Weather station Home SCN-WS3HW.01
MDT technologies GmbH · Order number SCN-WS3HW.01 · Weather sensors › Weather station Home
Weather station, Facade control
Download .knxprod Weather station Home 1.3 · 110 KB
Product
| Manufacturer | MDT technologies GmbH |
|---|---|
| Product name | Weather station Home |
| Order number | SCN-WS3HW.01 |
| Product text | SCN-WS3HW.01 Weather station Home |
| Hardware | Wetterstation Home |
| Medium | Twisted Pair |
| Bus current (mA) | 10 |
| Rail mounted | No |
| Registration | Certified · 2012-06-01 |
| Languages | de-DE, en-US, es-ES, fr-FR |
| Catalog entry | M-0083_H-77-1_HP-004D-13-2B44_CI-SCN.2DWS3HW.2E01-1 |
| Fingerprint | 2B44 |
| SHA-256 | 125e4f676c88f815238308256cfb9c3427844d7056de78275902e93e3d10a2b0 |
| First seen | 2026-11-25 |
| Markets | 69 markets |
Application program: Weather station Home 1.3
| Application number | $004D |
|---|---|
| Version | 1.3 |
| Mask version | MV-0701 (7.1) |
| KNX Data Secure | No |
| Minimum ETS version | 3.0d |
| Parameters | 269 |
| Group objects | 79 |
Group objects (79)
| No | Name | Function | Size | DPT | Flags |
|---|---|---|---|---|---|
| 0 | Brightness East | Send measured value | 2 Bytes | 9.4 lux (Lux) | CRT |
| 1 | Brightness East | Threshold value 1 | 1 Bit | 1.1 switch | CRT |
| 2 | Brightness East | Threshold value 2 | 1 Bit | 1.1 switch | CRT |
| 3 | Brightness East | Threshold value 1 upper limit | 2 Bytes | 9.4 lux (Lux) | CWT |
| 4 | Brightness East | Threshold value 1 lower limit | 2 Bytes | 9.4 lux (Lux) | CWT |
| 5 | Brightness East | Lock object: Threshold values | 1 Bit | 1.3 enable | CWT |
| 6 | Facade East | Automatic 1 ON | 1 Bit | 1.1 switch | CRT |
| 6 | Facade East | Send scene | 1 Byte | CRT | |
| 6 | Facade East | Send position of blinds | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 6 | Facade East | Send position of shutter | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 7 | Facade East | Automatic 2 ON | 1 Bit | 1.1 switch | CRT |
| 7 | Facade East | Send position of slats | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 8 | Facade East | Lock object: Facade | 1 Bit | 1.3 enable | CWT |
| 9 | Facade East | Teach-in position 1 | 1 Bit | 1.3 enable | CWT |
| 10 | Facade East | Teach-in position 2 | 1 Bit | 1.3 enable | CWT |
| 11 | Facade East | Status of shutter for Teach-in | 1 Byte | 5.1 percentage (0..100%) | CWT |
| 11 | Facade East | Status of blinds for Teach-in | 1 Byte | 5.1 percentage (0..100%) | CWT |
| 12 | Facade East | Status of slats for Teach-in | 1 Byte | 5.1 percentage (0..100%) | CWT |
| 13 | Facade East | External temperature - Input | 2 Bytes | 9.1 temperature (°C) | CWT |
| 14 | Dummy | 1 Byte | |||
| 15 | Dummy | 1 Byte | |||
| 16 | Dummy | 1 Byte | |||
| 17 | Brightness South | Send measured value | 2 Bytes | 9.4 lux (Lux) | CRT |
| 18 | Brightness South | Threshold value 1 | 1 Bit | 1.1 switch | CRT |
| 19 | Brightness South | Threshold value 2 | 1 Bit | 1.1 switch | CRT |
| 20 | Brightness South | Threshold value 1 upper limit | 2 Bytes | 9.4 lux (Lux) | CWT |
| 21 | Brightness South | Threshold value 1 lower limit | 2 Bytes | 9.4 lux (Lux) | CWT |
| 22 | Brightness South | Lock object: Threshold values | 1 Bit | 1.3 enable | CWT |
| 23 | Facade South | Automatic 1 ON | 1 Bit | 1.1 switch | CRT |
| 23 | Facade South | Send scene | 1 Byte | CRT | |
| 23 | Facade South | Send position of shutter | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 23 | Facade South | Send position of blinds | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 24 | Facade South | Automatic 2 ON | 1 Bit | 1.1 switch | CRT |
| 24 | Facade South | Send position of slats | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 25 | Facade South | Lock object: Facade | 1 Bit | 1.3 enable | CWT |
| 26 | Facade South | Teach-in position 1 | 1 Bit | 1.3 enable | CWT |
| 27 | Facade South | Teach-in position 2 | 1 Bit | 1.3 enable | CWT |
| 28 | Facade South | Status of shutter for Teach-in | 1 Byte | 5.1 percentage (0..100%) | CWT |
| 28 | Facade South | Status of blinds for Teach-in | 1 Byte | 5.1 percentage (0..100%) | CWT |
| 29 | Facade South | Status of slats for Teach-in | 1 Byte | 5.1 percentage (0..100%) | CWT |
| 30 | Facade South | External temperature - Input | 2 Bytes | 9.1 temperature (°C) | CWT |
| 31 | Dummy | 1 Byte | |||
| 32 | Dummy | 1 Byte | |||
| 33 | Dummy | 1 Byte | |||
| 34 | Brightness West | Send measured value | 2 Bytes | 9.4 lux (Lux) | CRT |
| 35 | Brightness West | Threshold value 1 | 1 Bit | 1.1 switch | CRT |
| 36 | Brightness West | Threshold value 2 | 1 Bit | 1.1 switch | CRT |
| 37 | Brightness West | Threshold value 1 upper limit | 2 Bytes | 9.4 lux (Lux) | CWT |
| 38 | Brightness West | Threshold value 1 lower limit | 2 Bytes | 9.4 lux (Lux) | CWT |
| 39 | Brightness West | Lock object: Threshold values | 1 Bit | 1.3 enable | CWT |
| 40 | Facade West | Automatic 1 ON | 1 Bit | 1.1 switch | CRT |
| 40 | Facade West | Send scene | 1 Byte | CRT | |
| 40 | Facade West | Send position of shutter | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 40 | Facade West | Send position of blinds | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 41 | Facade West | Automatic 2 ON | 1 Bit | 1.1 switch | CRT |
| 41 | Facade West | Send position of slats | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 42 | Facade West | Lock object: Facade | 1 Bit | 1.3 enable | CWT |
| 43 | Facade West | Teach-in position 1 | 1 Bit | 1.3 enable | CWT |
| 44 | Facade West | Teach-in position 2 | 1 Bit | 1.3 enable | CWT |
| 45 | Facade West | Status of shutter for Teach-in | 1 Byte | 5.1 percentage (0..100%) | CWT |
| 45 | Facade West | Status of blinds for Teach-in | 1 Byte | 5.1 percentage (0..100%) | CWT |
| 46 | Facade West | Status of slats for Teach-in | 1 Byte | 5.1 percentage (0..100%) | CWT |
| 47 | Facade West | External temperature - Input | 2 Bytes | 9.1 temperature (°C) | CWT |
| 48 | Dummy | 1 Byte | |||
| 49 | Dummy | 1 Byte | |||
| 50 | Dummy | 1 Byte | |||
| 51 | Twilight | Send measured value | 2 Bytes | 9.4 lux (Lux) | CRT |
| 52 | Twilight | Switchover Day/Night | 1 Bit | 1.1 switch | CRT |
| 53 | Wind | Threshold value 1 | 1 Bit | 1.1 switch | CRT |
| 54 | Wind | Send measured value | 2 Bytes | 9.5 speed (m/s) | CRT |
| 55 | Temperature | Send measured value | 2 Bytes | 9.1 temperature (°C) | CRT |
| 56 | Temperature | Threshold value 1 | 1 Bit | 1.1 switch | CRT |
| 57 | Temperature | Threshold value 2 | 1 Bit | 1.1 switch | CRT |
| 58 | In operation | Status | 1 Bit | 1.1 switch | CRT |
| 59 | Twilight | Blinds/Shutter Up/Down | 1 Bit | 1.8 up/down | CRT |
| 60 | Twilight | Lock object: Blinds/Shutter Up/Down | 1 Bit | 1.3 enable | CWT |
| 61 | Wind | Threshold value 2 | 1 Bit | 1.1 switch | CRT |
| 62 | Dummy | 1 Byte | |||
| 63 | Dummy | 1 Byte |
Parameters (79)
| Parameter | Type | Default |
|---|---|---|
| Startup time | list | 1 s |
| Limitation of telegrams | list | not active |
| Number of telegrams per 10 seconds | unsignedInt 0…255 | 15 |
| Send "In-operation" cyclically | list | not active |
| Behavior after programming | list | hold Teach-in/saved values |
| Brightness sensor East | list | active |
| Brightness sensor South | list | active |
| Brightness sensor West | list | active |
| Twilight sensor | list | active |
| Wind sensor | list | active |
| Temperature sensor | list | active |
| Operating mode | list | normal operation |
| Dummy | list | not active |
| Send measured value | list | on change |
| Send on change of ... | list | 10 % |
| Send cyclically every … | list | 5 min |
| Threshold value 1 | list | not active |
| Threshold value 2 | list | not active |
| Facade control East | list | not active |
| Upper limit | unsignedInt 1…99 | 35 |
| Minimum time of exceedance | list | 10 min |
| Lower limit | unsignedInt 1…99 | 30 |
| Minimum time of undercutting | list | 30 min |
| Threshold value adjustable | list | only via parameter |
| Value when exceeded | list | ON |
| Value when undercut | list | OFF |
| Send cyclically every ... | list | not active |
| Lock object: Threshold value 1 | list | not active |
| Upper limit | unsignedInt 1…99 | 40 |
| Lower limit | unsignedInt 1…99 | 35 |
| Lock object: threshold value 2 | list | not active |
| dummyDptSide(0) | list | not active |
| Action on exceeding threshold value 1 | list | Automatic position 1 ON |
| Action on undercutting threshold value 1 | list | Automatic position 1 OFF |
| Action on exceeding threshold value 2 | list | Automatic position 2 ON |
| Function | list | absolute height position |
| Action on exceeding threshold value 1 | list | send scene |
| Scene number | list | 1 |
| Action on undercutting threshold value 1 | list | send scene |
| Scene number | list | 2 |
| Action on exceeding threshold value 2 | list | not active |
| Scene number | list | 3 |
| Action on exceeding threshold value 1 | list | not active |
| Absolute height position | list | 0 % |
| Position 1 | list | Teach-in is not used |
| Action on undercutting threshold value 1 | list | not active |
| Position 2 | list | Teach-in is not used |
| Absolute position of slats | list | 0 % |
| Function with temperature influence | list | not active |
| Action only if temperature greater ... | list | 25 °C |
| Lock object | list | not active |
| Facade control South | list | not active |
| Upper limit | unsignedInt 1…99 | 45 |
| Lower limit | unsignedInt 1…99 | 40 |
| Facade control West | list | not active |
| Send cyclically every ... | list | 1 min |
| Day/Night object | list | not active |
| "Day" if greater than … | list | 100 |
| "Night" if less than … | list | 10 |
| Telegramm senden bei Tag | list | not active |
| Telegramm senden bei Nacht | list | not active |
| Objekt for blinds/shutter control | list | not active |
| Delay after change to "Day" | list | not active |
| Delay after change to "Night" | list | not active |
| Upper limit | unsignedInt 1…240 | 40 |
| Minimum time of exceedance | list | 5 min |
| Lower limit | unsignedInt 1…240 | 20 |
| This setting only applies to hardware from version R1.8 | text | <- TIP |
| Upper limit | unsignedInt 1…240 | 80 |
| Lower limit | unsignedInt 1…240 | 60 |
| Send on change of ... | list | 1,0 K |
| Calibration value for sensor (value x 0,1) | signedInt -50…50 | 0 |
| Send cyclically every ... | list | 5 min |
| Upper limit | signedInt -30…50 | 6 |
| Value when exceeded | list | OFF |
| Lower limit | signedInt -30…50 | 4 |
| Value when undercut | list | ON |
| Upper limit | signedInt -30…50 | 40 |
| Lower limit | signedInt -30…50 | 35 |
Version history
| Application | App no | Fingerprint | First seen | Size | File |
|---|---|---|---|---|---|
| Weather station Home 1.3 latest | $004D | 2B44 | 2026-11-25 | 110 KB | Download |
About this file
This is the official ETS product database for the MDT technologies GmbH Weather station Home (SCN-WS3HW.01), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.
More from MDT technologies GmbH
- SCN-DTSEN1.01 Twilight / Temperature Sensor SCN-DTSEN1.01
- SCN-LSEN1.01 Leakage Sensor SCN-LSEN1.01
- SCN-RS1R.01 Rain sensor SCN-RS1R.01
- Analog I/O 2fold, flush mounted AIO-0210V.01
- Analog I/O 4fold, MDRC AIO-0410V.01
- AKD-0103.01 Dimming actuator 1-f, 4TE, 230VAC,600W AKD-0103.01
- AKD-0201.01 Dimming actuator 2-f, 4TE, 230VAC,250W AKD-0201.01
- AKD-0201.02 Dimming Actuator 2-fold AKD-0201.02
- AKD-0203.01 Dimming actuator 2-f, 8TE, 230VAC,600W AKD-0203.01
- AKD-0224V.01 LED Controller 2 channel AKD-0224V.01
- AKD-0224V.02 LED Controler 2 Ch AKD-0224V.02
- AKD-0230CC.02 LED Controller CC/CV 30 W / 230 V 2-channel AKD-0230CC.02