KNX Database

Year time switch REG-K/8/800 MTN6606-0008

Schneider Electric Industries SAS · Order number MTN6606-0008 · 3.3 Time function › 3.3.02 Time switch REG-K

MTN6606-0008

Download .knxprod Year time switch 8-channels 7714/1.0 1.0 · 248 KB

Product

ManufacturerSchneider Electric Industries SAS
Product nameYear time switch REG-K/8/800
Order numberMTN6606-0008
HardwareJahreszeitschaltuhr REG-K/8/800
MediumTwisted Pair
Bus current (mA)10
Rail mountedYes
Width (mm)52.5
RegistrationRegistered
Languagesen-US, de-DE, fr-FR, da-DK, nl-NL, it-IT, sv-SE, es-ES
Catalog entryM-0064_H-MTN6606.2D0008-1-O0048_HP-648B-10-4001-O0048_CI-MTN6606.2D0008-1
Fingerprint4001
SHA-256ef192581c0eec8fa89d856357952e31f55c742476f6465cec8a866b543384481
First seen2026-11-25
Markets59 markets

Application program: Year time switch 8-channels 7714/1.0 1.0

Application number$648B
Version1.0
Mask versionMV-0701 (7.1)
KNX Data SecureNo
Parameters1078
Group objects440
Group objects (440)
NoNameFunctionSizeDPTFlags
0Local timeSend3 BytesCRTU
0Local timeReceive3 BytesCRWU
1Local dateSend3 BytesCRTU
1Local dateReceive3 BytesCRWU
2UTC timeSend3 BytesCRTU
3UTC dateSend3 BytesCRTU
4Time queryReceive1 BitCRWU
4Time querySend1 BitCRTU
5Error GPS module0 = OK, 1 = Error1 BitCRTU
5Error DCF module0 = OK, 1 = Error1 BitCRTU
6Date/time (DPT 19.001)Receive8 BytesCRWU
6Date/time (DPT 19.001)Send8 BytesCRTU
7C1.1 switching channelPriority2 BitCRTU
7C1.1 switching channelValue1 ByteCRTU
7C1.1 switching channelScene1 ByteCRTU
7C1.1 switching channelSwitching1 BitCRTU
7C1.1 switching channelPercent1 ByteCRTU
7C1.1 switching channelHVAC operating mode1 ByteCRTU
7C1.1 switching channelTemperature in °C2 BytesCRTU
7C1.1 switching channelTemperature in K2 BytesCRTU
8C1.2 switching channelValue1 ByteCRTU
8C1.2 switching channelSwitching1 BitCRTU
8C1.2 switching channelPercent1 ByteCRTU
8C1.2 switching channelTemperature in K2 BytesCRTU
8C1.2 switching channelHVAC operating mode1 ByteCRTU
8C1.2 switching channelTemperature in °C2 BytesCRTU
9C1 lockLock = 01 BitCRWU
9C1 lockLock = 11 BitCRWU
10C1 switching channelSpecial program1 ByteCRWU
11C1 switching channelTime to next service2 BytesCRTU
11C1 switching channelOperating hours feedback2 BytesCRTU
12C1 switching channelService required1 BitCRTU
13C1 switching channelReset service1 BitCRWU
13C1 switching channelReset operating hours1 BitCRWU
14Object 152 BytesCRWTU
14C2.1 switching channelPercent1 ByteCRTU
14C2.1 switching channelHVAC operating mode1 ByteCRTU
14C2.1 switching channelTemperature in °C2 BytesCRTU
14C2.1 switching channelTemperature in K2 BytesCRTU
14C2.1 switching channelSwitching1 BitCRTU
14C2.1 switching channelValue1 ByteCRTU
14C2.1 switching channelPriority2 BitCRTU
14C2.1 switching channelScene1 ByteCRTU
15Object 162 BytesCRWTU
15C2.2 switching channelPercent1 ByteCRTU
15C2.2 switching channelTemperature in K2 BytesCRTU
15C2.2 switching channelHVAC operating mode1 ByteCRTU
15C2.2 switching channelTemperature in °C2 BytesCRTU
15C2.2 switching channelValue1 ByteCRTU
15C2.2 switching channelSwitching1 BitCRTU
16Object 171 BitCRWTU
16C2 lockLock = 01 BitCRWU
16C2 lockLock = 11 BitCRWU
17Object 181 ByteCRWTU
17C2 switching channelSpecial program1 ByteCRWU
18Object 194 BytesCRWTU
18C2 switching channelTime to next service2 BytesCRTU
18C2 switching channelOperating hours feedback2 BytesCRTU
19Object 201 BitCRWTU
19C2 switching channelService required1 BitCRTU
20Object 211 BitCRWTU
20C2 switching channelReset service1 BitCRWU
20C2 switching channelReset operating hours1 BitCRWU
21Object 222 BytesCRWTU
21C3.1 switching channelHVAC operating mode1 ByteCRTU
21C3.1 switching channelPercent1 ByteCRTU
21C3.1 switching channelTemperature in °C2 BytesCRTU
21C3.1 switching channelTemperature in K2 BytesCRTU
21C3.1 switching channelSwitching1 BitCRTU
21C3.1 switching channelValue1 ByteCRTU
21C3.1 switching channelPriority2 BitCRTU
21C3.1 switching channelScene1 ByteCRTU
22Object 232 BytesCRWTU
22C3.2 switching channelPercent1 ByteCRTU
22C3.2 switching channelTemperature in K2 BytesCRTU
22C3.2 switching channelHVAC operating mode1 ByteCRTU
22C3.2 switching channelTemperature in °C2 BytesCRTU
22C3.2 switching channelValue1 ByteCRTU
22C3.2 switching channelSwitching1 BitCRTU
23Object 241 BitCRWTU
23C3 lockLock = 11 BitCRWU
23C3 lockLock = 01 BitCRWU
24Object 251 ByteCRWTU
24C3 switching channelSpecial program1 ByteCRWU
25Object 262 BytesCRWTU
25C3 switching channelTime to next service2 BytesCRTU
25C3 switching channelOperating hours feedback2 BytesCRTU
26Object 271 BitCRWTU
26C3 switching channelService required1 BitCRTU
27Object 281 BitCRWTU
27C3 switching channelReset service1 BitCRWU
27C3 switching channelReset operating hours1 BitCRWU
28Object 292 BytesCRWTU
28C4.1 switching channelHVAC operating mode1 ByteCRTU
28C4.1 switching channelTemperature in °C2 BytesCRTU
28C4.1 switching channelPercent1 ByteCRTU
28C4.1 switching channelTemperature in K2 BytesCRTU
28C4.1 switching channelSwitching1 BitCRTU
28C4.1 switching channelValue1 ByteCRTU
28C4.1 switching channelPriority2 BitCRTU
28C4.1 switching channelScene1 ByteCRTU
29Object 302 BytesCRWTU
29C4.2 switching channelPercent1 ByteCRTU
29C4.2 switching channelTemperature in K2 BytesCRTU
29C4.2 switching channelHVAC operating mode1 ByteCRTU
29C4.2 switching channelTemperature in °C2 BytesCRTU
29C4.2 switching channelValue1 ByteCRTU
29C4.2 switching channelSwitching1 BitCRTU
30Object 311 BitCRWTU
30C4 lockLock = 01 BitCRWU
30C4 lockLock = 11 BitCRWU
31Object 321 ByteCRWTU
31C4 switching channelSpecial program1 ByteCRWU
32Object 332 BytesCRWTU
32C4 switching channelTime to next service2 BytesCRTU
32C4 switching channelOperating hours feedback2 BytesCRTU
33Object 341 BitCRWTU
33C4 switching channelService required1 BitCRTU
34Object 351 BitCRWTU
34C4 switching channelReset service1 BitCRWU
34C4 switching channelReset operating hours1 BitCRWU
35Object 362 BytesCRWTU
35C5.1 switching channelPercent1 ByteCRTU
35C5.1 switching channelHVAC operating mode1 ByteCRTU
35C5.1 switching channelTemperature in °C2 BytesCRTU
35C5.1 switching channelTemperature in K2 BytesCRTU
35C5.1 switching channelSwitching1 BitCRTU
35C5.1 switching channelValue1 ByteCRTU
35C5.1 switching channelPriority2 BitCRTU
35C5.1 switching channelScene1 ByteCRTU
36Object 372 BytesCRWTU
36C5.2 switching channelPercent1 ByteCRTU
36C5.2 switching channelTemperature in K2 BytesCRTU
36C5.2 switching channelHVAC operating mode1 ByteCRTU
36C5.2 switching channelTemperature in °C2 BytesCRTU
36C5.2 switching channelValue1 ByteCRTU
36C5.2 switching channelSwitching1 BitCRTU
37Object 381 BitCRWTU
37C5 lockLock = 01 BitCRWU
37C5 lockLock = 11 BitCRWU
38Object 391 ByteCRWTU
38C5 switching channelSpecial program1 ByteCRWU
39Object 402 BytesCRWTU
39C5 switching channelTime to next service2 BytesCRTU
39C5 switching channelOperating hours feedback2 BytesCRTU
40Object 411 BitCRWTU
40C5 switching channelService required1 BitCRTU
41Object 421 BitCRWTU
41C5 switching channelReset service1 BitCRWU
41C5 switching channelReset operating hours1 BitCRWU
42Object 432 BytesCRWTU
42C6.1 switching channelTemperature in °C2 BytesCRTU
42C6.1 switching channelTemperature in K2 BytesCRTU
42C6.1 switching channelSwitching1 BitCRTU
42C6.1 switching channelHVAC operating mode1 ByteCRTU
42C6.1 switching channelValue1 ByteCRTU
42C6.1 switching channelPriority2 BitCRTU
42C6.1 switching channelScene1 ByteCRTU
42C6.1 switching channelPercent1 ByteCRTU
43Object 442 BytesCRWTU
43C6.2 switching channelPercent1 ByteCRTU
43C6.2 switching channelTemperature in K2 BytesCRTU
43C6.2 switching channelHVAC operating mode1 ByteCRTU
43C6.2 switching channelTemperature in °C2 BytesCRTU
43C6.2 switching channelValue1 ByteCRTU
43C6.2 switching channelSwitching1 BitCRTU
44Object 451 BitCRWTU
44C6 lockLock = 01 BitCRWU
44C6 lockLock = 11 BitCRWU
45Object 461 ByteCRWTU
45C6 switching channelSpecial program1 ByteCRWU
46Object 472 BytesCRWTU
46C6 switching channelTime to next service2 BytesCRTU
46C6 switching channelOperating hours feedback2 BytesCRTU
47Object 481 BitCRWTU
47C6 switching channelService required1 BitCRTU
48Object 491 BitCRWTU
48C6 switching channelReset service1 BitCRWU
48C6 switching channelReset operating hours1 BitCRWU
49Object 502 BytesCRWTU
49C7.1 switching channelPercent1 ByteCRTU
49C7.1 switching channelHVAC operating mode1 ByteCRTU
49C7.1 switching channelTemperature in °C2 BytesCRTU
49C7.1 switching channelTemperature in K2 BytesCRTU
49C7.1 switching channelSwitching1 BitCRTU
49C7.1 switching channelValue1 ByteCRTU
49C7.1 switching channelPriority2 BitCRTU
49C7.1 switching channelScene1 ByteCRTU
50Object 512 BytesCRWTU
50C7.2 switching channelPercent1 ByteCRTU
50C7.2 switching channelTemperature in K2 BytesCRTU
50C7.2 switching channelHVAC operating mode1 ByteCRTU
50C7.2 switching channelTemperature in °C2 BytesCRTU
50C7.2 switching channelValue1 ByteCRTU
50C7.2 switching channelSwitching1 BitCRTU
51Object 521 BitCRWTU
51C7 lockLock = 11 BitCRWU
51C7 lockLock = 01 BitCRWU
52Object 531 ByteCRWTU
52C7 switching channelSpecial program1 ByteCRWU
53Object 542 BytesCRWTU
53C7 switching channelTime to next service2 BytesCRTU
53C7 switching channelOperating hours feedback2 BytesCRTU
54Object 551 BitCRWTU
54C7 switching channelService required1 BitCRTU
55Object 561 BitCRWTU
55C7 switching channelReset service1 BitCRWU
55C7 switching channelReset operating hours1 BitCRWU
56Object 572 BytesCRWTU
56C8.1 switching channelPercent1 ByteCRTU
56C8.1 switching channelHVAC operating mode1 ByteCRTU
56C8.1 switching channelTemperature in °C2 BytesCRTU
56C8.1 switching channelTemperature in K2 BytesCRTU
56C8.1 switching channelSwitching1 BitCRTU
56C8.1 switching channelValue1 ByteCRTU
56C8.1 switching channelPriority2 BitCRTU
56C8.1 switching channelScene1 ByteCRTU
57Object 582 BytesCRWTU
57C8.2 switching channelPercent1 ByteCRTU
57C8.2 switching channelTemperature in K2 BytesCRTU
57C8.2 switching channelHVAC operating mode1 ByteCRTU
57C8.2 switching channelTemperature in °C2 BytesCRTU
57C8.2 switching channelValue1 ByteCRTU
57C8.2 switching channelSwitching1 BitCRTU
58Object 591 BitCRWTU
58C8 lockLock = 01 BitCRWU
58C8 lockLock = 11 BitCRWU
59Object 601 ByteCRWTU
59C8 switching channelSpecial program1 ByteCRWU
60Object 614 BytesCRWTU
60C8 switching channelTime to next service2 BytesCRTU
60C8 switching channelOperating hours feedback2 BytesCRTU
61Object 621 BitCRWTU
61C8 switching channelService required1 BitCRTU
62Object 631 BitCRWTU
62C8 switching channelReset service1 BitCRWU
62C8 switching channelReset operating hours1 BitCRWU
63C9 threshold switch inputEIS 52 BytesCRWU
63C9 threshold switch input0..655352 BytesCRWU
63C9 threshold switch input0..2551 ByteCRWU
63C9 threshold switch input Percent1 ByteCRWU
64C9 lockLock = 11 BitCRWU
64C9 lockLock = 01 BitCRWU
65C9.1 Threshold switchValue1 ByteCRTU
65C9.1 Threshold switchSwitching1 BitCRTU
65C9.1 Threshold switchPriority2 BitCRTU
66C9.2 Threshold switchValue1 ByteCRTU
66C9.2 Threshold switchPriority2 BitCRTU
66C9.2 Threshold switchSwitching1 BitCRTU
67C10 threshold switch inputPercent1 ByteCRWU
67C10 threshold switch input0..2551 ByteCRWU
67C10 threshold switch input0..655352 BytesCRWU
67C10 threshold switch inputEIS 52 BytesCRWU
67Object 68Percent2 BytesCRWTU
68Object 691 BitCRWTU
68C10 lockLock = 11 BitCRWU
68C10 lockLock = 01 BitCRWU
69C10.1 Threshold switchPriority2 BitCRTU
69Object 70Priority1 ByteCRWTU
69C10.1 Threshold switchSwitching1 BitCRTU
69C10.1 Threshold switchValue1 ByteCRTU
70C10.2 Threshold switchValue1 ByteCRTU
70C10.2 Threshold switchPriority2 BitCRTU
70C10.2 Threshold switchSwitching1 BitCRTU
70Object 71Value1 ByteCRWTU
71C11 threshold switch inputPercent1 ByteCRWU
71C11 threshold switch input0..2551 ByteCRWU
71C11 threshold switch input0..655352 BytesCRWU
71C11 threshold switch inputEIS 52 BytesCRWU
71Object 72Percent2 BytesCRWTU
72C11 lockLock = 01 BitCRWU
72C11 lockLock = 11 BitCRWU
72Object 73Lock = 01 BitCRWTU
73C11.1 Threshold switchSwitching1 BitCRTU
73C11.1 Threshold switchValue1 ByteCRTU
73C11.1 Threshold switchPriority2 BitCRTU
73Object 74Switching1 ByteCRWTU
74C11.2 Threshold switchValue1 ByteCRTU
74C11.2 Threshold switchPriority2 BitCRTU
74C11.2 Threshold switchSwitching1 BitCRTU
74Object 75Value1 ByteCRWTU
75C12 threshold switch inputPercent1 ByteCRWU
75C12 threshold switch input0..2551 ByteCRWU
75C12 threshold switch input0..655352 BytesCRWU
75C12 threshold switch inputEIS 52 BytesCRWU
75Object 76Percent2 BytesCRWTU
76C12 lockLock = 11 BitCRWU
76C12 lockLock = 01 BitCRWU
76Object 77Lock = 11 BitCRWTU
77C12.1 Threshold switchSwitching1 BitCRTU
77C12.1 Threshold switchValue1 ByteCRTU
77C12.1 Threshold switchPriority2 BitCRTU
77Object 78Switching1 ByteCRWTU
78C12.2 Threshold switchValue1 ByteCRTU
78C12.2 Threshold switchPriority2 BitCRTU
78C12.2 Threshold switchSwitching1 BitCRTU
78Object 79Value1 ByteCRWTU
79C13 Logic moduleLogic input 1 in XOR gate1 BitCRWU
79C13 Logic moduleLogic input 1 in OR gate1 BitCRWU
79C13 Logic moduleLogic input 1 in AND gate1 BitCRWU
80C13 Logic moduleLogic input 2 in XOR gate1 BitCRWU
80C13 Logic moduleLogic input 2 in OR gate1 BitCRWU
80C13 Logic moduleLogic input 2 in AND gate1 BitCRWU
81C13 Logic moduleLogic input 3 in AND gate1 BitCRWU
81C13 Logic moduleLogic input 3 in OR gate1 BitCRWU
82C13 Logic moduleLogic input 4 in OR gate1 BitCRWU
82C13 Logic moduleLogic input 4 in AND gate1 BitCRWU
83C13 Logic moduleLock = 01 BitCRWU
83C13 Logic moduleLock = 11 BitCRWU
84C13.1 Logic moduleValue1 ByteCRTU
84C13.1 Logic modulePriority2 BitCRTU
84C13.1 Logic moduleSwitching1 BitCRTU
85C13.2 Logic moduleValue1 ByteCRTU
85C13.2 Logic modulePriority2 BitCRTU
85C13.2 Logic moduleSwitching1 BitCRTU
86C14 Logic moduleLogic input 1 in OR gate1 BitCRWU
86C14 Logic moduleLogic input 1 in AND gate1 BitCRWU
86C14 Logic moduleLogic input 1 in XOR gate1 BitCRWU
86Object 87Logic input 1 in OR gate1 BitCRWTU
87C14 Logic moduleLogic input 2 in OR gate1 BitCRWU
87C14 Logic moduleLogic input 2 in AND gate1 BitCRWU
87C14 Logic moduleLogic input 2 in XOR gate1 BitCRWU
87Object 88Logic input 2 in OR gate1 BitCRWTU
88C14 Logic moduleLogic input 3 in OR gate1 BitCRWU
88C14 Logic moduleLogic input 3 in AND gate1 BitCRWU
88Object 89Logic input 3 in OR gate1 BitCRWTU
89C14 Logic moduleLogic input 4 in OR gate1 BitCRWU
89C14 Logic moduleLogic input 4 in AND gate1 BitCRWU
89Object 90Logic input 4 in OR gate1 BitCRWTU
90C14 Logic moduleLock = 11 BitCRWU
90C14 Logic moduleLock = 01 BitCRWU
90Object 91Lock = 11 BitCRWTU
91C14.1 Logic modulePriority2 BitCRTU
91C14.1 Logic moduleSwitching1 BitCRTU
91C14.1 Logic moduleValue1 ByteCRTU
91Object 92Priority1 ByteCRWTU
92C14.2 Logic moduleValue1 ByteCRTU
92C14.2 Logic modulePriority2 BitCRTU
92C14.2 Logic moduleSwitching1 BitCRTU
92Object 93Value1 ByteCRWTU
93C15 Logic moduleLogic input 1 in OR gate1 BitCRWU
93C15 Logic moduleLogic input 1 in AND gate1 BitCRWU
93C15 Logic moduleLogic input 1 in XOR gate1 BitCRWU
93Object 94Logic input 1 in OR gate1 BitCRWTU
94C15 Logic moduleLogic input 2 in OR gate1 BitCRWU
94C15 Logic moduleLogic input 2 in AND gate1 BitCRWU
94C15 Logic moduleLogic input 2 in XOR gate1 BitCRWU
94Object 95Logic input 2 in OR gate1 BitCRWTU
95C15 Logic moduleLogic input 3 in OR gate1 BitCRWU
95C15 Logic moduleLogic input 3 in AND gate1 BitCRWU
95Object 96Logic input 3 in OR gate1 BitCRWTU
96C15 Logic moduleLogic input 4 in OR gate1 BitCRWU
96C15 Logic moduleLogic input 4 in AND gate1 BitCRWU
96Object 97Logic input 4 in OR gate1 BitCRWTU
97C15 Logic moduleLock = 01 BitCRWU
97C15 Logic moduleLock = 11 BitCRWU
97Object 98Lock = 01 BitCRWTU
98C15.1 Logic modulePriority2 BitCRTU
98C15.1 Logic moduleSwitching1 BitCRTU
98C15.1 Logic moduleValue1 ByteCRTU
98Object 99Priority1 ByteCRWTU
99C15.2 Logic moduleValue1 ByteCRTU
99C15.2 Logic modulePriority2 BitCRTU
99C15.2 Logic moduleSwitching1 BitCRTU
99Object 100Value1 ByteCRWTU
100C16 Logic module Logic input 1 in XOR gate1 BitCRWU
100C16 Logic module Logic input 1 in AND gate1 BitCRWU
100C16 Logic module Logic input 1 in OR gate1 BitCRWU
100Object 101Logic input 1 in XOR gate1 BitCRWTU
101C16 Logic module Logic input 2 in XOR gate1 BitCRWU
101C16 Logic module Logic input 2 in AND gate1 BitCRWU
101C16 Logic module Logic input 2 in OR gate1 BitCRWU
101Object 102Logic input 2 in XOR gate1 BitCRWTU
102C16 Logic module Logic input 3 in AND gate1 BitCRWU
102C16 Logic module Logic input 3 in OR gate1 BitCRWU
102Object 103Logic input 3 in AND gate1 BitCRWTU
103C16 Logic module Logic input 4 in AND gate1 BitCRWU
103C16 Logic module Logic input 4 in OR gate1 BitCRWU
103Object 104Logic input 4 in AND gate1 BitCRWTU
104C16 Logic module Lock = 11 BitCRWU
104C16 Logic module Lock = 01 BitCRWU
104Object 105Lock = 11 BitCRWTU
105C16.1 Logic modulePriority2 BitCRTU
105C16.1 Logic moduleSwitching1 BitCRTU
105C16.1 Logic moduleValue1 ByteCRTU
105Object 106Priority1 ByteCRWTU
106C16.2 Logic moduleValue1 ByteCRTU
106C16.2 Logic modulePriority2 BitCRTU
106C16.2 Logic moduleSwitching1 BitCRTU
106Object 107Value1 ByteCRWTU
107C17 Logic module Logic input 1 in XOR gate1 BitCRWU
107C17 Logic module Logic input 1 in AND gate1 BitCRWU
107C17 Logic module Logic input 1 in OR gate1 BitCRWU
107Object 108Logic input 1 in XOR gate1 BitCRWTU
108C17 Logic module Logic input 2 in XOR gate1 BitCRWU
108C17 Logic module Logic input 2 in AND gate1 BitCRWU
108C17 Logic module Logic input 2 in OR gate1 BitCRWU
108Object 109Logic input 2 in XOR gate1 BitCRWTU
109C17 Logic module Logic input 3 in AND gate1 BitCRWU
109C17 Logic module Logic input 3 in OR gate1 BitCRWU
109Object 110Logic input 3 in AND gate1 BitCRWTU
110C17 Logic module Logic input 4 in AND gate1 BitCRWU
110C17 Logic module Logic input 4 in OR gate1 BitCRWU
110Object 111Logic input 4 in AND gate1 BitCRWTU
111C17 Logic module Lock = 01 BitCRWU
111C17 Logic module Lock = 11 BitCRWU
111Object 112Lock = 01 BitCRWTU
112C17.1 Logic modulePriority2 BitCRTU
112C17.1 Logic moduleSwitching1 BitCRTU
112C17.1 Logic moduleValue1 ByteCRTU
112Object 113Priority1 ByteCRWTU
113C17.2 Logic moduleValue1 ByteCRTU
113C17.2 Logic modulePriority2 BitCRTU
113C17.2 Logic moduleSwitching1 BitCRTU
113Object 114Value1 ByteCRWTU
114C18 Logic module Logic input 1 in OR gate1 BitCRWU
114C18 Logic module Logic input 1 in XOR gate1 BitCRWU
114C18 Logic module Logic input 1 in AND gate1 BitCRWU
114Object 115Logic input 1 in OR gate1 BitCRWTU
115C18 Logic module Logic input 2 in OR gate1 BitCRWU
115C18 Logic module Logic input 2 in XOR gate1 BitCRWU
115C18 Logic module Logic input 2 in AND gate1 BitCRWU
115Object 116Logic input 2 in OR gate1 BitCRWTU
116C18 Logic module Logic input 3 in OR gate1 BitCRWU
116C18 Logic module Logic input 3 in AND gate1 BitCRWU
116Object 117Logic input 3 in OR gate1 BitCRWTU
117C18 Logic module Logic input 4 in OR gate1 BitCRWU
117C18 Logic module Logic input 4 in AND gate1 BitCRWU
117Object 118Logic input 4 in OR gate1 BitCRWTU
118C18 Logic module Lock = 01 BitCRWU
118C18 Logic module Lock = 11 BitCRWU
118Object 119Lock = 01 BitCRWTU
119C18.1 Logic modulePriority2 BitCRTU
119C18.1 Logic moduleSwitching1 BitCRTU
119C18.1 Logic moduleValue1 ByteCRTU
119Object 120Priority1 ByteCRWTU
120C18.2 Logic moduleValue1 ByteCRTU
120C18.2 Logic modulePriority2 BitCRTU
120C18.2 Logic moduleSwitching1 BitCRTU
120Object 121Value1 ByteCRWTU
Parameters (124)
ParameterTypeDefault
Activate time switch channel C1listyes..
Activate time switch channel C2listyes..
Activate time switch channel C3listyes..
Activate time switch channel C4listyes..
Activate time switch channel C5listno
Activate time switch channel C6listno
Activate time switch channel C7listno
Activate time switch channel C8listno
Activating threshold channel C9listno
Activating threshold channel C10listno
Activating threshold channel C11listno
Activating threshold channel C12listno
Activating logic channel C13listno
Activating logic channel C14listno
Activating logic channel C15listno
Activating logic channel C16listno
Activating logic channel C17listno
Activating logic channel C18listno
Mode of operation of object time and datelistsend time and date
Send time and datelistevery hour
Format of time and date telegramsliststandard (DPT 10.001 + DPT 11.001)
Type of antennalistnone
Send time request cyclicallylistevery 2 hours
Telegram type C1.1listswitching command
When clock -> ONlistsend following telegram once
Telegramlistscene 1
Telegramlistpriority, ON (down)
TelegramunsignedInt 0…255255
Telegramlist ON
Telegramliststandby
Telegram (°C)unsignedInt 0…10018
Telegram (K)signedInt -50…502
Telegram (%)unsignedInt 0…100100
When clock -> OFFlistsend following telegram once
Telegramlistpriority, OFF (up)
Telegramlistscene 2
TelegramunsignedInt 0…2550
Telegramlist OFF
Telegram (%)unsignedInt 0…1000
Telegramlistnight-time temperature reduction
Telegram (°C)unsignedInt 0…10016
Telegram (K)signedInt -50…50-2
Should a second telegram be sent?listno
Telegram type C1.2listswitching command
Activate lock functionlistno
Activate operating hours counterlistno
Cycle time (if used)listevery 60 minutes
Lock telegramlistlock with ON telegram
Behaviour when setting the locklistdo not send
Behaviour when cancelling the locklistupdate channel
After downloadlistyes
After restoration of bus supplylistyes
After changing the timelistonly with status change
After programming/deleting a time commandlistonly with status change
After changing a special programlistonly with status change
Type of operating hours counterlistoperating hours counter
Service interval (1..32767 h)unsignedInt 1…32767100
Reporting of changes to operating hours (0..100 h, 0 = no report)unsignedInt 0…10010
Reporting of changes to time to service (0..100 h, 0 = no report)unsignedInt 0…10010
Report operating hours cyclicallylistno
Report time to service cyclicallylistno
Report service cyclicallylistno
Time for cyclical transmissionlist 60 min.
Time for cyclical transmission (time to service and service)list 60 min.
Telegram type C2.1listswitching command
Telegram type C2.2listswitching command
Telegram type C3.1listswitching command
Telegram type C3.2listswitching command
Telegram type C4.1listswitching command
Telegram type C4.2listswitching command
Telegram type C5.1listswitching command
Telegram type C5.2listswitching command
Telegram type C6.1listswitching command
Telegram type C6.2listswitching command
Telegram type C7.1listswitching command
Telegram type C7.2listswitching command
Telegram type C8.1listswitching command
Telegram type C8.2listswitching command
Type of threshold value objectlistobject type: Per cent (DPT 5.001)
Threshold value format: (-)000.00..99999text20,0
Threshold value (in %)unsignedInt 1…9950
Threshold valueunsignedInt 1…254127
Threshold valueunsignedInt 1…655341000
Hysteresis format: 0.00..9999text1,0
Hysteresis (as %)unsignedInt 1…995
HysteresisunsignedInt 1…2545
HysteresisunsignedInt 1…655345
Delay with exceedinglistnone
Delay with falling belowlistnone
Telegram type C9.1listswitching command
When exceeding the thresholdlistsend following telegram once
When underrunning thresholdlistsend following telegram once
Telegram type C9.2listswitching command
Telegram after reset or downloadlistas with unfulfilled condition
Telegram type C10.1listswitching command
Telegram type C10.2listswitching command
Telegram type C11.1listswitching command
Telegram type C11.2listswitching command
Telegram type C12.1listswitching command
Telegram type C12.2listswitching command
Type of linklistAND
Use input 1listyes
Use input 2listyes
Use input 3listno
Use input 4listno
Input size for input 1listinput object
Input size for input 2listinput object
Input size for input 3listinput object
Input size for input 4listinput object
Telegram type C13.1listswitching command
If the condition is metlistsend following telegram once
If the condition is not metlistsend following telegram once
Telegram type C13.2listswitching command
Invert outputlistno
Telegram type C14.1listswitching command
Telegram type C14.2listswitching command
Telegram type C15.1listswitching command
Telegram type C15.2listswitching command
Telegram type C16.1listswitching command
Telegram type C16.2listswitching command
Telegram type C17.1listswitching command
Telegram type C17.2listswitching command
Telegram type C18.1listswitching command
Telegram type C18.2listswitching command

Version history

ApplicationApp noFingerprintFirst seenSizeFile
Year time switch 8-channels 7714/1.0 1.0 latest$648B40012026-11-25248 KBDownload

About this file

This is the official ETS product database for the Schneider Electric Industries SAS Year time switch REG-K/8/800 (MTN6606-0008), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.

More from Schneider Electric Industries SAS

All Schneider Electric Industries SAS products