4 Gang Dimming Actuator 250W DM104 WRKT5414J-XXX
Panasonic · Order number WRKT5414J-XXX · Lighting › Dimmer
4 Channels Dimming Actuator 250W
Download .knxprod Dim-Act-4Ch 1.0 · 84 KB
Product
| Manufacturer | Panasonic |
|---|---|
| Product name | 4 Gang Dimming Actuator 250W DM104 |
| Order number | WRKT5414J-XXX |
| Product text | 4 Gang Dimming Actuator 250W DM104 |
| Hardware | HW 4 Ch Dimming Actuator |
| Medium | Twisted Pair |
| Rail mounted | Yes |
| Registration | Certified · 2018-12-14 |
| Catalog entry | M-008B_H-805285.2DP-1_HP-0305-10-3C63_CI-WRKT5414J.2DXXX-1 |
| Fingerprint | 3C63 |
| SHA-256 | d8eaad696fc93902a38208b445d119570fe229c04ef1def79604d270d13edba1 |
| First seen | 2026-11-25 |
| Markets | 59 markets |
Application program: Dim-Act-4Ch 1.0
| Application number | $0305 |
|---|---|
| Version | 1.0 |
| Mask version | MV-0705 (7.5) |
| KNX Data Secure | No |
| Minimum ETS version | 4.0 |
| Parameters | 247 |
| Group objects | 70 |
Group objects (70)
| No | Name | Function | Size | DPT | Flags |
|---|---|---|---|---|---|
| 0 | Channel 1 Switching | Switch On/Off | 1 Bit | 1.1 switch | CWU |
| 1 | Channel 1 Dimming | Relative dimming | 4 Bit | 3.7 dimming control | CRWU |
| 2 | Channel 1 Dimming | Absolute dimming | 1 Byte | 5.1 percentage (0..100%) | CWU |
| 3 | Channel 1 Switching | Soft switching | 1 Bit | 1.1 switch | CWU |
| 4 | Channel 1 Feedback | Switch On Off feedback | 1 Bit | 1.1 switch | CRTU |
| 5 | Channel 1 Feedback | Brightness feedback | 1 Byte | 5.1 percentage (0..100%) | CRTU |
| 6 | Channel 1 Supplementary | Disable | 1 Bit | 1.1 switch | CRWU |
| 7 | Channel 1 Supplementary | Forced position | 2 Bit | 2.1 switch control | CRWU |
| 8 | Channel 1 Logic | OR | 1 Bit | 1.1 switch | CRWU |
| 8 | Channel 1 Logic | AND | 1 Bit | 1.1 switch | CRWU |
| 9 | Channel 1 Warning | Short circuit / High load | 1 Bit | 1.5 alarm | CRTU |
| 10 | Channel 1 Warning | Over temperature | 1 Bit | 1.5 alarm | CRTU |
| 11 | Channel 1 Warning | Overload | 1 Bit | 1.5 alarm | CRTU |
| 12 | Channel 1 Counter | Operating hours counter (h) | 2 Bytes | 7.7 time (h) | CRTU |
| 13 | Channel 1 Counter | Restart hours counters | 1 Bit | 1.1 switch | CWU |
| 14 | Channel 1 Status | Channel Status | 1 Bit | 1.3 enable | CRTU |
| 15 | Channel 1 Counter | Operating hours counter (s) | 4 Bytes | 13.100 time lag (s) | CRTU |
| 17 | Channel 2 Switching | Switch On/Off | 1 Bit | 1.1 switch | CWU |
| 18 | Channel 2 Dimming | Relative dimming | 4 Bit | 3.7 dimming control | CRWU |
| 19 | Channel 2 Dimming | Absolute dimming | 1 Byte | 5.1 percentage (0..100%) | CWU |
| 20 | Channel 2 Switching | Soft switching | 1 Bit | 1.1 switch | CWU |
| 21 | Channel 2 Feedback | Switch On Off feedback | 1 Bit | 1.1 switch | CRTU |
| 22 | Channel 2 Feedback | Brightness feedback | 1 Byte | 5.1 percentage (0..100%) | CRTU |
| 23 | Channel 2 Supplementary | Disable | 1 Bit | 1.1 switch | CRWU |
| 24 | Channel 2 Supplementary | Forced position | 2 Bit | 2.1 switch control | CRWU |
| 25 | Channel 2 Logic | OR | 1 Bit | 1.1 switch | CRWU |
| 25 | Channel 2 Logic | AND | 1 Bit | 1.1 switch | CRWU |
| 26 | Channel 2 Warning | Short circuit / High load | 1 Bit | 1.5 alarm | CRTU |
| 27 | Channel 2 Warning | Over temperature | 1 Bit | 1.5 alarm | CRTU |
| 28 | Channel 2 Warning | Overload | 1 Bit | 1.5 alarm | CRTU |
| 29 | Channel 2 Counter | Operating hours counter (h) | 2 Bytes | 7.7 time (h) | CRTU |
| 30 | Channel 2 Counter | Restart hours counters | 1 Bit | 1.1 switch | CWU |
| 31 | Channel 2 Status | Channel Status | 1 Bit | 1.3 enable | CRTU |
| 32 | Channel 2 Counter | Operating hours counter (s) | 4 Bytes | 13.100 time lag (s) | CRTU |
| 34 | Channel 3 Switching | Switch On/Off | 1 Bit | 1.1 switch | CWU |
| 35 | Channel 3 Dimming | Relative dimming | 4 Bit | 3.7 dimming control | CRWU |
| 36 | Channel 3 Dimming | Absolute dimming | 1 Byte | 5.1 percentage (0..100%) | CWU |
| 37 | Channel 3 Switching | Soft switching | 1 Bit | 1.1 switch | CWU |
| 38 | Channel 3 Feedback | Switch On Off feedback | 1 Bit | 1.1 switch | CRTU |
| 39 | Channel 3 Feedback | Brightness feedback | 1 Byte | 5.1 percentage (0..100%) | CRTU |
| 40 | Channel 3 Supplementary | Disable | 1 Bit | 1.1 switch | CRWU |
| 41 | Channel 3 Supplementary | Forced position | 2 Bit | 2.1 switch control | CRWU |
| 42 | Channel 3 Logic | OR | 1 Bit | 1.1 switch | CRWU |
| 42 | Channel 3 Logic | AND | 1 Bit | 1.1 switch | CRWU |
| 43 | Channel 3 Warning | Short circuit / High load | 1 Bit | 1.1 switch | CRTU |
| 44 | Channel 3 Warning | Over temperature | 1 Bit | 1.1 switch | CRTU |
| 45 | Channel 3 Warning | Overload | 1 Bit | 1.1 switch | CRTU |
| 46 | Channel 3 Counter | Operating hours counter (h) | 2 Bytes | 7.7 time (h) | CRTU |
| 47 | Channel 3 Counter | Restart hours counters | 1 Bit | 1.1 switch | CWU |
| 48 | Channel 3 Status | Channel Status | 1 Bit | 1.3 enable | CRTU |
| 49 | Channel 3 Counter | Operating hours counter (s) | 4 Bytes | 13.100 time lag (s) | CRTU |
| 51 | Channel 4 Switching | Switch On/Off | 1 Bit | 1.1 switch | CWU |
| 52 | Channel 4 Dimming | Relative dimming | 4 Bit | 3.7 dimming control | CRWU |
| 53 | Channel 4 Dimming | Absolute dimming | 1 Byte | 5.1 percentage (0..100%) | CWU |
| 54 | Channel 4 Switching | Soft switching | 1 Bit | 1.1 switch | CWU |
| 55 | Channel 4 Feedback | Switch On Off feedback | 1 Bit | 1.1 switch | CRTU |
| 56 | Channel 4 Feedback | Brightness feedback | 1 Byte | 5.1 percentage (0..100%) | CRTU |
| 57 | Channel 4 Supplementary | Disable | 1 Bit | 1.1 switch | CRWU |
| 58 | Channel 4 Supplementary | Forced position | 2 Bit | 2.1 switch control | CRWU |
| 59 | Channel 4 Logic | OR | 1 Bit | 1.1 switch | CRWU |
| 59 | Channel 4 Logic | AND | 1 Bit | 1.1 switch | CRWU |
| 60 | Channel 4 Warning | Short circuit / High load | 1 Bit | 1.1 switch | CRTU |
| 61 | Channel 4 Warning | Over temperature | 1 Bit | 1.1 switch | CRTU |
| 62 | Channel 4 Warning | Overload | 1 Bit | 1.1 switch | CRTU |
| 63 | Channel 4 Counter | Operating hours counter (h) | 2 Bytes | 7.7 time (h) | CRTU |
| 64 | Channel 4 Counter | Restart hours counters | 1 Bit | 1.1 switch | CWU |
| 65 | Channel 4 Status | Channel Status | 1 Bit | 1.3 enable | CRTU |
| 66 | Channel 4 Counter | Operating hours counter (s) | 4 Bytes | 13.100 time lag (s) | CRTU |
| 68 | Central Switching | Switch On/Off | 1 Bit | 1.1 switch | CWU |
| 69 | Access/Save Scene | Dimming | 1 Byte | 18.1 scene control | CRWU |
Parameters (67)
| Parameter | Type | Default |
|---|---|---|
| Cycle time for sending of feedback objects | list | 5 min. |
| Delay for feedbacks after bus voltage return | list | 5 min. |
| Report operating hours at change | unsignedInt 1…65000 | 1 |
| Feedback cycle time for operating hours counter | list | 5 min. |
| Manual control | list | Yes |
| Blinking rate | list | 1 sec. |
| Type of connected load | list | Universal |
| Minimum brightness (%) | unsignedInt 1…45 | 1 |
| Response when receiving a dimming value | list | Immediate ON |
| Maximum brightness (%) | unsignedInt 50…100 | 100 |
| Switch-ON brightness | list | Minimum brightness |
| Assignment to Central Switching? | list | No |
| Behaviour after bus failure | list | No change |
| Behaviour after restoration of the bus/mains power | list | Same as before bus failure |
| Time for Soft ON (sec.) | unsignedInt 0…60 | 10 |
| Dimming value after Soft ON (%) | unsignedInt 10…100 | 100 |
| Time between Soft ON and Soft OFF | list | Until "Soft Off" telegram |
| Time for Soft OFF (sec.) | unsignedInt 0…60 | 10 |
| Characteristic curve | list | Linear |
| Dimming time between Min. to Max. brigthness (sec.) | unsignedInt 1…60 | 10 |
| 1st area dimming time (sec.) | unsignedInt 1…60 | 10 |
| Brigthness value for the 1st area (%) | unsignedInt 1…100 | 20 |
| 2nd area dimming time (sec.) | unsignedInt 1…60 | 10 |
| Brigthness value for the 2nd area (%) | unsignedInt 1…100 | 60 |
| 3rd area dimming time (sec.) | unsignedInt 1…60 | 10 |
| Sending switch on off feedback | list | No |
| Sending brigthness feedback | list | No |
| Operating hours counter | list | Disable |
| Transmit operating hours cyclically | list | No |
| Send overtemperature error | list | No |
| Send short circuit error | list | No |
| Send overload error | list | No |
| Scene1 activatable by scene number | list | Scene number 1 |
| Storage function for scene1 | list | No |
| Scene1 after download (%) | unsignedInt 0…100 | 10 |
| Scene2 after download (%) | unsignedInt 0…100 | 20 |
| Storage function for scene2 | list | No |
| Scene2 activatable by scene number | list | Scene number 2 |
| Scene3 activatable by scene number | list | Scene number 3 |
| Storage function for scene3 | list | No |
| Scene3 after download (%) | unsignedInt 0…100 | 30 |
| Scene4 after download (%) | unsignedInt 0…100 | 40 |
| Storage function for scene4 | list | No |
| Scene4 activatable by scene number | list | Scene number 4 |
| Scene5 activatable by scene number | list | Scene number 5 |
| Storage function for scene5 | list | No |
| Scene5 after download (%) | unsignedInt 0…100 | 50 |
| Scene6 after download (%) | unsignedInt 0…100 | 60 |
| Storage function for scene6 | list | No |
| Scene6 activatable by scene number | list | Scene number 6 |
| Scene7 activatable by scene number | list | Scene number 7 |
| Storage function for scene7 | list | No |
| Scene7 after download (%) | unsignedInt 0…100 | 70 |
| Scene8 after download (%) | unsignedInt 0…100 | 80 |
| Storage function for scene8 | list | No |
| Scene8 activatable by scene number | list | Scene number 8 |
| Selection of supplementary function | list | No supplementary function |
| Behaviour at the beginning of the disabling function | list | Switch off |
| Behaviour at the end of the disabling function | list | Switch off |
| Brightness for forced position "active, switch on" | list | Minimum brightness |
| Brigthness for forced position "end inactive" | list | No reaction |
| Logic operation function ? | list | No logic function |
| Behaviour when recalling a scene | list | Immediate ON |
| Brigthness for forced position "active, switch off" | list | Switch Off |
| Automatic switch off at minimum brigthness | list | No |
| Cycle time for sending of error and status objects | list | 5 min. |
| Send channel status | list | No |
Version history
| Application | App no | Fingerprint | First seen | Size | File |
|---|---|---|---|---|---|
| Dim-Act-4Ch 1.0 latest | $0305 | 3C63 | 2026-11-25 | 84 KB | Download |
About this file
This is the official ETS product database for the Panasonic 4 Gang Dimming Actuator 250W DM104 (WRKT5414J-XXX), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.
More from Panasonic
- KNX 1-10 V DIMMER CONTROL UNIT 4 GANG GV WRKT5144J5NC
- 2 Gang Dimming Actuator 300W DM102 WRKT5512E-XXX
- KNX POWER SUPPLY UNIT 320 mA WRKT20145NC
- KNX POWER SUPPLY UNIT 640 mA WRKT20275NC
- KNX Power Supply 320mA PS132 WRKT20305NC
- KNX Power Supply 640 mA PS164 WRKT20315NC
- KNX AREA/LINE COUPLER WRKT21015NC
- KNX AREA / LINE COUPLER WRKT21025NC
- KNX SECURE AREA/LINE COUPLER WZ WRKT21035NC
- KNX DALI GATEWAY GV 1/2 Channel WRKT22145/22155NC
- KNX IP INTERFACE WRKT23305NC
- KNX IP ROUTER WRKT23315NC