Analogue actuator REG-K/4-gang MTN682291
Schneider Electric Industries SAS · Order number MTN682291 · 4.9 Analogue Actuator › 4.9.01 DIN rail mounted REG-K
MTN682291
Download .knxprod Analogue output floating point/value B008/1.2 1.2 · 126 KB
Product
| Manufacturer | Schneider Electric Industries SAS |
|---|---|
| Product name | Analogue actuator REG-K/4-gang |
| Order number | MTN682291 |
| Hardware | Analogaktor REG-K/4fach |
| Medium | Twisted Pair |
| Rail mounted | Yes |
| Registration | Certified |
| Languages | en-US, de-DE, fr-FR, da-DK, nl-NL, it-IT, sv-SE, es-ES |
| Catalog entry | M-0064_H-MTN682291-1-O00F4_HP-B008-12-312E-O00F4_CI-MTN682291-1 |
| Fingerprint | 312E |
| SHA-256 | f47c3d850035bcf22d1a0f98ec9d69ebad6f722781f41e50f6f774aa7313743f |
| First seen | 2026-11-25 |
| Markets | 59 markets |
Application program: Analogue output floating point/value B008/1.2 1.2
| Application number | $B008 |
|---|---|
| Version | 1.2 |
| Mask version | MV-0701 (7.1) |
| KNX Data Secure | No |
| Parameters | 434 |
| Group objects | 74 |
Group objects (74)
| No | Name | Function | Size | DPT | Flags |
|---|---|---|---|---|---|
| 0 | Input value, output 1 | Analogue output | 1 Byte | CWU | |
| 0 | Input value, output 1 | Analogue output | 2 Bytes | CWU | |
| 1 | Input value, output 2 | Analogue output | 1 Byte | CWU | |
| 1 | Input value, output 2 | Analogue output | 2 Bytes | CWU | |
| 2 | Input value, output 3 | Analogue output | 2 Bytes | CWU | |
| 2 | Input value, output 3 | Analogue output | 1 Byte | CWU | |
| 3 | Input value, output 4 | Analogue output | 2 Bytes | CWU | |
| 3 | Input value, output 4 | Analogue output | 1 Byte | CWU | |
| 4 | Status output 1 | Analogue output | 2 Bytes | CRTU | |
| 4 | Status output 1 | Analogue output | 1 Byte | CRTU | |
| 5 | Status output 2 | Analogue output | 2 Bytes | CRTU | |
| 5 | Status output 2 | Analogue output | 1 Byte | CRTU | |
| 6 | Status output 3 | Analogue output | 2 Bytes | CRTU | |
| 6 | Status output 3 | Analogue output | 1 Byte | CRTU | |
| 7 | Status output 4 | Analogue output | 2 Bytes | CRTU | |
| 7 | Status output 4 | Analogue output | 1 Byte | CRTU | |
| 8 | Priority control 1, output 1 | Analogue output | 1 Bit | CWU | |
| 9 | Priority control 2, output 1 | Analogue output | 1 Bit | CWU | |
| 10 | Priority control 1, output 2 | Analogue output | 1 Bit | CWU | |
| 11 | Priority control 2, output 2 | Analogue output | 1 Bit | CWU | |
| 12 | Priority control 1, output 3 | Analogue output | 1 Bit | CWU | |
| 13 | Priority control 2, output 3 | Analogue output | 1 Bit | CWU | |
| 14 | Priority control 1, output 4 | Analogue output | 1 Bit | CWU | |
| 15 | Priority control 2, output 4 | Analogue output | 1 Bit | CWU | |
| 16 | Switch output 1 | Analogue output | 1 Bit | CWU | |
| 17 | Switch output 2 | Analogue output | 1 Bit | CWU | |
| 18 | Switch output 3 | Analogue output | 1 Bit | CWU | |
| 19 | Switch output 4 | Analogue output | 1 Bit | CWU | |
| 20 | Dimming output 1 | Analogue output | 4 Bit | CWU | |
| 21 | Dimming output 2 | Analogue output | 4 Bit | CWU | |
| 22 | Dimming output 3 | Analogue output | 4 Bit | CWU | |
| 23 | Dimming output 4 | Analogue output | 4 Bit | CWU | |
| 24 | Alarm output 1 | Analogue output | 1 Bit | CTU | |
| 25 | Alarm output 2 | Analogue output | 1 Bit | CTU | |
| 26 | Alarm output 3 | Analogue output | 1 Bit | CTU | |
| 27 | Alarm output 4 | Analogue output | 1 Bit | CTU | |
| 28 | Alarm | Analogue output | 1 Bit | CU | |
| 29 | Input value, output 5 | Extension module | 2 Bytes | CWU | |
| 29 | Input value, output 5 | Extension module | 1 Byte | CWU | |
| 30 | Input value, output 6 | Extension module | 2 Bytes | CWU | |
| 30 | Input value, output 6 | Extension module | 1 Byte | CWU | |
| 31 | Input value, output 7 | Extension module | 2 Bytes | CWU | |
| 31 | Input value, output 7 | Extension module | 1 Byte | CWU | |
| 32 | Input value, output 8 | Extension module | 2 Bytes | CWU | |
| 32 | Input value, output 8 | Extension module | 1 Byte | CWU | |
| 33 | Status output 5 | Extension module | 2 Bytes | CRTU | |
| 33 | Status output 5 | Extension module | 1 Byte | CRTU | |
| 34 | Status output 6 | Extension module | 2 Bytes | CRTU | |
| 34 | Status output 6 | Extension module | 1 Byte | CRTU | |
| 35 | Status output 7 | Extension module | 2 Bytes | CRTU | |
| 35 | Status output 7 | Extension module | 1 Byte | CRTU | |
| 36 | Status output 8 | Extension module | 2 Bytes | CRTU | |
| 36 | Status output 8 | Extension module | 1 Byte | CRTU | |
| 37 | Priority control 1, output 5 | Extension module | 1 Bit | CWU | |
| 38 | Priority control 2, output 5 | Extension module | 1 Bit | CWU | |
| 39 | Priority control 1, output 6 | Extension module | 1 Bit | CWU | |
| 40 | Priority control 2, output 6 | Extension module | 1 Bit | CWU | |
| 41 | Priority control 1, output 7 | Extension module | 1 Bit | CWU | |
| 42 | Priority control 2, output 7 | Extension module | 1 Bit | CWU | |
| 43 | Priority control 1, output 8 | Extension module | 1 Bit | CWU | |
| 44 | Priority control 2, output 8 | Extension module | 1 Bit | CWU | |
| 45 | Switch output 5 | Extension module | 1 Bit | CWU | |
| 46 | Switch output 6 | Extension module | 1 Bit | CWU | |
| 47 | Switch output 7 | Extension module | 1 Bit | CWU | |
| 48 | Switch output 8 | Extension module | 1 Bit | CWU | |
| 49 | Dimming output 5 | Extension module | 4 Bit | CWU | |
| 50 | Dimming output 6 | Extension module | 4 Bit | CWU | |
| 51 | Dimming output 7 | Extension module | 4 Bit | CWU | |
| 52 | Dimming output 8 | Extension module | 4 Bit | CWU | |
| 53 | Alarm output 5 | Extension module | 1 Bit | CTU | |
| 54 | Alarm output 6 | Extension module | 1 Bit | CTU | |
| 55 | Alarm output 7 | Extension module | 1 Bit | CTU | |
| 56 | Alarm output 8 | Extension module | 1 Bit | CTU | |
| 57 | Alarm | Extension module | 1 Bit | CTU |
Parameters (31)
| Parameter | Type | Default |
|---|---|---|
| General parameters | list | no |
| Signal output 1 | list | no function |
| Signal output 2 | list | no function |
| Signal output 3 | list | no function |
| Signal output 4 | list | no function |
| Extension module available | list | no |
| Signal output 5 | list | no function |
| Signal output 6 | list | no function |
| Signal output 7 | list | no function |
| Signal output 8 | list | no function |
| Input format | list | 16 bit |
| Input value for 0% output value (-32768...32767) | signedInt -32768…32767 | 0 |
| Input value for 0% output value | signedInt 0…255 | 0 |
| Input value for 100% output value (-32768...32767) | signedInt -32768…32767 | 1000 |
| Input value for 100% output value | signedInt 0…255 | 255 |
| Factor of input value | list | Input value * 0.01 |
| Output value after initialisation in % (0...100) | unsignedInt 0…100 | 0 |
| Behaviour when bus voltage fails | list | last value |
| Output value in % (0...100) | unsignedInt 0…100 | 0 |
| Behaviour when bus voltage recovers | list | no reaction |
| Scan input object at restart | list | no |
| Priority control object 1 | list | not available |
| Output value for priority 1 in % (0...100) | unsignedInt 0…100 | 50 |
| Priority control object 2 | list | not available |
| Output value for priority 2 in % (0...100) | unsignedInt 0…100 | 50 |
| Cyclical monitoring | list | no monitoring |
| Time factor for cyclical monitoring (1...255, base = 10s) | unsignedInt 1…255 | 6 |
| Output value for exceeding monitoring period in % (0...100) | unsignedInt 0…100 | 0 |
| Base for interval between 2 of 255 dimming levels | list | 10 ms |
| Time between 2 of 255 dimming levels (Factor 1...255) | unsignedInt 1…255 | 2 |
| Behaviour on receipt of a value | list | jump to value |
Version history
| Application | App no | Fingerprint | First seen | Size | File |
|---|---|---|---|---|---|
| Analogue output floating point/value B008/1.2 1.2 latest | $B008 | 312E | 2026-11-25 | 126 KB | Download |
About this file
This is the official ETS product database for the Schneider Electric Industries SAS Analogue actuator REG-K/4-gang (MTN682291), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.
More from Schneider Electric Industries SAS
- KNX FUGA Multif. push-button, display, RTCU, PI 507Dx042
- KNX FUGA Movement detector 180 507Dx350
- KNX FUGA Push-button 4 switch + LED 507Dx611
- KNX OPUS Multif. push-button, display, RTCU, PI 507Nx042
- KNX OPUS Movement detector 180 507Nx350
- KNX OPUS Push-button 4 switch + LED 507Nx611
- KNX Presence 507Z6352
- KNX Presence Basic 507Z6353
- KNX Presence with light control + IR 507Z6354
- KNX Push-button, 1-gang ALB4x150
- KNX Push-button, 2-gang ALB4x151
- KNX 1-gang push-button with IR receiver ALB4x152