MOT-Ix.02S KNX Motivity Ceiling, Secure MOT-Ix.02S
Tense · Order number MOT-Ix.02S · Motion Detectors › Motivity
Download .knxprod Motivity, Secure 1.0 · 189 KB
Product
| Manufacturer | Tense |
|---|---|
| Product name | MOT-Ix.02S KNX Motivity Ceiling, Secure |
| Order number | MOT-Ix.02S |
| Hardware | Motivity |
| Medium | Twisted Pair |
| Bus current (mA) | 5 |
| Rail mounted | No |
| Registration | Registered · 2025-10-03 |
| Languages | de-DE, en-US, es-ES, fr-FR, it-IT |
| Catalog entry | M-011F_H-648-1-O0083_HP-0694-10-F07A-O0083_CI-MOT.2DIx.2E02S-1 |
| Fingerprint | F07A |
| SHA-256 | f78df939632132c36cb9027c71b90d5c10c866646ccdecac682eca3c7af84d70 |
| First seen | 2026-11-25 |
| Markets | 67 markets |
Application program: Motivity, Secure 1.0
| Application number | $0694 |
|---|---|
| Version | 1.0 |
| Mask version | MV-07B0 (System B) |
| KNX Data Secure | Yes |
| Minimum ETS version | 5.0 |
| Parameters | 334 |
| Group objects | 84 |
Group objects (84)
| No | Name | Function | Size | DPT | Flags |
|---|---|---|---|---|---|
| 1 | In operation | Output | 1 Bit | 1.11 state | CRT |
| 2 | Day/Night | Day = 1 / Night = 0 | 1 Bit | 1.2 boolean | CWTUI |
| 2 | Day/Night | Night = 1 / Day = 0 | 1 Bit | 1.2 boolean | CWTUI |
| 3 | Scene | Input | 1 Byte | 17.1 scene number | CW |
| 4 | Light channel 1 - Output 1 | Switch | 1 Bit | 1.1 switch | CRT |
| 4 | Light channel 1 - Output 1 (day) | Switch | 1 Bit | 1.1 switch | CRT |
| 4 | Light channel 1 - Output 1 | Dimming absolute | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 4 | Light channel 1 - Output 1 | Scene | 1 Byte | 17.1 scene number | CRT |
| 5 | Light channel 1 - Output (Night) | Switch | 1 Bit | 1.1 switch | CRT |
| 6 | Light channel 1 - Output 2 (additional) | Switch | 1 Bit | 1.1 switch | CRT |
| 7 | Light channel 1 - Input | External button short | 1 Bit | 1.1 switch | CW |
| 8 | Light channel 1 - Input | External button long | 1 Bit | 1.1 switch | CW |
| 9 | Light channel 1 - Input | External motion (Slave) | 1 Bit | 1.1 switch | CW |
| 10 | Light channel 1 - Input | Status of actuator channel | 1 Bit | 1.1 switch | CW |
| 11 | Light channel 1 - Input | Lock motion detection | 1 Bit | 1.3 enable | CW |
| 12 | Light channel 1 - Input | Forced guidance | 2 Bit | 2.1 switch control | CW |
| 12 | Light channel 1 - Input | Lock object | 1 Bit | 1.3 enable | CW |
| 13 | Light channel 1 - Input | Lock object On | 1 Bit | 1.3 enable | CW |
| 14 | Light channel 1 - Status | Automatic mode | 1 Bit | 1.11 state | CRT |
| 14 | Light channel 1 - Status | Lock/Manual mode | 1 Bit | 1.11 state | CRT |
| 15 | Light channel 1 - Input | Switch dark | 1 Bit | 1.1 switch | CW |
| 16 | Light channel 1 - Input | Teach-in dimming value for ON | 1 Byte | 5.1 percentage (0..100%) | CWTUI |
| 17 | Light channel 1 - Input | Follow-up time 10 - 65000 s | 2 Bytes | 7.5 time (s) | CWTUI |
| 19 | HVAC - Output 1 | Switch | 1 Bit | 1.1 switch | CRT |
| 19 | Output - climate (HCV) | Dimming absolute | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 19 | Output - climate (HCV) | Scene | 1 Byte | 17.1 scene number | CRT |
| 22 | HVAC- Input | External button short | 1 Bit | 1.1 switch | CW |
| 23 | HVAC - Input | External button long | 1 Bit | 1.1 switch | CW |
| 24 | HVAC - Input | External motion | 1 Bit | 1.1 switch | CW |
| 25 | HVAC - Input | Status of actuator channel | 1 Bit | 1.1 switch | CW |
| 26 | HVAC - Input | Lock motion detection | 1 Bit | 1.3 enable | CW |
| 27 | HVAC - Input | Forced guidance | 2 Bit | 2.1 switch control | CW |
| 27 | HVAC - Input | Lock object | 1 Bit | 1.3 enable | CW |
| 28 | HVAC - Input | Lock object On | 1 Bit | 1.3 enable | CW |
| 29 | HVAC - Status | Automatic mode | 1 Bit | 1.11 state | CRT |
| 29 | HVAC - Status | Lock/Manual mode | 1 Bit | 1.11 state | CRT |
| 30 | HVAC - Input | Switch dark | 1 Bit | 1.1 switch | CW |
| 31 | HVAC - Input | Teach-in dimming value for ON | 1 Byte | 5.1 percentage (0..100%) | CWTUI |
| 32 | HVAC - Input | Follow-up time 10 - 65000 s | 2 Bytes | 7.5 time (s) | CWTUI |
| 34 | Alarm - Output | Switch | 1 Bit | 1.1 switch | CRT |
| 34 | Alarm - Output (Day) | Switch | 1 Bit | 1.1 switch | CRT |
| 35 | Alarm - Output (Night) | Switch | 1 Bit | 1.1 switch | CRT |
| 42 | Alarm - Input | Lock | 1 Bit | 1.3 enable | CW |
| 42 | Alarm - Input | Release | 1 Bit | 1.3 enable | CW |
| 49 | Temperature | Measured value | 2 Bytes | 9.1 temperature (°C) | CRT |
| 50 | Brightness | Threshold switch | 1 Bit | 1.1 switch | CRT |
| 51 | Brightness | Measured value | 2 Bytes | 9.4 lux (Lux) | CRT |
| 52 | Brightness | Set switch-on threshold for light channels | 2 Bytes | 9.4 lux (Lux) | CW |
| 53 | Logic 1 {{0}} | Input C | 1 Bit | 1.2 boolean | CWTU |
| 54 | Logic 1 {{0}} | Input D | 1 Bit | 1.2 boolean | CWTU |
| 55 | Logic 1 {{0}} | Input E | 1 Bit | 1.2 boolean | CWTU |
| 56 | Logic 1 {{0}} | Input F | 1 Bit | 1.2 boolean | CWTU |
| 57 | Logic 1 {{0}} | Output 1 | 1 Bit | 1.2 boolean | CRT |
| 57 | Logic 1 {{0}} | Output 1 | 1 Byte | 17.1 scene number | CRT |
| 57 | Logic 1 {{0}} | Output 1 | 1 Byte | 5.5 ratio (0..255) | CRT |
| 57 | Logic 1 {{0}} | Output 1 | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 57 | Logic 1 {{0}} | Output 1 | 2 Bit | 2.1 switch control | CRT |
| 58 | Logic 2 {{0}} | Input C | 1 Bit | 1.2 boolean | CWTU |
| 59 | Logic 2 {{0}} | Input D | 1 Bit | 1.2 boolean | CWTU |
| 60 | Logic 2 {{0}} | Input E | 1 Bit | 1.2 boolean | CWTU |
| 61 | Logic 2 {{0}} | Input F | 1 Bit | 1.2 boolean | CWTU |
| 62 | Logic 2 {{0}} | Output 2 | 1 Bit | 1.2 boolean | CRT |
| 62 | Logic 2 {{0}} | Output 2 | 1 Byte | 17.1 scene number | CRT |
| 62 | Logic 2 {{0}} | Output 2 | 1 Byte | 5.5 ratio (0..255) | CRT |
| 62 | Logic 2 {{0}} | Output 2 | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 62 | Logic 2 {{0}} | Output 2 | 2 Bit | 2.1 switch control | CRT |
| 63 | Logic 3 {{0}} | Input C | 1 Bit | 1.2 boolean | CWTU |
| 64 | Logic 3 {{0}} | Input D | 1 Bit | 1.2 boolean | CWTU |
| 65 | Logic 3 {{0}} | Input E | 1 Bit | 1.2 boolean | CWTU |
| 66 | Logic 3 {{0}} | Input F | 1 Bit | 1.2 boolean | CWTU |
| 67 | Logic 3 {{0}} | Output 3 | 1 Bit | 1.2 boolean | CRT |
| 67 | Logic 3 {{0}} | Output 3 | 1 Byte | 17.1 scene number | CRT |
| 67 | Logic 3 {{0}} | Output 3 | 1 Byte | 5.5 ratio (0..255) | CRT |
| 67 | Logic 3 {{0}} | Output 3 | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 67 | Logic 3 {{0}} | Output 3 | 2 Bit | 2.1 switch control | CRT |
| 68 | Logic 4 {{0}} | Input C | 1 Bit | 1.2 boolean | CWTU |
| 69 | Logic 4 {{0}} | Input D | 1 Bit | 1.2 boolean | CWTU |
| 70 | Logic 4 {{0}} | Input E | 1 Bit | 1.2 boolean | CWTU |
| 71 | Logic 4 {{0}} | Input F | 1 Bit | 1.2 boolean | CWTU |
| 72 | Logic 4 {{0}} | Output 4 | 1 Bit | 1.2 boolean | CRT |
| 72 | Logic 4 {{0}} | Output 4 | 1 Byte | 17.1 scene number | CRT |
| 72 | Logic 4 {{0}} | Output 4 | 1 Byte | 5.5 ratio (0..255) | CRT |
| 72 | Logic 4 {{0}} | Output 4 | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 72 | Logic 4 {{0}} | Output 4 | 2 Bit | 2.1 switch control | CRT |
Parameters (167)
| Parameter | Type | Default |
|---|---|---|
| Send "In operation" cyclically | list | not active |
| Day/Night object | list | request after reset |
| Value for Day/Night | list | Day = 1 / Night = 0 |
| Toggle Day/Night | list | at next presence |
| Switch-on threshold | unsignedInt 5…1000 | 400 |
| Switch-on threshold "Day" | unsignedInt 5…1000 | 400 |
| Switch-on threshold "Night" | unsignedInt 5…1000 | 400 |
| Switch-off if exceedance | list | not active |
| Switch-off when exceeding … | unsignedInt 75…1000 | 800 |
| Fallback of forced guidance/lock | list | not active |
| Follow-up time for forced guidance/lock | list | 3 min |
| Follow-up time for forced guidance/lock "Day" | list | 3 min |
| Follow-up time for forced guidance/lock "Night" | list | 3 min |
| Fallback time for forced guidance/lock | list | 3 min |
| Fallback time for forced guidance/lock "Day" | list | 3 min |
| Fallback time for forced guidance/lock "Night" | list | 3 min |
| Fallback for external button long (Manual => Auto) | list | after presence and follow-up time |
| Manual mode, follow-up time for ON | list | 3 min |
| Manual mode, follow-up time for OFF | list | 3 min |
| Manual mode, follow-up time for ON "Day" | list | 3 min |
| Manual mode, follow-up time for OFF "Day" | list | 3 min |
| Manual mode, follow-up time for ON "Night" | list | 3 min |
| Manual mode, follow-up time for OFF "Night" | list | 3 min |
| Manual mode, fallback time for ON | list | 3 min |
| Manual mode, fallback time for OFF | list | 3 min |
| Manual mode, fallback time for ON "Day" | list | 3 min |
| Manual mode, fallback time for OFF "Day" | list | 3 min |
| Manual mode, fallback time for ON "Night" | list | 3 min |
| Manual mode, fallback time for OFF "Night" | list | 3 min |
| Scene A number | list | not active |
| Light channel 1 | list | active |
| Scene A Light channel 1 | list | not active |
| Scene B number | list | not active |
| Scene B Light channel 1 | list | not active |
| Scene C number | list | not active |
| Scene C Light channel 1 | list | not active |
| Scene D number | list | not active |
| Scene D Light channel 1 | list | not active |
| Scene E number | list | not active |
| Scene E Light channel 1 | list | not active |
| Scene F number | list | not active |
| Scene F Light channel 1 | list | not active |
| Scene G number | list | not active |
| Scene G Light channel 1 | list | not active |
| Scene H number | list | not active |
| Scene H Light channel 1 | list | not active |
| Light channels influence the brightness measurement | list | yes (several lights in the room) |
| Send brightness on change of | list | 10 % |
| Send measured value cyclically | list | not active |
| Correction value | list | 0 % |
| Room reflection factor | list | 0.4 medium |
| Threshold switch | list | not active |
| Threshold switch switches at | unsignedInt 5…1000 | 300 |
| Hysteresis of threshold switch | unsignedInt 5…200 | 30 |
| Object value when exceeded | list | ON |
| Object value at "Day" and exceedance | list | ON |
| Object value at "Night" and exceedance | list | ON |
| Object value at lower deviation | list | OFF |
| Send | list | ON and OFF |
| Send at "Day" | list | ON and OFF |
| Send at "Night" | list | ON and OFF |
| Lux value for Teach-in | unsignedInt 200…1000 | 450 |
| Teach-in value at loading of application | list | use default value |
| Temperature measurement | list | not active |
| Send measured value on change of | list | 0.2 K |
| Correction value for sensor | signedInt -80…50 | 0 |
| HVAC | list | not active |
| Alarm/Message channel | list | not active |
| Brightness | list | basic setting or object "Switch dark" is active |
| Channel mode | list | fully automatic |
| Motion filter in standby | list | not active, no filtering |
| Reduction of follow-up time | list | not active |
| Maximum duration for short time presence | list | 20 s |
| Follow-up time for short time presence | list | 30 s |
| Follow-up time | list | 3 min |
| Follow-up time "Day" | list | 3 min |
| Follow-up time "Night" | list | 30 s |
| Forced guidance or lock object | list | forced guidance object (2 Bit) |
| Action on locking | list | lock motion (lock current state) |
| Action on unlocking | list | not active |
| Fallback of forced guidance/lock (General setting) | list | active |
| Object type for output - Light | list | Switch |
| Output objects for Day/Night | list | one common object |
| Dimming value for ON | list | 100 % |
| Dimming value for OFF | list | 0 % |
| Dimming value for "Day" when ON | list | 100 % |
| Dimming value for “Day” when OFF | list | 0 % |
| Dimming value for “Night” when ON | list | 30 % |
| Dimming value for “Night” when OFF | list | 0 % |
| Orientation light for leaving | list | switch-off immediately |
| Switch-off delay | list | 30 s |
| Switch-off dimming value | list | 30 % |
| Switch-off delay for "Day" | list | 30 s |
| Switch-off dimming value for "Day" | list | 30 % |
| Switch-off delay for "Night" | list | 30 s |
| Switch-off dimming value for "Night" | list | 20 % |
| Scene number for ON | list | 1 |
| Scene number for OFF | list | 2 |
| Scene number for "Day" when ON | list | 1 |
| Scene number for "Day" when OFF | list | 2 |
| Scene number for "Night" when ON | list | 3 |
| Scene number for "Night" when OFF | list | 4 |
| Output object 1 sends | list | ON and OFF |
| Output object 1 sends ON cyclically | list | not active |
| Output object 1 sends | list | dimming value for ON and OFF |
| Output object 1 sends value for ON cyclically | list | not active |
| Output object 1 sends | list | scene number for ON and OFF |
| Output object 1 sends scene for ON cyclically | list | not active |
| Output 2 (Additional switch object) | list | not active |
| External button short reacts to | list | ON and OFF |
| Idle time after external button short is off | unsignedInt 1…30 | 5 |
| External button long reacts to | list | ON and OFF |
| Idle time after switch off | unsignedInt 0…60 | 1 |
| If Night light is active | list | switch to Day light |
| If output "Day" is already ON | list | switch to manual mode |
| If output is already ON | list | switch to manual mode |
| Status information | list | not active |
| Number of monitoring time slots | list | 3 |
| Length of monitoring time slot | unsignedInt 0…30000 | 30 |
| Object type for output - climate (HVAC) | list | Switch |
| Object value for ON | list | value "1" |
| Object value for OFF | list | value "0" |
| Object value for “Day” when ON | list | value "1" |
| Object value for “Day” when OFF | list | value "0" |
| Object value for “Night” when ON | list | value "1" |
| Object value for “Night” when OFF | list | value "0" |
| Scene number for “Night” when ON | list | 3 |
| Scene number for “Night” when OFF | list | 4 |
| Output object 1 sends cyclically | list | not active |
| Output object 1 sends value cyclically | list | not active |
| Output object 1 sends scene cyclically | list | not active |
| Idle time after external button short is OFF | unsignedInt 1…30 | 5 |
| Interference / motion filter | list | not active, no filtering |
| Length of monitoring time slot | list | 2 s |
| Number of monitoring time slot | list | 3 |
| Lock or release object | list | lock object |
| Fallback of forced guidance/lock (General setting) | list | not active |
| Output object sends at | list | ON and OFF |
| Output object sends cyclic | list | not active |
| Logic function 1 | list | not active |
| Description of function | text | |
| Additional text | text | |
| Function | list | AND |
| Output object | list | Switch |
| Sending condition | list | on change of output |
| Output | list | normal |
| Scene number for output value "False" | list | 1 |
| Scene number for output value "True" | list | 1 |
| Value type | list | 1 Byte DPT 5.005 Decimal factor (0...255) |
| Value for output value "False" | unsignedInt 0…255 | 0 |
| Value for output value "True" | unsignedInt 0…255 | 0 |
| Percent value for output value "False" | list | 0 % |
| Percent value for output value "True" | list | 0 % |
| Forced guidance for output value "False" | list | 00 - no priority, Off |
| Forced guidance for output value "True" | list | 00 - no priority, Off |
| Internal input A | list | not active |
| Object number | unsignedInt 0…129 | 0 |
| Internal input B | list | not active |
| External input C | list | not active |
| Preset logic input after reset with | list | value "0" |
| External input D | list | not active |
| External input E | list | not active |
| External input F | list | not active |
| Logic function 2 | list | not active |
| Logic function 3 | list | not active |
| Logic function 4 | list | not active |
| Request inputs after bus power return | list | not active |
Version history
| Application | App no | Fingerprint | First seen | Size | File |
|---|---|---|---|---|---|
| Motivity, Secure 1.0 latest | $0694 | F07A | 2026-11-25 | 189 KB | Download |
About this file
This is the official ETS product database for the Tense MOT-Ix.02S KNX Motivity Ceiling, Secure (MOT-Ix.02S), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.
More from Tense
- MOT-LIx.02S KNX Motivity Line, Secure MOT-LIx.02S
- ETE-TSP4xx.01S Eternity Touch Smart Plus, 4 inch ETE-TSP4xx.01S
- ETE-TSP6xx.01S Eternity Touch Smart Plus, 6 inch ETE-TSP6xx.01S
- INT-Lxxxx1.02S Intensity 1 gang Landscape INT_Lxxx1.02S
- INT-Lxxxx2.02S Intensity 2 gang Landscape INT_Lxxx2.02S
- INT-Lxxxx4.02S Intensity 4 gang Landscape INT_Lxxx4.02S
- INT-xxxx1.02S Intensity 1 gang INT_xxx1.02S
- INT-xxxx2.02S Intensity 2 gang INT_xxx2.02S
- INT-xxxx4.02S Intensity 4 gang INT_xxx4.02S
- INT-xxxx8.02S Intensity 8 gang INT_xxx8.02S
- SER-xxxx1.02S Serenity 1 gang SER-xxxx1.02S
- SER-xxxx2.02S Serenity 2 gang SER-xxxx2.02S