XY86-KS-WK/XY86-KS-RW-WK
NEXhome · Order number XY86-KS-WK/XY86-KS-RW-WK · K270/K3174
Download .knxprod XY86-KS-WK/XY86-KS-RW-WK 0.1 · 109 KB
Product
| Manufacturer | NEXhome |
|---|---|
| Product name | XY86-KS-WK/XY86-KS-RW-WK |
| Order number | XY86-KS-WK/XY86-KS-RW-WK |
| Hardware | XY86-KS-WK/XY86-KS-RW-WK |
| Medium | Twisted Pair |
| Bus current (mA) | 10 |
| Rail mounted | No |
| Registration | Registered · 2024-01-22 |
| Languages | en-US |
| Catalog entry | M-02A4_H-02A411003221-1_HP-1100-01-1A48_CI-XY86.2DKS.2DWK.2FXY86.2DKS.2DRW.2DWK-1 |
| Fingerprint | 1A48 |
| SHA-256 | 64f31a0a54b8d636d9f88ba2838cbdf1b6c4e71e63d6686eafdd464e1f2278ae |
| First seen | 2026-11-25 |
| Markets | China, Singapore, USA, United Arab Emirates |
Application program: XY86-KS-WK/XY86-KS-RW-WK 0.1
| Application number | $1100 |
|---|---|
| Version | 0.1 |
| Mask version | MV-0705 (7.5) |
| KNX Data Secure | No |
| Minimum ETS version | 5.0 |
| Parameters | 12 |
| Group objects | 19 |
Group objects (19)
| No | Name | Function | Size | DPT | Flags |
|---|---|---|---|---|---|
| 0 | Internal | Temperature Out | 2 Bytes | 9.1 temperature (°C) | CRT |
| 1 | Air Conditioner | Switch Out | 1 Bit | 1.1 switch | CRT |
| 2 | Air Conditioner | Switch In | 1 Bit | 1.1 switch | CWTU |
| 3 | Air Conditioner | Mode Out | 1 Byte | 20.105 HVAC control mode | CRT |
| 4 | Air Conditioner | Mode In | 1 Byte | 20.105 HVAC control mode | CWTU |
| 5 | Air Conditioner | Fan Speed Out | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 6 | Air Conditioner | Fan Speed In | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 7 | Air Conditioner | Set Point Out | 2 Bytes | 9.1 temperature (°C) | CRT |
| 8 | Air Conditioner | Set Point In | 2 Bytes | 9.1 temperature (°C) | CWTU |
| 9 | Floor heating | Switch Out | 1 Bit | 1.1 switch | CRT |
| 10 | Floor heating | Switch In | 1 Bit | 1.1 switch | CWTU |
| 11 | Floor heating | Set Point Out | 2 Bytes | 9.1 temperature (°C) | CRT |
| 12 | Floor heating | Set Point In | 2 Bytes | 9.1 temperature (°C) | CWTU |
| 13 | Floor heating | Feedback Temperture In | 2 Bytes | 9.1 temperature (°C) | CWTU |
| 14 | Floor heating | Control Out | 1 Bit | 1.1 switch | CRT |
| 15 | Ventilation System | Switch Out | 1 Bit | 1.1 switch | CRT |
| 16 | Ventilation System | Switch In | 1 Bit | 1.1 switch | CWTU |
| 17 | Ventilation System | Fan Speed Out | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 18 | Ventilation System | Fan Speed In | 1 Byte | 5.1 percentage (0..100%) | CWTU |
Parameters (9)
| Parameter | Type | Default |
|---|---|---|
| Function | list | Enable |
| State sync | list | Update value only |
| Value for fan speed 1 | unsignedInt 0…255 | 1 |
| Value for fan speed 2 | unsignedInt 0…255 | 2 |
| Value for fan speed 3 | unsignedInt 0…255 | 3 |
| Function | list | Disable |
| Value for fan speed 1 | unsignedInt 0…255 | 85 |
| Value for fan speed 2 | unsignedInt 0…255 | 170 |
| Value for fan speed 3 | unsignedInt 0…255 | 255 |
Version history
| Application | App no | Fingerprint | First seen | Size | File |
|---|---|---|---|---|---|
| XY86-KS-WK/XY86-KS-RW-WK 0.1 latest | $1100 | 1A48 | 2026-11-25 | 109 KB | Download |
About this file
This is the official ETS product database for the NEXhome XY86-KS-WK/XY86-KS-RW-WK (XY86-KS-WK/XY86-KS-RW-WK), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.
More from NEXhome
- EP-KJ-D1/EP-KJ-D2 EP-KJ-D1/EP-KJ-D2
- EP-KJ-L1/EP-KJ-L2 EP-KJ-L1/EP-KJ-L2
- EP-KJ-O1/EP-KJ-O2 EP-KJ-O1/EP-KJ-O2
- K2110/K2188 K2110/K2188
- K270/K3174 K270
- NK-AQ-XA/NK-ES-XC NK-AQ-XA/NK-ES-XC
- TC86-KJR-A3/TC86-KJ-A3 TC86-KJR-A3/TC86-KJ-A3
- TC86-KJR-RW/TC86-KJ-LRW TC86-KJR-RW/TC86-KJ-LRW
- XY86-KS-A/XY86-KSR-A XY-A