Siemens HVAC OZW772.16 OZW772.16 Web Server

OZW772.16 Web Server OZW772.16

Siemens HVAC · Order number OZW772.16 · Web Server › Synco

Web browser interface for operation with PC/laptop or smartphone

Download .knxprod OZW772 Web-Server 2.0 · 254 KB

Product

ManufacturerSiemens HVAC
Product nameOZW772.16 Web Server
Order numberOZW772.16
HardwareWeb Server OZW772
MediumTwisted Pair
Bus current (mA)5
Rail mountedNo
RegistrationCertified · 2014-08-26
Languagesde-DE, en-US, fr-FR
Catalog entryM-00FD_H-OZW772-1_HP-C004-20-7887_CI-OZW772.2E16-1
Fingerprint7887
SHA-256923ab05a7c0eeb649eac47abaaecbdc470848c86558511f2f49325fd6bf811d9
First seen2026-11-25
Markets68 markets

Application program: OZW772 Web-Server 2.0

Application number$C004
Version2.0
Mask versionMV-0300 (System 300)
KNX Data SecureNo
Minimum ETS version4.0
Parameters2674
Group objects2262
Group objects (2262)
NoNameFunctionSizeDPTFlags
1System timeReceive / Transmit8 Bytes19.1 date timeCRWTU
2DateReceive / Transmit3 Bytes11.1 dateCRWTU
3Time of dayReceive / Transmit3 Bytes10.1 time of dayCRWTU
4Fault informationTransmit6 Bytes219.1 alarm infoCRT
5Confirm faultsReceive1 Bit1.16 acknowledgeCWU
6Fault state (normal/faulty)Transmit1 Bit1.5 alarmCRT
7Fault transmission (enable/disable)Receive1 Bit1.3 enableCWU
81 Bit Value Change/Display 1Transmit1 Bit1.1 switchCT
81 Bit Value Change/Display 1Transmit1 Bit1.3 enableCT
81 Bit Value Change/Display 1Transmit1 Bit1.8 up/downCT
81 Bit Value Change/Display 1Transmit1 Bit1.9 open/closeCT
81 Bit Value Change/Display 1Transmit1 Bit1.18 occupancyCT
91 Bit Value Change/Display 2Receive1 Bit1.1 switchCWTU
91 Bit Value Change/Display 2Receive1 Bit1.3 enableCWTU
91 Bit Value Change/Display 2Receive1 Bit1.8 up/downCWTU
91 Bit Value Change/Display 2Receive1 Bit1.9 open/closeCWTU
91 Bit Value Change/Display 2Receive1 Bit1.18 occupancyCWTU
101 Bit Value Change/Display 3Transmit1 Bit1.1 switchCT
101 Bit Value Change/Display 3Transmit1 Bit1.3 enableCT
101 Bit Value Change/Display 3Transmit1 Bit1.8 up/downCT
101 Bit Value Change/Display 3Transmit1 Bit1.9 open/closeCT
101 Bit Value Change/Display 3Transmit1 Bit1.18 occupancyCT
111 Bit Value Change/Display 4Receive1 Bit1.1 switchCWTU
111 Bit Value Change/Display 4Receive1 Bit1.3 enableCWTU
111 Bit Value Change/Display 4Receive1 Bit1.8 up/downCWTU
111 Bit Value Change/Display 4Receive1 Bit1.9 open/closeCWTU
111 Bit Value Change/Display 4Receive1 Bit1.18 occupancyCWTU
121 Bit Value Change/Display 5Transmit1 Bit1.1 switchCT
121 Bit Value Change/Display 5Transmit1 Bit1.3 enableCT
121 Bit Value Change/Display 5Transmit1 Bit1.8 up/downCT
121 Bit Value Change/Display 5Transmit1 Bit1.9 open/closeCT
121 Bit Value Change/Display 5Transmit1 Bit1.18 occupancyCT
131 Bit Value Change/Display 6Receive1 Bit1.1 switchCWTU
131 Bit Value Change/Display 6Receive1 Bit1.3 enableCWTU
131 Bit Value Change/Display 6Receive1 Bit1.8 up/downCWTU
131 Bit Value Change/Display 6Receive1 Bit1.9 open/closeCWTU
131 Bit Value Change/Display 6Receive1 Bit1.18 occupancyCWTU
141 Bit Value Change/Display 7Transmit1 Bit1.1 switchCT
141 Bit Value Change/Display 7Transmit1 Bit1.3 enableCT
141 Bit Value Change/Display 7Transmit1 Bit1.8 up/downCT
141 Bit Value Change/Display 7Transmit1 Bit1.9 open/closeCT
141 Bit Value Change/Display 7Transmit1 Bit1.18 occupancyCT
151 Bit Value Change/Display 8Receive1 Bit1.1 switchCWTU
151 Bit Value Change/Display 8Receive1 Bit1.3 enableCWTU
151 Bit Value Change/Display 8Receive1 Bit1.8 up/downCWTU
151 Bit Value Change/Display 8Receive1 Bit1.9 open/closeCWTU
151 Bit Value Change/Display 8Receive1 Bit1.18 occupancyCWTU
161 Bit Value Change/Display 9Transmit1 Bit1.1 switchCT
161 Bit Value Change/Display 9Transmit1 Bit1.3 enableCT
161 Bit Value Change/Display 9Transmit1 Bit1.8 up/downCT
161 Bit Value Change/Display 9Transmit1 Bit1.9 open/closeCT
161 Bit Value Change/Display 9Transmit1 Bit1.18 occupancyCT
171 Bit Value Change/Display 10Receive1 Bit1.1 switchCWTU
171 Bit Value Change/Display 10Receive1 Bit1.3 enableCWTU
171 Bit Value Change/Display 10Receive1 Bit1.8 up/downCWTU
171 Bit Value Change/Display 10Receive1 Bit1.9 open/closeCWTU
171 Bit Value Change/Display 10Receive1 Bit1.18 occupancyCWTU
181 Bit Value Change/Display 11Transmit1 Bit1.1 switchCT
181 Bit Value Change/Display 11Transmit1 Bit1.3 enableCT
181 Bit Value Change/Display 11Transmit1 Bit1.8 up/downCT
181 Bit Value Change/Display 11Transmit1 Bit1.9 open/closeCT
181 Bit Value Change/Display 11Transmit1 Bit1.18 occupancyCT
191 Bit Value Change/Display 12Receive1 Bit1.1 switchCWTU
191 Bit Value Change/Display 12Receive1 Bit1.3 enableCWTU
191 Bit Value Change/Display 12Receive1 Bit1.8 up/downCWTU
191 Bit Value Change/Display 12Receive1 Bit1.9 open/closeCWTU
191 Bit Value Change/Display 12Receive1 Bit1.18 occupancyCWTU
201 Bit Value Change/Display 13Transmit1 Bit1.1 switchCT
201 Bit Value Change/Display 13Transmit1 Bit1.3 enableCT
201 Bit Value Change/Display 13Transmit1 Bit1.8 up/downCT
201 Bit Value Change/Display 13Transmit1 Bit1.9 open/closeCT
201 Bit Value Change/Display 13Transmit1 Bit1.18 occupancyCT
211 Bit Value Change/Display 14Receive1 Bit1.1 switchCWTU
211 Bit Value Change/Display 14Receive1 Bit1.3 enableCWTU
211 Bit Value Change/Display 14Receive1 Bit1.8 up/downCWTU
211 Bit Value Change/Display 14Receive1 Bit1.9 open/closeCWTU
211 Bit Value Change/Display 14Receive1 Bit1.18 occupancyCWTU
221 Bit Value Change/Display 15Transmit1 Bit1.1 switchCT
221 Bit Value Change/Display 15Transmit1 Bit1.3 enableCT
221 Bit Value Change/Display 15Transmit1 Bit1.8 up/downCT
221 Bit Value Change/Display 15Transmit1 Bit1.9 open/closeCT
221 Bit Value Change/Display 15Transmit1 Bit1.18 occupancyCT
231 Bit Value Change/Display 16Receive1 Bit1.1 switchCWTU
231 Bit Value Change/Display 16Receive1 Bit1.3 enableCWTU
231 Bit Value Change/Display 16Receive1 Bit1.8 up/downCWTU
231 Bit Value Change/Display 16Receive1 Bit1.9 open/closeCWTU
231 Bit Value Change/Display 16Receive1 Bit1.18 occupancyCWTU
241 Bit Value Change/Display 17Transmit1 Bit1.1 switchCT
241 Bit Value Change/Display 17Transmit1 Bit1.3 enableCT
241 Bit Value Change/Display 17Transmit1 Bit1.8 up/downCT
241 Bit Value Change/Display 17Transmit1 Bit1.9 open/closeCT
241 Bit Value Change/Display 17Transmit1 Bit1.18 occupancyCT
251 Bit Value Change/Display 18Receive1 Bit1.1 switchCWTU
251 Bit Value Change/Display 18Receive1 Bit1.3 enableCWTU
251 Bit Value Change/Display 18Receive1 Bit1.8 up/downCWTU
251 Bit Value Change/Display 18Receive1 Bit1.9 open/closeCWTU
251 Bit Value Change/Display 18Receive1 Bit1.18 occupancyCWTU
261 Bit Value Change/Display 19Transmit1 Bit1.1 switchCT
261 Bit Value Change/Display 19Transmit1 Bit1.3 enableCT
261 Bit Value Change/Display 19Transmit1 Bit1.8 up/downCT
261 Bit Value Change/Display 19Transmit1 Bit1.9 open/closeCT
261 Bit Value Change/Display 19Transmit1 Bit1.18 occupancyCT
271 Bit Value Change/Display 20Receive1 Bit1.1 switchCWTU
271 Bit Value Change/Display 20Receive1 Bit1.3 enableCWTU
271 Bit Value Change/Display 20Receive1 Bit1.8 up/downCWTU
271 Bit Value Change/Display 20Receive1 Bit1.9 open/closeCWTU
271 Bit Value Change/Display 20Receive1 Bit1.18 occupancyCWTU
281 Bit Value Change/Display 21Transmit1 Bit1.1 switchCT
281 Bit Value Change/Display 21Transmit1 Bit1.3 enableCT
281 Bit Value Change/Display 21Transmit1 Bit1.8 up/downCT
281 Bit Value Change/Display 21Transmit1 Bit1.9 open/closeCT
281 Bit Value Change/Display 21Transmit1 Bit1.18 occupancyCT
291 Bit Value Change/Display 22Receive1 Bit1.1 switchCWTU
291 Bit Value Change/Display 22Receive1 Bit1.3 enableCWTU
291 Bit Value Change/Display 22Receive1 Bit1.8 up/downCWTU
291 Bit Value Change/Display 22Receive1 Bit1.9 open/closeCWTU
291 Bit Value Change/Display 22Receive1 Bit1.18 occupancyCWTU
301 Bit Value Change/Display 23Transmit1 Bit1.1 switchCT
301 Bit Value Change/Display 23Transmit1 Bit1.3 enableCT
301 Bit Value Change/Display 23Transmit1 Bit1.8 up/downCT
301 Bit Value Change/Display 23Transmit1 Bit1.9 open/closeCT
301 Bit Value Change/Display 23Transmit1 Bit1.18 occupancyCT
311 Bit Value Change/Display 24Receive1 Bit1.1 switchCWTU
311 Bit Value Change/Display 24Receive1 Bit1.3 enableCWTU
311 Bit Value Change/Display 24Receive1 Bit1.8 up/downCWTU
311 Bit Value Change/Display 24Receive1 Bit1.9 open/closeCWTU
311 Bit Value Change/Display 24Receive1 Bit1.18 occupancyCWTU
321 Bit Value Change/Display 25Transmit1 Bit1.1 switchCT
321 Bit Value Change/Display 25Transmit1 Bit1.3 enableCT
321 Bit Value Change/Display 25Transmit1 Bit1.8 up/downCT
321 Bit Value Change/Display 25Transmit1 Bit1.9 open/closeCT
321 Bit Value Change/Display 25Transmit1 Bit1.18 occupancyCT
331 Bit Value Change/Display 26Receive1 Bit1.1 switchCWTU
331 Bit Value Change/Display 26Receive1 Bit1.3 enableCWTU
331 Bit Value Change/Display 26Receive1 Bit1.8 up/downCWTU
331 Bit Value Change/Display 26Receive1 Bit1.9 open/closeCWTU
331 Bit Value Change/Display 26Receive1 Bit1.18 occupancyCWTU
341 Bit Value Change/Display 27Transmit1 Bit1.1 switchCT
341 Bit Value Change/Display 27Transmit1 Bit1.3 enableCT
341 Bit Value Change/Display 27Transmit1 Bit1.8 up/downCT
341 Bit Value Change/Display 27Transmit1 Bit1.9 open/closeCT
341 Bit Value Change/Display 27Transmit1 Bit1.18 occupancyCT
351 Bit Value Change/Display 28Receive1 Bit1.1 switchCWTU
351 Bit Value Change/Display 28Receive1 Bit1.3 enableCWTU
351 Bit Value Change/Display 28Receive1 Bit1.8 up/downCWTU
351 Bit Value Change/Display 28Receive1 Bit1.9 open/closeCWTU
351 Bit Value Change/Display 28Receive1 Bit1.18 occupancyCWTU
361 Bit Value Change/Display 29Transmit1 Bit1.1 switchCT
361 Bit Value Change/Display 29Transmit1 Bit1.3 enableCT
361 Bit Value Change/Display 29Transmit1 Bit1.8 up/downCT
361 Bit Value Change/Display 29Transmit1 Bit1.9 open/closeCT
361 Bit Value Change/Display 29Transmit1 Bit1.18 occupancyCT
371 Bit Value Change/Display 30Receive1 Bit1.1 switchCWTU
371 Bit Value Change/Display 30Receive1 Bit1.3 enableCWTU
371 Bit Value Change/Display 30Receive1 Bit1.8 up/downCWTU
371 Bit Value Change/Display 30Receive1 Bit1.9 open/closeCWTU
371 Bit Value Change/Display 30Receive1 Bit1.18 occupancyCWTU
381 Bit Value Change/Display 31Transmit1 Bit1.1 switchCT
381 Bit Value Change/Display 31Transmit1 Bit1.3 enableCT
381 Bit Value Change/Display 31Transmit1 Bit1.8 up/downCT
381 Bit Value Change/Display 31Transmit1 Bit1.9 open/closeCT
381 Bit Value Change/Display 31Transmit1 Bit1.18 occupancyCT
391 Bit Value Change/Display 32Receive1 Bit1.1 switchCWTU
391 Bit Value Change/Display 32Receive1 Bit1.3 enableCWTU
391 Bit Value Change/Display 32Receive1 Bit1.8 up/downCWTU
391 Bit Value Change/Display 32Receive1 Bit1.9 open/closeCWTU
391 Bit Value Change/Display 32Receive1 Bit1.18 occupancyCWTU
401 Bit Value Change/Display 33Transmit1 Bit1.1 switchCT
401 Bit Value Change/Display 33Transmit1 Bit1.3 enableCT
401 Bit Value Change/Display 33Transmit1 Bit1.8 up/downCT
401 Bit Value Change/Display 33Transmit1 Bit1.9 open/closeCT
401 Bit Value Change/Display 33Transmit1 Bit1.18 occupancyCT
411 Bit Value Change/Display 34Receive1 Bit1.1 switchCWTU
411 Bit Value Change/Display 34Receive1 Bit1.3 enableCWTU
411 Bit Value Change/Display 34Receive1 Bit1.8 up/downCWTU
411 Bit Value Change/Display 34Receive1 Bit1.9 open/closeCWTU
411 Bit Value Change/Display 34Receive1 Bit1.18 occupancyCWTU
421 Bit Value Change/Display 35Transmit1 Bit1.1 switchCT
421 Bit Value Change/Display 35Transmit1 Bit1.3 enableCT
421 Bit Value Change/Display 35Transmit1 Bit1.8 up/downCT
421 Bit Value Change/Display 35Transmit1 Bit1.9 open/closeCT
421 Bit Value Change/Display 35Transmit1 Bit1.18 occupancyCT
431 Bit Value Change/Display 36Receive1 Bit1.1 switchCWTU
431 Bit Value Change/Display 36Receive1 Bit1.3 enableCWTU
431 Bit Value Change/Display 36Receive1 Bit1.8 up/downCWTU
431 Bit Value Change/Display 36Receive1 Bit1.9 open/closeCWTU
431 Bit Value Change/Display 36Receive1 Bit1.18 occupancyCWTU
441 Bit Value Change/Display 37Transmit1 Bit1.1 switchCT
441 Bit Value Change/Display 37Transmit1 Bit1.3 enableCT
441 Bit Value Change/Display 37Transmit1 Bit1.8 up/downCT
441 Bit Value Change/Display 37Transmit1 Bit1.9 open/closeCT
441 Bit Value Change/Display 37Transmit1 Bit1.18 occupancyCT
451 Bit Value Change/Display 38Receive1 Bit1.1 switchCWTU
451 Bit Value Change/Display 38Receive1 Bit1.3 enableCWTU
451 Bit Value Change/Display 38Receive1 Bit1.8 up/downCWTU
451 Bit Value Change/Display 38Receive1 Bit1.9 open/closeCWTU
451 Bit Value Change/Display 38Receive1 Bit1.18 occupancyCWTU
461 Bit Value Change/Display 39Transmit1 Bit1.1 switchCT
461 Bit Value Change/Display 39Transmit1 Bit1.3 enableCT
461 Bit Value Change/Display 39Transmit1 Bit1.8 up/downCT
461 Bit Value Change/Display 39Transmit1 Bit1.9 open/closeCT
461 Bit Value Change/Display 39Transmit1 Bit1.18 occupancyCT
471 Bit Value Change/Display 40Receive1 Bit1.1 switchCWTU
471 Bit Value Change/Display 40Receive1 Bit1.3 enableCWTU
471 Bit Value Change/Display 40Receive1 Bit1.8 up/downCWTU
471 Bit Value Change/Display 40Receive1 Bit1.9 open/closeCWTU
471 Bit Value Change/Display 40Receive1 Bit1.18 occupancyCWTU
481 Bit Value Change 1Transmit1 Bit1.1 switchCT
481 Bit Value Change 1Transmit1 Bit1.2 booleanCT
481 Bit Value Change 1Transmit1 Bit1.3 enableCT
481 Bit Value Change 1Transmit1 Bit1.5 alarmCT
481 Bit Value Change 1Transmit1 Bit1.6 binary valueCT
481 Bit Value Change 1Transmit1 Bit1.7 stepCT
481 Bit Value Change 1Transmit1 Bit1.8 up/downCT
481 Bit Value Change 1Transmit1 Bit1.9 open/closeCT
481 Bit Value Change 1Transmit1 Bit1.10 start/stopCT
481 Bit Value Change 1Transmit1 Bit1.17 triggerCT
481 Bit Value Change 1Transmit1 Bit1.18 occupancyCT
491 Bit Value Change 2Transmit1 Bit1.1 switchCT
491 Bit Value Change 2Transmit1 Bit1.2 booleanCT
491 Bit Value Change 2Transmit1 Bit1.3 enableCT
491 Bit Value Change 2Transmit1 Bit1.5 alarmCT
491 Bit Value Change 2Transmit1 Bit1.6 binary valueCT
491 Bit Value Change 2Transmit1 Bit1.7 stepCT
491 Bit Value Change 2Transmit1 Bit1.8 up/downCT
491 Bit Value Change 2Transmit1 Bit1.9 open/closeCT
491 Bit Value Change 2Transmit1 Bit1.10 start/stopCT
491 Bit Value Change 2Transmit1 Bit1.17 triggerCT
491 Bit Value Change 2Transmit1 Bit1.18 occupancyCT
501 Bit Value Change 3Transmit1 Bit1.1 switchCT
501 Bit Value Change 3Transmit1 Bit1.2 booleanCT
501 Bit Value Change 3Transmit1 Bit1.3 enableCT
501 Bit Value Change 3Transmit1 Bit1.5 alarmCT
501 Bit Value Change 3Transmit1 Bit1.6 binary valueCT
501 Bit Value Change 3Transmit1 Bit1.7 stepCT
501 Bit Value Change 3Transmit1 Bit1.8 up/downCT
501 Bit Value Change 3Transmit1 Bit1.9 open/closeCT
501 Bit Value Change 3Transmit1 Bit1.10 start/stopCT
501 Bit Value Change 3Transmit1 Bit1.17 triggerCT
501 Bit Value Change 3Transmit1 Bit1.18 occupancyCT
511 Bit Value Change 4Transmit1 Bit1.1 switchCT
511 Bit Value Change 4Transmit1 Bit1.2 booleanCT
511 Bit Value Change 4Transmit1 Bit1.3 enableCT
511 Bit Value Change 4Transmit1 Bit1.5 alarmCT
511 Bit Value Change 4Transmit1 Bit1.6 binary valueCT
511 Bit Value Change 4Transmit1 Bit1.7 stepCT
511 Bit Value Change 4Transmit1 Bit1.8 up/downCT
511 Bit Value Change 4Transmit1 Bit1.9 open/closeCT
511 Bit Value Change 4Transmit1 Bit1.10 start/stopCT
511 Bit Value Change 4Transmit1 Bit1.17 triggerCT
511 Bit Value Change 4Transmit1 Bit1.18 occupancyCT
521 Bit Value Change 5Transmit1 Bit1.1 switchCT
521 Bit Value Change 5Transmit1 Bit1.2 booleanCT
521 Bit Value Change 5Transmit1 Bit1.3 enableCT
521 Bit Value Change 5Transmit1 Bit1.5 alarmCT
521 Bit Value Change 5Transmit1 Bit1.6 binary valueCT
521 Bit Value Change 5Transmit1 Bit1.7 stepCT
521 Bit Value Change 5Transmit1 Bit1.8 up/downCT
521 Bit Value Change 5Transmit1 Bit1.9 open/closeCT
521 Bit Value Change 5Transmit1 Bit1.10 start/stopCT
521 Bit Value Change 5Transmit1 Bit1.17 triggerCT
521 Bit Value Change 5Transmit1 Bit1.18 occupancyCT
531 Bit Value Change 6Transmit1 Bit1.1 switchCT
531 Bit Value Change 6Transmit1 Bit1.2 booleanCT
531 Bit Value Change 6Transmit1 Bit1.3 enableCT
531 Bit Value Change 6Transmit1 Bit1.5 alarmCT
531 Bit Value Change 6Transmit1 Bit1.6 binary valueCT
531 Bit Value Change 6Transmit1 Bit1.7 stepCT
531 Bit Value Change 6Transmit1 Bit1.8 up/downCT
531 Bit Value Change 6Transmit1 Bit1.9 open/closeCT
531 Bit Value Change 6Transmit1 Bit1.10 start/stopCT
531 Bit Value Change 6Transmit1 Bit1.17 triggerCT
531 Bit Value Change 6Transmit1 Bit1.18 occupancyCT
541 Bit Value Change 7Transmit1 Bit1.1 switchCT
541 Bit Value Change 7Transmit1 Bit1.2 booleanCT
541 Bit Value Change 7Transmit1 Bit1.3 enableCT
541 Bit Value Change 7Transmit1 Bit1.5 alarmCT
541 Bit Value Change 7Transmit1 Bit1.6 binary valueCT
541 Bit Value Change 7Transmit1 Bit1.7 stepCT
541 Bit Value Change 7Transmit1 Bit1.8 up/downCT
541 Bit Value Change 7Transmit1 Bit1.9 open/closeCT
541 Bit Value Change 7Transmit1 Bit1.10 start/stopCT
541 Bit Value Change 7Transmit1 Bit1.17 triggerCT
541 Bit Value Change 7Transmit1 Bit1.18 occupancyCT
551 Bit Value Change 8Transmit1 Bit1.1 switchCT
551 Bit Value Change 8Transmit1 Bit1.2 booleanCT
551 Bit Value Change 8Transmit1 Bit1.3 enableCT
551 Bit Value Change 8Transmit1 Bit1.5 alarmCT
551 Bit Value Change 8Transmit1 Bit1.6 binary valueCT
551 Bit Value Change 8Transmit1 Bit1.7 stepCT
551 Bit Value Change 8Transmit1 Bit1.8 up/downCT
551 Bit Value Change 8Transmit1 Bit1.9 open/closeCT
551 Bit Value Change 8Transmit1 Bit1.10 start/stopCT
551 Bit Value Change 8Transmit1 Bit1.17 triggerCT
551 Bit Value Change 8Transmit1 Bit1.18 occupancyCT
561 Bit Value Change 9Transmit1 Bit1.1 switchCT
561 Bit Value Change 9Transmit1 Bit1.2 booleanCT
561 Bit Value Change 9Transmit1 Bit1.3 enableCT
561 Bit Value Change 9Transmit1 Bit1.5 alarmCT
561 Bit Value Change 9Transmit1 Bit1.6 binary valueCT
561 Bit Value Change 9Transmit1 Bit1.7 stepCT
561 Bit Value Change 9Transmit1 Bit1.8 up/downCT
561 Bit Value Change 9Transmit1 Bit1.9 open/closeCT
561 Bit Value Change 9Transmit1 Bit1.10 start/stopCT
561 Bit Value Change 9Transmit1 Bit1.17 triggerCT
561 Bit Value Change 9Transmit1 Bit1.18 occupancyCT
571 Bit Value Change 10Transmit1 Bit1.1 switchCT
571 Bit Value Change 10Transmit1 Bit1.2 booleanCT
571 Bit Value Change 10Transmit1 Bit1.3 enableCT
571 Bit Value Change 10Transmit1 Bit1.5 alarmCT
571 Bit Value Change 10Transmit1 Bit1.6 binary valueCT
571 Bit Value Change 10Transmit1 Bit1.7 stepCT
571 Bit Value Change 10Transmit1 Bit1.8 up/downCT
571 Bit Value Change 10Transmit1 Bit1.9 open/closeCT
571 Bit Value Change 10Transmit1 Bit1.10 start/stopCT
571 Bit Value Change 10Transmit1 Bit1.17 triggerCT
571 Bit Value Change 10Transmit1 Bit1.18 occupancyCT
581 Bit Value Change 11Transmit1 Bit1.1 switchCT
581 Bit Value Change 11Transmit1 Bit1.2 booleanCT
581 Bit Value Change 11Transmit1 Bit1.3 enableCT
581 Bit Value Change 11Transmit1 Bit1.5 alarmCT
581 Bit Value Change 11Transmit1 Bit1.6 binary valueCT
581 Bit Value Change 11Transmit1 Bit1.7 stepCT
581 Bit Value Change 11Transmit1 Bit1.8 up/downCT
581 Bit Value Change 11Transmit1 Bit1.9 open/closeCT
581 Bit Value Change 11Transmit1 Bit1.10 start/stopCT
581 Bit Value Change 11Transmit1 Bit1.17 triggerCT
581 Bit Value Change 11Transmit1 Bit1.18 occupancyCT
591 Bit Value Change 12Transmit1 Bit1.1 switchCT
591 Bit Value Change 12Transmit1 Bit1.2 booleanCT
591 Bit Value Change 12Transmit1 Bit1.3 enableCT
591 Bit Value Change 12Transmit1 Bit1.5 alarmCT
591 Bit Value Change 12Transmit1 Bit1.6 binary valueCT
591 Bit Value Change 12Transmit1 Bit1.7 stepCT
591 Bit Value Change 12Transmit1 Bit1.8 up/downCT
591 Bit Value Change 12Transmit1 Bit1.9 open/closeCT
591 Bit Value Change 12Transmit1 Bit1.10 start/stopCT
591 Bit Value Change 12Transmit1 Bit1.17 triggerCT
591 Bit Value Change 12Transmit1 Bit1.18 occupancyCT
601 Bit Value Change 13Transmit1 Bit1.1 switchCT
601 Bit Value Change 13Transmit1 Bit1.2 booleanCT
601 Bit Value Change 13Transmit1 Bit1.3 enableCT
601 Bit Value Change 13Transmit1 Bit1.5 alarmCT
601 Bit Value Change 13Transmit1 Bit1.6 binary valueCT
601 Bit Value Change 13Transmit1 Bit1.7 stepCT
601 Bit Value Change 13Transmit1 Bit1.8 up/downCT
601 Bit Value Change 13Transmit1 Bit1.9 open/closeCT
601 Bit Value Change 13Transmit1 Bit1.10 start/stopCT
601 Bit Value Change 13Transmit1 Bit1.17 triggerCT
601 Bit Value Change 13Transmit1 Bit1.18 occupancyCT
611 Bit Value Change 14Transmit1 Bit1.1 switchCT
611 Bit Value Change 14Transmit1 Bit1.2 booleanCT
611 Bit Value Change 14Transmit1 Bit1.3 enableCT
611 Bit Value Change 14Transmit1 Bit1.5 alarmCT
611 Bit Value Change 14Transmit1 Bit1.6 binary valueCT
611 Bit Value Change 14Transmit1 Bit1.7 stepCT
611 Bit Value Change 14Transmit1 Bit1.8 up/downCT
611 Bit Value Change 14Transmit1 Bit1.9 open/closeCT
611 Bit Value Change 14Transmit1 Bit1.10 start/stopCT
611 Bit Value Change 14Transmit1 Bit1.17 triggerCT
611 Bit Value Change 14Transmit1 Bit1.18 occupancyCT
621 Bit Value Change 15Transmit1 Bit1.1 switchCT
621 Bit Value Change 15Transmit1 Bit1.2 booleanCT
621 Bit Value Change 15Transmit1 Bit1.3 enableCT
621 Bit Value Change 15Transmit1 Bit1.5 alarmCT
621 Bit Value Change 15Transmit1 Bit1.6 binary valueCT
621 Bit Value Change 15Transmit1 Bit1.7 stepCT
621 Bit Value Change 15Transmit1 Bit1.8 up/downCT
621 Bit Value Change 15Transmit1 Bit1.9 open/closeCT
621 Bit Value Change 15Transmit1 Bit1.10 start/stopCT
621 Bit Value Change 15Transmit1 Bit1.17 triggerCT
621 Bit Value Change 15Transmit1 Bit1.18 occupancyCT
631 Bit Value Change 16Transmit1 Bit1.1 switchCT
631 Bit Value Change 16Transmit1 Bit1.2 booleanCT
631 Bit Value Change 16Transmit1 Bit1.3 enableCT
631 Bit Value Change 16Transmit1 Bit1.5 alarmCT
631 Bit Value Change 16Transmit1 Bit1.6 binary valueCT
631 Bit Value Change 16Transmit1 Bit1.7 stepCT
631 Bit Value Change 16Transmit1 Bit1.8 up/downCT
631 Bit Value Change 16Transmit1 Bit1.9 open/closeCT
631 Bit Value Change 16Transmit1 Bit1.10 start/stopCT
631 Bit Value Change 16Transmit1 Bit1.17 triggerCT
631 Bit Value Change 16Transmit1 Bit1.18 occupancyCT
641 Bit Value Change 17Transmit1 Bit1.1 switchCT
641 Bit Value Change 17Transmit1 Bit1.2 booleanCT
641 Bit Value Change 17Transmit1 Bit1.3 enableCT
641 Bit Value Change 17Transmit1 Bit1.5 alarmCT
641 Bit Value Change 17Transmit1 Bit1.6 binary valueCT
641 Bit Value Change 17Transmit1 Bit1.7 stepCT
641 Bit Value Change 17Transmit1 Bit1.8 up/downCT
641 Bit Value Change 17Transmit1 Bit1.9 open/closeCT
641 Bit Value Change 17Transmit1 Bit1.10 start/stopCT
641 Bit Value Change 17Transmit1 Bit1.17 triggerCT
641 Bit Value Change 17Transmit1 Bit1.18 occupancyCT
651 Bit Value Change 18Transmit1 Bit1.1 switchCT
651 Bit Value Change 18Transmit1 Bit1.2 booleanCT
651 Bit Value Change 18Transmit1 Bit1.3 enableCT
651 Bit Value Change 18Transmit1 Bit1.5 alarmCT
651 Bit Value Change 18Transmit1 Bit1.6 binary valueCT
651 Bit Value Change 18Transmit1 Bit1.7 stepCT
651 Bit Value Change 18Transmit1 Bit1.8 up/downCT
651 Bit Value Change 18Transmit1 Bit1.9 open/closeCT
651 Bit Value Change 18Transmit1 Bit1.10 start/stopCT
651 Bit Value Change 18Transmit1 Bit1.17 triggerCT
651 Bit Value Change 18Transmit1 Bit1.18 occupancyCT
661 Bit Value Change 19Transmit1 Bit1.1 switchCT
661 Bit Value Change 19Transmit1 Bit1.2 booleanCT
661 Bit Value Change 19Transmit1 Bit1.3 enableCT
661 Bit Value Change 19Transmit1 Bit1.5 alarmCT
661 Bit Value Change 19Transmit1 Bit1.6 binary valueCT
661 Bit Value Change 19Transmit1 Bit1.7 stepCT
661 Bit Value Change 19Transmit1 Bit1.8 up/downCT
661 Bit Value Change 19Transmit1 Bit1.9 open/closeCT
661 Bit Value Change 19Transmit1 Bit1.10 start/stopCT
661 Bit Value Change 19Transmit1 Bit1.17 triggerCT
661 Bit Value Change 19Transmit1 Bit1.18 occupancyCT
671 Bit Value Change 20Transmit1 Bit1.1 switchCT
671 Bit Value Change 20Transmit1 Bit1.2 booleanCT
671 Bit Value Change 20Transmit1 Bit1.3 enableCT
671 Bit Value Change 20Transmit1 Bit1.5 alarmCT
671 Bit Value Change 20Transmit1 Bit1.6 binary valueCT
671 Bit Value Change 20Transmit1 Bit1.7 stepCT
671 Bit Value Change 20Transmit1 Bit1.8 up/downCT
671 Bit Value Change 20Transmit1 Bit1.9 open/closeCT
671 Bit Value Change 20Transmit1 Bit1.10 start/stopCT
671 Bit Value Change 20Transmit1 Bit1.17 triggerCT
671 Bit Value Change 20Transmit1 Bit1.18 occupancyCT
681 Bit Blind 1Transmit1 Bit1.7 stepCT
681 Bit Blind 1Transmit1 Bit1.8 up/downCT
691 Bit Blind 2Transmit1 Bit1.7 stepCT
691 Bit Blind 2Transmit1 Bit1.8 up/downCT
701 Bit Blind 3Transmit1 Bit1.7 stepCT
701 Bit Blind 3Transmit1 Bit1.8 up/downCT
711 Bit Blind 4Transmit1 Bit1.7 stepCT
711 Bit Blind 4Transmit1 Bit1.8 up/downCT
721 Bit Blind 5Transmit1 Bit1.7 stepCT
721 Bit Blind 5Transmit1 Bit1.8 up/downCT
731 Bit Blind 6Transmit1 Bit1.7 stepCT
731 Bit Blind 6Transmit1 Bit1.8 up/downCT
741 Bit Blind 7Transmit1 Bit1.7 stepCT
741 Bit Blind 7Transmit1 Bit1.8 up/downCT
751 Bit Blind 8Transmit1 Bit1.7 stepCT
751 Bit Blind 8Transmit1 Bit1.8 up/downCT
761 Bit Blind 9Transmit1 Bit1.7 stepCT
761 Bit Blind 9Transmit1 Bit1.8 up/downCT
771 Bit Blind 10Transmit1 Bit1.7 stepCT
771 Bit Blind 10Transmit1 Bit1.8 up/downCT
781 Bit Blind 11Transmit1 Bit1.7 stepCT
781 Bit Blind 11Transmit1 Bit1.8 up/downCT
791 Bit Blind 12Transmit1 Bit1.7 stepCT
791 Bit Blind 12Transmit1 Bit1.8 up/downCT
801 Bit Blind 13Transmit1 Bit1.7 stepCT
801 Bit Blind 13Transmit1 Bit1.8 up/downCT
811 Bit Blind 14Transmit1 Bit1.7 stepCT
811 Bit Blind 14Transmit1 Bit1.8 up/downCT
821 Bit Blind 15Transmit1 Bit1.7 stepCT
821 Bit Blind 15Transmit1 Bit1.8 up/downCT
831 Bit Blind 16Transmit1 Bit1.7 stepCT
831 Bit Blind 16Transmit1 Bit1.8 up/downCT
841 Bit Blind 17Transmit1 Bit1.7 stepCT
841 Bit Blind 17Transmit1 Bit1.8 up/downCT
851 Bit Blind 18Transmit1 Bit1.7 stepCT
851 Bit Blind 18Transmit1 Bit1.8 up/downCT
861 Bit Blind 19Transmit1 Bit1.7 stepCT
861 Bit Blind 19Transmit1 Bit1.8 up/downCT
871 Bit Blind 20Transmit1 Bit1.7 stepCT
871 Bit Blind 20Transmit1 Bit1.8 up/downCT
881 Bit Value Display 1Receive1 Bit1.1 switchCWTU
881 Bit Value Display 1Receive1 Bit1.2 booleanCWTU
881 Bit Value Display 1Receive1 Bit1.3 enableCWTU
881 Bit Value Display 1Receive1 Bit1.5 alarmCWTU
881 Bit Value Display 1Receive1 Bit1.6 binary valueCWTU
881 Bit Value Display 1Receive1 Bit1.9 open/closeCWTU
881 Bit Value Display 1Receive1 Bit1.11 stateCWTU
881 Bit Value Display 1Receive1 Bit1.18 occupancyCWTU
881 Bit Value Display 1Receive1 Bit1.19 window/doorCWTU
891 Bit Value Display 2Receive1 Bit1.1 switchCWTU
891 Bit Value Display 2Receive1 Bit1.2 booleanCWTU
891 Bit Value Display 2Receive1 Bit1.3 enableCWTU
891 Bit Value Display 2Receive1 Bit1.5 alarmCWTU
891 Bit Value Display 2Receive1 Bit1.6 binary valueCWTU
891 Bit Value Display 2Receive1 Bit1.9 open/closeCWTU
891 Bit Value Display 2Receive1 Bit1.11 stateCWTU
891 Bit Value Display 2Receive1 Bit1.18 occupancyCWTU
891 Bit Value Display 2Receive1 Bit1.19 window/doorCWTU
901 Bit Value Display 3Receive1 Bit1.1 switchCWTU
901 Bit Value Display 3Receive1 Bit1.2 booleanCWTU
901 Bit Value Display 3Receive1 Bit1.3 enableCWTU
901 Bit Value Display 3Receive1 Bit1.5 alarmCWTU
901 Bit Value Display 3Receive1 Bit1.6 binary valueCWTU
901 Bit Value Display 3Receive1 Bit1.9 open/closeCWTU
901 Bit Value Display 3Receive1 Bit1.11 stateCWTU
901 Bit Value Display 3Receive1 Bit1.18 occupancyCWTU
901 Bit Value Display 3Receive1 Bit1.19 window/doorCWTU
911 Bit Value Display 4Receive1 Bit1.1 switchCWTU
911 Bit Value Display 4Receive1 Bit1.2 booleanCWTU
911 Bit Value Display 4Receive1 Bit1.3 enableCWTU
911 Bit Value Display 4Receive1 Bit1.5 alarmCWTU
911 Bit Value Display 4Receive1 Bit1.6 binary valueCWTU
911 Bit Value Display 4Receive1 Bit1.9 open/closeCWTU
911 Bit Value Display 4Receive1 Bit1.11 stateCWTU
911 Bit Value Display 4Receive1 Bit1.18 occupancyCWTU
911 Bit Value Display 4Receive1 Bit1.19 window/doorCWTU
921 Bit Value Display 5Receive1 Bit1.1 switchCWTU
921 Bit Value Display 5Receive1 Bit1.2 booleanCWTU
921 Bit Value Display 5Receive1 Bit1.3 enableCWTU
921 Bit Value Display 5Receive1 Bit1.5 alarmCWTU
921 Bit Value Display 5Receive1 Bit1.6 binary valueCWTU
921 Bit Value Display 5Receive1 Bit1.9 open/closeCWTU
921 Bit Value Display 5Receive1 Bit1.11 stateCWTU
921 Bit Value Display 5Receive1 Bit1.18 occupancyCWTU
921 Bit Value Display 5Receive1 Bit1.19 window/doorCWTU
931 Bit Value Display 6Receive1 Bit1.1 switchCWTU
931 Bit Value Display 6Receive1 Bit1.2 booleanCWTU
931 Bit Value Display 6Receive1 Bit1.3 enableCWTU
931 Bit Value Display 6Receive1 Bit1.5 alarmCWTU
931 Bit Value Display 6Receive1 Bit1.6 binary valueCWTU
931 Bit Value Display 6Receive1 Bit1.9 open/closeCWTU
931 Bit Value Display 6Receive1 Bit1.11 stateCWTU
931 Bit Value Display 6Receive1 Bit1.18 occupancyCWTU
931 Bit Value Display 6Receive1 Bit1.19 window/doorCWTU
941 Bit Value Display 7Receive1 Bit1.1 switchCWTU
941 Bit Value Display 7Receive1 Bit1.2 booleanCWTU
941 Bit Value Display 7Receive1 Bit1.3 enableCWTU
941 Bit Value Display 7Receive1 Bit1.5 alarmCWTU
941 Bit Value Display 7Receive1 Bit1.6 binary valueCWTU
941 Bit Value Display 7Receive1 Bit1.9 open/closeCWTU
941 Bit Value Display 7Receive1 Bit1.11 stateCWTU
941 Bit Value Display 7Receive1 Bit1.18 occupancyCWTU
941 Bit Value Display 7Receive1 Bit1.19 window/doorCWTU
951 Bit Value Display 8Receive1 Bit1.1 switchCWTU
951 Bit Value Display 8Receive1 Bit1.2 booleanCWTU
951 Bit Value Display 8Receive1 Bit1.3 enableCWTU
951 Bit Value Display 8Receive1 Bit1.5 alarmCWTU
951 Bit Value Display 8Receive1 Bit1.6 binary valueCWTU
951 Bit Value Display 8Receive1 Bit1.9 open/closeCWTU
951 Bit Value Display 8Receive1 Bit1.11 stateCWTU
951 Bit Value Display 8Receive1 Bit1.18 occupancyCWTU
951 Bit Value Display 8Receive1 Bit1.19 window/doorCWTU
961 Bit Value Display 9Receive1 Bit1.1 switchCWTU
961 Bit Value Display 9Receive1 Bit1.2 booleanCWTU
961 Bit Value Display 9Receive1 Bit1.3 enableCWTU
961 Bit Value Display 9Receive1 Bit1.5 alarmCWTU
961 Bit Value Display 9Receive1 Bit1.6 binary valueCWTU
961 Bit Value Display 9Receive1 Bit1.9 open/closeCWTU
961 Bit Value Display 9Receive1 Bit1.11 stateCWTU
961 Bit Value Display 9Receive1 Bit1.18 occupancyCWTU
961 Bit Value Display 9Receive1 Bit1.19 window/doorCWTU
971 Bit Value Display 10Receive1 Bit1.1 switchCWTU
971 Bit Value Display 10Receive1 Bit1.2 booleanCWTU
971 Bit Value Display 10Receive1 Bit1.3 enableCWTU
971 Bit Value Display 10Receive1 Bit1.5 alarmCWTU
971 Bit Value Display 10Receive1 Bit1.6 binary valueCWTU
971 Bit Value Display 10Receive1 Bit1.9 open/closeCWTU
971 Bit Value Display 10Receive1 Bit1.11 stateCWTU
971 Bit Value Display 10Receive1 Bit1.18 occupancyCWTU
971 Bit Value Display 10Receive1 Bit1.19 window/doorCWTU
981 Bit Value Display 11Receive1 Bit1.1 switchCWTU
981 Bit Value Display 11Receive1 Bit1.2 booleanCWTU
981 Bit Value Display 11Receive1 Bit1.3 enableCWTU
981 Bit Value Display 11Receive1 Bit1.5 alarmCWTU
981 Bit Value Display 11Receive1 Bit1.6 binary valueCWTU
981 Bit Value Display 11Receive1 Bit1.9 open/closeCWTU
981 Bit Value Display 11Receive1 Bit1.11 stateCWTU
981 Bit Value Display 11Receive1 Bit1.18 occupancyCWTU
981 Bit Value Display 11Receive1 Bit1.19 window/doorCWTU
991 Bit Value Display 12Receive1 Bit1.1 switchCWTU
991 Bit Value Display 12Receive1 Bit1.2 booleanCWTU
991 Bit Value Display 12Receive1 Bit1.3 enableCWTU
991 Bit Value Display 12Receive1 Bit1.5 alarmCWTU
991 Bit Value Display 12Receive1 Bit1.6 binary valueCWTU
991 Bit Value Display 12Receive1 Bit1.9 open/closeCWTU
991 Bit Value Display 12Receive1 Bit1.11 stateCWTU
991 Bit Value Display 12Receive1 Bit1.18 occupancyCWTU
991 Bit Value Display 12Receive1 Bit1.19 window/doorCWTU
1001 Bit Value Display 13Receive1 Bit1.1 switchCWTU
1001 Bit Value Display 13Receive1 Bit1.2 booleanCWTU
1001 Bit Value Display 13Receive1 Bit1.3 enableCWTU
1001 Bit Value Display 13Receive1 Bit1.5 alarmCWTU
1001 Bit Value Display 13Receive1 Bit1.6 binary valueCWTU
1001 Bit Value Display 13Receive1 Bit1.9 open/closeCWTU
1001 Bit Value Display 13Receive1 Bit1.11 stateCWTU
1001 Bit Value Display 13Receive1 Bit1.18 occupancyCWTU
1001 Bit Value Display 13Receive1 Bit1.19 window/doorCWTU
1011 Bit Value Display 14Receive1 Bit1.1 switchCWTU
1011 Bit Value Display 14Receive1 Bit1.2 booleanCWTU
1011 Bit Value Display 14Receive1 Bit1.3 enableCWTU
1011 Bit Value Display 14Receive1 Bit1.5 alarmCWTU
1011 Bit Value Display 14Receive1 Bit1.6 binary valueCWTU
1011 Bit Value Display 14Receive1 Bit1.9 open/closeCWTU
1011 Bit Value Display 14Receive1 Bit1.11 stateCWTU
1011 Bit Value Display 14Receive1 Bit1.18 occupancyCWTU
1011 Bit Value Display 14Receive1 Bit1.19 window/doorCWTU
1021 Bit Value Display 15Receive1 Bit1.1 switchCWTU
1021 Bit Value Display 15Receive1 Bit1.2 booleanCWTU
1021 Bit Value Display 15Receive1 Bit1.3 enableCWTU
1021 Bit Value Display 15Receive1 Bit1.5 alarmCWTU
1021 Bit Value Display 15Receive1 Bit1.6 binary valueCWTU
1021 Bit Value Display 15Receive1 Bit1.9 open/closeCWTU
1021 Bit Value Display 15Receive1 Bit1.11 stateCWTU
1021 Bit Value Display 15Receive1 Bit1.18 occupancyCWTU
1021 Bit Value Display 15Receive1 Bit1.19 window/doorCWTU
1031 Bit Value Display 16Receive1 Bit1.1 switchCWTU
1031 Bit Value Display 16Receive1 Bit1.2 booleanCWTU
1031 Bit Value Display 16Receive1 Bit1.3 enableCWTU
1031 Bit Value Display 16Receive1 Bit1.5 alarmCWTU
1031 Bit Value Display 16Receive1 Bit1.6 binary valueCWTU
1031 Bit Value Display 16Receive1 Bit1.9 open/closeCWTU
1031 Bit Value Display 16Receive1 Bit1.11 stateCWTU
1031 Bit Value Display 16Receive1 Bit1.18 occupancyCWTU
1031 Bit Value Display 16Receive1 Bit1.19 window/doorCWTU
1041 Bit Value Display 17Receive1 Bit1.1 switchCWTU
1041 Bit Value Display 17Receive1 Bit1.2 booleanCWTU
1041 Bit Value Display 17Receive1 Bit1.3 enableCWTU
1041 Bit Value Display 17Receive1 Bit1.5 alarmCWTU
1041 Bit Value Display 17Receive1 Bit1.6 binary valueCWTU
1041 Bit Value Display 17Receive1 Bit1.9 open/closeCWTU
1041 Bit Value Display 17Receive1 Bit1.11 stateCWTU
1041 Bit Value Display 17Receive1 Bit1.18 occupancyCWTU
1041 Bit Value Display 17Receive1 Bit1.19 window/doorCWTU
1051 Bit Value Display 18Receive1 Bit1.1 switchCWTU
1051 Bit Value Display 18Receive1 Bit1.2 booleanCWTU
1051 Bit Value Display 18Receive1 Bit1.3 enableCWTU
1051 Bit Value Display 18Receive1 Bit1.5 alarmCWTU
1051 Bit Value Display 18Receive1 Bit1.6 binary valueCWTU
1051 Bit Value Display 18Receive1 Bit1.9 open/closeCWTU
1051 Bit Value Display 18Receive1 Bit1.11 stateCWTU
1051 Bit Value Display 18Receive1 Bit1.18 occupancyCWTU
1051 Bit Value Display 18Receive1 Bit1.19 window/doorCWTU
1061 Bit Value Display 19Receive1 Bit1.1 switchCWTU
1061 Bit Value Display 19Receive1 Bit1.2 booleanCWTU
1061 Bit Value Display 19Receive1 Bit1.3 enableCWTU
1061 Bit Value Display 19Receive1 Bit1.5 alarmCWTU
1061 Bit Value Display 19Receive1 Bit1.6 binary valueCWTU
1061 Bit Value Display 19Receive1 Bit1.9 open/closeCWTU
1061 Bit Value Display 19Receive1 Bit1.11 stateCWTU
1061 Bit Value Display 19Receive1 Bit1.18 occupancyCWTU
1061 Bit Value Display 19Receive1 Bit1.19 window/doorCWTU
1071 Bit Value Display 20Receive1 Bit1.1 switchCWTU
1071 Bit Value Display 20Receive1 Bit1.2 booleanCWTU
1071 Bit Value Display 20Receive1 Bit1.3 enableCWTU
1071 Bit Value Display 20Receive1 Bit1.5 alarmCWTU
1071 Bit Value Display 20Receive1 Bit1.6 binary valueCWTU
1071 Bit Value Display 20Receive1 Bit1.9 open/closeCWTU
1071 Bit Value Display 20Receive1 Bit1.11 stateCWTU
1071 Bit Value Display 20Receive1 Bit1.18 occupancyCWTU
1071 Bit Value Display 20Receive1 Bit1.19 window/doorCWTU
1082 Bit Switch controlled 1Transmit2 Bit2.1 switch controlCT
1082 Bit Switch controlled 1Transmit2 Bit2.8 direction control 1CT
1092 Bit Switch controlled 2Transmit2 Bit2.1 switch controlCT
1092 Bit Switch controlled 2Transmit2 Bit2.8 direction control 1CT
1102 Bit Switch controlled 3Transmit2 Bit2.1 switch controlCT
1102 Bit Switch controlled 3Transmit2 Bit2.8 direction control 1CT
1112 Bit Switch controlled 4Transmit2 Bit2.1 switch controlCT
1112 Bit Switch controlled 4Transmit2 Bit2.8 direction control 1CT
1122 Bit Switch controlled 5Transmit2 Bit2.1 switch controlCT
1122 Bit Switch controlled 5Transmit2 Bit2.8 direction control 1CT
1131 Byte Value Display 1Receive1 Byte5.1 percentage (0..100%)CWTU
1131 Byte Value Display 1Receive1 Byte5.4 percentage (0..255%)CWTU
1131 Byte Value Display 1Receive1 Byte5.10 counter pulses (0..255)CWTU
1131 Byte Value Display 1Receive1 Byte6.1 percentage (-128..127%)CWTU
1131 Byte Value Display 1Receive1 Byte6.10 counter pulses (-128..127)CWTU
1131 Byte Value Display 1Receive1 Byte20.2 building modeCWTU
1131 Byte Value Display 1Receive1 Byte20.3 occupiedCWTU
1131 Byte Value Display 1Receive1 Byte20.102 HVAC modeCWTU
1131 Byte Value Display 1Receive1 Byte20.103 DHW modeCWTU
1131 Byte Value Display 1Receive1 Byte20.105 HVAC control modeCWTU
1131 Byte Value Display 1Receive1 Byte20.107 changeover modeCWTU
1141 Byte Value Display 2Receive1 Byte5.1 percentage (0..100%)CWTU
1141 Byte Value Display 2Receive1 Byte5.4 percentage (0..255%)CWTU
1141 Byte Value Display 2Receive1 Byte5.10 counter pulses (0..255)CWTU
1141 Byte Value Display 2Receive1 Byte6.1 percentage (-128..127%)CWTU
1141 Byte Value Display 2Receive1 Byte6.10 counter pulses (-128..127)CWTU
1141 Byte Value Display 2Receive1 Byte20.2 building modeCWTU
1141 Byte Value Display 2Receive1 Byte20.3 occupiedCWTU
1141 Byte Value Display 2Receive1 Byte20.102 HVAC modeCWTU
1141 Byte Value Display 2Receive1 Byte20.103 DHW modeCWTU
1141 Byte Value Display 2Receive1 Byte20.105 HVAC control modeCWTU
1141 Byte Value Display 2Receive1 Byte20.107 changeover modeCWTU
1151 Byte Value Display 3Receive1 Byte5.1 percentage (0..100%)CWTU
1151 Byte Value Display 3Receive1 Byte5.4 percentage (0..255%)CWTU
1151 Byte Value Display 3Receive1 Byte5.10 counter pulses (0..255)CWTU
1151 Byte Value Display 3Receive1 Byte6.1 percentage (-128..127%)CWTU
1151 Byte Value Display 3Receive1 Byte6.10 counter pulses (-128..127)CWTU
1151 Byte Value Display 3Receive1 Byte20.2 building modeCWTU
1151 Byte Value Display 3Receive1 Byte20.3 occupiedCWTU
1151 Byte Value Display 3Receive1 Byte20.102 HVAC modeCWTU
1151 Byte Value Display 3Receive1 Byte20.103 DHW modeCWTU
1151 Byte Value Display 3Receive1 Byte20.105 HVAC control modeCWTU
1151 Byte Value Display 3Receive1 Byte20.107 changeover modeCWTU
1161 Byte Value Display 4Receive1 Byte5.1 percentage (0..100%)CWTU
1161 Byte Value Display 4Receive1 Byte5.4 percentage (0..255%)CWTU
1161 Byte Value Display 4Receive1 Byte5.10 counter pulses (0..255)CWTU
1161 Byte Value Display 4Receive1 Byte6.1 percentage (-128..127%)CWTU
1161 Byte Value Display 4Receive1 Byte6.10 counter pulses (-128..127)CWTU
1161 Byte Value Display 4Receive1 Byte20.2 building modeCWTU
1161 Byte Value Display 4Receive1 Byte20.3 occupiedCWTU
1161 Byte Value Display 4Receive1 Byte20.102 HVAC modeCWTU
1161 Byte Value Display 4Receive1 Byte20.103 DHW modeCWTU
1161 Byte Value Display 4Receive1 Byte20.105 HVAC control modeCWTU
1161 Byte Value Display 4Receive1 Byte20.107 changeover modeCWTU
1171 Byte Value Display 5Receive1 Byte5.1 percentage (0..100%)CWTU
1171 Byte Value Display 5Receive1 Byte5.4 percentage (0..255%)CWTU
1171 Byte Value Display 5Receive1 Byte5.10 counter pulses (0..255)CWTU
1171 Byte Value Display 5Receive1 Byte6.1 percentage (-128..127%)CWTU
1171 Byte Value Display 5Receive1 Byte6.10 counter pulses (-128..127)CWTU
1171 Byte Value Display 5Receive1 Byte20.2 building modeCWTU
1171 Byte Value Display 5Receive1 Byte20.3 occupiedCWTU
1171 Byte Value Display 5Receive1 Byte20.102 HVAC modeCWTU
1171 Byte Value Display 5Receive1 Byte20.103 DHW modeCWTU
1171 Byte Value Display 5Receive1 Byte20.105 HVAC control modeCWTU
1171 Byte Value Display 5Receive1 Byte20.107 changeover modeCWTU
1181 Byte Value Display 6Receive1 Byte5.1 percentage (0..100%)CWTU
1181 Byte Value Display 6Receive1 Byte5.4 percentage (0..255%)CWTU
1181 Byte Value Display 6Receive1 Byte5.10 counter pulses (0..255)CWTU
1181 Byte Value Display 6Receive1 Byte6.1 percentage (-128..127%)CWTU
1181 Byte Value Display 6Receive1 Byte6.10 counter pulses (-128..127)CWTU
1181 Byte Value Display 6Receive1 Byte20.2 building modeCWTU
1181 Byte Value Display 6Receive1 Byte20.3 occupiedCWTU
1181 Byte Value Display 6Receive1 Byte20.102 HVAC modeCWTU
1181 Byte Value Display 6Receive1 Byte20.103 DHW modeCWTU
1181 Byte Value Display 6Receive1 Byte20.105 HVAC control modeCWTU
1181 Byte Value Display 6Receive1 Byte20.107 changeover modeCWTU
1191 Byte Value Display 7Receive1 Byte5.1 percentage (0..100%)CWTU
1191 Byte Value Display 7Receive1 Byte5.4 percentage (0..255%)CWTU
1191 Byte Value Display 7Receive1 Byte5.10 counter pulses (0..255)CWTU
1191 Byte Value Display 7Receive1 Byte6.1 percentage (-128..127%)CWTU
1191 Byte Value Display 7Receive1 Byte6.10 counter pulses (-128..127)CWTU
1191 Byte Value Display 7Receive1 Byte20.2 building modeCWTU
1191 Byte Value Display 7Receive1 Byte20.3 occupiedCWTU
1191 Byte Value Display 7Receive1 Byte20.102 HVAC modeCWTU
1191 Byte Value Display 7Receive1 Byte20.103 DHW modeCWTU
1191 Byte Value Display 7Receive1 Byte20.105 HVAC control modeCWTU
1191 Byte Value Display 7Receive1 Byte20.107 changeover modeCWTU
1201 Byte Value Display 8Receive1 Byte5.1 percentage (0..100%)CWTU
1201 Byte Value Display 8Receive1 Byte5.4 percentage (0..255%)CWTU
1201 Byte Value Display 8Receive1 Byte5.10 counter pulses (0..255)CWTU
1201 Byte Value Display 8Receive1 Byte6.1 percentage (-128..127%)CWTU
1201 Byte Value Display 8Receive1 Byte6.10 counter pulses (-128..127)CWTU
1201 Byte Value Display 8Receive1 Byte20.2 building modeCWTU
1201 Byte Value Display 8Receive1 Byte20.3 occupiedCWTU
1201 Byte Value Display 8Receive1 Byte20.102 HVAC modeCWTU
1201 Byte Value Display 8Receive1 Byte20.103 DHW modeCWTU
1201 Byte Value Display 8Receive1 Byte20.105 HVAC control modeCWTU
1201 Byte Value Display 8Receive1 Byte20.107 changeover modeCWTU
1211 Byte Value Display 9Receive1 Byte5.1 percentage (0..100%)CWTU
1211 Byte Value Display 9Receive1 Byte5.4 percentage (0..255%)CWTU
1211 Byte Value Display 9Receive1 Byte5.10 counter pulses (0..255)CWTU
1211 Byte Value Display 9Receive1 Byte6.1 percentage (-128..127%)CWTU
1211 Byte Value Display 9Receive1 Byte6.10 counter pulses (-128..127)CWTU
1211 Byte Value Display 9Receive1 Byte20.2 building modeCWTU
1211 Byte Value Display 9Receive1 Byte20.3 occupiedCWTU
1211 Byte Value Display 9Receive1 Byte20.102 HVAC modeCWTU
1211 Byte Value Display 9Receive1 Byte20.103 DHW modeCWTU
1211 Byte Value Display 9Receive1 Byte20.105 HVAC control modeCWTU
1211 Byte Value Display 9Receive1 Byte20.107 changeover modeCWTU
1221 Byte Value Display 10Receive1 Byte5.1 percentage (0..100%)CWTU
1221 Byte Value Display 10Receive1 Byte5.4 percentage (0..255%)CWTU
1221 Byte Value Display 10Receive1 Byte5.10 counter pulses (0..255)CWTU
1221 Byte Value Display 10Receive1 Byte6.1 percentage (-128..127%)CWTU
1221 Byte Value Display 10Receive1 Byte6.10 counter pulses (-128..127)CWTU
1221 Byte Value Display 10Receive1 Byte20.2 building modeCWTU
1221 Byte Value Display 10Receive1 Byte20.3 occupiedCWTU
1221 Byte Value Display 10Receive1 Byte20.102 HVAC modeCWTU
1221 Byte Value Display 10Receive1 Byte20.103 DHW modeCWTU
1221 Byte Value Display 10Receive1 Byte20.105 HVAC control modeCWTU
1221 Byte Value Display 10Receive1 Byte20.107 changeover modeCWTU
1231 Byte Value Display 11Receive1 Byte5.1 percentage (0..100%)CWTU
1231 Byte Value Display 11Receive1 Byte5.4 percentage (0..255%)CWTU
1231 Byte Value Display 11Receive1 Byte5.10 counter pulses (0..255)CWTU
1231 Byte Value Display 11Receive1 Byte6.1 percentage (-128..127%)CWTU
1231 Byte Value Display 11Receive1 Byte6.10 counter pulses (-128..127)CWTU
1231 Byte Value Display 11Receive1 Byte20.2 building modeCWTU
1231 Byte Value Display 11Receive1 Byte20.3 occupiedCWTU
1231 Byte Value Display 11Receive1 Byte20.102 HVAC modeCWTU
1231 Byte Value Display 11Receive1 Byte20.103 DHW modeCWTU
1231 Byte Value Display 11Receive1 Byte20.105 HVAC control modeCWTU
1231 Byte Value Display 11Receive1 Byte20.107 changeover modeCWTU
1241 Byte Value Display 12Receive1 Byte5.1 percentage (0..100%)CWTU
1241 Byte Value Display 12Receive1 Byte5.4 percentage (0..255%)CWTU
1241 Byte Value Display 12Receive1 Byte5.10 counter pulses (0..255)CWTU
1241 Byte Value Display 12Receive1 Byte6.1 percentage (-128..127%)CWTU
1241 Byte Value Display 12Receive1 Byte6.10 counter pulses (-128..127)CWTU
1241 Byte Value Display 12Receive1 Byte20.2 building modeCWTU
1241 Byte Value Display 12Receive1 Byte20.3 occupiedCWTU
1241 Byte Value Display 12Receive1 Byte20.102 HVAC modeCWTU
1241 Byte Value Display 12Receive1 Byte20.103 DHW modeCWTU
1241 Byte Value Display 12Receive1 Byte20.105 HVAC control modeCWTU
1241 Byte Value Display 12Receive1 Byte20.107 changeover modeCWTU
1251 Byte Value Display 13Receive1 Byte5.1 percentage (0..100%)CWTU
1251 Byte Value Display 13Receive1 Byte5.4 percentage (0..255%)CWTU
1251 Byte Value Display 13Receive1 Byte5.10 counter pulses (0..255)CWTU
1251 Byte Value Display 13Receive1 Byte6.1 percentage (-128..127%)CWTU
1251 Byte Value Display 13Receive1 Byte6.10 counter pulses (-128..127)CWTU
1251 Byte Value Display 13Receive1 Byte20.2 building modeCWTU
1251 Byte Value Display 13Receive1 Byte20.3 occupiedCWTU
1251 Byte Value Display 13Receive1 Byte20.102 HVAC modeCWTU
1251 Byte Value Display 13Receive1 Byte20.103 DHW modeCWTU
1251 Byte Value Display 13Receive1 Byte20.105 HVAC control modeCWTU
1251 Byte Value Display 13Receive1 Byte20.107 changeover modeCWTU
1261 Byte Value Display 14Receive1 Byte5.1 percentage (0..100%)CWTU
1261 Byte Value Display 14Receive1 Byte5.4 percentage (0..255%)CWTU
1261 Byte Value Display 14Receive1 Byte5.10 counter pulses (0..255)CWTU
1261 Byte Value Display 14Receive1 Byte6.1 percentage (-128..127%)CWTU
1261 Byte Value Display 14Receive1 Byte6.10 counter pulses (-128..127)CWTU
1261 Byte Value Display 14Receive1 Byte20.2 building modeCWTU
1261 Byte Value Display 14Receive1 Byte20.3 occupiedCWTU
1261 Byte Value Display 14Receive1 Byte20.102 HVAC modeCWTU
1261 Byte Value Display 14Receive1 Byte20.103 DHW modeCWTU
1261 Byte Value Display 14Receive1 Byte20.105 HVAC control modeCWTU
1261 Byte Value Display 14Receive1 Byte20.107 changeover modeCWTU
1271 Byte Value Display 15Receive1 Byte5.1 percentage (0..100%)CWTU
1271 Byte Value Display 15Receive1 Byte5.4 percentage (0..255%)CWTU
1271 Byte Value Display 15Receive1 Byte5.10 counter pulses (0..255)CWTU
1271 Byte Value Display 15Receive1 Byte6.1 percentage (-128..127%)CWTU
1271 Byte Value Display 15Receive1 Byte6.10 counter pulses (-128..127)CWTU
1271 Byte Value Display 15Receive1 Byte20.2 building modeCWTU
1271 Byte Value Display 15Receive1 Byte20.3 occupiedCWTU
1271 Byte Value Display 15Receive1 Byte20.102 HVAC modeCWTU
1271 Byte Value Display 15Receive1 Byte20.103 DHW modeCWTU
1271 Byte Value Display 15Receive1 Byte20.105 HVAC control modeCWTU
1271 Byte Value Display 15Receive1 Byte20.107 changeover modeCWTU
1281 Byte Value Display 16Receive1 Byte5.1 percentage (0..100%)CWTU
1281 Byte Value Display 16Receive1 Byte5.4 percentage (0..255%)CWTU
1281 Byte Value Display 16Receive1 Byte5.10 counter pulses (0..255)CWTU
1281 Byte Value Display 16Receive1 Byte6.1 percentage (-128..127%)CWTU
1281 Byte Value Display 16Receive1 Byte6.10 counter pulses (-128..127)CWTU
1281 Byte Value Display 16Receive1 Byte20.2 building modeCWTU
1281 Byte Value Display 16Receive1 Byte20.3 occupiedCWTU
1281 Byte Value Display 16Receive1 Byte20.102 HVAC modeCWTU
1281 Byte Value Display 16Receive1 Byte20.103 DHW modeCWTU
1281 Byte Value Display 16Receive1 Byte20.105 HVAC control modeCWTU
1281 Byte Value Display 16Receive1 Byte20.107 changeover modeCWTU
1291 Byte Value Display 17Receive1 Byte5.1 percentage (0..100%)CWTU
1291 Byte Value Display 17Receive1 Byte5.4 percentage (0..255%)CWTU
1291 Byte Value Display 17Receive1 Byte5.10 counter pulses (0..255)CWTU
1291 Byte Value Display 17Receive1 Byte6.1 percentage (-128..127%)CWTU
1291 Byte Value Display 17Receive1 Byte6.10 counter pulses (-128..127)CWTU
1291 Byte Value Display 17Receive1 Byte20.2 building modeCWTU
1291 Byte Value Display 17Receive1 Byte20.3 occupiedCWTU
1291 Byte Value Display 17Receive1 Byte20.102 HVAC modeCWTU
1291 Byte Value Display 17Receive1 Byte20.103 DHW modeCWTU
1291 Byte Value Display 17Receive1 Byte20.105 HVAC control modeCWTU
1291 Byte Value Display 17Receive1 Byte20.107 changeover modeCWTU
1301 Byte Value Display 18Receive1 Byte5.1 percentage (0..100%)CWTU
1301 Byte Value Display 18Receive1 Byte5.4 percentage (0..255%)CWTU
1301 Byte Value Display 18Receive1 Byte5.10 counter pulses (0..255)CWTU
1301 Byte Value Display 18Receive1 Byte6.1 percentage (-128..127%)CWTU
1301 Byte Value Display 18Receive1 Byte6.10 counter pulses (-128..127)CWTU
1301 Byte Value Display 18Receive1 Byte20.2 building modeCWTU
1301 Byte Value Display 18Receive1 Byte20.3 occupiedCWTU
1301 Byte Value Display 18Receive1 Byte20.102 HVAC modeCWTU
1301 Byte Value Display 18Receive1 Byte20.103 DHW modeCWTU
1301 Byte Value Display 18Receive1 Byte20.105 HVAC control modeCWTU
1301 Byte Value Display 18Receive1 Byte20.107 changeover modeCWTU
1311 Byte Value Display 19Receive1 Byte5.1 percentage (0..100%)CWTU
1311 Byte Value Display 19Receive1 Byte5.4 percentage (0..255%)CWTU
1311 Byte Value Display 19Receive1 Byte5.10 counter pulses (0..255)CWTU
1311 Byte Value Display 19Receive1 Byte6.1 percentage (-128..127%)CWTU
1311 Byte Value Display 19Receive1 Byte6.10 counter pulses (-128..127)CWTU
1311 Byte Value Display 19Receive1 Byte20.2 building modeCWTU
1311 Byte Value Display 19Receive1 Byte20.3 occupiedCWTU
1311 Byte Value Display 19Receive1 Byte20.102 HVAC modeCWTU
1311 Byte Value Display 19Receive1 Byte20.103 DHW modeCWTU
1311 Byte Value Display 19Receive1 Byte20.105 HVAC control modeCWTU
1311 Byte Value Display 19Receive1 Byte20.107 changeover modeCWTU
1321 Byte Value Display 20Receive1 Byte5.1 percentage (0..100%)CWTU
1321 Byte Value Display 20Receive1 Byte5.4 percentage (0..255%)CWTU
1321 Byte Value Display 20Receive1 Byte5.10 counter pulses (0..255)CWTU
1321 Byte Value Display 20Receive1 Byte6.1 percentage (-128..127%)CWTU
1321 Byte Value Display 20Receive1 Byte6.10 counter pulses (-128..127)CWTU
1321 Byte Value Display 20Receive1 Byte20.2 building modeCWTU
1321 Byte Value Display 20Receive1 Byte20.3 occupiedCWTU
1321 Byte Value Display 20Receive1 Byte20.102 HVAC modeCWTU
1321 Byte Value Display 20Receive1 Byte20.103 DHW modeCWTU
1321 Byte Value Display 20Receive1 Byte20.105 HVAC control modeCWTU
1321 Byte Value Display 20Receive1 Byte20.107 changeover modeCWTU
1331 Byte Value Change+Display 1Receive and Transmit1 Byte5.1 percentage (0..100%)CRWTU
1331 Byte Value Change+Display 1Receive and Transmit1 Byte5.4 percentage (0..255%)CRWTU
1331 Byte Value Change+Display 1Receive and Transmit1 Byte5.10 counter pulses (0..255)CRWTU
1331 Byte Value Change+Display 1Receive and Transmit1 Byte6.1 percentage (-128..127%)CRWTU
1331 Byte Value Change+Display 1Receive and Transmit1 Byte6.10 counter pulses (-128..127)CRWTU
1331 Byte Value Change+Display 1Receive and Transmit1 Byte20.2 building modeCRWTU
1331 Byte Value Change+Display 1Receive and Transmit1 Byte20.3 occupiedCRWTU
1331 Byte Value Change+Display 1Receive and Transmit1 Byte20.102 HVAC modeCRWTU
1331 Byte Value Change+Display 1Receive and Transmit1 Byte20.103 DHW modeCRWTU
1331 Byte Value Change+Display 1Receive and Transmit1 Byte20.105 HVAC control modeCRWTU
1331 Byte Value Change+Display 1Receive and Transmit1 Byte20.107 changeover modeCRWTU
1341 Byte Value Change+Display 2Receive and Transmit1 Byte5.1 percentage (0..100%)CRWTU
1341 Byte Value Change+Display 2Receive and Transmit1 Byte5.4 percentage (0..255%)CRWTU
1341 Byte Value Change+Display 2Receive and Transmit1 Byte5.10 counter pulses (0..255)CRWTU
1341 Byte Value Change+Display 2Receive and Transmit1 Byte6.1 percentage (-128..127%)CRWTU
1341 Byte Value Change+Display 2Receive and Transmit1 Byte6.10 counter pulses (-128..127)CRWTU
1341 Byte Value Change+Display 2Receive and Transmit1 Byte20.2 building modeCRWTU
1341 Byte Value Change+Display 2Receive and Transmit1 Byte20.3 occupiedCRWTU
1341 Byte Value Change+Display 2Receive and Transmit1 Byte20.102 HVAC modeCRWTU
1341 Byte Value Change+Display 2Receive and Transmit1 Byte20.103 DHW modeCRWTU
1341 Byte Value Change+Display 2Receive and Transmit1 Byte20.105 HVAC control modeCRWTU
1341 Byte Value Change+Display 2Receive and Transmit1 Byte20.107 changeover modeCRWTU
1351 Byte Value Change+Display 3Receive and Transmit1 Byte5.1 percentage (0..100%)CRWTU
1351 Byte Value Change+Display 3Receive and Transmit1 Byte5.4 percentage (0..255%)CRWTU
1351 Byte Value Change+Display 3Receive and Transmit1 Byte5.10 counter pulses (0..255)CRWTU
1351 Byte Value Change+Display 3Receive and Transmit1 Byte6.1 percentage (-128..127%)CRWTU
1351 Byte Value Change+Display 3Receive and Transmit1 Byte6.10 counter pulses (-128..127)CRWTU
1351 Byte Value Change+Display 3Receive and Transmit1 Byte20.2 building modeCRWTU
1351 Byte Value Change+Display 3Receive and Transmit1 Byte20.3 occupiedCRWTU
1351 Byte Value Change+Display 3Receive and Transmit1 Byte20.102 HVAC modeCRWTU
1351 Byte Value Change+Display 3Receive and Transmit1 Byte20.103 DHW modeCRWTU
1351 Byte Value Change+Display 3Receive and Transmit1 Byte20.105 HVAC control modeCRWTU
1351 Byte Value Change+Display 3Receive and Transmit1 Byte20.107 changeover modeCRWTU
1361 Byte Value Change+Display 4Receive and Transmit1 Byte5.1 percentage (0..100%)CRWTU
1361 Byte Value Change+Display 4Receive and Transmit1 Byte5.4 percentage (0..255%)CRWTU
1361 Byte Value Change+Display 4Receive and Transmit1 Byte5.10 counter pulses (0..255)CRWTU
1361 Byte Value Change+Display 4Receive and Transmit1 Byte6.1 percentage (-128..127%)CRWTU
1361 Byte Value Change+Display 4Receive and Transmit1 Byte6.10 counter pulses (-128..127)CRWTU
1361 Byte Value Change+Display 4Receive and Transmit1 Byte20.2 building modeCRWTU
1361 Byte Value Change+Display 4Receive and Transmit1 Byte20.3 occupiedCRWTU
1361 Byte Value Change+Display 4Receive and Transmit1 Byte20.102 HVAC modeCRWTU
1361 Byte Value Change+Display 4Receive and Transmit1 Byte20.103 DHW modeCRWTU
1361 Byte Value Change+Display 4Receive and Transmit1 Byte20.105 HVAC control modeCRWTU
1361 Byte Value Change+Display 4Receive and Transmit1 Byte20.107 changeover modeCRWTU
1371 Byte Value Change+Display 5Receive and Transmit1 Byte5.1 percentage (0..100%)CRWTU
1371 Byte Value Change+Display 5Receive and Transmit1 Byte5.4 percentage (0..255%)CRWTU
1371 Byte Value Change+Display 5Receive and Transmit1 Byte5.10 counter pulses (0..255)CRWTU
1371 Byte Value Change+Display 5Receive and Transmit1 Byte6.1 percentage (-128..127%)CRWTU
1371 Byte Value Change+Display 5Receive and Transmit1 Byte6.10 counter pulses (-128..127)CRWTU
1371 Byte Value Change+Display 5Receive and Transmit1 Byte20.2 building modeCRWTU
1371 Byte Value Change+Display 5Receive and Transmit1 Byte20.3 occupiedCRWTU
1371 Byte Value Change+Display 5Receive and Transmit1 Byte20.102 HVAC modeCRWTU
1371 Byte Value Change+Display 5Receive and Transmit1 Byte20.103 DHW modeCRWTU
1371 Byte Value Change+Display 5Receive and Transmit1 Byte20.105 HVAC control modeCRWTU
1371 Byte Value Change+Display 5Receive and Transmit1 Byte20.107 changeover modeCRWTU
1381 Byte Value Change+Display 6Receive and Transmit1 Byte5.1 percentage (0..100%)CRWTU
1381 Byte Value Change+Display 6Receive and Transmit1 Byte5.4 percentage (0..255%)CRWTU
1381 Byte Value Change+Display 6Receive and Transmit1 Byte5.10 counter pulses (0..255)CRWTU
1381 Byte Value Change+Display 6Receive and Transmit1 Byte6.1 percentage (-128..127%)CRWTU
1381 Byte Value Change+Display 6Receive and Transmit1 Byte6.10 counter pulses (-128..127)CRWTU
1381 Byte Value Change+Display 6Receive and Transmit1 Byte20.2 building modeCRWTU
1381 Byte Value Change+Display 6Receive and Transmit1 Byte20.3 occupiedCRWTU
1381 Byte Value Change+Display 6Receive and Transmit1 Byte20.102 HVAC modeCRWTU
1381 Byte Value Change+Display 6Receive and Transmit1 Byte20.103 DHW modeCRWTU
1381 Byte Value Change+Display 6Receive and Transmit1 Byte20.105 HVAC control modeCRWTU
1381 Byte Value Change+Display 6Receive and Transmit1 Byte20.107 changeover modeCRWTU
1391 Byte Value Change+Display 7Receive and Transmit1 Byte5.1 percentage (0..100%)CRWTU
1391 Byte Value Change+Display 7Receive and Transmit1 Byte5.4 percentage (0..255%)CRWTU
1391 Byte Value Change+Display 7Receive and Transmit1 Byte5.10 counter pulses (0..255)CRWTU
1391 Byte Value Change+Display 7Receive and Transmit1 Byte6.1 percentage (-128..127%)CRWTU
1391 Byte Value Change+Display 7Receive and Transmit1 Byte6.10 counter pulses (-128..127)CRWTU
1391 Byte Value Change+Display 7Receive and Transmit1 Byte20.2 building modeCRWTU
1391 Byte Value Change+Display 7Receive and Transmit1 Byte20.3 occupiedCRWTU
1391 Byte Value Change+Display 7Receive and Transmit1 Byte20.102 HVAC modeCRWTU
1391 Byte Value Change+Display 7Receive and Transmit1 Byte20.103 DHW modeCRWTU
1391 Byte Value Change+Display 7Receive and Transmit1 Byte20.105 HVAC control modeCRWTU
1391 Byte Value Change+Display 7Receive and Transmit1 Byte20.107 changeover modeCRWTU
1401 Byte Value Change+Display 8Receive and Transmit1 Byte5.1 percentage (0..100%)CRWTU
1401 Byte Value Change+Display 8Receive and Transmit1 Byte5.4 percentage (0..255%)CRWTU
1401 Byte Value Change+Display 8Receive and Transmit1 Byte5.10 counter pulses (0..255)CRWTU
1401 Byte Value Change+Display 8Receive and Transmit1 Byte6.1 percentage (-128..127%)CRWTU
1401 Byte Value Change+Display 8Receive and Transmit1 Byte6.10 counter pulses (-128..127)CRWTU
1401 Byte Value Change+Display 8Receive and Transmit1 Byte20.2 building modeCRWTU
1401 Byte Value Change+Display 8Receive and Transmit1 Byte20.3 occupiedCRWTU
1401 Byte Value Change+Display 8Receive and Transmit1 Byte20.102 HVAC modeCRWTU
1401 Byte Value Change+Display 8Receive and Transmit1 Byte20.103 DHW modeCRWTU
1401 Byte Value Change+Display 8Receive and Transmit1 Byte20.105 HVAC control modeCRWTU
1401 Byte Value Change+Display 8Receive and Transmit1 Byte20.107 changeover modeCRWTU
1411 Byte Value Change+Display 9Receive and Transmit1 Byte5.1 percentage (0..100%)CRWTU
1411 Byte Value Change+Display 9Receive and Transmit1 Byte5.4 percentage (0..255%)CRWTU
1411 Byte Value Change+Display 9Receive and Transmit1 Byte5.10 counter pulses (0..255)CRWTU
1411 Byte Value Change+Display 9Receive and Transmit1 Byte6.1 percentage (-128..127%)CRWTU
1411 Byte Value Change+Display 9Receive and Transmit1 Byte6.10 counter pulses (-128..127)CRWTU
1411 Byte Value Change+Display 9Receive and Transmit1 Byte20.2 building modeCRWTU
1411 Byte Value Change+Display 9Receive and Transmit1 Byte20.3 occupiedCRWTU
1411 Byte Value Change+Display 9Receive and Transmit1 Byte20.102 HVAC modeCRWTU
1411 Byte Value Change+Display 9Receive and Transmit1 Byte20.103 DHW modeCRWTU
1411 Byte Value Change+Display 9Receive and Transmit1 Byte20.105 HVAC control modeCRWTU
1411 Byte Value Change+Display 9Receive and Transmit1 Byte20.107 changeover modeCRWTU
1421 Byte Value Change+Display 10Receive and Transmit1 Byte5.1 percentage (0..100%)CRWTU
1421 Byte Value Change+Display 10Receive and Transmit1 Byte5.4 percentage (0..255%)CRWTU
1421 Byte Value Change+Display 10Receive and Transmit1 Byte5.10 counter pulses (0..255)CRWTU
1421 Byte Value Change+Display 10Receive and Transmit1 Byte6.1 percentage (-128..127%)CRWTU
1421 Byte Value Change+Display 10Receive and Transmit1 Byte6.10 counter pulses (-128..127)CRWTU
1421 Byte Value Change+Display 10Receive and Transmit1 Byte20.2 building modeCRWTU
1421 Byte Value Change+Display 10Receive and Transmit1 Byte20.3 occupiedCRWTU
1421 Byte Value Change+Display 10Receive and Transmit1 Byte20.102 HVAC modeCRWTU
1421 Byte Value Change+Display 10Receive and Transmit1 Byte20.103 DHW modeCRWTU
1421 Byte Value Change+Display 10Receive and Transmit1 Byte20.105 HVAC control modeCRWTU
1421 Byte Value Change+Display 10Receive and Transmit1 Byte20.107 changeover modeCRWTU
1431 Byte Value Change+Display 11Receive and Transmit1 Byte5.1 percentage (0..100%)CRWTU
1431 Byte Value Change+Display 11Receive and Transmit1 Byte5.4 percentage (0..255%)CRWTU
1431 Byte Value Change+Display 11Receive and Transmit1 Byte5.10 counter pulses (0..255)CRWTU
1431 Byte Value Change+Display 11Receive and Transmit1 Byte6.1 percentage (-128..127%)CRWTU
1431 Byte Value Change+Display 11Receive and Transmit1 Byte6.10 counter pulses (-128..127)CRWTU
1431 Byte Value Change+Display 11Receive and Transmit1 Byte20.2 building modeCRWTU
1431 Byte Value Change+Display 11Receive and Transmit1 Byte20.3 occupiedCRWTU
1431 Byte Value Change+Display 11Receive and Transmit1 Byte20.102 HVAC modeCRWTU
1431 Byte Value Change+Display 11Receive and Transmit1 Byte20.103 DHW modeCRWTU
1431 Byte Value Change+Display 11Receive and Transmit1 Byte20.105 HVAC control modeCRWTU
1431 Byte Value Change+Display 11Receive and Transmit1 Byte20.107 changeover modeCRWTU
1441 Byte Value Change+Display 12Receive and Transmit1 Byte5.1 percentage (0..100%)CRWTU
1441 Byte Value Change+Display 12Receive and Transmit1 Byte5.4 percentage (0..255%)CRWTU

First 1000 of 2262 group objects shown. Download the .knxprod for the full list.

Parameters (2000)
ParameterTypeDefault
Page name 1textPage name 1
Page name 2textPage name 2
Page name 3textPage name 3
Page name 4textPage name 4
Page name 5textPage name 5
Page name 6textPage name 6
Page name 7textPage name 7
Page name 8textPage name 8
Page name 9textPage name 9
Page name 10textPage name 10
Value 1 (Change)listNo
Data point typelist1.001 Off/On
Data point name 1text1 Bit Value Change/Display 1
Web server pagelistPage 1
Value 2 (Display)listNo
Data point name 2text1 Bit Value Change/Display 2
Value 3 (Change)listNo
Data point name 3text1 Bit Value Change/Display 3
Value 4 (Display)listNo
Data point name 4text1 Bit Value Change/Display 4
Value 5 (Change)listNo
Data point name 5text1 Bit Value Change/Display 5
Value 6 (Display)listNo
Data point name 6text1 Bit Value Change/Display 6
Value 7 (Change)listNo
Data point name 7text1 Bit Value Change/Display 7
Value 8 (Display)listNo
Data point name 8text1 Bit Value Change/Display 8
Value 9 (Change)listNo
Data point name 9text1 Bit Value Change/Display 9
Value 10 (Display)listNo
Data point name 10text1 Bit Value Change/Display 10
Value 11 (Change)listNo
Data point name 11text1 Bit Value Change/Display 11
Value 12 (Display)listNo
Data point name 12text1 Bit Value Change/Display 12
Value 13 (Change)listNo
Data point name 13text1 Bit Value Change/Display 13
Value 14 (Display)listNo
Data point name 14text1 Bit Value Change/Display 14
Value 15 (Change)listNo
Data point name 15text1 Bit Value Change/Display 15
Value 16 (Display)listNo
Data point name 16text1 Bit Value Change/Display 16
Value 17 (Change)listNo
Data point name 17text1 Bit Value Change/Display 17
Value 18 (Display)listNo
Data point name 18text1 Bit Value Change/Display 18
Value 19 (Change)listNo
Data point name 19text1 Bit Value Change/Display 19
Value 20 (Display)listNo
Data point name 20text1 Bit Value Change/Display 20
Value 21 (Change)listNo
Data point name 21text1 Bit Value Change/Display 21
Value 22 (Display)listNo
Data point name 22text1 Bit Value Change/Display 22
Value 23 (Change)listNo
Data point name 23text1 Bit Value Change/Display 23
Value 24 (Display)listNo
Data point name 24text1 Bit Value Change/Display 24
Value 25 (Change)listNo
Data point name 25text1 Bit Value Change/Display 25
Value 26 (Display)listNo
Data point name 26text1 Bit Value Change/Display 26
Value 27 (Change)listNo
Data point name 27text1 Bit Value Change/Display 27
Value 28 (Display)listNo
Data point name 28text1 Bit Value Change/Display 28
Value 29 (Change)listNo
Data point name 29text1 Bit Value Change/Display 29
Value 30 (Display)listNo
Data point name 30text1 Bit Value Change/Display 30
Value 31 (Change)listNo
Data point name 31text1 Bit Value Change/Display 31
Value 32 (Display)listNo
Data point name 32text1 Bit Value Change/Display 32
Value 33 (Change)listNo
Data point name 33text1 Bit Value Change/Display 33
Value 34 (Display)listNo
Data point name 34text1 Bit Value Change/Display 34
Value 35 (Change)listNo
Data point name 35text1 Bit Value Change/Display 35
Value 36 (Display)listNo
Data point name 36text1 Bit Value Change/Display 36
Value 37 (Change)listNo
Data point name 37text1 Bit Value Change/Display 37
Value 38 (Display)listNo
Data point name 38text1 Bit Value Change/Display 38
Value 39 (Change)listNo
Data point name 39text1 Bit Value Change/Display 39
Value 40 (Display)listNo
Data point name 40text1 Bit Value Change/Display 40
Data point name 1text1 Bit Value Change 1
Value 2 (Change)listNo
Data point name 2text1 Bit Value Change 2
Data point name 3text1 Bit Value Change 3
Value 4 (Change)listNo
Data point name 4text1 Bit Value Change 4
Data point name 5text1 Bit Value Change 5
Value 6 (Change)listNo
Data point name 6text1 Bit Value Change 6
Data point name 7text1 Bit Value Change 7
Value 8 (Change)listNo
Data point name 8text1 Bit Value Change 8
Data point name 9text1 Bit Value Change 9
Value 10 (Change)listNo
Data point name 10text1 Bit Value Change 10
Data point name 11text1 Bit Value Change 11
Value 12 (Change)listNo
Data point name 12text1 Bit Value Change 12
Data point name 13text1 Bit Value Change 13
Value 14 (Change)listNo
Data point name 14text1 Bit Value Change 14
Data point name 15text1 Bit Value Change 15
Value 16 (Change)listNo
Data point name 16text1 Bit Value Change 16
Data point name 17text1 Bit Value Change 17
Value 18 (Change)listNo
Data point name 18text1 Bit Value Change 18
Data point name 19text1 Bit Value Change 19
Value 20 (Change)listNo
Data point name 20text1 Bit Value Change 20
Data point typelist1.007 Decrease/Increase
Data point name 1text1 Bit Blind 1
Data point name 2text1 Bit Blind 2
Data point name 3text1 Bit Blind 3
Data point name 4text1 Bit Blind 4
Data point name 5text1 Bit Blind 5
Data point name 6text1 Bit Blind 6
Data point name 7text1 Bit Blind 7
Data point name 8text1 Bit Blind 8
Data point name 9text1 Bit Blind 9
Data point name 10text1 Bit Blind 10
Data point name 11text1 Bit Blind 11
Data point name 12text1 Bit Blind 12
Data point name 13text1 Bit Blind 13
Data point name 14text1 Bit Blind 14
Data point name 15text1 Bit Blind 15
Data point name 16text1 Bit Blind 16
Data point name 17text1 Bit Blind 17
Data point name 18text1 Bit Blind 18
Data point name 19text1 Bit Blind 19
Data point name 20text1 Bit Blind 20
Value 1 (Display)listNo
Data point name 1text1 Bit Value Display 1
Data point name 2text1 Bit Value Display 2
Value 3 (Display)listNo
Data point name 3text1 Bit Value Display 3
Data point name 4text1 Bit Value Display 4
Value 5 (Display)listNo
Data point name 5text1 Bit Value Display 5
Data point name 6text1 Bit Value Display 6
Value 7 (Display)listNo
Data point name 7text1 Bit Value Display 7
Data point name 8text1 Bit Value Display 8
Value 9 (Display)listNo
Data point name 9text1 Bit Value Display 9
Data point name 10text1 Bit Value Display 10
Value 11 (Display)listNo
Data point name 11text1 Bit Value Display 11
Data point name 12text1 Bit Value Display 12
Value 13 (Display)listNo
Data point name 13text1 Bit Value Display 13
Data point name 14text1 Bit Value Display 14
Value 15 (Display)listNo
Data point name 15text1 Bit Value Display 15
Data point name 16text1 Bit Value Display 16
Value 17 (Display)listNo
Data point name 17text1 Bit Value Display 17
Data point name 18text1 Bit Value Display 18
Value 19 (Display)listNo
Data point name 19text1 Bit Value Display 19
Data point name 20text1 Bit Value Display 20
Data point typelist2.001 Off/On controlled
Data point name 1text2 Bit Switch controlled 1
Data point name 2text2 Bit Switch controlled 2
Data point name 3text2 Bit Switch controlled 3
Data point name 4text2 Bit Switch controlled 4
Data point name 5text2 Bit Switch controlled 5
Data point typelist5.001 Percentage (0..100 %)
Data point name 1text1 Byte Value Display 1
Data point name 2text1 Byte Value Display 2
Data point name 3text1 Byte Value Display 3
Data point name 4text1 Byte Value Display 4
Data point name 5text1 Byte Value Display 5
Data point name 6text1 Byte Value Display 6
Data point name 7text1 Byte Value Display 7
Data point name 8text1 Byte Value Display 8
Data point name 9text1 Byte Value Display 9
Data point name 10text1 Byte Value Display 10
Data point name 11text1 Byte Value Display 11
Data point name 12text1 Byte Value Display 12
Data point name 13text1 Byte Value Display 13
Data point name 14text1 Byte Value Display 14
Data point name 15text1 Byte Value Display 15
Data point name 16text1 Byte Value Display 16
Data point name 17text1 Byte Value Display 17
Data point name 18text1 Byte Value Display 18
Data point name 19text1 Byte Value Display 19
Data point name 20text1 Byte Value Display 20
Value 1 (Change+Display)listNo
Data point name 1text1 Byte Value Change+Display 1
Value 2 (Change+Display)listNo
Data point name 2text1 Byte Value Change+Display 2
Value 3 (Change+Display)listNo
Data point name 3text1 Byte Value Change+Display 3
Value 4 (Change+Display)listNo
Data point name 4text1 Byte Value Change+Display 4
Value 5 (Change+Display)listNo
Data point name 5text1 Byte Value Change+Display 5
Value 6 (Change+Display)listNo
Data point name 6text1 Byte Value Change+Display 6
Value 7 (Change+Display)listNo
Data point name 7text1 Byte Value Change+Display 7
Value 8 (Change+Display)listNo
Data point name 8text1 Byte Value Change+Display 8
Value 9 (Change+Display)listNo
Data point name 9text1 Byte Value Change+Display 9
Value 10 (Change+Display)listNo
Data point name 10text1 Byte Value Change+Display 10
Value 11 (Change+Display)listNo
Data point name 11text1 Byte Value Change+Display 11
Value 12 (Change+Display)listNo
Data point name 12text1 Byte Value Change+Display 12
Value 13 (Change+Display)listNo
Data point name 13text1 Byte Value Change+Display 13
Value 14 (Change+Display)listNo
Data point name 14text1 Byte Value Change+Display 14
Value 15 (Change+Display)listNo
Data point name 15text1 Byte Value Change+Display 15
Value 16 (Change+Display)listNo
Data point name 16text1 Byte Value Change+Display 16
Value 17 (Change+Display)listNo
Data point name 17text1 Byte Value Change+Display 17
Value 18 (Change+Display)listNo
Data point name 18text1 Byte Value Change+Display 18
Value 19 (Change+Display)listNo
Data point name 19text1 Byte Value Change+Display 19
Value 20 (Change+Display)listNo
Data point name 20text1 Byte Value Change+Display 20
Data point typelist18.001 Scene Control
Data point name 1text1 Byte Scene 1
Scene Numberlist1
Data point name 2text1 Byte Scene 2
Data point name 3text1 Byte Scene 3
Data point name 4text1 Byte Scene 4
Data point name 5text1 Byte Scene 5
Data point typelist7.001 Value (0..65535)
Data point name 1text2 Byte Value Display 1
Data point name 2text2 Byte Value Display 2
Data point name 3text2 Byte Value Display 3
Data point name 4text2 Byte Value Display 4
Data point name 5text2 Byte Value Display 5
Data point name 6text2 Byte Value Display 6
Data point name 7text2 Byte Value Display 7
Data point name 8text2 Byte Value Display 8
Data point name 9text2 Byte Value Display 9
Data point name 10text2 Byte Value Display 10
Data point name 11text2 Byte Value Display 11
Data point name 12text2 Byte Value Display 12
Data point name 13text2 Byte Value Display 13
Data point name 14text2 Byte Value Display 14
Data point name 15text2 Byte Value Display 15
Data point name 16text2 Byte Value Display 16
Data point name 17text2 Byte Value Display 17
Data point name 18text2 Byte Value Display 18
Data point name 19text2 Byte Value Display 19
Data point name 20text2 Byte Value Display 20
Data point name 1text2 Byte Value Change+Display 1
Data point name 2text2 Byte Value Change+Display 2
Data point name 3text2 Byte Value Change+Display 3
Data point name 4text2 Byte Value Change+Display 4
Data point name 5text2 Byte Value Change+Display 5
Data point name 6text2 Byte Value Change+Display 6
Data point name 7text2 Byte Value Change+Display 7
Data point name 8text2 Byte Value Change+Display 8
Data point name 9text2 Byte Value Change+Display 9
Data point name 10text2 Byte Value Change+Display 10
Data point name 11text2 Byte Value Change+Display 11
Data point name 12text2 Byte Value Change+Display 12
Data point name 13text2 Byte Value Change+Display 13
Data point name 14text2 Byte Value Change+Display 14
Data point name 15text2 Byte Value Change+Display 15
Data point name 16text2 Byte Value Change+Display 16
Data point name 17text2 Byte Value Change+Display 17
Data point name 18text2 Byte Value Change+Display 18
Data point name 19text2 Byte Value Change+Display 19
Data point name 20text2 Byte Value Change+Display 20
Data point typelist12.001 Value (unsigned)
Data point name 1text4 Byte Value Display 1
Metering mediumlist---
Identification numberunsignedInt 0…999999990
Data point name 2text4 Byte Value Display 2
Data point name 3text4 Byte Value Display 3
Data point name 4text4 Byte Value Display 4
Data point name 5text4 Byte Value Display 5
Data point name 6text4 Byte Value Display 6
Data point name 7text4 Byte Value Display 7
Data point name 8text4 Byte Value Display 8
Data point name 9text4 Byte Value Display 9
Data point name 10text4 Byte Value Display 10
Data point name 11text4 Byte Value Display 11
Data point name 12text4 Byte Value Display 12
Data point name 13text4 Byte Value Display 13
Data point name 14text4 Byte Value Display 14
Data point name 15text4 Byte Value Display 15
Data point name 16text4 Byte Value Display 16
Data point name 17text4 Byte Value Display 17
Data point name 18text4 Byte Value Display 18
Data point name 19text4 Byte Value Display 19
Data point name 20text4 Byte Value Display 20
Value 21 (Display)listNo
Data point name 21text4 Byte Value Display 21
Data point name 22text4 Byte Value Display 22
Value 23 (Display)listNo
Data point name 23text4 Byte Value Display 23
Data point name 24text4 Byte Value Display 24
Value 25 (Display)listNo
Data point name 25text4 Byte Value Display 25
Data point name 26text4 Byte Value Display 26
Value 27 (Display)listNo
Data point name 27text4 Byte Value Display 27
Data point name 28text4 Byte Value Display 28
Value 29 (Display)listNo
Data point name 29text4 Byte Value Display 29
Data point name 30text4 Byte Value Display 30
Value 31 (Display)listNo
Data point name 31text4 Byte Value Display 31
Data point name 32text4 Byte Value Display 32
Value 33 (Display)listNo
Data point name 33text4 Byte Value Display 33
Data point name 34text4 Byte Value Display 34
Value 35 (Display)listNo
Data point name 35text4 Byte Value Display 35
Data point name 36text4 Byte Value Display 36
Value 37 (Display)listNo
Data point name 37text4 Byte Value Display 37
Data point name 38text4 Byte Value Display 38
Value 39 (Display)listNo
Data point name 39text4 Byte Value Display 39
Data point name 40text4 Byte Value Display 40
GrpObjTbl[1]_DPTunsignedInt 0…42949672950
GrpObjRef[1]_ObjTypeunsignedInt 0…655351001
GrpObjRef[1]_ObjInstunsignedInt 0…2551
GrpObjRef[1]_PropIDunsignedInt 0…25551
GrpObjRef[1]_StartIdxunsignedInt 0…655351
GrpObjRef[1]_BitOffsetunsignedInt 0…2550
GrpObjRef[1]_ConversionunsignedInt 0…255208
GrpObjTbl[2]_DPTunsignedInt 0…42949672950
GrpObjRef[2]_ObjTypeunsignedInt 0…655351001
GrpObjRef[2]_ObjInstunsignedInt 0…2551
GrpObjRef[2]_PropIDunsignedInt 0…255253
GrpObjRef[2]_StartIdxunsignedInt 0…655351
GrpObjRef[2]_BitOffsetunsignedInt 0…2550
GrpObjRef[2]_ConversionunsignedInt 0…255203
GrpObjTbl[3]_DPTunsignedInt 0…42949672950
GrpObjRef[3]_ObjTypeunsignedInt 0…655351001
GrpObjRef[3]_ObjInstunsignedInt 0…2551
GrpObjRef[3]_PropIDunsignedInt 0…255252
GrpObjRef[3]_StartIdxunsignedInt 0…655351
GrpObjRef[3]_BitOffsetunsignedInt 0…2550
GrpObjRef[3]_ConversionunsignedInt 0…255203
GrpObjTbl[4]_DPTunsignedInt 0…42949672950
GrpObjRef[4]_ObjTypeunsignedInt 0…655351002
GrpObjRef[4]_ObjInstunsignedInt 0…2551
GrpObjRef[4]_PropIDunsignedInt 0…25551
GrpObjRef[4]_StartIdxunsignedInt 0…655351
GrpObjRef[4]_BitOffsetunsignedInt 0…2550
GrpObjRef[4]_ConversionunsignedInt 0…255206
GrpObjTbl[5]_DPTunsignedInt 0…42949672950
GrpObjRef[5]_ObjTypeunsignedInt 0…655351002
GrpObjRef[5]_ObjInstunsignedInt 0…2551
GrpObjRef[5]_PropIDunsignedInt 0…25555
GrpObjRef[5]_StartIdxunsignedInt 0…655351
GrpObjRef[5]_BitOffsetunsignedInt 0…2557
GrpObjRef[5]_ConversionunsignedInt 0…255209
GrpObjTbl[6]_DPTunsignedInt 0…42949672950
GrpObjRef[6]_ObjTypeunsignedInt 0…655351002
GrpObjRef[6]_ObjInstunsignedInt 0…2551
GrpObjRef[6]_PropIDunsignedInt 0…25557
GrpObjRef[6]_StartIdxunsignedInt 0…655351
GrpObjRef[6]_BitOffsetunsignedInt 0…2557
GrpObjRef[6]_ConversionunsignedInt 0…255209
GrpObjTbl[7]_DPTunsignedInt 0…42949672950
GrpObjRef[7]_ObjTypeunsignedInt 0…655351002
GrpObjRef[7]_ObjInstunsignedInt 0…2551
GrpObjRef[7]_PropIDunsignedInt 0…25553
GrpObjRef[7]_StartIdxunsignedInt 0…655351
GrpObjRef[7]_BitOffsetunsignedInt 0…2557
GrpObjRef[7]_ConversionunsignedInt 0…255209
GrpObjTbl[8]_DPTunsignedInt 0…42949672950
GrpObjRef[8]_ObjTypeunsignedInt 0…6553550200
GrpObjRef[8]_ObjInstunsignedInt 0…2551
GrpObjRef[8]_PropIDunsignedInt 0…255240
GrpObjRef[8]_StartIdxunsignedInt 0…655351
GrpObjRef[8]_BitOffsetunsignedInt 0…2557
GrpObjRef[8]_ConversionunsignedInt 0…255209
GrpObjTbl[9]_DPTunsignedInt 0…42949672950
GrpObjRef[9]_ObjTypeunsignedInt 0…6553550200
GrpObjRef[9]_ObjInstunsignedInt 0…2551
GrpObjRef[9]_PropIDunsignedInt 0…255240
GrpObjRef[9]_StartIdxunsignedInt 0…655352
GrpObjRef[9]_BitOffsetunsignedInt 0…2557
GrpObjRef[9]_ConversionunsignedInt 0…255209
GrpObjTbl[10]_DPTunsignedInt 0…42949672950
GrpObjRef[10]_ObjTypeunsignedInt 0…6553550200
GrpObjRef[10]_ObjInstunsignedInt 0…2551
GrpObjRef[10]_PropIDunsignedInt 0…255240
GrpObjRef[10]_StartIdxunsignedInt 0…655353
GrpObjRef[10]_BitOffsetunsignedInt 0…2557
GrpObjRef[10]_ConversionunsignedInt 0…255209
GrpObjTbl[11]_DPTunsignedInt 0…42949672950
GrpObjRef[11]_ObjTypeunsignedInt 0…6553550200
GrpObjRef[11]_ObjInstunsignedInt 0…2551
GrpObjRef[11]_PropIDunsignedInt 0…255240
GrpObjRef[11]_StartIdxunsignedInt 0…655354
GrpObjRef[11]_BitOffsetunsignedInt 0…2557
GrpObjRef[11]_ConversionunsignedInt 0…255209
GrpObjTbl[12]_DPTunsignedInt 0…42949672950
GrpObjRef[12]_ObjTypeunsignedInt 0…6553550200
GrpObjRef[12]_ObjInstunsignedInt 0…2551
GrpObjRef[12]_PropIDunsignedInt 0…255240
GrpObjRef[12]_StartIdxunsignedInt 0…655355
GrpObjRef[12]_BitOffsetunsignedInt 0…2557
GrpObjRef[12]_ConversionunsignedInt 0…255209
GrpObjTbl[13]_DPTunsignedInt 0…42949672950
GrpObjRef[13]_ObjTypeunsignedInt 0…6553550200
GrpObjRef[13]_ObjInstunsignedInt 0…2551
GrpObjRef[13]_PropIDunsignedInt 0…255240
GrpObjRef[13]_StartIdxunsignedInt 0…655356
GrpObjRef[13]_BitOffsetunsignedInt 0…2557
GrpObjRef[13]_ConversionunsignedInt 0…255209
GrpObjTbl[14]_DPTunsignedInt 0…42949672950
GrpObjRef[14]_ObjTypeunsignedInt 0…6553550200
GrpObjRef[14]_ObjInstunsignedInt 0…2551
GrpObjRef[14]_PropIDunsignedInt 0…255240
GrpObjRef[14]_StartIdxunsignedInt 0…655357
GrpObjRef[14]_BitOffsetunsignedInt 0…2557
GrpObjRef[14]_ConversionunsignedInt 0…255209
GrpObjTbl[15]_DPTunsignedInt 0…42949672950
GrpObjRef[15]_ObjTypeunsignedInt 0…6553550200
GrpObjRef[15]_ObjInstunsignedInt 0…2551
GrpObjRef[15]_PropIDunsignedInt 0…255240
GrpObjRef[15]_StartIdxunsignedInt 0…655358
GrpObjRef[15]_BitOffsetunsignedInt 0…2557
GrpObjRef[15]_ConversionunsignedInt 0…255209
GrpObjTbl[16]_DPTunsignedInt 0…42949672950
GrpObjRef[16]_ObjTypeunsignedInt 0…6553550200
GrpObjRef[16]_ObjInstunsignedInt 0…2551
GrpObjRef[16]_PropIDunsignedInt 0…255240
GrpObjRef[16]_StartIdxunsignedInt 0…655359
GrpObjRef[16]_BitOffsetunsignedInt 0…2557
GrpObjRef[16]_ConversionunsignedInt 0…255209
GrpObjTbl[17]_DPTunsignedInt 0…42949672950
GrpObjRef[17]_ObjTypeunsignedInt 0…6553550200
GrpObjRef[17]_ObjInstunsignedInt 0…2551
GrpObjRef[17]_PropIDunsignedInt 0…255240
GrpObjRef[17]_StartIdxunsignedInt 0…6553510
GrpObjRef[17]_BitOffsetunsignedInt 0…2557
GrpObjRef[17]_ConversionunsignedInt 0…255209
GrpObjTbl[18]_DPTunsignedInt 0…42949672950
GrpObjRef[18]_ObjTypeunsignedInt 0…6553550200
GrpObjRef[18]_ObjInstunsignedInt 0…2551
GrpObjRef[18]_PropIDunsignedInt 0…255240
GrpObjRef[18]_StartIdxunsignedInt 0…6553511
GrpObjRef[18]_BitOffsetunsignedInt 0…2557
GrpObjRef[18]_ConversionunsignedInt 0…255209
GrpObjTbl[19]_DPTunsignedInt 0…42949672950
GrpObjRef[19]_ObjTypeunsignedInt 0…6553550200
GrpObjRef[19]_ObjInstunsignedInt 0…2551
GrpObjRef[19]_PropIDunsignedInt 0…255240
GrpObjRef[19]_StartIdxunsignedInt 0…6553512
GrpObjRef[19]_BitOffsetunsignedInt 0…2557
GrpObjRef[19]_ConversionunsignedInt 0…255209
GrpObjTbl[20]_DPTunsignedInt 0…42949672950
GrpObjRef[20]_ObjTypeunsignedInt 0…6553550200
GrpObjRef[20]_ObjInstunsignedInt 0…2551
GrpObjRef[20]_PropIDunsignedInt 0…255240
GrpObjRef[20]_StartIdxunsignedInt 0…6553513
GrpObjRef[20]_BitOffsetunsignedInt 0…2557
GrpObjRef[20]_ConversionunsignedInt 0…255209
GrpObjTbl[21]_DPTunsignedInt 0…42949672950
GrpObjRef[21]_ObjTypeunsignedInt 0…6553550200
GrpObjRef[21]_ObjInstunsignedInt 0…2551
GrpObjRef[21]_PropIDunsignedInt 0…255240
GrpObjRef[21]_StartIdxunsignedInt 0…6553514
GrpObjRef[21]_BitOffsetunsignedInt 0…2557
GrpObjRef[21]_ConversionunsignedInt 0…255209
GrpObjTbl[22]_DPTunsignedInt 0…42949672950
GrpObjRef[22]_ObjTypeunsignedInt 0…6553550200
GrpObjRef[22]_ObjInstunsignedInt 0…2551
GrpObjRef[22]_PropIDunsignedInt 0…255240
GrpObjRef[22]_StartIdxunsignedInt 0…6553515
GrpObjRef[22]_BitOffsetunsignedInt 0…2557
GrpObjRef[22]_ConversionunsignedInt 0…255209
GrpObjTbl[23]_DPTunsignedInt 0…42949672950
GrpObjRef[23]_ObjTypeunsignedInt 0…6553550200
GrpObjRef[23]_ObjInstunsignedInt 0…2551
GrpObjRef[23]_PropIDunsignedInt 0…255240
GrpObjRef[23]_StartIdxunsignedInt 0…6553516

First 500 of 2000 parameters shown. Download the .knxprod for the full list.

Version history

ApplicationApp noFingerprintFirst seenSizeFile
OZW772 Web-Server 2.0 latest$C00478872026-11-25254 KBDownload

About this file

This is the official ETS product database for the Siemens HVAC OZW772.16 Web Server (OZW772.16), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.

More from Siemens HVAC

All Siemens HVAC products