KNX Database
Siemens 5WG1 536-1DB51 Switch-/Dimm actuator N 536D51, 8x AC 230 V, 1…10V

Switch-/Dimm actuator N 536D51, 8x AC 230 V, 1…10V 5WG1 536-1DB51

Siemens · Order number 5WG1 536-1DB51 · Lighting › Switching/Dimming Actuator › N-Devices › N 536D51

Switch-/Dimm actuator N 536D51, 8x AC 230 V, 1…10V

Download .knxprod 07 B0 A8 Switch-/Dimm actuator 8-fold 9A0602 0.2 · 1.5 MB

Product

ManufacturerSiemens
Product nameSwitch-/Dimm actuator N 536D51, 8x AC 230 V, 1…10V
Order number5WG1 536-1DB51
HardwareHardwareEntry.0.9A06
MediumTwisted Pair
Bus current (mA)25
Rail mountedYes
RegistrationRegistered · 2018-06-22
Languagesen-US, de-DE, it-IT, fr-FR, es-ES, sv-SE
Catalog entryM-0001_H-hp.5F00318-1_HP-9A06-02-6F6C_CI-5WG1.20536.2D1DB51-1
Fingerprint6F6C
SHA-256e62e5de6400f7daca936efca92c45942b898c13c2e0e58cdd61aff2d1c8ac830
First seen2026-11-25
Markets59 markets

Application program: 07 B0 A8 Switch-/Dimm actuator 8-fold 9A0602 0.2

Application number$9A06
Version0.2
Mask versionMV-07B0 (System B)
KNX Data SecureNo
Minimum ETS version4.0
Parameters4470
Group objects3090
Group objects (3090)
NoNameFunctionSizeDPTFlags
1Status device functionok / defect1 Bit1.5 alarmCRT
2Send status valuesrequest1 Bit1.17 triggerCW
3A SwitchingOn / Off1 Bit1.1 switchCW
4A Control ValueValue1 Byte5.10 counter pulses (0..255)CW
4A Control ValueValue2 Bytes9.1 temperature (°C)CW
4A Control ValueValue1 Byte5.1 percentage (0..100%)CW
4A Control ValueValue2 Bytes9.4 lux (Lux)CW
4A Control ValueValue2 Bytes9.21 current (mA)CW
4A Control ValueValue2 Bytes9.24 power (kW)CW
4A Control ValueValue4 Bytes14.56 power (W)CW
5A DimmingBrighter / darker4 Bit3.7 dimming controlCW
6A Dimming value 18-bit value1 Byte5.1 percentage (0..100%)CW
7A Dimming value 28-bit value1 Byte5.1 percentage (0..100%)CW
8A Dimming value 1 / timeDimming value + time3 BytesCW
9A Dimming value 1 / timeDimming value + time3 BytesCW
10A Status switchingOn / Off1 Bit1.1 switchCRT
11A Status dimming value8-bit value1 Byte5.1 percentage (0..100%)CRT
12A Minimum dimming valueSet / Request Value1 Byte5.1 percentage (0..100%)CRW
13A Maximum dimming valueSet / Request Value1 Byte5.1 percentage (0..100%)CRW
14A Dimming time for switchingSet / Request dimming time2 Bytes7.4 time (100 ms)CRW
15A Dimming time for dimmingSet / Request dimming time2 Bytes7.4 time (100 ms)CRW
16A Dimming time for dimming value 1Set / Request dimming time2 Bytes7.4 time (100 ms)CRW
17A Dimming time for dimming value 2Set / Request dimming time2 Bytes7.4 time (100 ms)CRW
18A Logic operation 1On / Off1 Bit1.1 switchCW
19A Logic operation 2On / Off1 Bit1.1 switchCW
20A Central SwitchingOn / Off1 Bit1.1 switchCW
21A 8-bit scenerecall / store 1 Byte18.1 scene controlCW
22A Scene value/timeValue / Time3 BytesCW
23A Night modeOn / Off1 Bit1.3 enableCW
24A Night mode timerON time (seconds)2 Bytes7.5 time (s)CRW
25A Day mode timerON time 1 (seconds)2 Bytes7.5 time (s)CRW
26A Forced controlOn / Off2 Bit2.1 switch controlCW
27A Pre-warning expiration of timer periodOn / Off1 Bit1.1 switchCRT
28A Lock TimerOn / Off1 Bit1.3 enableCW
29A Override 1, Permanent OFFOn / Off1 Bit1.3 enableCW
29A Override 1, Manual ONOn / Off1 Bit1.3 enableCW
29A Override 1, LockOn / Off1 Bit1.3 enableCW
29A Override 1, Central ControlOn / Off1 Bit1.3 enableCW
29A Override 1, User-defined ControlOn / Off1 Bit1.3 enableCW
30A Override 1, Permanent OFF, Control ValueValue1 Byte5.10 counter pulses (0..255)CW
30A Override 1, Manual ON, Control ValueValue1 Byte5.10 counter pulses (0..255)CW
30A Override 1, Lock, ControlValue1 Byte5.10 counter pulses (0..255)CW
30A Override 1, Central Control, ControlValue1 Byte5.10 counter pulses (0..255)CW
30A Override 1, User-defined Control, Control ValueValue1 Byte5.10 counter pulses (0..255)CW
30A Override 1, Permanent OFF, Control ValueValue2 Bytes9.1 temperature (°C)CW
30A Override 1, Manual ON, Control ValueValue2 Bytes9.1 temperature (°C)CW
30A Override 1, Lock, ControlValue2 Bytes9.1 temperature (°C)CW
30A Override 1, Central Control, ControlValue2 Bytes9.1 temperature (°C)CW
30A Override 1, User-defined Control, Control ValueValue2 Bytes9.1 temperature (°C)CW
30A Override 1, Permanent OFF, Control ValueValue1 Byte5.1 percentage (0..100%)CW
30A Override 1, Manual ON, Control ValueValue1 Byte5.1 percentage (0..100%)CW
30A Override 1, Lock, ControlValue1 Byte5.1 percentage (0..100%)CW
30A Override 1, Central Control, ControlValue1 Byte5.1 percentage (0..100%)CW
30A Override 1, User-defined Control, Control ValueValue1 Byte5.1 percentage (0..100%)CW
30A Override 1, Permanent OFF, Control ValueValue2 Bytes9.4 lux (Lux)CW
30A Override 1, Manual ON, Control ValueValue2 Bytes9.4 lux (Lux)CW
30A Override 1, Lock, ControlValue2 Bytes9.4 lux (Lux)CW
30A Override 1, Central Control, ControlValue2 Bytes9.4 lux (Lux)CW
30A Override 1, User-defined Control, Control ValueValue2 Bytes9.4 lux (Lux)CW
30A Override 1, Permanent OFF, Control ValueValue2 Bytes9.21 current (mA)CW
30A Override 1, Manual ON, Control ValueValue2 Bytes9.21 current (mA)CW
30A Override 1, Lock, ControlValue2 Bytes9.21 current (mA)CW
30A Override 1, Central Control, ControlValue2 Bytes9.21 current (mA)CW
30A Override 1, User-defined Control, Control ValueValue2 Bytes9.21 current (mA)CW
30A Override 1, Permanent OFF, Control ValueValue2 Bytes9.24 power (kW)CW
30A Override 1, Manual ON, Control ValueValue2 Bytes9.24 power (kW)CW
30A Override 1, Lock, ControlValue2 Bytes9.24 power (kW)CW
30A Override 1, Central Control, ControlValue2 Bytes9.24 power (kW)CW
30A Override 1, User-defined Control, Control ValueValue2 Bytes9.24 power (kW)CW
30A Override 1, Permanent OFF, Control ValueValue4 Bytes14.56 power (W)CW
30A Override 1, Manual ON, Control ValueValue4 Bytes14.56 power (W)CW
30A Override 1, Lock, ControlValue4 Bytes14.56 power (W)CW
30A Override 1, Central Control, ControlValue4 Bytes14.56 power (W)CW
30A Override 1, User-defined Control, Control ValueValue4 Bytes14.56 power (W)CW
31A Override 1, Forced ControlOn / Off2 Bit2.1 switch controlCW
32A Override 1, Permanent-OFF, StatusOn / Off1 Bit1.2 booleanCRT
32A Override 1, Manual ON, StatusOn / Off1 Bit1.2 booleanCRT
32A Override 1, Lock, StatusOn / Off1 Bit1.2 booleanCRT
32A Override 1, Central Control, StatusOn / Off1 Bit1.2 booleanCRT
32A Override 1, User-defined Control, StatusOn / Off1 Bit1.2 booleanCRT
32A Override 1, Forced Control, StatusOn / Off1 Bit1.2 booleanCRT
33A Override 2, Permanent OFFOn / Off1 Bit1.3 enableCW
33A Override 2, Manual ONOn / Off1 Bit1.3 enableCW
33A Override 2, LockOn / Off1 Bit1.3 enableCW
33A Override 2, Central ControlOn / Off1 Bit1.3 enableCW
33A Override 2, User-defined ControlOn / Off1 Bit1.3 enableCW
34A Override 2, Permanent OFF, Control ValueValue1 Byte5.10 counter pulses (0..255)CW
34A Override 2, Manual ON, Control ValueValue1 Byte5.10 counter pulses (0..255)CW
34A Override 2, Lock, ControlValue1 Byte5.10 counter pulses (0..255)CW
34A Override 2, Central Control, ControlValue1 Byte5.10 counter pulses (0..255)CW
34A Override 2, User-defined Control, Control ValueValue1 Byte5.10 counter pulses (0..255)CW
34A Override 2, Permanent OFF, Control ValueValue2 Bytes9.1 temperature (°C)CW
34A Override 2, Manual ON, Control ValueValue2 Bytes9.1 temperature (°C)CW
34A Override 2, Lock, ControlValue2 Bytes9.1 temperature (°C)CW
34A Override 2, Central Control, ControlValue2 Bytes9.1 temperature (°C)CW
34A Override 2, User-defined Control, Control ValueValue2 Bytes9.1 temperature (°C)CW
34A Override 2, Permanent OFF, Control ValueValue1 Byte5.1 percentage (0..100%)CW
34A Override 2, Manual ON, Control ValueValue1 Byte5.1 percentage (0..100%)CW
34A Override 2, Lock, ControlValue1 Byte5.1 percentage (0..100%)CW
34A Override 2, Central Control, ControlValue1 Byte5.1 percentage (0..100%)CW
34A Override 2, User-defined Control, Control ValueValue1 Byte5.1 percentage (0..100%)CW
34A Override 2, Permanent OFF, Control ValueValue2 Bytes9.4 lux (Lux)CW
34A Override 2, Manual ON, Control ValueValue2 Bytes9.4 lux (Lux)CW
34A Override 2, Lock, ControlValue2 Bytes9.4 lux (Lux)CW
34A Override 2, Central Control, ControlValue2 Bytes9.4 lux (Lux)CW
34A Override 2, User-defined Control, Control ValueValue2 Bytes9.4 lux (Lux)CW
34A Override 2, Permanent OFF, Control ValueValue2 Bytes9.21 current (mA)CW
34A Override 2, Manual ON, Control ValueValue2 Bytes9.21 current (mA)CW
34A Override 2, Lock, ControlValue2 Bytes9.21 current (mA)CW
34A Override 2, Central Control, ControlValue2 Bytes9.21 current (mA)CW
34A Override 2, User-defined Control, Control ValueValue2 Bytes9.21 current (mA)CW
34A Override 2, Permanent OFF, Control ValueValue2 Bytes9.24 power (kW)CW
34A Override 2, Manual ON, Control ValueValue2 Bytes9.24 power (kW)CW
34A Override 2, Lock, ControlValue2 Bytes9.24 power (kW)CW
34A Override 2, Central Control, ControlValue2 Bytes9.24 power (kW)CW
34A Override 2, User-defined Control, Control ValueValue2 Bytes9.24 power (kW)CW
34A Override 2, Permanent OFF, Control ValueValue4 Bytes14.56 power (W)CW
34A Override 2, Manual ON, Control ValueValue4 Bytes14.56 power (W)CW
34A Override 2, Lock, ControlValue4 Bytes14.56 power (W)CW
34A Override 2, Central Control, ControlValue4 Bytes14.56 power (W)CW
34A Override 2, User-defined Control, Control ValueValue4 Bytes14.56 power (W)CW
35A Override 2, Forced ControlOn / Off2 Bit2.1 switch controlCW
36A Override 2, Permanent-OFF, StatusOn / Off1 Bit1.2 booleanCRT
36A Override 2, Manual ON, StatusOn / Off1 Bit1.2 booleanCRT
36A Override 2, Lock, StatusOn / Off1 Bit1.2 booleanCRT
36A Override 2, Central Control, StatusOn / Off1 Bit1.2 booleanCRT
36A Override 2, User-defined Control, StatusOn / Off1 Bit1.2 booleanCRT
36A Override 2, Forced Control, StatusOn / Off1 Bit1.2 booleanCRT
37A Override 3, Permanent OFFOn / Off1 Bit1.3 enableCW
37A Override 3, Manual ONOn / Off1 Bit1.3 enableCW
37A Override 3, LockOn / Off1 Bit1.3 enableCW
37A Override 3, Central ControlOn / Off1 Bit1.3 enableCW
37A Override 3, User-defined ControlOn / Off1 Bit1.3 enableCW
38A Override 3, Permanent OFF, Control ValueValue1 Byte5.10 counter pulses (0..255)CW
38A Override 3, Manual ON, Control ValueValue1 Byte5.10 counter pulses (0..255)CW
38A Override 3, Lock, ControlValue1 Byte5.10 counter pulses (0..255)CW
38A Override 3, Central Control, ControlValue1 Byte5.10 counter pulses (0..255)CW
38A Override 3, User-defined Control, Control ValueValue1 Byte5.10 counter pulses (0..255)CW
38A Override 3, Permanent OFF, Control ValueValue2 Bytes9.1 temperature (°C)CW
38A Override 3, Manual ON, Control ValueValue2 Bytes9.1 temperature (°C)CW
38A Override 3, Lock, ControlValue2 Bytes9.1 temperature (°C)CW
38A Override 3, Central Control, ControlValue2 Bytes9.1 temperature (°C)CW
38A Override 3, User-defined Control, Control ValueValue2 Bytes9.1 temperature (°C)CW
38A Override 3, Permanent OFF, Control ValueValue1 Byte5.1 percentage (0..100%)CW
38A Override 3, Manual ON, Control ValueValue1 Byte5.1 percentage (0..100%)CW
38A Override 3, Lock, ControlValue1 Byte5.1 percentage (0..100%)CW
38A Override 3, Central Control, ControlValue1 Byte5.1 percentage (0..100%)CW
38A Override 3, User-defined Control, Control ValueValue1 Byte5.1 percentage (0..100%)CW
38A Override 3, Permanent OFF, Control ValueValue2 Bytes9.4 lux (Lux)CW
38A Override 3, Manual ON, Control ValueValue2 Bytes9.4 lux (Lux)CW
38A Override 3, Lock, ControlValue2 Bytes9.4 lux (Lux)CW
38A Override 3, Central Control, ControlValue2 Bytes9.4 lux (Lux)CW
38A Override 3, User-defined Control, Control ValueValue2 Bytes9.4 lux (Lux)CW
38A Override 3, Permanent OFF, Control ValueValue2 Bytes9.21 current (mA)CW
38A Override 3, Manual ON, Control ValueValue2 Bytes9.21 current (mA)CW
38A Override 3, Lock, ControlValue2 Bytes9.21 current (mA)CW
38A Override 3, Central Control, ControlValue2 Bytes9.21 current (mA)CW
38A Override 3, User-defined Control, Control ValueValue2 Bytes9.21 current (mA)CW
38A Override 3, Permanent OFF, Control ValueValue2 Bytes9.24 power (kW)CW
38A Override 3, Manual ON, Control ValueValue2 Bytes9.24 power (kW)CW
38A Override 3, Lock, ControlValue2 Bytes9.24 power (kW)CW
38A Override 3, Central Control, ControlValue2 Bytes9.24 power (kW)CW
38A Override 3, User-defined Control, Control ValueValue2 Bytes9.24 power (kW)CW
38A Override 3, Permanent OFF, Control ValueValue4 Bytes14.56 power (W)CW
38A Override 3, Manual ON, Control ValueValue4 Bytes14.56 power (W)CW
38A Override 3, Lock, ControlValue4 Bytes14.56 power (W)CW
38A Override 3, Central Control, ControlValue4 Bytes14.56 power (W)CW
38A Override 3, User-defined Control, Control ValueValue4 Bytes14.56 power (W)CW
39A Override 3, Forced ControlOn / Off2 Bit2.1 switch controlCW
40A Override 3, Permanent-OFF, StatusOn / Off1 Bit1.2 booleanCRT
40A Override 3, Manual ON, StatusOn / Off1 Bit1.2 booleanCRT
40A Override 3, Lock, StatusOn / Off1 Bit1.2 booleanCRT
40A Override 3, Central Control, StatusOn / Off1 Bit1.2 booleanCRT
40A Override 3, User-defined Control, StatusOn / Off1 Bit1.2 booleanCRT
40A Override 3, Forced Control, StatusOn / Off1 Bit1.2 booleanCRT
41A Override 4, Permanent OFFOn / Off1 Bit1.3 enableCW
41A Override 4, Manual ONOn / Off1 Bit1.3 enableCW
41A Override 4, LockOn / Off1 Bit1.3 enableCW
41A Override 4, Central ControlOn / Off1 Bit1.3 enableCW
41A Override 4, User-defined ControlOn / Off1 Bit1.3 enableCW
42A Override 4, Permanent OFF, Control ValueValue1 Byte5.10 counter pulses (0..255)CW
42A Override 4, Manual ON, Control ValueValue1 Byte5.10 counter pulses (0..255)CW
42A Override 4, Lock, ControlValue1 Byte5.10 counter pulses (0..255)CW
42A Override 4, Central Control, ControlValue1 Byte5.10 counter pulses (0..255)CW
42A Override 4, User-defined Control, Control ValueValue1 Byte5.10 counter pulses (0..255)CW
42A Override 4, Permanent OFF, Control ValueValue2 Bytes9.1 temperature (°C)CW
42A Override 4, Manual ON, Control ValueValue2 Bytes9.1 temperature (°C)CW
42A Override 4, Lock, ControlValue2 Bytes9.1 temperature (°C)CW
42A Override 4, Central Control, ControlValue2 Bytes9.1 temperature (°C)CW
42A Override 4, User-defined Control, Control ValueValue2 Bytes9.1 temperature (°C)CW
42A Override 4, Permanent OFF, Control ValueValue1 Byte5.1 percentage (0..100%)CW
42A Override 4, Manual ON, Control ValueValue1 Byte5.1 percentage (0..100%)CW
42A Override 4, Lock, ControlValue1 Byte5.1 percentage (0..100%)CW
42A Override 4, Central Control, ControlValue1 Byte5.1 percentage (0..100%)CW
42A Override 4, User-defined Control, Control ValueValue1 Byte5.1 percentage (0..100%)CW
42A Override 4, Permanent OFF, Control ValueValue2 Bytes9.4 lux (Lux)CW
42A Override 4, Manual ON, Control ValueValue2 Bytes9.4 lux (Lux)CW
42A Override 4, Lock, ControlValue2 Bytes9.4 lux (Lux)CW
42A Override 4, Central Control, ControlValue2 Bytes9.4 lux (Lux)CW
42A Override 4, User-defined Control, Control ValueValue2 Bytes9.4 lux (Lux)CW
42A Override 4, Permanent OFF, Control ValueValue2 Bytes9.21 current (mA)CW
42A Override 4, Manual ON, Control ValueValue2 Bytes9.21 current (mA)CW
42A Override 4, Lock, ControlValue2 Bytes9.21 current (mA)CW
42A Override 4, Central Control, ControlValue2 Bytes9.21 current (mA)CW
42A Override 4, User-defined Control, Control ValueValue2 Bytes9.21 current (mA)CW
42A Override 4, Permanent OFF, Control ValueValue2 Bytes9.24 power (kW)CW
42A Override 4, Manual ON, Control ValueValue2 Bytes9.24 power (kW)CW
42A Override 4, Lock, ControlValue2 Bytes9.24 power (kW)CW
42A Override 4, Central Control, ControlValue2 Bytes9.24 power (kW)CW
42A Override 4, User-defined Control, Control ValueValue2 Bytes9.24 power (kW)CW
42A Override 4, Permanent OFF, Control ValueValue4 Bytes14.56 power (W)CW
42A Override 4, Manual ON, Control ValueValue4 Bytes14.56 power (W)CW
42A Override 4, Lock, ControlValue4 Bytes14.56 power (W)CW
42A Override 4, Central Control, ControlValue4 Bytes14.56 power (W)CW
42A Override 4, User-defined Control, Control ValueValue4 Bytes14.56 power (W)CW
43A Override 4, Forced ControlOn / Off2 Bit2.1 switch controlCW
44A Override 4, Permanent-OFF, StatusOn / Off1 Bit1.2 booleanCRT
44A Override 4, Manual ON, StatusOn / Off1 Bit1.2 booleanCRT
44A Override 4, Lock, StatusOn / Off1 Bit1.2 booleanCRT
44A Override 4, Central Control, StatusOn / Off1 Bit1.2 booleanCRT
44A Override 4, User-defined Control, StatusOn / Off1 Bit1.2 booleanCRT
44A Override 4, Forced Control, StatusOn / Off1 Bit1.2 booleanCRT
45A Override 5, Permanent OFFOn / Off1 Bit1.3 enableCW
45A Override 5, Manual ONOn / Off1 Bit1.3 enableCW
45A Override 5, LockOn / Off1 Bit1.3 enableCW
45A Override 5, Central ControlOn / Off1 Bit1.3 enableCW
45A Override 5, User-defined ControlOn / Off1 Bit1.3 enableCW
46A Override 5, Permanent OFF, Control ValueValue1 Byte5.10 counter pulses (0..255)CW
46A Override 5, Manual ON, Control ValueValue1 Byte5.10 counter pulses (0..255)CW
46A Override 5, Lock, ControlValue1 Byte5.10 counter pulses (0..255)CW
46A Override 5, Central Control, ControlValue1 Byte5.10 counter pulses (0..255)CW
46A Override 5, User-defined Control, Control ValueValue1 Byte5.10 counter pulses (0..255)CW
46A Override 5, Permanent OFF, Control ValueValue2 Bytes9.1 temperature (°C)CW
46A Override 5, Manual ON, Control ValueValue2 Bytes9.1 temperature (°C)CW
46A Override 5, Lock, ControlValue2 Bytes9.1 temperature (°C)CW
46A Override 5, Central Control, ControlValue2 Bytes9.1 temperature (°C)CW
46A Override 5, User-defined Control, Control ValueValue2 Bytes9.1 temperature (°C)CW
46A Override 5, Permanent OFF, Control ValueValue1 Byte5.1 percentage (0..100%)CW
46A Override 5, Manual ON, Control ValueValue1 Byte5.1 percentage (0..100%)CW
46A Override 5, Lock, ControlValue1 Byte5.1 percentage (0..100%)CW
46A Override 5, Central Control, ControlValue1 Byte5.1 percentage (0..100%)CW
46A Override 5, User-defined Control, Control ValueValue1 Byte5.1 percentage (0..100%)CW
46A Override 5, Permanent OFF, Control ValueValue2 Bytes9.4 lux (Lux)CW
46A Override 5, Manual ON, Control ValueValue2 Bytes9.4 lux (Lux)CW
46A Override 5, Lock, ControlValue2 Bytes9.4 lux (Lux)CW
46A Override 5, Central Control, ControlValue2 Bytes9.4 lux (Lux)CW
46A Override 5, User-defined Control, Control ValueValue2 Bytes9.4 lux (Lux)CW
46A Override 5, Permanent OFF, Control ValueValue2 Bytes9.21 current (mA)CW
46A Override 5, Manual ON, Control ValueValue2 Bytes9.21 current (mA)CW
46A Override 5, Lock, ControlValue2 Bytes9.21 current (mA)CW
46A Override 5, Central Control, ControlValue2 Bytes9.21 current (mA)CW
46A Override 5, User-defined Control, Control ValueValue2 Bytes9.21 current (mA)CW
46A Override 5, Permanent OFF, Control ValueValue2 Bytes9.24 power (kW)CW
46A Override 5, Manual ON, Control ValueValue2 Bytes9.24 power (kW)CW
46A Override 5, Lock, ControlValue2 Bytes9.24 power (kW)CW
46A Override 5, Central Control, ControlValue2 Bytes9.24 power (kW)CW
46A Override 5, User-defined Control, Control ValueValue2 Bytes9.24 power (kW)CW
46A Override 5, Permanent OFF, Control ValueValue4 Bytes14.56 power (W)CW
46A Override 5, Manual ON, Control ValueValue4 Bytes14.56 power (W)CW
46A Override 5, Lock, ControlValue4 Bytes14.56 power (W)CW
46A Override 5, Central Control, ControlValue4 Bytes14.56 power (W)CW
46A Override 5, User-defined Control, Control ValueValue4 Bytes14.56 power (W)CW
47A Override 5, Forced ControlOn / Off2 Bit2.1 switch controlCW
48A Override 5, Permanent-OFF, StatusOn / Off1 Bit1.2 booleanCRT
48A Override 5, Manual ON, StatusOn / Off1 Bit1.2 booleanCRT
48A Override 5, Lock, StatusOn / Off1 Bit1.2 booleanCRT
48A Override 5, Central Control, StatusOn / Off1 Bit1.2 booleanCRT
48A Override 5, User-defined Control, StatusOn / Off1 Bit1.2 booleanCRT
48A Override 5, Forced Control, StatusOn / Off1 Bit1.2 booleanCRT
49A Override 6, Permanent OFFOn / Off1 Bit1.3 enableCW
49A Override 6, Manual ONOn / Off1 Bit1.3 enableCW
49A Override 6, LockOn / Off1 Bit1.3 enableCW
49A Override 6, Central ControlOn / Off1 Bit1.3 enableCW
49A Override 6, User-defined ControlOn / Off1 Bit1.3 enableCW
50A Override 6, Permanent OFF, Control ValueValue1 Byte5.10 counter pulses (0..255)CW
50A Override 6, Manual ON, Control ValueValue1 Byte5.10 counter pulses (0..255)CW
50A Override 6, Lock, ControlValue1 Byte5.10 counter pulses (0..255)CW
50A Override 6, Central Control, ControlValue1 Byte5.10 counter pulses (0..255)CW
50A Override 6, User-defined Control, Control ValueValue1 Byte5.10 counter pulses (0..255)CW
50A Override 6, Permanent OFF, Control ValueValue2 Bytes9.1 temperature (°C)CW
50A Override 6, Manual ON, Control ValueValue2 Bytes9.1 temperature (°C)CW
50A Override 6, Lock, ControlValue2 Bytes9.1 temperature (°C)CW
50A Override 6, Central Control, ControlValue2 Bytes9.1 temperature (°C)CW
50A Override 6, User-defined Control, Control ValueValue2 Bytes9.1 temperature (°C)CW
50A Override 6, Permanent OFF, Control ValueValue1 Byte5.1 percentage (0..100%)CW
50A Override 6, Manual ON, Control ValueValue1 Byte5.1 percentage (0..100%)CW
50A Override 6, Lock, ControlValue1 Byte5.1 percentage (0..100%)CW
50A Override 6, Central Control, ControlValue1 Byte5.1 percentage (0..100%)CW
50A Override 6, User-defined Control, Control ValueValue1 Byte5.1 percentage (0..100%)CW
50A Override 6, Permanent OFF, Control ValueValue2 Bytes9.4 lux (Lux)CW
50A Override 6, Manual ON, Control ValueValue2 Bytes9.4 lux (Lux)CW
50A Override 6, Lock, ControlValue2 Bytes9.4 lux (Lux)CW
50A Override 6, Central Control, ControlValue2 Bytes9.4 lux (Lux)CW
50A Override 6, User-defined Control, Control ValueValue2 Bytes9.4 lux (Lux)CW
50A Override 6, Permanent OFF, Control ValueValue2 Bytes9.21 current (mA)CW
50A Override 6, Manual ON, Control ValueValue2 Bytes9.21 current (mA)CW
50A Override 6, Lock, ControlValue2 Bytes9.21 current (mA)CW
50A Override 6, Central Control, ControlValue2 Bytes9.21 current (mA)CW
50A Override 6, User-defined Control, Control ValueValue2 Bytes9.21 current (mA)CW
50A Override 6, Permanent OFF, Control ValueValue2 Bytes9.24 power (kW)CW
50A Override 6, Manual ON, Control ValueValue2 Bytes9.24 power (kW)CW
50A Override 6, Lock, ControlValue2 Bytes9.24 power (kW)CW
50A Override 6, Central Control, ControlValue2 Bytes9.24 power (kW)CW
50A Override 6, User-defined Control, Control ValueValue2 Bytes9.24 power (kW)CW
50A Override 6, Permanent OFF, Control ValueValue4 Bytes14.56 power (W)CW
50A Override 6, Manual ON, Control ValueValue4 Bytes14.56 power (W)CW
50A Override 6, Lock, ControlValue4 Bytes14.56 power (W)CW
50A Override 6, Central Control, ControlValue4 Bytes14.56 power (W)CW
50A Override 6, User-defined Control, Control ValueValue4 Bytes14.56 power (W)CW
51A Override 6, Forced ControlOn / Off2 Bit2.1 switch controlCW
52A Override 6, Permanent-OFF, StatusOn / Off1 Bit1.2 booleanCRT
52A Override 6, Manual ON, StatusOn / Off1 Bit1.2 booleanCRT
52A Override 6, Lock, StatusOn / Off1 Bit1.2 booleanCRT
52A Override 6, Central Control, StatusOn / Off1 Bit1.2 booleanCRT
52A Override 6, User-defined Control, StatusOn / Off1 Bit1.2 booleanCRT
52A Override 6, Forced Control, StatusOn / Off1 Bit1.2 booleanCRT
53A Override 7, Permanent OFFOn / Off1 Bit1.3 enableCW
53A Override 7, Manual ONOn / Off1 Bit1.3 enableCW
53A Override 7, LockOn / Off1 Bit1.3 enableCW
53A Override 7, Central ControlOn / Off1 Bit1.3 enableCW
53A Override 7, User-defined ControlOn / Off1 Bit1.3 enableCW
54A Override 7, Permanent OFF, Control ValueValue1 Byte5.10 counter pulses (0..255)CW
54A Override 7, Manual ON, Control ValueValue1 Byte5.10 counter pulses (0..255)CW
54A Override 7, Lock, ControlValue1 Byte5.10 counter pulses (0..255)CW
54A Override 7, Central Control, ControlValue1 Byte5.10 counter pulses (0..255)CW
54A Override 7, User-defined Control, Control ValueValue1 Byte5.10 counter pulses (0..255)CW
54A Override 7, Permanent OFF, Control ValueValue2 Bytes9.1 temperature (°C)CW
54A Override 7, Manual ON, Control ValueValue2 Bytes9.1 temperature (°C)CW
54A Override 7, Lock, ControlValue2 Bytes9.1 temperature (°C)CW
54A Override 7, Central Control, ControlValue2 Bytes9.1 temperature (°C)CW
54A Override 7, User-defined Control, Control ValueValue2 Bytes9.1 temperature (°C)CW
54A Override 7, Permanent OFF, Control ValueValue1 Byte5.1 percentage (0..100%)CW
54A Override 7, Manual ON, Control ValueValue1 Byte5.1 percentage (0..100%)CW
54A Override 7, Lock, ControlValue1 Byte5.1 percentage (0..100%)CW
54A Override 7, Central Control, ControlValue1 Byte5.1 percentage (0..100%)CW
54A Override 7, User-defined Control, Control ValueValue1 Byte5.1 percentage (0..100%)CW
54A Override 7, Permanent OFF, Control ValueValue2 Bytes9.4 lux (Lux)CW
54A Override 7, Manual ON, Control ValueValue2 Bytes9.4 lux (Lux)CW
54A Override 7, Lock, ControlValue2 Bytes9.4 lux (Lux)CW
54A Override 7, Central Control, ControlValue2 Bytes9.4 lux (Lux)CW
54A Override 7, User-defined Control, Control ValueValue2 Bytes9.4 lux (Lux)CW
54A Override 7, Permanent OFF, Control ValueValue2 Bytes9.21 current (mA)CW
54A Override 7, Manual ON, Control ValueValue2 Bytes9.21 current (mA)CW
54A Override 7, Lock, ControlValue2 Bytes9.21 current (mA)CW
54A Override 7, Central Control, ControlValue2 Bytes9.21 current (mA)CW
54A Override 7, User-defined Control, Control ValueValue2 Bytes9.21 current (mA)CW
54A Override 7, Permanent OFF, Control ValueValue2 Bytes9.24 power (kW)CW
54A Override 7, Manual ON, Control ValueValue2 Bytes9.24 power (kW)CW
54A Override 7, Lock, ControlValue2 Bytes9.24 power (kW)CW
54A Override 7, Central Control, ControlValue2 Bytes9.24 power (kW)CW
54A Override 7, User-defined Control, Control ValueValue2 Bytes9.24 power (kW)CW
54A Override 7, Permanent OFF, Control ValueValue4 Bytes14.56 power (W)CW
54A Override 7, Manual ON, Control ValueValue4 Bytes14.56 power (W)CW
54A Override 7, Lock, ControlValue4 Bytes14.56 power (W)CW
54A Override 7, Central Control, ControlValue4 Bytes14.56 power (W)CW
54A Override 7, User-defined Control, Control ValueValue4 Bytes14.56 power (W)CW
55A Override 7, Forced ControlOn / Off2 Bit2.1 switch controlCW
56A Override 7, Permanent-OFF, StatusOn / Off1 Bit1.2 booleanCRT
56A Override 7, Manual ON, StatusOn / Off1 Bit1.2 booleanCRT
56A Override 7, Lock, StatusOn / Off1 Bit1.2 booleanCRT
56A Override 7, Central Control, StatusOn / Off1 Bit1.2 booleanCRT
56A Override 7, User-defined Control, StatusOn / Off1 Bit1.2 booleanCRT
56A Override 7, Forced Control, StatusOn / Off1 Bit1.2 booleanCRT
57A Overrides status1 = Active1 Bit1.2 booleanCRT
58A Global dimming max. limit8 bit value1 Byte5.1 percentage (0..100%)CW
59A Direct operation lockOn / Off1 Bit1.3 enableCW
60A Status direct operationOn / Off1 Bit1.2 booleanCRT
61dummydummy2 BytesCRT
62dummydummy1 Byte21.601 lighting actuator error informationCRT
63A Number of switching cyclesValue (in cycles)4 Bytes12.1 counter pulses (unsigned)CRT
64A Number for switching cyclesSet Value (in cycles)4 Bytes12.1 counter pulses (unsigned)CW
65A Threshold for switching cyclesSet / Request Value (in cycles)4 Bytes12.1 counter pulses (unsigned)CRW
66A Exceedance of threshold for switching cyclesOn / Off1 Bit1.2 booleanCRT
67A Operating hoursValue (in hours)4 Bytes12.1 counter pulses (unsigned)CRT
68A Operating hoursValue (in seconds)4 Bytes13.100 time lag (s)CRT
69A Operating hoursSet Value4 Bytes12.1 counter pulses (unsigned)CW
70A Threshold for operating hoursSet / Request Value4 Bytes12.1 counter pulses (unsigned)CRW
71A Exceedance of threshold for operating hoursOn / Off1 Bit1.2 booleanCRT
72A Load Check-measured valueCurrent (mA)2 Bytes7.12 current (mA)CRT
73A Load Check-measured valueCurrent (A)4 Bytes14.19 electric current (A)CRT
74A Load Check-Normal value storeOn1 Bit1.3 enableCW
75A Load Check-Normal value recallCurrent (mA)2 Bytes7.12 current (mA)CRT
76A Load Check-Normal value recallCurrent (A)4 Bytes14.19 electric current (A)CRT
77A Load Check-Exceedance of load check limit valueOn / Off1 Bit1.2 booleanCRT
78A Load Check-Shortfall of load check limit valueOn / Off1 Bit1.2 booleanCRT
79A Load Check-Contact FailureOn / Off1 Bit1.2 booleanCRT
80A Dimming value8-bit value1 Byte5.1 percentage (0..100%)CW
81A Dimming value / timeDimming value + time3 BytesCW
82B SwitchingOn / Off1 Bit1.1 switchCW
83B Control ValueValue1 Byte5.10 counter pulses (0..255)CW
83B Control ValueValue2 Bytes9.1 temperature (°C)CW
83B Control ValueValue1 Byte5.1 percentage (0..100%)CW
83B Control ValueValue2 Bytes9.4 lux (Lux)CW
83B Control ValueValue2 Bytes9.21 current (mA)CW
83B Control ValueValue2 Bytes9.24 power (kW)CW
83B Control ValueValue4 Bytes14.56 power (W)CW
84B DimmingBrighter / darker4 Bit3.7 dimming controlCW
85B Dimming value 18-bit value1 Byte5.1 percentage (0..100%)CW
86B Dimming value 28-bit value1 Byte5.1 percentage (0..100%)CW
87B Dimming value 1 / timeDimming value + time3 BytesCW
88B Dimming value 1 / timeDimming value + time3 BytesCW
89B Status switchingOn / Off1 Bit1.1 switchCRT
90B Status dimming value8-bit value1 Byte5.1 percentage (0..100%)CRT
91B Minimum dimming valueSet / Request Value1 Byte5.1 percentage (0..100%)CRW
92B Maximum dimming valueSet / Request Value1 Byte5.1 percentage (0..100%)CRW
93B Dimming time for switchingSet / Request dimming time2 Bytes7.4 time (100 ms)CRW
94B Dimming time for dimmingSet / Request dimming time2 Bytes7.4 time (100 ms)CRW
95B Dimming time for dimming value 1Set / Request dimming time2 Bytes7.4 time (100 ms)CRW
96B Dimming time for dimming value 2Set / Request dimming time2 Bytes7.4 time (100 ms)CRW
97B Logic operation 1On / Off1 Bit1.1 switchCW
98B Logic operation 2On / Off1 Bit1.1 switchCW
99B Central SwitchingOn / Off1 Bit1.1 switchCW
100B 8-bit scenerecall / store 1 Byte18.1 scene controlCW
101B Scene value/timeValue / Time3 BytesCW
102B Night modeOn / Off1 Bit1.3 enableCW
103B Night mode timerON time (seconds)2 Bytes7.5 time (s)CRW
104B Day mode timerON time 1 (seconds)2 Bytes7.5 time (s)CRW
105B Forced controlOn / Off2 Bit2.1 switch controlCW
106B Pre-warning expiration of timer periodOn / Off1 Bit1.1 switchCRT
107B Lock TimerOn / Off1 Bit1.3 enableCW
108B Override 1, Permanent OFFOn / Off1 Bit1.3 enableCW
108B Override 1, Manual ONOn / Off1 Bit1.3 enableCW
108B Override 1, LockOn / Off1 Bit1.3 enableCW
108B Override 1, Central ControlOn / Off1 Bit1.3 enableCW
108B Override 1, User-defined ControlOn / Off1 Bit1.3 enableCW
109B Override 1, Permanent OFF, Control ValueValue1 Byte5.10 counter pulses (0..255)CW
109B Override 1, Manual ON, Control ValueValue1 Byte5.10 counter pulses (0..255)CW
109B Override 1, Lock, ControlValue1 Byte5.10 counter pulses (0..255)CW
109B Override 1, Central Control, ControlValue1 Byte5.10 counter pulses (0..255)CW
109B Override 1, User-defined Control, Control ValueValue1 Byte5.10 counter pulses (0..255)CW
109B Override 1, Permanent OFF, Control ValueValue2 Bytes9.1 temperature (°C)CW
109B Override 1, Manual ON, Control ValueValue2 Bytes9.1 temperature (°C)CW
109B Override 1, Lock, ControlValue2 Bytes9.1 temperature (°C)CW
109B Override 1, Central Control, ControlValue2 Bytes9.1 temperature (°C)CW
109B Override 1, User-defined Control, Control ValueValue2 Bytes9.1 temperature (°C)CW
109B Override 1, Permanent OFF, Control ValueValue1 Byte5.1 percentage (0..100%)CW
109B Override 1, Manual ON, Control ValueValue1 Byte5.1 percentage (0..100%)CW
109B Override 1, Lock, ControlValue1 Byte5.1 percentage (0..100%)CW
109B Override 1, Central Control, ControlValue1 Byte5.1 percentage (0..100%)CW
109B Override 1, User-defined Control, Control ValueValue1 Byte5.1 percentage (0..100%)CW
109B Override 1, Permanent OFF, Control ValueValue2 Bytes9.4 lux (Lux)CW
109B Override 1, Manual ON, Control ValueValue2 Bytes9.4 lux (Lux)CW
109B Override 1, Lock, ControlValue2 Bytes9.4 lux (Lux)CW
109B Override 1, Central Control, ControlValue2 Bytes9.4 lux (Lux)CW
109B Override 1, User-defined Control, Control ValueValue2 Bytes9.4 lux (Lux)CW
109B Override 1, Permanent OFF, Control ValueValue2 Bytes9.21 current (mA)CW
109B Override 1, Manual ON, Control ValueValue2 Bytes9.21 current (mA)CW
109B Override 1, Lock, ControlValue2 Bytes9.21 current (mA)CW
109B Override 1, Central Control, ControlValue2 Bytes9.21 current (mA)CW
109B Override 1, User-defined Control, Control ValueValue2 Bytes9.21 current (mA)CW
109B Override 1, Permanent OFF, Control ValueValue2 Bytes9.24 power (kW)CW
109B Override 1, Manual ON, Control ValueValue2 Bytes9.24 power (kW)CW
109B Override 1, Lock, ControlValue2 Bytes9.24 power (kW)CW
109B Override 1, Central Control, ControlValue2 Bytes9.24 power (kW)CW
109B Override 1, User-defined Control, Control ValueValue2 Bytes9.24 power (kW)CW
109B Override 1, Permanent OFF, Control ValueValue4 Bytes14.56 power (W)CW
109B Override 1, Manual ON, Control ValueValue4 Bytes14.56 power (W)CW
109B Override 1, Lock, ControlValue4 Bytes14.56 power (W)CW
109B Override 1, Central Control, ControlValue4 Bytes14.56 power (W)CW
109B Override 1, User-defined Control, Control ValueValue4 Bytes14.56 power (W)CW
110B Override 1, Forced ControlOn / Off2 Bit2.1 switch controlCW
111B Override 1, Permanent-OFF, StatusOn / Off1 Bit1.2 booleanCRT
111B Override 1, Manual ON, StatusOn / Off1 Bit1.2 booleanCRT
111B Override 1, Lock, StatusOn / Off1 Bit1.2 booleanCRT
111B Override 1, Central Control, StatusOn / Off1 Bit1.2 booleanCRT
111B Override 1, User-defined Control, StatusOn / Off1 Bit1.2 booleanCRT
111B Override 1, Forced Control, StatusOn / Off1 Bit1.2 booleanCRT
112B Override 2, Permanent OFFOn / Off1 Bit1.3 enableCW
112B Override 2, Manual ONOn / Off1 Bit1.3 enableCW
112B Override 2, LockOn / Off1 Bit1.3 enableCW
112B Override 2, Central ControlOn / Off1 Bit1.3 enableCW
112B Override 2, User-defined ControlOn / Off1 Bit1.3 enableCW
113B Override 2, Permanent OFF, Control ValueValue1 Byte5.10 counter pulses (0..255)CW
113B Override 2, Manual ON, Control ValueValue1 Byte5.10 counter pulses (0..255)CW
113B Override 2, Lock, ControlValue1 Byte5.10 counter pulses (0..255)CW
113B Override 2, Central Control, ControlValue1 Byte5.10 counter pulses (0..255)CW
113B Override 2, User-defined Control, Control ValueValue1 Byte5.10 counter pulses (0..255)CW
113B Override 2, Permanent OFF, Control ValueValue2 Bytes9.1 temperature (°C)CW
113B Override 2, Manual ON, Control ValueValue2 Bytes9.1 temperature (°C)CW
113B Override 2, Lock, ControlValue2 Bytes9.1 temperature (°C)CW
113B Override 2, Central Control, ControlValue2 Bytes9.1 temperature (°C)CW
113B Override 2, User-defined Control, Control ValueValue2 Bytes9.1 temperature (°C)CW
113B Override 2, Permanent OFF, Control ValueValue1 Byte5.1 percentage (0..100%)CW
113B Override 2, Manual ON, Control ValueValue1 Byte5.1 percentage (0..100%)CW
113B Override 2, Lock, ControlValue1 Byte5.1 percentage (0..100%)CW
113B Override 2, Central Control, ControlValue1 Byte5.1 percentage (0..100%)CW
113B Override 2, User-defined Control, Control ValueValue1 Byte5.1 percentage (0..100%)CW
113B Override 2, Permanent OFF, Control ValueValue2 Bytes9.4 lux (Lux)CW
113B Override 2, Manual ON, Control ValueValue2 Bytes9.4 lux (Lux)CW
113B Override 2, Lock, ControlValue2 Bytes9.4 lux (Lux)CW
113B Override 2, Central Control, ControlValue2 Bytes9.4 lux (Lux)CW
113B Override 2, User-defined Control, Control ValueValue2 Bytes9.4 lux (Lux)CW
113B Override 2, Permanent OFF, Control ValueValue2 Bytes9.21 current (mA)CW
113B Override 2, Manual ON, Control ValueValue2 Bytes9.21 current (mA)CW
113B Override 2, Lock, ControlValue2 Bytes9.21 current (mA)CW
113B Override 2, Central Control, ControlValue2 Bytes9.21 current (mA)CW
113B Override 2, User-defined Control, Control ValueValue2 Bytes9.21 current (mA)CW
113B Override 2, Permanent OFF, Control ValueValue2 Bytes9.24 power (kW)CW
113B Override 2, Manual ON, Control ValueValue2 Bytes9.24 power (kW)CW
113B Override 2, Lock, ControlValue2 Bytes9.24 power (kW)CW
113B Override 2, Central Control, ControlValue2 Bytes9.24 power (kW)CW
113B Override 2, User-defined Control, Control ValueValue2 Bytes9.24 power (kW)CW
113B Override 2, Permanent OFF, Control ValueValue4 Bytes14.56 power (W)CW
113B Override 2, Manual ON, Control ValueValue4 Bytes14.56 power (W)CW
113B Override 2, Lock, ControlValue4 Bytes14.56 power (W)CW
113B Override 2, Central Control, ControlValue4 Bytes14.56 power (W)CW
113B Override 2, User-defined Control, Control ValueValue4 Bytes14.56 power (W)CW
114B Override 2, Forced ControlOn / Off2 Bit2.1 switch controlCW
115B Override 2, Permanent-OFF, StatusOn / Off1 Bit1.2 booleanCRT
115B Override 2, Manual ON, StatusOn / Off1 Bit1.2 booleanCRT
115B Override 2, Lock, StatusOn / Off1 Bit1.2 booleanCRT
115B Override 2, Central Control, StatusOn / Off1 Bit1.2 booleanCRT
115B Override 2, User-defined Control, StatusOn / Off1 Bit1.2 booleanCRT
115B Override 2, Forced Control, StatusOn / Off1 Bit1.2 booleanCRT
116B Override 3, Permanent OFFOn / Off1 Bit1.3 enableCW
116B Override 3, Manual ONOn / Off1 Bit1.3 enableCW
116B Override 3, LockOn / Off1 Bit1.3 enableCW
116B Override 3, Central ControlOn / Off1 Bit1.3 enableCW
116B Override 3, User-defined ControlOn / Off1 Bit1.3 enableCW
117B Override 3, Permanent OFF, Control ValueValue1 Byte5.10 counter pulses (0..255)CW
117B Override 3, Manual ON, Control ValueValue1 Byte5.10 counter pulses (0..255)CW
117B Override 3, Lock, ControlValue1 Byte5.10 counter pulses (0..255)CW
117B Override 3, Central Control, ControlValue1 Byte5.10 counter pulses (0..255)CW
117B Override 3, User-defined Control, Control ValueValue1 Byte5.10 counter pulses (0..255)CW
117B Override 3, Permanent OFF, Control ValueValue2 Bytes9.1 temperature (°C)CW
117B Override 3, Manual ON, Control ValueValue2 Bytes9.1 temperature (°C)CW
117B Override 3, Lock, ControlValue2 Bytes9.1 temperature (°C)CW
117B Override 3, Central Control, ControlValue2 Bytes9.1 temperature (°C)CW
117B Override 3, User-defined Control, Control ValueValue2 Bytes9.1 temperature (°C)CW
117B Override 3, Permanent OFF, Control ValueValue1 Byte5.1 percentage (0..100%)CW
117B Override 3, Manual ON, Control ValueValue1 Byte5.1 percentage (0..100%)CW
117B Override 3, Lock, ControlValue1 Byte5.1 percentage (0..100%)CW
117B Override 3, Central Control, ControlValue1 Byte5.1 percentage (0..100%)CW
117B Override 3, User-defined Control, Control ValueValue1 Byte5.1 percentage (0..100%)CW
117B Override 3, Permanent OFF, Control ValueValue2 Bytes9.4 lux (Lux)CW
117B Override 3, Manual ON, Control ValueValue2 Bytes9.4 lux (Lux)CW
117B Override 3, Lock, ControlValue2 Bytes9.4 lux (Lux)CW
117B Override 3, Central Control, ControlValue2 Bytes9.4 lux (Lux)CW
117B Override 3, User-defined Control, Control ValueValue2 Bytes9.4 lux (Lux)CW
117B Override 3, Permanent OFF, Control ValueValue2 Bytes9.21 current (mA)CW
117B Override 3, Manual ON, Control ValueValue2 Bytes9.21 current (mA)CW
117B Override 3, Lock, ControlValue2 Bytes9.21 current (mA)CW
117B Override 3, Central Control, ControlValue2 Bytes9.21 current (mA)CW
117B Override 3, User-defined Control, Control ValueValue2 Bytes9.21 current (mA)CW
117B Override 3, Permanent OFF, Control ValueValue2 Bytes9.24 power (kW)CW
117B Override 3, Manual ON, Control ValueValue2 Bytes9.24 power (kW)CW
117B Override 3, Lock, ControlValue2 Bytes9.24 power (kW)CW
117B Override 3, Central Control, ControlValue2 Bytes9.24 power (kW)CW
117B Override 3, User-defined Control, Control ValueValue2 Bytes9.24 power (kW)CW
117B Override 3, Permanent OFF, Control ValueValue4 Bytes14.56 power (W)CW
117B Override 3, Manual ON, Control ValueValue4 Bytes14.56 power (W)CW
117B Override 3, Lock, ControlValue4 Bytes14.56 power (W)CW
117B Override 3, Central Control, ControlValue4 Bytes14.56 power (W)CW
117B Override 3, User-defined Control, Control ValueValue4 Bytes14.56 power (W)CW
118B Override 3, Forced ControlOn / Off2 Bit2.1 switch controlCW
119B Override 3, Permanent-OFF, StatusOn / Off1 Bit1.2 booleanCRT
119B Override 3, Manual ON, StatusOn / Off1 Bit1.2 booleanCRT
119B Override 3, Lock, StatusOn / Off1 Bit1.2 booleanCRT
119B Override 3, Central Control, StatusOn / Off1 Bit1.2 booleanCRT
119B Override 3, User-defined Control, StatusOn / Off1 Bit1.2 booleanCRT
119B Override 3, Forced Control, StatusOn / Off1 Bit1.2 booleanCRT
120B Override 4, Permanent OFFOn / Off1 Bit1.3 enableCW
120B Override 4, Manual ONOn / Off1 Bit1.3 enableCW
120B Override 4, LockOn / Off1 Bit1.3 enableCW
120B Override 4, Central ControlOn / Off1 Bit1.3 enableCW
120B Override 4, User-defined ControlOn / Off1 Bit1.3 enableCW
121B Override 4, Permanent OFF, Control ValueValue1 Byte5.10 counter pulses (0..255)CW
121B Override 4, Manual ON, Control ValueValue1 Byte5.10 counter pulses (0..255)CW
121B Override 4, Lock, ControlValue1 Byte5.10 counter pulses (0..255)CW
121B Override 4, Central Control, ControlValue1 Byte5.10 counter pulses (0..255)CW
121B Override 4, User-defined Control, Control ValueValue1 Byte5.10 counter pulses (0..255)CW
121B Override 4, Permanent OFF, Control ValueValue2 Bytes9.1 temperature (°C)CW
121B Override 4, Manual ON, Control ValueValue2 Bytes9.1 temperature (°C)CW
121B Override 4, Lock, ControlValue2 Bytes9.1 temperature (°C)CW
121B Override 4, Central Control, ControlValue2 Bytes9.1 temperature (°C)CW
121B Override 4, User-defined Control, Control ValueValue2 Bytes9.1 temperature (°C)CW
121B Override 4, Permanent OFF, Control ValueValue1 Byte5.1 percentage (0..100%)CW
121B Override 4, Manual ON, Control ValueValue1 Byte5.1 percentage (0..100%)CW
121B Override 4, Lock, ControlValue1 Byte5.1 percentage (0..100%)CW
121B Override 4, Central Control, ControlValue1 Byte5.1 percentage (0..100%)CW
121B Override 4, User-defined Control, Control ValueValue1 Byte5.1 percentage (0..100%)CW
121B Override 4, Permanent OFF, Control ValueValue2 Bytes9.4 lux (Lux)CW
121B Override 4, Manual ON, Control ValueValue2 Bytes9.4 lux (Lux)CW
121B Override 4, Lock, ControlValue2 Bytes9.4 lux (Lux)CW
121B Override 4, Central Control, ControlValue2 Bytes9.4 lux (Lux)CW
121B Override 4, User-defined Control, Control ValueValue2 Bytes9.4 lux (Lux)CW
121B Override 4, Permanent OFF, Control ValueValue2 Bytes9.21 current (mA)CW
121B Override 4, Manual ON, Control ValueValue2 Bytes9.21 current (mA)CW
121B Override 4, Lock, ControlValue2 Bytes9.21 current (mA)CW
121B Override 4, Central Control, ControlValue2 Bytes9.21 current (mA)CW
121B Override 4, User-defined Control, Control ValueValue2 Bytes9.21 current (mA)CW
121B Override 4, Permanent OFF, Control ValueValue2 Bytes9.24 power (kW)CW
121B Override 4, Manual ON, Control ValueValue2 Bytes9.24 power (kW)CW
121B Override 4, Lock, ControlValue2 Bytes9.24 power (kW)CW
121B Override 4, Central Control, ControlValue2 Bytes9.24 power (kW)CW
121B Override 4, User-defined Control, Control ValueValue2 Bytes9.24 power (kW)CW
121B Override 4, Permanent OFF, Control ValueValue4 Bytes14.56 power (W)CW
121B Override 4, Manual ON, Control ValueValue4 Bytes14.56 power (W)CW
121B Override 4, Lock, ControlValue4 Bytes14.56 power (W)CW
121B Override 4, Central Control, ControlValue4 Bytes14.56 power (W)CW
121B Override 4, User-defined Control, Control ValueValue4 Bytes14.56 power (W)CW
122B Override 4, Forced ControlOn / Off2 Bit2.1 switch controlCW
123B Override 4, Permanent-OFF, StatusOn / Off1 Bit1.2 booleanCRT
123B Override 4, Manual ON, StatusOn / Off1 Bit1.2 booleanCRT
123B Override 4, Lock, StatusOn / Off1 Bit1.2 booleanCRT
123B Override 4, Central Control, StatusOn / Off1 Bit1.2 booleanCRT
123B Override 4, User-defined Control, StatusOn / Off1 Bit1.2 booleanCRT
123B Override 4, Forced Control, StatusOn / Off1 Bit1.2 booleanCRT
124B Override 5, Permanent OFFOn / Off1 Bit1.3 enableCW
124B Override 5, Manual ONOn / Off1 Bit1.3 enableCW
124B Override 5, LockOn / Off1 Bit1.3 enableCW
124B Override 5, Central ControlOn / Off1 Bit1.3 enableCW
124B Override 5, User-defined ControlOn / Off1 Bit1.3 enableCW
125B Override 5, Permanent OFF, Control ValueValue1 Byte5.10 counter pulses (0..255)CW
125B Override 5, Manual ON, Control ValueValue1 Byte5.10 counter pulses (0..255)CW
125B Override 5, Lock, ControlValue1 Byte5.10 counter pulses (0..255)CW
125B Override 5, Central Control, ControlValue1 Byte5.10 counter pulses (0..255)CW
125B Override 5, User-defined Control, Control ValueValue1 Byte5.10 counter pulses (0..255)CW
125B Override 5, Permanent OFF, Control ValueValue2 Bytes9.1 temperature (°C)CW
125B Override 5, Manual ON, Control ValueValue2 Bytes9.1 temperature (°C)CW
125B Override 5, Lock, ControlValue2 Bytes9.1 temperature (°C)CW
125B Override 5, Central Control, ControlValue2 Bytes9.1 temperature (°C)CW
125B Override 5, User-defined Control, Control ValueValue2 Bytes9.1 temperature (°C)CW
125B Override 5, Permanent OFF, Control ValueValue1 Byte5.1 percentage (0..100%)CW
125B Override 5, Manual ON, Control ValueValue1 Byte5.1 percentage (0..100%)CW
125B Override 5, Lock, ControlValue1 Byte5.1 percentage (0..100%)CW
125B Override 5, Central Control, ControlValue1 Byte5.1 percentage (0..100%)CW
125B Override 5, User-defined Control, Control ValueValue1 Byte5.1 percentage (0..100%)CW
125B Override 5, Permanent OFF, Control ValueValue2 Bytes9.4 lux (Lux)CW
125B Override 5, Manual ON, Control ValueValue2 Bytes9.4 lux (Lux)CW
125B Override 5, Lock, ControlValue2 Bytes9.4 lux (Lux)CW
125B Override 5, Central Control, ControlValue2 Bytes9.4 lux (Lux)CW
125B Override 5, User-defined Control, Control ValueValue2 Bytes9.4 lux (Lux)CW
125B Override 5, Permanent OFF, Control ValueValue2 Bytes9.21 current (mA)CW
125B Override 5, Manual ON, Control ValueValue2 Bytes9.21 current (mA)CW
125B Override 5, Lock, ControlValue2 Bytes9.21 current (mA)CW
125B Override 5, Central Control, ControlValue2 Bytes9.21 current (mA)CW
125B Override 5, User-defined Control, Control ValueValue2 Bytes9.21 current (mA)CW
125B Override 5, Permanent OFF, Control ValueValue2 Bytes9.24 power (kW)CW
125B Override 5, Manual ON, Control ValueValue2 Bytes9.24 power (kW)CW
125B Override 5, Lock, ControlValue2 Bytes9.24 power (kW)CW
125B Override 5, Central Control, ControlValue2 Bytes9.24 power (kW)CW
125B Override 5, User-defined Control, Control ValueValue2 Bytes9.24 power (kW)CW
125B Override 5, Permanent OFF, Control ValueValue4 Bytes14.56 power (W)CW
125B Override 5, Manual ON, Control ValueValue4 Bytes14.56 power (W)CW
125B Override 5, Lock, ControlValue4 Bytes14.56 power (W)CW
125B Override 5, Central Control, ControlValue4 Bytes14.56 power (W)CW
125B Override 5, User-defined Control, Control ValueValue4 Bytes14.56 power (W)CW
126B Override 5, Forced ControlOn / Off2 Bit2.1 switch controlCW
127B Override 5, Permanent-OFF, StatusOn / Off1 Bit1.2 booleanCRT
127B Override 5, Manual ON, StatusOn / Off1 Bit1.2 booleanCRT
127B Override 5, Lock, StatusOn / Off1 Bit1.2 booleanCRT
127B Override 5, Central Control, StatusOn / Off1 Bit1.2 booleanCRT
127B Override 5, User-defined Control, StatusOn / Off1 Bit1.2 booleanCRT
127B Override 5, Forced Control, StatusOn / Off1 Bit1.2 booleanCRT
128B Override 6, Permanent OFFOn / Off1 Bit1.3 enableCW
128B Override 6, Manual ONOn / Off1 Bit1.3 enableCW
128B Override 6, LockOn / Off1 Bit1.3 enableCW
128B Override 6, Central ControlOn / Off1 Bit1.3 enableCW
128B Override 6, User-defined ControlOn / Off1 Bit1.3 enableCW
129B Override 6, Permanent OFF, Control ValueValue1 Byte5.10 counter pulses (0..255)CW
129B Override 6, Manual ON, Control ValueValue1 Byte5.10 counter pulses (0..255)CW
129B Override 6, Lock, ControlValue1 Byte5.10 counter pulses (0..255)CW
129B Override 6, Central Control, ControlValue1 Byte5.10 counter pulses (0..255)CW
129B Override 6, User-defined Control, Control ValueValue1 Byte5.10 counter pulses (0..255)CW
129B Override 6, Permanent OFF, Control ValueValue2 Bytes9.1 temperature (°C)CW
129B Override 6, Manual ON, Control ValueValue2 Bytes9.1 temperature (°C)CW
129B Override 6, Lock, ControlValue2 Bytes9.1 temperature (°C)CW
129B Override 6, Central Control, ControlValue2 Bytes9.1 temperature (°C)CW
129B Override 6, User-defined Control, Control ValueValue2 Bytes9.1 temperature (°C)CW
129B Override 6, Permanent OFF, Control ValueValue1 Byte5.1 percentage (0..100%)CW
129B Override 6, Manual ON, Control ValueValue1 Byte5.1 percentage (0..100%)CW
129B Override 6, Lock, ControlValue1 Byte5.1 percentage (0..100%)CW
129B Override 6, Central Control, ControlValue1 Byte5.1 percentage (0..100%)CW
129B Override 6, User-defined Control, Control ValueValue1 Byte5.1 percentage (0..100%)CW
129B Override 6, Permanent OFF, Control ValueValue2 Bytes9.4 lux (Lux)CW
129B Override 6, Manual ON, Control ValueValue2 Bytes9.4 lux (Lux)CW
129B Override 6, Lock, ControlValue2 Bytes9.4 lux (Lux)CW
129B Override 6, Central Control, ControlValue2 Bytes9.4 lux (Lux)CW
129B Override 6, User-defined Control, Control ValueValue2 Bytes9.4 lux (Lux)CW
129B Override 6, Permanent OFF, Control ValueValue2 Bytes9.21 current (mA)CW
129B Override 6, Manual ON, Control ValueValue2 Bytes9.21 current (mA)CW
129B Override 6, Lock, ControlValue2 Bytes9.21 current (mA)CW
129B Override 6, Central Control, ControlValue2 Bytes9.21 current (mA)CW
129B Override 6, User-defined Control, Control ValueValue2 Bytes9.21 current (mA)CW
129B Override 6, Permanent OFF, Control ValueValue2 Bytes9.24 power (kW)CW
129B Override 6, Manual ON, Control ValueValue2 Bytes9.24 power (kW)CW
129B Override 6, Lock, ControlValue2 Bytes9.24 power (kW)CW
129B Override 6, Central Control, ControlValue2 Bytes9.24 power (kW)CW
129B Override 6, User-defined Control, Control ValueValue2 Bytes9.24 power (kW)CW
129B Override 6, Permanent OFF, Control ValueValue4 Bytes14.56 power (W)CW
129B Override 6, Manual ON, Control ValueValue4 Bytes14.56 power (W)CW
129B Override 6, Lock, ControlValue4 Bytes14.56 power (W)CW
129B Override 6, Central Control, ControlValue4 Bytes14.56 power (W)CW
129B Override 6, User-defined Control, Control ValueValue4 Bytes14.56 power (W)CW
130B Override 6, Forced ControlOn / Off2 Bit2.1 switch controlCW
131B Override 6, Permanent-OFF, StatusOn / Off1 Bit1.2 booleanCRT
131B Override 6, Manual ON, StatusOn / Off1 Bit1.2 booleanCRT
131B Override 6, Lock, StatusOn / Off1 Bit1.2 booleanCRT
131B Override 6, Central Control, StatusOn / Off1 Bit1.2 booleanCRT
131B Override 6, User-defined Control, StatusOn / Off1 Bit1.2 booleanCRT
131B Override 6, Forced Control, StatusOn / Off1 Bit1.2 booleanCRT
132B Override 7, Permanent OFFOn / Off1 Bit1.3 enableCW
132B Override 7, Manual ONOn / Off1 Bit1.3 enableCW
132B Override 7, LockOn / Off1 Bit1.3 enableCW
132B Override 7, Central ControlOn / Off1 Bit1.3 enableCW
132B Override 7, User-defined ControlOn / Off1 Bit1.3 enableCW
133B Override 7, Permanent OFF, Control ValueValue1 Byte5.10 counter pulses (0..255)CW
133B Override 7, Manual ON, Control ValueValue1 Byte5.10 counter pulses (0..255)CW
133B Override 7, Lock, ControlValue1 Byte5.10 counter pulses (0..255)CW
133B Override 7, Central Control, ControlValue1 Byte5.10 counter pulses (0..255)CW
133B Override 7, User-defined Control, Control ValueValue1 Byte5.10 counter pulses (0..255)CW
133B Override 7, Permanent OFF, Control ValueValue2 Bytes9.1 temperature (°C)CW
133B Override 7, Manual ON, Control ValueValue2 Bytes9.1 temperature (°C)CW
133B Override 7, Lock, ControlValue2 Bytes9.1 temperature (°C)CW
133B Override 7, Central Control, ControlValue2 Bytes9.1 temperature (°C)CW
133B Override 7, User-defined Control, Control ValueValue2 Bytes9.1 temperature (°C)CW
133B Override 7, Permanent OFF, Control ValueValue1 Byte5.1 percentage (0..100%)CW
133B Override 7, Manual ON, Control ValueValue1 Byte5.1 percentage (0..100%)CW
133B Override 7, Lock, ControlValue1 Byte5.1 percentage (0..100%)CW
133B Override 7, Central Control, ControlValue1 Byte5.1 percentage (0..100%)CW
133B Override 7, User-defined Control, Control ValueValue1 Byte5.1 percentage (0..100%)CW
133B Override 7, Permanent OFF, Control ValueValue2 Bytes9.4 lux (Lux)CW
133B Override 7, Manual ON, Control ValueValue2 Bytes9.4 lux (Lux)CW
133B Override 7, Lock, ControlValue2 Bytes9.4 lux (Lux)CW
133B Override 7, Central Control, ControlValue2 Bytes9.4 lux (Lux)CW
133B Override 7, User-defined Control, Control ValueValue2 Bytes9.4 lux (Lux)CW
133B Override 7, Permanent OFF, Control ValueValue2 Bytes9.21 current (mA)CW
133B Override 7, Manual ON, Control ValueValue2 Bytes9.21 current (mA)CW
133B Override 7, Lock, ControlValue2 Bytes9.21 current (mA)CW
133B Override 7, Central Control, ControlValue2 Bytes9.21 current (mA)CW
133B Override 7, User-defined Control, Control ValueValue2 Bytes9.21 current (mA)CW
133B Override 7, Permanent OFF, Control ValueValue2 Bytes9.24 power (kW)CW
133B Override 7, Manual ON, Control ValueValue2 Bytes9.24 power (kW)CW
133B Override 7, Lock, ControlValue2 Bytes9.24 power (kW)CW
133B Override 7, Central Control, ControlValue2 Bytes9.24 power (kW)CW
133B Override 7, User-defined Control, Control ValueValue2 Bytes9.24 power (kW)CW
133B Override 7, Permanent OFF, Control ValueValue4 Bytes14.56 power (W)CW
133B Override 7, Manual ON, Control ValueValue4 Bytes14.56 power (W)CW
133B Override 7, Lock, ControlValue4 Bytes14.56 power (W)CW
133B Override 7, Central Control, ControlValue4 Bytes14.56 power (W)CW
133B Override 7, User-defined Control, Control ValueValue4 Bytes14.56 power (W)CW
134B Override 7, Forced ControlOn / Off2 Bit2.1 switch controlCW
135B Override 7, Permanent-OFF, StatusOn / Off1 Bit1.2 booleanCRT
135B Override 7, Manual ON, StatusOn / Off1 Bit1.2 booleanCRT
135B Override 7, Lock, StatusOn / Off1 Bit1.2 booleanCRT
135B Override 7, Central Control, StatusOn / Off1 Bit1.2 booleanCRT
135B Override 7, User-defined Control, StatusOn / Off1 Bit1.2 booleanCRT
135B Override 7, Forced Control, StatusOn / Off1 Bit1.2 booleanCRT
136B Overrides status1 = Active1 Bit1.2 booleanCRT
137B Global dimming max. limit8 bit value1 Byte5.1 percentage (0..100%)CW
138B Direct operation lockOn / Off1 Bit1.3 enableCW
139B Status direct operationOn / Off1 Bit1.2 booleanCRT
140dummydummy2 BytesCRT
141dummydummy1 Byte21.601 lighting actuator error informationCRT
142B Number of switching cyclesValue (in cycles)4 Bytes12.1 counter pulses (unsigned)CRT
143B Number for switching cyclesSet Value (in cycles)4 Bytes12.1 counter pulses (unsigned)CW
144B Threshold for switching cyclesSet / Request Value (in cycles)4 Bytes12.1 counter pulses (unsigned)CRW
145B Exceedance of threshold for switching cyclesOn / Off1 Bit1.2 booleanCRT
146B Operating hoursValue (in hours)4 Bytes12.1 counter pulses (unsigned)CRT
147B Operating hoursValue (in seconds)4 Bytes13.100 time lag (s)CRT
148B Operating hoursSet Value4 Bytes12.1 counter pulses (unsigned)CW
149B Threshold for operating hoursSet / Request Value4 Bytes12.1 counter pulses (unsigned)CRW
150B Exceedance of threshold for operating hoursOn / Off1 Bit1.2 booleanCRT
151B Load Check-measured valueCurrent (mA)2 Bytes7.12 current (mA)CRT
152B Load Check-measured valueCurrent (A)4 Bytes14.19 electric current (A)CRT
153B Load Check-Normal value storeOn1 Bit1.3 enableCW
154B Load Check-Normal value recallCurrent (mA)2 Bytes7.12 current (mA)CRT
155B Load Check-Normal value recallCurrent (A)4 Bytes14.19 electric current (A)CRT
156B Load Check-Exceedance of load check limit valueOn / Off1 Bit1.2 booleanCRT
157B Load Check-Shortfall of load check limit valueOn / Off1 Bit1.2 booleanCRT
158B Load Check-Contact FailureOn / Off1 Bit1.2 booleanCRT
159B Dimming value8-bit value1 Byte5.1 percentage (0..100%)CW
160B Dimming value / timeDimming value + time3 BytesCW
161C SwitchingOn / Off1 Bit1.1 switchCW
162C Control ValueValue1 Byte5.10 counter pulses (0..255)CW
162C Control ValueValue2 Bytes9.1 temperature (°C)CW
162C Control ValueValue1 Byte5.1 percentage (0..100%)CW
162C Control ValueValue2 Bytes9.4 lux (Lux)CW
162C Control ValueValue2 Bytes9.21 current (mA)CW
162C Control ValueValue2 Bytes9.24 power (kW)CW
162C Control ValueValue4 Bytes14.56 power (W)CW
163C DimmingBrighter / darker4 Bit3.7 dimming controlCW
164C Dimming value 18-bit value1 Byte5.1 percentage (0..100%)CW
165C Dimming value 28-bit value1 Byte5.1 percentage (0..100%)CW
166C Dimming value 1 / timeDimming value + time3 BytesCW
167C Dimming value 1 / timeDimming value + time3 BytesCW
168C Status switchingOn / Off1 Bit1.1 switchCRT
169C Status dimming value8-bit value1 Byte5.1 percentage (0..100%)CRT
170C Minimum dimming valueSet / Request Value1 Byte5.1 percentage (0..100%)CRW
171C Maximum dimming valueSet / Request Value1 Byte5.1 percentage (0..100%)CRW
172C Dimming time for switchingSet / Request dimming time2 Bytes7.4 time (100 ms)CRW
173C Dimming time for dimmingSet / Request dimming time2 Bytes7.4 time (100 ms)CRW
174C Dimming time for dimming value 1Set / Request dimming time2 Bytes7.4 time (100 ms)CRW
175C Dimming time for dimming value 2Set / Request dimming time2 Bytes7.4 time (100 ms)CRW
176C Logic operation 1On / Off1 Bit1.1 switchCW
177C Logic operation 2On / Off1 Bit1.1 switchCW
178C Central SwitchingOn / Off1 Bit1.1 switchCW
179C 8-bit scenerecall / store 1 Byte18.1 scene controlCW
180C Scene value/timeValue / Time3 BytesCW
181C Night modeOn / Off1 Bit1.3 enableCW
182C Night mode timerON time (seconds)2 Bytes7.5 time (s)CRW
183C Day mode timerON time 1 (seconds)2 Bytes7.5 time (s)CRW
184C Forced controlOn / Off2 Bit2.1 switch controlCW
185C Pre-warning expiration of timer periodOn / Off1 Bit1.1 switchCRT
186C Lock TimerOn / Off1 Bit1.3 enableCW
187C Override 1, Permanent OFFOn / Off1 Bit1.3 enableCW
187C Override 1, Manual ONOn / Off1 Bit1.3 enableCW
187C Override 1, LockOn / Off1 Bit1.3 enableCW
187C Override 1, Central ControlOn / Off1 Bit1.3 enableCW
187C Override 1, User-defined ControlOn / Off1 Bit1.3 enableCW
188C Override 1, Permanent OFF, Control ValueValue1 Byte5.10 counter pulses (0..255)CW
188C Override 1, Manual ON, Control ValueValue1 Byte5.10 counter pulses (0..255)CW
188C Override 1, Lock, ControlValue1 Byte5.10 counter pulses (0..255)CW
188C Override 1, Central Control, ControlValue1 Byte5.10 counter pulses (0..255)CW
188C Override 1, User-defined Control, Control ValueValue1 Byte5.10 counter pulses (0..255)CW
188C Override 1, Permanent OFF, Control ValueValue2 Bytes9.1 temperature (°C)CW
188C Override 1, Manual ON, Control ValueValue2 Bytes9.1 temperature (°C)CW
188C Override 1, Lock, ControlValue2 Bytes9.1 temperature (°C)CW
188C Override 1, Central Control, ControlValue2 Bytes9.1 temperature (°C)CW
188C Override 1, User-defined Control, Control ValueValue2 Bytes9.1 temperature (°C)CW
188C Override 1, Permanent OFF, Control ValueValue1 Byte5.1 percentage (0..100%)CW
188C Override 1, Manual ON, Control ValueValue1 Byte5.1 percentage (0..100%)CW
188C Override 1, Lock, ControlValue1 Byte5.1 percentage (0..100%)CW
188C Override 1, Central Control, ControlValue1 Byte5.1 percentage (0..100%)CW
188C Override 1, User-defined Control, Control ValueValue1 Byte5.1 percentage (0..100%)CW
188C Override 1, Permanent OFF, Control ValueValue2 Bytes9.4 lux (Lux)CW
188C Override 1, Manual ON, Control ValueValue2 Bytes9.4 lux (Lux)CW
188C Override 1, Lock, ControlValue2 Bytes9.4 lux (Lux)CW
188C Override 1, Central Control, ControlValue2 Bytes9.4 lux (Lux)CW
188C Override 1, User-defined Control, Control ValueValue2 Bytes9.4 lux (Lux)CW
188C Override 1, Permanent OFF, Control ValueValue2 Bytes9.21 current (mA)CW
188C Override 1, Manual ON, Control ValueValue2 Bytes9.21 current (mA)CW
188C Override 1, Lock, ControlValue2 Bytes9.21 current (mA)CW
188C Override 1, Central Control, ControlValue2 Bytes9.21 current (mA)CW
188C Override 1, User-defined Control, Control ValueValue2 Bytes9.21 current (mA)CW
188C Override 1, Permanent OFF, Control ValueValue2 Bytes9.24 power (kW)CW
188C Override 1, Manual ON, Control ValueValue2 Bytes9.24 power (kW)CW
188C Override 1, Lock, ControlValue2 Bytes9.24 power (kW)CW
188C Override 1, Central Control, ControlValue2 Bytes9.24 power (kW)CW
188C Override 1, User-defined Control, Control ValueValue2 Bytes9.24 power (kW)CW
188C Override 1, Permanent OFF, Control ValueValue4 Bytes14.56 power (W)CW
188C Override 1, Manual ON, Control ValueValue4 Bytes14.56 power (W)CW
188C Override 1, Lock, ControlValue4 Bytes14.56 power (W)CW
188C Override 1, Central Control, ControlValue4 Bytes14.56 power (W)CW
188C Override 1, User-defined Control, Control ValueValue4 Bytes14.56 power (W)CW
189C Override 1, Forced ControlOn / Off2 Bit2.1 switch controlCW
190C Override 1, Permanent-OFF, StatusOn / Off1 Bit1.2 booleanCRT
190C Override 1, Manual ON, StatusOn / Off1 Bit1.2 booleanCRT
190C Override 1, Lock, StatusOn / Off1 Bit1.2 booleanCRT
190C Override 1, Central Control, StatusOn / Off1 Bit1.2 booleanCRT
190C Override 1, User-defined Control, StatusOn / Off1 Bit1.2 booleanCRT
190C Override 1, Forced Control, StatusOn / Off1 Bit1.2 booleanCRT
191C Override 2, Permanent OFFOn / Off1 Bit1.3 enableCW
191C Override 2, Manual ONOn / Off1 Bit1.3 enableCW
191C Override 2, LockOn / Off1 Bit1.3 enableCW
191C Override 2, Central ControlOn / Off1 Bit1.3 enableCW
191C Override 2, User-defined ControlOn / Off1 Bit1.3 enableCW
192C Override 2, Permanent OFF, Control ValueValue1 Byte5.10 counter pulses (0..255)CW
192C Override 2, Manual ON, Control ValueValue1 Byte5.10 counter pulses (0..255)CW
192C Override 2, Lock, ControlValue1 Byte5.10 counter pulses (0..255)CW
192C Override 2, Central Control, ControlValue1 Byte5.10 counter pulses (0..255)CW
192C Override 2, User-defined Control, Control ValueValue1 Byte5.10 counter pulses (0..255)CW
192C Override 2, Permanent OFF, Control ValueValue2 Bytes9.1 temperature (°C)CW
192C Override 2, Manual ON, Control ValueValue2 Bytes9.1 temperature (°C)CW
192C Override 2, Lock, ControlValue2 Bytes9.1 temperature (°C)CW
192C Override 2, Central Control, ControlValue2 Bytes9.1 temperature (°C)CW
192C Override 2, User-defined Control, Control ValueValue2 Bytes9.1 temperature (°C)CW
192C Override 2, Permanent OFF, Control ValueValue1 Byte5.1 percentage (0..100%)CW
192C Override 2, Manual ON, Control ValueValue1 Byte5.1 percentage (0..100%)CW
192C Override 2, Lock, ControlValue1 Byte5.1 percentage (0..100%)CW
192C Override 2, Central Control, ControlValue1 Byte5.1 percentage (0..100%)CW
192C Override 2, User-defined Control, Control ValueValue1 Byte5.1 percentage (0..100%)CW
192C Override 2, Permanent OFF, Control ValueValue2 Bytes9.4 lux (Lux)CW
192C Override 2, Manual ON, Control ValueValue2 Bytes9.4 lux (Lux)CW
192C Override 2, Lock, ControlValue2 Bytes9.4 lux (Lux)CW
192C Override 2, Central Control, ControlValue2 Bytes9.4 lux (Lux)CW
192C Override 2, User-defined Control, Control ValueValue2 Bytes9.4 lux (Lux)CW
192C Override 2, Permanent OFF, Control ValueValue2 Bytes9.21 current (mA)CW
192C Override 2, Manual ON, Control ValueValue2 Bytes9.21 current (mA)CW
192C Override 2, Lock, ControlValue2 Bytes9.21 current (mA)CW
192C Override 2, Central Control, ControlValue2 Bytes9.21 current (mA)CW
192C Override 2, User-defined Control, Control ValueValue2 Bytes9.21 current (mA)CW
192C Override 2, Permanent OFF, Control ValueValue2 Bytes9.24 power (kW)CW
192C Override 2, Manual ON, Control ValueValue2 Bytes9.24 power (kW)CW
192C Override 2, Lock, ControlValue2 Bytes9.24 power (kW)CW
192C Override 2, Central Control, ControlValue2 Bytes9.24 power (kW)CW
192C Override 2, User-defined Control, Control ValueValue2 Bytes9.24 power (kW)CW
192C Override 2, Permanent OFF, Control ValueValue4 Bytes14.56 power (W)CW
192C Override 2, Manual ON, Control ValueValue4 Bytes14.56 power (W)CW
192C Override 2, Lock, ControlValue4 Bytes14.56 power (W)CW
192C Override 2, Central Control, ControlValue4 Bytes14.56 power (W)CW
192C Override 2, User-defined Control, Control ValueValue4 Bytes14.56 power (W)CW
193C Override 2, Forced ControlOn / Off2 Bit2.1 switch controlCW
194C Override 2, Permanent-OFF, StatusOn / Off1 Bit1.2 booleanCRT
194C Override 2, Manual ON, StatusOn / Off1 Bit1.2 booleanCRT
194C Override 2, Lock, StatusOn / Off1 Bit1.2 booleanCRT
194C Override 2, Central Control, StatusOn / Off1 Bit1.2 booleanCRT
194C Override 2, User-defined Control, StatusOn / Off1 Bit1.2 booleanCRT
194C Override 2, Forced Control, StatusOn / Off1 Bit1.2 booleanCRT
195C Override 3, Permanent OFFOn / Off1 Bit1.3 enableCW
195C Override 3, Manual ONOn / Off1 Bit1.3 enableCW
195C Override 3, LockOn / Off1 Bit1.3 enableCW
195C Override 3, Central ControlOn / Off1 Bit1.3 enableCW
195C Override 3, User-defined ControlOn / Off1 Bit1.3 enableCW
196C Override 3, Permanent OFF, Control ValueValue1 Byte5.10 counter pulses (0..255)CW
196C Override 3, Manual ON, Control ValueValue1 Byte5.10 counter pulses (0..255)CW
196C Override 3, Lock, ControlValue1 Byte5.10 counter pulses (0..255)CW
196C Override 3, Central Control, ControlValue1 Byte5.10 counter pulses (0..255)CW
196C Override 3, User-defined Control, Control ValueValue1 Byte5.10 counter pulses (0..255)CW
196C Override 3, Permanent OFF, Control ValueValue2 Bytes9.1 temperature (°C)CW
196C Override 3, Manual ON, Control ValueValue2 Bytes9.1 temperature (°C)CW
196C Override 3, Lock, ControlValue2 Bytes9.1 temperature (°C)CW
196C Override 3, Central Control, ControlValue2 Bytes9.1 temperature (°C)CW
196C Override 3, User-defined Control, Control ValueValue2 Bytes9.1 temperature (°C)CW
196C Override 3, Permanent OFF, Control ValueValue1 Byte5.1 percentage (0..100%)CW
196C Override 3, Manual ON, Control ValueValue1 Byte5.1 percentage (0..100%)CW
196C Override 3, Lock, ControlValue1 Byte5.1 percentage (0..100%)CW
196C Override 3, Central Control, ControlValue1 Byte5.1 percentage (0..100%)CW
196C Override 3, User-defined Control, Control ValueValue1 Byte5.1 percentage (0..100%)CW
196C Override 3, Permanent OFF, Control ValueValue2 Bytes9.4 lux (Lux)CW
196C Override 3, Manual ON, Control ValueValue2 Bytes9.4 lux (Lux)CW
196C Override 3, Lock, ControlValue2 Bytes9.4 lux (Lux)CW
196C Override 3, Central Control, ControlValue2 Bytes9.4 lux (Lux)CW
196C Override 3, User-defined Control, Control ValueValue2 Bytes9.4 lux (Lux)CW
196C Override 3, Permanent OFF, Control ValueValue2 Bytes9.21 current (mA)CW
196C Override 3, Manual ON, Control ValueValue2 Bytes9.21 current (mA)CW
196C Override 3, Lock, ControlValue2 Bytes9.21 current (mA)CW
196C Override 3, Central Control, ControlValue2 Bytes9.21 current (mA)CW
196C Override 3, User-defined Control, Control ValueValue2 Bytes9.21 current (mA)CW
196C Override 3, Permanent OFF, Control ValueValue2 Bytes9.24 power (kW)CW
196C Override 3, Manual ON, Control ValueValue2 Bytes9.24 power (kW)CW
196C Override 3, Lock, ControlValue2 Bytes9.24 power (kW)CW
196C Override 3, Central Control, ControlValue2 Bytes9.24 power (kW)CW
196C Override 3, User-defined Control, Control ValueValue2 Bytes9.24 power (kW)CW
196C Override 3, Permanent OFF, Control ValueValue4 Bytes14.56 power (W)CW
196C Override 3, Manual ON, Control ValueValue4 Bytes14.56 power (W)CW
196C Override 3, Lock, ControlValue4 Bytes14.56 power (W)CW
196C Override 3, Central Control, ControlValue4 Bytes14.56 power (W)CW
196C Override 3, User-defined Control, Control ValueValue4 Bytes14.56 power (W)CW
197C Override 3, Forced ControlOn / Off2 Bit2.1 switch controlCW
198C Override 3, Permanent-OFF, StatusOn / Off1 Bit1.2 booleanCRT
198C Override 3, Manual ON, StatusOn / Off1 Bit1.2 booleanCRT
198C Override 3, Lock, StatusOn / Off1 Bit1.2 booleanCRT
198C Override 3, Central Control, StatusOn / Off1 Bit1.2 booleanCRT
198C Override 3, User-defined Control, StatusOn / Off1 Bit1.2 booleanCRT
198C Override 3, Forced Control, StatusOn / Off1 Bit1.2 booleanCRT
199C Override 4, Permanent OFFOn / Off1 Bit1.3 enableCW
199C Override 4, Manual ONOn / Off1 Bit1.3 enableCW
199C Override 4, LockOn / Off1 Bit1.3 enableCW
199C Override 4, Central ControlOn / Off1 Bit1.3 enableCW
199C Override 4, User-defined ControlOn / Off1 Bit1.3 enableCW
200C Override 4, Permanent OFF, Control ValueValue1 Byte5.10 counter pulses (0..255)CW
200C Override 4, Manual ON, Control ValueValue1 Byte5.10 counter pulses (0..255)CW
200C Override 4, Lock, ControlValue1 Byte5.10 counter pulses (0..255)CW
200C Override 4, Central Control, ControlValue1 Byte5.10 counter pulses (0..255)CW
200C Override 4, User-defined Control, Control ValueValue1 Byte5.10 counter pulses (0..255)CW
200C Override 4, Permanent OFF, Control ValueValue2 Bytes9.1 temperature (°C)CW
200C Override 4, Manual ON, Control ValueValue2 Bytes9.1 temperature (°C)CW
200C Override 4, Lock, ControlValue2 Bytes9.1 temperature (°C)CW
200C Override 4, Central Control, ControlValue2 Bytes9.1 temperature (°C)CW
200C Override 4, User-defined Control, Control ValueValue2 Bytes9.1 temperature (°C)CW
200C Override 4, Permanent OFF, Control ValueValue1 Byte5.1 percentage (0..100%)CW
200C Override 4, Manual ON, Control ValueValue1 Byte5.1 percentage (0..100%)CW
200C Override 4, Lock, ControlValue1 Byte5.1 percentage (0..100%)CW
200C Override 4, Central Control, ControlValue1 Byte5.1 percentage (0..100%)CW
200C Override 4, User-defined Control, Control ValueValue1 Byte5.1 percentage (0..100%)CW
200C Override 4, Permanent OFF, Control ValueValue2 Bytes9.4 lux (Lux)CW
200C Override 4, Manual ON, Control ValueValue2 Bytes9.4 lux (Lux)CW
200C Override 4, Lock, ControlValue2 Bytes9.4 lux (Lux)CW
200C Override 4, Central Control, ControlValue2 Bytes9.4 lux (Lux)CW
200C Override 4, User-defined Control, Control ValueValue2 Bytes9.4 lux (Lux)CW
200C Override 4, Permanent OFF, Control ValueValue2 Bytes9.21 current (mA)CW
200C Override 4, Manual ON, Control ValueValue2 Bytes9.21 current (mA)CW
200C Override 4, Lock, ControlValue2 Bytes9.21 current (mA)CW
200C Override 4, Central Control, ControlValue2 Bytes9.21 current (mA)CW
200C Override 4, User-defined Control, Control ValueValue2 Bytes9.21 current (mA)CW
200C Override 4, Permanent OFF, Control ValueValue2 Bytes9.24 power (kW)CW
200C Override 4, Manual ON, Control ValueValue2 Bytes9.24 power (kW)CW
200C Override 4, Lock, ControlValue2 Bytes9.24 power (kW)CW
200C Override 4, Central Control, ControlValue2 Bytes9.24 power (kW)CW
200C Override 4, User-defined Control, Control ValueValue2 Bytes9.24 power (kW)CW
200C Override 4, Permanent OFF, Control ValueValue4 Bytes14.56 power (W)CW
200C Override 4, Manual ON, Control ValueValue4 Bytes14.56 power (W)CW
200C Override 4, Lock, ControlValue4 Bytes14.56 power (W)CW
200C Override 4, Central Control, ControlValue4 Bytes14.56 power (W)CW
200C Override 4, User-defined Control, Control ValueValue4 Bytes14.56 power (W)CW
201C Override 4, Forced ControlOn / Off2 Bit2.1 switch controlCW
202C Override 4, Permanent-OFF, StatusOn / Off1 Bit1.2 booleanCRT
202C Override 4, Manual ON, StatusOn / Off1 Bit1.2 booleanCRT
202C Override 4, Lock, StatusOn / Off1 Bit1.2 booleanCRT
202C Override 4, Central Control, StatusOn / Off1 Bit1.2 booleanCRT
202C Override 4, User-defined Control, StatusOn / Off1 Bit1.2 booleanCRT
202C Override 4, Forced Control, StatusOn / Off1 Bit1.2 booleanCRT
203C Override 5, Permanent OFFOn / Off1 Bit1.3 enableCW
203C Override 5, Manual ONOn / Off1 Bit1.3 enableCW
203C Override 5, LockOn / Off1 Bit1.3 enableCW
203C Override 5, Central ControlOn / Off1 Bit1.3 enableCW
203C Override 5, User-defined ControlOn / Off1 Bit1.3 enableCW
204C Override 5, Permanent OFF, Control ValueValue1 Byte5.10 counter pulses (0..255)CW

First 1000 of 3090 group objects shown. Download the .knxprod for the full list.

Parameters (202)
ParameterTypeDefault
Cyclical transmission of device function (0=in operation)listEnable
Send status of device function inverted (1=in operation)listNo
Cyclical transmission periodtime120
Specific transmission time for status objects after bus voltage recoverytime15
Transmission delay between status objectstime1
Behaviour after downloadlistUse device parameter
Function Channel AlistDimming
Function Channel BlistDimming
Function Channel ClistDimming
Function Channel DlistDimming
Function Channel ElistDimming
Function Channel FlistDimming
Function Channel GlistDimming
Function Channel HlistDimming
Current unitlistA
Load Check monitoringlistNo
Dead timetime0
Load Check offset below limit (mA)unsignedInt 0…6553515
Load Check offset above limit (mA)unsignedInt 0…6553515
Load Check hysteresis below limit (mA)unsignedInt 0…25526
Load Check hysteresis above limit (mA)unsignedInt 0…25526
Load Check hysteresis below limit (%)unsignedInt 0…10010
Load Check hysteresis above limit (%)unsignedInt 0…10010
not_visiblelistLast value
Last variantlistdummy
ON time 2 during day modetime900
Warning before switching OfflistNo
8-bit scenes configurable by userlistDisable
Load ChecklistDisable
dummylistDeactivate timer
Limit night mode timerlistEnable
Two dimming valueslistDisable
Show dimming value/time objectlistDisable
dummylistEnable
dummylistDisable
dummytime0
Measure if load current flowlistDisable
Load Check normal value (mA)unsignedInt 0…65535150
Normal value recalllistDisable
Send status on change of statuslistDisable
Value change since last sent (mA)unsignedInt 0…655350
Send status on requestlistDisable
Send status cyclicallytime0
Exceedance of load check limit valuelistDisable
Shortfall of load check imit valuelistDisable
Load Check measured valuelistDisable
Value change since last sent (mA)unsignedInt 0…655353
Contact FailurelistDisable
Override 1listDeactivated
enablelistDisable
Start value / behavior of override input on bus voltage recoverylistDeactivated
Restart timer on deactivation of overridelistEnable
Behavior on override activationlistno change
Behavior on override deactivationlistupdated value
Value at activation (%)unsignedInt 0…255255
Value at deactivation (%)unsignedInt 0…2550
Power up value (%)listOn
Invert Override ControllistNo
Monitoring Timetime0
Override Durationtime0
Status OverridelistEnable
Override 2listDeactivated
Override 3listDeactivated
Override 4listDeactivated
Override 5listDeactivated
Override 6listDeactivated
Override 7listDeactivated
not_visiblelistFalse
Value: x1unsignedInt 0…2551
Value: y1unsignedInt 0…25521
Value: x2unsignedInt 0…255255
Value: y2unsignedInt 0…255223
Value: x3unsignedInt 0…2550
Value: y3unsignedInt 0…2550
Value: x4unsignedInt 0…2550
Value: y4unsignedInt 0…2550
Value: x5unsignedInt 0…2550
Value: y5unsignedInt 0…2550
Value: x6unsignedInt 0…2550
Value: y6unsignedInt 0…2550
Value: x7unsignedInt 0…2550
Value: y7unsignedInt 0…2550
Value: x8unsignedInt 0…2550
Value: y8unsignedInt 0…2550
Value: x9unsignedInt 0…2550
Value: y9unsignedInt 0…2550
Value: x10unsignedInt 0…2550
Value: y10unsignedInt 0…2550
Value: x11unsignedInt 0…2550
Value: y11unsignedInt 0…2550
Value: x12unsignedInt 0…2550
Value: y12unsignedInt 0…2550
Value: x13unsignedInt 0…2550
Value: y13unsignedInt 0…2550
Value: x14unsignedInt 0…2550
Value: y14unsignedInt 0…2550
Value: x15unsignedInt 0…2550
Value: y15unsignedInt 0…2550
Value: x16unsignedInt 0…2550
Value: y16unsignedInt 0…2550
Direct operationlistEnable
Direct operation auto resettime900
Direct operation lockablelistDisable
dummylistdummy
dummyunsignedInt 0…2551
Operation ModelistNormal mode
Control Value InputlistDisable
Central SwitchinglistDisable
8-bit scene controllistDisable
Overrides statuslistEnable
Send status on change of statuslistEnable
Status direct operationlistDisable
Status switchinglistEnable
Status dimming valuelistEnable
Value change since last sent (%)unsignedInt 0…1005
Value change since last sent (%)unsignedInt 0…25513
Minimum wait time between updatestime100
Switching state on bus voltage failurelistno change
Initial value after bus voltage recoverylistLast status of the dimming value
Dimming value at power recovery (%)unsignedInt 0…1000
Dimming value at power recovery (%)unsignedInt 0…2550
Counting of switching cycleslistDisable
Counting of operating hourslistDisable
Dimming curvelistLinear
Output voltage - minimum lamp power (V)list1,0 V
Output voltage - maximum lamp power (V)list10,0 V
Minimum dimming value (%)unsignedInt 0…1001
Minimum dimming value (%)unsignedInt 0…2553
Maximum dimming value (%)unsignedInt 0…100100
Maximum dimming valueunsignedInt 0…255255
Show min/max limitation objectslistDisable
Global dimming max. limitlistDisable
Dimming time for switchingtime0
Dimming time for dimmingtime50
Dimming time for dimming value 1time50
Dimming time for dimming value 2time50
Show dimming fade time objectslistDisable
Switch on at valuelistStart value according to parameter
Switch on value (%)unsignedInt 0…100100
Switch on value (%)unsignedInt 0…255255
Off via dimminglistEnable
On via dimminglistEnable
Switching via dimming value 1listOn and Off possible
Switching via dimming value 2listOn and Off possible
ON delaytime0
OFF delaytime0
ON delay (central switching)time0
OFF delay (central switching)time0
Night modelistDisable
ON time during night modetime1800
Retriggering possibleunsignedInt 0…51
Warning periodtime30
Warning signal periodtime1
Change ON time in night mode via objectlistDisable
Blocking characteritics for timer modelistDeactivate timer
ON time 1 during day modetime900
Dimming value during ON time 2 (%)unsignedInt 0…10050
dummyunsignedInt 0…255128
Warning signal periodtime2
Change ON 1 time during day mode via objectlistDisable
Number of flashing cycles (0 = indefinite)unsignedInt 0…100005
ON time flashingtime1
OFF time flashingtime1
Data TypelistPercentage (%) DPT 5.001
Threshold for Off (<=)unsignedInt 0…2550
Threshold for On (>=)unsignedInt 0…2551
Threshold for Off (<=)float -671088.6…670760.90
Threshold for On (>=)float -671088.6…670760.91
Threshold for On (>=)unsignedInt 0…2553
Threshold for Off (<=)unsignedInt 0…1000
Threshold for On (>=)unsignedInt 0…1001
Threshold for Off (<=)float -3.402823e+38…3.402823e+380
Threshold for On (>=)float -3.402823e+38…3.402823e+381
Logic operation 1listNo logic operation
Invert logical inputlistNo
Invert logical outputlistNo
Initial value of logic operation object after bus voltage recoverylistas before bus voltage failure
Logic operation 2listNo logic operation
Link 1 with scene [1…64] (0 = disable)unsignedInt 0…640
dummyunsignedInt 0…255192
Fade timetime0
Delete learned scenelistDisable
Predefine scenelistDisable
Predefined dimming value for scene (%)unsignedInt 0…100100
Predefined switching value for sceneunsignedInt 0…255255
Link 2 with scene [1…64] (0 = disable)unsignedInt 0…640
Link 3 with scene [1…64] (0 = disable)unsignedInt 0…640
Link 4 with scene [1…64] (0 = disable)unsignedInt 0…640
Link 5 with scene [1…64] (0 = disable)unsignedInt 0…640
Link 6 with scene [1…64] (0 = disable)unsignedInt 0…640
Link 7 with scene [1…64] (0 = disable)unsignedInt 0…640
Link 8 with scene [1…64] (0 = disable)unsignedInt 0…640
Control Value Input Data TypelistPercentage (%) DPT 5.001
Value at activation (%)unsignedInt 0…100100
Value at deactivation (%)unsignedInt 0…1000
Value change since last sent (cycles)unsignedInt 0…42949672951
Threshold monitoringlistDisable
Threshold for switching cyclesunsignedInt 0…42949672951000
Counting of operating hours inlisthours
Value change since last sent (hours)unsignedInt 0…42949672951
Value change since last sent (seconds)unsignedInt 0…42949672953600
Threshold for operating hoursunsignedInt 0…42949672951000

Version history

ApplicationApp noFingerprintFirst seenSizeFile
07 B0 A8 Switch-/Dimm actuator 8-fold 9A0602 0.2 latest$9A066F6C2026-11-251.5 MBDownload

About this file

This is the official ETS product database for the Siemens Switch-/Dimm actuator N 536D51, 8x AC 230 V, 1…10V (5WG1 536-1DB51), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.

More from Siemens

All Siemens products