Siemens 5WG1205-2AB_2 UP 205/x2 Touch Control TC5

UP 205/x2 Touch Control TC5 5WG1205-2AB_2

Siemens · Order number 5WG1205-2AB_2 · Touch panel

Download .knxprod 07B0 Touch Control SE 989603 0.3 · 2.5 MB

Product

ManufacturerSiemens
Product nameUP 205/x2 Touch Control TC5
Order number5WG1205-2AB_2
HardwareUP 205/x2 Touch Control TC5
MediumTwisted Pair
Bus current (mA)6
Rail mountedNo
RegistrationCertified · 2022-12-06
Languagesen-US, de-DE, it-IT, fr-FR, es-ES, sv-SE
Catalog entryM-0001_H-hp.5F00351.2F1-1_HP-9896-03-D467_CI-5WG1205.2D2AB.5F2-1
FingerprintD467
SHA-256289caa1425dfb77a8f722ec271464a8d932c6cc0bb25afb1b9f7860e3d1127aa
First seen2026-11-25
Markets59 markets

Application program: 07B0 Touch Control SE 989603 0.3

Application number$9896
Version0.3
Mask versionMV-07B0 (System B)
KNX Data SecureNo
Minimum ETS version5.0
Parameters12926
Group objects11128
Group objects (11128)
NoNameFunctionSizeDPTFlags
1Page 1-{{0:Icon 1}}Switching1 Bit1.1 switchCT
1Page 1-{{0:Icon 1}}Open / Close1 Bit1.9 open/closeCWT
1Page 1-{{0:Icon 1}}Up / Down1 Bit1.8 up/downCWT
1Page 1-{{0:Icon 1}}Send 1bit value1 Bit1.1 switchCT
1Page 1-{{0:Icon 1}}Send 2bit value2 Bit2.1 switch controlCT
1Page 1-{{0:Icon 1}}Send 4bit value4 Bit3.7 dimming controlCT
1Page 1-{{0:Icon 1}}Send 1byte unsigned value1 Byte5.10 counter pulses (0..255)CT
1Page 1-{{0:Icon 1}}Send 1byte percent value1 Byte5.1 percentage (0..100%)CT
1Page 1-{{0:Icon 1}}Send 2byte unsigned value2 Bytes7.1 pulsesCT
1Page 1-{{0:Icon 1}}Send 2byte signed value2 Bytes8.1 pulses differenceCT
1Page 1-{{0:Icon 1}}Recall / Save scene1 Byte18.1 scene controlCWT
1Page 1-{{0:Icon 1}}Send 4byte unsigned value4 Bytes12.1 counter pulses (unsigned)CT
1Page 1-{{0:Icon 1}}Send 4byte float value4 BytesDPT.14CT
1Page 1-{{0:Icon 1}}Recall / Save scene1 Byte18.1 scene controlCT
1Page 1-{{0:Icon 1}}Bell function1 Bit1.1 switchCT
2Page 1-{{0:Icon 1}}Send 2byte signed value, long2 Bytes8.1 pulses differenceCT
2Page 1-{{0:Icon 1}}Dim value1 Byte5.1 percentage (0..100%)CT
2Page 1-{{0:Icon 1}}Stop1 Bit1.7 stepCT
2Page 1-{{0:Icon 1}}Stop / Slat adj.1 Bit1.7 stepCT
2Page 1-{{0:Icon 1}}Send 1bit value, long1 Bit1.1 switchCT
2Page 1-{{0:Icon 1}}Send 2bit value, long2 Bit2.1 switch controlCT
2Page 1-{{0:Icon 1}}Send 4bit value, long4 Bit3.7 dimming controlCT
2Page 1-{{0:Icon 1}}Send 1byte unsigned value, long1 Byte5.10 counter pulses (0..255)CT
2Page 1-{{0:Icon 1}}Send 1byte percent value, long1 Byte5.1 percentage (0..100%)CT
2Page 1-{{0:Icon 1}}Send 2byte unsigned value, long2 Bytes7.1 pulsesCT
2Page 1-{{0:Icon 1}}Cool white brightness1 Byte5.1 percentage (0..100%)CT
2Page 1-{{0:Icon 1}}Send 4byte unsigned value, long4 Bytes12.1 counter pulses (unsigned)CT
2Page 1-{{0:Icon 1}}Send 4byte float value, long4 BytesDPT.14CT
3Page 1-{{0:Icon 1}}Status switching1 Bit1.1 switchCWTU
3Page 1-{{0:Icon 1}}Blind position1 Byte5.1 percentage (0..100%)CT
3Page 1-{{0:Icon 1}}Curtain position1 Byte5.1 percentage (0..100%)CT
3Page 1-{{0:Icon 1}}Display 1byte unsigned value1 Byte5.10 counter pulses (0..255)CWTU
3Page 1-{{0:Icon 1}}Display 1byte percentage value1 Byte5.1 percentage (0..100%)CWTU
3Page 1-{{0:Icon 1}}Display 2byte unsigned value2 Bytes7.1 pulsesCWTU
3Page 1-{{0:Icon 1}}Display 2byte signed value2 Bytes8.1 pulses differenceCWTU
3Page 1-{{0:Icon 1}}Display 2byte float value2 BytesDPT.9CWTU
3Page 1-{{0:Icon 1}}Display temperature value2 Bytes9.1 temperature (°C)CWTU
3Page 1-{{0:Icon 1}}Display pressure value2 Bytes9.6 pressure (Pa)CWTU
3Page 1-{{0:Icon 1}}Display humidity value2 Bytes9.7 humidity (%)CWTU
3Page 1-{{0:Icon 1}}Display CO2 value2 Bytes9.8 parts/million (ppm)CWTU
3Page 1-{{0:Icon 1}}Display air flow value2 Bytes9.9 air flow (m³/h)CWTU
3Page 1-{{0:Icon 1}}Display concentration value2 Bytes9.30 concentration (µg/m³)CWTU
3Page 1-{{0:Icon 1}}Display 4byte unsigned value4 Bytes12.1 counter pulses (unsigned)CWTU
3Page 1-{{0:Icon 1}}Display 4byte float value4 BytesDPT.14CWTU
3Page 1-{{0:Icon 1}}Display text14 Bytes16.1 Character String (ISO 8859-1)CW
3Page 1-{{0:Icon 1}}Display 1bit value1 Bit1.1 switchCWTU
4Page 1-{{0:Icon 1}}Dimming4 Bit3.7 dimming controlCWT
4Page 1-{{0:Icon 1}}Slat position1 Byte5.1 percentage (0..100%)CT
4Page 1-{{0:Icon 1}}Color temperature value2 Bytes7.600 absolute colour temperature (K)CT
4Page 1-{{0:Icon 1}}Warm white brightness1 Byte5.1 percentage (0..100%)CT
5Page 1-{{0:Icon 1}}Status blind position1 Byte5.1 percentage (0..100%)CWTU
5Page 1-{{0:Icon 1}}Status curtain position1 Byte5.1 percentage (0..100%)CWTU
5Page 1-{{0:Icon 1}}Status dim value1 Byte5.1 percentage (0..100%)CWTU
5Page 1-{{0:Icon 1}}Cool white brightness, status1 Byte5.1 percentage (0..100%)CWTU
6Page 1-{{0:Icon 1}}Status slat position1 Byte5.1 percentage (0..100%)CWTU
6Page 1-{{0:Icon 1}}Status color temperature value2 Bytes7.600 absolute colour temperature (K)CWTU
6Page 1-{{0:Icon 1}}Warm white brightness, status1 Byte5.1 percentage (0..100%)CWTU
7Page 1-{{0:Icon 2}}Switching1 Bit1.1 switchCT
7Page 1-{{0:Icon 2}}Send 1bit value1 Bit1.1 switchCT
7Page 1-{{0:Icon 2}}Send 2bit value2 Bit2.1 switch controlCT
7Page 1-{{0:Icon 2}}Send 4bit value4 Bit3.7 dimming controlCT
7Page 1-{{0:Icon 2}}Send 1byte unsigned value1 Byte5.10 counter pulses (0..255)CT
7Page 1-{{0:Icon 2}}Send 1byte percent value1 Byte5.1 percentage (0..100%)CT
7Page 1-{{0:Icon 2}}Send 2byte unsigned value2 Bytes7.1 pulsesCT
7Page 1-{{0:Icon 2}}Send 2byte signed value2 Bytes8.1 pulses differenceCT
7Page 1-{{0:Icon 2}}Open / Close1 Bit1.9 open/closeCWT
7Page 1-{{0:Icon 2}}Up / Down1 Bit1.8 up/downCWT
7Page 1-{{0:Icon 2}}Recall / Save scene1 Byte18.1 scene controlCWT
7Page 1-{{0:Icon 2}}Recall / Save scene1 Byte18.1 scene controlCT
7Page 1-{{0:Icon 2}}Send 4byte unsigned value4 Bytes12.1 counter pulses (unsigned)CT
7Page 1-{{0:Icon 2}}Send 4byte float value4 BytesDPT.14CT
7Page 1-{{0:Icon 2}}Bell function1 Bit1.1 switchCT
8Page 1-{{0:Icon 2}}Dim value1 Byte5.1 percentage (0..100%)CT
8Page 1-{{0:Icon 2}}Send 1bit value, long1 Bit1.1 switchCT
8Page 1-{{0:Icon 2}}Send 2bit value, long2 Bit2.1 switch controlCT
8Page 1-{{0:Icon 2}}Send 4bit value, long4 Bit3.7 dimming controlCT
8Page 1-{{0:Icon 2}}Send 1byte unsigned value, long1 Byte5.10 counter pulses (0..255)CT
8Page 1-{{0:Icon 2}}Send 1byte percent value, long1 Byte5.1 percentage (0..100%)CT
8Page 1-{{0:Icon 2}}Send 2byte unsigned value, long2 Bytes7.1 pulsesCT
8Page 1-{{0:Icon 2}}Send 2byte signed value, long2 Bytes8.1 pulses differenceCT
8Page 1-{{0:Icon 2}}Stop1 Bit1.7 stepCT
8Page 1-{{0:Icon 2}}Stop / Slat adj.1 Bit1.7 stepCT
8Page 1-{{0:Icon 2}}Cool white brightness1 Byte5.1 percentage (0..100%)CT
8Page 1-{{0:Icon 2}}Send 4byte unsigned value4 Bytes12.1 counter pulses (unsigned)CT
8Page 1-{{0:Icon 2}}Send 4byte float value, long4 BytesDPT.14CT
9Page 1-{{0:Icon 2}}Status switching1 Bit1.1 switchCWTU
9Page 1-{{0:Icon 2}}Blind position1 Byte5.1 percentage (0..100%)CT
9Page 1-{{0:Icon 2}}Curtain position1 Byte5.1 percentage (0..100%)CT
9Page 1-{{0:Icon 2}}Display 1byte unsigned value1 Byte5.10 counter pulses (0..255)CWTU
9Page 1-{{0:Icon 2}}Display 1byte percentage value1 Byte5.1 percentage (0..100%)CWTU
9Page 1-{{0:Icon 2}}Display 2byte unsigned value2 Bytes7.1 pulsesCWTU
9Page 1-{{0:Icon 2}}Display 2byte signed value2 Bytes8.1 pulses differenceCWTU
9Page 1-{{0:Icon 2}}Display 2byte float value2 BytesDPT.9CWTU
9Page 1-{{0:Icon 2}}Display temperature value2 Bytes9.1 temperature (°C)CWTU
9Page 1-{{0:Icon 2}}Display pressure value2 Bytes9.6 pressure (Pa)CWTU
9Page 1-{{0:Icon 2}}Display humidity value2 Bytes9.7 humidity (%)CWTU
9Page 1-{{0:Icon 2}}Display CO2 value2 Bytes9.8 parts/million (ppm)CWTU
9Page 1-{{0:Icon 2}}Display air flow value2 Bytes9.9 air flow (m³/h)CWTU
9Page 1-{{0:Icon 2}}Display concentration value2 Bytes9.30 concentration (µg/m³)CWTU
9Page 1-{{0:Icon 2}}Display 4byte unsigned value4 Bytes12.1 counter pulses (unsigned)CWTU
9Page 1-{{0:Icon 2}}Display 4byte float value4 BytesDPT.14CWTU
9Page 1-{{0:Icon 2}}Display text14 Bytes16.1 Character String (ISO 8859-1)CW
9Page 1-{{0:Icon 2}}Display 1bit value1 Bit1.1 switchCWTU
10Page 1-{{0:Icon 2}}Dimming4 Bit3.7 dimming controlCWT
10Page 1-{{0:Icon 2}}Slat position1 Byte5.1 percentage (0..100%)CT
10Page 1-{{0:Icon 2}}Color temperature value2 Bytes7.600 absolute colour temperature (K)CT
10Page 1-{{0:Icon 2}}Warm white brightness1 Byte5.1 percentage (0..100%)CT
11Page 1-{{0:Icon 2}}Status blind position1 Byte5.1 percentage (0..100%)CWTU
11Page 1-{{0:Icon 2}}Status curtain position1 Byte5.1 percentage (0..100%)CWTU
11Page 1-{{0:Icon 2}}Status dim value1 Byte5.1 percentage (0..100%)CWTU
11Page 1-{{0:Icon 2}}Cool white brightness, status1 Byte5.1 percentage (0..100%)CWTU
12Page 1-{{0:Icon 2}}Status slat position1 Byte5.1 percentage (0..100%)CWTU
12Page 1-{{0:Icon 2}}Status color temperature value2 Bytes7.600 absolute colour temperature (K)CWTU
12Page 1-{{0:Icon 2}}Warm white brightness, status1 Byte5.1 percentage (0..100%)CWTU
13Page 1-{{0:Icon 3}}Switching1 Bit1.1 switchCT
13Page 1-{{0:Icon 3}}Send 1bit value1 Bit1.1 switchCT
13Page 1-{{0:Icon 3}}Send 2bit value2 Bit2.1 switch controlCT
13Page 1-{{0:Icon 3}}Send 4bit value4 Bit3.7 dimming controlCT
13Page 1-{{0:Icon 3}}Send 1byte unsigned value1 Byte5.10 counter pulses (0..255)CT
13Page 1-{{0:Icon 3}}Send 1byte percent value1 Byte5.1 percentage (0..100%)CT
13Page 1-{{0:Icon 3}}Send 2byte unsigned value2 Bytes7.1 pulsesCT
13Page 1-{{0:Icon 3}}Send 2byte signed value2 Bytes8.1 pulses differenceCT
13Page 1-{{0:Icon 3}}Open / Close1 Bit1.9 open/closeCWT
13Page 1-{{0:Icon 3}}Up / Down1 Bit1.8 up/downCWT
13Page 1-{{0:Icon 3}}Recall / Save scene1 Byte18.1 scene controlCWT
13Page 1-{{0:Icon 3}}Recall / Save scene1 Byte18.1 scene controlCT
13Page 1-{{0:Icon 3}}Send 4byte unsigned value4 Bytes12.1 counter pulses (unsigned)CT
13Page 1-{{0:Icon 3}}Send 4byte float value4 BytesDPT.14CT
13Page 1-{{0:Icon 3}}Bell function1 Bit1.1 switchCT
14Page 1-{{0:Icon 3}}Dim value1 Byte5.1 percentage (0..100%)CT
14Page 1-{{0:Icon 3}}Send 1bit value, long1 Bit1.1 switchCT
14Page 1-{{0:Icon 3}}Send 2bit value, long2 Bit2.1 switch controlCT
14Page 1-{{0:Icon 3}}Send 4bit value, long4 Bit3.7 dimming controlCT
14Page 1-{{0:Icon 3}}Send 1byte unsigned value, long1 Byte5.10 counter pulses (0..255)CT
14Page 1-{{0:Icon 3}}Send 1byte percent value, long1 Byte5.1 percentage (0..100%)CT
14Page 1-{{0:Icon 3}}Send 2byte unsigned value, long2 Bytes7.1 pulsesCT
14Page 1-{{0:Icon 3}}Send 2byte signed value, long2 Bytes8.1 pulses differenceCT
14Page 1-{{0:Icon 3}}Stop1 Bit1.7 stepCT
14Page 1-{{0:Icon 3}}Stop / Slat adj.1 Bit1.7 stepCT
14Page 1-{{0:Icon 3}}Cool white brightness1 Byte5.1 percentage (0..100%)CT
14Page 1-{{0:Icon 3}}Send 4byte unsigned value, long4 Bytes12.1 counter pulses (unsigned)CT
14Page 1-{{0:Icon 3}}Send 4byte float value, long4 BytesDPT.14CT
15Page 1-{{0:Icon 3}}Status switching1 Bit1.1 switchCWTU
15Page 1-{{0:Icon 3}}Blind position1 Byte5.1 percentage (0..100%)CT
15Page 1-{{0:Icon 3}}Curtain position1 Byte5.1 percentage (0..100%)CT
15Page 1-{{0:Icon 3}}Display 1byte unsigned value1 Byte5.10 counter pulses (0..255)CWTU
15Page 1-{{0:Icon 3}}Display 1byte percentage value1 Byte5.1 percentage (0..100%)CWTU
15Page 1-{{0:Icon 3}}Display 2byte unsigned value2 Bytes7.1 pulsesCWTU
15Page 1-{{0:Icon 3}}Display 2byte signed value2 Bytes8.1 pulses differenceCWTU
15Page 1-{{0:Icon 3}}Display 2byte float value2 BytesDPT.9CWTU
15Page 1-{{0:Icon 3}}Display temperature value2 Bytes9.1 temperature (°C)CWTU
15Page 1-{{0:Icon 3}}Display pressure value2 Bytes9.6 pressure (Pa)CWTU
15Page 1-{{0:Icon 3}}Display humidity value2 Bytes9.7 humidity (%)CWTU
15Page 1-{{0:Icon 3}}Display CO2 value2 Bytes9.8 parts/million (ppm)CWTU
15Page 1-{{0:Icon 3}}Display air flow value2 Bytes9.9 air flow (m³/h)CWTU
15Page 1-{{0:Icon 3}}Display concentration value2 Bytes9.30 concentration (µg/m³)CWTU
15Page 1-{{0:Icon 3}}Display 4byte unsigned value4 Bytes12.1 counter pulses (unsigned)CWTU
15Page 1-{{0:Icon 3}}Display 4byte float value4 BytesDPT.14CWTU
15Page 1-{{0:Icon 3}}Display text14 Bytes16.1 Character String (ISO 8859-1)CW
15Page 1-{{0:Icon 3}}Display 1bit value1 Bit1.1 switchCWTU
16Page 1-{{0:Icon 3}}Dimming4 Bit3.7 dimming controlCWT
16Page 1-{{0:Icon 3}}Slat position1 Byte5.1 percentage (0..100%)CT
16Page 1-{{0:Icon 3}}Color temperature value2 Bytes7.600 absolute colour temperature (K)CT
16Page 1-{{0:Icon 3}}Warm white brightness1 Byte5.1 percentage (0..100%)CT
17Page 1-{{0:Icon 3}}Status blind position1 Byte5.1 percentage (0..100%)CWTU
17Page 1-{{0:Icon 3}}Status curtain position1 Byte5.1 percentage (0..100%)CWTU
17Page 1-{{0:Icon 3}}Status dim value1 Byte5.1 percentage (0..100%)CWTU
17Page 1-{{0:Icon 3}}Cool white brightness, status1 Byte5.1 percentage (0..100%)CWTU
18Page 1-{{0:Icon 3}}Status slat position1 Byte5.1 percentage (0..100%)CWTU
18Page 1-{{0:Icon 3}}Status color temperature value2 Bytes7.600 absolute colour temperature (K)CWTU
18Page 1-{{0:Icon 3}}Warm white brightness, status1 Byte5.1 percentage (0..100%)CWTU
19Page 1-{{0:Icon 4}}Send 2byte unsigned value2 Bytes7.1 pulsesCT
19Page 1-{{0:Icon 4}}Switching1 Bit1.1 switchCT
19Page 1-{{0:Icon 4}}Send 1bit value1 Bit1.1 switchCT
19Page 1-{{0:Icon 4}}Send 2bit value2 Bit2.1 switch controlCT
19Page 1-{{0:Icon 4}}Send 4bit value4 Bit3.7 dimming controlCT
19Page 1-{{0:Icon 4}}Send 1byte unsigned value1 Byte5.10 counter pulses (0..255)CT
19Page 1-{{0:Icon 4}}Send 1byte percent value1 Byte5.1 percentage (0..100%)CT
19Page 1-{{0:Icon 4}}Send 2byte signed value2 Bytes8.1 pulses differenceCT
19Page 1-{{0:Icon 4}}Open / Close1 Bit1.9 open/closeCWT
19Page 1-{{0:Icon 4}}Up / Down1 Bit1.8 up/downCWT
19Page 1-{{0:Icon 4}}Recall / Save scene1 Byte18.1 scene controlCWT
19Page 1-{{0:Icon 4}}Recall / Save scene1 Byte18.1 scene controlCT
19Page 1-{{0:Icon 4}}Send 4byte unsigned value4 Bytes12.1 counter pulses (unsigned)CT
19Page 1-{{0:Icon 4}}Send 4byte float value4 BytesDPT.14CT
19Page 1-{{0:Icon 4}}Bell function1 Bit1.1 switchCT
20Page 1-{{0:Icon 4}}Send 2byte signed value, long2 Bytes8.1 pulses differenceCT
20Page 1-{{0:Icon 4}}Dim value1 Byte5.1 percentage (0..100%)CT
20Page 1-{{0:Icon 4}}Send 1bit value, long1 Bit1.1 switchCT
20Page 1-{{0:Icon 4}}Send 2bit value, long2 Bit2.1 switch controlCT
20Page 1-{{0:Icon 4}}Send 4bit value, long4 Bit3.7 dimming controlCT
20Page 1-{{0:Icon 4}}Send 1byte unsigned value, long1 Byte5.10 counter pulses (0..255)CT
20Page 1-{{0:Icon 4}}Send 1byte percent value, long1 Byte5.1 percentage (0..100%)CT
20Page 1-{{0:Icon 4}}Send 2byte unsigned value, long2 Bytes7.1 pulsesCT
20Page 1-{{0:Icon 4}}Stop1 Bit1.7 stepCT
20Page 1-{{0:Icon 4}}Stop / Slat adj.1 Bit1.7 stepCT
20Page 1-{{0:Icon 4}}Cool white brightness1 Byte5.1 percentage (0..100%)CT
20Page 1-{{0:Icon 4}}Send 4byte unsigned value, long4 Bytes12.1 counter pulses (unsigned)CT
20Page 1-{{0:Icon 4}}Send 4byte float value, long4 BytesDPT.14CT
21Page 1-{{0:Icon 4}}Status switching1 Bit1.1 switchCWTU
21Page 1-{{0:Icon 4}}Blind position1 Byte5.1 percentage (0..100%)CT
21Page 1-{{0:Icon 4}}Curtain position1 Byte5.1 percentage (0..100%)CT
21Page 1-{{0:Icon 4}}Display 1byte unsigned value1 Byte5.10 counter pulses (0..255)CWTU
21Page 1-{{0:Icon 4}}Display 1byte percentage value1 Byte5.1 percentage (0..100%)CWTU
21Page 1-{{0:Icon 4}}Display 2byte unsigned value2 Bytes7.1 pulsesCWTU
21Page 1-{{0:Icon 4}}Display 2byte signed value2 Bytes8.1 pulses differenceCWTU
21Page 1-{{0:Icon 4}}Display 2byte float value2 BytesDPT.9CWTU
21Page 1-{{0:Icon 4}}Display temperature value2 Bytes9.1 temperature (°C)CWTU
21Page 1-{{0:Icon 4}}Display pressure value2 Bytes9.6 pressure (Pa)CWTU
21Page 1-{{0:Icon 4}}Display humidity value2 Bytes9.7 humidity (%)CWTU
21Page 1-{{0:Icon 4}}Display CO2 value2 Bytes9.8 parts/million (ppm)CWTU
21Page 1-{{0:Icon 4}}Display air flow value2 Bytes9.9 air flow (m³/h)CWTU
21Page 1-{{0:Icon 4}}Display concentration value2 Bytes9.30 concentration (µg/m³)CWTU
21Page 1-{{0:Icon 4}}Display 4byte unsigned value4 Bytes12.1 counter pulses (unsigned)CWTU
21Page 1-{{0:Icon 4}}Display 4byte float value4 BytesDPT.14CWTU
21Page 1-{{0:Icon 4}}Display text14 Bytes16.1 Character String (ISO 8859-1)CW
21Page 1-{{0:Icon 4}}Display 1bit value1 Bit1.1 switchCWTU
22Page 1-{{0:Icon 4}}Slat position1 Byte5.1 percentage (0..100%)CT
22Page 1-{{0:Icon 4}}Dimming4 Bit3.7 dimming controlCWT
22Page 1-{{0:Icon 4}}Color temperature value2 Bytes7.600 absolute colour temperature (K)CT
22Page 1-{{0:Icon 4}}Warm white brightness1 Byte5.1 percentage (0..100%)CT
23Page 1-{{0:Icon 4}}Status blind position1 Byte5.1 percentage (0..100%)CWTU
23Page 1-{{0:Icon 4}}Status curtain position1 Byte5.1 percentage (0..100%)CWTU
23Page 1-{{0:Icon 4}}Status dim value1 Byte5.1 percentage (0..100%)CWTU
23Page 1-{{0:Icon 4}}Cool white brightness, status1 Byte5.1 percentage (0..100%)CWTU
24Page 1-{{0:Icon 4}}Status slat position1 Byte5.1 percentage (0..100%)CWTU
24Page 1-{{0:Icon 4}}Status color temperature value2 Bytes7.600 absolute colour temperature (K)CWTU
24Page 1-{{0:Icon 4}}Warm white brightness, status1 Byte5.1 percentage (0..100%)CWTU
25Page 1-{{0:Icon 5}}Send 2byte unsigned value2 Bytes7.1 pulsesCT
25Page 1-{{0:Icon 5}}Switching1 Bit1.1 switchCT
25Page 1-{{0:Icon 5}}Send 1bit value1 Bit1.1 switchCT
25Page 1-{{0:Icon 5}}Send 2bit value2 Bit2.1 switch controlCT
25Page 1-{{0:Icon 5}}Send 4bit value4 Bit3.7 dimming controlCT
25Page 1-{{0:Icon 5}}Send 1byte unsigned value1 Byte5.10 counter pulses (0..255)CT
25Page 1-{{0:Icon 5}}Send 1byte percent value1 Byte5.1 percentage (0..100%)CT
25Page 1-{{0:Icon 5}}Send 2byte signed value2 Bytes8.1 pulses differenceCT
25Page 1-{{0:Icon 5}}Open / Close1 Bit1.9 open/closeCWT
25Page 1-{{0:Icon 5}}Up / Down1 Bit1.8 up/downCWT
25Page 1-{{0:Icon 5}}Recall / Save scene1 Byte18.1 scene controlCWT
25Page 1-{{0:Icon 5}}Recall / Save scene1 Byte18.1 scene controlCT
25Page 1-{{0:Icon 5}}Send 4byte unsigned value4 Bytes12.1 counter pulses (unsigned)CT
25Page 1-{{0:Icon 5}}Send 4byte float value4 BytesDPT.14CT
25Page 1-{{0:Icon 5}}Bell function1 Bit1.1 switchCT
26Page 1-{{0:Icon 5}}Send 2byte signed value, long2 Bytes8.1 pulses differenceCT
26Page 1-{{0:Icon 5}}Dim value1 Byte5.1 percentage (0..100%)CT
26Page 1-{{0:Icon 5}}Send 1bit value, long1 Bit1.1 switchCT
26Page 1-{{0:Icon 5}}Send 2bit value, long2 Bit2.1 switch controlCT
26Page 1-{{0:Icon 5}}Send 4bit value, long4 Bit3.7 dimming controlCT
26Page 1-{{0:Icon 5}}Send 1byte unsigned value, long1 Byte5.10 counter pulses (0..255)CT
26Page 1-{{0:Icon 5}}Send 1byte percent value, long1 Byte5.1 percentage (0..100%)CT
26Page 1-{{0:Icon 5}}Send 2byte unsigned value, long2 Bytes7.1 pulsesCT
26Page 1-{{0:Icon 5}}Stop1 Bit1.7 stepCT
26Page 1-{{0:Icon 5}}Stop / Slat adj.1 Bit1.7 stepCT
26Page 1-{{0:Icon 5}}Cool white brightness1 Byte5.1 percentage (0..100%)CT
26Page 1-{{0:Icon 5}}Send 4byte unsigned value, long4 Bytes12.1 counter pulses (unsigned)CT
26Page 1-{{0:Icon 5}}Send 4byte float value, long4 BytesDPT.14CT
27Page 1-{{0:Icon 5}}Status switching1 Bit1.1 switchCWTU
27Page 1-{{0:Icon 5}}Blind position1 Byte5.1 percentage (0..100%)CT
27Page 1-{{0:Icon 5}}Curtain position1 Byte5.1 percentage (0..100%)CT
27Page 1-{{0:Icon 5}}Display 1byte unsigned value1 Byte5.10 counter pulses (0..255)CWTU
27Page 1-{{0:Icon 5}}Display 1byte percentage value1 Byte5.1 percentage (0..100%)CWTU
27Page 1-{{0:Icon 5}}Display 2byte unsigned value2 Bytes7.1 pulsesCWTU
27Page 1-{{0:Icon 5}}Display 2byte signed value2 Bytes8.1 pulses differenceCWTU
27Page 1-{{0:Icon 5}}Display 2byte float value2 BytesDPT.9CWTU
27Page 1-{{0:Icon 5}}Display temperature value2 Bytes9.1 temperature (°C)CWTU
27Page 1-{{0:Icon 5}}Display pressure value2 Bytes9.6 pressure (Pa)CWTU
27Page 1-{{0:Icon 5}}Display humidity value2 Bytes9.7 humidity (%)CWTU
27Page 1-{{0:Icon 5}}Display CO2 value2 Bytes9.8 parts/million (ppm)CWTU
27Page 1-{{0:Icon 5}}Display air flow value2 Bytes9.9 air flow (m³/h)CWTU
27Page 1-{{0:Icon 5}}Display concentration value2 Bytes9.30 concentration (µg/m³)CWTU
27Page 1-{{0:Icon 5}}Display 4byte unsigned value4 Bytes12.1 counter pulses (unsigned)CWTU
27Page 1-{{0:Icon 5}}Display 4byte float value4 BytesDPT.14CWTU
27Page 1-{{0:Icon 5}}Display text14 Bytes16.1 Character String (ISO 8859-1)CW
27Page 1-{{0:Icon 5}}Display 1bit value1 Bit1.1 switchCWTU
28Page 1-{{0:Icon 5}}Slat position1 Byte5.1 percentage (0..100%)CT
28Page 1-{{0:Icon 5}}Dimming4 Bit3.7 dimming controlCWT
28Page 1-{{0:Icon 5}}Color temperature value2 Bytes7.600 absolute colour temperature (K)CT
28Page 1-{{0:Icon 5}}Warm white brightness1 Byte5.1 percentage (0..100%)CT
29Page 1-{{0:Icon 5}}Status blind position1 Byte5.1 percentage (0..100%)CWTU
29Page 1-{{0:Icon 5}}Status curtain position1 Byte5.1 percentage (0..100%)CWTU
29Page 1-{{0:Icon 5}}Status dim value1 Byte5.1 percentage (0..100%)CWTU
29Page 1-{{0:Icon 5}}Cool white brightness, status1 Byte5.1 percentage (0..100%)CWTU
30Page 1-{{0:Icon 5}}Status slat position1 Byte5.1 percentage (0..100%)CWTU
30Page 1-{{0:Icon 5}}Status color temperature value2 Bytes7.600 absolute colour temperature (K)CWTU
30Page 1-{{0:Icon 5}}Warm white brightness, status1 Byte5.1 percentage (0..100%)CWTU
31Page 1-{{0:Icon 6}}Send 2byte unsigned value2 Bytes7.1 pulsesCT
31Page 1-{{0:Icon 6}}Switching1 Bit1.1 switchCT
31Page 1-{{0:Icon 6}}Send 1bit value1 Bit1.1 switchCT
31Page 1-{{0:Icon 6}}Send 2bit value2 Bit2.1 switch controlCT
31Page 1-{{0:Icon 6}}Send 4bit value4 Bit3.7 dimming controlCT
31Page 1-{{0:Icon 6}}Send 1byte unsigned value1 Byte5.10 counter pulses (0..255)CT
31Page 1-{{0:Icon 6}}Send 1byte percent value1 Byte5.1 percentage (0..100%)CT
31Page 1-{{0:Icon 6}}Send 2byte signed value2 Bytes8.1 pulses differenceCT
31Page 1-{{0:Icon 6}}Open / Close1 Bit1.9 open/closeCWT
31Page 1-{{0:Icon 6}}Up / Down1 Bit1.8 up/downCWT
31Page 1-{{0:Icon 6}}Recall / Save scene1 Byte18.1 scene controlCWT
31Page 1-{{0:Icon 6}}Recall / Save scene1 Byte18.1 scene controlCT
31Page 1-{{0:Icon 6}}Send 4byte unsigned value4 Bytes12.1 counter pulses (unsigned)CT
31Page 1-{{0:Icon 6}}Send 4byte float value4 BytesDPT.14CT
31Page 1-{{0:Icon 6}}Bell function1 Bit1.1 switchCT
32Page 1-{{0:Icon 6}}Send 2byte signed value, long2 Bytes8.1 pulses differenceCT
32Page 1-{{0:Icon 6}}Dim value1 Byte5.1 percentage (0..100%)CT
32Page 1-{{0:Icon 6}}Send 1bit value, long1 Bit1.1 switchCT
32Page 1-{{0:Icon 6}}Send 2bit value, long2 Bit2.1 switch controlCT
32Page 1-{{0:Icon 6}}Send 4bit value, long4 Bit3.7 dimming controlCT
32Page 1-{{0:Icon 6}}Send 1byte unsigned value, long1 Byte5.10 counter pulses (0..255)CT
32Page 1-{{0:Icon 6}}Send 1byte percent value, long1 Byte5.1 percentage (0..100%)CT
32Page 1-{{0:Icon 6}}Send 2byte unsigned value, long2 Bytes7.1 pulsesCT
32Page 1-{{0:Icon 6}}Stop1 Bit1.7 stepCT
32Page 1-{{0:Icon 6}}Stop / Slat adj.1 Bit1.7 stepCT
32Page 1-{{0:Icon 6}}Cool white brightness1 Byte5.1 percentage (0..100%)CT
32Page 1-{{0:Icon 6}}Send 4byte unsigned value, long4 Bytes12.1 counter pulses (unsigned)CT
32Page 1-{{0:Icon 6}}Send 4byte float value, long4 BytesDPT.14CT
33Page 1-{{0:Icon 6}}Status switching1 Bit1.1 switchCWTU
33Page 1-{{0:Icon 6}}Blind position1 Byte5.1 percentage (0..100%)CT
33Page 1-{{0:Icon 6}}Curtain position1 Byte5.1 percentage (0..100%)CT
33Page 1-{{0:Icon 6}}Display 1byte unsigned value1 Byte5.10 counter pulses (0..255)CWTU
33Page 1-{{0:Icon 6}}Display 1byte percentage value1 Byte5.1 percentage (0..100%)CWTU
33Page 1-{{0:Icon 6}}Display 2byte unsigned value2 Bytes7.1 pulsesCWTU
33Page 1-{{0:Icon 6}}Display 2byte signed value2 Bytes8.1 pulses differenceCWTU
33Page 1-{{0:Icon 6}}Display 2byte float value2 BytesDPT.9CWTU
33Page 1-{{0:Icon 6}}Display temperature value2 Bytes9.1 temperature (°C)CWTU
33Page 1-{{0:Icon 6}}Display pressure value2 Bytes9.6 pressure (Pa)CWTU
33Page 1-{{0:Icon 6}}Display humidity value2 Bytes9.7 humidity (%)CWTU
33Page 1-{{0:Icon 6}}Display CO2 value2 Bytes9.8 parts/million (ppm)CWTU
33Page 1-{{0:Icon 6}}Display air flow value2 Bytes9.9 air flow (m³/h)CWTU
33Page 1-{{0:Icon 6}}Display concentration value2 Bytes9.30 concentration (µg/m³)CWTU
33Page 1-{{0:Icon 6}}Display 4byte unsigned value4 Bytes12.1 counter pulses (unsigned)CWTU
33Page 1-{{0:Icon 6}}Display 4byte float value4 BytesDPT.14CWTU
33Page 1-{{0:Icon 6}}Display text14 Bytes16.1 Character String (ISO 8859-1)CW
33Page 1-{{0:Icon 6}}Display 1bit value1 Bit1.1 switchCWTU
34Page 1-{{0:Icon 6}}Slat position1 Byte5.1 percentage (0..100%)CT
34Page 1-{{0:Icon 6}}Dimming4 Bit3.7 dimming controlCWT
34Page 1-{{0:Icon 6}}Color temperature value2 Bytes7.600 absolute colour temperature (K)CT
34Page 1-{{0:Icon 6}}Warm white brightness1 Byte5.1 percentage (0..100%)CT
35Page 1-{{0:Icon 6}}Status blind position1 Byte5.1 percentage (0..100%)CWTU
35Page 1-{{0:Icon 6}}Status curtain position1 Byte5.1 percentage (0..100%)CWTU
35Page 1-{{0:Icon 6}}Status dim value1 Byte5.1 percentage (0..100%)CWTU
35Page 1-{{0:Icon 6}}Cool white brightness, status1 Byte5.1 percentage (0..100%)CWTU
36Page 1-{{0:Icon 6}}Status slat position1 Byte5.1 percentage (0..100%)CWTU
36Page 1-{{0:Icon 6}}Status color temperature value2 Bytes7.600 absolute colour temperature (K)CWTU
36Page 1-{{0:Icon 6}}Warm white brightness, status1 Byte5.1 percentage (0..100%)CWTU
37Page 1-{{0:Icon 7}}Send 2byte unsigned value2 Bytes7.1 pulsesCT
37Page 1-{{0:Icon 7}}Switching1 Bit1.1 switchCT
37Page 1-{{0:Icon 7}}Send 1bit value1 Bit1.1 switchCT
37Page 1-{{0:Icon 7}}Send 2bit value2 Bit2.1 switch controlCT
37Page 1-{{0:Icon 7}}Send 4bit value4 Bit3.7 dimming controlCT
37Page 1-{{0:Icon 7}}Send 1byte unsigned value1 Byte5.10 counter pulses (0..255)CT
37Page 1-{{0:Icon 7}}Send 1byte percent value1 Byte5.1 percentage (0..100%)CT
37Page 1-{{0:Icon 7}}Send 2byte signed value2 Bytes8.1 pulses differenceCT
37Page 1-{{0:Icon 7}}Open / Close1 Bit1.9 open/closeCWT
37Page 1-{{0:Icon 7}}Up / Down1 Bit1.8 up/downCWT
37Page 1-{{0:Icon 7}}Recall / Save scene1 Byte18.1 scene controlCWT
37Page 1-{{0:Icon 7}}Recall / Save scene1 Byte18.1 scene controlCT
37Page 1-{{0:Icon 7}}Send 4byte unsigned value4 Bytes12.1 counter pulses (unsigned)CT
37Page 1-{{0:Icon 7}}Send 4byte float value4 BytesDPT.14CT
37Page 1-{{0:Icon 7}}Bell function1 Bit1.1 switchCT
38Page 1-{{0:Icon 7}}Send 2byte signed value, long2 Bytes8.1 pulses differenceCT
38Page 1-{{0:Icon 7}}Dim value1 Byte5.1 percentage (0..100%)CT
38Page 1-{{0:Icon 7}}Send 1bit value, long1 Bit1.1 switchCT
38Page 1-{{0:Icon 7}}Send 2bit value, long2 Bit2.1 switch controlCT
38Page 1-{{0:Icon 7}}Send 4bit value, long4 Bit3.7 dimming controlCT
38Page 1-{{0:Icon 7}}Send 1byte unsigned value, long1 Byte5.10 counter pulses (0..255)CT
38Page 1-{{0:Icon 7}}Send 1byte percent value, long1 Byte5.1 percentage (0..100%)CT
38Page 1-{{0:Icon 7}}Send 2byte unsigned value, long2 Bytes7.1 pulsesCT
38Page 1-{{0:Icon 7}}Stop1 Bit1.7 stepCT
38Page 1-{{0:Icon 7}}Stop / Slat adj.1 Bit1.7 stepCT
38Page 1-{{0:Icon 7}}Cool white brightness1 Byte5.1 percentage (0..100%)CT
38Page 1-{{0:Icon 7}}Send 4byte unsigned value, long4 Bytes12.1 counter pulses (unsigned)CT
38Page 1-{{0:Icon 7}}Send 4byte float value, long4 BytesDPT.14CT
39Page 1-{{0:Icon 7}}Status switching1 Bit1.1 switchCWTU
39Page 1-{{0:Icon 7}}Blind position1 Byte5.1 percentage (0..100%)CT
39Page 1-{{0:Icon 7}}Curtain position1 Byte5.1 percentage (0..100%)CT
39Page 1-{{0:Icon 7}}Display 1byte unsigned value1 Byte5.10 counter pulses (0..255)CWTU
39Page 1-{{0:Icon 7}}Display 1byte percentage value1 Byte5.1 percentage (0..100%)CWTU
39Page 1-{{0:Icon 7}}Display 2byte unsigned value2 Bytes7.1 pulsesCWTU
39Page 1-{{0:Icon 7}}Display 2byte signed value2 Bytes8.1 pulses differenceCWTU
39Page 1-{{0:Icon 7}}Display 2byte float value2 BytesDPT.9CWTU
39Page 1-{{0:Icon 7}}Display temperature value2 Bytes9.1 temperature (°C)CWTU
39Page 1-{{0:Icon 7}}Display pressure value2 Bytes9.6 pressure (Pa)CWTU
39Page 1-{{0:Icon 7}}Display humidity value2 Bytes9.7 humidity (%)CWTU
39Page 1-{{0:Icon 7}}Display CO2 value2 Bytes9.8 parts/million (ppm)CWTU
39Page 1-{{0:Icon 7}}Display air flow value2 Bytes9.9 air flow (m³/h)CWTU
39Page 1-{{0:Icon 7}}Display concentration value2 Bytes9.30 concentration (µg/m³)CWTU
39Page 1-{{0:Icon 7}}Display 4byte unsigned value4 Bytes12.1 counter pulses (unsigned)CWTU
39Page 1-{{0:Icon 7}}Display 4byte float value4 BytesDPT.14CWTU
39Page 1-{{0:Icon 7}}Display text14 Bytes16.1 Character String (ISO 8859-1)CW
39Page 1-{{0:Icon 7}}Display 1bit value1 Bit1.1 switchCWTU
40Page 1-{{0:Icon 7}}Slat position1 Byte5.1 percentage (0..100%)CT
40Page 1-{{0:Icon 7}}Dimming4 Bit3.7 dimming controlCWT
40Page 1-{{0:Icon 7}}Color temperature value2 Bytes7.600 absolute colour temperature (K)CT
40Page 1-{{0:Icon 7}}Warm white brightness1 Byte5.1 percentage (0..100%)CT
41Page 1-{{0:Icon 7}}Status blind position1 Byte5.1 percentage (0..100%)CWTU
41Page 1-{{0:Icon 7}}Status curtain position1 Byte5.1 percentage (0..100%)CWTU
41Page 1-{{0:Icon 7}}Status dim value1 Byte5.1 percentage (0..100%)CWTU
41Page 1-{{0:Icon 7}}Cool white brightness, status1 Byte5.1 percentage (0..100%)CWTU
42Page 1-{{0:Icon 7}}Status slat position1 Byte5.1 percentage (0..100%)CWTU
42Page 1-{{0:Icon 7}}Status color temperature value2 Bytes7.600 absolute colour temperature (K)CWTU
42Page 1-{{0:Icon 7}}Warm white brightness, status1 Byte5.1 percentage (0..100%)CWTU
43Page 1-{{0:Icon 8}}Send 2byte unsigned value2 Bytes7.1 pulsesCT
43Page 1-{{0:Icon 8}}Switching1 Bit1.1 switchCT
43Page 1-{{0:Icon 8}}Send 1bit value1 Bit1.1 switchCT
43Page 1-{{0:Icon 8}}Send 2bit value2 Bit2.1 switch controlCT
43Page 1-{{0:Icon 8}}Send 4bit value4 Bit3.7 dimming controlCT
43Page 1-{{0:Icon 8}}Send 1byte unsigned value1 Byte5.10 counter pulses (0..255)CT
43Page 1-{{0:Icon 8}}Send 1byte percent value1 Byte5.1 percentage (0..100%)CT
43Page 1-{{0:Icon 8}}Send 2byte signed value2 Bytes8.1 pulses differenceCT
43Page 1-{{0:Icon 8}}Open / Close1 Bit1.9 open/closeCWT
43Page 1-{{0:Icon 8}}Up / Down1 Bit1.8 up/downCWT
43Page 1-{{0:Icon 8}}Recall / Save scene1 Byte18.1 scene controlCWT
43Page 1-{{0:Icon 8}}Recall / Save scene1 Byte18.1 scene controlCT
43Page 1-{{0:Icon 8}}Send 4byte unsigned value4 Bytes12.1 counter pulses (unsigned)CT
43Page 1-{{0:Icon 8}}Send 4byte float value4 BytesDPT.14CT
43Page 1-{{0:Icon 8}}Bell function1 Bit1.1 switchCT
44Page 1-{{0:Icon 8}}Send 2byte signed value, long2 Bytes8.1 pulses differenceCT
44Page 1-{{0:Icon 8}}Dim value1 Byte5.1 percentage (0..100%)CT
44Page 1-{{0:Icon 8}}Send 1bit value, long1 Bit1.1 switchCT
44Page 1-{{0:Icon 8}}Send 2bit value, long2 Bit2.1 switch controlCT
44Page 1-{{0:Icon 8}}Send 4bit value, long4 Bit3.7 dimming controlCT
44Page 1-{{0:Icon 8}}Send 1byte unsigned value, long1 Byte5.10 counter pulses (0..255)CT
44Page 1-{{0:Icon 8}}Send 1byte percent value, long1 Byte5.1 percentage (0..100%)CT
44Page 1-{{0:Icon 8}}Send 2byte unsigned value, long2 Bytes7.1 pulsesCT
44Page 1-{{0:Icon 8}}Stop1 Bit1.7 stepCT
44Page 1-{{0:Icon 8}}Stop / Slat adj.1 Bit1.7 stepCT
44Page 1-{{0:Icon 8}}Cool white brightness1 Byte5.1 percentage (0..100%)CT
44Page 1-{{0:Icon 8}}Send 4byte unsigned value, long4 Bytes12.1 counter pulses (unsigned)CT
44Page 1-{{0:Icon 8}}Send 4byte float value, long4 BytesDPT.14CT
45Page 1-{{0:Icon 8}}Status switching1 Bit1.1 switchCWTU
45Page 1-{{0:Icon 8}}Blind position1 Byte5.1 percentage (0..100%)CT
45Page 1-{{0:Icon 8}}Curtain position1 Byte5.1 percentage (0..100%)CT
45Page 1-{{0:Icon 8}}Display 1byte unsigned value1 Byte5.10 counter pulses (0..255)CWTU
45Page 1-{{0:Icon 8}}Display 1byte percentage value1 Byte5.1 percentage (0..100%)CWTU
45Page 1-{{0:Icon 8}}Display 2byte unsigned value2 Bytes7.1 pulsesCWTU
45Page 1-{{0:Icon 8}}Display 2byte signed value2 Bytes8.1 pulses differenceCWTU
45Page 1-{{0:Icon 8}}Display 2byte float value2 BytesDPT.9CWTU
45Page 1-{{0:Icon 8}}Display temperature value2 Bytes9.1 temperature (°C)CWTU
45Page 1-{{0:Icon 8}}Display pressure value2 Bytes9.6 pressure (Pa)CWTU
45Page 1-{{0:Icon 8}}Display humidity value2 Bytes9.7 humidity (%)CWTU
45Page 1-{{0:Icon 8}}Display CO2 value2 Bytes9.8 parts/million (ppm)CWTU
45Page 1-{{0:Icon 8}}Display air flow value2 Bytes9.9 air flow (m³/h)CWTU
45Page 1-{{0:Icon 8}}Display concentration value2 Bytes9.30 concentration (µg/m³)CWTU
45Page 1-{{0:Icon 8}}Display 4byte unsigned value4 Bytes12.1 counter pulses (unsigned)CWTU
45Page 1-{{0:Icon 8}}Display 4byte float value4 BytesDPT.14CWTU
45Page 1-{{0:Icon 8}}Display text14 Bytes16.1 Character String (ISO 8859-1)CW
45Page 1-{{0:Icon 8}}Display 1bit value1 Bit1.1 switchCWTU
46Page 1-{{0:Icon 8}}Slat position1 Byte5.1 percentage (0..100%)CT
46Page 1-{{0:Icon 8}}Dimming4 Bit3.7 dimming controlCWT
46Page 1-{{0:Icon 8}}Color temperature value2 Bytes7.600 absolute colour temperature (K)CT
46Page 1-{{0:Icon 8}}Warm white brightness1 Byte5.1 percentage (0..100%)CT
47Page 1-{{0:Icon 8}}Status blind position1 Byte5.1 percentage (0..100%)CWTU
47Page 1-{{0:Icon 8}}Status curtain position1 Byte5.1 percentage (0..100%)CWTU
47Page 1-{{0:Icon 8}}Status dim value1 Byte5.1 percentage (0..100%)CWTU
47Page 1-{{0:Icon 8}}Cool white brightness, status1 Byte5.1 percentage (0..100%)CWTU
48Page 1-{{0:Icon 8}}Status slat position1 Byte5.1 percentage (0..100%)CWTU
48Page 1-{{0:Icon 8}}Status color temperature value2 Bytes7.600 absolute colour temperature (K)CWTU
48Page 1-{{0:Icon 8}}Warm white brightness, status1 Byte5.1 percentage (0..100%)CWTU
49Page 1-{{0}}Lock1 Bit1.3 enableCW
50Page 2-{{0:Icon 1}}Switching1 Bit1.1 switchCT
50Page 2-{{0:Icon 1}}Send 1bit value1 Bit1.1 switchCT
50Page 2-{{0:Icon 1}}Send 2bit value2 Bit2.1 switch controlCT
50Page 2-{{0:Icon 1}}Send 4bit value4 Bit3.7 dimming controlCT
50Page 2-{{0:Icon 1}}Send 1byte unsigned value1 Byte5.10 counter pulses (0..255)CT
50Page 2-{{0:Icon 1}}Send 1byte percent value1 Byte5.1 percentage (0..100%)CT
50Page 2-{{0:Icon 1}}Send 2byte unsigned value2 Bytes7.1 pulsesCT
50Page 2-{{0:Icon 1}}Send 2byte signed value2 Bytes8.1 pulses differenceCT
50Page 2-{{0:Icon 1}}Send 4byte unsigned value4 Bytes12.1 counter pulses (unsigned)CT
50Page 2-{{0:Icon 1}}Send 4byte float value4 BytesDPT.14CT
50Page 2-{{0:Icon 1}}Open / Close1 Bit1.9 open/closeCWT
50Page 2-{{0:Icon 1}}Up / Down1 Bit1.8 up/downCWT
50Page 2-{{0:Icon 1}}Recall / Save scene1 Byte18.1 scene controlCT
50Page 2-{{0:Icon 1}}Recall / Save scene1 Byte18.1 scene controlCWT
50Page 2-{{0:Icon 1}}Bell function1 Bit1.1 switchCT
51Page 2-{{0:Icon 1}}Dim value1 Byte5.1 percentage (0..100%)CT
51Page 2-{{0:Icon 1}}Cool white brightness1 Byte5.1 percentage (0..100%)CT
51Page 2-{{0:Icon 1}}Send 1bit value, long1 Bit1.1 switchCT
51Page 2-{{0:Icon 1}}Send 2bit value, long2 Bit2.1 switch controlCT
51Page 2-{{0:Icon 1}}Send 4bit value, long4 Bit3.7 dimming controlCT
51Page 2-{{0:Icon 1}}Send 1byte unsigned value, long1 Byte5.10 counter pulses (0..255)CT
51Page 2-{{0:Icon 1}}Send 1byte percent value, long1 Byte5.1 percentage (0..100%)CT
51Page 2-{{0:Icon 1}}Send 2byte unsigned value, long2 Bytes7.1 pulsesCT
51Page 2-{{0:Icon 1}}Send 2byte signed value, long2 Bytes8.1 pulses differenceCT
51Page 2-{{0:Icon 1}}Send 4byte unsigned value, long4 Bytes12.1 counter pulses (unsigned)CT
51Page 2-{{0:Icon 1}}Send 4byte float value, long4 BytesDPT.14CT
51Page 2-{{0:Icon 1}}Stop1 Bit1.7 stepCT
51Page 2-{{0:Icon 1}}Stop / Slat adj.1 Bit1.7 stepCT
52Page 2-{{0:Icon 1}}Status switching1 Bit1.1 switchCWTU
52Page 2-{{0:Icon 1}}Curtain position1 Byte5.1 percentage (0..100%)CT
52Page 2-{{0:Icon 1}}Blind position1 Byte5.1 percentage (0..100%)CT
52Page 2-{{0:Icon 1}}Display 1bit value1 Bit1.1 switchCWTU
52Page 2-{{0:Icon 1}}Display 1byte unsigned value1 Byte5.10 counter pulses (0..255)CWTU
52Page 2-{{0:Icon 1}}Display 1byte percentage value1 Byte5.1 percentage (0..100%)CWTU
52Page 2-{{0:Icon 1}}Display 2byte unsigned value2 Bytes7.1 pulsesCWTU
52Page 2-{{0:Icon 1}}Display 2byte signed value2 Bytes8.1 pulses differenceCWTU
52Page 2-{{0:Icon 1}}Display 2byte float value2 BytesDPT.9CWTU
52Page 2-{{0:Icon 1}}Display temperature value2 Bytes9.1 temperature (°C)CWTU
52Page 2-{{0:Icon 1}}Display pressure value2 Bytes9.6 pressure (Pa)CWTU
52Page 2-{{0:Icon 1}}Display humidity value2 Bytes9.7 humidity (%)CWTU
52Page 2-{{0:Icon 1}}Display CO2 value2 Bytes9.8 parts/million (ppm)CWTU
52Page 2-{{0:Icon 1}}Display air flow value2 Bytes9.9 air flow (m³/h)CWTU
52Page 2-{{0:Icon 1}}Display concentration value2 Bytes9.30 concentration (µg/m³)CWTU
52Page 2-{{0:Icon 1}}Display 4byte unsigned value4 Bytes12.1 counter pulses (unsigned)CWTU
52Page 2-{{0:Icon 1}}Display 4byte float value4 BytesDPT.14CWTU
52Page 2-{{0:Icon 1}}Display text14 Bytes16.1 Character String (ISO 8859-1)CW
53Page 2-{{0:Icon 1}}Dimming4 Bit3.7 dimming controlCWT
53Page 2-{{0:Icon 1}}Color temperature value2 Bytes7.600 absolute colour temperature (K)CT
53Page 2-{{0:Icon 1}}Warm white brightness1 Byte5.1 percentage (0..100%)CT
53Page 2-{{0:Icon 1}}Slat position1 Byte5.1 percentage (0..100%)CT
54Page 2-{{0:Icon 1}}Status dim value1 Byte5.1 percentage (0..100%)CWTU
54Page 2-{{0:Icon 1}}Cool white brightness, status1 Byte5.1 percentage (0..100%)CWTU
54Page 2-{{0:Icon 1}}Status curtain position1 Byte5.1 percentage (0..100%)CWTU
54Page 2-{{0:Icon 1}}Status blind position1 Byte5.1 percentage (0..100%)CWTU
55Page 2-{{0:Icon 1}}Status color temperature value2 Bytes7.600 absolute colour temperature (K)CWTU
55Page 2-{{0:Icon 1}}Warm white brightness, status1 Byte5.1 percentage (0..100%)CWTU
55Page 2-{{0:Icon 1}}Status slat position1 Byte5.1 percentage (0..100%)CWTU
56Page 2-{{0:Icon 2}}Switching1 Bit1.1 switchCT
56Page 2-{{0:Icon 2}}Send 1bit value1 Bit1.1 switchCT
56Page 2-{{0:Icon 2}}Send 2bit value2 Bit2.1 switch controlCT
56Page 2-{{0:Icon 2}}Send 4bit value4 Bit3.7 dimming controlCT
56Page 2-{{0:Icon 2}}Send 1byte unsigned value1 Byte5.10 counter pulses (0..255)CT
56Page 2-{{0:Icon 2}}Send 1byte percent value1 Byte5.1 percentage (0..100%)CT
56Page 2-{{0:Icon 2}}Send 2byte unsigned value2 Bytes7.1 pulsesCT
56Page 2-{{0:Icon 2}}Send 2byte signed value2 Bytes8.1 pulses differenceCT
56Page 2-{{0:Icon 2}}Send 4byte unsigned value4 Bytes12.1 counter pulses (unsigned)CT
56Page 2-{{0:Icon 2}}Send 4byte float value4 BytesDPT.14CT
56Page 2-{{0:Icon 2}}Open / Close1 Bit1.9 open/closeCWT
56Page 2-{{0:Icon 2}}Up / Down1 Bit1.8 up/downCWT
56Page 2-{{0:Icon 2}}Recall / Save scene1 Byte18.1 scene controlCT
56Page 2-{{0:Icon 2}}Recall / Save scene1 Byte18.1 scene controlCWT
56Page 2-{{0:Icon 2}}Bell function1 Bit1.1 switchCT
57Page 2-{{0:Icon 2}}Dim value1 Byte5.1 percentage (0..100%)CT
57Page 2-{{0:Icon 2}}Cool white brightness1 Byte5.1 percentage (0..100%)CT
57Page 2-{{0:Icon 2}}Send 1bit value, long1 Bit1.1 switchCT
57Page 2-{{0:Icon 2}}Send 2bit value, long2 Bit2.1 switch controlCT
57Page 2-{{0:Icon 2}}Send 4bit value, long4 Bit3.7 dimming controlCT
57Page 2-{{0:Icon 2}}Send 1byte unsigned value, long1 Byte5.10 counter pulses (0..255)CT
57Page 2-{{0:Icon 2}}Send 1byte percent value, long1 Byte5.1 percentage (0..100%)CT
57Page 2-{{0:Icon 2}}Send 2byte unsigned value, long2 Bytes7.1 pulsesCT
57Page 2-{{0:Icon 2}}Send 2byte signed value, long2 Bytes8.1 pulses differenceCT
57Page 2-{{0:Icon 2}}Send 4byte unsigned value4 Bytes12.1 counter pulses (unsigned)CT
57Page 2-{{0:Icon 2}}Send 4byte float value, long4 BytesDPT.14CT
57Page 2-{{0:Icon 2}}Stop1 Bit1.7 stepCT
57Page 2-{{0:Icon 2}}Stop / Slat adj.1 Bit1.7 stepCT
58Page 2-{{0:Icon 2}}Status switching1 Bit1.1 switchCWTU
58Page 2-{{0:Icon 2}}Curtain position1 Byte5.1 percentage (0..100%)CT
58Page 2-{{0:Icon 2}}Blind position1 Byte5.1 percentage (0..100%)CT
58Page 2-{{0:Icon 2}}Display 1bit value1 Bit1.1 switchCWTU
58Page 2-{{0:Icon 2}}Display 1byte unsigned value1 Byte5.10 counter pulses (0..255)CWTU
58Page 2-{{0:Icon 2}}Display 1byte percentage value1 Byte5.1 percentage (0..100%)CWTU
58Page 2-{{0:Icon 2}}Display 2byte unsigned value2 Bytes7.1 pulsesCWTU
58Page 2-{{0:Icon 2}}Display 2byte signed value2 Bytes8.1 pulses differenceCWTU
58Page 2-{{0:Icon 2}}Display 2byte float value2 BytesDPT.9CWTU
58Page 2-{{0:Icon 2}}Display temperature value2 Bytes9.1 temperature (°C)CWTU
58Page 2-{{0:Icon 2}}Display pressure value2 Bytes9.6 pressure (Pa)CWTU
58Page 2-{{0:Icon 2}}Display humidity value2 Bytes9.7 humidity (%)CWTU
58Page 2-{{0:Icon 2}}Display CO2 value2 Bytes9.8 parts/million (ppm)CWTU
58Page 2-{{0:Icon 2}}Display air flow value2 Bytes9.9 air flow (m³/h)CWTU
58Page 2-{{0:Icon 2}}Display concentration value2 Bytes9.30 concentration (µg/m³)CWTU
58Page 2-{{0:Icon 2}}Display 4byte unsigned value4 Bytes12.1 counter pulses (unsigned)CWTU
58Page 2-{{0:Icon 2}}Display 4byte float value4 BytesDPT.14CWTU
58Page 2-{{0:Icon 2}}Display text14 Bytes16.1 Character String (ISO 8859-1)CW
59Page 2-{{0:Icon 2}}Dimming4 Bit3.7 dimming controlCWT
59Page 2-{{0:Icon 2}}Color temperature value2 Bytes7.600 absolute colour temperature (K)CT
59Page 2-{{0:Icon 2}}Warm white brightness1 Byte5.1 percentage (0..100%)CT
59Page 2-{{0:Icon 2}}Slat position1 Byte5.1 percentage (0..100%)CT
60Page 2-{{0:Icon 2}}Status dim value1 Byte5.1 percentage (0..100%)CWTU
60Page 2-{{0:Icon 2}}Cool white brightness, status1 Byte5.1 percentage (0..100%)CWTU
60Page 2-{{0:Icon 2}}Status curtain position1 Byte5.1 percentage (0..100%)CWTU
60Page 2-{{0:Icon 2}}Status blind position1 Byte5.1 percentage (0..100%)CWTU
61Page 2-{{0:Icon 2}}Status color temperature value2 Bytes7.600 absolute colour temperature (K)CWTU
61Page 2-{{0:Icon 2}}Warm white brightness, status1 Byte5.1 percentage (0..100%)CWTU
61Page 2-{{0:Icon 2}}Status slat position1 Byte5.1 percentage (0..100%)CWTU
62Page 2-{{0:Icon 3}}Switching1 Bit1.1 switchCT
62Page 2-{{0:Icon 3}}Send 1bit value1 Bit1.1 switchCT
62Page 2-{{0:Icon 3}}Send 2bit value2 Bit2.1 switch controlCT
62Page 2-{{0:Icon 3}}Send 4bit value4 Bit3.7 dimming controlCT
62Page 2-{{0:Icon 3}}Send 1byte unsigned value1 Byte5.10 counter pulses (0..255)CT
62Page 2-{{0:Icon 3}}Send 1byte percent value1 Byte5.1 percentage (0..100%)CT
62Page 2-{{0:Icon 3}}Send 2byte unsigned value2 Bytes7.1 pulsesCT
62Page 2-{{0:Icon 3}}Send 2byte signed value2 Bytes8.1 pulses differenceCT
62Page 2-{{0:Icon 3}}Send 4byte unsigned value4 Bytes12.1 counter pulses (unsigned)CT
62Page 2-{{0:Icon 3}}Send 4byte float value4 BytesDPT.14CT
62Page 2-{{0:Icon 3}}Open / Close1 Bit1.9 open/closeCWT
62Page 2-{{0:Icon 3}}Up / Down1 Bit1.8 up/downCWT
62Page 2-{{0:Icon 3}}Recall / Save scene1 Byte18.1 scene controlCT
62Page 2-{{0:Icon 3}}Recall / Save scene1 Byte18.1 scene controlCWT
62Page 2-{{0:Icon 3}}Bell function1 Bit1.1 switchCT
63Page 2-{{0:Icon 3}}Dim value1 Byte5.1 percentage (0..100%)CT
63Page 2-{{0:Icon 3}}Cool white brightness1 Byte5.1 percentage (0..100%)CT
63Page 2-{{0:Icon 3}}Send 1bit value, long1 Bit1.1 switchCT
63Page 2-{{0:Icon 3}}Send 2bit value, long2 Bit2.1 switch controlCT
63Page 2-{{0:Icon 3}}Send 4bit value, long4 Bit3.7 dimming controlCT
63Page 2-{{0:Icon 3}}Send 1byte unsigned value, long1 Byte5.10 counter pulses (0..255)CT
63Page 2-{{0:Icon 3}}Send 1byte percent value, long1 Byte5.1 percentage (0..100%)CT
63Page 2-{{0:Icon 3}}Send 2byte unsigned value, long2 Bytes7.1 pulsesCT
63Page 2-{{0:Icon 3}}Send 2byte signed value, long2 Bytes8.1 pulses differenceCT
63Page 2-{{0:Icon 3}}Send 4byte unsigned value, long4 Bytes12.1 counter pulses (unsigned)CT
63Page 2-{{0:Icon 3}}Send 4byte float value, long4 BytesDPT.14CT
63Page 2-{{0:Icon 3}}Stop1 Bit1.7 stepCT
63Page 2-{{0:Icon 3}}Stop / Slat adj.1 Bit1.7 stepCT
64Page 2-{{0:Icon 3}}Status switching1 Bit1.1 switchCWTU
64Page 2-{{0:Icon 3}}Curtain position1 Byte5.1 percentage (0..100%)CT
64Page 2-{{0:Icon 3}}Blind position1 Byte5.1 percentage (0..100%)CT
64Page 2-{{0:Icon 3}}Display 1bit value1 Bit1.1 switchCWTU
64Page 2-{{0:Icon 3}}Display 1byte unsigned value1 Byte5.10 counter pulses (0..255)CWTU
64Page 2-{{0:Icon 3}}Display 1byte percentage value1 Byte5.1 percentage (0..100%)CWTU
64Page 2-{{0:Icon 3}}Display 2byte unsigned value2 Bytes7.1 pulsesCWTU
64Page 2-{{0:Icon 3}}Display 2byte signed value2 Bytes8.1 pulses differenceCWTU
64Page 2-{{0:Icon 3}}Display 2byte float value2 BytesDPT.9CWTU
64Page 2-{{0:Icon 3}}Display temperature value2 Bytes9.1 temperature (°C)CWTU
64Page 2-{{0:Icon 3}}Display pressure value2 Bytes9.6 pressure (Pa)CWTU
64Page 2-{{0:Icon 3}}Display humidity value2 Bytes9.7 humidity (%)CWTU
64Page 2-{{0:Icon 3}}Display CO2 value2 Bytes9.8 parts/million (ppm)CWTU
64Page 2-{{0:Icon 3}}Display air flow value2 Bytes9.9 air flow (m³/h)CWTU
64Page 2-{{0:Icon 3}}Display concentration value2 Bytes9.30 concentration (µg/m³)CWTU
64Page 2-{{0:Icon 3}}Display 4byte unsigned value4 Bytes12.1 counter pulses (unsigned)CWTU
64Page 2-{{0:Icon 3}}Display 4byte float value4 BytesDPT.14CWTU
64Page 2-{{0:Icon 3}}Display text14 Bytes16.1 Character String (ISO 8859-1)CW
65Page 2-{{0:Icon 3}}Dimming4 Bit3.7 dimming controlCWT
65Page 2-{{0:Icon 3}}Color temperature value2 Bytes7.600 absolute colour temperature (K)CT
65Page 2-{{0:Icon 3}}Warm white brightness1 Byte5.1 percentage (0..100%)CT
65Page 2-{{0:Icon 3}}Slat position1 Byte5.1 percentage (0..100%)CT
66Page 2-{{0:Icon 3}}Status dim value1 Byte5.1 percentage (0..100%)CWTU
66Page 2-{{0:Icon 3}}Cool white brightness, status1 Byte5.1 percentage (0..100%)CWTU
66Page 2-{{0:Icon 3}}Status curtain position1 Byte5.1 percentage (0..100%)CWTU
66Page 2-{{0:Icon 3}}Status blind position1 Byte5.1 percentage (0..100%)CWTU
67Page 2-{{0:Icon 3}}Status color temperature value2 Bytes7.600 absolute colour temperature (K)CWTU
67Page 2-{{0:Icon 3}}Warm white brightness, status1 Byte5.1 percentage (0..100%)CWTU
67Page 2-{{0:Icon 3}}Status slat position1 Byte5.1 percentage (0..100%)CWTU
68Page 2-{{0:Icon 4}}Switching1 Bit1.1 switchCT
68Page 2-{{0:Icon 4}}Send 1bit value1 Bit1.1 switchCT
68Page 2-{{0:Icon 4}}Send 2bit value2 Bit2.1 switch controlCT
68Page 2-{{0:Icon 4}}Send 4bit value4 Bit3.7 dimming controlCT
68Page 2-{{0:Icon 4}}Send 1byte unsigned value1 Byte5.10 counter pulses (0..255)CT
68Page 2-{{0:Icon 4}}Send 1byte percent value1 Byte5.1 percentage (0..100%)CT
68Page 2-{{0:Icon 4}}Send 2byte unsigned value2 Bytes7.1 pulsesCT
68Page 2-{{0:Icon 4}}Send 2byte signed value2 Bytes8.1 pulses differenceCT
68Page 2-{{0:Icon 4}}Send 4byte unsigned value4 Bytes12.1 counter pulses (unsigned)CT
68Page 2-{{0:Icon 4}}Send 4byte float value4 BytesDPT.14CT
68Page 2-{{0:Icon 4}}Open / Close1 Bit1.9 open/closeCWT
68Page 2-{{0:Icon 4}}Up / Down1 Bit1.8 up/downCWT
68Page 2-{{0:Icon 4}}Recall / Save scene1 Byte18.1 scene controlCT
68Page 2-{{0:Icon 4}}Recall / Save scene1 Byte18.1 scene controlCWT
68Page 2-{{0:Icon 4}}Bell function1 Bit1.1 switchCT
69Page 2-{{0:Icon 4}}Dim value1 Byte5.1 percentage (0..100%)CT
69Page 2-{{0:Icon 4}}Cool white brightness1 Byte5.1 percentage (0..100%)CT
69Page 2-{{0:Icon 4}}Send 1bit value, long1 Bit1.1 switchCT
69Page 2-{{0:Icon 4}}Send 2bit value, long2 Bit2.1 switch controlCT
69Page 2-{{0:Icon 4}}Send 4bit value, long4 Bit3.7 dimming controlCT
69Page 2-{{0:Icon 4}}Send 1byte unsigned value, long1 Byte5.10 counter pulses (0..255)CT
69Page 2-{{0:Icon 4}}Send 1byte percent value, long1 Byte5.1 percentage (0..100%)CT
69Page 2-{{0:Icon 4}}Send 2byte unsigned value, long2 Bytes7.1 pulsesCT
69Page 2-{{0:Icon 4}}Send 2byte signed value, long2 Bytes8.1 pulses differenceCT
69Page 2-{{0:Icon 4}}Send 4byte unsigned value, long4 Bytes12.1 counter pulses (unsigned)CT
69Page 2-{{0:Icon 4}}Send 4byte float value, long4 BytesDPT.14CT
69Page 2-{{0:Icon 4}}Stop1 Bit1.7 stepCT
69Page 2-{{0:Icon 4}}Stop / Slat adj.1 Bit1.7 stepCT
70Page 2-{{0:Icon 4}}Status switching1 Bit1.1 switchCWTU
70Page 2-{{0:Icon 4}}Curtain position1 Byte5.1 percentage (0..100%)CT
70Page 2-{{0:Icon 4}}Blind position1 Byte5.1 percentage (0..100%)CT
70Page 2-{{0:Icon 4}}Display 1bit value1 Bit1.1 switchCWTU
70Page 2-{{0:Icon 4}}Display 1byte unsigned value1 Byte5.10 counter pulses (0..255)CWTU
70Page 2-{{0:Icon 4}}Display 1byte percentage value1 Byte5.1 percentage (0..100%)CWTU
70Page 2-{{0:Icon 4}}Display 2byte unsigned value2 Bytes7.1 pulsesCWTU
70Page 2-{{0:Icon 4}}Display 2byte signed value2 Bytes8.1 pulses differenceCWTU
70Page 2-{{0:Icon 4}}Display 2byte float value2 BytesDPT.9CWTU
70Page 2-{{0:Icon 4}}Display temperature value2 Bytes9.1 temperature (°C)CWTU
70Page 2-{{0:Icon 4}}Display pressure value2 Bytes9.6 pressure (Pa)CWTU
70Page 2-{{0:Icon 4}}Display humidity value2 Bytes9.7 humidity (%)CWTU
70Page 2-{{0:Icon 4}}Display CO2 value2 Bytes9.8 parts/million (ppm)CWTU
70Page 2-{{0:Icon 4}}Display air flow value2 Bytes9.9 air flow (m³/h)CWTU
70Page 2-{{0:Icon 4}}Display concentration value2 Bytes9.30 concentration (µg/m³)CWTU
70Page 2-{{0:Icon 4}}Display 4byte unsigned value4 Bytes12.1 counter pulses (unsigned)CWTU
70Page 2-{{0:Icon 4}}Display 4byte float value4 BytesDPT.14CWTU
70Page 2-{{0:Icon 4}}Display text14 Bytes16.1 Character String (ISO 8859-1)CW
71Page 2-{{0:Icon 4}}Dimming4 Bit3.7 dimming controlCWT
71Page 2-{{0:Icon 4}}Color temperature value2 Bytes7.600 absolute colour temperature (K)CT
71Page 2-{{0:Icon 4}}Warm white brightness1 Byte5.1 percentage (0..100%)CT
71Page 2-{{0:Icon 4}}Slat position1 Byte5.1 percentage (0..100%)CT
72Page 2-{{0:Icon 4}}Status dim value1 Byte5.1 percentage (0..100%)CWTU
72Page 2-{{0:Icon 4}}Cool white brightness, status1 Byte5.1 percentage (0..100%)CWTU
72Page 2-{{0:Icon 4}}Status curtain position1 Byte5.1 percentage (0..100%)CWTU
72Page 2-{{0:Icon 4}}Status blind position1 Byte5.1 percentage (0..100%)CWTU
73Page 2-{{0:Icon 4}}Status color temperature value2 Bytes7.600 absolute colour temperature (K)CWTU
73Page 2-{{0:Icon 4}}Warm white brightness, status1 Byte5.1 percentage (0..100%)CWTU
73Page 2-{{0:Icon 4}}Status slat position1 Byte5.1 percentage (0..100%)CWTU
74Page 2-{{0:Icon 5}}Switching1 Bit1.1 switchCT
74Page 2-{{0:Icon 5}}Send 1bit value1 Bit1.1 switchCT
74Page 2-{{0:Icon 5}}Send 2bit value2 Bit2.1 switch controlCT
74Page 2-{{0:Icon 5}}Send 4bit value4 Bit3.7 dimming controlCT
74Page 2-{{0:Icon 5}}Send 1byte unsigned value1 Byte5.10 counter pulses (0..255)CT
74Page 2-{{0:Icon 5}}Send 1byte percent value1 Byte5.1 percentage (0..100%)CT
74Page 2-{{0:Icon 5}}Send 2byte unsigned value2 Bytes7.1 pulsesCT
74Page 2-{{0:Icon 5}}Send 2byte signed value2 Bytes8.1 pulses differenceCT
74Page 2-{{0:Icon 5}}Send 4byte unsigned value4 Bytes12.1 counter pulses (unsigned)CT
74Page 2-{{0:Icon 5}}Send 4byte float value4 BytesDPT.14CT
74Page 2-{{0:Icon 5}}Open / Close1 Bit1.9 open/closeCWT
74Page 2-{{0:Icon 5}}Up / Down1 Bit1.8 up/downCWT
74Page 2-{{0:Icon 5}}Recall / Save scene1 Byte18.1 scene controlCT
74Page 2-{{0:Icon 5}}Recall / Save scene1 Byte18.1 scene controlCWT
74Page 2-{{0:Icon 5}}Bell function1 Bit1.1 switchCT
75Page 2-{{0:Icon 5}}Dim value1 Byte5.1 percentage (0..100%)CT
75Page 2-{{0:Icon 5}}Cool white brightness1 Byte5.1 percentage (0..100%)CT
75Page 2-{{0:Icon 5}}Send 1bit value, long1 Bit1.1 switchCT
75Page 2-{{0:Icon 5}}Send 2bit value, long2 Bit2.1 switch controlCT
75Page 2-{{0:Icon 5}}Send 4bit value, long4 Bit3.7 dimming controlCT
75Page 2-{{0:Icon 5}}Send 1byte unsigned value, long1 Byte5.10 counter pulses (0..255)CT
75Page 2-{{0:Icon 5}}Send 1byte percent value, long1 Byte5.1 percentage (0..100%)CT
75Page 2-{{0:Icon 5}}Send 2byte unsigned value, long2 Bytes7.1 pulsesCT
75Page 2-{{0:Icon 5}}Send 2byte signed value, long2 Bytes8.1 pulses differenceCT
75Page 2-{{0:Icon 5}}Send 4byte unsigned value, long4 Bytes12.1 counter pulses (unsigned)CT
75Page 2-{{0:Icon 5}}Send 4byte float value, long4 BytesDPT.14CT
75Page 2-{{0:Icon 5}}Stop1 Bit1.7 stepCT
75Page 2-{{0:Icon 5}}Stop / Slat adj.1 Bit1.7 stepCT
76Page 2-{{0:Icon 5}}Status switching1 Bit1.1 switchCWTU
76Page 2-{{0:Icon 5}}Curtain position1 Byte5.1 percentage (0..100%)CT
76Page 2-{{0:Icon 5}}Blind position1 Byte5.1 percentage (0..100%)CT
76Page 2-{{0:Icon 5}}Display 1bit value1 Bit1.1 switchCWTU
76Page 2-{{0:Icon 5}}Display 1byte unsigned value1 Byte5.10 counter pulses (0..255)CWTU
76Page 2-{{0:Icon 5}}Display 1byte percentage value1 Byte5.1 percentage (0..100%)CWTU
76Page 2-{{0:Icon 5}}Display 2byte unsigned value2 Bytes7.1 pulsesCWTU
76Page 2-{{0:Icon 5}}Display 2byte signed value2 Bytes8.1 pulses differenceCWTU
76Page 2-{{0:Icon 5}}Display 2byte float value2 BytesDPT.9CWTU
76Page 2-{{0:Icon 5}}Display temperature value2 Bytes9.1 temperature (°C)CWTU
76Page 2-{{0:Icon 5}}Display pressure value2 Bytes9.6 pressure (Pa)CWTU
76Page 2-{{0:Icon 5}}Display humidity value2 Bytes9.7 humidity (%)CWTU
76Page 2-{{0:Icon 5}}Display CO2 value2 Bytes9.8 parts/million (ppm)CWTU
76Page 2-{{0:Icon 5}}Display air flow value2 Bytes9.9 air flow (m³/h)CWTU
76Page 2-{{0:Icon 5}}Display concentration value2 Bytes9.30 concentration (µg/m³)CWTU
76Page 2-{{0:Icon 5}}Display 4byte unsigned value4 Bytes12.1 counter pulses (unsigned)CWTU
76Page 2-{{0:Icon 5}}Display 4byte float value4 BytesDPT.14CWTU
76Page 2-{{0:Icon 5}}Display text14 Bytes16.1 Character String (ISO 8859-1)CW
77Page 2-{{0:Icon 5}}Dimming4 Bit3.7 dimming controlCWT
77Page 2-{{0:Icon 5}}Color temperature value2 Bytes7.600 absolute colour temperature (K)CT
77Page 2-{{0:Icon 5}}Warm white brightness1 Byte5.1 percentage (0..100%)CT
77Page 2-{{0:Icon 5}}Slat position1 Byte5.1 percentage (0..100%)CT
78Page 2-{{0:Icon 5}}Status dim value1 Byte5.1 percentage (0..100%)CWTU
78Page 2-{{0:Icon 5}}Cool white brightness, status1 Byte5.1 percentage (0..100%)CWTU
78Page 2-{{0:Icon 5}}Status curtain position1 Byte5.1 percentage (0..100%)CWTU
78Page 2-{{0:Icon 5}}Status blind position1 Byte5.1 percentage (0..100%)CWTU
79Page 2-{{0:Icon 5}}Status color temperature value2 Bytes7.600 absolute colour temperature (K)CWTU
79Page 2-{{0:Icon 5}}Warm white brightness, status1 Byte5.1 percentage (0..100%)CWTU
79Page 2-{{0:Icon 5}}Status slat position1 Byte5.1 percentage (0..100%)CWTU
80Page 2-{{0:Icon 6}}Switching1 Bit1.1 switchCT
80Page 2-{{0:Icon 6}}Send 1bit value1 Bit1.1 switchCT
80Page 2-{{0:Icon 6}}Send 2bit value2 Bit2.1 switch controlCT
80Page 2-{{0:Icon 6}}Send 4bit value4 Bit3.7 dimming controlCT
80Page 2-{{0:Icon 6}}Send 1byte unsigned value1 Byte5.10 counter pulses (0..255)CT
80Page 2-{{0:Icon 6}}Send 1byte percent value1 Byte5.1 percentage (0..100%)CT
80Page 2-{{0:Icon 6}}Send 2byte unsigned value2 Bytes7.1 pulsesCT
80Page 2-{{0:Icon 6}}Send 2byte signed value2 Bytes8.1 pulses differenceCT
80Page 2-{{0:Icon 6}}Send 4byte unsigned value4 Bytes12.1 counter pulses (unsigned)CT
80Page 2-{{0:Icon 6}}Send 4byte float value4 BytesDPT.14CT
80Page 2-{{0:Icon 6}}Open / Close1 Bit1.9 open/closeCWT
80Page 2-{{0:Icon 6}}Up / Down1 Bit1.8 up/downCWT
80Page 2-{{0:Icon 6}}Recall / Save scene1 Byte18.1 scene controlCT
80Page 2-{{0:Icon 6}}Recall / Save scene1 Byte18.1 scene controlCWT
80Page 2-{{0:Icon 6}}Bell function1 Bit1.1 switchCT
81Page 2-{{0:Icon 6}}Dim value1 Byte5.1 percentage (0..100%)CT
81Page 2-{{0:Icon 6}}Cool white brightness1 Byte5.1 percentage (0..100%)CT
81Page 2-{{0:Icon 6}}Send 1bit value, long1 Bit1.1 switchCT
81Page 2-{{0:Icon 6}}Send 2bit value, long2 Bit2.1 switch controlCT
81Page 2-{{0:Icon 6}}Send 4bit value, long4 Bit3.7 dimming controlCT
81Page 2-{{0:Icon 6}}Send 1byte unsigned value, long1 Byte5.10 counter pulses (0..255)CT
81Page 2-{{0:Icon 6}}Send 1byte percent value, long1 Byte5.1 percentage (0..100%)CT
81Page 2-{{0:Icon 6}}Send 2byte unsigned value, long2 Bytes7.1 pulsesCT
81Page 2-{{0:Icon 6}}Send 2byte signed value, long2 Bytes8.1 pulses differenceCT
81Page 2-{{0:Icon 6}}Send 4byte unsigned value, long4 Bytes12.1 counter pulses (unsigned)CT
81Page 2-{{0:Icon 6}}Send 4byte float value, long4 BytesDPT.14CT
81Page 2-{{0:Icon 6}}Stop1 Bit1.7 stepCT
81Page 2-{{0:Icon 6}}Stop / Slat adj.1 Bit1.7 stepCT
82Page 2-{{0:Icon 6}}Status switching1 Bit1.1 switchCWTU
82Page 2-{{0:Icon 6}}Curtain position1 Byte5.1 percentage (0..100%)CT
82Page 2-{{0:Icon 6}}Blind position1 Byte5.1 percentage (0..100%)CT
82Page 2-{{0:Icon 6}}Display 1bit value1 Bit1.1 switchCWTU
82Page 2-{{0:Icon 6}}Display 1byte unsigned value1 Byte5.10 counter pulses (0..255)CWTU
82Page 2-{{0:Icon 6}}Display 1byte percentage value1 Byte5.1 percentage (0..100%)CWTU
82Page 2-{{0:Icon 6}}Display 2byte unsigned value2 Bytes7.1 pulsesCWTU
82Page 2-{{0:Icon 6}}Display 2byte signed value2 Bytes8.1 pulses differenceCWTU
82Page 2-{{0:Icon 6}}Display 2byte float value2 BytesDPT.9CWTU
82Page 2-{{0:Icon 6}}Display temperature value2 Bytes9.1 temperature (°C)CWTU
82Page 2-{{0:Icon 6}}Display pressure value2 Bytes9.6 pressure (Pa)CWTU
82Page 2-{{0:Icon 6}}Display humidity value2 Bytes9.7 humidity (%)CWTU
82Page 2-{{0:Icon 6}}Display CO2 value2 Bytes9.8 parts/million (ppm)CWTU
82Page 2-{{0:Icon 6}}Display air flow value2 Bytes9.9 air flow (m³/h)CWTU
82Page 2-{{0:Icon 6}}Display concentration value2 Bytes9.30 concentration (µg/m³)CWTU
82Page 2-{{0:Icon 6}}Display 4byte unsigned value4 Bytes12.1 counter pulses (unsigned)CWTU
82Page 2-{{0:Icon 6}}Display 4byte float value4 BytesDPT.14CWTU
82Page 2-{{0:Icon 6}}Display text14 Bytes16.1 Character String (ISO 8859-1)CW
83Page 2-{{0:Icon 6}}Dimming4 Bit3.7 dimming controlCWT
83Page 2-{{0:Icon 6}}Color temperature value2 Bytes7.600 absolute colour temperature (K)CT
83Page 2-{{0:Icon 6}}Warm white brightness1 Byte5.1 percentage (0..100%)CT
83Page 2-{{0:Icon 6}}Slat position1 Byte5.1 percentage (0..100%)CT
84Page 2-{{0:Icon 6}}Status dim value1 Byte5.1 percentage (0..100%)CWTU
84Page 2-{{0:Icon 6}}Cool white brightness, status1 Byte5.1 percentage (0..100%)CWTU
84Page 2-{{0:Icon 6}}Status curtain position1 Byte5.1 percentage (0..100%)CWTU
84Page 2-{{0:Icon 6}}Status blind position1 Byte5.1 percentage (0..100%)CWTU
85Page 2-{{0:Icon 6}}Status color temperature value2 Bytes7.600 absolute colour temperature (K)CWTU
85Page 2-{{0:Icon 6}}Warm white brightness, status1 Byte5.1 percentage (0..100%)CWTU
85Page 2-{{0:Icon 6}}Status slat position1 Byte5.1 percentage (0..100%)CWTU
86Page 2-{{0:Icon 7}}Switching1 Bit1.1 switchCT
86Page 2-{{0:Icon 7}}Send 1bit value1 Bit1.1 switchCT
86Page 2-{{0:Icon 7}}Send 2bit value2 Bit2.1 switch controlCT
86Page 2-{{0:Icon 7}}Send 4bit value4 Bit3.7 dimming controlCT
86Page 2-{{0:Icon 7}}Send 1byte unsigned value1 Byte5.10 counter pulses (0..255)CT
86Page 2-{{0:Icon 7}}Send 1byte percent value1 Byte5.1 percentage (0..100%)CT
86Page 2-{{0:Icon 7}}Send 2byte unsigned value2 Bytes7.1 pulsesCT
86Page 2-{{0:Icon 7}}Send 2byte signed value2 Bytes8.1 pulses differenceCT
86Page 2-{{0:Icon 7}}Send 4byte unsigned value4 Bytes12.1 counter pulses (unsigned)CT
86Page 2-{{0:Icon 7}}Send 4byte float value4 BytesDPT.14CT
86Page 2-{{0:Icon 7}}Open / Close1 Bit1.9 open/closeCWT
86Page 2-{{0:Icon 7}}Up / Down1 Bit1.8 up/downCWT
86Page 2-{{0:Icon 7}}Recall / Save scene1 Byte18.1 scene controlCT
86Page 2-{{0:Icon 7}}Recall / Save scene1 Byte18.1 scene controlCWT
86Page 2-{{0:Icon 7}}Bell function1 Bit1.1 switchCT
87Page 2-{{0:Icon 7}}Dim value1 Byte5.1 percentage (0..100%)CT
87Page 2-{{0:Icon 7}}Cool white brightness1 Byte5.1 percentage (0..100%)CT
87Page 2-{{0:Icon 7}}Send 1bit value, long1 Bit1.1 switchCT
87Page 2-{{0:Icon 7}}Send 2bit value, long2 Bit2.1 switch controlCT
87Page 2-{{0:Icon 7}}Send 4bit value, long4 Bit3.7 dimming controlCT
87Page 2-{{0:Icon 7}}Send 1byte unsigned value, long1 Byte5.10 counter pulses (0..255)CT
87Page 2-{{0:Icon 7}}Send 1byte percent value, long1 Byte5.1 percentage (0..100%)CT
87Page 2-{{0:Icon 7}}Send 2byte unsigned value, long2 Bytes7.1 pulsesCT
87Page 2-{{0:Icon 7}}Send 2byte signed value, long2 Bytes8.1 pulses differenceCT
87Page 2-{{0:Icon 7}}Send 4byte unsigned value, long4 Bytes12.1 counter pulses (unsigned)CT
87Page 2-{{0:Icon 7}}Send 4byte float value, long4 BytesDPT.14CT
87Page 2-{{0:Icon 7}}Stop1 Bit1.7 stepCT
87Page 2-{{0:Icon 7}}Stop / Slat adj.1 Bit1.7 stepCT
88Page 2-{{0:Icon 7}}Status switching1 Bit1.1 switchCWTU
88Page 2-{{0:Icon 7}}Curtain position1 Byte5.1 percentage (0..100%)CT
88Page 2-{{0:Icon 7}}Blind position1 Byte5.1 percentage (0..100%)CT
88Page 2-{{0:Icon 7}}Display 1bit value1 Bit1.1 switchCWTU
88Page 2-{{0:Icon 7}}Display 1byte unsigned value1 Byte5.10 counter pulses (0..255)CWTU
88Page 2-{{0:Icon 7}}Display 1byte percentage value1 Byte5.1 percentage (0..100%)CWTU
88Page 2-{{0:Icon 7}}Display 2byte unsigned value2 Bytes7.1 pulsesCWTU
88Page 2-{{0:Icon 7}}Display 2byte signed value2 Bytes8.1 pulses differenceCWTU
88Page 2-{{0:Icon 7}}Display 2byte float value2 BytesDPT.9CWTU
88Page 2-{{0:Icon 7}}Display temperature value2 Bytes9.1 temperature (°C)CWTU
88Page 2-{{0:Icon 7}}Display pressure value2 Bytes9.6 pressure (Pa)CWTU
88Page 2-{{0:Icon 7}}Display humidity value2 Bytes9.7 humidity (%)CWTU
88Page 2-{{0:Icon 7}}Display CO2 value2 Bytes9.8 parts/million (ppm)CWTU
88Page 2-{{0:Icon 7}}Display air flow value2 Bytes9.9 air flow (m³/h)CWTU
88Page 2-{{0:Icon 7}}Display concentration value2 Bytes9.30 concentration (µg/m³)CWTU
88Page 2-{{0:Icon 7}}Display 4byte unsigned value4 Bytes12.1 counter pulses (unsigned)CWTU
88Page 2-{{0:Icon 7}}Display 4byte float value4 BytesDPT.14CWTU
88Page 2-{{0:Icon 7}}Display text14 Bytes16.1 Character String (ISO 8859-1)CW
89Page 2-{{0:Icon 7}}Dimming4 Bit3.7 dimming controlCWT
89Page 2-{{0:Icon 7}}Color temperature value2 Bytes7.600 absolute colour temperature (K)CT
89Page 2-{{0:Icon 7}}Warm white brightness1 Byte5.1 percentage (0..100%)CT
89Page 2-{{0:Icon 7}}Slat position1 Byte5.1 percentage (0..100%)CT
90Page 2-{{0:Icon 7}}Status dim value1 Byte5.1 percentage (0..100%)CWTU
90Page 2-{{0:Icon 7}}Cool white brightness, status1 Byte5.1 percentage (0..100%)CWTU
90Page 2-{{0:Icon 7}}Status curtain position1 Byte5.1 percentage (0..100%)CWTU
90Page 2-{{0:Icon 7}}Status blind position1 Byte5.1 percentage (0..100%)CWTU
91Page 2-{{0:Icon 7}}Status color temperature value2 Bytes7.600 absolute colour temperature (K)CWTU
91Page 2-{{0:Icon 7}}Warm white brightness, status1 Byte5.1 percentage (0..100%)CWTU
91Page 2-{{0:Icon 7}}Status slat position1 Byte5.1 percentage (0..100%)CWTU
92Page 2-{{0:Icon 8}}Switching1 Bit1.1 switchCT
92Page 2-{{0:Icon 8}}Send 1bit value1 Bit1.1 switchCT
92Page 2-{{0:Icon 8}}Send 2bit value2 Bit2.1 switch controlCT
92Page 2-{{0:Icon 8}}Send 4bit value4 Bit3.7 dimming controlCT
92Page 2-{{0:Icon 8}}Send 1byte unsigned value1 Byte5.10 counter pulses (0..255)CT
92Page 2-{{0:Icon 8}}Send 1byte percent value1 Byte5.1 percentage (0..100%)CT
92Page 2-{{0:Icon 8}}Send 2byte unsigned value2 Bytes7.1 pulsesCT
92Page 2-{{0:Icon 8}}Send 2byte signed value2 Bytes8.1 pulses differenceCT
92Page 2-{{0:Icon 8}}Send 4byte unsigned value4 Bytes12.1 counter pulses (unsigned)CT
92Page 2-{{0:Icon 8}}Send 4byte float value4 BytesDPT.14CT
92Page 2-{{0:Icon 8}}Open / Close1 Bit1.9 open/closeCWT
92Page 2-{{0:Icon 8}}Up / Down1 Bit1.8 up/downCWT
92Page 2-{{0:Icon 8}}Recall / Save scene1 Byte18.1 scene controlCT
92Page 2-{{0:Icon 8}}Recall / Save scene1 Byte18.1 scene controlCWT
92Page 2-{{0:Icon 8}}Bell function1 Bit1.1 switchCT
93Page 2-{{0:Icon 8}}Dim value1 Byte5.1 percentage (0..100%)CT
93Page 2-{{0:Icon 8}}Cool white brightness1 Byte5.1 percentage (0..100%)CT
93Page 2-{{0:Icon 8}}Send 1bit value, long1 Bit1.1 switchCT
93Page 2-{{0:Icon 8}}Send 2bit value, long2 Bit2.1 switch controlCT
93Page 2-{{0:Icon 8}}Send 4bit value, long4 Bit3.7 dimming controlCT
93Page 2-{{0:Icon 8}}Send 1byte unsigned value, long1 Byte5.10 counter pulses (0..255)CT
93Page 2-{{0:Icon 8}}Send 1byte percent value, long1 Byte5.1 percentage (0..100%)CT
93Page 2-{{0:Icon 8}}Send 2byte unsigned value, long2 Bytes7.1 pulsesCT
93Page 2-{{0:Icon 8}}Send 2byte signed value, long2 Bytes8.1 pulses differenceCT
93Page 2-{{0:Icon 8}}Send 4byte unsigned value, long4 Bytes12.1 counter pulses (unsigned)CT
93Page 2-{{0:Icon 8}}Send 4byte float value, long4 BytesDPT.14CT
93Page 2-{{0:Icon 8}}Stop1 Bit1.7 stepCT
93Page 2-{{0:Icon 8}}Stop / Slat adj.1 Bit1.7 stepCT
94Page 2-{{0:Icon 8}}Status switching1 Bit1.1 switchCWTU
94Page 2-{{0:Icon 8}}Curtain position1 Byte5.1 percentage (0..100%)CT
94Page 2-{{0:Icon 8}}Blind position1 Byte5.1 percentage (0..100%)CT
94Page 2-{{0:Icon 8}}Display 1bit value1 Bit1.1 switchCWTU
94Page 2-{{0:Icon 8}}Display 1byte unsigned value1 Byte5.10 counter pulses (0..255)CWTU
94Page 2-{{0:Icon 8}}Display 1byte percentage value1 Byte5.1 percentage (0..100%)CWTU
94Page 2-{{0:Icon 8}}Display 2byte unsigned value2 Bytes7.1 pulsesCWTU
94Page 2-{{0:Icon 8}}Display 2byte signed value2 Bytes8.1 pulses differenceCWTU
94Page 2-{{0:Icon 8}}Display 2byte float value2 BytesDPT.9CWTU
94Page 2-{{0:Icon 8}}Display temperature value2 Bytes9.1 temperature (°C)CWTU
94Page 2-{{0:Icon 8}}Display pressure value2 Bytes9.6 pressure (Pa)CWTU
94Page 2-{{0:Icon 8}}Display humidity value2 Bytes9.7 humidity (%)CWTU
94Page 2-{{0:Icon 8}}Display CO2 value2 Bytes9.8 parts/million (ppm)CWTU
94Page 2-{{0:Icon 8}}Display air flow value2 Bytes9.9 air flow (m³/h)CWTU
94Page 2-{{0:Icon 8}}Display concentration value2 Bytes9.30 concentration (µg/m³)CWTU
94Page 2-{{0:Icon 8}}Display 4byte unsigned value4 Bytes12.1 counter pulses (unsigned)CWTU
94Page 2-{{0:Icon 8}}Display 4byte float value4 BytesDPT.14CWTU
94Page 2-{{0:Icon 8}}Display text14 Bytes16.1 Character String (ISO 8859-1)CW
95Page 2-{{0:Icon 8}}Dimming4 Bit3.7 dimming controlCWT
95Page 2-{{0:Icon 8}}Color temperature value2 Bytes7.600 absolute colour temperature (K)CT
95Page 2-{{0:Icon 8}}Warm white brightness1 Byte5.1 percentage (0..100%)CT
95Page 2-{{0:Icon 8}}Slat position1 Byte5.1 percentage (0..100%)CT
96Page 2-{{0:Icon 8}}Status dim value1 Byte5.1 percentage (0..100%)CWTU
96Page 2-{{0:Icon 8}}Cool white brightness, status1 Byte5.1 percentage (0..100%)CWTU
96Page 2-{{0:Icon 8}}Status curtain position1 Byte5.1 percentage (0..100%)CWTU
96Page 2-{{0:Icon 8}}Status blind position1 Byte5.1 percentage (0..100%)CWTU
97Page 2-{{0:Icon 8}}Status color temperature value2 Bytes7.600 absolute colour temperature (K)CWTU
97Page 2-{{0:Icon 8}}Warm white brightness, status1 Byte5.1 percentage (0..100%)CWTU
97Page 2-{{0:Icon 8}}Status slat position1 Byte5.1 percentage (0..100%)CWTU
98Page 2-{{0}}Lock1 Bit1.3 enableCW
99Page 3-{{0:Icon 1}}Switching1 Bit1.1 switchCT
99Page 3-{{0:Icon 1}}Send 1bit value1 Bit1.1 switchCT
99Page 3-{{0:Icon 1}}Send 2bit value2 Bit2.1 switch controlCT
99Page 3-{{0:Icon 1}}Send 4bit value4 Bit3.7 dimming controlCT
99Page 3-{{0:Icon 1}}Send 1byte unsigned value1 Byte5.10 counter pulses (0..255)CT
99Page 3-{{0:Icon 1}}Send 1byte percent value1 Byte5.1 percentage (0..100%)CT
99Page 3-{{0:Icon 1}}Send 2byte unsigned value2 Bytes7.1 pulsesCT
99Page 3-{{0:Icon 1}}Send 2byte signed value2 Bytes8.1 pulses differenceCT
99Page 3-{{0:Icon 1}}Send 4byte unsigned value4 Bytes12.1 counter pulses (unsigned)CT
99Page 3-{{0:Icon 1}}Send 4byte float value4 BytesDPT.14CT
99Page 3-{{0:Icon 1}}Open / Close1 Bit1.9 open/closeCWT
99Page 3-{{0:Icon 1}}Up / Down1 Bit1.8 up/downCWT
99Page 3-{{0:Icon 1}}Recall / Save scene1 Byte18.1 scene controlCT
99Page 3-{{0:Icon 1}}Recall / Save scene1 Byte18.1 scene controlCWT
99Page 3-{{0:Icon 1}}Bell function1 Bit1.1 switchCT
100Page 3-{{0:Icon 1}}Dim value1 Byte5.1 percentage (0..100%)CT
100Page 3-{{0:Icon 1}}Cool white brightness1 Byte5.1 percentage (0..100%)CT
100Page 3-{{0:Icon 1}}Send 1bit value, long1 Bit1.1 switchCT
100Page 3-{{0:Icon 1}}Send 2bit value, long2 Bit2.1 switch controlCT
100Page 3-{{0:Icon 1}}Send 4bit value, long4 Bit3.7 dimming controlCT
100Page 3-{{0:Icon 1}}Send 1byte unsigned value, long1 Byte5.10 counter pulses (0..255)CT
100Page 3-{{0:Icon 1}}Send 1byte percent value, long1 Byte5.1 percentage (0..100%)CT
100Page 3-{{0:Icon 1}}Send 2byte unsigned value, long2 Bytes7.1 pulsesCT
100Page 3-{{0:Icon 1}}Send 2byte signed value, long2 Bytes8.1 pulses differenceCT
100Page 3-{{0:Icon 1}}Send 4byte unsigned value, long4 Bytes12.1 counter pulses (unsigned)CT
100Page 3-{{0:Icon 1}}Send 4byte float value, long4 BytesDPT.14CT
100Page 3-{{0:Icon 1}}Stop1 Bit1.7 stepCT
100Page 3-{{0:Icon 1}}Stop / Slat adj.1 Bit1.7 stepCT
101Page 3-{{0:Icon 1}}Status switching1 Bit1.1 switchCWTU
101Page 3-{{0:Icon 1}}Curtain position1 Byte5.1 percentage (0..100%)CT
101Page 3-{{0:Icon 1}}Blind position1 Byte5.1 percentage (0..100%)CT
101Page 3-{{0:Icon 1}}Display 1bit value1 Bit1.1 switchCWTU
101Page 3-{{0:Icon 1}}Display 1byte unsigned value1 Byte5.10 counter pulses (0..255)CWTU
101Page 3-{{0:Icon 1}}Display 1byte percentage value1 Byte5.1 percentage (0..100%)CWTU
101Page 3-{{0:Icon 1}}Display 2byte unsigned value2 Bytes7.1 pulsesCWTU
101Page 3-{{0:Icon 1}}Display 2byte signed value2 Bytes8.1 pulses differenceCWTU
101Page 3-{{0:Icon 1}}Display 2byte float value2 BytesDPT.9CWTU
101Page 3-{{0:Icon 1}}Display temperature value2 Bytes9.1 temperature (°C)CWTU
101Page 3-{{0:Icon 1}}Display pressure value2 Bytes9.6 pressure (Pa)CWTU
101Page 3-{{0:Icon 1}}Display humidity value2 Bytes9.7 humidity (%)CWTU
101Page 3-{{0:Icon 1}}Display CO2 value2 Bytes9.8 parts/million (ppm)CWTU
101Page 3-{{0:Icon 1}}Display air flow value2 Bytes9.9 air flow (m³/h)CWTU
101Page 3-{{0:Icon 1}}Display concentration value2 Bytes9.30 concentration (µg/m³)CWTU
101Page 3-{{0:Icon 1}}Display 4byte unsigned value4 Bytes12.1 counter pulses (unsigned)CWTU
101Page 3-{{0:Icon 1}}Display 4byte float value4 BytesDPT.14CWTU
101Page 3-{{0:Icon 1}}Display text14 Bytes16.1 Character String (ISO 8859-1)CW
102Page 3-{{0:Icon 1}}Dimming4 Bit3.7 dimming controlCWT
102Page 3-{{0:Icon 1}}Color temperature value2 Bytes7.600 absolute colour temperature (K)CT
102Page 3-{{0:Icon 1}}Warm white brightness1 Byte5.1 percentage (0..100%)CT
102Page 3-{{0:Icon 1}}Slat position1 Byte5.1 percentage (0..100%)CT
103Page 3-{{0:Icon 1}}Status dim value1 Byte5.1 percentage (0..100%)CWTU
103Page 3-{{0:Icon 1}}Cool white brightness, status1 Byte5.1 percentage (0..100%)CWTU
103Page 3-{{0:Icon 1}}Status curtain position1 Byte5.1 percentage (0..100%)CWTU
103Page 3-{{0:Icon 1}}Status blind position1 Byte5.1 percentage (0..100%)CWTU
104Page 3-{{0:Icon 1}}Status color temperature value2 Bytes7.600 absolute colour temperature (K)CWTU
104Page 3-{{0:Icon 1}}Warm white brightness, status1 Byte5.1 percentage (0..100%)CWTU
104Page 3-{{0:Icon 1}}Status slat position1 Byte5.1 percentage (0..100%)CWTU
105Page 3-{{0:Icon 2}}Switching1 Bit1.1 switchCT
105Page 3-{{0:Icon 2}}Send 1bit value1 Bit1.1 switchCT
105Page 3-{{0:Icon 2}}Send 2bit value2 Bit2.1 switch controlCT
105Page 3-{{0:Icon 2}}Send 4bit value4 Bit3.7 dimming controlCT
105Page 3-{{0:Icon 2}}Send 1byte unsigned value1 Byte5.10 counter pulses (0..255)CT
105Page 3-{{0:Icon 2}}Send 1byte percent value1 Byte5.1 percentage (0..100%)CT
105Page 3-{{0:Icon 2}}Send 2byte unsigned value2 Bytes7.1 pulsesCT
105Page 3-{{0:Icon 2}}Send 2byte signed value2 Bytes8.1 pulses differenceCT
105Page 3-{{0:Icon 2}}Send 4byte unsigned value4 Bytes12.1 counter pulses (unsigned)CT
105Page 3-{{0:Icon 2}}Send 4byte float value4 BytesDPT.14CT
105Page 3-{{0:Icon 2}}Open / Close1 Bit1.9 open/closeCWT
105Page 3-{{0:Icon 2}}Up / Down1 Bit1.8 up/downCWT
105Page 3-{{0:Icon 2}}Recall / Save scene1 Byte18.1 scene controlCT
105Page 3-{{0:Icon 2}}Recall / Save scene1 Byte18.1 scene controlCWT
105Page 3-{{0:Icon 2}}Bell function1 Bit1.1 switchCT
106Page 3-{{0:Icon 2}}Dim value1 Byte5.1 percentage (0..100%)CT
106Page 3-{{0:Icon 2}}Cool white brightness1 Byte5.1 percentage (0..100%)CT
106Page 3-{{0:Icon 2}}Send 1bit value, long1 Bit1.1 switchCT
106Page 3-{{0:Icon 2}}Send 2bit value, long2 Bit2.1 switch controlCT
106Page 3-{{0:Icon 2}}Send 4bit value, long4 Bit3.7 dimming controlCT
106Page 3-{{0:Icon 2}}Send 1byte unsigned value, long1 Byte5.10 counter pulses (0..255)CT
106Page 3-{{0:Icon 2}}Send 1byte percent value, long1 Byte5.1 percentage (0..100%)CT
106Page 3-{{0:Icon 2}}Send 2byte unsigned value, long2 Bytes7.1 pulsesCT
106Page 3-{{0:Icon 2}}Send 2byte signed value, long2 Bytes8.1 pulses differenceCT
106Page 3-{{0:Icon 2}}Send 4byte unsigned value4 Bytes12.1 counter pulses (unsigned)CT
106Page 3-{{0:Icon 2}}Send 4byte float value, long4 BytesDPT.14CT
106Page 3-{{0:Icon 2}}Stop1 Bit1.7 stepCT
106Page 3-{{0:Icon 2}}Stop / Slat adj.1 Bit1.7 stepCT
107Page 3-{{0:Icon 2}}Status switching1 Bit1.1 switchCWTU

First 1000 of 11128 group objects shown. Download the .knxprod for the full list.

Parameters (693)
ParameterTypeDefault
Display operator languagelistEnglish
Language nametextInput name
Cycle time for sending status "In operation" [0...240, 0=disabled]time0
Date and time changeable via busunsignedInt 0…11
Screen brightness changeable via busunsignedInt 0…11
Page style for multifunction pagelistBig Icons
Indicate the control status throughlistIcon only
Display temperature inlistdegree Celsius
Screen saverlistClock
Turn off backlight after [0...255] (0 = backlight never off)unsignedInt 0…25530
Password functionunsignedInt 0…10
Send status objects after restartunsignedInt 0…11
Auto return to homepage from function page if no operation in [0...255, 0=disabled]time60
Description/ Headline of the pagetext
Home page 1unsignedInt 0…11
Page layout - icons per pagelist4
Icon 1 - navigation functionunsignedInt 0…11
Link tolistPage 1
Select page iconlistMultifunction
Function page 1unsignedInt 0…11
Number of iconslist4
Icon 1unsignedInt 0…11
Select iconlistLight
Description of icon 1text
Function of icon 1listSwitch
Data typelist1bit [On/Off]
Send value when short presslistOff
Send value when short pressunsignedInt 0…30
Send value when short pressunsignedInt 0…150
Send value when short pressunsignedInt 0…255100
Send value when short presslist0
Send value when short pressunsignedInt 0…655350
Send value when short presssignedInt -32768…327670
Long press operationunsignedInt 0…10
Send value when long presslistOn
Send value when long pressunsignedInt 0…31
Send value when long pressunsignedInt 0…151
Send value when long pressunsignedInt 0…2550
Send value when long presslist1
Send value when long pressunsignedInt 0…6553532768
Send value when long presssignedInt -32768…327671
Scene number for short presslistScene No.1
Long press for scene storageunsignedInt 0…10
Send daytime/nighttime statuslistNo
Time for switch to night at: Hour [0..23]time18
Time for switch to night at: Minute [0..59]time0
Time for switch to day at: Hour [0..23]time6
Time for switch to day at: Minute [0..59]time0
LatitudelistNorth
Latitude in degrees [0...90]unsignedInt 0…9052
Latitude in minutes [0...59]unsignedInt 0…5931
LongitudelistEast
Longitude in degrees [0...180]unsignedInt 0…18013
Longitude in minutes [0...59]unsignedInt 0…5924
Icon 2unsignedInt 0…11
Description of icon 2text
Function of icon 2listSwitch
Icon 3unsignedInt 0…11
Description of icon 3text
Function of icon 3listSwitch
Icon 4unsignedInt 0…11
Description of icon 4text
Function of icon 4listSwitch
Icon 5unsignedInt 0…11
Description of icon 5text
Function of icon 5listSwitch
Icon 6unsignedInt 0…11
Description of icon 6text
Function of icon 6listSwitch
Icon 7unsignedInt 0…11
Description of icon 7text
Function of icon 7listSwitch
Icon 8unsignedInt 0…11
Description of icon 8text
Function of icon 8listSwitch
Page functionlistMultifunction (Lighting/Blind/Scene/Send value/Display)
Timer 1unsignedInt 0…11
Timer 2unsignedInt 0…10
Timer 3unsignedInt 0…10
Timer 4unsignedInt 0…10
Timer 5unsignedInt 0…10
Timer 6unsignedInt 0…10
Timer 7unsignedInt 0…10
Timer 8unsignedInt 0…10
Timer 9unsignedInt 0…10
Timer 10unsignedInt 0…10
Timer 11unsignedInt 0…10
Timer 12unsignedInt 0…10
Timer 13unsignedInt 0…10
Timer 14unsignedInt 0…10
Timer 15unsignedInt 0…10
Timer 16unsignedInt 0…10
Data size of timerlist1byte
Predefined value: On / OfflistOff
Predefined value [0...255]unsignedInt 0…255127
Predefined Scene No. [1...64]listScene No.1
Predefined value [0...65535]unsignedInt 0…6553532767
Description of timertext
Timer disablelistDisable
Monday isunsignedInt 0…10
Tuesday isunsignedInt 0…10
Wednesday isunsignedInt 0…10
Thursday isunsignedInt 0…10
Friday isunsignedInt 0…10
Saturday isunsignedInt 0…10
Sunday isunsignedInt 0…10
Scene Group 1unsignedInt 0…11
Scene Group 2unsignedInt 0…10
Scene Group 3unsignedInt 0…10
Scene Group 4unsignedInt 0…10
Scene Group 5unsignedInt 0…10
Scene Group 6unsignedInt 0…10
Scene Group 7unsignedInt 0…10
Scene Group 8unsignedInt 0…10
Data sizelist1bit
1: Trigger scene No. [0...64, 0=inactive]unsignedInt 0…640
Predefined value: [0...1]list0
Send after [0...255]unsignedInt 0…2550
2: Trigger scene No. [0...64, 0=inactive]unsignedInt 0…640
3: Trigger scene No. [0...64, 0=inactive]unsignedInt 0…640
4: Trigger scene No. [0...64, 0=inactive]unsignedInt 0…640
5: Trigger scene No. [0...64, 0=inactive]unsignedInt 0…640
6: Trigger scene No. [0...64, 0=inactive]unsignedInt 0…640
7: Trigger scene No. [0...64, 0=inactive]unsignedInt 0…640
8: Trigger scene No. [0...64, 0=inactive]unsignedInt 0…640
Logic - No.1unsignedInt 0…10
Logic operationlistAND
Input alistDisconnected
Default valuelist0
Input blistDisconnected
Input clistDisconnected
Input dlistDisconnected
Input elistDisconnected
Input flistDisconnected
Input glistDisconnected
Input hlistDisconnected
Invert logical outputunsignedInt 0…10
Read input value after bus recoveryunsignedInt 0…10
Data type of Threshold valuelist1byte unsigned (DPT5.010)
Threshold value [0...15]unsignedInt 0…158
Threshold value [0...255]unsignedInt 0…255127
Threshold value [0...65535]unsignedInt 0…6553532768
Threshold value [0...4294967295]unsignedInt 0…429496729565536
If Object value<Threshold valuelistDo not send telegram
If Object value=Threshold valuelistDo not send telegram
If Object value!=Threshold valuelistDo not send telegram
If Object value>Threshold valuelistDo not send telegram
If Object value<=Threshold valuelistDo not send telegram
If Object value>=Threshold valuelistDo not send telegram
Send result whenlistNew input received
Time delay of sending: base [s]listNone
Time delay of sending: factor [1...255]unsignedInt 1…2551
Format conversionlist1x1Byte-->8x1Bit
Data type of Input/Output objectlist1bit
Scene No. to be forwarded at startup [0...64, 0=inactive]unsignedInt 0…640
1: Gate trigger Scene No. [1...64, 0=inactive]unsignedInt 0…640
Define Output for Input AlistOutput A
Define Output for Input BlistOutput B
Define Output for Input ClistOutput C
Define Output for Input DlistOutput D
2: Gate trigger Scene No. [1...64, 0=inactive]unsignedInt 0…640
3: Gate trigger Scene No. [1...64, 0=inactive]unsignedInt 0…640
4: Gate trigger Scene No. [1...64, 0=inactive]unsignedInt 0…640
5: Gate trigger Scene No. [1...64, 0=inactive]unsignedInt 0…640
6: Gate trigger Scene No. [1...64, 0=inactive]unsignedInt 0…640
7: Gate trigger Scene No. [1...64, 0=inactive]unsignedInt 0…640
8: Gate trigger Scene No. [1...64, 0=inactive]unsignedInt 0…640
Switch to nighttime after sunset in [-128...127]signedInt -128…1270
Latitude longitude location settingtextBerlin, Germany
Color strip functionunsignedInt 0…10
Brightness level at daytime [Level1 - darkest; Level5 - brightest]listLevel 1
Switch to daytime after sunrise in [-128...127]signedInt -128…1270
Offset to measured valuelist0
Change of actual temperature value for automatic sending [0...10]list1.0K
Cycle time for automatic sending of the actual temperature value [0...255]time10
Send error status of internal sensorlistSend status on change
Error status object meaninglist0=no error/1=error
Show item 1listInt. temperature
Cycle time for polling of external temperature value [0..255]time10
Send read request for external temperatureunsignedInt 0…11
Color 1 settinglistWhite
TimerunsignedInt 0…10
Scene controlunsignedInt 0…10
Color strip working modelistOnly active when backlight is off
Brightness level at nighttimelistOFF
Icon number associatedlist1
Icon 2 - navigation functionunsignedInt 0…11
Link tolistPage 2
Icon 3 - navigation functionunsignedInt 0…11
Link tolistPage 3
Icon 4 - navigation functionunsignedInt 0…11
Link tolistPage 4
Icon 5 - navigation functionunsignedInt 0…11
Link tolistPage 5
Icon 6 - navigation functionunsignedInt 0…11
Link tolistPage 6
Icon 7 - navigation functionunsignedInt 0…11
Link tolistPage 7
Icon 8 - navigation functionunsignedInt 0…11
Link tolistPage 8
Home page 2unsignedInt 0…10
Color strip working mode, when activelistSlowly flashing
Proximity sensor response functionunsignedInt 0…11
Output value [On/Off]listOn
Output scene No. [1...64]listScene No.1
Output value [0...255]unsignedInt 0…255255
Output value [0...100]unsignedInt 0…100100
Send value after [0...255]time0
Action when people approachinglistSend a value
Data type of output valuelist1bit [On/Off]
Output value [On/Off]listOff
Output scene No. [1...64]listScene No.2
Output value [0...255]unsignedInt 0…2550
Output value [0..100]unsignedInt 0…1000
Send value after [5...255]time10
Action when people leavinglistNo action
Time difference from Universal Time [UTC + ...]list(UTC +01:00) Amsterdam, Berlin, Bern, Rome, Vienna
Action after being unlockedlistNo action
Output value [0...100]unsignedInt 0…1000
Password 2 - Wake-up the screenunsignedInt 0…10
Password 3 - Wake-up the screenunsignedInt 0…10
Output scene No. [1...64]listScene No.3
Summer time adjustmentlistNo
Start at monthlistMarch
Start at weeklistThe last week
Start at daylistSunday
Start at hour [0...23]unsignedInt 0…232
Start at minute [0...59]unsignedInt 0…590
End at monthlistOctober
End at weeklistThe last week
End at daylistSunday
End at hour [0...23]unsignedInt 0…233
End at minute [0...59]unsignedInt 0…590
Description for password 1textPassword 1
Description for password 2textPassword 2
Description for password 3textPassword 3
Display modelistVertical
Date display formatlistMM-DD
Screen stylelistDark screen
Delay for sending status objects after voltage recovery [0...15]time5
Password 1 applies tolistWake-up the screen
Logic functionunsignedInt 0…10
Home page 3unsignedInt 0…10
Home page 4unsignedInt 0…10
Home page 5unsignedInt 0…10
Automatic switch between internal and external temperature on displayunsignedInt 0…10
Show item 2listHumidity
Min. color temperature [2000...7000]unsignedInt 2000…70002700
Max. color temperature [2000...7000]unsignedInt 2000…70006500
Password 1unsignedInt 0…91
Password 1unsignedInt 0…92
Password 1unsignedInt 0…93
Password 1unsignedInt 0…94
Password 2unsignedInt 0…92
Password 2unsignedInt 0…93
Password 2unsignedInt 0…94
Password 2unsignedInt 0…95
Password 3unsignedInt 0…93
Password 3unsignedInt 0…94
Password 3unsignedInt 0…95
Password 3unsignedInt 0…96
Color temperature Control typelistNormal
Function page 6unsignedInt 0…10
Status feedback objectlistBrightness+Color Temperature
Activate screen saver after [5...255]time10
Function page 2unsignedInt 0…10
Function page 3unsignedInt 0…10
Function page 4unsignedInt 0…10
Function page 5unsignedInt 0…10
Function page 7unsignedInt 0…10
Function page 8unsignedInt 0…10
Function page 9unsignedInt 0…10
Function page 10unsignedInt 0…10
Function page 11unsignedInt 0…10
Function page 12unsignedInt 0…10
Function page 13unsignedInt 0…10
Function page 14unsignedInt 0…10
Function page 15unsignedInt 0…10
Operation modelistSingle
Temperature value fromlistInternal sensor
Cycle time for polling of external temperature value [0...255]time5
Read external sensor after restartunsignedInt 0…11
Weighting of internal and external valuelist50% internal, 50% external
Change of actual temperature value for automatic sendinglist1.0K
Cycle time for automatic sending of the actual temperature value [0...255, 0=disabled]time0
Control value after temp. error [0...100] (For 2-level control, the value '0'=0%, value '>0'=100%)unsignedInt 0…1000
Device behavior after downloadlistOn
Device behavior after voltage recoverylistAs before voltage failure
Minimal possible setpoint value [5...40]list5
Maximal possible setpoint value [5...40]list40
Data type of fan speedlistDisable
1 bit object for fan speed offunsignedInt 0…10
Auto Operation (demand based ventilation)unsignedInt 0…11
Data type of Fan speedlistPercentage (DPT_5.001)
Fan speed - Switching pointunsignedInt 1…10010
Fan speed - LowunsignedInt 1…10033
Fan speed - MediumunsignedInt 1…10067
Fan speed - HighunsignedInt 1…100100
Fan speed - Switching pointunsignedInt 1…2551
Fan speed - LowunsignedInt 1…2551
Fan speed - MediumunsignedInt 1…2552
Fan speed - HighunsignedInt 1…2553
Room temperature control modelistHeating
Room operation modeunsignedInt 0…11
Base setpointlist20.0
Object type of operating modelist1Byte
Room operation mode after downloadlistComfort mode
Room operation mode after voltage recoverylistAs before voltage failure
Duration for extended comfort mode [0...255, 0=disabled]time0
Setpoint configuration bylistBase setpoint + setpoint shifting
Standby mode: Setpoint shifting heating [0...10]list2
Economy mode: Setpoint shifting heating [0...10]list4
Protection mode: Setpoint heating [5...10]list7
Comfort mode: Setpoint heating [5...40]list22
Standby mode: Setpoint heating [5...40]list20
Economy mode: Setpoint heating [5...40]list18
Command TypelistOn/Off - two level control
Invert control valueunsignedInt 0…10
Lower Hysteresis [0...200]unsignedInt 0…20020
Upper Hysteresis [0...200]unsignedInt 0…20020
Pulse width modulation period time [1...255]time15
Heating LooplistHot water heating (5K/150min)
Proportional range [10...100]unsignedInt 10…10050
Integration time [0...255]time240
Send value on change of control value by [0...100, 0=disabled]unsignedInt 0…1004
Send control value cyclically [0...255]time0
Standby mode: Setpoint shifting cooling [0...10]list2
Economy mode: Setpoint shifting cooling [0...10]list4
Protection mode: Setpoint cooling [30...40]list35
Comfort mode: Setpoint cooling [5...40]list22
Standby mode: Setpoint cooling [5...40]list24
Economy mode: Setpoint cooling [5...40]list26
Cooling LooplistChilled ceiling (5K/240min)
Proportional range [10...100]unsignedInt 10…10040
Integration time [0...255]time150
Heating/Cooling switchoverlistVia both screen and object
Control mode after downloadlistHeating
Control mode after voltage recoverylistAs before voltage failure
Room temperature control systemlist4 pipes system
Upper dead zonelist2.0
Lower dead zonelist2.0
Minimum zone between heating and cooling setpointlist2.0
Window contact inputunsignedInt 0…10
Delay for window contact[0...65535]time15
Room operation mode for open windowlistProtection mode
Presence detector inputunsignedInt 0…10
Timer functionunsignedInt 0…10
ON/OFF protectionunsignedInt 0…10
Control mode protectionunsignedInt 0…10
Fan protectionunsignedInt 0…10
Setpoint protectionunsignedInt 0…10
Operation mode protectionunsignedInt 0…10
Control typelistVRV/VRF gateway
Command No. for Power off[1..64,0=inactive]unsignedInt 0…641
Command No. for Power on[1..64,0=inactive]unsignedInt 0…642
Default mode for power onlistFan
Default setpoint for power onlist25
Default fan speed for power onlistAuto
Default setpoint for Heatlist22
Default setpoint for Coollist25
Command No. for Dry mode[1..64,0=inactive]unsignedInt 0…643
Command No. for Fan mode[1..64,0=inactive]unsignedInt 0…644
Command No. for Auto mode[1..64,0=inactive]unsignedInt 0…645
Command No. for Fan speed-auto[1..64,0=inactive]unsignedInt 0…646
Command No. for Fan speed-low[1..64,0=inactive]unsignedInt 0…647
Command No. for Fan speed-medium[1..64,0=inactive]unsignedInt 0…648
Command No. for Fan speed-high[1..64,0=inactive]unsignedInt 0…649
Command No. for setpoint 16°C [1..64,0=inactive]unsignedInt 0…6416
Command No. for setpoint 17°C [1..64,0=inactive]unsignedInt 0…6417
Command No. for setpoint 18°C [1..64,0=inactive]unsignedInt 0…6418
Command No. for setpoint 19°C [1..64,0=inactive]unsignedInt 0…6419
Command No. for setpoint 20°C [1..64,0=inactive]unsignedInt 0…6420
Command No. for setpoint 21°C [1..64,0=inactive]unsignedInt 0…6421
Command No. for setpoint 22°C [1..64,0=inactive]unsignedInt 0…6422
Command No. for setpoint 23°C [1..64,0=inactive]unsignedInt 0…6423
Command No. for setpoint 24°C [1..64,0=inactive]unsignedInt 0…6424
Command No. for setpoint 25°C [1..64,0=inactive]unsignedInt 0…6425
Command No. for setpoint 26°C [1..64,0=inactive]unsignedInt 0…6426
Command No. for setpoint 27°C [1..64,0=inactive]unsignedInt 0…6427
Command No. for setpoint 28°C [1..64,0=inactive]unsignedInt 0…6428
Command No. for setpoint 29°C [1..64,0=inactive]unsignedInt 0…6429
Command No. for setpoint 30°C [1..64,0=inactive]unsignedInt 0…6430
Command No. for setpoint 31°C [1..64,0=inactive]unsignedInt 0…6431
Command No. for setpoint 32°C [1..64,0=inactive]unsignedInt 0…6432
Command No. for setpoint 16°C [1..64,0=inactive]unsignedInt 0…6433
Command No. for setpoint 17°C [1..64,0=inactive]unsignedInt 0…6434
Command No. for setpoint 18°C [1..64,0=inactive]unsignedInt 0…6435
Command No. for setpoint 19°C [1..64,0=inactive]unsignedInt 0…6436
Command No. for setpoint 20°C [1..64,0=inactive]unsignedInt 0…6437
Command No. for setpoint 21°C [1..64,0=inactive]unsignedInt 0…6438
Command No. for setpoint 22°C [1..64,0=inactive]unsignedInt 0…6439
Command No. for setpoint 23°C [1..64,0=inactive]unsignedInt 0…6440
Command No. for setpoint 24°C [1..64,0=inactive]unsignedInt 0…6441
Command No. for setpoint 25°C [1..64,0=inactive]unsignedInt 0…6442
Command No. for setpoint 26°C [1..64,0=inactive]unsignedInt 0…6443
Command No. for setpoint 27°C [1..64,0=inactive]unsignedInt 0…6444
Command No. for setpoint 28°C [1..64,0=inactive]unsignedInt 0…6445
Command No. for setpoint 29°C [1..64,0=inactive]unsignedInt 0…6446
Command No. for setpoint 30°C [1..64,0=inactive]unsignedInt 0…6447
Command No. for setpoint 31°C [1..64,0=inactive]unsignedInt 0…6448
Command No. for setpoint 32°C [1..64,0=inactive]unsignedInt 0…6449
Data type of setpointlistFloat value in °C (DPT_9.001)
Minimal possible setpoint value [16...32]list16
Maximal possible setpoint value [16...32]list32
Data type of fan speedlist1byte
Vanes swingunsignedInt 0…10
Vanes positionunsignedInt 0…10
Mode protectionunsignedInt 0…10
Vanes swing protectionunsignedInt 0…10
Data type of modelist1byte
Predefined value for Autolist1
Predefined value for Heatinglist1
Predefined value for Coolinglist0
Predefined value for Fanlist1
Predefined value for Dehumidificationlist1
Auto modeunsignedInt 0…11
Predefined value for AutounsignedInt 0…2550
Status value for AutounsignedInt 0…2550
Heating modeunsignedInt 0…11
Predefined value for HeatingunsignedInt 0…2551
Status value for HeatingunsignedInt 0…2551
Cooling modeunsignedInt 0…11
Predefined value for CoolingunsignedInt 0…2553
Status value for CoolingunsignedInt 0…2553
Fan modeunsignedInt 0…11
Predefined value for FanunsignedInt 0…2559
Status value for FanunsignedInt 0…2559
Dehumidification modeunsignedInt 0…11
Predefined value for DehumidificationunsignedInt 0…25514
Status value for DehumidificationunsignedInt 0…25514
Data type of fan speedlistPercentage (DPT_5.001)
Predefined value for fan speed autounsignedInt 0…1000
Predefined value for fan speed lowunsignedInt 0…10033
Predefined value for fan speed mediumunsignedInt 0…10067
Predefined value for fan speed highunsignedInt 0…100100
Predefined value for fan speed autounsignedInt 0…2550
Predefined value for position 1unsignedInt 0…2551
Predefined value for position 2unsignedInt 0…2552
Predefined value for position 3unsignedInt 0…2553
Predefined value for position 4unsignedInt 0…2554
Predefined value for position 5unsignedInt 0…2555
Power on/offunsignedInt 0…11
Control mode of volume adjustmentlist1Bit (relative control)
MuteunsignedInt 0…10
Object datatypelistPercentage (DPT_5.001)
Max. volume value [10...100]unsignedInt 10…100100
Track nameunsignedInt 0…10
Artist nameunsignedInt 0…10
Album nameunsignedInt 0…10
Play modeunsignedInt 0…11
Predefined value for single cycleunsignedInt 0…2550
Predefined value for random playunsignedInt 0…2551
Predefined value for playlist cycleunsignedInt 0…2552
Predefined value for play in orderunsignedInt 0…2553
Output value for USBunsignedInt 0…2550
Output value for SDunsignedInt 0…2551
Output value for AUXunsignedInt 0…2552
Output value for FMunsignedInt 0…2553
Output value for BTunsignedInt 0…2554
Status value for USBunsignedInt 0…2550
Status value for SDunsignedInt 0…2551
Status value for AUXunsignedInt 0…2552
Status value for FMunsignedInt 0…2553
Status value for BTunsignedInt 0…2554
Lighting typelistRGB
RGB data typelist1x3byte
RGBW data typelist1x6byte
Function of item 1 in display listlistTemperature
Descriptiontext
Function of item 2 in display listlistHumidity
Function of item 3 in display listlistPM2.5
Function of item 4 in display listlistVOC
Cycle time for polling of external value [5...255]time5
Datatype of PM2.5listValue in ug/m3 (DPT_7.001)
Datatype of PM10listValue in ug/m3 (DPT_7.001)
Datatype of CO2listFloat value in ppm (DPT_9.008)
Datatype of VOClistValue in ug/m3 (DPT_7.001)
Datatype of BrightnesslistFloat value in lux (DPT_9.004)
Datatype of WindspeedlistFloat value in m/s (DPT_9.005)
Default temperature setpoint [16...32]list22
Object value of Heating on/offlistHeat on=1, Heat off=0
Send control value cyclically [0...255]time15
1: Assign scene No.[0...64, 0=inactive ]unsignedInt 0…640
Floor heating state for a scenelistOn
Temp. Setpoint [16...32]list20
2: Assign scene No.[0...64, 0=inactive ]unsignedInt 0…640
3: Assign scene No.[0...64, 0=inactive ]unsignedInt 0…640
4: Assign scene No.[0...64, 0=inactive ]unsignedInt 0…640
5: Assign scene No.[0...64, 0=inactive ]unsignedInt 0…640
Behavior ventilation after downloadlistOn
Behavior ventilation after voltage recoverylistOff
Default fan speed after ventilation onlistLow
Heat Recovery functionlistDisable=0/Enable=1
Filter lifetime countingunsignedInt 0…10
Filter life time [100...10000]time1000
Auto Operation (Demand based ventilation)unsignedInt 0…10
Object value: Fan speed - OfflistNo.1=0, No.2=0, No.3=0
Object value: Fan speed - LowlistNo.1=1, No.2=0, No.3=0
Object value: Fan speed - MediumlistNo.1=0, No.2=1, No.3=0
Object value: Fan speed - HighlistNo.1=0, No.2=0, No.3=1

First 500 of 693 parameters shown. Download the .knxprod for the full list.

Version history

ApplicationApp noFingerprintFirst seenSizeFile
07B0 Touch Control SE 989603 0.3 latest$9896D4672026-11-252.5 MBDownload

About this file

This is the official ETS product database for the Siemens UP 205/x2 Touch Control TC5 (5WG1205-2AB_2), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.