
| 21 | RMG 8 S channel C3 | Logic input in OR gate | 1 Bit | CRW | |
| 21 | RMG 8 S channel C3 | Logic input in AND gate | 1 Bit | CRW | |
| 21 | JMG 4 T channel C2 | Step / stop | 1 Bit | CRWU | |
| 21 | RMG 4 U Channel C3 | Logic input in XOR gate | 1 Bit | CRW | |
| 21 | RMG 4 U Channel C3 | Logic input in OR gate | 1 Bit | CRW | |
| 21 | RMG 4 U Channel C3 | Logic input in AND gate | 1 Bit | CRW | |
| 21 | HMG 6 T Channel H1 | Heating = 1, Cooling = 0 | 1 Bit | DPT.1 | CRW |
| 21 | HMG 6 T Channel H2 | Heating = 0, Cooling = 1 | 1 Bit | 1.1 switch | CRW |
| 21 | HMG 6 T Channel H2 | Forced operation mode | 1 Bit | CRWU | |
| 21 | RMG 8 T Channel C3 | Logic input in OR gate | 1 Bit | CRW | |
| 21 | RMG 8 T Channel C3 | Logic input in AND gate | 1 Bit | CRW | |
| 21 | RMG 8 T Channel C3 | Logic input in XOR gate | 1 Bit | CRW | |
| 21 | RMG 8 T Channel C3 | Step / stop | 1 Bit | CRWU | |
| 21 | BMG 6 T Channel I3 | Darker | 4 Bit | CRWTU | |
| 21 | BMG 6 T Channel I3 | Brighter | 4 Bit | CRWTU | |
| 21 | BMG 6 T Channel I3 | Brighter/darker | 4 Bit | CRTU | |
| 21 | BMG 6 T Channel I3 | Darker | 4 Bit | CRTU | |
| 21 | BMG 6 T Channel I3 | Brighter | 4 Bit | CRTU | |
| 21 | BMG 6 T Channel I3.2 | Transmit value | 1 Byte | CRTU | |
| 21 | BMG 6 T Channel I3.2 | Priority | 2 Bit | CRTU | |
| 21 | BMG 6 T Channel I3.2 | Switching ON/OFF | 1 Bit | CRWTU | |
| 21 | BMG 6 T Channel I3.2 | Transmit percentage | 1 Byte | CRTU | |
| 21 | BMG 6 T Channel I3.2 | 4 byte DPT 14.x | 4 Bytes | CRTU | |
| 21 | BMG 6 T Channel I3.2 | 2 byte DPT 9.x | 2 Bytes | CRTU | |
| 21 | BMG 6 T Channel I3.2 | Switching ON/OFF | 1 Bit | CRTU | |
| 21 | BMG 6 T Channel I3 | UP | 1 Bit | CRTU | |
| 21 | BMG 6 T Channel I3 | DOWN | 1 Bit | CRTU | |
| 21 | BMG 6 T Channel I3 | UP / DOWN | 1 Bit | CRWTU | |
| 21 | BMG 6 T Channel I3 | Current counter value | 2 Bytes | CRTU | |
| 22 | RMG 4 I channel C2 | Lock | 1 Bit | CRW | |
| 22 | RMG 8 S channel C3 | Lock | 1 Bit | CRW | |
| 22 | JMG 4 T channel C2 | % Height | 1 Byte | CRWU | |
| 22 | RMG 4 U Channel C3 | Lock | 1 Bit | CRW | |
| 22 | HMG 6 T Channel H2 | Current setpoint value | 2 Bytes | CRWT | |
| 22 | RMG 8 T Channel C3 | Lock | 1 Bit | CRW | |
| 22 | RMG 8 T Channel C3 | % Height | 1 Byte | CRWU | |
| 22 | BMG 6 T Channel I3.1 | Transmit percentage | 1 Byte | CRTU | |
| 22 | BMG 6 T Channel I3.1 | Transmit value | 1 Byte | CRTU | |
| 22 | BMG 6 T Channel I3.1 | Switching ON/OFF | 1 Bit | CRWTU | |
| 22 | BMG 6 T Channel I3.3 | 4 byte DPT 14.x | 4 Bytes | CRTU | |
| 22 | BMG 6 T Channel I3.3 | 2 byte DPT 9.x | 2 Bytes | CRTU | |
| 22 | BMG 6 T Channel I3.3 | Priority | 2 Bit | CRTU | |
| 22 | BMG 6 T Channel I3.3 | Switching ON/OFF | 1 Bit | CRWTU | |
| 22 | BMG 6 T Channel I3.3 | Transmit percentage | 1 Byte | CRTU | |
| 22 | BMG 6 T Channel I3.3 | Transmit value | 1 Byte | CRTU | |
| 22 | BMG 6 T Channel I3.3 | Switching ON/OFF | 1 Bit | CRTU | |
| 22 | BMG 6 T Channel I3.1 | Height % | 1 Byte | CRTU | |
| 23 | RMG 4 I channel C2 | Call up/save scenes | 1 Byte | CRWTU | |
| 23 | RMG 8 S channel C3 | Call up/save scenes | 1 Byte | CRWTU | |
| 23 | JMG 4 T channel C2 | % Lamella | 1 Byte | CRWU | |
| 23 | RMG 4 U Channel C3 | Call up/save scenes | 1 Byte | CRWTU | |
| 23 | HMG 6 T Channel H2 | Report actuating value failure | 1 Bit | CRTU | |
| 23 | HMG 6 T Channel H2 | Report actual value failure | 1 Bit | CRTU | |
| 23 | RMG 8 T Channel C3 | Call up/save scenes | 1 Byte | CRWTU | |
| 23 | RMG 8 T Channel C3 | % Lamella | 1 Byte | CRWU | |
| 23 | BMG 6 T Channel I3.4 | Transmit value | 1 Byte | CRTU | |
| 23 | BMG 6 T Channel I3.4 | Priority | 2 Bit | CRTU | |
| 23 | BMG 6 T Channel I3.4 | Transmit percentage | 1 Byte | CRTU | |
| 23 | BMG 6 T Channel I3.4 | Switching ON/OFF | 1 Bit | CRTU | |
| 23 | BMG 6 T Channel I3.2 | Lamella % | 1 Byte | CRTU | |
| 24 | RMG 4 I channel C2 | Enable scenes = 1 | 1 Bit | CRW | |
| 24 | RMG 4 I channel C2 | Lock scenes = 1 | 1 Bit | CRW | |
| 24 | RMG 8 S channel C3 | Lock scenes = 1 | 1 Bit | CRW | |
| 24 | RMG 8 S channel C3 | Enable scenes = 1 | 1 Bit | CRW | |
| 24 | JMG 4 T channel C2 | Lock comfort/automatic | 1 Bit | CRWU | |
| 24 | RMG 4 U Channel C3 | Lock scenes = 1 | 1 Bit | CRW | |
| 24 | RMG 4 U Channel C3 | Enable scenes = 1 | 1 Bit | CRW | |
| 24 | HMG 6 T Channel H3 | Continuous actuating value | 1 Byte | CRWU | |
| 24 | HMG 6 T Channel H3 | Switching actuating value | 1 Bit | CRWU | |
| 24 | HMG 6 T Channel H3 | Base setpoint value | 2 Bytes | CRW | |
| 24 | RMG 8 T Channel C3 | Lock scenes = 1 | 1 Bit | CRW | |
| 24 | RMG 8 T Channel C3 | Enable scenes = 1 | 1 Bit | CRW | |
| 24 | RMG 8 T Channel C3 | Lock comfort/automatic | 1 Bit | CRWU | |
| 24 | BMG 6 T Channel I3 | Disable = 0 | 1 Bit | CRWU | |
| 24 | BMG 6 T Channel I3 | Disable = 1 | 1 Bit | CRWU | |
| 24 | BMG 6 T Channel I3 | 1 = enable counter | 1 Bit | CRWU | |
| 24 | BMG 6 T Channel I3 | 1 = lock counter | 1 Bit | CRWU | |
| 25 | RMG 4 I channel C2 | Feedback ON/OFF | 1 Bit | CRTU | |
| 25 | RMG 8 S channel C3 | Feedback ON/OFF | 1 Bit | CRTU | |
| 25 | JMG 4 T channel C2 | 1 = Lock | 1 Bit | CRWU | |
| 25 | JMG 4 T channel C2 | 1 = Release | 1 Bit | CRWU | |
| 25 | RMG 4 U Channel C3 | Feedback ON/OFF | 1 Bit | CRTU | |
| 25 | HMG 6 T Channel H3 | Manual set point offset | 2 Bytes | CRW | |
| 25 | RMG 8 T Channel C3 | Feedback ON/OFF | 1 Bit | CRTU | |
| 25 | RMG 8 T Channel C3 | 1 = Lock | 1 Bit | CRWU | |
| 25 | RMG 8 T Channel C3 | 1 = Release | 1 Bit | CRWU | |
| 25 | BMG 6 T Channel I3 | Counter reset | 1 Bit | CRWU | |
| 25 | BMG 6 T Channel I3 | Confirm alert | 1 Bit | CRWU | |
| 26 | RMG 4 I channel C2 | Operating hours feedback | 2 Bytes | CRWT | |
| 26 | RMG 4 I channel C2 | Time to next service | 2 Bytes | CRWTU | |
| 26 | RMG 8 S channel C3 | Operating hours feedback | 2 Bytes | CRWT | |
| 26 | RMG 8 S channel C3 | Time to next service | 2 Bytes | CRWTU | |
| 26 | JMG 4 T channel C2 | Call up/save scenes | 1 Byte | CRWU | |
| 26 | RMG 4 U Channel C3 | Time to next service | 2 Bytes | CRWTU | |
| 26 | RMG 4 U Channel C3 | Operating hours feedback | 2 Bytes | CRWT | |
| 26 | HMG 6 T Channel H3 | Block valve protection | 1 Bit | CRW | |
| 26 | HMG 6 T Channel H3 | Actual value | 2 Bytes | CRWU | |
| 26 | RMG 8 T Channel C3 | Operating hours feedback | 2 Bytes | CRWT | |
| 26 | RMG 8 T Channel C3 | Time to next service | 2 Bytes | CRWTU | |
| 26 | RMG 8 T Channel C3 | Call up/save scenes | 1 Byte | CRWU | |
| 27 | RMG 4 I channel C2 | Service required | 1 Bit | CRTU | |
| 27 | RMG 8 S channel C3 | Service required | 1 Bit | CRTU | |
| 27 | JMG 4 T channel C2 | Enable scenes = 1 | 1 Bit | CRW | |
| 27 | JMG 4 T channel C2 | Lock scenes = 1 | 1 Bit | CRW | |
| 27 | RMG 4 U Channel C3 | Service required | 1 Bit | CRTU | |
| 27 | HMG 6 T Channel H3 | Current actuating value | 1 Byte | CRTU | |
| 27 | HMG 6 T Channel H3 | Operating mode preset | 1 Byte | CRW | |
| 27 | RMG 8 T Channel C3 | Service required | 1 Bit | CRTU | |
| 27 | RMG 8 T Channel C3 | Lock scenes = 1 | 1 Bit | CRW | |
| 27 | RMG 8 T Channel C3 | Enable scenes = 1 | 1 Bit | CRW | |
| 28 | RMG 4 I channel C2 | Reset operating hours | 1 Bit | CRW | |
| 28 | RMG 4 I channel C2 | Reset service | 1 Bit | CRW | |
| 28 | RMG 4 I channel C2 | Switching with priority | 2 Bit | CRW | |
| 28 | RMG 8 S channel C3 | Reset operating hours | 1 Bit | CRW | |
| 28 | RMG 8 S channel C3 | Reset service | 1 Bit | CRW | |
| 28 | RMG 8 S channel C3 | Switching with priority | 2 Bit | CRW | |
| 28 | JMG 4 T channel C2 | Priority on safety | 2 Bit | CRWU | |
| 28 | RMG 4 U Channel C3 | Switching with priority | 2 Bit | CRW | |
| 28 | RMG 4 U Channel C3 | Reset service | 1 Bit | CRW | |
| 28 | RMG 4 U Channel C3 | Reset operating hours | 1 Bit | CRW | |
| 28 | HMG 6 T Channel H3 | Presence | 1 Bit | CRW | |
| 28 | RMG 8 T Channel C3 | Reset operating hours | 1 Bit | CRW | |
| 28 | RMG 8 T Channel C3 | Reset service | 1 Bit | CRW | |
| 28 | RMG 8 T Channel C3 | Switching with priority | 2 Bit | CRW | |
| 28 | RMG 8 T Channel C3 | Priority on safety | 2 Bit | CRWU | |
| 29 | RMG 4 I channel C2 | Current value | 2 Bytes | CRTU | |
| 29 | RMG 4 I channel C2 | Theoretical power | 2 Bytes | CRTU | |
| 29 | JMG 4 T channel C2 | Presence | 1 Bit | CRW | |
| 29 | JMG 4 T channel C2 | Position A | 1 Bit | CRWU | |
| 29 | HMG 6 T Channel H3 | Window position | 1 Bit | CRW | |
| 30 | RMG 4 I channel C2 | Overload | 1 Bit | CRT | |
| 30 | RMG 8 S channel C4 | Threshold value 0..255 | 1 Byte | CRW | |
| 30 | RMG 8 S channel C4 | Thresh. value EIS 5 (DPT9.xxx) | 2 Bytes | CRW | |
| 30 | RMG 8 S channel C4 | Threshold value 0..65535 | 2 Bytes | CRW | |
| 30 | RMG 8 S channel C4 | Threshold value in % | 1 Byte | CRW | |
| 30 | RMG 8 S channel C4 | Switching object | 1 Bit | CRW | |
| 30 | DMG 2 T channel C2 | Switching ON/OFF | 1 Bit | CRWU | |
| 30 | JMG 4 T channel C2 | Heating support | 1 Bit | CRWU | |
| 30 | JMG 4 T channel C2 | Position B | 1 Bit | CRWU | |
| 30 | RMG 4 U Channel C4 | Switching object | 1 Bit | CRW | |
| 30 | RMG 4 U Channel C4 | Threshold value 0..255 | 1 Byte | CRW | |
| 30 | RMG 4 U Channel C4 | Thresh. value EIS 5 (DPT9.xxx) | 2 Bytes | CRW | |
| 30 | RMG 4 U Channel C4 | Threshold value 0..65535 | 2 Bytes | CRW | |
| 30 | RMG 4 U Channel C4 | Threshold value in % | 1 Byte | CRW | |
| 30 | HMG 6 T Channel H3 | Current operating mode | 1 Byte | CRT | |
| 30 | RMG 8 T Channel C4 | Threshold value 0..255 | 1 Byte | CRW | |
| 30 | RMG 8 T Channel C4 | Thresh. value EIS 5 (DPT9.xxx) | 2 Bytes | CRW | |
| 30 | RMG 8 T Channel C4 | Threshold value 0..65535 | 2 Bytes | CRW | |
| 30 | RMG 8 T Channel C4 | Threshold value in % | 1 Byte | CRW | |
| 30 | RMG 8 T Channel C4 | Switching object | 1 Bit | CRW | |
| 30 | RMG 8 T Channel C4 | UP / DOWN | 1 Bit | CRWU | |
| 30 | BMG 6 T Channel I4 | Switching ON/OFF | 1 Bit | CRWTU | |
| 30 | BMG 6 T Channel I4.1 | Priority | 2 Bit | CRTU | |
| 30 | BMG 6 T Channel I4.1 | Switching ON/OFF | 1 Bit | CRWTU | |
| 30 | BMG 6 T Channel I4.1 | Transmit percentage | 1 Byte | CRTU | |
| 30 | BMG 6 T Channel I4.1 | 2 byte DPT 9.x | 2 Bytes | CRTU | |
| 30 | BMG 6 T Channel I4.1 | 4 byte DPT 14.x | 4 Bytes | CRTU | |
| 30 | BMG 6 T Channel I4.1 | Transmit value | 1 Byte | CRTU | |
| 30 | BMG 6 T Channel I4 | Transmit counter value | 2 Bytes | CRTU | |
| 30 | BMG 6 T Channel I4 | Comparison value reached | 1 Bit | CRTU | |
| 30 | BMG 6 T Channel I4.1 | Switching ON/OFF | 1 Bit | CRTU | |
| 30 | BMG 6 T Channel I4.1 | Priority | 2 Bit | CRWTU | |
| 30 | BMG 6 T Channel I4.1 | 4 byte DPT 14.x | 4 Bytes | CRWTU | |
| 30 | BMG 6 T Channel I4.1 | 2 byte DPT 9.x | 2 Bytes | CRWTU | |
| 30 | BMG 6 T Channel I4.1 | Repeat 1 Byte | 1 Byte | CRWTU | |
| 30 | BMG 6 T Channel I4 | Step / stop | 1 Bit | CRTU | |
| 31 | RMG 4 I channel C2 | Underload | 1 Bit | CRT | |
| 31 | RMG 8 S channel C4 | Logic input in XOR gate | 1 Bit | CRW | |
| 31 | RMG 8 S channel C4 | Logic input in OR gate | 1 Bit | CRW | |
| 31 | RMG 8 S channel C4 | Logic input in AND gate | 1 Bit | CRW | |
| 31 | DMG 2 T channel C2 | Brighter/darker | 4 Bit | CRWU | |
| 31 | JMG 4 T channel C2 | Cooling support | 1 Bit | CRWU | |
| 31 | JMG 4 T channel C2 | Position C | 1 Bit | CRWU | |
| 31 | RMG 4 U Channel C4 | Logic input in XOR gate | 1 Bit | CRW | |
| 31 | RMG 4 U Channel C4 | Logic input in OR gate | 1 Bit | CRW | |
| 31 | RMG 4 U Channel C4 | Logic input in AND gate | 1 Bit | CRW | |
| 31 | HMG 6 T Channel H3 | Heat & cool actuating values | 1 Byte | CRT | |
| 31 | HMG 6 T Channel H3 | Heating actuating value | 1 Byte | CRT | |
| 31 | RMG 8 T Channel C4 | Logic input in XOR gate | 1 Bit | CRW | |
| 31 | RMG 8 T Channel C4 | Logic input in OR gate | 1 Bit | CRW | |
| 31 | RMG 8 T Channel C4 | Logic input in AND gate | 1 Bit | CRW | |
| 31 | RMG 8 T Channel C4 | Step / stop | 1 Bit | CRWU | |
| 31 | BMG 6 T Channel I4 | Darker | 4 Bit | CRTU | |
| 31 | BMG 6 T Channel I4 | Brighter | 4 Bit | CRTU | |
| 31 | BMG 6 T Channel I4 | Darker | 4 Bit | CRWTU | |
| 31 | BMG 6 T Channel I4 | Brighter | 4 Bit | CRWTU | |
| 31 | BMG 6 T Channel I4 | Brighter/darker | 4 Bit | CRTU | |
| 31 | BMG 6 T Channel I4.2 | Transmit value | 1 Byte | CRTU | |
| 31 | BMG 6 T Channel I4.2 | Priority | 2 Bit | CRTU | |
| 31 | BMG 6 T Channel I4.2 | Switching ON/OFF | 1 Bit | CRWTU | |
| 31 | BMG 6 T Channel I4.2 | Transmit percentage | 1 Byte | CRTU | |
| 31 | BMG 6 T Channel I4.2 | 4 byte DPT 14.x | 4 Bytes | CRTU | |
| 31 | BMG 6 T Channel I4.2 | 2 byte DPT 9.x | 2 Bytes | CRTU | |
| 31 | BMG 6 T Channel I4.2 | Switching ON/OFF | 1 Bit | CRTU | |
| 31 | BMG 6 T Channel I4 | DOWN | 1 Bit | CRTU | |
| 31 | BMG 6 T Channel I4 | UP / DOWN | 1 Bit | CRWTU | |
| 31 | BMG 6 T Channel I4 | UP | 1 Bit | CRTU | |
| 31 | BMG 6 T Channel I4 | Current counter value | 2 Bytes | CRTU | |
| 32 | RMG 4 I channel C2 | Contact error | 1 Bit | CRTU | |
| 32 | RMG 8 S channel C4 | Lock | 1 Bit | CRW | |
| 32 | DMG 2 T channel C2 | Dimming value | 1 Byte | CWU | |
| 32 | JMG 4 T channel C2 | Room temperature | 2 Bytes | CRWU | |
| 32 | RMG 4 U Channel C4 | Lock | 1 Bit | CRW | |
| 32 | HMG 6 T Channel H3 | Cooling actuating value | 1 Byte | CRT | |
| 32 | RMG 8 T Channel C4 | Lock | 1 Bit | CRW | |
| 32 | RMG 8 T Channel C4 | % Height | 1 Byte | CRWU | |
| 32 | BMG 6 T Channel I4.1 | Transmit percentage | 1 Byte | CRTU | |
| 32 | BMG 6 T Channel I4.1 | Transmit value | 1 Byte | CRTU | |
| 32 | BMG 6 T Channel I4.1 | Switching ON/OFF | 1 Bit | CRWTU | |
| 32 | BMG 6 T Channel I4.3 | 4 byte DPT 14.x | 4 Bytes | CRTU | |
| 32 | BMG 6 T Channel I4.3 | 2 byte DPT 9.x | 2 Bytes | CRTU | |
| 32 | BMG 6 T Channel I4.3 | Priority | 2 Bit | CRTU | |
| 32 | BMG 6 T Channel I4.3 | Switching ON/OFF | 1 Bit | CRWTU | |
| 32 | BMG 6 T Channel I4.3 | Transmit percentage | 1 Byte | CRTU | |
| 32 | BMG 6 T Channel I4.3 | Transmit value | 1 Byte | CRTU | |
| 32 | BMG 6 T Channel I4.3 | Switching ON/OFF | 1 Bit | CRTU | |
| 32 | BMG 6 T Channel I4.1 | Height % | 1 Byte | CRTU | |
| 33 | JMG 4 T Channel C2 | Height feedback 1 bit | 1 Bit | CRTU | |
| 33 | RMG 4 I channel C2 | Logic input in OR gate | 1 Bit | CRW | |
| 33 | RMG 8 S channel C4 | Call up/save scenes | 1 Byte | CRWTU | |
| 33 | DMG 2 T channel C2 | Soft switching | 1 Bit | CRWU | |
| 33 | JMG 4 T channel C2 | Height feedback % | 1 Byte | CRTU | |
| 33 | RMG 4 U Channel C4 | Call up/save scenes | 1 Byte | CRWTU | |
| 33 | HMG 6 T Channel H3 | Heating = 1, Cooling = 0 | 1 Bit | DPT.1 | CRW |
| 33 | HMG 6 T Channel H3 | Heating = 0, Cooling = 1 | 1 Bit | 1.1 switch | CRW |
| 33 | HMG 6 T Channel H3 | Forced operation mode | 1 Bit | CRWU | |
| 33 | RMG 8 T Channel C4 | Call up/save scenes | 1 Byte | CRWTU | |
| 33 | RMG 8 T Channel C4 | % Lamella | 1 Byte | CRWU | |
| 33 | BMG 6 T Channel I4.4 | Transmit value | 1 Byte | CRTU | |
| 33 | BMG 6 T Channel I4.4 | Priority | 2 Bit | CRTU | |
| 33 | BMG 6 T Channel I4.4 | Transmit percentage | 1 Byte | CRTU | |
| 33 | BMG 6 T Channel I4.4 | Switching ON/OFF | 1 Bit | CRTU | |
| 33 | BMG 6 T Channel I4.2 | Lamella % | 1 Byte | CRTU | |
| 34 | RMG 4 I channel C2 | Logic input in OR gate | 1 Bit | CRW | |
| 34 | RMG 8 S channel C4 | Lock scenes = 1 | 1 Bit | CRW | |
| 34 | RMG 8 S channel C4 | Enable scenes = 1 | 1 Bit | CRW | |
| 34 | DMG 2 T channel C2 | Lock | 1 Bit | CRWU | |
| 34 | JMG 4 T channel C2 | Lamella feedback % | 1 Byte | CRTU | |
| 34 | RMG 4 U Channel C4 | Lock scenes = 1 | 1 Bit | CRW | |
| 34 | RMG 4 U Channel C4 | Enable scenes = 1 | 1 Bit | CRW | |
| 34 | HMG 6 T Channel H3 | Current setpoint value | 2 Bytes | CRWT | |
| 34 | RMG 8 T Channel C4 | Lock scenes = 1 | 1 Bit | CRW | |
| 34 | RMG 8 T Channel C4 | Enable scenes = 1 | 1 Bit | CRW | |
| 34 | RMG 8 T Channel C4 | Lock comfort/automatic | 1 Bit | CRWU | |
| 34 | BMG 6 T Channel I4 | Disable = 0 | 1 Bit | CRWU | |
| 34 | BMG 6 T Channel I4 | Disable = 1 | 1 Bit | CRWU | |
| 34 | BMG 6 T Channel I4 | 1 = enable counter | 1 Bit | CRWU | |
| 34 | BMG 6 T Channel I4 | 1 = lock counter | 1 Bit | CRWU | |
| 35 | RMG 8 S channel C4 | Feedback ON/OFF | 1 Bit | CRTU | |
| 35 | DMG 2 T channel C2 | Call up/save scenes | 1 Byte | CRWU | |
| 35 | RMG 4 U Channel C4 | Feedback ON/OFF | 1 Bit | CRTU | |
| 35 | HMG 6 T Channel H3 | Report actuating value failure | 1 Bit | CRTU | |
| 35 | HMG 6 T Channel H3 | Report actual value failure | 1 Bit | CRTU | |
| 35 | RMG 8 T Channel C4 | Feedback ON/OFF | 1 Bit | CRTU | |
| 35 | RMG 8 T Channel C4 | 1 = Release | 1 Bit | CRWU | |
| 35 | RMG 8 T Channel C4 | 1 = Lock | 1 Bit | CRWU | |
| 35 | BMG 6 T Channel I4 | Counter reset | 1 Bit | CRWU | |
| 35 | BMG 6 T Channel I4 | Confirm alert | 1 Bit | CRWU | |
| 36 | RMG 8 S channel C4 | Operating hours feedback | 2 Bytes | CRWT | |
| 36 | RMG 8 S channel C4 | Time to next service | 2 Bytes | CRWTU | |
| 36 | DMG 2 T channel C2 | Enable scenes = 1 | 1 Bit | CRW | |
| 36 | DMG 2 T channel C2 | Lock scenes = 1 | 1 Bit | CRW | |
| 36 | JMG 4 T channel C2 | Start-up mode | 1 Bit | CRWU | |
| 36 | RMG 4 U Channel C4 | Time to next service | 2 Bytes | CRWTU | |
| 36 | RMG 4 U Channel C4 | Operating hours feedback | 2 Bytes | CRWT | |
| 36 | HMG 6 T Channel H4 | Continuous actuating value | 1 Byte | CRWU | |
| 36 | HMG 6 T Channel H4 | Switching actuating value | 1 Bit | CRWU | |
| 36 | HMG 6 T Channel H4 | Base setpoint value | 2 Bytes | CRW | |
| 36 | RMG 8 T Channel C4 | Operating hours feedback | 2 Bytes | CRWT | |
| 36 | RMG 8 T Channel C4 | Time to next service | 2 Bytes | CRWTU | |
| 36 | RMG 8 T Channel C4 | Call up/save scenes | 1 Byte | CRWU | |
| 37 | RMG 8 S channel C4 | Service required | 1 Bit | CRTU | |
| 37 | DMG 2 T channel C2 | Force = 0 | 1 Bit | CRWU | |
| 37 | DMG 2 T channel C2 | Force = 1 | 1 Bit | CRWU | |
| 37 | DMG 2 T channel C2 | Dimming value with forced op | 1 Byte | CRWU | |
| 37 | DMG 2 T channel C2 | Forced mode | 2 Bit | CRWU | |
| 37 | JMG 4 T channel C2 | Receive runtime | 2 Bytes | CRW | |
| 37 | JMG 4 T channel C2 | Send runtime | 2 Bytes | CRT | |
| 37 | RMG 4 U Channel C4 | Service required | 1 Bit | CRTU | |
| 37 | HMG 6 T Channel H4 | Manual set point offset | 2 Bytes | CRW | |
| 37 | RMG 8 T Channel C4 | Service required | 1 Bit | CRTU | |
| 37 | RMG 8 T Channel C4 | Lock scenes = 1 | 1 Bit | CRW | |
| 37 | RMG 8 T Channel C4 | Enable scenes = 1 | 1 Bit | CRW | |
| 38 | RMG 8 S channel C4 | Reset operating hours | 1 Bit | CRW | |
| 38 | RMG 8 S channel C4 | Reset service | 1 Bit | CRW | |
| 38 | RMG 8 S channel C4 | Switching with priority | 2 Bit | CRW | |
| 38 | DMG 2 T channel C2 | Dimming value limit | 1 Byte | CRWU | |
| 38 | RMG 4 U Channel C4 | Switching with priority | 2 Bit | CRW | |
| 38 | RMG 4 U Channel C4 | Reset service | 1 Bit | CRW | |
| 38 | RMG 4 U Channel C4 | Reset operating hours | 1 Bit | CRW | |
| 38 | HMG 6 T Channel H4 | Block valve protection | 1 Bit | CRW | |
| 38 | HMG 6 T Channel H4 | Actual value | 2 Bytes | CRWU | |
| 38 | RMG 8 T Channel C4 | Reset operating hours | 1 Bit | CRW | |
| 38 | RMG 8 T Channel C4 | Reset service | 1 Bit | CRW | |
| 38 | RMG 8 T Channel C4 | Switching with priority | 2 Bit | CRW | |
| 38 | RMG 8 T Channel C4 | Priority on safety | 2 Bit | CRWU | |
| 39 | DMG 2 T channel C2 | Feedback On/Off | 1 Bit | CRTU | |
| 39 | HMG 6 T Channel H4 | Current actuating value | 1 Byte | CRTU | |
| 39 | HMG 6 T Channel H4 | Operating mode preset | 1 Byte | CRW | |
| 40 | RMG 4 I channel C3 | Threshold value 0..255 | 1 Byte | CRW | |
| 40 | RMG 4 I channel C3 | Threshold value in % | 1 Byte | CRW | |
| 40 | RMG 4 I channel C3 | Thresh. value EIS 5 (DPT9.xxx) | 2 Bytes | CRW | |
| 40 | RMG 4 I channel C3 | Threshold value 0..65535 | 2 Bytes | CRW | |
| 40 | RMG 4 I channel C3 | Switching object | 1 Bit | CRW | |
| 40 | RMG 8 S channel C5 | Threshold value 0..255 | 1 Byte | CRW | |
| 40 | RMG 8 S channel C5 | Thresh. value EIS 5 (DPT9.xxx) | 2 Bytes | CRW | |
| 40 | RMG 8 S channel C5 | Threshold value 0..65535 | 2 Bytes | CRW | |
| 40 | RMG 8 S channel C5 | Threshold value in % | 1 Byte | CRW | |
| 40 | RMG 8 S channel C5 | Switching object | 1 Bit | CRW | |
| 40 | DMG 2 T channel C2 | Feedback in % | 1 Byte | CRTU | |
| 40 | JMG 4 T channel C3 | UP / DOWN | 1 Bit | CRWU | |
| 40 | HMG 6 T Channel H4 | Presence | 1 Bit | CRW | |
| 40 | RMG 8 T Channel C1 | Position A | 1 Bit | CRWU | |
| 40 | RMG 8 T Channel C5 | Threshold value 0..255 | 1 Byte | CRW | |
| 40 | RMG 8 T Channel C5 | Thresh. value EIS 5 (DPT9.xxx) | 2 Bytes | CRW | |
| 40 | RMG 8 T Channel C5 | Threshold value 0..65535 | 2 Bytes | CRW | |
| 40 | RMG 8 T Channel C5 | Threshold value in % | 1 Byte | CRW | |
| 40 | RMG 8 T Channel C5 | Switching object | 1 Bit | CRW | |
| 40 | BMG 6 T Channel I5 | Switching ON/OFF | 1 Bit | CRWTU | |
| 40 | BMG 6 T Channel I5.1 | Priority | 2 Bit | CRTU | |
| 40 | BMG 6 T Channel I5.1 | Switching ON/OFF | 1 Bit | CRWTU | |
| 40 | BMG 6 T Channel I5.1 | Transmit percentage | 1 Byte | CRTU | |
| 40 | BMG 6 T Channel I5.1 | 2 byte DPT 9.x | 2 Bytes | CRTU | |
| 40 | BMG 6 T Channel I5.1 | 4 byte DPT 14.x | 4 Bytes | CRTU | |
| 40 | BMG 6 T Channel I5.1 | Transmit value | 1 Byte | CRTU | |
| 40 | BMG 6 T Channel I5 | Transmit counter value | 2 Bytes | CRTU | |
| 40 | BMG 6 T Channel I5 | Comparison value reached | 1 Bit | CRTU | |
| 40 | BMG 6 T Channel I5.1 | Switching ON/OFF | 1 Bit | CRTU | |
| 40 | BMG 6 T Channel I5.1 | Priority | 2 Bit | CRWTU | |
| 40 | BMG 6 T Channel I5.1 | 4 byte DPT 14.x | 4 Bytes | CRWTU | |
| 40 | BMG 6 T Channel I5.1 | 2 byte DPT 9.x | 2 Bytes | CRWTU | |
| 40 | BMG 6 T Channel I5.1 | Repeat 1 Byte | 1 Byte | CRWTU | |
| 40 | BMG 6 T Channel I5 | Step / stop | 1 Bit | CRTU | |
| 41 | RMG 4 I channel C3 | Logic input in XOR gate | 1 Bit | CRW | |
| 41 | RMG 4 I channel C3 | Logic input in OR gate | 1 Bit | CRW | |
| 41 | RMG 4 I channel C3 | Logic input in AND gate | 1 Bit | CRW | |
| 41 | RMG 8 S channel C5 | Logic input in XOR gate | 1 Bit | CRW | |
| 41 | RMG 8 S channel C5 | Logic input in AND gate | 1 Bit | CRW | |
| 41 | RMG 8 S channel C5 | Logic input in OR gate | 1 Bit | CRW | |
| 41 | DMG 2 T channel C2 | Time to next service | 2 Bytes | CRWTU | |
| 41 | DMG 2 T channel C2 | Operating hours feedback | 2 Bytes | CRWT | |
| 41 | JMG 4 T channel C3 | Step / stop | 1 Bit | CRWU | |
| 41 | HMG 6 T Channel H4 | Window position | 1 Bit | CRW | |
| 41 | RMG 8 T Channel C1 | Position B | 1 Bit | CRWU | |
| 41 | RMG 8 T Channel C5 | Logic input in XOR gate | 1 Bit | CRW | |
| 41 | RMG 8 T Channel C5 | Logic input in AND gate | 1 Bit | CRW | |
| 41 | RMG 8 T Channel C5 | Logic input in OR gate | 1 Bit | CRW | |
| 41 | BMG 6 T Channel I5 | Darker | 4 Bit | CRWTU | |
| 41 | BMG 6 T Channel I5 | Brighter | 4 Bit | CRWTU | |
| 41 | BMG 6 T Channel I5 | Brighter/darker | 4 Bit | CRTU | |
| 41 | BMG 6 T Channel I5 | Darker | 4 Bit | CRTU | |
| 41 | BMG 6 T Channel I5 | Brighter | 4 Bit | CRTU | |
| 41 | BMG 6 T Channel I5.2 | Transmit value | 1 Byte | CRTU | |
| 41 | BMG 6 T Channel I5.2 | Priority | 2 Bit | CRTU | |
| 41 | BMG 6 T Channel I5.2 | Switching ON/OFF | 1 Bit | CRWTU | |
| 41 | BMG 6 T Channel I5.2 | Transmit percentage | 1 Byte | CRTU | |
| 41 | BMG 6 T Channel I5.2 | 4 byte DPT 14.x | 4 Bytes | CRTU | |
| 41 | BMG 6 T Channel I5.2 | 2 byte DPT 9.x | 2 Bytes | CRTU | |
| 41 | BMG 6 T Channel I5.2 | Switching ON/OFF | 1 Bit | CRTU | |
| 41 | BMG 6 T Channel I5 | UP | 1 Bit | CRTU | |
| 41 | BMG 6 T Channel I5 | DOWN | 1 Bit | CRTU | |
| 41 | BMG 6 T Channel I5 | UP / DOWN | 1 Bit | CRWTU | |
| 41 | BMG 6 T Channel I5 | Current counter value | 2 Bytes | CRTU | |
| 42 | RMG 8 S channel C5 | Lock | 1 Bit | CRW | |
| 42 | RMG 4 I channel C3 | Lock | 1 Bit | CRW | |
| 42 | DMG 2 T channel C2 | Service required | 1 Bit | CRTU | |
| 42 | JMG 4 T channel C3 | % Height | 1 Byte | CRWU | |
| 42 | HMG 6 T Channel H4 | Current operating mode | 1 Byte | CRT | |
| 42 | RMG 8 T Channel C1 | Position C | 1 Bit | CRWU | |
| 42 | RMG 8 T Channel C5 | Lock | 1 Bit | CRW | |
| 42 | BMG 6 T Channel I5.1 | Transmit percentage | 1 Byte | CRTU | |
| 42 | BMG 6 T Channel I5.1 | Transmit value | 1 Byte | CRTU | |
| 42 | BMG 6 T Channel I5.1 | Switching ON/OFF | 1 Bit | CRWTU | |
| 42 | BMG 6 T Channel I5.3 | 4 byte DPT 14.x | 4 Bytes | CRTU | |
| 42 | BMG 6 T Channel I5.3 | 2 byte DPT 9.x | 2 Bytes | CRTU | |
| 42 | BMG 6 T Channel I5.3 | Priority | 2 Bit | CRTU | |
| 42 | BMG 6 T Channel I5.3 | Switching ON/OFF | 1 Bit | CRWTU | |
| 42 | BMG 6 T Channel I5.3 | Transmit percentage | 1 Byte | CRTU | |
| 42 | BMG 6 T Channel I5.3 | Transmit value | 1 Byte | CRTU | |
| 42 | BMG 6 T Channel I5.3 | Switching ON/OFF | 1 Bit | CRTU | |
| 42 | BMG 6 T Channel I5.1 | Height % | 1 Byte | CRTU | |
| 43 | RMG 8 S channel C5 | Call up/save scenes | 1 Byte | CRWTU | |
| 43 | RMG 4 I channel C3 | Call up/save scenes | 1 Byte | CRWTU | |
| 43 | DMG 2 T channel C2 | Reset service | 1 Bit | CRW | |
| 43 | DMG 2 T channel C2 | Reset operating hours | 1 Bit | CRW | |
| 43 | RMG 8 T Channel C1 | Height feedback 1 bit | 1 Bit | CRTU | |
| 43 | JMG 4 T channel C3 | % Lamella | 1 Byte | CRWU | |
| 43 | HMG 6 T Channel H4 | Heat & cool actuating values | 1 Byte | CRT | |
| 43 | HMG 6 T Channel H4 | Heating actuating value | 1 Byte | CRT | |
| 43 | RMG 8 T Channel C1 | Height feedback % | 1 Byte | CRTU | |
| 43 | RMG 8 T Channel C5 | Call up/save scenes | 1 Byte | CRWTU | |
| 43 | BMG 6 T Channel I5.4 | Transmit value | 1 Byte | CRTU | |
| 43 | BMG 6 T Channel I5.4 | Priority | 2 Bit | CRTU | |
| 43 | BMG 6 T Channel I5.4 | Transmit percentage | 1 Byte | CRTU | |
| 43 | BMG 6 T Channel I5.4 | Switching ON/OFF | 1 Bit | CRTU | |
| 43 | BMG 6 T Channel I5.2 | Lamella % | 1 Byte | CRTU | |
| 44 | RMG 4 I channel C3 | Enable scenes = 1 | 1 Bit | CRW | |
| 44 | RMG 8 S channel C5 | Lock scenes = 1 | 1 Bit | CRW | |
| 44 | RMG 8 S channel C5 | Enable scenes = 1 | 1 Bit | CRW | |
| 44 | RMG 4 I channel C3 | Lock scenes = 1 | 1 Bit | CRW | |
| 44 | DMG 2 T channel C2 | General error message | 1 Bit | CRTU | |
| 44 | JMG 4 T channel C3 | Lock comfort/automatic | 1 Bit | CRWU | |
| 44 | HMG 6 T Channel H4 | Cooling actuating value | 1 Byte | CRT | |
| 44 | RMG 8 T Channel C1 | Lamella feedback % | 1 Byte | CRTU | |
| 44 | RMG 8 T Channel C5 | Lock scenes = 1 | 1 Bit | CRW | |
| 44 | RMG 8 T Channel C5 | Enable scenes = 1 | 1 Bit | CRW | |
| 44 | BMG 6 T Channel I5 | Disable = 1 | 1 Bit | CRWU | |
| 44 | BMG 6 T Channel I5 | Disable = 0 | 1 Bit | CRWU | |
| 44 | BMG 6 T Channel I5 | 1 = lock counter | 1 Bit | CRWU | |
| 44 | BMG 6 T Channel I5 | 1 = enable counter | 1 Bit | CRWU | |
| 45 | RMG 8 S channel C5 | Feedback ON/OFF | 1 Bit | CRTU | |
| 45 | RMG 4 I channel C3 | Feedback ON/OFF | 1 Bit | CRTU | |
| 45 | DMG 2 T channel C2 | Short circuit message | 1 Bit | CRTU | |
| 45 | JMG 4 T channel C3 | 1 = Lock | 1 Bit | CRWU | |
| 45 | JMG 4 T channel C3 | 1 = Release | 1 Bit | CRWU | |
| 45 | HMG 6 T Channel H4 | Heating = 1, Cooling = 0 | 1 Bit | DPT.1 | CRW |
| 45 | HMG 6 T Channel H4 | Heating = 0, Cooling = 1 | 1 Bit | 1.1 switch | CRW |
| 45 | HMG 6 T Channel H4 | Forced operation mode | 1 Bit | CRWU | |
| 45 | RMG 8 T Channel C5 | Feedback ON/OFF | 1 Bit | CRTU | |
| 45 | BMG 6 T Channel I5 | Counter reset | 1 Bit | CRWU | |
| 45 | BMG 6 T Channel I5 | Confirm alert | 1 Bit | CRWU | |
| 46 | RMG 4 I channel C3 | Operating hours feedback | 2 Bytes | CRWT | |
| 46 | RMG 4 I channel C3 | Time to next service | 2 Bytes | CRWTU | |
| 46 | RMG 8 S channel C5 | Operating hours feedback | 2 Bytes | CRWT | |
| 46 | RMG 8 S channel C5 | Time to next service | 2 Bytes | CRWTU | |
| 46 | DMG 2 T channel C2 | Excess temperature message | 1 Bit | CRTU | |
| 46 | JMG 4 T channel C3 | Call up/save scenes | 1 Byte | CRWU | |
| 46 | HMG 6 T Channel H4 | Current setpoint value | 2 Bytes | CRWT | |
| 46 | RMG 8 T Channel C5 | Operating hours feedback | 2 Bytes | CRWT | |
| 46 | RMG 8 T Channel C5 | Time to next service | 2 Bytes | CRWTU | |
| 47 | RMG 4 I channel C3 | Service required | 1 Bit | CRTU | |
| 47 | RMG 8 S channel C5 | Service required | 1 Bit | CRTU | |
| 47 | DMG 2 T channel C2 | Mains power failure | 1 Bit | CRTU | |
| 47 | JMG 4 T channel C3 | Lock scenes = 1 | 1 Bit | CRW | |
| 47 | JMG 4 T channel C3 | Enable scenes = 1 | 1 Bit | CRW | |
| 47 | HMG 6 T Channel H4 | Report actuating value failure | 1 Bit | CRTU | |
| 47 | HMG 6 T Channel H4 | Report actual value failure | 1 Bit | CRTU | |
| 47 | RMG 8 T Channel C5 | Service required | 1 Bit | CRTU | |
| 48 | RMG 4 I channel C3 | Reset operating hours | 1 Bit | CRW | |
| 48 | RMG 4 I channel C3 | Reset service | 1 Bit | CRW | |
| 48 | RMG 4 I channel C3 | Switching with priority | 2 Bit | CRW | |
| 48 | RMG 8 S channel C5 | Reset operating hours | 1 Bit | CRW | |
| 48 | RMG 8 S channel C5 | Reset service | 1 Bit | CRW | |
| 48 | RMG 8 S channel C5 | Switching with priority | 2 Bit | CRW | |
| 48 | DMG 2 T channel C2 | Load type message (R, C/L) | 1 Bit | CRTU | |
| 48 | JMG 4 T channel C3 | Priority on safety | 2 Bit | CRWU | |
| 48 | HMG 6 T Channel H5 | Continuous actuating value | 1 Byte | CRWU | |
| 48 | HMG 6 T Channel H5 | Switching actuating value | 1 Bit | CRWU | |
| 48 | HMG 6 T Channel H5 | Base setpoint value | 2 Bytes | CRW | |
| 48 | RMG 8 T Channel C5 | Reset operating hours | 1 Bit | CRW | |
| 48 | RMG 8 T Channel C5 | Reset service | 1 Bit | CRW | |
| 48 | RMG 8 T Channel C5 | Switching with priority | 2 Bit | CRW | |
| 49 | RMG 4 I channel C3 | Current value | 2 Bytes | CRTU | |
| 49 | RMG 4 I channel C3 | Theoretical power | 2 Bytes | CRTU | |
| 49 | JMG 4 T channel C3 | Presence | 1 Bit | CRW | |
| 49 | JMG 4 T channel C3 | Position A | 1 Bit | CRWU | |
| 49 | HMG 6 T Channel H5 | Manual set point offset | 2 Bytes | CRW | |
| 50 | RMG 8 S channel C6 | Threshold value 0..255 | 1 Byte | CRW | |
| 50 | RMG 8 S channel C6 | Thresh. value EIS 5 (DPT9.xxx) | 2 Bytes | CRW | |
| 50 | RMG 8 S channel C6 | Threshold value 0..65535 | 2 Bytes | CRW | |
| 50 | RMG 8 S channel C6 | Threshold value in % | 1 Byte | CRW | |
| 50 | RMG 8 S channel C6 | Switching object | 1 Bit | CRW | |
| 50 | RMG 4 I channel C3 | Overload | 1 Bit | CRT | |
| 50 | JMG 4 T channel C3 | Heating support | 1 Bit | CRWU | |
| 50 | JMG 4 T channel C3 | Position B | 1 Bit | CRWU | |
| 50 | HMG 6 T Channel H5 | Block valve protection | 1 Bit | CRW | |
| 50 | HMG 6 T Channel H5 | Actual value | 2 Bytes | CRWU | |
| 50 | RMG 8 T Channel C2 | Position A | 1 Bit | CRWU | |
| 50 | RMG 8 T Channel C6 | Threshold value 0..255 | 1 Byte | CRW | |
| 50 | RMG 8 T Channel C6 | Thresh. value EIS 5 (DPT9.xxx) | 2 Bytes | CRW | |
| 50 | RMG 8 T Channel C6 | Threshold value 0..65535 | 2 Bytes | CRW | |
| 50 | RMG 8 T Channel C6 | Threshold value in % | 1 Byte | CRW | |
| 50 | RMG 8 T Channel C6 | Switching object | 1 Bit | CRW | |
| 50 | BMG 6 T Channel I6 | Switching ON/OFF | 1 Bit | CRWTU | |
| 50 | BMG 6 T Channel I6.1 | Priority | 2 Bit | CRTU | |
| 50 | BMG 6 T Channel I6.1 | Switching ON/OFF | 1 Bit | CRWTU | |
| 50 | BMG 6 T Channel I6.1 | Transmit percentage | 1 Byte | CRTU | |
| 50 | BMG 6 T Channel I6.1 | 2 byte DPT 9.x | 2 Bytes | CRTU | |
| 50 | BMG 6 T Channel I6.1 | 4 byte DPT 14.x | 4 Bytes | CRTU | |
| 50 | BMG 6 T Channel I6.1 | Transmit value | 1 Byte | CRTU | |
| 50 | BMG 6 T Channel I6 | Transmit counter value | 2 Bytes | CRTU | |
| 50 | BMG 6 T Channel I6 | Comparison value reached | 1 Bit | CRTU | |
| 50 | BMG 6 T Channel I6.1 | Switching ON/OFF | 1 Bit | CRTU | |
| 50 | BMG 6 T Channel I6.1 | Priority | 2 Bit | CRWTU | |
| 50 | BMG 6 T Channel I6.1 | 4 byte DPT 14.x | 4 Bytes | CRWTU | |
| 50 | BMG 6 T Channel I6.1 | 2 byte DPT 9.x | 2 Bytes | CRWTU | |
| 50 | BMG 6 T Channel I6.1 | Repeat 1 Byte | 1 Byte | CRWTU | |
| 50 | BMG 6 T Channel I6 | Step / stop | 1 Bit | CRTU | |
| 51 | RMG 4 I channel C3 | Underload | 1 Bit | CRT | |
| 51 | RMG 8 S channel C6 | Logic input in OR gate | 1 Bit | CRW | |
| 51 | RMG 8 S channel C6 | Logic input in XOR gate | 1 Bit | CRW | |
| 51 | RMG 8 S channel C6 | Logic input in AND gate | 1 Bit | CRW | |
| 51 | JMG 4 T channel C3 | Cooling support | 1 Bit | CRWU | |
| 51 | JMG 4 T channel C3 | Position C | 1 Bit | CRWU | |
| 51 | HMG 6 T Channel H5 | Current actuating value | 1 Byte | CRTU | |
| 51 | HMG 6 T Channel H5 | Operating mode preset | 1 Byte | CRW | |
| 51 | RMG 8 T Channel C2 | Position B | 1 Bit | CRWU | |
| 51 | RMG 8 T Channel C6 | Logic input in OR gate | 1 Bit | CRW | |
| 51 | RMG 8 T Channel C6 | Logic input in XOR gate | 1 Bit | CRW | |
| 51 | RMG 8 T Channel C6 | Logic input in AND gate | 1 Bit | CRW | |
| 51 | BMG 6 T Channel I6 | Darker | 4 Bit | CRWTU | |
| 51 | BMG 6 T Channel I6 | Brighter | 4 Bit | CRWTU | |
| 51 | BMG 6 T Channel I6 | Brighter/darker | 4 Bit | CRTU | |
| 51 | BMG 6 T Channel I6 | Darker | 4 Bit | CRTU | |
| 51 | BMG 6 T Channel I6 | Brighter | 4 Bit | CRTU | |
| 51 | BMG 6 T Channel I6.2 | Transmit value | 1 Byte | CRTU | |
| 51 | BMG 6 T Channel I6.2 | Priority | 2 Bit | CRTU | |
| 51 | BMG 6 T Channel I6.2 | Switching ON/OFF | 1 Bit | CRWTU | |
| 51 | BMG 6 T Channel I6.2 | Transmit percentage | 1 Byte | CRTU | |
| 51 | BMG 6 T Channel I6.2 | 4 byte DPT 14.x | 4 Bytes | CRTU | |
| 51 | BMG 6 T Channel I6.2 | 2 byte DPT 9.x | 2 Bytes | CRTU | |
| 51 | BMG 6 T Channel I6.2 | Switching ON/OFF | 1 Bit | CRTU | |
| 51 | BMG 6 T Channel I6 | UP | 1 Bit | CRTU | |
| 51 | BMG 6 T Channel I6 | DOWN | 1 Bit | CRTU | |
| 51 | BMG 6 T Channel I6 | UP / DOWN | 1 Bit | CRWTU | |
| 51 | BMG 6 T Channel I6 | Current counter value | 2 Bytes | CRTU | |
| 52 | RMG 8 S channel C6 | Lock | 1 Bit | CRW | |
| 52 | RMG 4 I channel C3 | Contact error | 1 Bit | CRTU | |
| 52 | JMG 4 T channel C3 | Room temperature | 2 Bytes | CRWU | |
| 52 | HMG 6 T Channel H5 | Presence | 1 Bit | CRW | |
| 52 | RMG 8 T Channel C2 | Position C | 1 Bit | CRWU | |
| 52 | RMG 8 T Channel C6 | Lock | 1 Bit | CRW | |
| 52 | BMG 6 T Channel I6.1 | Transmit percentage | 1 Byte | CRTU | |
| 52 | BMG 6 T Channel I6.1 | Transmit value | 1 Byte | CRTU | |
| 52 | BMG 6 T Channel I6.1 | Switching ON/OFF | 1 Bit | CRWTU | |
| 52 | BMG 6 T Channel I6.3 | 4 byte DPT 14.x | 4 Bytes | CRTU | |
| 52 | BMG 6 T Channel I6.3 | 2 byte DPT 9.x | 2 Bytes | CRTU | |
| 52 | BMG 6 T Channel I6.3 | Priority | 2 Bit | CRTU | |
| 52 | BMG 6 T Channel I6.3 | Switching ON/OFF | 1 Bit | CRWTU | |
| 52 | BMG 6 T Channel I6.3 | Transmit percentage | 1 Byte | CRTU | |
| 52 | BMG 6 T Channel I6.3 | Transmit value | 1 Byte | CRTU | |
| 52 | BMG 6 T Channel I6.3 | Switching ON/OFF | 1 Bit | CRTU | |
| 52 | BMG 6 T Channel I6.1 | Height % | 1 Byte | CRTU | |
| 53 | JMG 4 T Channel C3 | Height feedback 1 bit | 1 Bit | CRTU | |
| 53 | RMG 4 I channel C3 | Logic input in OR gate | 1 Bit | CRW | |
| 53 | RMG 8 S channel C6 | Call up/save scenes | 1 Byte | CRWTU | |
| 53 | RMG 8 T Channel C2 | Height feedback 1 bit | 1 Bit | CRTU | |
| 53 | JMG 4 T channel C3 | Height feedback % | 1 Byte | CRTU | |
| 53 | HMG 6 T Channel H5 | Window position | 1 Bit | CRW | |
| 53 | RMG 8 T Channel C2 | Height feedback % | 1 Byte | CRTU | |
| 53 | RMG 8 T Channel C6 | Call up/save scenes | 1 Byte | CRWTU | |
| 53 | BMG 6 T Channel I6.4 | Transmit value | 1 Byte | CRTU | |
| 53 | BMG 6 T Channel I6.4 | Priority | 2 Bit | CRTU | |
| 53 | BMG 6 T Channel I6.4 | Transmit percentage | 1 Byte | CRTU | |
| 53 | BMG 6 T Channel I6.4 | Switching ON/OFF | 1 Bit | CRTU | |
| 53 | BMG 6 T Channel I6.2 | Lamella % | 1 Byte | CRTU | |
| 54 | RMG 4 I channel C3 | Logic input in OR gate | 1 Bit | CRW | |
| 54 | RMG 8 S channel C6 | Lock scenes = 1 | 1 Bit | CRW | |
| 54 | RMG 8 S channel C6 | Enable scenes = 1 | 1 Bit | CRW | |
| 54 | JMG 4 T channel C3 | Lamella feedback % | 1 Byte | CRTU | |
| 54 | HMG 6 T Channel H5 | Current operating mode | 1 Byte | CRT | |
| 54 | RMG 8 T Channel C2 | Lamella feedback % | 1 Byte | CRTU | |
| 54 | RMG 8 T Channel C6 | Lock scenes = 1 | 1 Bit | CRW | |
| 54 | RMG 8 T Channel C6 | Enable scenes = 1 | 1 Bit | CRW | |
| 54 | BMG 6 T Channel I6 | Disable = 0 | 1 Bit | CRWU | |
| 54 | BMG 6 T Channel I6 | Disable = 1 | 1 Bit | CRWU | |
| 54 | BMG 6 T Channel I6 | 1 = enable counter | 1 Bit | CRWU | |
| 54 | BMG 6 T Channel I6 | 1 = lock counter | 1 Bit | CRWU | |
| 55 | RMG 8 S channel C6 | Feedback ON/OFF | 1 Bit | CRTU | |
| 55 | HMG 6 T Channel H5 | Heating actuating value | 1 Byte | CRT | |
| 55 | HMG 6 T Channel H5 | Heat & cool actuating values | 1 Byte | CRT | |
| 55 | RMG 8 T Channel C6 | Feedback ON/OFF | 1 Bit | CRTU | |
| 55 | BMG 6 T Channel I6 | Counter reset | 1 Bit | CRWU | |
| 55 | BMG 6 T Channel I6 | Confirm alert | 1 Bit | CRWU | |
| 56 | RMG 8 S channel C6 | Operating hours feedback | 2 Bytes | CRWT | |
| 56 | RMG 8 S channel C6 | Time to next service | 2 Bytes | CRWTU | |
| 56 | JMG 4 T channel C3 | Start-up mode | 1 Bit | CRWU | |
| 56 | HMG 6 T Channel H5 | Cooling actuating value | 1 Byte | CRT | |
| 56 | RMG 8 T Channel C6 | Operating hours feedback | 2 Bytes | CRWT | |
| 56 | RMG 8 T Channel C6 | Time to next service | 2 Bytes | CRWTU | |
| 57 | RMG 8 S channel C6 | Service required | 1 Bit | CRTU | |
| 57 | JMG 4 T channel C3 | Receive runtime | 2 Bytes | CRW | |
| 57 | JMG 4 T channel C3 | Send runtime | 2 Bytes | CRT | |
| 57 | HMG 6 T Channel H5 | Heating = 1, Cooling = 0 | 1 Bit | DPT.1 | CRW |
| 57 | HMG 6 T Channel H5 | Heating = 0, Cooling = 1 | 1 Bit | 1.1 switch | CRW |
| 57 | HMG 6 T Channel H5 | Forced operation mode | 1 Bit | CRWU | |
| 57 | RMG 8 T Channel C6 | Service required | 1 Bit | CRTU | |
| 58 | RMG 8 S channel C6 | Reset operating hours | 1 Bit | CRW | |
| 58 | RMG 8 S channel C6 | Reset service | 1 Bit | CRW | |
| 58 | RMG 8 S channel C6 | Switching with priority | 2 Bit | CRW | |
| 58 | HMG 6 T Channel H5 | Current setpoint value | 2 Bytes | CRWT | |
| 58 | RMG 8 T Channel C6 | Reset operating hours | 1 Bit | CRW | |
| 58 | RMG 8 T Channel C6 | Reset service | 1 Bit | CRW | |
| 58 | RMG 8 T Channel C6 | Switching with priority | 2 Bit | CRW | |
| 59 | HMG 6 T Channel H5 | Report actuating value failure | 1 Bit | CRTU | |
| 59 | HMG 6 T Channel H5 | Report actual value failure | 1 Bit | CRTU | |
| 60 | RMG 8 S channel C7 | Threshold value 0..255 | 1 Byte | CRW | |
| 60 | RMG 8 S channel C7 | Thresh. value EIS 5 (DPT9.xxx) | 2 Bytes | CRW | |
| 60 | RMG 8 S channel C7 | Threshold value 0..65535 | 2 Bytes | CRW | |
| 60 | RMG 8 S channel C7 | Threshold value in % | 1 Byte | CRW | |
| 60 | RMG 8 S channel C7 | Switching object | 1 Bit | CRW | |
| 60 | RMG 4 I channel C4 | Threshold value 0..255 | 1 Byte | CRW | |
| 60 | RMG 4 I channel C4 | Thresh. value EIS 5 (DPT9.xxx) | 2 Bytes | CRW | |
| 60 | RMG 4 I channel C4 | Threshold value in % | 1 Byte | CRW | |
| 60 | RMG 4 I channel C4 | Threshold value 0..65535 | 2 Bytes | CRW | |
| 60 | RMG 4 I channel C4 | Switching object | 1 Bit | CRW | |
| 60 | JMG 4 T channel C4 | UP / DOWN | 1 Bit | CRWU | |
| 60 | HMG 6 T Channel H6 | Continuous actuating value | 1 Byte | CRWU | |
| 60 | HMG 6 T Channel H6 | Switching actuating value | 1 Bit | CRWU | |
| 60 | HMG 6 T Channel H6 | Base setpoint value | 2 Bytes | CRW | |
| 60 | RMG 8 T Channel C7 | Threshold value 0..255 | 1 Byte | CRW | |
| 60 | RMG 8 T Channel C7 | Thresh. value EIS 5 (DPT9.xxx) | 2 Bytes | CRW | |
| 60 | RMG 8 T Channel C7 | Threshold value 0..65535 | 2 Bytes | CRW | |
| 60 | RMG 8 T Channel C7 | Threshold value in % | 1 Byte | CRW | |
| 60 | RMG 8 T Channel C7 | Switching object | 1 Bit | CRW | |
| 60 | RMG 8 T Channel C3 | Position A | 1 Bit | CRWU | |
| 60 | BMG 6 T Channel C1 | Switching ON/OFF | 1 Bit | CRWTU |
First 1000 of 4230 group objects shown. Download the .knxprod for the full list.
Parameters (594)
| Parameter | Type | Default |
|---|---|---|
| No. Of general parameters | unsignedInt 1…3 | 3 |
| Download 101 | list | yes |
| Object link RMG8 invisible | list | |
| Object link RMG 4 I invisible | list | |
| - | list | Link HMG 6 T |
| - | list | - |
| - | unsignedInt 1…1 | 1 |
| Type of basic module | list | select device.. |
| Type of first extension module | list | not available/inactive |
| Type of second extension module | list | not available/inactive |
| Time for cycl. Transm. of feedback obj. (MIX 1 series, order no.491...) | list | 15 min. |
| Function of manual push button (MIX 2 series, order no.493...) | list | valid until reset via object |
| Manual operation of channels (MIX 2 series, order no.493...) | list | enabled |
| Object link 1. RME 8 invisible | list | |
| Object link 1. RME 4 S 210 invisible | list | |
| Object link 1. DME 2 210 invisible | list | |
| Object link 1. BME 6 210 invisible | list | |
| Object link 1.HME 4 210 invisible | list | |
| Object link 1.JME 4 S 210 invisible | list | |
| Object link 1. RME 4 I invisible | list | |
| Channel function | list | Heating actuator |
| - | list | BMG 6 T |
| Type of actuating value | list | Continuous.. |
| Include in summer mode | list | no |
| Activate valve protection | list | yes |
| Valve protection disable telegram | list | 1 = Block (standard) |
| Execute valve protection | list | Always |
| Monitoring actuating value | list | no |
| Monitor actual value | list | no |
| Activate compulsory function | list | no |
| Sensitivity of the input | list | normal |
| Object link 2. RME 4 S 310 invisible | list | |
| Object link 2. DME 2 310 invisible | list | |
| Object link 2. BME 6 310 invisible | list | |
| Object link 2.HME 4 310 invisible | list | |
| Object link 2.JME 4 S 310 invisible | list | |
| Object link 2. RME 8 invisible | list | |
| Object link 2. RME 4 I invisible | list | |
| Input function | list | push button.. |
| Debounce time | list | 50 ms |
| Lock telegram (if used) | list | lock with 1 (standard) |
| Long keystroke starting from | list | 300 ms |
| Counting at | list | falling edge |
| Reaction when setting the lock | list | ignore lock |
| Function of the input object | list | Lock |
| Reaction when unlocking | list | no reaction |
| Response during bus or mains restoration | list | none |
| Save meter reading in the event of bus and mains failure | list | yes |
| Control | list | standard |
| Reaction when unlocking | list | none |
| Additional functions with double-click | list | no |
| Reset meter reading at download | list | no |
| Control functions used | list | Only heating control |
| Setting the control parameters | list | Via installation type |
| Proportional band of heating control | list | 2 K |
| Connected push button | list | NO contact |
| System type | list | Radiator heating system |
| Integrated time of heating control | list | 10 hrs |
| Use channel as fault indicator input | list | no |
| Operation | list | UP |
| Reaction to long / short | list | single-button operation |
| Object 1 type | list | percentage value (1 byte) |
| Report fault | list | with rising edge |
| Movement is stopped by | list | brief operation |
| Increment for dimmer | list | 100% |
| Time for double-click | list | 300 ms |
| Confirmation mandatory | list | no |
| Object 2 type | list | switching (1-bit) |
| Send heating actuating value | list | With change of 5 % |
| Send current actuating value | list | With change of 5 % |
| Effect of the confirmation object | list | confirm with 1 |
| Object 3 type | list | switching (1-bit) |
| Transmission of central feedback | list | no |
| Send heating actuating value in cycles | list | Not cyclical, only in the event of change |
| Send current actuating value in cycles | list | Not cyclical, only in the event of change |
| Function Channel C1 | list | switch actuator |
| Update after confirmation if error still present | list | 1 h |
| Cycle time | list | 15 min. |
| Object 4 type | list | percentage value (1 byte) |
| Time for cyclical transmission of collective feedback | list | 2 min. |
| Relay switching delay | list | none |
| Activate lock function | list | no |
| Function Channel C2 | list | switch actuator |
| Sequence details | list | step 1-2-3-4-1-2-3-4 |
| Save object value in the event of bus and mains failure | list | yes |
| With a long button push | list | set on step 1 |
| Delete object value at download | list | yes |
| Function Channel C3 | list | switch actuator |
| Response after bus and mains restoration | list | none |
| Base setpoint value after loading the application | list | 21 °C |
| Object type | list | switching (1-bit) |
| Object type | list | 1 bit (e.g. switching) |
| Reduction in standby mode (during heating) | list | 1.5 K |
| Function Channel C4 | list | switch actuator |
| After short operation | list | send telegram |
| Nach kurzer Bedienung | list | repeat last telegram |
| Send if input = 1 (or fault active) | list | yes |
| Reduction in night mode (during heating) | list | 5 K |
| Telegram | list | inactive |
| Value | signedInt -999…999 | 0 |
| Telegram | list | ON |
| Telegram | list | 100% |
| Value | signedInt -999…999 | 22 |
| Telegram | unsignedInt 0…255 | 255 |
| Telegram | list | OFF |
| Telegram | list | 0% |
| Telegram | unsignedInt 0…255 | 1 |
| Height | list | 0% |
| Value | signedInt -999…999 | 25 |
| Telegram | unsignedInt 0…255 | 25 |
| Setpoint value for frost protection operation (during heating) | list | 5 °C |
| Function Channel C5 | list | allocated to C1 blind actuator |
| Function Channel C5 | list | switch actuator |
| Prescaler | unsignedInt 1…1000 | 1 |
| Factor | list | 1 |
| Lamella | list | 75% |
| Setpoint offset applies | list | In comfort, standby and night mode |
| Current setpoint value in comfort mode | list | Sends actual value (heating < > cooling) |
| Counter type | list | event counter |
| Transmit telegram cyclically | list | no |
| Send current setpoint value in cycles | list | Not cyclical, only in the event of change |
| Maximum valid setpoint offset | list | +/- -5 K |
| Function Channel C6 | list | allocated to C2 blind actuator |
| Function Channel C6 | list | switch actuator |
| Comparator value | unsignedInt 1…1000 | 10 |
| Transmit counter status every | unsignedInt 1…1000 | 10 |
| After long operation | list | do not send |
| Cycle time | list | 30 min. |
| Send if input = 0 (or fault inactive) | list | yes |
| Minimum valid base setpoint value | list | 10 °C |
| Transmit counter status cyclically | list | no |
| Telegram once the Comparator value is reached | list | ON otherwise OFF |
| Telegram | list | 25% |
| Maximum valid base setpoint value | list | 32 °C |
| Function Channel C7 | list | switch actuator |
| Function Channel C7 | list | allocated to C3 blind actuator |
| Function Channel C8 | list | switch actuator |
| Function Channel C8 | list | allocated to C4 blind actuator |
| After double-click | list | do not send |
| Send collective feedback (Only switching actuator channels) | list | no |
| Telegram | list | TOGGLE |
| Telegram | list | 50% |
| Telegram | unsignedInt 0…255 | 0 |
| Send object 1 | list | no |
| Send object 2 | list | no |
| Send a second telegram? | list | no |
| Send object 3 | list | no |
| Telegram | list | 75% |
| After short operation | list | do not send |
| Send object 4 | list | no |
| Proportional band of the cooling control | list | 4 K |
| System type | list | Cooling surface |
| Integrated time of the cooling control | list | 180 min. |
| Send cooling actuating value | list | With change of 5 % |
| Send the cooling actuating value in cycles | list | Not cyclical, only in the event of change |
| Send object 1 | list | yes |
| Switchover between heating and cooling | list | automatic |
| Value | signedInt -999…999 | 50 |
| Telegram | list | 30% |
| Format object heating/cooling | list | DPT100 (Heating= 1 / Cooling=0) |
| Output of the cooling actuating value | list | On separate object |
| Telegram | unsignedInt 0…255 | 128 |
| Telegram | unsignedInt 0…255 | 50 |
| Send a third telegram? | list | no |
| Dead zone between heating and cooling | list | 2 K |
| Increase in standby mode (during cooling) | list | 1.5 K |
| Increase in night mode (during cooling) | list | 5 K |
| Setpoint value for heat protection mode (during cooling) | list | 42 °C i.e. no real heat protection |
| Value | signedInt -999…999 | 75 |
| Telegram | unsignedInt 0…255 | 75 |
| Channel function | list | Switching ON/OFF |
| Adjust dimming value limits | list | no |
| Channel function | list | shutters/blinds |
| - | list | shutters/blinds |
| Function activated by | list | Switching object |
| Adjust soft switching | list | no |
| Type of motor | list | electromechanical |
| Operating mode after reset | list | Standby |
| Drive application | list | blinds.. |
| Adjust lock function | list | no |
| Setting the drive runtime | list | via ETS |
| Type of presence sensor | list | Presence detector |
| Activate forced mode | list | no |
| Response after download | list | maintain runtime |
| Comfort extension by presence buttons in night mode | list | 2 hours |
| Activate scenes | list | no |
| Activate sun protection mode | list | no |
| Lock Comfort/Auto on UP/DOWN/STOP command (dev. from 08.2016) | list | no, only via object Comfort/Automatic |
| Format feedback height (dev. from 08.2016) | list | % |
| Participation in central objects | list | no |
| Direction of drive run | list | normal |
| Set feedback | list | no |
| Adjust feedback | list | no |
| Complete runtime Down (s) | unsignedInt 5…500 | 50 |
| Activate hour meter | list | no |
| Runtime adjustment for ascent (s) | signedInt -15…15 | 0 |
| Activate diagnostic messages | list | no |
| Send the current operating mode in cycles | list | Not cyclical, only in the event of change |
| Step duration of Step/Stop object | list | 1 s |
| Complete lamella turn (x 100 ms) | unsignedInt 4…250 | 10 |
| Tighten fabric (awnings) | list | no |
| No. of steps for a complete turn | list | 7 steps |
| Lock telegram | list | lock with 1 (standard) |
| On receipt of a step/stop command | list | process immediately (recommended) |
| 1111 Switching function | list | default value - dummy |
| 1301 Switching function | list | default value - dummy |
| Pause time before reversal of direction | list | 0.5 s |
| Activate logic link | list | no |
| Automatic execution of lamella object value (%) after the height object (%) | list | yes |
| Reaction when unlocking | list | update |
| Allocation of 0% position to slat object [%] | list | 0% corresponds to slats position on lowering |
| Participation in central UP/DOWN object | list | yes |
| Transmission of feedback | list | only at change |
| Time for cyclical transmission of feedback | list | 15 min. |
| Telegram | unsignedInt 0…255 | 100 |
| Lock telegram | list | Lock with ON telegram |
| Response when setting the lock | list | unchanged (stopped upon command) |
| Type of contact | list | NO contact |
| Load selection | list | automatic |
| Channel processes actuating value for | list | Heating |
| Response when cancelling the lock | list | update (height / lamella) |
| LED Lamps (RC) | list | default value - dummy |
| *** 10 % point in 100 µs (Standard=24) | unsignedInt 15…93 | 24 |
| *** 20 % point in 100 µs (Standard=31) | unsignedInt 15…93 | 31 |
| *** 30 % point in 100 µs (Standard=36) | unsignedInt 15…93 | 36 |
| *** 40 % point in 100 µs (Standard=41) | unsignedInt 15…93 | 41 |
| *** 50 % point in 100 µs (Standard=46) | unsignedInt 15…93 | 46 |
| *** 60 % point in 100 µs (Standard=51) | unsignedInt 15…93 | 51 |
| *** 70 % point in 100 µs (Standard=56) | unsignedInt 15…93 | 56 |
| *** 80 % point in 100 µs (Standard=63) | unsignedInt 15…93 | 63 |
| *** 90 % point in 100 µs (Standard=75) | unsignedInt 15…93 | 75 |
| *** Start-up value | list | 50 % |
| ATTENTION: USE ONLY AFTER DISCUSSING WITH HOTLINE! | list | RC mode SET PERMANENTLY! |
| *** Type of load | list | RC |
| *** Start-up time (unit) | list | 20 ms |
| Start-up time | list | 10 s |
| *** Start-up time (factor) | unsignedInt 0…127 | 50 |
| Status at download and bus failure | list | OFF |
| Status at download and bus failure | list | unchanged |
| PWM Einheit - SPÄTER UNSICHTBAR - | list | Minutes |
| *** 100 % point in 100 µs (Standard=100) | list | 100 % = limited to the 90 % setting |
| Minimum dimming value | list | 10 % |
| Status at restoration of mains or bus power | list | OFF |
| Status at restoration of mains or bus power | list | same as before failure |
| Dimming time 1 from 0% to 100% | list | 4 s |
| Actuation cycle time (PWM period) | list | 10 min. |
| Actuation cycle time (PWM period) for emergency program and forced operation | list | 10 min. |
| Priority of safety objects | list | 1. Wind 2. Rain, 3. Frost |
| Dimming time 2 from 0% to 100% | list | 8 s |
| Actuator direction of operation | list | Standard: 1 = Open valve (Theben actuator) |
| Monitor safety objects cyclically | list | no |
| Dimming time 3 from 0% to 100% | list | 12 s |
| Minimum actuating value | list | 0% |
| Participation in safety WIND | list | no |
| When receiving a switching order (1 bit) | list | soft on with dimming time 1 |
| Maximum actuating value | list | 90% |
| Source(s) | list | safety object 1 + 2 +3 (OR linked) |
| When receiving a dimming order (4 bit) | list | soft on with dimming time 1 |
| Actuating value when value violates the min./max. actuating value | list | 0 = 0%, otherwise use set actuating values |
| Start | list | top end position |
| When receiving an absolute value (8 bit) | list | soft on with dimming time 1 |
| End | list | same as before safety |
| Switch-on value | list | brightness value before previous switch-OFF |
| Take channel H1 into account for highest actuating value | list | yes |
| Participation in safety RAIN | list | no |
| Switching ON/OFF with a 4-bit dim telegram | list | yes |
| Consider Channel H1 for pump control | list | yes |
| 1301 Pulse function | list | default value - dummy |
| 1301 ON/OFF delay function | list | default value - dummy |
| 1301 Stairway light function | list | default value - dummy |
| 1301 Flashing function | list | default value - dummy |
| Desired room temperature during sun protection mode | list | 21 °C |
| Hours (0..3) | unsignedInt 0…3 | 0 |
| Response to presence in sun protection mode (presence object = 1) | list | update (height / lamella) |
| Participation in safety FROST | list | no |
| Minutes (0..60) | unsignedInt 0…60 | 0 |
| Response to heating support | list | top end position |
| Seconds (0..255) | unsignedInt 0…255 | 1 |
| Response when heating support is no longer needed | list | no reaction, unchanged |
| Pulse can be retriggered (via 1 to switching object) | list | no |
| Max. cumulated pulses 1..40 | unsignedInt 1…40 | 5 |
| Response to cooling support | list | bottom end position |
| Response after priority on safety | list | no reaction, unchanged |
| Pulse can be reset (with 0 on switching object) | list | no |
| Duration of first warning in s (0..60) | unsignedInt 0…60 | 10 |
| Response when cooling support is no longer needed | list | no reaction, unchanged |
| Duration of second warning in s (0..60) | unsignedInt 0…60 | 30 |
| Height | list | 0 % |
| Seconds (0..255) | unsignedInt 0…255 | 0 |
| Lamella | list | 100 % |
| How often should it flash | list | 3 x |
| Height | list | 40 % |
| Type of threshold value object | list | object type: percentage (dpt5.001) |
| Perform limitation when writing object | list | no |
| Lower threshold value format: (-)0,00..99999 | text | 20,0 |
| Lower threshold value (in %) | unsignedInt 1…99 | 50 |
| Threshold | unsignedInt 1…254 | 127 |
| Threshold | unsignedInt 1…65534 | 1000 |
| Limit applies to soft switching | list | no |
| Limit applies to switching command (1-bit) | list | no |
| Lower threshold value format: (-)0,00..99999 | text | 20,0 |
| Lower threshold value | unsignedInt 1…254 | 127 |
| Lower threshold value | unsignedInt 1…65534 | 1000 |
| Hysteresis format: 0,00..9999 | text | 1,0 |
| Hysteresis (in %) | unsignedInt 1…99 | 10 |
| Hysteresis | unsignedInt 1…254 | 5 |
| Hysteresis | unsignedInt 1…65534 | 5 |
| Limit applies to absolute dimming (8-bit) | list | no |
| Limit applies to relative dimming (4-bit) | list | no |
| Height | list | 50 % |
| Response at exceeding threshold | list | as switching object = 1 |
| Actuating value for emergency program is | list | Ambient temperature dependent |
| Emergency program active when outside temperature below | list | 10 °C |
| Fixed emergency program in winter mode | list | 20% |
| Height | list | 60 % |
| Max. actuating value in emergency program | list | 40% |
| Fixed emergency program with failure of outside temperature | list | 20% |
| Height | list | 70 % |
| Height | list | 80 % |
| Response when setting the lock | list | unchanged |
| Response when cancelling the lock | list | unchanged |
| Response when cancelling the lock | list | update |
| Height | list | 90 % |
| Height | list | 100 % |
| Lock telegram for scenes | list | Lock with ON telegram |
| All scene statuses of channel | list | overwrite when downloading |
| Participation in object Central scene | list | no |
| Channel reacts to | list | scene number 1 |
| Time for Soft ON | list | 1 min |
| Actuating value in the forced operation mode | list | 0% |
| Status after download | list | OFF |
| Permit teach-in | list | yes |
| Channel reacts to | list | scene number 2 |
| Dimming value after Soft ON | list | 100 % |
| Forced telegram | list | 1 = Force (standard) |
| Channel reacts to | list | scene number 3 |
| Time between Soft ON and Soft OFF | list | 5 min. |
| Response when unlocking the scene (with scene value 63) | list | no reaction |
| Channel reacts to | list | scene number 4 |
| Time for Soft OFF | list | 1 min |
| Channel reacts to | list | scene number 1 (value = 0) |
| Comment for this scene number | text | [Name] |
| Channel reacts to | list | scene number 5 |
| Lock comfort/automatic during this scene | list | no |
| Channel reacts to | list | scene number 6 |
| Cycle time | list | 5 min. |
| Object 4 type | list | switching (1-bit) |
| Channel reacts to | list | scene number 2 (value = 1) |
| Channel reacts to | list | scene number 7 |
| Channel reacts to | list | scene number 8 |
| Channel reacts to | list | scene number 3 (value = 2) |
| Reported status | list | not inverted |
| Channel reacts to | list | scene number 4 (value = 3) |
| Transmit feedback cyclically | list | no |
| Height | list | 50% |
| Channel reacts to | list | scene number 5 (value = 4) |
| Lamella | list | 25% |
| Channel reacts to | list | scene number 6 (value = 5) |
| Channel reacts to | list | scene number 7 (value = 6) |
| Type of hour meter | list | operating hours counter |
| Channel reacts to | list | scene number 8 (value = 7) |
| Service interval (0..2000, x 10 h) | unsignedInt 0…2000 | 100 |
| Response when setting the lock | list | 10 % |
| Report operating hours at change (0..100 h, 0 = no report) | unsignedInt 0…100 | 10 |
| Report time to service when changed (0..100 h, 0 = no report) | unsignedInt 0…100 | 10 |
| Transmit operating hours cyclically | list | no |
| Transmit time to service cyclically | list | no |
| Response when receiving a 1 | list | top end position |
| Response when receiving a 0 | list | no reaction |
| Report service cyclically | list | no |
| Time for cyclical transmission | list | 60 min |
| Time for cyclical transmission (time to service) | list | 60 min |
| Activate logic link | list | AND-link |
| Lock object affects link object | list | no |
| Response in the event of download and bus failure | list | no reaction |
| Response when bus or mains power restored | list | no reaction |
| Copy main parameters from channel C1 | list | no |
| - | list | no |
| Format of forced object | list | 1 bit |
| Activate forced mode with | list | 1 |
| Behaviour at start of forced mode operation | list | no change |
| Reaction on forced ON | list | no change |
| Behaviour at end of forced mode | list | value before forced mode |
| Reaction on forced OFF | list | OFF |
| Activate current metering | list | no |
| 2111 Switching function | list | default value - dummy |
| Allocated dimming value | list | 10 % |
| Response when receiving scene numbers | list | soft on with dimming time 1 |
| Allocated dimming value | list | 20 % |
| Allocated dimming value | list | 30 % |
| Allocated dimming value | list | 40 % |
| Allocated dimming value | list | 50 % |
| Allocated dimming value | list | 60 % |
| Allocated dimming value | list | 70 % |
| Allocated dimming value | list | 80 % |
| 2301 Flashing function | list | default value - dummy |
| 2301 Pulse function | list | default value - dummy |
| 2301 ON/OFF delay function | list | default value - dummy |
| 2301 Stairway light function | list | default value - dummy |
| Comment for this scene number | text | [Name eingeben] |
| Format of 1-bit feedback | list | not inverted |
| Send 1-bit feedback cyclically | list | no |
| Send 8-bit feedback | list | only after ending dimming process |
| Send 8-bit feedback cyclically | list | no |
| Time for cyclical transmission of feedback(if available) | list | 60 min |
| Status at download and bus failure | list | same as before failure |
| Take channel H2 into account for highest actuating value | list | yes |
| Take channel H2 into account for pump control | list | yes |
| Transmit current value at change | list | no |
| Transmit current value cyclically | list | no |
| Conversion of current into theoretical power | list | no |
| Conversion: Power = Current x factor (Factor = Tension x cos phi) | unsignedInt 0…255 | 0 |
| Conversion: Power = Current x factor (Factor = Tension x cos phi) | unsignedInt 1…255 | 1 |
| Transmit contact errors cyclically (current through open contact) | list | no |
| Delaying measurement after switching the contact (0..60 s) | unsignedInt 0…60 | 3 |
| Overload monitoring | list | no |
| Threshold for overload (1..200) x 100 mA | unsignedInt 1…200 | 1 |
| Hysteresis for overload (10..100 %) | unsignedInt 10…100 | 10 |
| Minimum duration for overload | list | 2 s |
| Telegram at overload | list | ON telegram |
| Telegram at no overload | list | no telegram |
| Transmit overload cyclically | list | no |
| Underload monitoring | list | no |
| Threshold value for underload (1..200) x 100 mA | unsignedInt 1…200 | 1 |
| Hysteresis for underload (10.. 100 %) | unsignedInt 10…100 | 10 |
| Minimum duration for underload | list | 2 s |
| Telegram at underload | list | ON telegram |
| Telegram at no underload | list | no telegram |
| Transmit underload cyclically | list | no |
| Time for cyclical transmission (current value,contact error, load monitoring) | list | 60 min |
| Send general error cyclically | list | no |
| Send short circuit cyclically | list | no |
| Send excess temperature cyclically | list | no |
| Send mains failure cyclically | list | no |
| Send load type cyclically | list | no |
| Send status cyclically (bit set) | list | no |
| Cycle time for all diagnostic messages (if used) | list | 60 min |
| Permit teach-in | list | no |
| *** 100 % point in 100 µs (Standard=100) | list | 100 (10 ms) |
| 2301 Switching function | list | default value - dummy |
| Take channel H3 into account for highest actuating value | list | yes |
| Take channel H3 into account for pump control | list | yes |
| Time for cyclical transmission of feedback(if available) | list | 60 min |
| Take channel H4 into account for highest actuating value | list | yes |
| Take channel H4 into account for pump control | list | yes |
| - | list | With change of 5 % |
| Function | list | push button.. |
| Entprellzeit | list | 50 ms |
| Angeschlossener Taster | list | NO contact |
| - | list | 100% |
| Maximum actuating value | list | 100% |
| Take channel H5 into account for highest actuating value | list | no |
| Take channel H5 into account for pump control | list | yes |
| Position | list | 80 % |
| Take channel H6 into account for highest actuating value | list | no |
| Take channel H6 into account for pump control | list | yes |
| Monitoring time | list | 30 min. |
| Status of monitoring | list | Report only in the event of malfunction |
| Send status in cycles | list | no |
| Cycle time | list | Every 30 min. |
| Switch pump ON only when at least (only for devices from 10.2016) | list | one input actuating value is > 0 % |
| Switch-off delay for pump | list | 10 min. |
| Send pump control in cycles | list | no, only in the event of change |
| Send highest actuating value in cycles (If continuous actuating value used) | list | no, only in the event of change |
| - | list | Link 1. HME 6 T |
| Activate valve protection | list | no |
| Transmit telegram cyclically | list | yes |
| Safety objects 1-3 | list | without cycl. monitoring |
| Auto. execution of slat object value [%] after the height [%] object | list | no |
| Permit use of push buttons on device | list | yes |
| Value | signedInt -999…999 | 100 |
| Channel function | list | switching ON/OFF.. |
| Input function | list | switch / push button.. |
| Summer mode | list | no |
| Participation in central UP/DOWN object | list | no |
| Participation in scenes | list | no |
| Valve protection | list | yes |
| React to safety: | list | no |
| Link | list | no |
| 11050 Transmit response cycl. INVISIBLE | list | no |
| Activate response at actuating value failure | list | no |
| Link | list | none |
| Activate soft dimming | list | no |
| Activate feedback | list | no |
| Load selection (R,C or L): ONLY for DME 2 S | list | automatic load detection (standard) |
| Complete slats turn 20 ... 250 [x10ms] | unsignedInt 20…250 | 100 |
| Step duration of Step/Stop object | list | 3 s |
| React to rising edge | list | yes |
| Value range for complete runtime up | list | 5..255 s |
| Runtime [x 1s] | unsignedInt 5…255 | 50 |
| Runtime [x 1s] = 256 + | unsignedInt 0…244 | 0 |
| 3 = none | unsignedInt 0…3 | 3 |
| Switching | list | ON |
| minimum brightness | list | 35 % |
| Type of value | list | percentage value |
| Actuator response | list | heated at switch-ON (theben actuator) |
| Approaching positions via the bottom position (shutter/awning) | list | approach directly |
| React to falling edge | list | yes |
| Basis for ON or OFF time delay | list | 1 min |
| Basis for staircase light time | list | 1 min |
First 500 of 594 parameters shown. Download the .knxprod for the full list.
Version history
| Application | App no | Fingerprint | First seen | Size | File |
|---|---|---|---|---|---|
| MIX 2 secure 2.1 latest | $493B | B471 | 2026-11-25 | 543 KB | Download |
| MIX 2 V1.C (1.12) 1.12 | $493A | E04E | 2026-11-25 | 3.5 MB | Download |
About this file
This is the official ETS product database for the Theben AG JMG 4 T (4930250), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.
More from Theben AG
- RMG 8 490 0 251
- JMG 4 24VDC 490 0 253
- RMG 4 S 4910204
- RMG 4 C-Last 4910206
- JMG 4 S 4910250
- RMG 8 T 4930200
- RMG 4 I 4930210
- RMG 8 S 4930220
- RMG 4 U 4930223
- JMG 4 T 24V 4930260
- RM 8 T 4940200
- RM 16 T 4940205