RDG260KN Room Thermostat RDG260KN
Siemens HVAC · Order number RDG260KN · Heating, Ventilation, Air Conditioning › Room Thermostats
Room Thermostat Controller
Download .knxprod RDG260KN 2.0 · 215 KB
Product
| Manufacturer | Siemens HVAC |
|---|---|
| Product name | RDG260KN Room Thermostat |
| Order number | RDG260KN |
| Hardware | HardwareEntry.0.1102 |
| Medium | Twisted Pair |
| Bus current (mA) | 5 |
| Rail mounted | No |
| Registration | Certified · 2020-08-13 |
| Languages | de-DE, en-US, fr-FR |
| Catalog entry | M-00FD_H-RDG260KN-1_HP-1102-20-C65C_CI-RDG260KN-1 |
| Fingerprint | C65C |
| SHA-256 | d8bdf5cc409c466e1fc5e09cbd7c0f76fcc5de98f5be4463cf3e54bddc82a336 |
| First seen | 2026-11-25 |
| Markets | Russia |
Application program: RDG260KN 2.0
| Application number | $1102 |
|---|---|
| Version | 2.0 |
| Mask version | MV-07B0 (System B) |
| KNX Data Secure | No |
| Minimum ETS version | 5.0 |
| Parameters | 134 |
| Group objects | 99 |
Group objects (99)
| No | Name | Function | Size | DPT | Flags |
|---|---|---|---|---|---|
| 1 | System time | Receive | 8 Bytes | 19.1 date time | CWU |
| 2 | Date | Receive | 3 Bytes | 11.1 date | CWU |
| 3 | Time of day | Receive | 3 Bytes | 10.1 time of day | CWU |
| 4 | Fault information | Send | 6 Bytes | 219.1 alarm info | CRT |
| 5 | Fault state (0=Normal/1=Fault) | Send | 1 Bit | 1.5 alarm | CRT |
| 6 | Fault transmission (0=Disable/1=Enable) | Receive | 1 Bit | 1.3 enable | CWU |
| 7 | Room operating mode: Preselection | Receive | 1 Byte | 20.102 HVAC mode | CWU |
| 8 | Room operating mode: Preselection | Send | 1 Byte | 20.102 HVAC mode | CRT |
| 9 | Room operating mode: Preselection Auto | Receive | 1 Bit | 1.17 trigger | CW |
| 10 | Room operating mode: Preselection Comfort | Receive | 1 Bit | 1.17 trigger | CW |
| 11 | Room operating mode: Preselection Economy | Receive | 1 Bit | 1.17 trigger | CW |
| 12 | Room operating mode: Preselection Protection | Receive | 1 Bit | 1.17 trigger | CW |
| 13 | Room operating mode: Scheduler | Receive | 1 Byte | 20.102 HVAC mode | CWU |
| 14 | Room operating mode: Scheduler Comfort | Receive | 1 Bit | 1.17 trigger | CW |
| 15 | Room operating mode: Scheduler Economy | Receive | 1 Bit | 1.17 trigger | CW |
| 16 | Room operating mode: Scheduler Protection | Receive | 1 Bit | 1.17 trigger | CW |
| 17 | Room operating mode state | Send | 1 Byte | 20.102 HVAC mode | CRT |
| 18 | Room operating mode state: Comfort | Send | 1 Bit | 1.11 state | CRT |
| 19 | Room operating mode state: Economy | Send | 1 Bit | 1.11 state | CRT |
| 20 | Room operating mode state: Protection | Send | 1 Bit | 1.11 state | CRT |
| 21 | Room temp: [P19] Heating setpoint Economy | Receive | 2 Bytes | 9.1 temperature (°C) | CW |
| 22 | Room temp: [P20] Cooling setpoint Economy | Receive | 2 Bytes | 9.1 temperature (°C) | CW |
| 23 | Room operating mode: Window contact (0=Close/1=Open) | Receive | 1 Bit | 1.19 window/door | CWU |
| 24 | Room operating mode: Presence detector (0=Unoccupied/1=Occupied) | Receive | 1 Bit | 1.18 occupancy | CWU |
| 25 | Room temp: Basic setpoint Comfort | Receive | 2 Bytes | 9.1 temperature (°C) | CWU |
| 26 | Room temp: Abs. setpoint Comfort | Receive | 2 Bytes | 9.1 temperature (°C) | CWU |
| 27 | Room temp: Abs. setpoint Comfort | Send | 2 Bytes | 9.1 temperature (°C) | CRT |
| 28 | Room temp: Current setpoint | Send | 2 Bytes | 9.1 temperature (°C) | CRT |
| 29 | Setpoint heating set | Receive | 8 Bytes | 275.100 Temperature setpoint setting for 4 HVAC Modes | CW |
| 30 | Setpoint cooling set | Receive | 8 Bytes | 275.100 Temperature setpoint setting for 4 HVAC Modes | CW |
| 31 | Setpoint heating set | Send | 8 Bytes | 275.100 Temperature setpoint setting for 4 HVAC Modes | CRT |
| 32 | Setpoint cooling set | Send | 8 Bytes | 275.100 Temperature setpoint setting for 4 HVAC Modes | CRT |
| 33 | Room temperature: Rel. setpoint Comfort | Receive | 2 Bytes | 9.2 temperature difference (K) | CWU |
| 34 | Room temperature: Rel. setpoint Comfort | Send | 2 Bytes | 9.2 temperature difference (K) | CRT |
| 35 | Extended comfort mode state | Send | 1 Bit | 1.11 state | CRT |
| 36 | External room temperature value | Receive | 2 Bytes | 9.1 temperature (°C) | CWU |
| 37 | Built-in room temperature value | Send | 2 Bytes | 9.1 temperature (°C) | CRT |
| 38 | Frost alarm (0=Normal/1=Alarm) | Send | 1 Bit | 1.5 alarm | CRT |
| 39 | Heat alarm (0=Normal/1=Alarm) | Send | 1 Bit | 1.5 alarm | CRT |
| 40 | X1: Temperature [°C] | Send | 2 Bytes | 9.1 temperature (°C) | CRT |
| 41 | X1: Digital [0/1] | Send | 1 Bit | 1.1 switch | CRT |
| 42 | X2: Temperature [°C] | Send | 2 Bytes | 9.1 temperature (°C) | CRT |
| 43 | X2: Digital [0/1] | Send | 1 Bit | 1.1 switch | CRT |
| 44 | U1: Temperature [°C] | Send | 2 Bytes | 9.1 temperature (°C) | CRT |
| 45 | U1: Digital [0/1] | Send | 1 Bit | 1.1 switch | CRT |
| 46 | Heating/Cooling changeover (1=Heating/0=Cooling) | Receive | 1 Bit | 1.100 cooling/heating | CWU |
| 47 | Heating/Cooling mode state (1=Heating/0=Cooling) | Send | 1 Bit | 1.100 cooling/heating | CRT |
| 48 | Application mode | Receive | 1 Byte | 20.105 HVAC control mode | CWU |
| 49 | Dew point alarm (0=Normal/1=Alarm) | Receive | 1 Bit | 1.5 alarm | CWU |
| 50 | Enable fan command (0=Disable/1=Enable) | Receive | 1 Bit | 1.3 enable | CWU |
| 51 | Fan operation (0=Auto/1=Manual) | Send | 1 Bit | 1.1 switch | CRT |
| 52 | Fan speed | Receive | 1 Byte | 5.1 percentage (0..100%) | CWU |
| 53 | Fan output | Send | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 54 | Fan speed 1 (0=Off/1=On) | Receive | 1 Bit | 1.1 switch | CWU |
| 55 | Fan speed 2 (0=Off/1=On) | Receive | 1 Bit | 1.1 switch | CWU |
| 56 | Fan speed 3 (0=Off/1=On) | Receive | 1 Bit | 1.1 switch | CWU |
| 57 | Fan speed 1 (0=Off/1=On) | Send | 1 Bit | 1.1 switch | CRT |
| 58 | Fan speed 2 (0=Off/1=On) | Send | 1 Bit | 1.1 switch | CRT |
| 59 | Fan speed 3 (0=Off/1=On) | Send | 1 Bit | 1.1 switch | CRT |
| 60 | Outside temperature | Receive | 2 Bytes | 9.1 temperature (°C) | CWU |
| 61 | Heating, control value continuous | Send | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 62 | Heating, control value continuous, seq 2 | Send | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 63 | Cooling, control value continuous | Send | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 64 | Cooling, control value continuous, seq 2 | Send | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 65 | Heating, control value state (0=Off/1=On) | Send | 1 Bit | 1.11 state | CRT |
| 66 | Heating, control value state seq 2 (0=Off/1=On) | Send | 1 Bit | 1.11 state | CRT |
| 67 | Cooling, control value state (0=Off/1=On) | Send | 1 Bit | 1.11 state | CRT |
| 68 | Cooling, control value state seq 2 (0=Off/1=On) | Send | 1 Bit | 1.11 state | CRT |
| 69 | Heating and cooling, control value state (0=Off/1=On) | Send | 1 Bit | 1.11 state | CRT |
| 70 | Heating and cooling, control value state seq2 (0=Off/1=On) | Send | 1 Bit | 1.11 state | CRT |
| 71 | Heating and cooling, control value continuous | Send | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 72 | Heating and cooling, control value continuous seq 2 | Send | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 73 | Control dehumidification (1=On/0=Off) | Send | 1 Bit | 1.11 state | CRT |
| 74 | Control humidification (1=On/0=Off) | Send | 1 Bit | 1.11 state | CRT |
| 75 | Hum. Control mode (inactive/hum/dehum) | Send | 1 Byte | 20.115 hum dehum mode | CRT |
| 76 | Enable electric heater (0=Disable/1=Enable) | Receive | 1 Bit | 1.3 enable | CWU |
| 77 | Built-in room relative humidity value [%r.H.] | Send | 2 Bytes | 9.7 humidity (%) | CRT |
| 78 | External room relative humidity value [%r.H.] | Receive | 2 Bytes | 9.7 humidity (%) | CWU |
| 79 | Room rel. humidity: Setpoint high | Receive | 2 Bytes | 9.7 humidity (%) | CWU |
| 80 | Room rel. humidity: Setpoint low | Receive | 2 Bytes | 9.7 humidity (%) | CWU |
| 81 | Reset energy efficiency state (Green leaf) | Receive | 1 Bit | 1.17 trigger | CWU |
| 82 | Energy efficiency state / Green Leaf (0=Green/1=Red) | Send | 1 Bit | 1.6 binary value | CRT |
| 83 | Enable/disable Leaf indication (0=Disable/1=Enable) | Receive | 1 Bit | 1.3 enable | CWU |
| 84 | Keypad: Lock fan speed | Receive | 1 Bit | 1.2 boolean | CWU |
| 85 | Keypad: Lock fan speed in “auto” mode | Receive | 1 Bit | 1.2 boolean | CWU |
| 86 | Keypad: Lock the setpoint shift | Receive | 1 Bit | 1.2 boolean | CWU |
| 87 | Keypad: Lock the operating mode | Receive | 1 Bit | 1.2 boolean | CWU |
| 88 | Room operating mode: Presence detector (0=Unoccupied/1=Occupied) | Send | 1 Bit | 1.18 occupancy | CRT |
| 89 | Room operating mode: Window contact (0=Close/1=Open) | Send | 1 Bit | 1.19 window/door | CRT |
| 90 | Room temp: Current Cooling setpoint | Send | 2 Bytes | 9.1 temperature (°C) | CRT |
| 91 | Room temp: Current heating setpoint | Send | 2 Bytes | 9.1 temperature (°C) | CRT |
| 92 | Room temp: Current heating setpoint | Receive | 2 Bytes | 9.1 temperature (°C) | CWU |
| 93 | Room temp: Current cooling setpoint | Receive | 2 Bytes | 9.1 temperature (°C) | CWU |
| 94 | Room operating mode: State | Receive | 1 Byte | 20.102 HVAC mode | CWU |
| 95 | Changeover water state (1=Heating/0=Cooling) | Send | 1 Bit | 1.100 cooling/heating | CRT |
| 96 | Changeover water state (1=Heating/0=Cooling) | Receive | 1 Bit | 1.100 cooling/heating | CWU |
| 97 | Manual fan command | Send | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 98 | DC fan speed: [P359] Maximum speed heating | Receive | 1 Byte | 5.1 percentage (0..100%) | CWU |
| 99 | DC fan speed: [P360] Maximum speed cooling | Receive | 1 Byte | 5.1 percentage (0..100%) | CWU |
Parameters (130)
| Parameter | Type | Default |
|---|---|---|
| Preselection reception: Com. Obj | list | ------- |
| Scheduler reception: Com. Obj | list | ------- |
| State transmission: Com. Obj | list | ------- |
| Room temperature: Economy setpoint | list | As parameters only |
| Window state input | list | Local |
| Presence detector input | list | Local |
| Room temperature: Comfort basic setpoint | list | Disabled |
| [DIP] Plant type | list | ------- |
| [P450] Control strategy | list | Temperature (T) |
| [P003] Operation via fan operating selector | list | Auto - Manual |
| [P004] Unit | list | Degrees Celsius |
| [P005] Scheduler | list | Disabled |
| [P008] Standard display | list | Room temperature |
| [P009] Additional display information | list | ------- |
| [P017] Summer time | list | Europe |
| [P028] Keypad | list | Unlocked |
| [P030] Buzzer function | list | Enabled |
| [P031] Language | list | English |
| [P032] Room operating mode holidays | list | Economy |
| [P258] Manager/Subordinate | list | Manager |
| [P259] Subordinate identification | list | 1 |
| [P500] NFC | list | Enabled |
| [P502] Password | list | Disabled |
| [P503] Password | unsignedInt 0…999 | 0 |
| Presence detector function | list | Standard |
| State object for extended comfort mode | list | Yes |
| [P102] Temporary comfort mode [min] | list | ------- |
| [P010] Setpoint concept | list | Comfort concept |
| [P011] Comfort basic setpoint [°C] | list | 21.0°C |
| [P104] Setpoint display | list | Absolute |
| [P019] Economy heating setpoint [°C] | list | 15.0°C |
| [P020] Economy cooling setpoint [°C] | list | 30.0°C |
| [P100] Protection heating setpoint [°C] | list | 8.0°C |
| [P101] Protection cooling setpoint [°C] | list | ------- |
| [P013] Comfort setpoint minimum [°C] | list | 5.0°C |
| [P016] Comfort setpoint maximum [°C] | list | 35.0°C |
| [P014] Comfort setpoint maximum heating [°C] | list | 21.0°C |
| [P015] Comfort setpoint minimum cooling [°C] | list | 25.0°C |
| [P103] Temporary Comfort setpoint | list | Disabled |
| Room temperature: Current setpoint | list | Disabled |
| Room temperature: Setpoint sets, receive | list | Disabled |
| Room temperature: Setpoint sets, send | list | Disabled |
| Room temperature: Comfort setpoint | list | Disabled |
| Room relative humidity | list | Send |
| Humidity setpoints | list | As parameters only |
| [P451] Humidity control strategy | list | With setpoint shift + external equipment (humid / dehum) |
| [P024] Humidity setpoint high [%] | list | 50% |
| [P026] Humidity setpoint low [%] | list | ------- |
| [P461] Temp setpoint shift (humidity) [K] | list | 3.0 K |
| Application mode input | list | Disabled |
| [P027] Electric heater when cooling | list | Enabled |
| [P200] Number of heating / cooling sequences | list | 2 sequence heating, 2 sequence cooling |
| [P050] Heating P-band Xp [K] | list | 2.0 K |
| [P051] Switching differential heating [K] | list | 1.0 K |
| [P052] Cooling P-band Xp [K] | list | 1.0 K |
| [P053] Switching differential cooling [K] | list | 1.0 K |
| [P054] Radiator P-band Xp/switching differential [K] | list | 2.0 K |
| [P055] Dead zone Comfort mode [K] | list | 2.0 K |
| [P056] Setpoint differential [K] | list | 2.0 K |
| [P057] Integral action time Tn heating [minutes] | unsignedInt 0…120 | 45 |
| [P058] Integral action time Tn cooling [minutes] | unsignedInt 0…120 | 45 |
| [P059] H/C changeover switching point cooling [°C] | list | 16.0°C |
| [P060] H/C changeover switching point heating [°C] | list | 28.0°C |
| [P061] Return temp limit delta cool | list | ------- |
| [P062] Return temp limit delta heat | list | ------- |
| [P063] Minimum supply air temperature [°C] | list | ------- |
| [P064] Maximum supply air temperature [°C] | list | ------- |
| [P110] Energy indicator | list | Green and red dimmed out |
| [P111] Energy indicator range [K] | list | 2.0 K |
| [P217] Power of electric heater on Q2 [kW] | list | 0.0 kW |
| [P250] Valve kick | list | Disabled |
| [P251] Purge time (every 2 hours) [minutes] | list | ------- |
| [P252] Flow temp limit floor heating [°C] | list | 28.0°C |
| [P254] Swap sequence H and C (2-pipe/2-stage) | list | Disabled |
| [P255] Track cooling setpoint on outside temperature | list | Disabled |
| [P256] Flow limitation in heating mode for PICV (Y10 only) | list | 10.0V |
| Frost alarm | list | Disabled |
| Threshold for frost alarm [°C] | list | 5.0°C |
| Overheating alarm | list | Disabled |
| Threshold value overheating [°C] | list | 40.0°C |
| Dewpoint alarm | list | Disabled |
| [P006] Measured value correction [K] | list | 0.0 K |
| [P007] Humidity value correction [%] | list | 0% |
| [P150] Input X1 | list | Room / Return temperature |
| [P153] Input X2 | list | ------- |
| [P155] Input U1 | list | Window contact (DI) |
| [P203] Output Y20 (DC) or Q2 (2-pos.) | list | DC 0...10 V |
| [P204] Output Y30 (DC) | list | DC 0...10 V |
| [P205] Output U1 | list | DC 0...10 V |
| [P212] On time minimum 2-pos output [minutes] | unsignedInt 1…20 | 1 |
| [P213] Off time minimum 2-pos output [minutes] | unsignedInt 1…20 | 1 |
| [P400] Output Q1 function | list | ------- |
| [P401] Output Q2 function | list | ------- |
| [P402] Output Q3 function | list | ------- |
| Fan Output Enable | list | Disabled |
| [P351] Fan speeds | list | DC 0...10 V (ECM fan) |
| [P029] Fan: Dead zone Comfort mode | list | Off |
| [P352] Fan overrun time [seconds] | unsignedInt 0…360 | 60 |
| [P353] Fan speed switching point low (value in %) | unsignedInt 1…100 | 10 |
| [P354] Fan speed switching point med (value in %) | unsignedInt 1…100 | 65 |
| [P355] Fan speed switching point high (value in %) | unsignedInt 1…100 | 100 |
| [P356] DC fan switching point [%] | unsignedInt 1…100 | 10 |
| [P357] DC fan speed low min. output [%] | unsignedInt 1…100 | 30 |
| [P358] DC fan speed med. output [%] | unsignedInt 1…100 | 60 |
| [P359] DC fan speed high max. out. heat [%] | unsignedInt 1…100 | 80 |
| [P360] DC fan speed high max. out. cool [%] | unsignedInt 1…100 | 80 |
| [P361] Fan start kick | list | Enabled |
| [P362] On time minimum fan [minutes] | unsignedInt 1…6 | 2 |
| [P363] Periodic fan kick Comfort [minutes] | list | ------- |
| [P364] Periodic fan kick Economy [minutes] | list | ------- |
| [P365] Fan start delay [seconds] | unsignedInt 0…360 | 0 |
| [P366] Fan start, minimum hot water temperature [°C] | list | 30.0°C |
| [P501] Service filter [hour] | list | ------- |
| [P901] Geographical zone (apartment) | list | ------- |
| [P902] Geographical zone (room) | list | 1 |
| [P001] Control sequence | list | Cooling only |
| [P001] Control sequence | list | Heating and cooling |
| [P151] Normal position X1 | list | Open |
| [P151] Sensor input X1 | list | NTC 3K |
| [P151] Normal position or sensor input X1 | list | Open |
| [P154] Normal position X2 | list | Open |
| [P154] Sensor input X2 | list | NTC 3K |
| [P156] Normal position U1 | list | Open |
| [P156] Sensor input U1 | list | NTC 3K |
| [P156] Normal position or sensor input U1 | list | Open |
| [P350] Fan control | list | Enabled |
| [P201] Output Y10 (DC) or Q1 (2-pos.) | list | DC 0...10 V |
| [P201] Output Y10 (DC) or Q1 (2-pos.) | list | 6-port valve (DC 0…10 V) |
| [P154] Normal position or sensor input X2 | list | Open |
| [P002] Operation via room operating mode selector | list | Auto - Protection |
Version history
| Application | App no | Fingerprint | First seen | Size | File |
|---|---|---|---|---|---|
| RDG260KN 3.3 latest | $1102 | 2F97 | 2026-11-25 | 217 KB | Download |
| RDG260KN 3.2 | $1102 | 0475 | 2026-11-25 | 217 KB | Download |
| RDG260KN 2.0 | $1102 | C65C | 2026-11-25 | 215 KB | Download |
About this file
This is the official ETS product database for the Siemens HVAC RDG260KN Room Thermostat (RDG260KN), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.
More from Siemens HVAC
- AQR2570N Flush Mount Sensor AQR2570N
- AQR2576N Flush Mount Sensor AQR2576N
- GDB111.1E/KN Damper actuator GDB111.1E/KN
- GDB111.9E/KN Rotary actuator GDB111.9E/KN
- GDB181.1E/KN VAV Compact Controller GDB181.1E/KN
- GLB111.1E/KN Damper actuator GLB111.1E/KN
- GLB111.9E/KN Rotary actuator GLB111.9E/KN
- GLB181.1E/KN VAV Compact Controller GLB181.1E/KN
- QAW740 Room Unit QAW740
- QMX3.P02 Room Unit QMX3.P02
- QMX3.P30 Room Unit QMX3.P30
- QMX3.P34 Room Unit QMX3.P34