Schneider Electric Industries SAS MTN6700-0104 Hybrid Switch Actuator REG-K/4x250/10 manual mode

Hybrid Switch Actuator REG-K/4x250/10 manual mode MTN6700-0104

Schneider Electric Industries SAS · Order number MTN6700-0104 · 4.4.0 Switch Actuator, 4-gang › 4.4.0.1 DIN rail mounted REG-K

Download .knxprod Switch/Curtain/Heating/Cooling 8140/1.2 1.2 · 178 KB

Product

ManufacturerSchneider Electric Industries SAS
Product nameHybrid Switch Actuator REG-K/4x250/10 manual mode
Order numberMTN6700-0104
HardwareHybrid Switch Actuator REG-K/4x250
MediumTwisted Pair
Bus current (mA)9
Rail mountedYes
Width (mm)72
RegistrationCertified · 2023-09-15
Languagesen-US
Catalog entryM-0064_H-Hybrid.20Switch.20Actuator.20REG.2DK.2F4x250.2F10.20manual.20mode-16_HP-8140-12-16A4_CI-MTN6700.2D0104-1
Fingerprint16A4
SHA-256e7f7e5611d765d6b809e8c48e24f7aab86ac8c4be5dabdb895a975986924dc7e
First seen2026-11-25
Markets59 markets

Application program: Switch/Curtain/Heating/Cooling 8140/1.2 1.2

Application number$8140
Version1.2
Mask versionMV-07B0 (System B)
KNX Data SecureNo
Minimum ETS version5.0
Parameters779
Group objects247
Group objects (247)
NoNameFunctionSizeDPTFlags
0Valve 1 {{0}}Heat/Cool mode status1 Bit1.100 cooling/heatingCRT
0Valve 2 {{0}}Heat/Cool mode status1 Bit1.100 cooling/heatingCRT
04-pipe Valve 1 {{0}}Heat/Cool mode status1 Bit1.100 cooling/heatingCRT
1GeneralLive signal1 Bit1.1 switchCT
1Valve 1 {{0}}Control value fault1 Bit1.5 alarmCRT
1Valve 2 {{0}}Control value fault1 Bit1.5 alarmCRT
14-pipe Valve 1 {{0}}Control value fault1 Bit1.5 alarmCRT
2Output 1: Switch {{0}}Switch1 Bit1.1 switchCW
2Output 1: Heating {{0}}On-off control value1 Bit1.1 switchCW
21 Blind {{0}}Move UP/DOWN1 Bit1.8 up/downCW
21 Roller shutter {{0}}Move UP/DOWN1 Bit1.8 up/downCW
2Valve 1 {{0}}Disable, Heat1 Bit1.3 enableCW
2Valve 1 {{0}}Disable, Heat/Cool1 Bit1.3 enableCW
2Valve 2 {{0}}Disable, Heat1 Bit1.3 enableCW
2Valve 2 {{0}}Disable, Heat/Cool1 Bit1.3 enableCW
24-pipe Valve 1 {{0}}Disable,Heat1 Bit1.3 enableCW
24-pipe Valve 1 {{0}}Disable,Heat/Cool1 Bit1.3 enableCW
3Output 1: Switch {{0}}Switch status1 Bit1.1 switchCRT
3Output 1: Heating {{0}}Status of contact1 Bit1.1 switchCRT
31 Blind {{0}}Slat adj/stop1 Bit1.7 stepCW
31 Roller shutter {{0}}Stop1 Bit1.7 stepCW
3Valve 1 {{0}}Control value, Heat1 Byte5.1 percentage (0..100%)CW
3Valve 1 {{0}}Control value, Heat1 Bit1.1 switchCW
3Valve 1 {{0}}Control value, Heat/Cool1 Bit1.1 switchCW
3Valve 1 {{0}}Control value, Heat/Cool1 Byte5.1 percentage (0..100%)CW
3Valve 2 {{0}}Control value, Heat1 Byte5.1 percentage (0..100%)CW
3Valve 2 {{0}}Control value, Heat1 Bit1.1 switchCW
3Valve 2 {{0}}Control value, Heat/Cool1 Bit1.1 switchCW
3Valve 2 {{0}}Control value, Heat/Cool1 Byte5.1 percentage (0..100%)CW
34-pipe Valve 1 {{0}}Control value, Heat1 Byte5.1 percentage (0..100%)CW
34-pipe Valve 1 {{0}}Control value, Heat1 Bit1.1 switchCW
34-pipe Valve 1 {{0}}Control value, Heat/Cool1 Bit1.1 switchCW
34-pipe Valve 1 {{0}}Control value, Heat/Cool1 Byte5.1 percentage (0..100%)CW
4Output 1: Switch {{0}}Switch time function1 Bit1.3 enableCW
4Output 1: Heating {{0}}Status of continuous, 1bit1 Bit1.1 switchCRT
41 Blind {{0}}Reference movement1 Bit1.8 up/downCW
41 Roller shutter {{0}}Reference movement1 Bit1.8 up/downCW
4Valve 1 {{0}}Valve status, Heat1 Byte5.1 percentage (0..100%)CRT
4Valve 1 {{0}}Valve status, Heat1 Bit1.1 switchCRT
4Valve 1 {{0}}Valve status, Heat/Cool1 Bit1.1 switchCRT
4Valve 1 {{0}}Valve status, Heat/Cool1 Byte5.1 percentage (0..100%)CRT
4Valve 2 {{0}}Valve status, Heat1 Byte5.1 percentage (0..100%)CRT
4Valve 2 {{0}}Valve status, Heat1 Bit1.1 switchCRT
4Valve 2 {{0}}Valve status, Heat/Cool1 Bit1.1 switchCRT
4Valve 2 {{0}}Valve status, Heat/Cool1 Byte5.1 percentage (0..100%)CRT
44-pipe Valve 1 {{0}}Valve status, Heat1 Byte5.1 percentage (0..100%)CRT
44-pipe Valve 1 {{0}}Valve status, Heat1 Bit1.1 switchCRT
44-pipe Valve 1 {{0}}Valve status, Heat/Cool1 Bit1.1 switchCRT
44-pipe Valve 1 {{0}}Valve status, Heat/Cool1 Byte5.1 percentage (0..100%)CRT
5Output 1: Switch {{0}}Switch out with delay1 Bit1.1 switchCW
5Output 1: Switch {{0}}Output of staircase timer1 Bit1.1 switchCW
5Output 1: Switch {{0}}Switch out with flashing1 Bit1.1 switchCW
5Output 1: Heating {{0}}Control value(Continuous)1 Byte5.1 percentage (0..100%)CW
51 Blind {{0}}Move to position 0..100%1 Byte5.1 percentage (0..100%)CW
51 Roller shutter {{0}}Move to position 0..100%1 Byte5.1 percentage (0..100%)CW
5Valve 1 {{0}}Trigger valve purge, Heat1 Bit1.3 enableCW
5Valve 1 {{0}}Trigger valve purge, Heat/Cool1 Bit1.3 enableCW
5Valve 2 {{0}}Trigger valve purge, Heat1 Bit1.3 enableCW
5Valve 2 {{0}}Trigger valve purge, Heat/Cool1 Bit1.3 enableCW
54-pipe Valve 1 {{0}}Trigger valve purge, Heat1 Bit1.3 enableCW
54-pipe Valve 1 {{0}}Trigger valve purge, Heat/Cool1 Bit1.3 enableCW
6Output 1: Switch {{0}}Operation hours counter4 Bytes13.100 time lag (s)CRWTU
6Output 1: Switch {{0}}Operation hours counter2 Bytes7.7 time (h)CRWTU
6Output 1: Heating {{0}}Status of continuous, 1byte1 Byte5.1 percentage (0..100%)CRT
61 Blind {{0}}Slat position 0..100%1 Byte5.1 percentage (0..100%)CW
6Valve 1 {{0}}Valve purge status, Heat1 Bit1.3 enableCRT
6Valve 1 {{0}}Valve purge status, Heat/Cool1 Bit1.3 enableCRT
6Valve 2 {{0}}Valve purge status, Heat1 Bit1.3 enableCRT
6Valve 2 {{0}}Valve purge status, Heat/Cool1 Bit1.3 enableCRT
64-pipe Valve 1 {{0}}Valve purge status, Heat1 Bit1.3 enableCRT
64-pipe Valve 1 {{0}}Valve purge status, Heat/Cool1 Bit1.3 enableCRT
7Output 1: Switch {{0}}Scene1 Byte18.1 scene controlCW
7Output 1: Heating {{0}}Report fault1 Bit1.5 alarmCRT
71 Blind {{0}}Scene1 Byte18.1 scene controlCW
71 Roller shutter {{0}}Scene1 Byte18.1 scene controlCW
7Valve 1 {{0}}Disable, Cool1 Bit1.3 enableCW
7Valve 2 {{0}}Disable, Cool1 Bit1.3 enableCW
74-pipe Valve 1 {{0}}Disable,Cool1 Bit1.3 enableCW
8Output 1: Switch {{0}}Forced output1 Bit1.3 enableCW
8Output 1: Switch {{0}}Forced output2 Bit2.1 switch controlCW
8Output 1: Heating {{0}}Forced output1 Bit1.3 enableCW
81 Blind {{0}}Status Position 0..100%1 Byte5.1 percentage (0..100%)CRT
81 Roller shutter {{0}}Status Position 0..100%1 Byte5.1 percentage (0..100%)CRT
8Valve 1 {{0}}Control value, Cool1 Byte5.1 percentage (0..100%)CW
8Valve 1 {{0}}Control value, Cool1 Bit1.1 switchCW
8Valve 2 {{0}}Control value, Cool1 Byte5.1 percentage (0..100%)CW
8Valve 2 {{0}}Control value, Cool1 Bit1.1 switchCW
84-pipe Valve 1 {{0}}Control value, Cool1 Byte5.1 percentage (0..100%)CW
84-pipe Valve 1 {{0}}Control value, Cool1 Bit1.1 switchCW
9Output 1: Switch {{0}}Logic 11 Bit1.2 booleanCW
9Output 1: Heating {{0}}Locking 1 heating1 Bit1.3 enableCW
91 Blind {{0}}Slat status 0..100%1 Byte5.1 percentage (0..100%)CRT
9Valve 1 {{0}}Valve status, Cool1 Byte5.1 percentage (0..100%)CRT
9Valve 1 {{0}}Valve status, Cool1 Bit1.1 switchCRT
9Valve 2 {{0}}Valve status, Cool1 Byte5.1 percentage (0..100%)CRT
9Valve 2 {{0}}Valve status, Cool1 Bit1.1 switchCRT
94-pipe Valve 1 {{0}}Valve status, Cool1 Byte5.1 percentage (0..100%)CRT
94-pipe Valve 1 {{0}}Valve status, Cool1 Bit1.1 switchCRT
10Output 1: Switch {{0}}Logic 21 Bit1.2 booleanCW
10Output 1: Heating {{0}}Locking 2 heating1 Bit1.3 enableCW
101 Blind {{0}}Sun operation1 Bit1.1 switchCW
101 Roller shutter {{0}}Sun operation1 Bit1.1 switchCW
10Valve 1 {{0}}Trigger valve purge, Cool1 Bit1.3 enableCW
10Valve 2 {{0}}Trigger valve purge, Cool1 Bit1.3 enableCW
104-pipe Valve 1 {{0}}Trigger valve purge, Cool1 Bit1.3 enableCW
11Output 1: Switch {{0}}Warning of staircase1 Bit1.5 alarmCT
111 Blind {{0}}Enable auto.control1 Bit1.3 enableCW
111 Roller shutter {{0}}Enable auto.control1 Bit1.3 enableCW
11Valve 1 {{0}}Valve purge status, Cool1 Bit1.3 enableCRT
11Valve 2 {{0}}Valve purge status, Cool1 Bit1.3 enableCRT
114-pipe Valve 1 {{0}}Valve purge status, Cool1 Bit1.3 enableCRT
12Output 1: Switch {{0}}Duration of staircase2 Bytes7.5 time (s)CRW
121 Blind {{0}}Sun:blind position 0..100%1 Byte5.1 percentage (0..100%)CW
121 Roller shutter {{0}}Sun:shutter position 0..100%1 Byte5.1 percentage (0..100%)CW
13Output 1: Switch {{0}}Lock1 Bit1.3 enableCW
131 Blind {{0}}Sun:slat adj. 0...100%1 Byte5.1 percentage (0..100%)CW
141 Blind {{0}}Safety operation 11 Bit1.5 alarmCW
141 Roller shutter {{0}}Safety operation 11 Bit1.5 alarmCW
14Output 2: Switch {{0}}Switch1 Bit1.1 switchCW
14Output 2: Heating {{0}}On-off control value1 Bit1.1 switchCW
151 Blind {{0}}Safety operation 21 Bit1.5 alarmCW
151 Roller shutter {{0}}Safety operation 21 Bit1.5 alarmCW
15Output 2: Switch {{0}}Switch status1 Bit1.1 switchCRT
15Output 2: Heating {{0}}Status of contact1 Bit1.1 switchCRT
16Output 2: Switch {{0}}Switch time function1 Bit1.3 enableCW
16Output 2: Heating {{0}}Status of continuous, 1bit1 Bit1.1 switchCRT
171 Blind {{0}}Lock1 Bit1.3 enableCW
171 Roller shutter {{0}}Lock1 Bit1.3 enableCW
17Output 2: Switch {{0}}Switch out with delay1 Bit1.1 switchCW
17Output 2: Switch {{0}}Switch out with flashing1 Bit1.1 switchCW
17Output 2: Switch {{0}}Output of staircase timer1 Bit1.1 switchCW
17Output 2: Heating {{0}}Control value(Continuous)1 Byte5.1 percentage (0..100%)CW
18Output 2: Switch {{0}}Operation hours counter4 Bytes13.100 time lag (s)CRWTU
18Output 2: Switch {{0}}Operation hours counter2 Bytes7.7 time (h)CRWTU
18Output 2: Heating {{0}}Status of continuous, 1byte1 Byte5.1 percentage (0..100%)CRT
19Output 2: Switch {{0}}Scene1 Byte18.1 scene controlCW
19Output 2: Heating {{0}}Report fault1 Bit1.5 alarmCRT
20Output 2: Switch {{0}}Forced output1 Bit1.3 enableCW
20Output 2: Switch {{0}}Forced output2 Bit2.1 switch controlCW
20Output 2: Heating {{0}}Forced output1 Bit1.3 enableCW
21Output 2: Switch {{0}}Logic 11 Bit1.2 booleanCW
21Output 2: Heating {{0}}Locking 1 heating1 Bit1.3 enableCW
22Output 2: Switch {{0}}Logic 21 Bit1.2 booleanCW
22Output 2: Heating {{0}}Locking 2 heating1 Bit1.3 enableCW
23Output 2: Switch {{0}}Warning of staircase1 Bit1.5 alarmCT
24Output 2: Switch {{0}}Duration of staircase2 Bytes7.5 time (s)CRW
25Output 2: Switch {{0}}Lock1 Bit1.3 enableCW
26Output 3: Switch {{0}}Switch1 Bit1.1 switchCW
26Output 3: Heating {{0}}On-off control value1 Bit1.1 switchCW
262 Blind {{0}}Move UP/DOWN1 Bit1.8 up/downCW
262 Roller shutter {{0}}Move UP/DOWN1 Bit1.8 up/downCW
27Output 3: Switch {{0}}Switch status1 Bit1.1 switchCRT
27Output 3: Heating {{0}}Status of contact1 Bit1.1 switchCRT
272 Blind {{0}}Slat adj/stop1 Bit1.7 stepCW
272 Roller shutter {{0}}Stop1 Bit1.7 stepCW
28Output 3: Switch {{0}}Switch time function1 Bit1.3 enableCW
28Output 3: Heating {{0}}Status of continuous, 1bit1 Bit1.1 switchCRT
282 Blind {{0}}Reference movement1 Bit1.8 up/downCW
282 Roller shutter {{0}}Reference movement1 Bit1.8 up/downCW
29Output 3: Switch {{0}}Switch out with delay1 Bit1.1 switchCW
29Output 3: Switch {{0}}Switch out with flashing1 Bit1.1 switchCW
29Output 3: Switch {{0}}Output of staircase timer1 Bit1.1 switchCW
29Output 3: Heating {{0}}Control value(Continuous)1 Byte5.1 percentage (0..100%)CW
292 Blind {{0}}Move to position 0..100%1 Byte5.1 percentage (0..100%)CW
292 Roller shutter {{0}}Move to position 0..100%1 Byte5.1 percentage (0..100%)CW
30Output 3: Switch {{0}}Operation hours counter4 Bytes13.100 time lag (s)CRWTU
30Output 3: Switch {{0}}Operation hours counter2 Bytes7.7 time (h)CRWTU
30Output 3: Heating {{0}}Status of continuous, 1byte1 Byte5.1 percentage (0..100%)CRT
302 Blind {{0}}Slat position 0..100%1 Byte5.1 percentage (0..100%)CW
31Output 3: Switch {{0}}Scene1 Byte18.1 scene controlCW
31Output 3: Heating {{0}}Report fault1 Bit1.5 alarmCRT
312 Blind {{0}}Scene1 Byte18.1 scene controlCW
312 Roller shutter {{0}}Scene1 Byte18.1 scene controlCW
32Output 3: Switch {{0}}Forced output1 Bit1.3 enableCW
32Output 3: Switch {{0}}Forced output2 Bit2.1 switch controlCW
32Output 3: Heating {{0}}Forced output1 Bit1.3 enableCW
322 Blind {{0}}Status Position 0..100%1 Byte5.1 percentage (0..100%)CRT
322 Roller shutter {{0}}Status Position 0..100%1 Byte5.1 percentage (0..100%)CRT
33Output 3: Switch {{0}}Logic 11 Bit1.2 booleanCW
33Output 3: Heating {{0}}Locking 1 heating1 Bit1.3 enableCW
332 Blind {{0}}Slat status 0..100%1 Byte5.1 percentage (0..100%)CRT
34Output 3: Switch {{0}}Logic 21 Bit1.2 booleanCW
34Output 3: Heating {{0}}Locking 2 heating1 Bit1.3 enableCW
342 Blind {{0}}Sun operation1 Bit1.1 switchCW
342 Roller shutter {{0}}Sun operation1 Bit1.1 switchCW
35Output 3: Switch {{0}}Warning of staircase1 Bit1.5 alarmCT
352 Blind {{0}}Enable auto.control1 Bit1.3 enableCW
352 Roller shutter {{0}}Enable auto.control1 Bit1.3 enableCW
36Output 3: Switch {{0}}Duration of staircase2 Bytes7.5 time (s)CRW
362 Blind {{0}}Sun:blind position 0..100%1 Byte5.1 percentage (0..100%)CW
362 Roller shutter {{0}}Sun:shutter position 0..100%1 Byte5.1 percentage (0..100%)CW
37Output 3: Switch {{0}}Lock1 Bit1.3 enableCW
372 Blind {{0}}Sun:slat adj. 0...100%1 Byte5.1 percentage (0..100%)CW
38Output 4: Switch {{0}}Switch1 Bit1.1 switchCW
38Output 4: Heating {{0}}On-off control value1 Bit1.1 switchCW
382 Blind {{0}}Safety operation 11 Bit1.5 alarmCW
382 Roller shutter {{0}}Safety operation 11 Bit1.5 alarmCW
39Output 4: Switch {{0}}Switch status1 Bit1.1 switchCRT
39Output 4: Heating {{0}}Status of contact1 Bit1.1 switchCRT
392 Blind {{0}}Safety operation 21 Bit1.5 alarmCW
392 Roller shutter {{0}}Safety operation 21 Bit1.5 alarmCW
40Output 4: Switch {{0}}Switch time function1 Bit1.3 enableCW
40Output 4: Heating {{0}}Status of continuous, 1bit1 Bit1.1 switchCRT
41Output 4: Switch {{0}}Switch out with delay1 Bit1.1 switchCW
41Output 4: Switch {{0}}Switch out with flashing1 Bit1.1 switchCW
41Output 4: Switch {{0}}Output of staircase timer1 Bit1.1 switchCW
41Output 4: Heating {{0}}Control value(Continuous)1 Byte5.1 percentage (0..100%)CW
412 Blind {{0}}Lock1 Bit1.3 enableCW
412 Roller shutter {{0}}Lock1 Bit1.3 enableCW
42Output 4: Switch {{0}}Operation hours counter4 Bytes13.100 time lag (s)CRWTU
42Output 4: Switch {{0}}Operation hours counter2 Bytes7.7 time (h)CRWTU
42Output 4: Heating {{0}}Status of continuous, 1byte1 Byte5.1 percentage (0..100%)CRT
43Output 4: Switch {{0}}Scene1 Byte18.1 scene controlCW
43Output 4: Heating {{0}}Report fault1 Bit1.5 alarmCRT
44Output 4: Switch {{0}}Forced output1 Bit1.3 enableCW
44Output 4: Switch {{0}}Forced output2 Bit2.1 switch controlCW
44Output 4: Heating {{0}}Forced output1 Bit1.3 enableCW
45Output 4: Switch {{0}}Logic 11 Bit1.2 booleanCW
45Output 4: Heating {{0}}Locking 1 heating1 Bit1.3 enableCW
46Output 4: Switch {{0}}Logic 21 Bit1.2 booleanCW
46Output 4: Heating {{0}}Locking 2 heating1 Bit1.3 enableCW
47Output 4: Switch {{0}}Warning of staircase1 Bit1.5 alarmCT
48Output 4: Switch {{0}}Duration of staircase2 Bytes7.5 time (s)CRW
49Output 4: Switch {{0}}Lock1 Bit1.3 enableCW
291Fan 1 {{0}}Fan speed1 Byte5.1 percentage (0..100%)CW
291Fan 1 {{0}}Fan speed1 Bit1.1 switchCW
291Fan 1 {{0}}Fan speed1 Byte5.100 fan stage (0..255)CW
292Fan 1 {{0}}Fan speed 11 Bit1.1 switchCW
293Fan 1 {{0}}Fan speed 21 Bit1.1 switchCW
294Fan 1 {{0}}Fan speed 31 Bit1.1 switchCW
295Fan 1 {{0}}Status Fan ON/OFF1 Bit1.1 switchCRT
296Fan 1 {{0}}Status Fan speed1 Byte5.100 fan stage (0..255)CRT
296Fan 1 {{0}}Status Fan speed1 Byte5.1 percentage (0..100%)CRT
297Fan 1 {{0}}Status Fan speed 11 Bit1.1 switchCRT
298Fan 1 {{0}}Status Fan speed 21 Bit1.1 switchCRT
299Fan 1 {{0}}Status Fan speed 31 Bit1.1 switchCRT
300Fan 1 {{0}}Automatic function1 Bit1.3 enableCW
301Fan 1 {{0}}Status Automatic1 Bit1.3 enableCRT
302Fan 1 {{0}}Forced operation1 Bit1.3 enableCW
303Fan 1 {{0}}Control value 11 Byte5.1 percentage (0..100%)CW
303Fan 1 {{0}}Control value1 Byte5.1 percentage (0..100%)CW
304Fan 1 {{0}}Control value 21 Byte5.1 percentage (0..100%)CW
305Fan 1 {{0}}Switching control value 1/21 Bit1.1 switchCW
306Fan 1 {{0}}Control value fault1 Bit1.5 alarmCRT
604GeneralCentral control for Up/Down1 Bit1.8 up/downCW
605GeneralCentral control for Slat/Stop1 Bit1.7 stepCW
606GeneralCentral control for all of switch1 Bit1.1 switchCW
Parameters (311)
ParameterTypeDefault
Sending delay after bus voltage recovery (0...255)unsignedInt 0…2555
Cyclic sending live signal (1...65535s,0=inactive)unsignedInt 0…655351
Limit number of send telegramunsignedInt 0…10
Periodlist100ms
Max.number tele.within a period (1...255)unsignedInt 1…255100
Central control for switch functionunsignedInt 0…10
Central control for curtain functionunsignedInt 0…10
Manual operationunsignedInt 0…11
Manual to automatic bylistOnly long press
Delay time (10...6000)unsignedInt 10…600010
Product selectlist4-Fold
Output 1~4 config aslistSwitch/Curtain AC/Heating/Cooling/2-pipe
Output 1&2 functionlistDisable
Output 1listDisable
Curtain 1 output is fixed forlistOutput 1(Up/Open) & Output 2(Down/Close)
Valve 1 output is fixed for Output 1listOutput1&2,if 3point,open and close
Output 3&4 functionlistDisable
Curtain 2 output is fixed forlistOutput 3(Up/Open) & Output 4(Down/Close)
Valve 2 output is fixed for Output 3listOutput3&4,if 3point,open and close
Fan 1 output is fixed forlist1level:1; 2level:1&2; 3level: 1&2&3
If Fan 1 set to 1 or 2 level,output 3&4 as switch outputlist<<--Attention
Heat output for 4-pipe valve 1 is Output 1listOutput1&2,if 3point,open and close
Cool output for 4-pipe valve 1 is Output 3listOutput3&4,if 3point,open and close
Central functionunsignedInt 0…10
Relay state after bus voltage recoverylistUnchange
Relay state after bus voltage failurelistUnchange
Relay state after ETS downloadlistOpen
Object value of "switch" after bus recoverylist0
Status ResponselistRespond after change
Object value of switch statuslist1=contact close;0=contact open
Contact position if tele.value is "1" ("0" is opposite of "1" if changed)listClose
Valve typelistNormal (de-energised closed)
Valve position at bus voltage failurelistUnchange
Value position at bus voltage recoverylist0%[Closed]
PWM cycle time for continuous (60...65535)unsignedInt 60…65535120
Control telegram is received aslist1bit (on-off control or PWM)
Reply the status for continuous controllistNo reply
Reply the status for contactlistYes, 1=contact close; 0=contact open
Cyclic surveillanceunsignedInt 0…11
Cyclic surveillance of themostat (0...65535)unsignedInt 0…65535120
Valve position during faultlistUnchange
Send object "Report fault" isunsignedInt 0…11
Forced FunctionunsignedInt 0…10
Valve position during forced operationlistUnchange
TimeunsignedInt 0…10
Logic functionunsignedInt 0…10
SceneunsignedInt 0…10
Force operation typelist1Bit
Contact position if forced operationlistUnchange
Operation hours counterunsignedInt 0…10
Object datatype of "Operation hours counter"list4 byte Value in s(DPT13.100)
Cyclically send counter value in (0...100) (0 = not send,only for reading)unsignedInt 0…1000
Type of time functionlistDelay
Delay for switch on: --(0...240)unsignedInt 0…2400
--(0...59)unsignedInt 0…590
Delay for switch off: --(0...240)unsignedInt 0…2400
Time for switch on: --(0...240)unsignedInt 0…2400
Time for switch off: --(0...240)unsignedInt 0…2400
Number of ON-implused (1...255,0=no limited)unsignedInt 0…2550
Contact position after flashinglistUnchange
Control mode of flashinglistStart with "1",Stop with"0"
Duration of staircase timer: --(0...1000)unsignedInt 0…10001
Control mode of staircase timerlistStart with "1",Stop with"0"
Staircase timer islistNot retriggerable
Modify the duration via object (0...60059s)unsignedInt 0…10
Enable input 0unsignedInt 0…10
Input 0 reverselistNO
The input 1 of logicunsignedInt 0…10
Logic function typelistAND
Input 1 reverselistNO
Result reverselistNO
Value of input1 after bus recoverylist0
The input 2 of logicunsignedInt 0…10
Input 2 reverselistNO
Value of input2 after bus recoverylist0
Overwrite scene stored values during downloadunsignedInt 0…11
1> channel is assigned to (1...64,0=no assignment)unsignedInt 0…640
Standard output value islistOFF
2> channel is assigned to (1...64,0=no assignment)unsignedInt 0…640
3> channel is assigned to (1...64,0=no assignment)unsignedInt 0…640
4> channel is assigned to (1...64,0=no assignment)unsignedInt 0…640
5> channel is assigned to (1...64,0=no assignment)unsignedInt 0…640
6> channel is assigned to (1...64,0=no assignment)unsignedInt 0…640
7> channel is assigned to (1...64,0=no assignment)unsignedInt 0…640
8> channel is assigned to (1...64,0=no assignment)unsignedInt 0…640
Config channel function aslistBlind
Motor typelistAC-motor
After reference movement,Position islistDisable
Position of slat after arriving on lower end positionlist100
When blind is under end position,up/down object function islistDisable
Total travel time (20...50000)unsignedInt 20…50000600
Delay time from switch-on to moving (0...200)unsignedInt 0…2000
Duration of Slat adjustment (10...250)unsignedInt 10…25020
Total travel time of Slat 0-100 % in (10...250)unsignedInt 10…250100
Pause on change in direction (5...255)unsignedInt 5…25550
Additional travel time in upward direction (0...255)unsignedInt 0…2550
Auto functionunsignedInt 0…10
Object value of "Enable auto. control" after bus voltage recoverylist"0"(Disable auto. control)
Automatically enable for auto.controllistNO
Enable auto. control after (10...6000)unsignedInt 10…600010
Position if sun = 1 (sun is shining)listDown
Delay time on sun = 1 (0...65535)unsignedInt 0…6553510
Position if sun = 0 (sun not shining)listDown
Delay time on sun = 0 (0...65535)unsignedInt 0…6553510
1> Channel is assigned to (1...64,0=no assignment)unsignedInt 0…640
Blind position (0%=top,100%=bottom)unsignedInt 0…1000
Slat position (0%=open,100%=close)unsignedInt 0…1000
2> Channel is assigned to (1...64,0=no assignment)unsignedInt 0…640
3> Channel is assigned to (1...64,0=no assignment)unsignedInt 0…640
4> Channel is assigned to (1...64,0=no assignment)unsignedInt 0…640
5> Channel is assigned to (1...64,0=no assignment)unsignedInt 0…640
6> Channel is assigned to (1...64,0=no assignment)unsignedInt 0…640
7> Channel is assigned to (1...64,0=no assignment)unsignedInt 0…640
8> Channel is assigned to (1...64,0=no assignment)unsignedInt 0…640
Safety functionunsignedInt 0…10
Safety operation 1listInactive
Safety operation trigger value (Cancel safety is opposite of selection)list0
Position on safety operation 1listUnchange
Cyclic monitoring time in (0...65535,0=no monitoring)unsignedInt 0…65535120
Safety operation 2listInactive
Position on safety operation 2listUnchange
Position with canceling of the safety operationlistUnchange
Delay time from switch-off to Stop (0...200)unsignedInt 0…2000
Shutter position (0%=top,100% =bottom)unsignedInt 0…1000
Fan typelistMulti-level
Fan speed at bus voltage failurelistUnchange
Fan speed at bus voltage recoverylistUnchange
Fan speed at ETS downloadlistOFF
Forced functionunsignedInt 0…10
Forced operation on object valuelist1=Force/0=Cancel
Behaviour on Forced operationlistUnchange
Auto. FunctionunsignedInt 0…10
Time mode for function ONlistSwitch Delay
Delay time (1...65535)unsignedInt 1…6553510
Minimum time (1...65535)unsignedInt 1…6553510
Time mode for function OFFlistSwitch Delay
Fan speeds on 2 limitunsignedInt 0…10
Fan operation modelistChangover switch
Delay between fan speed switch (50...5000)unsignedInt 50…5000500
Object value for Fan speed 1unsignedInt 1…2551
Object value for Fan speed 2unsignedInt 1…2552
Object value for Fan speed 3unsignedInt 1…2553
Obj. "Switch speed x " 1bit functionunsignedInt 0…10
Delay time for function OFF (0...65535)unsignedInt 0…655350
Starting characteristicunsignedInt 0…11
Switch on over fan speedlist1
Minimum time in switch (1...65535)unsignedInt 1…6553510
Auto.operation on object valuelist1=Auto/0=Cancel
State of Auto.operation after startuplistDisable
Automatically enable auto.operationunsignedInt 0…10
Enable auto.operation after in (10...6000)unsignedInt 10…6000100
Threshold value 0FF<->ON[1..100]unsignedInt 1…10030
Hysteresis threshold value in +/-(0...50)unsignedInt 0…5010
Number of control valuelist1
Select bylistControl value with switching object
Monitoring control valueunsignedInt 0…11
Monitoring period of control value (10...65535)unsignedInt 10…65535120
Reply mode of Obj."Control value fault"listRespond after change
Control value after fault occurs (0...100)unsignedInt 0…1000
Reply mode of Obj. "Status Fan ON/OFF"(1bit)listRespond after change
Reply mode of Obj. "Status Automatic"(1bit)listRespond after change
Threshold value OFF<->speed 1 (1...100)unsignedInt 1…10030
Threshold value speed 1<->speed 2 (1...100)unsignedInt 1…10060
Threshold value speed 2<->speed 3 (1...100)unsignedInt 1…10080
Minimum time in fan speed (0...65535)unsignedInt 0…6553510
Reply mode of Obj. "Status Fan speed x"(1bit)listRespond after change
Reply mode of Obj. "Status Fan speed"(1byte)listRespond after change
Status value for Fan speed 1unsignedInt 1…2551
Status value for Fan speed 2unsignedInt 1…2552
Status value for Fan speed 3unsignedInt 1…2553
Description (max 30char.)text
Object datatype of 1byte fan speedlistPercentage (DPT_5.001)
Object value for Fan speed 3list100
Object value for Fan speed 2list67
Object value for Fan speed 1list33
Status value for Fan speed 1list33
Status value for Fan speed 2list67
Status value for Fan speed 3list100
Locking FunctionunsignedInt 0…10
ON delay islistNot retriggerable
OFF delay islistNot retriggerable
Warning mode for ending of staircase timerlistNothing
--Warning starts at a staircase timer rest time of (1s*factor)unsignedInt 0…590
Locking functionlistAt object value "1"
Behavior at start of lockinglistNo reaction
Behavior at end of lockinglistNo reaction
Behavior after downloadlistDisabled
Behavior after bus voltage recoverylistDisabled
Locking functionunsignedInt 0…10
Lock 1listAt object value "1"
Lock 1 valve positionlist30
Lock 2listAt object value "1"
Lock 2 valve positionlist30
Priority of lock functionlistPriority of 1 is higher than that of 2
LocklistAt object value "0"
Height position at start of locking inunsignedInt 0…1000
Slat position at start of locking inunsignedInt 0…1000
Status responseunsignedInt 0…10
Output 5~8 config aslistSwitch/Curtain AC/Heating/Cooling/2-pipe
Output 5&6 functionlistDisable
Curtain 3 output is fixed forlistOutput 5(Up/Open) & Output 6(Down/Close)
Valve 3 output is fixed for Output 5listOutput5&6,if 3point,open and close
Output 7&8 functionlistDisable
Curtain 4 output is fixed forlistOutput 7(Up/Open) & Output 8(Down/Close)
Valve 4 output is fixed for Output 7listOutput7&8,if 3point,open and close
Fan 2 output is fixed forlist1level:5; 2level:5&6; 3level: 5&6&7
If Fan 2 set to 1 or 2 level,output 7&8 as switch outputlist<<--Attention
Heat output for 4-pipe valve 2 is Output 5listOutput5&6,if 3point,open and close
Cool output for 4-pipe valve 2 is Output 7listOutput7&8,if 3point,open and close
Output 9~12 config aslistSwitch/Curtain AC/Heating/Cooling/2-pipe
Output 9&10 functionlistDisable
Curtain 5 output is fixed forlistOutput 9(Up/Open) & Output 10(Down/Close)
Valve 5 output is fixed for Output 9listOutput9&10,if 3point,open and close
Output 11&12 functionlistDisable
Curtain 6 output is fixed forlistOutput 11(Up/Open) & Output 12(Down/Close)
Valve 6 output is fixed for Output 11listOutput11&12,if 3point,open and close
Fan 3 output is fixed forlist1level:9; 2level:9&10; 3level: 9&10&11
If Fan 3 set to 1 or 2 level,output 11&12 as switch outputlist<<--Attention
Heat output for 4-pipe valve 3 is Output 9listOutput9&10,if 3point,open and close
Cool output for 4-pipe valve 3 is Output 11listOutput11&12,if 3point,open and close
Output 13~16 config aslistSwitch/Curtain AC/Heating/Cooling/2-pipe
Output 13&14 functionlistDisable
Curtain 7 output is fixed forlistOutput 13(Up/Open) & Output 14(Down/Close)
Valve 7 output is fixed for Output 13listOutput13&14,if 3point,open and close
Output 15&16 functionlistDisable
Curtain 8 output is fixed forlistOutput 15(Up/Open) & Output 16(Down/Close)
Valve 8 output is fixed for Output 15listOutput15&16,if 3point,open and close
Fan 4 output is fixed forlist1level:13; 2level:13&14; 3level: 13&14&15
If Fan 4 set to 1 or 2 level,output 15&16 as switch outputlist<<--Attention
Heat output for 4-pipe valve 4 is Output 13listOutput13&14,if 3point,open and close
Cool output for 4-pipe valve 4 is Output 15listOutput15&16,if 3point,open and close
Output 17~20 config aslistSwitch/Curtain AC/Heating/Cooling/2-pipe
Output 17&18 functionlistDisable
Curtain 9 output is fixed forlistOutput 17(Up/Open) & Output 18(Down/Close)
Valve 9 output is fixed for Output 17listOutput17&18,if 3point,open and close
Output 19&20 functionlistDisable
Curtain 10 output is fixed forlistOutput 19(Up/Open) & Output 20(Down/Close)
Valve 10 output is fixed for Output 19listOutput19&20,if 3point,open and close
Fan 5 output is fixed forlist1level:17; 2level:17&18; 3level: 17&18&19
If Fan 5 set to 1 or 2 level,output 19&20 as switch outputlist<<--Attention
Heat output for 4-pipe valve 5 is Output 17listOutput17&18,if 3point,open and close
Cool output for 4-pipe valve 5 is Output 19listOutput19&20,if 3point,open and close
Output 21~24 config aslistSwitch/Curtain AC/Heating/Cooling/2-pipe
Output 21&22 functionlistDisable
Curtain 11 output is fixed forlistOutput 21(Up/Open) & Output 22(Down/Close)
Valve 11 output is fixed for Output 21listOutput21&22,if 3point,open and close
Output 23&24 functionlistDisable
Curtain 12 output is fixed forlistOutput 23(Up/Open) & Output 24(Down/Close)
Valve 12 output is fixed for Output 23listOutput23&24,if 3point,open and close
Fan 6 output is fixed forlist1level:21; 2level:21&22; 3level: 21&22&23
If Fan 6 set to 1 or 2 level,output 23&24 as switch outputlist<<--Attention
Heat output for 4-pipe valve 6 is Output 21listOutput21&22,if 3point,open and close
Cool output for 4-pipe valve 6 is Output 23listOutput23&24,if 3point,open and close
Limitation on forced operationlistUnchange
Output 2listDisable
Output 3listDisable
Output 4listDisable
Output 6listDisable
Output 7listDisable
Output 8listDisable
Output 5listDisable
Output 9listDisable
Output 10listDisable
Output 11listDisable
Output 12listDisable
Output 13listDisable
Output 14listDisable
Output 15listDisable
Output 16listDisable
Output 17listDisable
Output 18listDisable
Output 19listDisable
Output 20listDisable
Output 21listDisable
Output 22listDisable
Output 23listDisable
Output 24listDisable
Switch function of output 3listDisable
Switch function of output 4listDisable
--(0...10)unsignedInt 0…100
Ouput en/disunsignedInt 0…10
HVAC control modelistHeating and Cooling
Valve control modelist2 state-ON/OFF
Observe reseversing timelist400ms
Value position at bus voltage recoverylistUnchange
Valve control time 0%->100% (10...6000)unsignedInt 10…6000100
Automatic adjust valve positionunsignedInt 0…10
Number of valve control up to adjust (1...65535)unsignedInt 1…65535200
Correct Valve characteristic curveunsignedInt 0…10
Min. controller value for closed valve (0...100)unsignedInt 0…1000
Max. controller value for fully opened valve (0...100)unsignedInt 0…100100
Lower valve position for opening (0...100)unsignedInt 0…1000
Upper valve position for opening (0...100)unsignedInt 0…100100
Reply mode for valve statuslistRespond after change
Object type of valve statuslist1byte
Object value with valve position >0list1
Valve typelistNormal(de-energised closed)
PWM cycle time (10...6000)unsignedInt 10…6000120
Valve purge functionunsignedInt 0…10
Duration of valve purge time (1...255)unsignedInt 1…25510
Automatic valve purgeunsignedInt 0…10
Purge Cycle in weeks (1...12)unsignedInt 1…121
Reply mode for valve purge status(1bit)listRespond after change
"Disable heating" object functionunsignedInt 0…10
Trigger object valuelist0=Disable/1=Enable
"Disable cooling" object functionunsignedInt 0…10
HVAC Systemlist2 pipes system
"Disable heating/cooling" object functionunsignedInt 0…10
Number of control valuelist2 control value
Monitoring period of control value (10...65535)unsignedInt 10…6553560
HVAC Systemlist4 pipes system

Version history

ApplicationApp noFingerprintFirst seenSizeFile
Switch/Curtain/Heating/Cooling 8140/1.2 1.2 latest$814016A42026-11-25178 KBDownload

About this file

This is the official ETS product database for the Schneider Electric Industries SAS Hybrid Switch Actuator REG-K/4x250/10 manual mode (MTN6700-0104), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.

More from Schneider Electric Industries SAS

All Schneider Electric Industries SAS products