Smart Building Services GmbH KNXdrive4U KNXdrive4U Product

KNXdrive4U Product KNXdrive4U

Smart Building Services GmbH · Order number KNXdrive4U · HVAC › Valve actuator

Download .knxprod Application for KNXdrive4u 0.2 · 144 KB

Product

ManufacturerSmart Building Services GmbH
Product nameKNXdrive4U Product
Order numberKNXdrive4U
HardwareKNXdrive4U Hardware
MediumKNX RF
Rail mountedNo
RegistrationRegistered · 2025-02-17
Languagesde-DE, fr-FR, es-ES, it-IT
Catalog entryM-029F_H-ZN.2D2050-3_HP-F023-02-47FC_CI-KNXdrive4U-1
Fingerprint47FC
SHA-256a6c12d6e72290e57990326fbbb1973b8f83e875a8462ab28da40f3b4201eb41c
First seen2026-11-25
Markets23 markets

Application program: Application for KNXdrive4u 0.2

Application number$F023
Version0.2
Mask versionMV-27B0 (RF System B)
KNX Data SecureNo
Minimum ETS version5.0
Parameters71
Group objects36
Group objects (36)
NoNameFunctionSizeDPTFlags
1{{0}}: Restart deviceRestarts device1 Bit1.17 triggerCWU
2{{0}}: Battery voltageActual battery voltage2 Bytes9.20 voltage (mV)CRT
3{{0}}: Battery %Actual battery percent1 Byte5.1 percentage (0..100%)CRT
4{{0}}: Battery 0%Battery gauge 0% dot1 Bit1.1 switchCRT
5{{0}}: Battery 25%Battery gauge 25% dot1 Bit1.1 switchCRT
6{{0}}: Battery 50%Battery gauge 50% dot1 Bit1.1 switchCRT
7{{0}}: Battery 75%Battery gauge 75% dot1 Bit1.1 switchCRT
8{{0}}: Battery 100%Battery gauge 100% dot1 BitDPT.1CRT
9{{0}}: Local temperatureTemperature mesures by device2 Bytes9.1 temperature (°C)CRT
10{{0}}: Set temperatureTemperature set by room thermostat2 Bytes9.1 temperature (°C)CWTU
11{{0}}: Room temperatureTemperature measured by room thermostat2 Bytes9.1 temperature (°C)CWTU
12{{0}}: HomingTriggers motor homing1 Bit1.17 triggerCWU
13{{0}}: Homing requiredIndicates device needs motor homing1 Bit1.5 alarmCRT
14{{0}}: Target position %Position to drive valve1 Byte5.1 percentage (0..100%)CWTU
15{{0}}: Target position stepPosition to drive valve2 Bytes7.2 time (ms)CWU
16{{0}}: Actual position %Actual valve position1 Byte5.1 percentage (0..100%)CRT
17{{0}}: Actual position stepActual valve position2 Bytes7.2 time (ms)CRT
18{{0}}: Energy harvester voltageActual voltage generated by energy harvester2 Bytes9.20 voltage (mV)CRT
19{{0}}: Energy harvester alarmAlarm indicating energy harvester voltage is below threshold1 Bit1.1 switchCRT
20{{0}}: Request datasIndicates device is now waiting for CO's1 Bit1.17 triggerCRT
21{{0}}: Send datasTriggers device sending all datas1 Bit1.17 triggerCWU
22{{0}}: Keep awakeTriggers delay to keep awake1 Bit1.17 triggerCWTU
23{{0}}: Awake statusActual awake status1 Bit1.2 booleanCRT
24{{0}}: Temperature alarm 1Status of temperature alarm 11 Bit1.1 switchCRT
25{{0}}: Temperature alarm 2Status of temperature alarm 21 Bit1.1 switchCRT
26{{0}}: Freezing alarmStatus of freezing alarm1 Bit1.1 switchCRT
27{{0}}: Battery alarmStatus of battery alarm1 Bit1.1 switchCRT
28{{0}}: ForcingForcing2 Bit2.6 binary value controlCWTU
29{{0}}: Anti-StuckInitiates anti-stuck movement1 Bit1.17 triggerCWU
30{{0}}: Heating modeStatus of heating mode1 Bit1.100 cooling/heatingCWTU
31{{0}}: Set temperature shiftShifting of set temperature2 Bytes9.1 temperature (°C)CWTU
32{{0}}: Calculated temperatureActual temperature computed using room thermostat and local sensor2 Bytes9.1 temperature (°C)CRT
33{{0}}: Resulting set temperatureStatus of resulting set temperature2 Bytes9.1 temperature (°C)CRT
34{{0}}: Actual internal regulator valuePosition in % calculated by internal regulator1 Byte5.1 percentage (0..100%)CRT
35{{0}}: HVAC mode from thermostatHVAC mode set by external thermostat1 Byte20.102 HVAC modeCWTU
36{{0}}: RHCC statusInternal RHCC status2 Bytes22.101 RHCC statusCRT
Parameters (61)
ParameterTypeDefault
Type of valvelistNormally opened (NO) valve
Local temperature sensor correctionsignedInt -50…500
Battery gaugelistDisplay as line
Valve_Max_pcunsignedInt 0…2550
Valve_Min_pcunsignedInt 0…2550
Mechanical valve offsetlist0 steps <-> No offset (standard)
Valve_Default_pcunsignedInt 0…255255
Min_pc_to_moveunsignedInt 0…2553
High_Forcing_pcunsignedInt 0…2550
OverHeating_Release_1unsignedInt 0…65535400
RF_Failure_pcunsignedInt 0…2550
OverHeating_Level_1unsignedInt 0…65535450
OverHeating_Release_2unsignedInt 0…65535500
OverHeating_Level_2unsignedInt 0…65535550
Wake up delay in heating modelist15 min.
Freezing_ReleaseunsignedInt 0…6553580
OverHeating_Level_2_Max_pcunsignedInt 0…2550
Energy harvester voltage to release alarmunsignedInt 250…1000250
Battery voltage to release alarmlist3
Operating mode after programminglistStock mode
Delay to operate anti-stuck movementslist180 days
Number of anti-stuck movements to operateunsignedInt 1…53
Energy harvester voltage to enter alarmunsignedInt 250…1000250
Wake up delay while not in heating modelist2 h
Low_Forcing_pcunsignedInt 0…2550
Freezing_Level_Min_pcunsignedInt 0…2550
Freezing_LevelunsignedInt 0…6553550
Battery_Empty_pcunsignedInt 0…25577
Battery voltage to enter alarmlist2.9
Delay to extend awakeness after receiving "Keep awake" COlist5 min.
Time to listen and process CO's after requesting data's from room controller, before entering sleep modelist2
OverHeating_Level_1_Max_pcunsignedInt 0…2550
Min. value to start opening valveunsignedInt 1…10010
Min. value for max opening valveunsignedInt 1…10085
Valve position while alarmunsignedInt 0…10030
Local temperature to enter alarmunsignedInt 15…6045
Local temperature to release alarmunsignedInt 14…5940
Local temperature to enter alarmunsignedInt 15…6055
Local temperature to release alarmunsignedInt 14…5950
Valve upper limit while alarmunsignedInt 0…10030
Valve upper limit while alarmunsignedInt 0…1000
Local temperature to enter alarmunsignedInt 5…155
Local temperature to release alarmunsignedInt 6…168
Valve lower limit while alarmunsignedInt 0…10030
Valve position while forcing '0'unsignedInt 0…10030
Valve position while forcing '1'unsignedInt 0…10030
Valve position at device start upunsignedInt 0…100100
Min. change to move valveunsignedInt 1…251
Valve position while regulator failureunsignedInt 0…10030
Proportional gainlist4K
Integratorlist120 min.
Set temperature, standby modeunsignedInt 80…300190
Device acts aslistValve actuator with integrated regulator
Actual room temperature computinglistRoom sensor 80% <> Internal sensor 20%
Set temperature, night modeunsignedInt 80…300180
Set temperature, comfort modeunsignedInt 80…300210
Device nametextMy KNXdrive4U
PI regulator settingslistStandard: 4K, 120 min.
Steps for min. openingunsignedInt 1…20001950
Upper opening limit (steps)unsignedInt 1…200050
Valve adjustinglistStandard settings

Version history

ApplicationApp noFingerprintFirst seenSizeFile
Application for KNXdrive4u 0.2 latest$F02347FC2026-11-25144 KBDownload

About this file

This is the official ETS product database for the Smart Building Services GmbH KNXdrive4U Product (KNXdrive4U), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.