KNX Database
Muller Intuitiv M23711X intuis Axino GTB

intuis Axino GTB M23711X

Muller Intuitiv · Order number M23711X · HVAC › Thermostat

Download .knxprod intuis Axino GTB 1.0 · 111 KB

Product

ManufacturerMuller Intuitiv
Product nameintuis Axino GTB
Order numberM23711X
Hardwareintuis Axino GTB
MediumTwisted Pair
Bus current (mA)3
Rail mountedNo
RegistrationRegistered · 2026-05-26
Languagesen-US, fr-FR
Catalog entryM-0308_H-intuis.20Axino.20GTB-256_HP-0001-10-E477_CI-M23711X-1
FingerprintE477
SHA-256df15689afa677667ce77786b4003bd031e678cfc2988d8a622596d1f6f1317bc
First seen2026-11-25
MarketsFrance

Application program: intuis Axino GTB 1.0

Application number$0001
Version1.0
Mask versionMV-07B0 (System B)
KNX Data SecureNo
Minimum ETS version5.0
Parameters27
Group objects22
Group objects (22)
NoNameFunctionSizeDPTFlags
1Current measured temperature (internal temperature sensor)Value2 BytesDPT.9CRT
2Monitored modeState1 ByteDPT.20CRT
3Setpoint followedValue2 BytesDPT.9CRT
4Offset monitoredValue2 BytesDPT.9CRT
5Window statusState1 BitDPT.1CRT
6Open window detection activation settingSwitch1 BitDPT.1CRWT
7Open window detection type settingSwitch1 BitDPT.1CRWT
8Presence detection statusState1 BitDPT.1CRT
9Product consumptionValue4 BytesDPT.13CRT
10Product powerValue4 BytesDPT.14CRT
11Cyclic ratioValue1 ByteDPT.5CRT
12ModeSetpoint1 ByteDPT.20CW
13Comfort setpointSetpoint2 BytesDPT.9CW
14Auto temperatureSetpoint2 BytesDPT.9CW
15Economy setpointSetpoint2 BytesDPT.9CW
16Frost protection setpointSetpoint2 BytesDPT.9CW
17Override setpoint range limitationSetpoint2 BytesDPT.9CW
18Load sheddingSwitch1 BitDPT.1CW
19Reset offset userReset1 BitDPT.1CW
20Standby/On button actionSwitch1 BitDPT.1CRWT
21Setting offset actionIncrease/decrease1 BitDPT.1CRWT
22Current temperature measured (external temperature sensor)Setpoint2 BytesDPT.9CW
Parameters (27)
ParameterTypeDefault
Device friendly nametextintuis Axino GTB
Send indicationlistEnabled
Description size highunsignedInt 0…2550
Description size lowunsignedInt 0…2550
PAR_DPT_OBJECT_1unsignedInt 0…2559
PAR_DPT_OBJECT_2unsignedInt 0…25532
PAR_DPT_OBJECT_3unsignedInt 0…2559
PAR_DPT_OBJECT_4unsignedInt 0…2559
PAR_DPT_OBJECT_5unsignedInt 0…2551
PAR_DPT_OBJECT_6unsignedInt 0…2551
PAR_DPT_OBJECT_7unsignedInt 0…2551
PAR_DPT_OBJECT_8unsignedInt 0…2551
PAR_DPT_OBJECT_9unsignedInt 0…25513
PAR_DPT_OBJECT_10unsignedInt 0…25514
PAR_DPT_OBJECT_11unsignedInt 0…2555
PAR_DPT_OBJECT_12unsignedInt 0…25532
PAR_DPT_OBJECT_13unsignedInt 0…2559
PAR_DPT_OBJECT_14unsignedInt 0…2559
PAR_DPT_OBJECT_15unsignedInt 0…2559
PAR_DPT_OBJECT_16unsignedInt 0…2559
PAR_DPT_OBJECT_17unsignedInt 0…2559
PAR_DPT_OBJECT_18unsignedInt 0…2551
PAR_DPT_OBJECT_19unsignedInt 0…2551
PAR_DPT_OBJECT_20unsignedInt 0…2551
PAR_DPT_OBJECT_21unsignedInt 0…2551
PAR_DPT_OBJECT_22unsignedInt 0…2559
PID_HARDWARE_TYPE_PARAMETERlist

Version history

ApplicationApp noFingerprintFirst seenSizeFile
intuis Axino GTB 1.0 latest$0001E4772026-11-25111 KBDownload

About this file

This is the official ETS product database for the Muller Intuitiv intuis Axino GTB (M23711X), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.