SMG 2 S 4910223
Theben AG · Order number 4910223 · Dimmer › SMG 2 S
MIX Serie Grundgerät, 1-10 V Dimmer
Download .knxprod Switch.,dimm.,inputs,heat.,blinds:MiX-Series V1.8 1.8 · 479 KB
Product
| Manufacturer | Theben AG |
|---|---|
| Product name | SMG 2 S |
| Order number | 4910223 |
| Product text | SMG 2 S (2 Kanal 1-10V Steuermodul) |
| Hardware | MiX-Series SMG 2 S |
| Medium | Twisted Pair |
| Bus current (mA) | 10 |
| Rail mounted | Yes |
| Width (mm) | 72 |
| Registration | Registered |
| Languages | de-DE, en-US, es-ES, fr-FR, it-IT, nl-NL |
| Catalog entry | M-0048_H-4910223-2_HP-491C-18-5DCD_CI-4910223-1 |
| Fingerprint | 5DCD |
| SHA-256 | 667effdfbc76b8e5905a8cc806d39f9de3594b5838e663c094b4874d464c0ef7 |
| First seen | 2026-11-25 |
| Markets | 59 markets |
Application program: Schalt. Dimm. Antr. Heiz. Eing.:MiX-Serie V1.8 1.8
| Application number | $491C |
|---|---|
| Version | 1.8 |
| Mask version | MV-0021 (2.1) |
| KNX Data Secure | No |
| Parameters | 1817 |
| Group objects | 813 |
Group objects (813)
| No | Name | Function | Size | DPT | Flags |
|---|---|---|---|---|---|
| 0 | GM RMG4 Kanal 1 | Schalten EIN/AUS | 1 Bit | CRWU | |
| 0 | GM DMG2S / SMG2S Kanal 1 | Schalten EIN/AUS | 1 Bit | CRWU | |
| 0 | GM BMG6 Kanal 1 | Wert senden | 1 Byte | CRTU | |
| 0 | GM BMG6 Kanal 1 | Schalten EIN/AUS | 1 Bit | CRWTU | |
| 0 | GM BMG6 Kanal 1 | Priorität | 2 Bit | CRTU | |
| 0 | GM BMG6 Kanal 1 | Temperaturwert senden | 2 Bytes | CRTU | |
| 0 | GM BMG6 Kanal 1 | Schalten EIN/AUS | 1 Bit | CRWTU | |
| 0 | GM BMG6 Kanal 1 | Wert senden | 1 Byte | CRWTU | |
| 0 | GM BMG6 Kanal 1 | Prozentwert senden | 1 Byte | CRWTU | |
| 0 | GM BMG6 Kanal 1 | Lichtszene abrufen/speichern | 1 Byte | CRTU | |
| 0 | GM BMG6 Kanal 1 | Position Höhe | 1 Byte | CRTU | |
| 0 | GM BMG6 Kanal 1 | Zählerwert senden | 2 Bytes | CRTU | |
| 0 | GM BMG6 Kanal 1 | Step / Stopp | 1 Bit | CRTU | |
| 0 | GM BMG6 Kanal 1 | 2 Byte wiederholen | 2 Bytes | CRWTU | |
| 0 | GM BMG6 Kanal 1 | 1 Byte wiederholen | 1 Byte | CRWTU | |
| 0 | GM HMG4 Kanal 1 | Stellgröße stetig | 1 Byte | CRWU | |
| 0 | GM HMG4 Kanal 1 | Stellgröße schaltend | 1 Bit | CRWU | |
| 0 | GM JMG4 S C1 | Auf / Ab | 1 Bit | CRWU | |
| 1 | GM RMG4 Kanal 1 | Sperren | 1 Bit | CRWU | |
| 1 | GM RMG4 Kanal 1 | Eingang in UND-Gatter | 1 Bit | CRWU | |
| 1 | GM RMG4 Kanal 1 | Eingang in UND-Gatter | 1 Bit | CRWU | |
| 1 | GM RMG4 Kanal 1 | Eingang 2 in ODER-Gatter | 1 Bit | CRWU | |
| 1 | GM RMG4 Kanal 1 | Sperren | 1 Bit | CRWU | |
| 1 | GM RMG4 Kanal 1 | Übersteuern | 1 Bit | CRWU | |
| 1 | GM DMG2S / SMG2S Kanal 1 | heller/dunkler | 4 Bit | CRWU | |
| 1 | GM BMG6 Kanal 1 | AUF | 1 Bit | CRTU | |
| 1 | GM BMG6 Kanal 1 | heller / dunkler | 4 Bit | CRTU | |
| 1 | GM BMG6 Kanal 1 | dunkler | 4 Bit | CRTU | |
| 1 | GM BMG6 Kanal 1 | heller | 4 Bit | CRTU | |
| 1 | GM BMG6 Kanal 1 | Position Lamelle | 1 Byte | CRTU | |
| 1 | GM BMG6 Kanal 1 | AUF / AB | 1 Bit | CRWTU | |
| 1 | GM BMG6 Kanal 1 | AB | 1 Bit | CRTU | |
| 1 | GM BMG6 Kanal 1 | Schalten EIN/AUS | 1 Bit | CRTU | |
| 1 | GM BMG6 Kanal 1 | Wert senden | 1 Byte | CRTU | |
| 1 | GM HMG4 Kanal 1 | Zwangsbetrieb | 1 Bit | CRWU | |
| 1 | GM JMG4 S C1 | Step / Stop | 1 Bit | CRWU | |
| 2 | GM RMG4 Kanal 1 | Eingang 3 in ODER-Gatter | 1 Bit | CRWU | |
| 2 | GM RMG4 Kanal 1 | Eingang 3 in ODER-Gatter | 1 Bit | CRWU | |
| 2 | GM DMG2S / SMG2S Kanal 1 | Dimmwert | 1 Byte | CWU | |
| 2 | GM BMG6 Kanal 1 | Sperren | 1 Bit | CRWU | |
| 2 | GM BMG6 Kanal 1 | Reset des Zählers | 1 Bit | CRWU | |
| 2 | GM BMG6 Kanal 1 | Zähler freigeben | 1 Bit | CRWU | |
| 2 | GM BMG6 Kanal 1 | Zähler sperren | 1 Bit | CRWU | |
| 2 | GM HMG4 Kanal 1 | Stellgrößenausfall melden | 1 Bit | CRTU | |
| 2 | GM JMG4 S C1 | % Höhe | 1 Byte | CRWU | |
| 3 | GM RMG4 Kanal 1 | Eingang 4 in ODER-Gatter | 1 Bit | CRWU | |
| 3 | GM DMG2S / SMG2S Kanal 1 | Soft-Schalten | 1 Bit | CRWU | |
| 3 | GM BMG6 Kanal 2 | Wert senden | 1 Byte | CRWTU | |
| 3 | GM BMG6 Kanal 2 | Prozentwert senden | 1 Byte | CRWTU | |
| 3 | GM BMG6 Kanal 2 | Lichtszene abrufen/speichern | 1 Byte | CRTU | |
| 3 | GM BMG6 Kanal 2 | Position Höhe | 1 Byte | CRTU | |
| 3 | GM BMG6 Kanal 2 | Schalten EIN/AUS | 1 Bit | CRWTU | |
| 3 | GM BMG6 Kanal 2 | Zählerwert senden | 2 Bytes | CRTU | |
| 3 | GM BMG6 Kanal 2 | Wert senden | 1 Byte | CRTU | |
| 3 | GM BMG6 Kanal 2 | Priorität | 2 Bit | CRTU | |
| 3 | GM BMG6 Kanal 2 | Temperaturwert senden | 2 Bytes | CRTU | |
| 3 | GM BMG6 Kanal 2 | Schalten EIN/AUS | 1 Bit | CRWTU | |
| 3 | GM BMG6 Kanal 2 | Step / Stopp | 1 Bit | CRTU | |
| 3 | GM BMG6 Kanal 2 | 2 Byte wiederholen | 2 Bytes | CRWTU | |
| 3 | GM BMG6 Kanal 2 | 1 Byte wiederholen | 1 Byte | CRWTU | |
| 3 | GM HMG4 Kanal 2 | Stellgröße stetig | 1 Byte | CRWU | |
| 3 | GM HMG4 Kanal 2 | Stellgröße schaltend | 1 Bit | CRWU | |
| 3 | GM JMG4 S C1 | % Lamelle | 1 Byte | CRWU | |
| 4 | GM JMG4 S C1 | Obj. %Höhe & %Lamelle sperren | 1 Bit | CRWU | |
| 4 | GM RMG4 Kanal 1 | Rückmeldung | 1 Bit | CRTU | |
| 4 | GM DMG2S / SMG2S Kanal 1 | Dimmwert für Zwang | 1 Byte | CRWU | |
| 4 | GM DMG2S / SMG2S Kanal 1 | Zwang = 0 | 1 Bit | CRWU | |
| 4 | GM DMG2S / SMG2S Kanal 1 | Zwang = 1 | 1 Bit | CRWU | |
| 4 | GM BMG6 Kanal 2 | heller / dunkler | 4 Bit | CRTU | |
| 4 | GM BMG6 Kanal 2 | dunkler | 4 Bit | CRTU | |
| 4 | GM BMG6 Kanal 2 | dunkler | 4 Bit | CRTU | |
| 4 | GM BMG6 Kanal 2 | heller | 4 Bit | CRTU | |
| 4 | GM BMG6 Kanal 2 | AUF | 1 Bit | CRTU | |
| 4 | GM BMG6 Kanal 2 | AUF / AB | 1 Bit | CRWTU | |
| 4 | GM BMG6 Kanal 2 | AB | 1 Bit | CRTU | |
| 4 | GM BMG6 Kanal 2 | Position Lamelle | 1 Byte | CRTU | |
| 4 | GM BMG6 Kanal 2 | Schalten EIN/AUS | 1 Bit | CRTU | |
| 4 | GM BMG6 Kanal 2 | Wert senden | 1 Byte | CRTU | |
| 4 | GM HMG4 Kanal 2 | Zwangsbetrieb | 1 Bit | CRWU | |
| 5 | GM RMG4 Kanal 2 | Schalten EIN/AUS | 1 Bit | CRWU | |
| 5 | GM BMG6 Kanal 2 | Reset des Zählers | 1 Bit | CRWU | |
| 5 | GM BMG6 Kanal 2 | Zähler freigeben | 1 Bit | CRWU | |
| 5 | GM BMG6 Kanal 2 | Zähler sperren | 1 Bit | CRWU | |
| 5 | GM BMG6 Kanal 2 | Sperren | 1 Bit | CRWU | |
| 5 | GM HMG4 Kanal 2 | Stellgrößenausfall melden | 1 Bit | CRTU | |
| 5 | GM JMG4 S C2 | Auf / Ab | 1 Bit | CRWU | |
| 5 | GM DMG2S / SMG2S Kanal 1 | Rückmeldung in % | 1 Byte | CRTU | |
| 6 | GM RMG4 Kanal 2 | Sperren | 1 Bit | CRWU | |
| 6 | GM RMG4 Kanal 2 | Eingang in UND-Gatter | 1 Bit | CRWU | |
| 6 | GM RMG4 Kanal 2 | Eingang in UND-Gatter | 1 Bit | CRWU | |
| 6 | GM RMG4 Kanal 2 | Eingang 2 in ODER-Gatter | 1 Bit | CRWU | |
| 6 | GM RMG4 Kanal 2 | Übersteuern | 1 Bit | CRWU | |
| 6 | GM DMG2S / SMG2S Kanal 1 | Rückmeldung Ein/Aus | 1 Bit | CRTU | |
| 6 | GM BMG6 Kanal 3 | Wert senden | 1 Byte | CRWTU | |
| 6 | GM BMG6 Kanal 3 | Prozentwert senden | 1 Byte | CRWTU | |
| 6 | GM BMG6 Kanal 3 | Lichtszene abrufen/speichern | 1 Byte | CRTU | |
| 6 | GM BMG6 Kanal 3 | Position Höhe | 1 Byte | CRTU | |
| 6 | GM BMG6 Kanal 3 | Schalten EIN/AUS | 1 Bit | CRWTU | |
| 6 | GM BMG6 Kanal 3 | Zählerwert senden | 2 Bytes | CRTU | |
| 6 | GM BMG6 Kanal 3 | Wert senden | 1 Byte | CRTU | |
| 6 | GM BMG6 Kanal 3 | Priorität | 2 Bit | CRTU | |
| 6 | GM BMG6 Kanal 3 | Temperaturwert senden | 2 Bytes | CRTU | |
| 6 | GM BMG6 Kanal 3 | Schalten EIN/AUS | 1 Bit | CRWTU | |
| 6 | GM BMG6 Kanal 3 | Step / Stopp | 1 Bit | CRTU | |
| 6 | GM BMG6 Kanal 3 | 2 Byte wiederholen | 2 Bytes | CRWTU | |
| 6 | GM BMG6 Kanal 3 | 1 Byte wiederholen | 1 Byte | CRWTU | |
| 6 | GM HMG4 Kanal 3 | Stellgröße stetig | 1 Byte | CRWU | |
| 6 | GM HMG4 Kanal 3 | Stellgröße schaltend | 1 Bit | CRWU | |
| 6 | GM JMG4 S C2 | Step / Stop | 1 Bit | CRWU | |
| 7 | GM RMG4 Kanal 2 | Eingang 3 in ODER-Gatter | 1 Bit | CRWU | |
| 7 | GM RMG4 Kanal 2 | Eingang 3 in ODER-Gatter | 1 Bit | CRWU | |
| 7 | GM DMG2S / SMG2S Kanal 1 | allgemeine Fehlermeldung | 1 Bit | CRTU | |
| 7 | GM BMG6 Kanal 3 | heller / dunkler | 4 Bit | CRTU | |
| 7 | GM BMG6 Kanal 3 | dunkler | 4 Bit | CRTU | |
| 7 | GM BMG6 Kanal 3 | heller | 4 Bit | CRTU | |
| 7 | GM BMG6 Kanal 3 | AUF | 1 Bit | CRTU | |
| 7 | GM BMG6 Kanal 3 | AUF / AB | 1 Bit | CRWTU | |
| 7 | GM BMG6 Kanal 3 | AB | 1 Bit | CRTU | |
| 7 | GM BMG6 Kanal 3 | Position Lamelle | 1 Byte | CRTU | |
| 7 | GM BMG6 Kanal 3 | Schalten EIN/AUS | 1 Bit | CRTU | |
| 7 | GM BMG6 Kanal 3 | Wert senden | 1 Byte | CRTU | |
| 7 | GM HMG4 Kanal 3 | Zwangsbetrieb | 1 Bit | CRWU | |
| 7 | GM JMG4 S C2 | % Höhe | 1 Byte | CRWU | |
| 8 | GM RMG4 Kanal 2 | Eingang 4 in ODER-Gatter | 1 Bit | CRWU | |
| 8 | GM DMG2S / SMG2S Kanal 1 | Meldung Übertemperatur | 1 Bit | CRTU | |
| 8 | GM DMG2S / SMG2S Kanal 1 | Meldung Kurzschluß | 1 Bit | CRTU | |
| 8 | GM DMG2S / SMG2S Kanal 1 | Meldung Lastart (R,C/L) | 1 Bit | CRTU | |
| 8 | GM DMG2S / SMG2S Kanal 1 | Meldung Bus/Handbetrieb | 1 Bit | CRTU | |
| 8 | GM DMG2S / SMG2S Kanal 1 | Meldung Lastausfall | 1 Bit | CRTU | |
| 8 | GM BMG6 Kanal 3 | Reset des Zählers | 1 Bit | CRWU | |
| 8 | GM BMG6 Kanal 3 | Zähler freigeben | 1 Bit | CRWU | |
| 8 | GM BMG6 Kanal 3 | Zähler sperren | 1 Bit | CRWU | |
| 8 | GM BMG6 Kanal 3 | Sperren | 1 Bit | CRWU | |
| 8 | GM HMG4 Kanal 3 | Stellgrößenausfall melden | 1 Bit | CRTU | |
| 8 | GM JMG4 S C2 | % Lamelle | 1 Byte | CRWU | |
| 9 | GM RMG4 Kanal 2 | Rückmeldung | 1 Bit | CRTU | |
| 9 | GM DMG2S / SMG2S Kanal 1 | Statusmeldung (Bitset) | 1 Byte | CRTU | |
| 9 | GM DMG2S / SMG2S Kanal 1 | Statusmeldung (Bitset) | 1 Byte | CRTU | |
| 9 | GM BMG6 Kanal 4 | Schalten EIN/AUS | 1 Bit | CRWTU | |
| 9 | GM BMG6 Kanal 4 | Zählerwert senden | 2 Bytes | CRTU | |
| 9 | GM BMG6 Kanal 4 | Wert senden | 1 Byte | CRTU | |
| 9 | GM BMG6 Kanal 4 | Priorität | 2 Bit | CRTU | |
| 9 | GM BMG6 Kanal 4 | Temperaturwert senden | 2 Bytes | CRTU | |
| 9 | GM BMG6 Kanal 4 | Wert senden | 1 Byte | CRWTU | |
| 9 | GM BMG6 Kanal 4 | Prozentwert senden | 1 Byte | CRWTU | |
| 9 | GM BMG6 Kanal 4 | Lichtszene abrufen/speichern | 1 Byte | CRTU | |
| 9 | GM BMG6 Kanal 4 | Position Höhe | 1 Byte | CRTU | |
| 9 | GM BMG6 Kanal 4 | Schalten EIN/AUS | 1 Bit | CRWTU | |
| 9 | GM BMG6 Kanal 4 | Step / Stopp | 1 Bit | CRTU | |
| 9 | GM BMG6 Kanal 4 | 2 Byte wiederholen | 2 Bytes | CRWTU | |
| 9 | GM BMG6 Kanal 4 | 1 Byte wiederholen | 1 Byte | CRWTU | |
| 9 | GM HMG4 Kanal 4 | Stellgröße schaltend | 1 Bit | CRWU | |
| 9 | GM HMG4 Kanal 4 | Stellgröße stetig | 1 Byte | CRWU | |
| 9 | GM JMG4 S C2 | Obj. %Höhe & %Lamelle sperren | 1 Bit | CRWU | |
| 10 | GM RMG4 Kanal 3 | Schalten EIN/AUS | 1 Bit | CRWU | |
| 10 | GM DMG2S / SMG2S Kanal 2 | Schalten EIN/AUS | 1 Bit | CRWU | |
| 10 | GM BMG6 Kanal 4 | heller / dunkler | 4 Bit | CRTU | |
| 10 | GM BMG6 Kanal 4 | dunkler | 4 Bit | CRTU | |
| 10 | GM BMG6 Kanal 4 | heller | 4 Bit | CRTU | |
| 10 | GM BMG6 Kanal 4 | AUF | 1 Bit | CRTU | |
| 10 | GM BMG6 Kanal 4 | AUF / AB | 1 Bit | CRWTU | |
| 10 | GM BMG6 Kanal 4 | AB | 1 Bit | CRTU | |
| 10 | GM BMG6 Kanal 4 | Position Lamelle | 1 Byte | CRTU | |
| 10 | GM BMG6 Kanal 4 | Schalten EIN/AUS | 1 Bit | CRTU | |
| 10 | GM BMG6 Kanal 4 | Wert senden | 1 Byte | CRTU | |
| 10 | GM HMG4 Kanal 4 | Zwangsbetrieb | 1 Bit | CRWU | |
| 10 | GM JMG4 S C3 | Auf / Ab | 1 Bit | CRWU | |
| 11 | GM RMG4 Kanal 3 | Sperren | 1 Bit | CRWU | |
| 11 | GM RMG4 Kanal 3 | Eingang in UND-Gatter | 1 Bit | CRWU | |
| 11 | GM RMG4 Kanal 3 | Eingang 2 in ODER-Gatter | 1 Bit | CRWU | |
| 11 | GM RMG4 Kanal 3 | Übersteuern | 1 Bit | CRWU | |
| 11 | GM DMG2S / SMG2S Kanal 2 | heller/dunkler | 4 Bit | CRWU | |
| 11 | GM BMG6 Kanal 4 | Sperren | 1 Bit | CRWU | |
| 11 | GM BMG6 Kanal 4 | Reset des Zählers | 1 Bit | CRWU | |
| 11 | GM BMG6 Kanal 4 | Zähler freigeben | 1 Bit | CRWU | |
| 11 | GM BMG6 Kanal 4 | Zähler sperren | 1 Bit | CRWU | |
| 11 | GM HMG4 Kanal 4 | Stellgrößenausfall melden | 1 Bit | CRTU | |
| 11 | GM JMG4 S C3 | Step / Stop | 1 Bit | CRWU | |
| 12 | GM RMG4 Kanal 3 | Eingang 3 in ODER-Gatter | 1 Bit | CRWU | |
| 12 | GM DMG2S / SMG2S Kanal 2 | Dimmwert | 1 Byte | CWU | |
| 12 | GM BMG6 Kanal 5 | Schalten EIN/AUS | 1 Bit | CRWTU | |
| 12 | GM BMG6 Kanal 5 | Zählerwert senden | 2 Bytes | CRTU | |
| 12 | GM BMG6 Kanal 5 | Wert senden | 1 Byte | CRTU | |
| 12 | GM BMG6 Kanal 5 | Priorität | 2 Bit | CRTU | |
| 12 | GM BMG6 Kanal 5 | Temperaturwert senden | 2 Bytes | CRTU | |
| 12 | GM BMG6 Kanal 5 | Wert senden | 1 Byte | CRWTU | |
| 12 | GM BMG6 Kanal 5 | Prozentwert senden | 1 Byte | CRWTU | |
| 12 | GM BMG6 Kanal 5 | Lichtszene abrufen/speichern | 1 Byte | CRTU | |
| 12 | GM BMG6 Kanal 5 | Position Höhe | 1 Byte | CRTU | |
| 12 | GM BMG6 Kanal 5 | Schalten EIN/AUS | 1 Bit | CRWTU | |
| 12 | GM BMG6 Kanal 5 | Step / Stopp | 1 Bit | CRTU | |
| 12 | GM BMG6 Kanal 5 | 2 Byte wiederholen | 2 Bytes | CRWTU | |
| 12 | GM BMG6 Kanal 5 | 1 Byte wiederholen | 1 Byte | CRWTU | |
| 12 | GM HMG4 Sommerbetrieb | Sommerbetrieb EIN/AUS | 1 Bit | CRWU | |
| 12 | GM JMG4 S C3 | % Höhe | 1 Byte | CRWU | |
| 13 | GM RMG4 Kanal 3 | Eingang 4 in ODER-Gatter | 1 Bit | CRWU | |
| 13 | GM DMG2S / SMG2S Kanal 2 | Soft-Schalten | 1 Bit | CRWU | |
| 13 | GM BMG6 Kanal 5 | heller / dunkler | 4 Bit | CRTU | |
| 13 | GM BMG6 Kanal 5 | dunkler | 4 Bit | CRTU | |
| 13 | GM BMG6 Kanal 5 | heller | 4 Bit | CRTU | |
| 13 | GM BMG6 Kanal 5 | AUF | 1 Bit | CRTU | |
| 13 | GM BMG6 Kanal 5 | AUF / AB | 1 Bit | CRWTU | |
| 13 | GM BMG6 Kanal 5 | AB | 1 Bit | CRTU | |
| 13 | GM BMG6 Kanal 5 | Position Lamelle | 1 Byte | CRTU | |
| 13 | GM BMG6 Kanal 5 | Schalten EIN/AUS | 1 Bit | CRTU | |
| 13 | GM BMG6 Kanal 5 | Wert senden | 1 Byte | CRTU | |
| 13 | GM HMG4 größte Stellgröße | größte Stellgröße HMG 4 | 1 Byte | CRTU | |
| 13 | GM JMG4 S C3 | % Lamelle | 1 Byte | CRWU | |
| 14 | GM RMG4 Kanal 3 | Rückmeldung | 1 Bit | CRTU | |
| 14 | GM DMG2S / SMG2S Kanal 2 | Zwang = 0 | 1 Bit | CRWU | |
| 14 | GM DMG2S / SMG2S Kanal 2 | Dimmwert für Zwang | 1 Byte | CRWU | |
| 14 | GM DMG2S / SMG2S Kanal 2 | Zwang = 1 | 1 Bit | CRWU | |
| 14 | GM BMG6 Kanal 5 | Sperren | 1 Bit | CRWU | |
| 14 | GM BMG6 Kanal 5 | Reset des Zählers | 1 Bit | CRWU | |
| 14 | GM BMG6 Kanal 5 | Zähler freigeben | 1 Bit | CRWU | |
| 14 | GM BMG6 Kanal 5 | Zähler sperren | 1 Bit | CRWU | |
| 14 | GM HMG4 Pumpe | Pumpe EIN/AUS | 1 Bit | CRTU | |
| 14 | GM JMG4 S C3 | Obj. %Höhe & %Lamelle sperren | 1 Bit | CRWU | |
| 15 | GM RMG4 Kanal 4 | Schalten EIN/AUS | 1 Bit | CRWU | |
| 15 | GM BMG6 Kanal 6 | Wert senden | 1 Byte | CRTU | |
| 15 | GM BMG6 Kanal 6 | Prozentwert senden | 1 Byte | CRWTU | |
| 15 | GM BMG6 Kanal 6 | Lichtszene abrufen/speichern | 1 Byte | CRTU | |
| 15 | GM BMG6 Kanal 6 | Position Höhe | 1 Byte | CRTU | |
| 15 | GM BMG6 Kanal 6 | Schalten EIN/AUS | 1 Bit | CRWTU | |
| 15 | GM BMG6 Kanal 6 | Zählerwert senden | 2 Bytes | CRTU | |
| 15 | GM BMG6 Kanal 6 | Priorität | 2 Bit | CRTU | |
| 15 | GM BMG6 Kanal 6 | Temperaturwert senden | 2 Bytes | CRTU | |
| 15 | GM BMG6 Kanal 6 | Schalten EIN/AUS | 1 Bit | CRWTU | |
| 15 | GM BMG6 Kanal 6 | Step / Stopp | 1 Bit | CRTU | |
| 15 | GM BMG6 Kanal 6 | 2 Byte wiederholen | 2 Bytes | CRWTU | |
| 15 | GM BMG6 Kanal 6 | 1 Byte wiederholen | 1 Byte | CRWTU | |
| 15 | GM JMG4 S C4 | Auf / Ab | 1 Bit | CRWU | |
| 15 | GM DMG2S / SMG2S Kanal 2 | Rückmeldung in % | 1 Byte | CRTU | |
| 16 | GM RMG4 Kanal 4 | Sperren | 1 Bit | CRWU | |
| 16 | GM RMG4 Kanal 4 | Eingang in UND-Gatter | 1 Bit | CRWU | |
| 16 | GM RMG4 Kanal 4 | Eingang in UND-Gatter M1/C4 | 1 Bit | CRWU | |
| 16 | GM RMG4 Kanal 4 | Eingang 2 in ODER-Gatter | 1 Bit | CRWU | |
| 16 | GM RMG4 Kanal 4 | Übersteuern | 1 Bit | CRWU | |
| 16 | GM DMG2S / SMG2S Kanal 2 | Rückmeldung Ein/Aus | 1 Bit | CRTU | |
| 16 | GM DMG2S / SMG2S Kanal 2 | Rückmeldung Ein/Aus | 1 Bit | CRTU | |
| 16 | GM BMG6 Kanal 6 | heller / dunkler | 4 Bit | CRTU | |
| 16 | GM BMG6 Kanal 6 | dunkler | 4 Bit | CRTU | |
| 16 | GM BMG6 Kanal 6 | heller | 4 Bit | CRTU | |
| 16 | GM BMG6 Kanal 6 | AUF | 1 Bit | CRTU | |
| 16 | GM BMG6 Kanal 6 | AUF / AB | 1 Bit | CRWTU | |
| 16 | GM BMG6 Kanal 6 | AB | 1 Bit | CRTU | |
| 16 | GM BMG6 Kanal 6 | Position Lamelle | 1 Byte | CRTU | |
| 16 | GM BMG6 Kanal 6 | Schalten EIN/AUS | 1 Bit | CRTU | |
| 16 | GM BMG6 Kanal 6 | Wert senden | 1 Byte | CRTU | |
| 16 | GM JMG4 S C4 | Step / Stop | 1 Bit | CRWU | |
| 17 | GM RMG4 Kanal 4 | Eingang 3 in ODER-Gatter | 1 Bit | CRWU | |
| 17 | GM DMG2S / SMG2S Kanal 2 | allgemeine Fehlermeldung | 1 Bit | CRTU | |
| 17 | GM BMG6 Kanal 6 | Reset des Zählers | 1 Bit | CRWU | |
| 17 | GM BMG6 Kanal 6 | Zähler freigeben | 1 Bit | CRWU | |
| 17 | GM BMG6 Kanal 6 | Zähler sperren | 1 Bit | CRWU | |
| 17 | GM BMG6 Kanal 6 | Sperren | 1 Bit | CRWU | |
| 17 | GM JMG4 S C4 | % Höhe | 1 Byte | CRWU | |
| 18 | GM RMG4 Kanal 4 | Eingang 4 in ODER-Gatter | 1 Bit | CRWU | |
| 18 | GM RMG4 Kanal 4 | Eingang 4 in ODER-Gatter M1/C4 | 1 Bit | CRWU | |
| 18 | GM DMG2S / SMG2S Kanal 2 | Meldung Bus/Handbetrieb | 1 Bit | CRTU | |
| 18 | GM DMG2S / SMG2S Kanal 2 | Meldung Lastausfall | 1 Bit | CRTU | |
| 18 | GM DMG2S / SMG2S Kanal 2 | Meldung Übertemperatur | 1 Bit | CRTU | |
| 18 | GM DMG2S / SMG2S Kanal 2 | Meldung Kurzschluß | 1 Bit | CRTU | |
| 18 | GM DMG2S / SMG2S Kanal 2 | Meldung Lastart (R,C/L) | 1 Bit | CRTU | |
| 18 | GM JMG4 S C4 | % Lamelle | 1 Byte | CRWU | |
| 19 | GM RMG4 Kanal 4 | Rückmeldung | 1 Bit | CRTU | |
| 19 | GM DMG2S / SMG2S Kanal 2 | Statusmeldung (Bitset) | 1 Byte | CRTU | |
| 19 | GM JMG4 S C4 | Obj. %Höhe & %Lamelle sperren | 1 Bit | CRWU | |
| 20 | EM1 RME4 Kanal 1 | Schalten EIN/AUS | 1 Bit | CRWU | |
| 20 | EM1 DME2S / SME2S Kanal 1 | Schalten EIN/AUS | 1 Bit | CRWU | |
| 20 | EM1 BME6 Kanal 1 | Wert senden | 1 Byte | CRWTU | |
| 20 | EM1 BME6 Kanal 1 | Prozentwert senden | 1 Byte | CRWTU | |
| 20 | EM1 BME6 Kanal 1 | Lichtszene abrufen/speichern | 1 Byte | CRTU | |
| 20 | EM1 BME6 Kanal 1 | Position Höhe | 1 Byte | CRTU | |
| 20 | EM1 BME6 Kanal 1 | Schalten EIN/AUS | 1 Bit | CRWTU | |
| 20 | EM1 BME6 Kanal 1 | Zählerwert senden | 2 Bytes | CRTU | |
| 20 | EM1 BME6 Kanal 1 | Wert senden | 1 Byte | CRTU | |
| 20 | EM1 BME6 Kanal 1 | Priorität | 2 Bit | CRTU | |
| 20 | EM1 BME6 Kanal 1 | Temperaturwert senden | 2 Bytes | CRTU | |
| 20 | EM1 BME6 Kanal 1 | Schalten EIN/AUS | 1 Bit | CRWTU | |
| 20 | EM1 BME6 Kanal 1 | Step / Stopp | 1 Bit | CRTU | |
| 20 | EM1 BME6 Kanal 1 | 2 Byte wiederholen | 2 Bytes | CRWTU | |
| 20 | EM1 BME6 Kanal 1 | 1 Byte wiederholen | 1 Byte | CRWTU | |
| 20 | EM1 HME4 Kanal 1 | Stellgröße stetig | 1 Byte | CRWU | |
| 20 | EM1 HME4 Kanal 1 | Stellgröße schaltend | 1 Bit | CRWU | |
| 20 | EM1 JME4 S C1 | Auf / Ab | 1 Bit | CRWU | |
| 21 | EM1 RME4 Kanal 1 | Sperren | 1 Bit | CRWU | |
| 21 | EM1 RME4 Kanal 1 | Eingang in UND-Gatter | 1 Bit | CRWU | |
| 21 | EM1 RME4 Kanal 1 | Eingang in UND-Gatter | 1 Bit | CRWU | |
| 21 | EM1 RME4 Kanal 1 | Eingang 2 in ODER-Gatter | 1 Bit | CRWU | |
| 21 | EM1 RME4 Kanal 1 | Übersteuern | 1 Bit | CRWU | |
| 21 | EM1 DME2S / SME2S Kanal 1 | heller/dunkler | 4 Bit | CRWU | |
| 21 | EM1 BME6 Kanal 1 | AUF | 1 Bit | CRTU | |
| 21 | EM1 BME6 Kanal 1 | AUF / AB | 1 Bit | CRWTU | |
| 21 | EM1 BME6 Kanal 1 | AB | 1 Bit | CRTU | |
| 21 | EM1 BME6 Kanal 1 | Position Lamelle | 1 Byte | CRTU | |
| 21 | EM1 BME6 Kanal 1 | heller / dunkler | 4 Bit | CRTU | |
| 21 | EM1 BME6 Kanal 1 | dunkler | 4 Bit | CRTU | |
| 21 | EM1 BME6 Kanal 1 | heller | 4 Bit | CRTU | |
| 21 | EM1 BME6 Kanal 1 | Schalten EIN/AUS | 1 Bit | CRTU | |
| 21 | EM1 BME6 Kanal 1 | Wert senden | 1 Byte | CRTU | |
| 21 | EM1 HME4 Kanal 1 | Zwangsbetrieb | 1 Bit | CRWU | |
| 21 | EM1 JME4 S C1 | Step / Stop | 1 Bit | CRWU | |
| 22 | EM1 RME4 Kanal 1 | Eingang 3 in ODER-Gatter | 1 Bit | CRWU | |
| 22 | EM1 DME2S / SME2S Kanal 1 | Dimmwert | 1 Byte | CWU | |
| 22 | EM1 BME6 Kanal 1 | Sperren | 1 Bit | CRWU | |
| 22 | EM1 BME6 Kanal 1 | Reset des Zählers | 1 Bit | CRWU | |
| 22 | EM1 BME6 Kanal 1 | Zähler freigeben | 1 Bit | CRWU | |
| 22 | EM1 BME6 Kanal 1 | Zähler sperren | 1 Bit | CRWU | |
| 22 | EM1 HME4 Kanal 1 | Stellgrößenausfall melden | 1 Bit | CRTU | |
| 22 | EM1 JME4 S C1 | % Höhe | 1 Byte | CRWU | |
| 23 | EM1 RME4 Kanal 1 | Eingang 4 in ODER-Gatter | 1 Bit | CRWU | |
| 23 | EM1 DME2S / SME2S Kanal 1 | Soft-Schalten | 1 Bit | CRWU | |
| 23 | EM1 BME6 Kanal 2 | Position Höhe | 1 Byte | CRTU | |
| 23 | EM1 BME6 Kanal 2 | Wert senden | 1 Byte | CRWTU | |
| 23 | EM1 BME6 Kanal 2 | Prozentwert senden | 1 Byte | CRWTU | |
| 23 | EM1 BME6 Kanal 2 | Lichtszene abrufen/speichern | 1 Byte | CRTU | |
| 23 | EM1 BME6 Kanal 2 | Schalten EIN/AUS | 1 Bit | CRWTU | |
| 23 | EM1 BME6 Kanal 2 | Zählerwert senden | 2 Bytes | CRTU | |
| 23 | EM1 BME6 Kanal 2 | Wert senden | 1 Byte | CRTU | |
| 23 | EM1 BME6 Kanal 2 | Priorität | 2 Bit | CRTU | |
| 23 | EM1 BME6 Kanal 2 | Temperaturwert senden | 2 Bytes | CRTU | |
| 23 | EM1 BME6 Kanal 2 | Schalten EIN/AUS | 1 Bit | CRWTU | |
| 23 | EM1 BME6 Kanal 2 | Step / Stopp | 1 Bit | CRTU | |
| 23 | EM1 BME6 Kanal 2 | 1 Byte wiederholen | 1 Byte | CRWTU | |
| 23 | EM1 BME6 Kanal 2 | 2 Byte wiederholen | 2 Bytes | CRWTU | |
| 23 | EM1 HME4 Kanal 2 | Stellgröße stetig | 1 Byte | CRWU | |
| 23 | EM1 HME4 Kanal 2 | Stellgröße schaltend | 1 Bit | CRWU | |
| 23 | EM1 JME4 S C1 | % Lamelle | 1 Byte | CRWU | |
| 24 | EM1 RME4 Kanal 1 | Rückmeldung | 1 Bit | CRTU | |
| 24 | EM1 DME2S / SME2S Kanal 1 | Dimmwert für Zwang | 1 Byte | CRWU | |
| 24 | EM1 DME2S / SME2S Kanal 1 | Zwang = 0 | 1 Bit | CRWU | |
| 24 | EM1 DME2S / SME2S Kanal 1 | Zwang = 1 | 1 Bit | CRWU | |
| 24 | EM1 BME6 Kanal 2 | AUF | 1 Bit | CRTU | |
| 24 | EM1 BME6 Kanal 2 | AUF / AB | 1 Bit | CRWTU | |
| 24 | EM1 BME6 Kanal 2 | AB | 1 Bit | CRTU | |
| 24 | EM1 BME6 Kanal 2 | Position Lamelle | 1 Byte | CRTU | |
| 24 | EM1 BME6 Kanal 2 | heller / dunkler | 4 Bit | CRTU | |
| 24 | EM1 BME6 Kanal 2 | dunkler | 4 Bit | CRTU | |
| 24 | EM1 BME6 Kanal 2 | heller | 4 Bit | CRTU | |
| 24 | EM1 BME6 Kanal 2 | Schalten EIN/AUS | 1 Bit | CRTU | |
| 24 | EM1 BME6 Kanal 2 | Wert senden | 1 Byte | CRTU | |
| 24 | EM1 HME4 Kanal 2 | Zwangsbetrieb | 1 Bit | CRWU | |
| 24 | EM1 JME4 S C1 | Obj. %Höhe & %Lamelle sperren | 1 Bit | CRWU | |
| 25 | EM1 RME4 Kanal 2 | Schalten EIN/AUS | 1 Bit | CRWU | |
| 25 | EM1 BME6 Kanal 2 | Sperren | 1 Bit | CRWU | |
| 25 | EM1 BME6 Kanal 2 | Reset des Zählers | 1 Bit | CRWU | |
| 25 | EM1 BME6 Kanal 2 | Zähler freigeben | 1 Bit | CRWU | |
| 25 | EM1 BME6 Kanal 2 | Zähler sperren | 1 Bit | CRWU | |
| 25 | EM1 HME4 Kanal 2 | Stellgrößenausfall melden | 1 Bit | CRTU | |
| 25 | EM1 JME4 S C2 | Auf / Ab | 1 Bit | CRWU | |
| 25 | EM1 DME2S / SME2S Kanal 1 | Rückmeldung in % | 1 Byte | CRTU | |
| 26 | EM1 RME4 Kanal 2 | Eingang in UND-Gatter | 1 Bit | CRWU | |
| 26 | EM1 RME4 Kanal 2 | Sperren | 1 Bit | CRWU | |
| 26 | EM1 RME4 Kanal 2 | Sperren | 1 Bit | CRWU | |
| 26 | EM1 RME4 Kanal 2 | Eingang in UND-Gatter | 1 Bit | CRWU | |
| 26 | EM1 RME4 Kanal 2 | Eingang 2 in ODER-Gatter | 1 Bit | CRWU | |
| 26 | EM1 DME2S / SME2S Kanal 1 | Rückmeldung Ein/Aus | 1 Bit | CRTU | |
| 26 | EM1 RME4 Kanal 2 | Übersteuern | 1 Bit | CRWU | |
| 26 | EM1 RME4 Kanal 2 | Übersteuern | 1 Bit | CRWU | |
| 26 | EM1 BME6 Kanal 3 | Wert senden | 1 Byte | CRWTU | |
| 26 | EM1 BME6 Kanal 3 | Prozentwert senden | 1 Byte | CRWTU | |
| 26 | EM1 BME6 Kanal 3 | Lichtszene abrufen/speichern | 1 Byte | CRTU | |
| 26 | EM1 BME6 Kanal 3 | Position Höhe | 1 Byte | CRTU | |
| 26 | EM1 BME6 Kanal 3 | Schalten EIN/AUS | 1 Bit | CRWTU | |
| 26 | EM1 BME6 Kanal 3 | Zählerwert senden | 2 Bytes | CRTU | |
| 26 | EM1 BME6 Kanal 3 | Wert senden | 1 Byte | CRTU | |
| 26 | EM1 BME6 Kanal 3 | Priorität | 2 Bit | CRTU | |
| 26 | EM1 BME6 Kanal 3 | Temperaturwert senden | 2 Bytes | CRTU | |
| 26 | EM1 BME6 Kanal 3 | Schalten EIN/AUS | 1 Bit | CRWTU | |
| 26 | EM1 BME6 Kanal 3 | Step / Stopp | 1 Bit | CRTU | |
| 26 | EM1 BME6 Kanal 3 | 2 Byte wiederholen | 2 Bytes | CRWTU | |
| 26 | EM1 BME6 Kanal 3 | 1 Byte wiederholen | 1 Byte | CRWTU | |
| 26 | EM1 HME4 Kanal 3 | Stellgröße schaltend | 1 Bit | CRWU | |
| 26 | EM1 HME4 Kanal 3 | Stellgröße stetig | 1 Byte | CRWU | |
| 26 | EM1 JME4 S C2 | Step / Stop | 1 Bit | CRWU | |
| 27 | EM1 RME4 Kanal 2 | Eingang 3 in ODER-Gatter | 1 Bit | CRWU | |
| 27 | EM1 DME2S / SME2S Kanal 1 | allgemeine Fehlermeldung | 1 Bit | CRTU | |
| 27 | EM1 BME6 Kanal 3 | heller / dunkler | 4 Bit | CRTU | |
| 27 | EM1 BME6 Kanal 3 | dunkler | 4 Bit | CRTU | |
| 27 | EM1 BME6 Kanal 3 | heller | 4 Bit | CRTU | |
| 27 | EM1 BME6 Kanal 3 | AUF | 1 Bit | CRTU | |
| 27 | EM1 BME6 Kanal 3 | AUF / AB | 1 Bit | CRWTU | |
| 27 | EM1 BME6 Kanal 3 | AB | 1 Bit | CRTU | |
| 27 | EM1 BME6 Kanal 3 | Position Lamelle | 1 Byte | CRTU | |
| 27 | EM1 BME6 Kanal 3 | Schalten EIN/AUS | 1 Bit | CRTU | |
| 27 | EM1 BME6 Kanal 3 | Wert senden | 1 Byte | CRTU | |
| 27 | EM1 BME6 Kanal 3 | Schalten EIN/AUS | 1 Bit | CRTU | |
| 27 | EM1 BME6 Kanal 3 | Wert senden | 1 Byte | CRTU | |
| 27 | EM1 HME4 Kanal 3 | Zwangsbetrieb | 1 Bit | CRWU | |
| 27 | EM1 JME4 S C2 | % Höhe | 1 Byte | CRWU | |
| 28 | EM1 RME4 Kanal 2 | Eingang 4 in ODER-Gatter | 1 Bit | CRWU | |
| 28 | EM1 DME2S / SME2S Kanal 1 | Meldung Übertemperatur | 1 Bit | CRTU | |
| 28 | EM1 DME2S / SME2S Kanal 1 | Meldung Kurzschluß | 1 Bit | CRTU | |
| 28 | EM1 DME2S / SME2S Kanal 1 | Meldung Lastart (R,C/L) | 1 Bit | CRTU | |
| 28 | EM1 DME2S / SME2S Kanal 1 | Meldung Bus/Handbetrieb | 1 Bit | CRTU | |
| 28 | EM1 DME2S / SME2S Kanal 1 | Meldung Lastausfall | 1 Bit | CRTU | |
| 28 | EM1 BME6 Kanal 3 | Reset des Zählers | 1 Bit | CRWU | |
| 28 | EM1 BME6 Kanal 3 | Zähler freigeben | 1 Bit | CRWU | |
| 28 | EM1 BME6 Kanal 3 | Zähler sperren | 1 Bit | CRWU | |
| 28 | EM1 BME6 Kanal 3 | Sperren | 1 Bit | CRWU | |
| 28 | EM1 HME4 Kanal 3 | Stellgrößenausfall melden | 1 Bit | CRTU | |
| 28 | EM1 JME4 S C2 | % Lamelle | 1 Byte | CRWU | |
| 29 | EM1 RME4 Kanal 2 | Rückmeldung | 1 Bit | CRTU | |
| 29 | EM1 DME2S / SME2S Kanal 1 | Statusmeldung (Bitset) | 1 Byte | CRTU | |
| 29 | EM1 DME2S / SME2S Kanal 1 | Statusmeldung (Bitset) | 1 Byte | CRTU | |
| 29 | EM1 BME6 Kanal 4 | Schalten EIN/AUS | 1 Bit | CRWTU | |
| 29 | EM1 BME6 Kanal 4 | Zählerwert senden | 2 Bytes | CRTU | |
| 29 | EM1 BME6 Kanal 4 | Wert senden | 1 Byte | CRTU | |
| 29 | EM1 BME6 Kanal 4 | Priorität | 2 Bit | CRTU | |
| 29 | EM1 BME6 Kanal 4 | Temperaturwert senden | 2 Bytes | CRTU | |
| 29 | EM1 BME6 Kanal 4 | Wert senden | 1 Byte | CRWTU | |
| 29 | EM1 BME6 Kanal 4 | Prozentwert senden | 1 Byte | CRWTU | |
| 29 | EM1 BME6 Kanal 4 | Lichtszene abrufen/speichern | 1 Byte | CRTU | |
| 29 | EM1 BME6 Kanal 4 | Position Höhe | 1 Byte | CRTU | |
| 29 | EM1 BME6 Kanal 4 | Schalten EIN/AUS | 1 Bit | CRWTU | |
| 29 | EM1 BME6 Kanal 4 | Step / Stopp | 1 Bit | CRTU | |
| 29 | EM1 BME6 Kanal 4 | 2 Byte wiederholen | 2 Bytes | CRWTU | |
| 29 | EM1 BME6 Kanal 4 | 1 Byte wiederholen | 1 Byte | CRWTU | |
| 29 | EM1 HME4 Kanal 4 | Stellgröße schaltend | 1 Bit | CRWU | |
| 29 | EM1 HME4 Kanal 4 | Stellgröße stetig | 1 Byte | CRWU | |
| 29 | EM1 JME4 S C2 | Obj. %Höhe & %Lamelle sperren | 1 Bit | CRWU | |
| 30 | EM1 DME2S / SME2S Kanal 2 | Schalten EIN/AUS | 1 Bit | CRWU | |
| 30 | EM1 RME4 Kanal 3 | Schalten EIN/AUS | 1 Bit | CRWU | |
| 30 | EM1 BME6 Kanal 4 | heller / dunkler | 4 Bit | CRTU | |
| 30 | EM1 BME6 Kanal 4 | dunkler | 4 Bit | CRTU | |
| 30 | EM1 BME6 Kanal 4 | heller | 4 Bit | CRTU | |
| 30 | EM1 BME6 Kanal 4 | AUF | 1 Bit | CRTU | |
| 30 | EM1 BME6 Kanal 4 | AUF / AB | 1 Bit | CRWTU | |
| 30 | EM1 BME6 Kanal 4 | AB | 1 Bit | CRTU | |
| 30 | EM1 BME6 Kanal 4 | Position Lamelle | 1 Byte | CRTU | |
| 30 | EM1 BME6 Kanal 4 | Schalten EIN/AUS | 1 Bit | CRTU | |
| 30 | EM1 BME6 Kanal 4 | Wert senden | 1 Byte | CRTU | |
| 30 | EM1 HME4 Kanal 4 | Zwangsbetrieb | 1 Bit | CRWU | |
| 30 | EM1 JME4 S C3 | Auf / Ab | 1 Bit | CRWU | |
| 31 | EM1 DME2S / SME2S Kanal 2 | heller/dunkler | 4 Bit | CRWU | |
| 31 | EM1 RME4 Kanal 3 | Sperren | 1 Bit | CRWU | |
| 31 | EM1 RME4 Kanal 3 | Eingang in UND-Gatter | 1 Bit | CRWU | |
| 31 | EM1 RME4 Kanal 3 | Eingang in UND-Gatter | 1 Bit | CRWU | |
| 31 | EM1 RME4 Kanal 3 | Eingang 2 in ODER-Gatter | 1 Bit | CRWU | |
| 31 | EM1 RME4 Kanal 3 | Übersteuern | 1 Bit | CRWU | |
| 31 | EM1 BME6 Kanal 4 | Sperren | 1 Bit | CRWU | |
| 31 | EM1 BME6 Kanal 4 | Reset des Zählers | 1 Bit | CRWU | |
| 31 | EM1 BME6 Kanal 4 | Zähler freigeben | 1 Bit | CRWU | |
| 31 | EM1 BME6 Kanal 4 | Zähler sperren | 1 Bit | CRWU | |
| 31 | EM1 HME4 Kanal 4 | Stellgrößenausfall melden | 1 Bit | CRTU | |
| 31 | EM1 JME4 S C3 | Step / Stop | 1 Bit | CRWU | |
| 32 | EM1 DME2S / SME2S Kanal 2 | Dimmwert | 1 Byte | CWU | |
| 32 | EM1 RME4 Kanal 3 | Eingang 3 in ODER-Gatter | 1 Bit | CRWU | |
| 32 | EM1 BME6 Kanal 5 | Wert senden | 1 Byte | CRWTU | |
| 32 | EM1 BME6 Kanal 5 | Prozentwert senden | 1 Byte | CRWTU | |
| 32 | EM1 BME6 Kanal 5 | Lichtszene abrufen/speichern | 1 Byte | CRTU | |
| 32 | EM1 BME6 Kanal 5 | Position Höhe | 1 Byte | CRTU | |
| 32 | EM1 BME6 Kanal 5 | Schalten EIN/AUS | 1 Bit | CRWTU | |
| 32 | EM1 BME6 Kanal 5 | Zählerwert senden | 2 Bytes | CRTU | |
| 32 | EM1 BME6 Kanal 5 | Wert senden | 1 Byte | CRTU | |
| 32 | EM1 BME6 Kanal 5 | Priorität | 2 Bit | CRTU | |
| 32 | EM1 BME6 Kanal 5 | Temperaturwert senden | 2 Bytes | CRTU | |
| 32 | EM1 BME6 Kanal 5 | Schalten EIN/AUS | 1 Bit | CRWTU | |
| 32 | EM1 BME6 Kanal 5 | Step / Stopp | 1 Bit | CRTU | |
| 32 | EM1 BME6 Kanal 5 | 2 Byte wiederholen | 2 Bytes | CRWTU | |
| 32 | EM1 BME6 Kanal 5 | 1 Byte wiederholen | 1 Byte | CRWTU | |
| 32 | EM1 HME4 Sommerbetrieb | Sommerbetrieb EIN/AUS | 1 Bit | CRWU | |
| 32 | EM1 JME4 S C3 | % Höhe | 1 Byte | CRWU | |
| 33 | EM1 DME2S / SME2S Kanal 2 | Soft-Schalten | 1 Bit | CRWU | |
| 33 | EM1 RME4 Kanal 3 | Eingang 4 in ODER-Gatter | 1 Bit | CRWU | |
| 33 | EM1 BME6 Kanal 5 | heller / dunkler | 4 Bit | CRTU | |
| 33 | EM1 BME6 Kanal 5 | dunkler | 4 Bit | CRTU | |
| 33 | EM1 BME6 Kanal 5 | heller | 4 Bit | CRTU | |
| 33 | EM1 BME6 Kanal 5 | AUF | 1 Bit | CRTU | |
| 33 | EM1 BME6 Kanal 5 | AUF / AB | 1 Bit | CRWTU | |
| 33 | EM1 BME6 Kanal 5 | AB | 1 Bit | CRTU | |
| 33 | EM1 BME6 Kanal 5 | Position Lamelle | 1 Byte | CRTU | |
| 33 | EM1 BME6 Kanal 5 | Schalten EIN/AUS | 1 Bit | CRTU | |
| 33 | EM1 BME6 Kanal 5 | Wert senden | 1 Byte | CRTU | |
| 33 | EM1 HME4 größte Stellgröße | größte Stellgröße HME 4 | 1 Byte | CRTU | |
| 33 | EM1 JME4 S C3 | % Lamelle | 1 Byte | CRWU | |
| 34 | EM1 DME2S / SME2S Kanal 2 | Zwang = 0 | 1 Bit | CRWU | |
| 34 | EM1 DME2S / SME2S Kanal 2 | Dimmwert für Zwang | 1 Byte | CRWU | |
| 34 | EM1 DME2S / SME2S Kanal 2 | Zwang = 1 | 1 Bit | CRWU | |
| 34 | EM1 RME4 Kanal 3 | Rückmeldung | 1 Bit | CRTU | |
| 34 | EM1 BME6 Kanal 5 | Reset des Zählers | 1 Bit | CRWU | |
| 34 | EM1 BME6 Kanal 5 | Zähler freigeben | 1 Bit | CRWU | |
| 34 | EM1 BME6 Kanal 5 | Zähler sperren | 1 Bit | CRWU | |
| 34 | EM1 BME6 Kanal 5 | Sperren | 1 Bit | CRWU | |
| 34 | EM1 HME4 Pumpe | Pumpe EIN/AUS | 1 Bit | CRTU | |
| 34 | EM1 JME4 S C3 | Obj. %Höhe & %Lamelle sperren | 1 Bit | CRWU | |
| 35 | EM1 RME4 Kanal 4 | Schalten EIN/AUS | 1 Bit | CRWU | |
| 35 | EM1 BME6 Kanal 6 | Schalten EIN/AUS | 1 Bit | CRWTU | |
| 35 | EM1 BME6 Kanal 6 | Zählerwert senden | 2 Bytes | CRTU | |
| 35 | EM1 BME6 Kanal 6 | Wert senden | 1 Byte | CRTU | |
| 35 | EM1 BME6 Kanal 6 | Priorität | 2 Bit | CRTU | |
| 35 | EM1 BME6 Kanal 6 | Temperaturwert senden | 2 Bytes | CRTU | |
| 35 | EM1 BME6 Kanal 6 | Wert senden | 1 Byte | CRWTU | |
| 35 | EM1 BME6 Kanal 6 | Prozentwert senden | 1 Byte | CRWTU | |
| 35 | EM1 BME6 Kanal 6 | Lichtszene abrufen/speichern | 1 Byte | CRTU | |
| 35 | EM1 BME6 Kanal 6 | Position Höhe | 1 Byte | CRTU | |
| 35 | EM1 BME6 Kanal 6 | Schalten EIN/AUS | 1 Bit | CRWTU | |
| 35 | EM1 BME6 Kanal 6 | Step / Stopp | 1 Bit | CRTU | |
| 35 | EM1 BME6 Kanal 6 | 2 Byte wiederholen | 2 Bytes | CRWTU | |
| 35 | EM1 BME6 Kanal 6 | 1 Byte wiederholen | 1 Byte | CRWTU | |
| 35 | EM1 JME4 S C4 | Auf / Ab | 1 Bit | CRWU | |
| 35 | EM1 DME2S / SME2S Kanal 2 | Rückmeldung in % | 1 Byte | CRTU | |
| 36 | EM1 DME2S / SME2S Kanal 2 | Rückmeldung Ein/Aus | 1 Bit | CRTU | |
| 36 | EM1 RME4 Kanal 4 | Eingang in UND-Gatter | 1 Bit | CRWU | |
| 36 | EM1 RME4 Kanal 4 | Übersteuern | 1 Bit | CRWU | |
| 36 | EM1 RME4 Kanal 4 | Sperren | 1 Bit | CRWU | |
| 36 | EM1 RME4 Kanal 4 | Eingang in UND-Gatter | 1 Bit | CRWU | |
| 36 | EM1 RME4 Kanal 4 | Eingang 2 in ODER-Gatter | 1 Bit | CRWU | |
| 36 | EM1 DME2S / SME2S Kanal 2 | Rückmeldung Ein/Aus | 1 Bit | CRTU | |
| 36 | EM1 BME6 Kanal 6 | Position Lamelle | 1 Byte | CRTU | |
| 36 | EM1 BME6 Kanal 6 | heller / dunkler | 4 Bit | CRTU | |
| 36 | EM1 BME6 Kanal 6 | dunkler | 4 Bit | CRTU | |
| 36 | EM1 BME6 Kanal 6 | heller | 4 Bit | CRTU | |
| 36 | EM1 BME6 Kanal 6 | AUF | 1 Bit | CRTU | |
| 36 | EM1 BME6 Kanal 6 | AUF / AB | 1 Bit | CRWTU | |
| 36 | EM1 BME6 Kanal 6 | AB | 1 Bit | CRTU | |
| 36 | EM1 BME6 Kanal 6 | Schalten EIN/AUS | 1 Bit | CRTU | |
| 36 | EM1 BME6 Kanal 6 | Wert senden | 1 Byte | CRTU | |
| 36 | EM1 JME4 S C4 | Step / Stop | 1 Bit | CRWU | |
| 37 | EM1 DME2S / SME2S Kanal 2 | allgemeine Fehlermeldung | 1 Bit | CRTU | |
| 37 | EM1 RME4 Kanal 4 | Eingang 3 in ODER-Gatter | 1 Bit | CRWU | |
| 37 | EM1 BME6 Kanal 6 | Sperren | 1 Bit | CRWU | |
| 37 | EM1 BME6 Kanal 6 | Reset des Zählers | 1 Bit | CRWU | |
| 37 | EM1 BME6 Kanal 6 | Zähler freigeben | 1 Bit | CRWU | |
| 37 | EM1 BME6 Kanal 6 | Zähler sperren | 1 Bit | CRWU | |
| 37 | EM1 JME4 S C4 | % Höhe | 1 Byte | CRWU | |
| 38 | EM1 DME2S / SME2S Kanal 2 | Meldung Kurzschluß | 1 Bit | CRTU | |
| 38 | EM1 DME2S / SME2S Kanal 2 | Meldung Lastart (R,C/L) | 1 Bit | CRTU | |
| 38 | EM1 DME2S / SME2S Kanal 2 | Meldung Bus/Handbetrieb | 1 Bit | CRTU | |
| 38 | EM1 DME2S / SME2S Kanal 2 | Meldung Lastausfall | 1 Bit | CRTU | |
| 38 | EM1 DME2S / SME2S Kanal 2 | Meldung Übertemperatur | 1 Bit | CRTU | |
| 38 | EM1 RME4 Kanal 4 | Eingang 4 in ODER-Gatter | 1 Bit | CRWU | |
| 38 | EM1 JME4 S C4 | % Lamelle | 1 Byte | CRWU | |
| 39 | EM1 DME2S / SME2S Kanal 2 | Statusmeldung (Bitset) | 1 Byte | CRTU | |
| 39 | EM1 RME4 Kanal 4 | Rückmeldung | 1 Bit | CRTU | |
| 39 | EM1 JME4 S C4 | Obj. %Höhe & %Lamelle sperren | 1 Bit | CRWU | |
| 40 | EM2 RME4 Kanal 1 | Schalten EIN/AUS | 1 Bit | CRWU | |
| 40 | EM2 DME2S / SME2S Kanal 1 | Schalten EIN/AUS | 1 Bit | CRWU | |
| 40 | EM2 BME6 Kanal 1 | Wert senden | 1 Byte | CRTU | |
| 40 | EM2 BME6 Kanal 1 | Schalten EIN/AUS | 1 Bit | CRWTU | |
| 40 | EM2 BME6 Kanal 1 | Priorität | 2 Bit | CRTU | |
| 40 | EM2 BME6 Kanal 1 | Temperaturwert senden | 2 Bytes | CRTU | |
| 40 | EM2 BME6 Kanal 1 | Wert senden | 1 Byte | CRWTU | |
| 40 | EM2 BME6 Kanal 1 | Prozentwert senden | 1 Byte | CRWTU | |
| 40 | EM2 BME6 Kanal 1 | Lichtszene abrufen/speichern | 1 Byte | CRTU | |
| 40 | EM2 BME6 Kanal 1 | Position Höhe | 1 Byte | CRTU | |
| 40 | EM2 BME6 Kanal 1 | Zählerwert senden | 2 Bytes | CRTU | |
| 40 | EM2 BME6 Kanal 1 | Schalten EIN/AUS | 1 Bit | CRWTU | |
| 40 | EM2 BME6 Kanal 1 | Step / Stopp | 1 Bit | CRTU | |
| 40 | EM2 BME6 Kanal 1 | 2 Byte wiederholen | 2 Bytes | CRWTU | |
| 40 | EM2 BME6 Kanal 1 | 1 Byte wiederholen | 1 Byte | CRWTU | |
| 40 | EM2 HME4 Kanal 1 | Stellgröße stetig | 1 Byte | CRWU | |
| 40 | EM2 HME4 Kanal 1 | Stellgröße schaltend | 1 Bit | CRWU | |
| 40 | EM2 JME4 S C1 | Auf / Ab | 1 Bit | CRWU | |
| 41 | EM2 RME4 Kanal 1 | Sperren | 1 Bit | CRWU | |
| 41 | EM2 RME4 Kanal 1 | Eingang in UND-Gatter | 1 Bit | CRWU | |
| 41 | EM2 RME4 Kanal 1 | Eingang in UND-Gatter | 1 Bit | CRWU | |
| 41 | EM2 RME4 Kanal 1 | Eingang 2 in ODER-Gatter | 1 Bit | CRWU | |
| 41 | EM2 RME4 Kanal 1 | Übersteuern | 1 Bit | CRWU | |
| 41 | EM2 DME2S / SME2S Kanal 1 | heller/dunkler | 4 Bit | CRWU | |
| 41 | EM2 RME4 Kanal 1 | Sperren | 1 Bit | CRWU | |
| 41 | EM2 BME6 Kanal 1 | heller / dunkler | 4 Bit | CRTU | |
| 41 | EM2 BME6 Kanal 1 | dunkler | 4 Bit | CRTU | |
| 41 | EM2 BME6 Kanal 1 | heller | 4 Bit | CRTU | |
| 41 | EM2 BME6 Kanal 1 | AUF | 1 Bit | CRTU | |
| 41 | EM2 BME6 Kanal 1 | AUF / AB | 1 Bit | CRWTU | |
| 41 | EM2 BME6 Kanal 1 | AB | 1 Bit | CRTU | |
| 41 | EM2 BME6 Kanal 1 | Position Lamelle | 1 Byte | CRTU | |
| 41 | EM2 BME6 Kanal 1 | Schalten EIN/AUS | 1 Bit | CRTU | |
| 41 | EM2 BME6 Kanal 1 | Wert senden | 1 Byte | CRTU | |
| 41 | EM2 HME4 Kanal 1 | Zwangsbetrieb | 1 Bit | CRWU | |
| 41 | EM2 JME4 S C1 | Step / Stop | 1 Bit | CRWU | |
| 42 | EM2 RME4 Kanal 1 | Eingang 3 in ODER-Gatter | 1 Bit | CRWU | |
| 42 | EM2 DME2S / SME2S Kanal 1 | Dimmwert | 1 Byte | CWU | |
| 42 | EM2 BME6 Kanal 1 | Reset des Zählers | 1 Bit | CRWU | |
| 42 | EM2 BME6 Kanal 1 | Zähler freigeben | 1 Bit | CRWU | |
| 42 | EM2 BME6 Kanal 1 | Zähler sperren | 1 Bit | CRWU | |
| 42 | EM2 BME6 Kanal 1 | Sperren | 1 Bit | CRWU | |
| 42 | EM2 HME4 Kanal 1 | Stellgrößenausfall melden | 1 Bit | CRTU | |
| 42 | EM2 JME4 S C1 | % Höhe | 1 Byte | CRWU | |
| 43 | EM2 RME4 Kanal 1 | Eingang 4 in ODER-Gatter | 1 Bit | CRWU | |
| 43 | EM2 DME2S / SME2S Kanal 1 | Soft-Schalten | 1 Bit | CRWU | |
| 43 | EM2 BME6 Kanal 2 | Position Höhe | 1 Byte | CRTU | |
| 43 | EM2 BME6 Kanal 2 | Wert senden | 1 Byte | CRWTU | |
| 43 | EM2 BME6 Kanal 2 | Prozentwert senden | 1 Byte | CRWTU | |
| 43 | EM2 BME6 Kanal 2 | Lichtszene abrufen/speichern | 1 Byte | CRTU | |
| 43 | EM2 BME6 Kanal 2 | Schalten EIN/AUS | 1 Bit | CRWTU | |
| 43 | EM2 BME6 Kanal 2 | Zählerwert senden | 2 Bytes | CRTU | |
| 43 | EM2 BME6 Kanal 2 | Wert senden | 1 Byte | CRTU | |
| 43 | EM2 BME6 Kanal 2 | Priorität | 2 Bit | CRTU | |
| 43 | EM2 BME6 Kanal 2 | Temperaturwert senden | 2 Bytes | CRTU | |
| 43 | EM2 BME6 Kanal 2 | Schalten EIN/AUS | 1 Bit | CRWTU | |
| 43 | EM2 BME6 Kanal 2 | Step / Stopp | 1 Bit | CRTU | |
| 43 | EM2 BME6 Kanal 2 | 1 Byte wiederholen | 1 Byte | CRWTU | |
| 43 | EM2 BME6 Kanal 2 | 2 Byte wiederholen | 2 Bytes | CRWTU | |
| 43 | EM2 HME4 Kanal 2 | Stellgröße stetig | 1 Byte | CRWU | |
| 43 | EM2 HME4 Kanal 2 | Stellgröße schaltend | 1 Bit | CRWU | |
| 43 | EM2 JME4 S C1 | % Lamelle | 1 Byte | CRWU | |
| 44 | EM2 RME4 Kanal 1 | Rückmeldung | 1 Bit | CRTU | |
| 44 | EM2 DME2S / SME2S Kanal 1 | Dimmwert für Zwang | 1 Byte | CRWU | |
| 44 | EM2 DME2S / SME2S Kanal 1 | Zwang = 0 | 1 Bit | CRWU | |
| 44 | EM2 DME2S / SME2S Kanal 1 | Zwang = 1 | 1 Bit | CRWU | |
| 44 | EM2 BME6 Kanal 2 | AUF | 1 Bit | CRTU | |
| 44 | EM2 BME6 Kanal 2 | AUF / AB | 1 Bit | CRWTU | |
| 44 | EM2 BME6 Kanal 2 | AB | 1 Bit | CRTU | |
| 44 | EM2 BME6 Kanal 2 | Position Lamelle | 1 Byte | CRTU | |
| 44 | EM2 BME6 Kanal 2 | heller / dunkler | 4 Bit | CRTU | |
| 44 | EM2 BME6 Kanal 2 | dunkler | 4 Bit | CRTU | |
| 44 | EM2 BME6 Kanal 2 | heller | 4 Bit | CRTU | |
| 44 | EM2 BME6 Kanal 2 | Schalten EIN/AUS | 1 Bit | CRTU | |
| 44 | EM2 BME6 Kanal 2 | Wert senden | 1 Byte | CRTU | |
| 44 | EM2 HME4 Kanal 2 | Zwangsbetrieb | 1 Bit | CRWU | |
| 44 | EM2 JME4 S C1 | Obj. %Höhe & %Lamelle sperren | 1 Bit | CRWU | |
| 45 | EM2 RME4 Kanal 2 | Schalten EIN/AUS | 1 Bit | CRWU | |
| 45 | EM2 BME6 Kanal 2 | Sperren | 1 Bit | CRWU | |
| 45 | EM2 BME6 Kanal 2 | Zähler sperren | 1 Bit | CRWU | |
| 45 | EM2 BME6 Kanal 2 | Reset des Zählers | 1 Bit | CRWU | |
| 45 | EM2 BME6 Kanal 2 | Zähler freigeben | 1 Bit | CRWU | |
| 45 | EM2 HME4 Kanal 2 | Stellgrößenausfall melden | 1 Bit | CRTU | |
| 45 | EM2 JME4 S C2 | Auf / Ab | 1 Bit | CRWU | |
| 45 | EM2 DME2S / SME2S Kanal 1 | Rückmeldung in % | 1 Byte | CRTU | |
| 46 | EM2 RME4 Kanal 2 | Übersteuern | 1 Bit | CRWU | |
| 46 | EM2 RME4 Kanal 2 | Sperren | 1 Bit | CRWU | |
| 46 | EM2 RME4 Kanal 2 | Sperren | 1 Bit | CRWU | |
| 46 | EM2 RME4 Kanal 2 | Eingang in UND-Gatter | 1 Bit | CRWU | |
| 46 | EM2 RME4 Kanal 2 | Eingang in UND-Gatter | 1 Bit | CRWU | |
| 46 | EM2 RME4 Kanal 2 | Eingang 2 in ODER-Gatter | 1 Bit | CRWU | |
| 46 | EM2 DME2S / SME2S Kanal 1 | Rückmeldung Ein/Aus | 1 Bit | CRTU | |
| 46 | EM2 BME6 Kanal 3 | Schalten EIN/AUS | 1 Bit | CRWTU | |
| 46 | EM2 BME6 Kanal 3 | Zählerwert senden | 2 Bytes | CRTU | |
| 46 | EM2 BME6 Kanal 3 | Wert senden | 1 Byte | CRTU | |
| 46 | EM2 BME6 Kanal 3 | Priorität | 2 Bit | CRTU | |
| 46 | EM2 BME6 Kanal 3 | Temperaturwert senden | 2 Bytes | CRTU | |
| 46 | EM2 BME6 Kanal 3 | Wert senden | 1 Byte | CRWTU | |
| 46 | EM2 BME6 Kanal 3 | Prozentwert senden | 1 Byte | CRWTU | |
| 46 | EM2 BME6 Kanal 3 | Lichtszene abrufen/speichern | 1 Byte | CRTU | |
| 46 | EM2 BME6 Kanal 3 | Position Höhe | 1 Byte | CRTU | |
| 46 | EM2 BME6 Kanal 3 | Schalten EIN/AUS | 1 Bit | CRWTU | |
| 46 | EM2 BME6 Kanal 3 | Step / Stopp | 1 Bit | CRTU | |
| 46 | EM2 BME6 Kanal 3 | 2 Byte wiederholen | 2 Bytes | CRWTU | |
| 46 | EM2 BME6 Kanal 3 | 1 Byte wiederholen | 1 Byte | CRWTU | |
| 46 | EM2 HME4 Kanal 3 | Stellgröße schaltend | 1 Bit | CRWU | |
| 46 | EM2 HME4 Kanal 3 | Stellgröße stetig | 1 Byte | CRWU | |
| 46 | EM2 JME4 S C2 | Step / Stop | 1 Bit | CRWU | |
| 47 | EM2 RME4 Kanal 2 | Eingang 3 in ODER-Gatter | 1 Bit | CRWU | |
| 47 | EM2 DME2S / SME2S Kanal 1 | allgemeine Fehlermeldung | 1 Bit | CRTU | |
| 47 | EM2 BME6 Kanal 3 | heller / dunkler | 4 Bit | CRTU | |
| 47 | EM2 BME6 Kanal 3 | dunkler | 4 Bit | CRTU | |
| 47 | EM2 BME6 Kanal 3 | heller | 4 Bit | CRTU | |
| 47 | EM2 BME6 Kanal 3 | AUF | 1 Bit | CRTU | |
| 47 | EM2 BME6 Kanal 3 | AUF / AB | 1 Bit | CRWTU | |
| 47 | EM2 BME6 Kanal 3 | AB | 1 Bit | CRTU | |
| 47 | EM2 BME6 Kanal 3 | Position Lamelle | 1 Byte | CRTU | |
| 47 | EM2 BME6 Kanal 3 | Schalten EIN/AUS | 1 Bit | CRTU | |
| 47 | EM2 BME6 Kanal 3 | Wert senden | 1 Byte | CRTU | |
| 47 | EM2 HME4 Kanal 3 | Zwangsbetrieb | 1 Bit | CRWU | |
| 47 | EM2 JME4 S C2 | % Höhe | 1 Byte | CRWU | |
| 48 | EM2 RME4 Kanal 2 | Eingang 4 in ODER-Gatter | 1 Bit | CRWU | |
| 48 | EM2 DME2S / SME2S Kanal 1 | Meldung Übertemperatur | 1 Bit | CRTU | |
| 48 | EM2 DME2S / SME2S Kanal 1 | Meldung Kurzschluß | 1 Bit | CRTU | |
| 48 | EM2 DME2S / SME2S Kanal 1 | Meldung Lastart (R,C/L) | 1 Bit | CRTU | |
| 48 | EM2 DME2S / SME2S Kanal 1 | Meldung Bus/Handbetrieb | 1 Bit | CRTU | |
| 48 | EM2 DME2S / SME2S Kanal 1 | Meldung Lastausfall | 1 Bit | CRTU | |
| 48 | EM2 BME6 Kanal 3 | Sperren | 1 Bit | CRWU | |
| 48 | EM2 BME6 Kanal 3 | Reset des Zählers | 1 Bit | CRWU | |
| 48 | EM2 BME6 Kanal 3 | Zähler freigeben | 1 Bit | CRWU | |
| 48 | EM2 BME6 Kanal 3 | Zähler sperren | 1 Bit | CRWU | |
| 48 | EM2 HME4 Kanal 3 | Stellgrößenausfall melden | 1 Bit | CRTU | |
| 48 | EM2 JME4 S C2 | % Lamelle | 1 Byte | CRWU | |
| 49 | EM2 RME4 Kanal 2 | Rückmeldung | 1 Bit | CRTU | |
| 49 | EM2 DME2S / SME2S Kanal 1 | Statusmeldung (Bitset) | 1 Byte | CRTU | |
| 49 | EM2 DME2S / SME2S Kanal 1 | Statusmeldung (Bitset) | 1 Byte | CRTU | |
| 49 | EM2 BME6 Kanal 4 | Wert senden | 1 Byte | CRWTU | |
| 49 | EM2 BME6 Kanal 4 | Prozentwert senden | 1 Byte | CRWTU | |
| 49 | EM2 BME6 Kanal 4 | Lichtszene abrufen/speichern | 1 Byte | CRTU | |
| 49 | EM2 BME6 Kanal 4 | Position Höhe | 1 Byte | CRTU | |
| 49 | EM2 BME6 Kanal 4 | Schalten EIN/AUS | 1 Bit | CRWTU | |
| 49 | EM2 BME6 Kanal 4 | Zählerwert senden | 2 Bytes | CRTU | |
| 49 | EM2 BME6 Kanal 4 | Wert senden | 1 Byte | CRTU | |
| 49 | EM2 BME6 Kanal 4 | Priorität | 2 Bit | CRTU | |
| 49 | EM2 BME6 Kanal 4 | Temperaturwert senden | 2 Bytes | CRTU | |
| 49 | EM2 BME6 Kanal 4 | Step / Stopp | 1 Bit | CRTU | |
| 49 | EM2 BME6 Kanal 4 | Schalten EIN/AUS | 1 Bit | CRWTU | |
| 49 | EM2 BME6 Kanal 4 | 2 Byte wiederholen | 2 Bytes | CRWTU | |
| 49 | EM2 BME6 Kanal 4 | 1 Byte wiederholen | 1 Byte | CRWTU | |
| 49 | EM2 HME4 Kanal 4 | Stellgröße schaltend | 1 Bit | CRWU | |
| 49 | EM2 HME4 Kanal 4 | Stellgröße stetig | 1 Byte | CRWU | |
| 49 | EM2 JME4 S C2 | Obj. %Höhe & %Lamelle sperren | 1 Bit | CRWU | |
| 50 | EM2 RME4 Kanal 3 | Schalten EIN/AUS | 1 Bit | CRWU | |
| 50 | EM2 DME2S / SME2S Kanal 2 | Schalten EIN/AUS | 1 Bit | CRWU | |
| 50 | EM2 BME6 Kanal 4 | heller / dunkler | 4 Bit | CRTU | |
| 50 | EM2 BME6 Kanal 4 | dunkler | 4 Bit | CRTU | |
| 50 | EM2 BME6 Kanal 4 | heller | 4 Bit | CRTU | |
| 50 | EM2 BME6 Kanal 4 | AUF | 1 Bit | CRTU | |
| 50 | EM2 BME6 Kanal 4 | AUF / AB | 1 Bit | CRWTU | |
| 50 | EM2 BME6 Kanal 4 | AB | 1 Bit | CRTU | |
| 50 | EM2 BME6 Kanal 4 | Position Lamelle | 1 Byte | CRTU | |
| 50 | EM2 BME6 Kanal 4 | Schalten EIN/AUS | 1 Bit | CRTU | |
| 50 | EM2 BME6 Kanal 4 | Wert senden | 1 Byte | CRTU | |
| 50 | EM2 HME4 Kanal 4 | Zwangsbetrieb | 1 Bit | CRWU | |
| 50 | EM2 JME4 S C3 | Auf / Ab | 1 Bit | CRWU | |
| 51 | EM2 RME4 Kanal 3 | Eingang in UND-Gatter | 1 Bit | CRWU | |
| 51 | EM2 RME4 Kanal 3 | Eingang 2 in ODER-Gatter | 1 Bit | CRWU | |
| 51 | EM2 RME4 Kanal 3 | Sperren | 1 Bit | CRWU | |
| 51 | EM2 RME4 Kanal 3 | Eingang in UND-Gatter | 1 Bit | CRWU | |
| 51 | EM2 RME4 Kanal 3 | Übersteuern | 1 Bit | CRWU | |
| 51 | EM2 RME4 Kanal 3 | Eingang in UND-Gatter | 1 Bit | CRWU | |
| 51 | EM2 DME2S / SME2S Kanal 2 | heller/dunkler | 4 Bit | CRWU | |
| 51 | EM2 BME6 Kanal 4 | Sperren | 1 Bit | CRWU | |
| 51 | EM2 BME6 Kanal 4 | Reset des Zählers | 1 Bit | CRWU | |
| 51 | EM2 BME6 Kanal 4 | Zähler freigeben | 1 Bit | CRWU | |
| 51 | EM2 BME6 Kanal 4 | Zähler sperren | 1 Bit | CRWU | |
| 51 | EM2 HME4 Kanal 4 | Stellgrößenausfall melden | 1 Bit | CRTU | |
| 51 | EM2 JME4 S C3 | Step / Stop | 1 Bit | CRWU | |
| 52 | EM2 RME4 Kanal 3 | Eingang 3 in ODER-Gatter | 1 Bit | CRWU | |
| 52 | EM2 DME2S / SME2S Kanal 2 | Dimmwert | 1 Byte | CWU | |
| 52 | EM2 BME6 Kanal 5 | Wert senden | 1 Byte | CRTU | |
| 52 | EM2 BME6 Kanal 5 | Schalten EIN/AUS | 1 Bit | CRWTU | |
| 52 | EM2 BME6 Kanal 5 | Priorität | 2 Bit | CRTU | |
| 52 | EM2 BME6 Kanal 5 | Temperaturwert senden | 2 Bytes | CRTU | |
| 52 | EM2 BME6 Kanal 5 | Wert senden | 1 Byte | CRWTU | |
| 52 | EM2 BME6 Kanal 5 | Prozentwert senden | 1 Byte | CRWTU | |
| 52 | EM2 BME6 Kanal 5 | Lichtszene abrufen/speichern | 1 Byte | CRTU | |
| 52 | EM2 BME6 Kanal 5 | Position Höhe | 1 Byte | CRTU | |
| 52 | EM2 BME6 Kanal 5 | Zählerwert senden | 2 Bytes | CRTU | |
| 52 | EM2 BME6 Kanal 5 | Schalten EIN/AUS | 1 Bit | CRWTU | |
| 52 | EM2 BME6 Kanal 5 | Step / Stopp | 1 Bit | CRTU | |
| 52 | EM2 BME6 Kanal 5 | 2 Byte wiederholen | 2 Bytes | CRWTU | |
| 52 | EM2 BME6 Kanal 5 | 1 Byte wiederholen | 1 Byte | CRWTU | |
| 52 | EM2 HME4 Sommerbetrieb | Sommerbetrieb EIN/AUS | 1 Bit | CRWU | |
| 52 | EM2 JME4 S C3 | % Höhe | 1 Byte | CRWU | |
| 53 | EM2 RME4 Kanal 3 | Eingang 4 in ODER-Gatter | 1 Bit | CRWU | |
| 53 | EM2 DME2S / SME2S Kanal 2 | Soft-Schalten | 1 Bit | CRWU | |
| 53 | EM2 BME6 Kanal 5 | heller / dunkler | 4 Bit | CRTU | |
| 53 | EM2 BME6 Kanal 5 | dunkler | 4 Bit | CRTU | |
| 53 | EM2 BME6 Kanal 5 | heller | 4 Bit | CRTU | |
| 53 | EM2 BME6 Kanal 5 | AUF | 1 Bit | CRTU | |
| 53 | EM2 BME6 Kanal 5 | AUF / AB | 1 Bit | CRWTU | |
| 53 | EM2 BME6 Kanal 5 | AB | 1 Bit | CRTU | |
| 53 | EM2 BME6 Kanal 5 | Position Lamelle | 1 Byte | CRTU | |
| 53 | EM2 BME6 Kanal 5 | Schalten EIN/AUS | 1 Bit | CRTU | |
| 53 | EM2 BME6 Kanal 5 | Wert senden | 1 Byte | CRTU | |
| 53 | EM2 HME4 größte Stellgröße | größte Stellgröße HME 4 | 1 Byte | CRTU | |
| 53 | EM2 JME4 S C3 | % Lamelle | 1 Byte | CRWU | |
| 54 | EM2 RME4 Kanal 3 | Rückmeldung | 1 Bit | CRTU | |
| 54 | EM2 DME2S / SME2S Kanal 2 | Zwang = 0 | 1 Bit | CRWU | |
| 54 | EM2 DME2S / SME2S Kanal 2 | Dimmwert für Zwang | 1 Byte | CRWU | |
| 54 | EM2 DME2S / SME2S Kanal 2 | Zwang = 1 | 1 Bit | CRWU | |
| 54 | EM2 BME6 Kanal 5 | Sperren | 1 Bit | CRWU | |
| 54 | EM2 BME6 Kanal 5 | Reset des Zählers | 1 Bit | CRWU | |
| 54 | EM2 BME6 Kanal 5 | Zähler freigeben | 1 Bit | CRWU | |
| 54 | EM2 BME6 Kanal 5 | Zähler sperren | 1 Bit | CRWU | |
| 54 | EM2 HME4 Pumpe | Pumpe EIN/AUS | 1 Bit | CRTU | |
| 54 | EM2 JME4 S C3 | Obj. %Höhe & %Lamelle sperren | 1 Bit | CRWU | |
| 55 | EM2 RME4 Kanal 4 | Schalten EIN/AUS | 1 Bit | CRWU | |
| 55 | EM2 BME6 Kanal 6 | Schalten EIN/AUS | 1 Bit | CRWTU | |
| 55 | EM2 BME6 Kanal 6 | Zählerwert senden | 2 Bytes | CRTU | |
| 55 | EM2 BME6 Kanal 6 | Wert senden | 1 Byte | CRTU | |
| 55 | EM2 BME6 Kanal 6 | Priorität | 2 Bit | CRTU | |
| 55 | EM2 BME6 Kanal 6 | Temperaturwert senden | 2 Bytes | CRTU | |
| 55 | EM2 BME6 Kanal 6 | Wert senden | 1 Byte | CRWTU | |
| 55 | EM2 BME6 Kanal 6 | Prozentwert senden | 1 Byte | CRWTU | |
| 55 | EM2 BME6 Kanal 6 | Lichtszene abrufen/speichern | 1 Byte | CRTU | |
| 55 | EM2 BME6 Kanal 6 | Position Höhe | 1 Byte | CRTU | |
| 55 | EM2 BME6 Kanal 6 | Schalten EIN/AUS | 1 Bit | CRWTU | |
| 55 | EM2 BME6 Kanal 6 | Step / Stopp | 1 Bit | CRTU | |
| 55 | EM2 BME6 Kanal 6 | 2 Byte wiederholen | 2 Bytes | CRWTU | |
| 55 | EM2 BME6 Kanal 6 | 1 Byte wiederholen | 1 Byte | CRWTU | |
| 55 | EM2 JME4 S C4 | Auf / Ab | 1 Bit | CRWU | |
| 55 | EM2 DME2S / SME2S Kanal 2 | Rückmeldung in % | 1 Byte | CRTU | |
| 56 | EM2 RME4 Kanal 4 | Übersteuern | 1 Bit | CRWU | |
| 56 | EM2 RME4 Kanal 4 | Eingang in UND-Gatter | 1 Bit | CRWU | |
| 56 | EM2 RME4 Kanal 4 | Sperren | 1 Bit | CRWU | |
| 56 | EM2 RME4 Kanal 4 | Eingang in UND-Gatter | 1 Bit | CRWU | |
| 56 | EM2 RME4 Kanal 4 | Eingang 2 in ODER-Gatter | 1 Bit | CRWU | |
| 56 | EM2 DME2S / SME2S Kanal 2 | Rückmeldung Ein/Aus | 1 Bit | CRTU | |
| 56 | EM2 DME2S / SME2S Kanal 2 | Rückmeldung Ein/Aus | 1 Bit | CRTU | |
| 56 | EM2 BME6 Kanal 6 | heller / dunkler | 4 Bit | CRTU | |
| 56 | EM2 BME6 Kanal 6 | dunkler | 4 Bit | CRTU | |
| 56 | EM2 BME6 Kanal 6 | heller | 4 Bit | CRTU | |
| 56 | EM2 BME6 Kanal 6 | AUF | 1 Bit | CRTU | |
| 56 | EM2 BME6 Kanal 6 | AUF / AB | 1 Bit | CRWTU | |
| 56 | EM2 BME6 Kanal 6 | AB | 1 Bit | CRTU | |
| 56 | EM2 BME6 Kanal 6 | Position Lamelle | 1 Byte | CRTU | |
| 56 | EM2 BME6 Kanal 6 | Schalten EIN/AUS | 1 Bit | CRTU | |
| 56 | EM2 BME6 Kanal 6 | Wert senden | 1 Byte | CRTU | |
| 56 | EM2 JME4 S C4 | Step / Stop | 1 Bit | CRWU | |
| 57 | EM2 RME4 Kanal 4 | Eingang 3 in ODER-Gatter | 1 Bit | CRWU | |
| 57 | EM2 DME2S / SME2S Kanal 2 | allgemeine Fehlermeldung | 1 Bit | CRTU | |
| 57 | EM2 BME6 Kanal 6 | Reset des Zählers | 1 Bit | CRWU | |
| 57 | EM2 BME6 Kanal 6 | Zähler freigeben | 1 Bit | CRWU | |
| 57 | EM2 BME6 Kanal 6 | Zähler sperren | 1 Bit | CRWU | |
| 57 | EM2 BME6 Kanal 6 | Sperren | 1 Bit | CRWU | |
| 57 | EM2 JME4 S C4 | % Höhe | 1 Byte | CRWU | |
| 58 | EM2 RME4 Kanal 4 | Eingang 4 in ODER-Gatter | 1 Bit | CRWU | |
| 58 | EM2 DME2S / SME2S Kanal 2 | Meldung Bus/Handbetrieb | 1 Bit | CRTU | |
| 58 | EM2 DME2S / SME2S Kanal 2 | Meldung Lastausfall | 1 Bit | CRTU | |
| 58 | EM2 DME2S / SME2S Kanal 2 | Meldung Übertemperatur | 1 Bit | CRTU | |
| 58 | EM2 DME2S / SME2S Kanal 2 | Meldung Kurzschluß | 1 Bit | CRTU | |
| 58 | EM2 DME2S / SME2S Kanal 2 | Meldung Lastart (R,C/L) | 1 Bit | CRTU | |
| 58 | EM2 JME4 S C4 | % Lamelle | 1 Byte | CRWU | |
| 59 | EM2 RME4 Kanal 4 | Rückmeldung | 1 Bit | CRTU | |
| 59 | EM2 DME2S / SME2S Kanal 2 | Statusmeldung (Bitset) | 1 Byte | CRTU | |
| 59 | EM2 JME4 S C4 | Obj. %Höhe & %Lamelle sperren | 1 Bit | CRWU | |
| 60 | Zentral Dauer EIN | Für RMG4S, DMG2S und SMG2S | 1 Bit | CRWTU | |
| 61 | Zentral Dauer AUS | Für RMG4S, DMG2S und SMG2S | 1 Bit | CRWTU | |
| 62 | Zentral Schalten | Für RMG4S, DMG2S und SMG2S | 1 Bit | CRWTU | |
| 63 | Szene abrufen/speichern | RMG4S, DMG2S, JMG4S und SMG2S | 1 Byte | CRWTU | |
| 64 | Zentrale Sicherheit 1 | Für JMG4 S | 1 Bit | CRWU | |
| 65 | Zentrale Sicherheit 2 | Für JMG4 S | 1 Bit | CRWU | |
| 66 | Zentrale Sicherheit 3 | Für JMG4 S | 1 Bit | CRWU | |
| 67 | Zentral Auf/Ab | Für JMG4 S | 1 Bit | CRWU |
Parameters (145)
| Parameter | Type | Default |
|---|---|---|
| Sollen Szenen unterstützt werden | list | nein, keine Szenen |
| Objekte Sicherheit 1-3 | list | ohne zykl. Überwachung |
| Zuordnung der 0% Position zu den Objekten Lamelle [%] | list | 0% entspricht der Lamellenposition bei Abfahrt |
| Automatische Ausführung des Objektwertes Lamelle [%] nach Objekt Höhe [%] | list | freigegeben |
| Bedienung der Tasten am Gerät | list | freigegeben |
| Bei Empfang eines Step/Stop-Befehls | list | sofort bearbeiten (empfohlen) |
| Pausenzeit bei Richtungsumkehr | list | 0,5 s |
| Senden der Rückmeldung für Kanal 1 | list | nur bei Änderung |
| Senden der Rückmeldung für Kanal 2 | list | nur bei Änderung |
| Senden der Rückmeldung für Kanal 3 | list | nur bei Änderung |
| Senden der Rückmeldung für Kanal 4 | list | nur bei Änderung |
| Funktion | list | Schalten Ein / Aus |
| minimale Helligkeit | list | 35% |
| Art des Behangs | list | Jalousie |
| Laufzeit komplett Auf 5 ... 500 [x 1s] | unsignedInt 5…500 | 50 |
| Laufzeit komplett Auf 5 ... 500 [x 1s] | unsignedInt 5…500 | 50 |
| Art der Stellgrösse | list | stetig |
| Kontaktart | list | Schließer |
| Komplette Lamellenwendung 40 ... 250 [x10ms] | unsignedInt 20…250 | 100 |
| Stepzahl für komplette Wendung | list | 7 Steps |
| Basis für Ein- und Ausverzögerung | list | 1 min |
| Schrittdauer Objekt Step/Stop | list | 3 s |
| Basis für Impulslänge | list | 1 min |
| Zeit für einen Stellzyklus (PWM-Periode) (für Notprogramm und Zwangsbetrieb) | list | 10 min |
| Positionen über die untere Pos. anfahren (Rollladen/Markise) | list | direkt anfahren |
| Basis für Treppenlichtzeit | list | 1 min |
| Zeit für einen Stellzyklus (PWM-Periode) | list | 10 min |
| Verhalten bei Sicherheit: Anfang / Ende | list | Sicherheit unwirksam |
| Dimmzeit von 0% auf 100% | list | 8 sec. |
| Faktor für Einschaltverzögerung 0..255 x Basis | unsignedInt 0…255 | 0 |
| Faktor für Impulslänge 1..255 x Basis | unsignedInt 1…255 | 60 |
| welche Sicherheitsobjekte wirken (ODER-verknüpft) | list | Sicherheit 1, 2 und 3 |
| Verhalten des Stellantriebes | list | beim Einschalten wird geheizt (Theben-Stellantrieb |
| Faktor für Treppenlichtzeit 1..255 x Basis | unsignedInt 1…255 | 60 |
| Teilnahme am Objekt Zentral Auf/Ab | list | ja |
| Teilnahme an Szenen | list | nein |
| Bei Empfang eines Dimmwertes/Szenen-Nr. | list | mit oben eingestellter Dimmzeit andimmen |
| Faktor für Ausschaltverzögerung 0..255 x Basis | unsignedInt 0…255 | 0 |
| Verhalten bei Bus-Ausfall | list | unverändert |
| Verhalten bei Bus- und Netz-Wiederkehr | list | unverändert |
| Sommerbetrieb und Ventilschutz | list | kein Sommerbetrieb aber Ventilschutz |
| Wieviel Impulse max. aufsummieren 1..40 | unsignedInt 1…40 | 2 |
| Einschalthelligkeit | list | Helligkeitswert vor letztem Ausschalten |
| Ein-/ Ausschalten mit 4-Bit Dimmtelegr. | list | ja |
| Verknüpfung | list | keine |
| Teilnahme an Zentral-Objekten | list | ja: an allen Zentral-Objekten |
| Stellgröße im Zwangsbetrieb | list | 0 % |
| Teilnahme an Szenen | list | ja: an den Szenen 1 - 8 |
| Notprogramm bei Netzwiederkehr und Stellgrößenausfall | list | kein Notprogramm |
| Verhalten nach Busausfall | list | keine Änderung |
| Stellgrößenausfall zyklisch senden | list | nein, nur bei Änderung |
| Senden der Rückmeldung | list | nur bei Änderung |
| Verhalten nach Bus- oder Netzspannungswiederkehr | list | wie vor Busausfall |
| minimale Stellgrösse | list | 0 % |
| maximale Stellgrösse | list | 100 % |
| Verhalten bei Busausfall | list | unverändert |
| Lastauswahl (R,C oder L) ! INFO: Bei SMG2S ohne Funktion | list | automatische Lasterkennung (Standard) |
| Stellgröße bei Unter-/Überschreiten der minimalen/maximalen Stellgröße | list | 0% bzw. 100 % |
| Verhalten bei Netzwiederkehr oder Buswiederkehr | list | wie vor Ausfall |
| Verhalten bei Netzwiederkehr oder Buswiederkehr | list | AUS |
| Zeit für Soft EIN | list | 1 Min. |
| Dimmwert nach Soft EIN | list | 100 % |
| Faktor für Impulslänge 1..255 x Basis | unsignedInt 1…255 | 4 |
| Faktor für Treppenlichtzeit 1..255 x Basis | unsignedInt 1…255 | 4 |
| Zeit zwischen Soft EIN und Soft AUS | list | 5 Min. |
| Zeit für Soft AUS | list | 1 Min. |
| Zwangsfunktion | list | keine Zwangsfunktion |
| Zwangs-Objekt: 0 = kein Zwang 01 ... 255 Zwangswert für Dimmer | list | |
| Verhalten bei Zwang Beginn | list | minimale Helligkeit |
| Verhalten bei Zwang Ende | list | Wert vor Zwang |
| Diagnose und Rückmeldungen | list | keine (Obj. Dimmwert wird nicht rückgemeldet !) |
| ! INFO für SMG2S: Kurzschluß = interner Fehler | list | |
| ! INFO für SMG2S: Lastausfall = Ausfall Leistungsteil | list | |
| ! INFO für SMG2S: RC-Last = kein Netz / Last am Relais | list | |
| Senden von Diagnose und Rückmeldung | list | nur bei Änderung |
| Funktion der Eingangs | list | Schalter / Taster |
| Entprellzeit | list | 50 ms |
| Reaktion auf lang / kurz | list | Einflächenbedienung |
| Bedienung | list | AUF |
| Art des Wertgebers | list | Prozentwertgeber |
| Zählen bei | list | fallender Flanke |
| Reaktion auf steigende Flanke | list | EIN |
| Reaktion auf fallende Flanke | list | AUS |
| Objekttyp | list | Schalten (1Bit) |
| langer Tastendruck ab | list | 300 ms |
| Prozentwert | list | 50 % |
| Wert | unsignedInt 0…255 | 21 |
| Szenennummer | list | Szene 1 |
| Höhe | list | 50 % |
| Objekttyp des Telegramms | list | Wert 0..255 (1 Byte) |
| Lamelle | list | 50 % |
| Vorteiler | unsignedInt 1…1000 | 1 |
| Objekttyp für 2. Objekt | list | Schalten (1 Bit) |
| Reaktion auf steigende Flanke | list | Priorität EIN |
| Reaktion auf steigende Flanke | list | 255 = 100 % |
| Temperaturwert bei steigender Flanke | list | 21 °C |
| Schrittweite für Dimmen | list | 100 % |
| Stoppen der Fahrtbewegung durch | list | kurze Bedienung |
| Sonderfunktion nach langem Tastendruck | list | nein |
| Speichern nach Langzeitbedienung | list | nein |
| Sonderfunktion nach Langzeitbedienung | list | nein |
| Reaktion auf fallende Flanke | list | 0 = 0 % (entspricht HVAC-Mode: Auto) |
| Reaktion auf fallende Flanke | list | Priorität inaktiv |
| Temperaturwert bei fallender Flanke | list | 16 °C |
| langer Tastendruck ab | list | 3 sec |
| Funktion des Eingangsobjekts | list | Sperren |
| Telegramm zyklisch senden | list | nein |
| Verschiebestrategie (Schrittweite 10 %, Abstand 1 sec) | list | nur absenken |
| Wert bei langem Tastendruck | unsignedInt 0…255 | 13 |
| Zählertyp | list | Ereigniszähler |
| Vergleichswert | unsignedInt 1…1000 | 100 |
| Zählerstand senden alle | unsignedInt 1…1000 | 100 |
| Zykluszeit | list | 15 Minuten |
| Telegramm wenn Vergleichswert erreicht | list | EIN sonst AUS |
| Verhalten nach Bus- oder Netzspannungswiederkehr | list | wie vor Busausfall |
| Reaktion beim Setzen der Sperre | list | Sperre ignorieren |
| Zählerstand zyklisch senden | list | nein |
| Reaktion auf Sperrtelegramm | list | Sperre ignorieren |
| Reaktion bei Aufheben der Sperre | list | keine Reaktion |
| Reaktion bei Aufheben der Sperre | list | keine |
| Reaktion nach Buswiederkehr | list | keine |
| Reaktion bei Buswiederkehr | list | keine |
| Zwangs-Objekt: 0 = keine Priorität 01 ... 255 Prioritäts(ausgangs)-Wert | list | |
| Kanal 1 bei Pumpensteuerung und größter Stellgröße berücksichtigen | list | ja |
| Kanal 1 bei Pumpensteuerung berücksichtigen | list | ja |
| Kanal 2 bei Pumpensteuerung und größter Stellgröße berücksichtigen | list | ja |
| Kanal 2 bei Pumpensteuerung berücksichtigen | list | ja |
| Kanal 3 bei Pumpensteuerung und größter Stellgröße berücksichtigen | list | ja |
| Kanal 3 bei Pumpensteuerung berücksichtigen | list | ja |
| Kanal 4 bei Pumpensteuerung und größter Stellgröße berücksichtigen | list | ja |
| Kanal 4 bei Pumpensteuerung berücksichtigen | list | ja |
| Ausschaltverzögerung für Pumpe | list | 2 min |
| Pumpensteuerung zyklisch senden | list | nein, nur bei Änderung |
| größte Stellgröße zyklisch senden (falls stetige Stellgrösse verwendet) | list | nein, nur bei Änderung |
| Lastauswahl (R,C oder L) ! INFO: Bei SME2S ohne Funktion | list | automatische Lasterkennung (Standard) |
| Ausschaltverzögerung für Pumpe | list | 10 min |
| Zwangs-Objekt: 0 = keine Priorität 01...255 Prioritäts(ausgangs)-Wert | list | |
| Basis für Ein- und Ausverzögerung | list | 1 sec |
| Basis für Impulslänge | list | 1 sec |
| Basis für Treppenlichtzeit | list | 1 sec |
| Art des Grundmoduls (GM) | list | Gerät auswählen.. |
| Anzahl der Erweiterungs-Module | list | keine Erweiterung |
| Typ des 1. Erweiterungs-Moduls EM1 | list | EM1 ist ein RME4 S od. RME4 C-Last |
| Typ der 2. Erweiterungs-Moduls EM2 | list | EM2 ist ein RME4 S od. RME4 C-Last |
| Zeit für zyklisches Senden der Rückmeldeobjekte (falls verwendet) | list | 15 Minuten |
Version history
| Application | App no | Fingerprint | First seen | Size | File |
|---|---|---|---|---|---|
| Switch.,dimm.,inputs,heat.,blinds:MiX-Series V1.8 1.8 latest | $491C | 5DCD | 2026-11-25 | 479 KB | Download |
About this file
This is the official ETS product database for the Theben AG SMG 2 S (4910223), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.