| General | list | Dummy |
| Internal ETS identification high | unsignedInt 66…100 | 68 |
| Internal ETS identification low | unsignedInt 50…50 | 50 |
| Internal ETS version high | unsignedInt 64…64 | 64 |
| Internal ETS version low | unsignedInt 0…0 | 0 |
| Channel 1 | list | Deactivated |
| Channel 2 | list | Deactivated |
| Channel 3 | list | Deactivated |
| Channel 4 | list | Deactivated |
| Scenes | list | Disabled |
| Extension unit scenes | list | Disabled |
| Central function | list | Disabled |
| Switching object central | list | Activated |
| Central dimming object | list | Deactivated |
| Central value object | list | Deactivated |
| Same dimming time
at central function and scenes | list | Disabled |
| Channel operation | list | Enabled |
| Extension inputs | list | Enabled |
| Status error | list | Deactivated |
| Same dimming time | list | Dummy |
| Time base for same dimming time | list | 1 s |
| Time factor for same dimming time 1-255 | unsignedInt 1…255 | 5 |
| Time factor for same dimming time
changeable via bus | list | Deactivated |
| 1: General | list | Dummy |
| Minimum dimming value in % | unsignedInt 1…100 | 15 |
| Maximum dimming value in % | unsignedInt 1…100 | 100 |
| Starting behaviour | list | Max. brightness |
| Initial brightness in % | unsignedInt 5…100 | 100 |
| Base dimming curve | list | Incandescent lamps |
| Dimming object switches channel | list | Only ON, not OFF |
| Value object switches channel | list | ON and OFF |
| Extension input influences | list | Switching object |
| Extension input | list | Enabled |
| Delay times | list | Disabled |
| Staircase lighting function | list | Deactivated |
| Switching object effective | list | Unchanged |
| Higher level function | list | Deactivated |
| Disable function | list | Deactivated |
| Behaviour on bus voltage recovery
and download | list | No reaction |
| Status switch | list | Deactivated |
| Status value object/brightness value | list | Deactivated |
| 1: Base dimming curve | list | Dummy |
| 1st threshold value in % | unsignedInt 0…100 | 25 |
| 2nd threshold value in % | unsignedInt 0…100 | 50 |
| 3rd threshold value in % | unsignedInt 0…100 | 75 |
| Time base of 1st dimming section | list | 100 ms |
| Time factor of 1st dimming section
(1-255) | unsignedInt 1…255 | 230 |
| Time base of 2nd dimming section | list | 100 ms |
| Time factor of 2nd dimming section
(1-255) | unsignedInt 1…255 | 180 |
| Time base of 3rd dimming section | list | 100 ms |
| Time factor of 3rd dimming section
(1-255) | unsignedInt 1…255 | 120 |
| Time base of 4th dimming section | list | 100 ms |
| Time factor of 4th dimming section
(1-255) | unsignedInt 1…255 | 70 |
| 1: Dimming time reduction | list | Dummy |
| Dimming time reduction object
for dimming curve | list | Deactivated |
| Format of dimming time reduction | list | 1-100 % |
| For switching telegrams and
staircase lighting switch on at | list | 2 % |
| For switching telegrams and
staircase lighting switch on at x/2.55 % | unsignedInt 1…255 | 5 |
| For dimming telegrams to | list | 6 % |
| For dimming telegrams
to x/2.55 % | unsignedInt 1…255 | 16 |
| For staircase lighting switch off at | list | 50 % |
| For staircase lighting switch off
at x/2.55 % | unsignedInt 1…255 | 128 |
| For value telegrams at | list | 20 % |
| For value telegrams
at x/2.55 % | unsignedInt 1…255 | 51 |
| For scene telegrams at | list | 32 % |
| For scene telegrams
at x/2.55 % | unsignedInt 1…255 | 82 |
| For higher level functions at | list | 2 % |
| For higher level functions
at x/2.55 % | unsignedInt 1…255 | 5 |
| Set 1 - 3 | list | Disabled |
| For switching telegrams and
staircase lighting switch on at | list | 6 % |
| For switching telegrams and
staircase lighting switch on at x/2.55 % | unsignedInt 1…255 | 15 |
| For dimming telegrams to | list | 20 % |
| For dimming telegrams
to x/2.55 % | unsignedInt 1…255 | 51 |
| For staircase lighting switch off at | list | 70 % |
| For staircase lighting switch off
at x/2.55 % | unsignedInt 1…255 | 179 |
| For value telegrams at | list | 30 % |
| For value telegrams
at x/2.55 % | unsignedInt 1…255 | 77 |
| For scene telegrams at | list | 70 % |
| For scene telegrams
at x/2.55 % | unsignedInt 1…255 | 179 |
| For higher level functions at | list | 5 % |
| For higher level functions
at x/2.55 % | unsignedInt 1…255 | 13 |
| For switching telegrams and
staircase lighting switch on at | list | 3 % |
| For switching telegrams and
staircase lighting switch on at x/2.55 % | unsignedInt 1…255 | 8 |
| For dimming telegrams to | list | 15 % |
| For dimming telegrams
to x/2.55 % | unsignedInt 1…255 | 38 |
| For staircase lighting switch off at | list | 40 % |
| For staircase lighting switch off
at x/2.55 % | unsignedInt 1…255 | 102 |
| For value telegrams at | list | 15 % |
| For value telegrams
at x/2.55 % | unsignedInt 1…255 | 38 |
| For scene telegrams at | list | 25 % |
| For scene telegrams
at x/2.55 % | unsignedInt 1…255 | 64 |
| For higher level functions at | list | 3 % |
| For higher level functions
at x/2.55 % | unsignedInt 1…255 | 8 |
| For switching telegrams and
staircase lighting switch on at | list | 1 % |
| For switching telegrams and
staircase lighting switch on at x/2.55 % | unsignedInt 1…255 | 3 |
| For dimming telegrams to | list | 7 % |
| For dimming telegrams
to x/2.55 % | unsignedInt 1…255 | 18 |
| For staircase lighting switch off at | list | 25 % |
| For staircase lighting switch off
at x/2.55 % | unsignedInt 1…255 | 64 |
| For value telegrams at | list | 10 % |
| For value telegrams
at x/2.55 % | unsignedInt 1…255 | 26 |
| For scene telegrams at | list | 20 % |
| For scene telegrams
at x/2.55 % | unsignedInt 1…255 | 51 |
| For higher level functions at | list | 1 % |
| For higher level functions
at x/2.55 % | unsignedInt 1…255 | 3 |
| 1: Delay times | list | Dummy |
| ON delay | list | Deactivated |
| Output during ON delay | list | Switched off |
| Time base for ON delay | list | 1 min. |
| Time factor for ON delay (1-255) | unsignedInt 1…255 | 3 |
| OFF delay | list | Deactivated |
| Time base for OFF delay | list | 1 min. |
| Time factor for OFF delay (1-255) | unsignedInt 1…255 | 3 |
| 1: Staircase timer | list | Dummy |
| Staircase lighting function | list | Not retriggerable with manual OFF |
| Time base for staircase timer | list | 1 min. |
| Max. number of time accumulations
(1-255) | unsignedInt 1…255 | 3 |
| Time factor for staircase timer (1-255) | unsignedInt 1…255 | 3 |
| Staircase lighting object effective | list | Unchanged |
| Staircase lighting object | list | Unchanged |
| Disconnection warning
for staircase timer | list | Deactivated |
| Warning time for staircase timer
in seconds (1-255) | unsignedInt 1…255 | 30 |
| 1: Scenes | list | Dummy |
| Overwrite scene values in the actuator
during download | list | Activated |
| Same dimming time | list | Deactivated |
| Scene 1 | list | Deactivated |
| Scene 1: Scene number (0-63) | unsignedInt 0…63 | 0 |
| Scene 1: Brightness value in % | unsignedInt 0…100 | 15 |
| Scene 2 | list | Deactivated |
| Scene 2: Scene number (0-63) | unsignedInt 0…63 | 1 |
| Scene 2: Brightness value in % | unsignedInt 0…100 | 35 |
| Scene 3 | list | Deactivated |
| Scene 3: Scene number (0-63) | unsignedInt 0…63 | 2 |
| Scene 3: Brightness value in % | unsignedInt 0…100 | 50 |
| Scene 4 | list | Deactivated |
| Scene 4: Scene number (0-63) | unsignedInt 0…63 | 3 |
| Scene 4: Brightness value in % | unsignedInt 0…100 | 65 |
| Scene 5 | list | Deactivated |
| Scene 5: Scene number (0-63) | unsignedInt 0…63 | 4 |
| Scene 5: Brightness value in % | unsignedInt 0…100 | 80 |
| Scene 6 | list | Deactivated |
| Scene 6: Scene number (0-63) | unsignedInt 0…63 | 5 |
| Scene 6: Brightness value in % | unsignedInt 0…100 | 80 |
| Scene 7 | list | Deactivated |
| Scene 7: Scene number (0-63) | unsignedInt 0…63 | 6 |
| Scene 7: Brightness value in % | unsignedInt 0…100 | 80 |
| Scene 8 | list | Deactivated |
| Scene 8: Scene number (0-63) | unsignedInt 0…63 | 7 |
| Scene 8: Brightness value in % | unsignedInt 0…100 | 80 |
| 1: Central function | list | Dummy |
| Function at switching object central = 0 | list | Switch off |
| Desired brightness at
switching object central = 0 in % | unsignedInt 5…100 | 100 |
| Function at switching object central = 1 | list | Switch on at selectable brightness |
| Desired brightness at
switching object central = 1 in % | unsignedInt 5…100 | 100 |
| 1: Logic operation | list | Dummy |
| Logic operation | list | OR |
| Logic object effective | list | Unchanged |
| Value of logic object after
bus voltage recovery and download | list | 1 |
| Brightness at logic object "0"
in % | unsignedInt 0…100 | 0 |
| Brightness at logic object "1"
in % | unsignedInt 0…100 | 0 |
| 1: Priority control | list | Dummy |
| Behaviour at start
of priority control "ON" | list | Switch on at selectable brightness |
| Desired brightness at start of
priority control "ON" in % | unsignedInt 5…100 | 100 |
| Behaviour at start
of priority control "OFF" | list | Switch off |
| Desired brightness at start of
priority control "OFF" in % | unsignedInt 5…100 | 100 |
| Behaviour at end of priority control | list | Follows secondary functions |
| Desired brightness at end of
priority control in % | unsignedInt 5…100 | 100 |
| Behaviour of priority control after
bus voltage recovery | list | Inactive |
| 1: Disable function | list | Dummy |
| Locking | list | At object value "1" |
| Behaviour at the start of locking | list | No reaction |
| Desired brightness at start of
disable function in % | unsignedInt 5…100 | 100 |
| Behaviour at the end of locking | list | No reaction |
| Desired brightness at end of
disable function in % | unsignedInt 5…100 | 100 |
| Status of locking after
bus voltage recovery | list | Inactive |
| 2: General | list | Dummy |
| 2: Base dimming curve | list | Dummy |
| 2: Dimming time reduction | list | Dummy |
| 2: Delay times | list | Dummy |
| 2: Staircase timer | list | Dummy |
| 2: Scenes | list | Dummy |
| 2: Central function | list | Dummy |
| 2: Logic operation | list | Dummy |
| 2: Priority control | list | Dummy |
| 2: Disable function | list | Dummy |
| 3: General | list | Dummy |
| 3: Base dimming curve | list | Dummy |
| 3: Dimming time reduction | list | Dummy |
| 3: Delay times | list | Dummy |
| 3: Staircase timer | list | Dummy |
| 3: Scenes | list | Dummy |
| 3: Central function | list | Dummy |
| 3: Logic operation | list | Dummy |
| 3: Priority control | list | Dummy |
| 3: Disable function | list | Dummy |
| 4: General | list | Dummy |
| 4: Base dimming curve | list | Dummy |
| 4: Dimming time reduction | list | Dummy |
| 4: Delay times | list | Dummy |
| 4: Staircase timer | list | Dummy |
| 4: Scenes | list | Dummy |
| 4: Central function | list | Dummy |
| 4: Logic operation | list | Dummy |
| 4: Priority control | list | Dummy |
| 4: Disable function | list | Dummy |