CTS-06
Module Electronic · Order number CTS-06 · Controllers › Temperature controllers
Download .knxprod CTS-01/06 1.1 · 124 KB
Product
| Manufacturer | Module Electronic |
|---|---|
| Product name | CTS-06 |
| Order number | CTS-06 |
| Hardware | CTS-06 |
| Medium | Twisted Pair |
| Bus current (mA) | 10 |
| Rail mounted | No |
| Registration | Certified · 2021-10-25 |
| Languages | ru-RU, en-US |
| Catalog entry | M-01C6_H-01C603060001-64_HP-0306-11-0FBC_CI-CTS.2D06-1 |
| Fingerprint | 0FBC |
| SHA-256 | 02f00cbab206ecbf83390fb0a035c43d55274ce13881524c340215cbb9267462 |
| First seen | 2026-11-25 |
| Markets | 59 markets |
Application program: CTS-01/06 1.1
| Application number | $0306 |
|---|---|
| Version | 1.1 |
| Mask version | MV-07B0 (System B) |
| KNX Data Secure | No |
| Minimum ETS version | 5.0 |
| Parameters | 175 |
| Group objects | 90 |
Group objects (90)
| No | Name | Function | Size | DPT | Flags |
|---|---|---|---|---|---|
| 1 | Channel 1 | Current temperature | 2 Bytes | 9.1 temperature (°C) | CRT |
| 2 | Channel 2 | Current temperature | 2 Bytes | 9.1 temperature (°C) | CRT |
| 3 | Channel 3 | Current temperature | 2 Bytes | 9.1 temperature (°C) | CRT |
| 4 | Channel 4 | Current temperature | 2 Bytes | 9.1 temperature (°C) | CRT |
| 5 | Channel 5 | Current temperature | 2 Bytes | 9.1 temperature (°C) | CRT |
| 6 | Channel 6 | Current temperature | 2 Bytes | 9.1 temperature (°C) | CRT |
| 7 | Channel 1 | External temperature | 2 Bytes | 9.1 temperature (°C) | CWU |
| 8 | Channel 2 | External temperature | 2 Bytes | 9.1 temperature (°C) | CWU |
| 9 | Channel 3 | External temperature | 2 Bytes | 9.1 temperature (°C) | CWU |
| 10 | Channel 4 | External temperature | 2 Bytes | 9.1 temperature (°C) | CWU |
| 11 | Channel 5 | External temperature | 2 Bytes | 9.1 temperature (°C) | CWU |
| 12 | Channel 6 | External temperature | 2 Bytes | 9.1 temperature (°C) | CWU |
| 13 | Channel 1 | Comfort setpoint | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 14 | Channel 2 | Comfort setpoint | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 15 | Channel 3 | Comfort setpoint | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 16 | Channel 4 | Comfort setpoint | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 17 | Channel 5 | Comfort setpoint | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 18 | Channel 6 | Comfort setpoint | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 19 | Channel 1 | Actual setpoint | 2 Bytes | 9.1 temperature (°C) | CRT |
| 20 | Channel 2 | Actual setpoint | 2 Bytes | 9.1 temperature (°C) | CRT |
| 21 | Channel 3 | Actual setpoint | 2 Bytes | 9.1 temperature (°C) | CRT |
| 22 | Channel 4 | Actual setpoint | 2 Bytes | 9.1 temperature (°C) | CRT |
| 23 | Channel 5 | Actual setpoint | 2 Bytes | 9.1 temperature (°C) | CRT |
| 24 | Channel 6 | Actual setpoint | 2 Bytes | 9.1 temperature (°C) | CRT |
| 25 | Channel 1 | Comfort mode | 1 Bit | 1.1 switch | CRWTU |
| 26 | Channel 2 | Comfort mode | 1 Bit | 1.1 switch | CRWTU |
| 27 | Channel 3 | Comfort mode | 1 Bit | 1.1 switch | CRWTU |
| 28 | Channel 4 | Comfort mode | 1 Bit | 1.1 switch | CRWTU |
| 29 | Channel 5 | Comfort mode | 1 Bit | 1.1 switch | CRWTU |
| 30 | Channel 6 | Comfort mode | 1 Bit | 1.1 switch | CRWTU |
| 31 | Channel 1 | Standby mode | 1 Bit | 1.1 switch | CRWTU |
| 32 | Channel 2 | Standby mode | 1 Bit | 1.1 switch | CRWTU |
| 33 | Channel 3 | Standby mode | 1 Bit | 1.1 switch | CRWTU |
| 34 | Channel 4 | Standby mode | 1 Bit | 1.1 switch | CRWTU |
| 35 | Channel 5 | Standby mode | 1 Bit | 1.1 switch | CRWTU |
| 36 | Channel 6 | Standby mode | 1 Bit | 1.1 switch | CRWTU |
| 37 | Channel 1 | Economy mode | 1 Bit | 1.1 switch | CRWTU |
| 38 | Channel 2 | Economy mode | 1 Bit | 1.1 switch | CRWTU |
| 39 | Channel 3 | Economy mode | 1 Bit | 1.1 switch | CRWTU |
| 40 | Channel 4 | Economy mode | 1 Bit | 1.1 switch | CRWTU |
| 41 | Channel 5 | Economy mode | 1 Bit | 1.1 switch | CRWTU |
| 42 | Channel 6 | Economy mode | 1 Bit | 1.1 switch | CRWTU |
| 43 | Channel 1 | HVAC mode | 1 Byte | 20.102 HVAC mode | CRWTU |
| 44 | Channel 2 | HVAC mode | 1 Byte | 20.102 HVAC mode | CRWTU |
| 45 | Channel 3 | HVAC mode | 1 Byte | 20.102 HVAC mode | CRWTU |
| 46 | Channel 4 | HVAC mode | 1 Byte | 20.102 HVAC mode | CRWTU |
| 47 | Channel 5 | HVAC mode | 1 Byte | 20.102 HVAC mode | CRWTU |
| 48 | Channel 6 | HVAC mode | 1 Byte | 20.102 HVAC mode | CRWTU |
| 49 | Channel 1 | Cooler/heater | 1 Bit | 1.100 cooling/heating | CRWTU |
| 50 | Channel 2 | Cooler/heater | 1 Bit | 1.100 cooling/heating | CRWTU |
| 51 | Channel 3 | Cooler/heater | 1 Bit | 1.100 cooling/heating | CRWTU |
| 52 | Channel 4 | Cooler/heater | 1 Bit | 1.100 cooling/heating | CRWTU |
| 53 | Channel 5 | Cooler/heater | 1 Bit | 1.100 cooling/heating | CRWTU |
| 54 | Channel 6 | Cooler/heater | 1 Bit | 1.100 cooling/heating | CRWTU |
| 55 | Channel 1 | Controller on/off | 1 Bit | 1.1 switch | CRWTU |
| 56 | Channel 2 | Controller on/off | 1 Bit | 1.1 switch | CRWTU |
| 57 | Channel 3 | Controller on/off | 1 Bit | 1.1 switch | CRWTU |
| 58 | Channel 4 | Controller on/off | 1 Bit | 1.1 switch | CRWTU |
| 59 | Channel 5 | Controller on/off | 1 Bit | 1.1 switch | CRWTU |
| 60 | Channel 6 | Controller on/off | 1 Bit | 1.1 switch | CRWTU |
| 61 | Channel 1 | Actuating command (on/off) | 1 Bit | 1.1 switch | CRT |
| 62 | Channel 2 | Actuating command (on/off) | 1 Bit | 1.1 switch | CRT |
| 63 | Channel 3 | Actuating command (on/off) | 1 Bit | 1.1 switch | CRT |
| 64 | Channel 4 | Actuating command (on/off) | 1 Bit | 1.1 switch | CRT |
| 65 | Channel 5 | Actuating command (on/off) | 1 Bit | 1.1 switch | CRT |
| 66 | Channel 6 | Actuating command (on/off) | 1 Bit | 1.1 switch | CRT |
| 67 | Channel 1 | Actuating command (%) | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 68 | Channel 2 | Actuating command (%) | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 69 | Channel 3 | Actuating command (%) | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 70 | Channel 4 | Actuating command (%) | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 71 | Channel 5 | Actuating command (%) | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 72 | Channel 6 | Actuating command (%) | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 73 | Channel 1 | Sensor alarm | 1 Bit | 1.5 alarm | CRT |
| 74 | Channel 2 | Sensor alarm | 1 Bit | 1.5 alarm | CRT |
| 75 | Channel 3 | Sensor alarm | 1 Bit | 1.5 alarm | CRT |
| 76 | Channel 4 | Sensor alarm | 1 Bit | 1.5 alarm | CRT |
| 77 | Channel 5 | Sensor alarm | 1 Bit | 1.5 alarm | CRT |
| 78 | Channel 6 | Sensor alarm | 1 Bit | 1.5 alarm | CRT |
| 79 | Channel 1 | Frost alarm | 1 Bit | 1.5 alarm | CRT |
| 80 | Channel 2 | Frost alarm | 1 Bit | 1.5 alarm | CRT |
| 81 | Channel 3 | Frost alarm | 1 Bit | 1.5 alarm | CRT |
| 82 | Channel 4 | Frost alarm | 1 Bit | 1.5 alarm | CRT |
| 83 | Channel 5 | Frost alarm | 1 Bit | 1.5 alarm | CRT |
| 84 | Channel 6 | Frost alarm | 1 Bit | 1.5 alarm | CRT |
| 85 | Channel 1 | Heat alarm | 1 Bit | 1.5 alarm | CRT |
| 86 | Channel 2 | Heat alarm | 1 Bit | 1.5 alarm | CRT |
| 87 | Channel 3 | Heat alarm | 1 Bit | 1.5 alarm | CRT |
| 88 | Channel 4 | Heat alarm | 1 Bit | 1.5 alarm | CRT |
| 89 | Channel 5 | Heat alarm | 1 Bit | 1.5 alarm | CRT |
| 90 | Channel 6 | Heat alarm | 1 Bit | 1.5 alarm | CRT |
Parameters (30)
| Parameter | Type | Default |
|---|---|---|
| Sensor failure alarm | list | Don't send |
| Actuating command when sensor failure | list | Don't change |
| PWM period (minutes) | unsignedInt 1…255 | 1 |
| Integration period (minutes) | unsignedInt 0…255 | 60 |
| Action on reset | list | Restore previous mode |
| Heating system | list | Split unit (4 °C, 60 minutes) |
| Minimum actuating value (%) | unsignedInt 0…100 | 0 |
| - when temperature < (°C) | signedInt -3…15 | 0 |
| Controller direction | list | Normal |
| "Standby" mode offset (°C) | unsignedInt 0…25 | 0 |
| "Economy" mode offset (°C) | unsignedInt 0…25 | 0 |
| Repeat actuating command periodically every (minutes, 0 - don't repeat) | unsignedInt 0…60 | 0 |
| Device model | list | CTS-01 |
| Channel activity | list | Inactive |
| - on change of (* 0,1 °C, 0 - don't send) | unsignedInt 0…20 | 0 |
| - when temperature > (°C) | unsignedInt 25…50 | 50 |
| Controller mode | list | 2-points |
| Controller type | list | Heater |
| "Comfort" mode setpoint (°C) | float 15…35 | 25 |
| - every (minutes, 0 - don't send) | unsignedInt 0…60 | 0 |
| Actuating value when sensor failure (%, -1 = don't change) | signedInt -1…100 | -1 |
| Hysteresis (* 0,1 °C) | unsignedInt 0…50 | 0 |
| Sensor | list | Internal |
| Cooling system | list | Split unit (4 °C, 60 minutes) |
| Heat/frost alarms | list | Don't send |
| Maximum actuating value (%) | unsignedInt 0…100 | 100 |
| Proportional range (°C) | unsignedInt 1…255 | 4 |
| Temperature control | list | Off |
| Internal sensor correction (* 0,1 °C) | signedInt -100…100 | 0 |
| Sensor alarm after no temperature telegrams during (minutes, 0 - don't check) | unsignedInt 0…60 | 0 |
Version history
| Application | App no | Fingerprint | First seen | Size | File |
|---|---|---|---|---|---|
| CTS-01/06 1.1 latest | $0306 | 0FBC | 2026-11-25 | 124 KB | Download |
About this file
This is the official ETS product database for the Module Electronic CTS-06 (CTS-06), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.