KNX RF+ Shutter Actuator 1-fold, UP RF-JAL1UP.01
MDT technologies GmbH · Order number RF-JAL1UP.01 · KNX RF+ Device › KNX RF+ Shutter Actuator
Flush mounted 230VAC, 10A, motors until 300W
Download .knxprod Blinds and Shutters 1-fold 1.0 · 137 KB
Product
| Manufacturer | MDT technologies GmbH |
|---|---|
| Product name | KNX RF+ Shutter Actuator 1-fold, UP |
| Order number | RF-JAL1UP.01 |
| Hardware | KNX RF+ Funk Jalousieaktor 1-fach, UP |
| Medium | KNX RF |
| Rail mounted | No |
| Device kind | RFRetransmitter |
| Registration | Certified · 2015-09-17 |
| Languages | de-DE, en-US, es-ES, fr-FR |
| Catalog entry | M-0083_H-2.2E46-2_HP-00EC-10-3C3F_CI-RF.2DJAL1UP.2E01-1 |
| Fingerprint | 3C3F |
| SHA-256 | 67d5722cbc14fa18a489fc5c590e1164c9634a8c5efa91d8d442a8e56548ab73 |
| First seen | 2026-11-25 |
| Markets | 69 markets |
Application program: Blinds and Shutters 1-fold 1.0
| Application number | $00EC |
|---|---|
| Version | 1.0 |
| Mask version | MV-2705 (RF 7.5) |
| KNX Data Secure | No |
| Minimum ETS version | 5.0 |
| Parameters | 138 |
| Group objects | 38 |
Group objects (38)
| No | Name | Function | Size | DPT | Flags |
|---|---|---|---|---|---|
| 0 | all Channels | Blinds up/down | 1 Bit | 1.8 up/down | CW |
| 1 | all Channels | Slats adjustment /Stop | 1 Bit | 1.9 open/close | CW |
| 2 | all Channels | Stop | 1 Bit | 1.1 switch | CW |
| 3 | all Channels | Absolute position | 1 Byte | 5.1 percentage (0..100%) | CW |
| 4 | all Channels | Absolute position of slats | 1 Byte | 5.1 percentage (0..100%) | CW |
| 5 | Automatic A | Automatic position 1 | 1 Bit | 1.1 switch | CW |
| 6 | Automatic A | Automatic position 2 | 1 Bit | 1.1 switch | CW |
| 7 | Automatic A | Automatic position 3 | 1 Bit | 1.1 switch | CW |
| 8 | Automatic A | Automatic position 4 | 1 Bit | 1.1 switch | CW |
| 9 | Automatic B | Automatic position 1 | 1 Bit | 1.1 switch | CW |
| 10 | Automatic B | Automatic position 2 | 1 Bit | 1.1 switch | CW |
| 11 | Automatic B | Automatic position 3 | 1 Bit | 1.1 switch | CW |
| 12 | Automatic B | Automatic position 4 | 1 Bit | 1.1 switch | CW |
| 13 | Channel A | Shutter up/down | 1 Bit | 1.8 up/down | CW |
| 13 | Channel A | Blinds up/down | 1 Bit | 1.8 up/down | CW |
| 14 | Channel A | Slats adjustment /Stop | 1 Bit | 1.9 open/close | CW |
| 14 | Channel A | Short term operation | 1 Bit | 1.9 open/close | CW |
| 15 | Channel A | Stop | 1 Bit | 1.1 switch | CW |
| 16 | Channel A | Scene | 1 Byte | 17.1 scene number | CW |
| 17 | Channel A | Status current direction | 1 Bit | 1.8 up/down | CRT |
| 17 | Channel A | Status of movement | 1 Bit | 1.8 up/down | CRT |
| 17 | Channel A | Status of movement | 1 Bit | 1.10 start/stop | CRT |
| 18 | Channel A | Absolute position | 1 Byte | 5.1 percentage (0..100%) | CW |
| 19 | Channel A | Absolute position of slats | 1 Byte | 5.1 percentage (0..100%) | CW |
| 20 | Channel A | Status current position | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 21 | Channel A | Status cur. position of slats | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 22 | Channel A | Current position valid | 1 Bit | 1.2 boolean | CRT |
| 23 | Channel A | Start driving to reference | 1 Bit | 1.1 switch | CW |
| 24 | Channel A | Drive to limitation | 1 Bit | 1.8 up/down | CW |
| 24 | Channel A | Drive to position | 1 Bit | 1.1 switch | CW |
| 25 | Channel A | Status upper Position | 1 Bit | 1.11 state | CRT |
| 26 | Channel A | Status lower Position | 1 Bit | 1.11 state | CRT |
| 27 | Channel A | Block absolute position mode | 1 Bit | 1.3 enable | CW |
| 28 | Channel A | Block universal mode | 1 Bit | 1.3 enable | CW |
| 29 | Channel A | Wind alarm | 1 Bit | 1.5 alarm | CW |
| 30 | Channel A | Rain alarm | 1 Bit | 1.5 alarm | CW |
| 31 | Channel A | Frost alarm | 1 Bit | 1.5 alarm | CW |
| 32 | Channel A | Block | 1 Bit | 1.3 enable | CW |
Parameters (113)
| Parameter | Type | Default |
|---|---|---|
| Channel A | list | Blinds |
| Minimale Verfahrzeit (ms) | unsignedInt 1…10000 | 50 |
| ebm | list | Shutter |
| Time for height adjustment (sec) | unsignedInt 0…10000 | 45 |
| Step time for slat adjustment (ms) | unsignedInt 50…1000 | 200 |
| Lamellenverstellzeit (ms) | unsignedInt 1…1 | 1 |
| Slat adjustment time (ms) | unsignedInt 10…10000 | 1200 |
| Pause at change of direction (ms) | unsignedInt 100…1000 | 1000 |
| Switch-on delay motor (ms) | unsignedInt 0…255 | 200 |
| Switch-off delay motor (ms) | unsignedInt 0…255 | 200 |
| Extension of movement time | list | 5% |
| Position of slats at end of driving | list | 100% |
| Absolut enable 0 | unsignedInt 0…255 | 4 |
| Automaitk enable 1 | unsignedInt 0…255 | 0 |
| Objects for absolute position | list | not active |
| Reaction after driving to reference | list | no reaction |
| Function object number 24 | list | not active |
| Lower limit | list | 0% |
| Upper limit | list | 100% |
| Aktion Sperren | list | no action |
| Scene | list | not active |
| Automatic function | list | not active |
| Alarm and block functions | list | not active |
| Alarmobjekte | unsignedInt 255…255 | 255 |
| Alarmobjekte | unsignedInt 0…7 | 0 |
| Kogikcoperation | unsignedInt 2…2 | 2 |
| invertMask | unsignedInt 0…65535 | 0 |
| inputMask | unsignedInt 0…65535 | 15 |
| Order of alarms | list | Wind, Rain, Frost, Block |
| bitMask of input | unsignedInt 0…65535 | 8 |
| bitMask of input | unsignedInt 0…65535 | 4 |
| bitMask of input | unsignedInt 0…65535 | 2 |
| bitMask of input | unsignedInt 0…65535 | 1 |
| off Action Mask | unsignedInt 0…65535 | 14 |
| Action at reset of alarms / block | list | no action |
| Action at reset of alarms | list | no action |
| Wind alarm | list | not active |
| Cycle Time (min, 0 = off) | unsignedInt 0…120 | 0 |
| Objektype | unsignedInt 0…255 | 255 |
| Aktion bei aus | list | no action |
| Aktion | list | no action |
| Action | list | no action |
| Rain alarm | list | not active |
| Frost alarm | list | not active |
| Extended block function | list | not active |
| Überwachungszeit (min, 0 = aus) | unsignedInt 0…120 | 0 |
| Action at blocking (value=1) | list | no action |
| Verhalten bei Busspannungsausfall | list | no action |
| Behavior at bus power up | list | no action |
| Reaction when bus power up | list | no action |
| Save scenes | list | not active |
| Scene A - position | list | 0% |
| Scene Number A | list | not active |
| Scene A - position of slats | list | 0% |
| Scene B - position | list | 0% |
| Scene Number B | list | not active |
| Scene C - position | list | 0% |
| Scene B - position of slats | list | 0% |
| Scene Number C | list | not active |
| Scene D - position | list | 0% |
| Scene Number D | list | not active |
| Scene C - position of slats | list | 0% |
| Scene E - position | list | 0% |
| Scene Number E | list | not active |
| Scene F - position | list | 0% |
| Scene D - position of slats | list | 0% |
| Scene Number F | list | not active |
| Scene G - position | list | 0% |
| Scene Number G | list | not active |
| Scene E - position of slats | list | 0% |
| Scene H - position | list | 0% |
| Scene Number H | list | not active |
| Scene F - position of slats | list | 0% |
| Scene G - position of slats | list | 0% |
| Scene H - position of slats | list | 0% |
| Automatikobjekte | unsignedInt 255…255 | 255 |
| Automatic objects | list | Block A |
| Automatic function 1 - Position | list | 0% |
| Automatic function 2 - Position | list | 0% |
| Automatic function 1 - position of slats | list | 0% |
| Automatic function 3 - Position | list | 0% |
| Automatic function 4 - Position | list | 0% |
| Automatic function 2 - position of slats | list | 0% |
| Automatic function 3 - position of slats | list | 0% |
| Automatic function 4 - position of slats | list | 0% |
| Dummy Objekte | list | not active |
| Block Up/Down movement | list | not active |
| Block absolute position mode | list | not active |
| Block automatic mode | list | not active |
| Block scene mode | list | not active |
| Settings for object "Block universal mode" | list | not active |
| Object "Block absolute position" | list | not active |
| Manuell enable 0 | unsignedInt 0…255 | 0 |
| Block of absolut position via object "Shutter Up/Down" | list | not active |
| Time for up- / downward movement (sec) | list | same |
| Time for upward movement (sec) | unsignedInt 0…10000 | 45 |
| Time for downward movement (sec) | unsignedInt 0…10000 | 45 |
| Status objects | list | not active |
| Short term operation | list | not active |
| Time for short term operation (ms) | unsignedInt 50…1000 | 200 |
| Status object for visualization | list | Status current direction |
| Block override if upper position is reached | list | not active |
| Start up automatic position (value = 1) | list | always |
| Action at return of automatic position (value = 0) | list | not active |
| Object for reference drive | list | not active |
| Action at value = 0 | list | no function |
| Action at value = 1 | list | Drive to position |
| Position of slats | list | 100% |
| Position of Shutter | list | 50% |
| Position of Blinds | list | 50% |
| Return will be executed if current position is equal to automatic position | text | <- HINWEIS |
| Option for automatic | list | not active |
| Channel react on | list | Automatic position 1 - 4 |
Version history
| Application | App no | Fingerprint | First seen | Size | File |
|---|---|---|---|---|---|
| Blinds and Shutters 1-fold 1.0 latest | $00EC | 3C3F | 2026-11-25 | 137 KB | Download |
About this file
This is the official ETS product database for the MDT technologies GmbH KNX RF+ Shutter Actuator 1-fold, UP (RF-JAL1UP.01), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.
More from MDT technologies GmbH
- RF-AKD230CC.02S KNX RF+ LED Controller CC/CV 30 W / 230 V 2-channel RF-AKD230CC.02S
- RF-AKD260CC.02S KNX RF+ LED Controller CC/CV 60 W / 230 V 2-channel RF-AKD260CC.02S
- KNX RF+ Socket 1-fold RF-AKK1ST.01
- KNX RF+ Switch Actuator 1-fold, UP RF-AKK1UP.01
- KNX RF+ Switch Actuator 2-fold, UP RF-AKK2UP.01
- KNX RF+ Socket with active power meter RF-AZK1ST.01
- RF-FGxS.01S KNX RF+ Window Handle, Secure RF-FGxS.01S
- RF-FKxx.01S KNX RF Window Contact RF-FKWS.01S
- KNX RF+ Glass Push Button 4-fold Plus RF-GTA4x.01
- KNX RF+ Glass Push Button 8-fold Plus RF-GTA8x.01
- KNX RF+ Glass Push Button 4-fold Plus, Temperature RF-GTT4x.01
- KNX RF+ Glass Push Button 8-fold Plus, Temperature RF-GTT8x.01