KNX Database

KNX RF+ Shutter Actuator 1-fold, UP RF-JAL1UP.01

MDT technologies GmbH · Order number RF-JAL1UP.01 · KNX RF+ Device › KNX RF+ Shutter Actuator

Flush mounted 230VAC, 10A, motors until 300W

Download .knxprod Blinds and Shutters 1-fold 1.0 · 137 KB

Product

ManufacturerMDT technologies GmbH
Product nameKNX RF+ Shutter Actuator 1-fold, UP
Order numberRF-JAL1UP.01
HardwareKNX RF+ Funk Jalousieaktor 1-fach, UP
MediumKNX RF
Rail mountedNo
Device kindRFRetransmitter
RegistrationCertified · 2015-09-17
Languagesde-DE, en-US, es-ES, fr-FR
Catalog entryM-0083_H-2.2E46-2_HP-00EC-10-3C3F_CI-RF.2DJAL1UP.2E01-1
Fingerprint3C3F
SHA-25667d5722cbc14fa18a489fc5c590e1164c9634a8c5efa91d8d442a8e56548ab73
First seen2026-11-25
Markets69 markets

Application program: Blinds and Shutters 1-fold 1.0

Application number$00EC
Version1.0
Mask versionMV-2705 (RF 7.5)
KNX Data SecureNo
Minimum ETS version5.0
Parameters138
Group objects38
Group objects (38)
NoNameFunctionSizeDPTFlags
0all ChannelsBlinds up/down1 Bit1.8 up/downCW
1all ChannelsSlats adjustment /Stop1 Bit1.9 open/closeCW
2all ChannelsStop1 Bit1.1 switchCW
3all ChannelsAbsolute position1 Byte5.1 percentage (0..100%)CW
4all ChannelsAbsolute position of slats1 Byte5.1 percentage (0..100%)CW
5Automatic AAutomatic position 11 Bit1.1 switchCW
6Automatic AAutomatic position 21 Bit1.1 switchCW
7Automatic AAutomatic position 31 Bit1.1 switchCW
8Automatic AAutomatic position 41 Bit1.1 switchCW
9Automatic BAutomatic position 11 Bit1.1 switchCW
10Automatic BAutomatic position 21 Bit1.1 switchCW
11Automatic BAutomatic position 31 Bit1.1 switchCW
12Automatic BAutomatic position 41 Bit1.1 switchCW
13Channel AShutter up/down1 Bit1.8 up/downCW
13Channel ABlinds up/down1 Bit1.8 up/downCW
14Channel ASlats adjustment /Stop1 Bit1.9 open/closeCW
14Channel AShort term operation1 Bit1.9 open/closeCW
15Channel AStop1 Bit1.1 switchCW
16Channel AScene1 Byte17.1 scene numberCW
17Channel AStatus current direction1 Bit1.8 up/downCRT
17Channel AStatus of movement1 Bit1.8 up/downCRT
17Channel AStatus of movement1 Bit1.10 start/stopCRT
18Channel AAbsolute position1 Byte5.1 percentage (0..100%)CW
19Channel AAbsolute position of slats1 Byte5.1 percentage (0..100%)CW
20Channel AStatus current position1 Byte5.1 percentage (0..100%)CRT
21Channel AStatus cur. position of slats1 Byte5.1 percentage (0..100%)CRT
22Channel ACurrent position valid1 Bit1.2 booleanCRT
23Channel AStart driving to reference1 Bit1.1 switchCW
24Channel ADrive to limitation1 Bit1.8 up/downCW
24Channel ADrive to position1 Bit1.1 switchCW
25Channel AStatus upper Position1 Bit1.11 stateCRT
26Channel AStatus lower Position1 Bit1.11 stateCRT
27Channel ABlock absolute position mode1 Bit1.3 enableCW
28Channel ABlock universal mode1 Bit1.3 enableCW
29Channel AWind alarm1 Bit1.5 alarmCW
30Channel ARain alarm1 Bit1.5 alarmCW
31Channel AFrost alarm1 Bit1.5 alarmCW
32Channel ABlock1 Bit1.3 enableCW
Parameters (113)
ParameterTypeDefault
Channel AlistBlinds
Minimale Verfahrzeit (ms)unsignedInt 1…1000050
ebmlistShutter
Time for height adjustment (sec)unsignedInt 0…1000045
Step time for slat adjustment (ms)unsignedInt 50…1000200
Lamellenverstellzeit (ms)unsignedInt 1…11
Slat adjustment time (ms)unsignedInt 10…100001200
Pause at change of direction (ms)unsignedInt 100…10001000
Switch-on delay motor (ms)unsignedInt 0…255200
Switch-off delay motor (ms)unsignedInt 0…255200
Extension of movement timelist5%
Position of slats at end of drivinglist100%
Absolut enable 0unsignedInt 0…2554
Automaitk enable 1unsignedInt 0…2550
Objects for absolute positionlistnot active
Reaction after driving to referencelistno reaction
Function object number 24listnot active
Lower limitlist0%
Upper limitlist100%
Aktion Sperrenlistno action
Scenelistnot active
Automatic functionlistnot active
Alarm and block functionslistnot active
AlarmobjekteunsignedInt 255…255255
AlarmobjekteunsignedInt 0…70
KogikcoperationunsignedInt 2…22
invertMaskunsignedInt 0…655350
inputMaskunsignedInt 0…6553515
Order of alarmslistWind, Rain, Frost, Block
bitMask of inputunsignedInt 0…655358
bitMask of inputunsignedInt 0…655354
bitMask of inputunsignedInt 0…655352
bitMask of inputunsignedInt 0…655351
off Action MaskunsignedInt 0…6553514
Action at reset of alarms / blocklistno action
Action at reset of alarmslistno action
Wind alarmlistnot active
Cycle Time (min, 0 = off)unsignedInt 0…1200
ObjektypeunsignedInt 0…255255
Aktion bei auslistno action
Aktionlistno action
Actionlistno action
Rain alarmlistnot active
Frost alarmlistnot active
Extended block functionlistnot active
Überwachungszeit (min, 0 = aus)unsignedInt 0…1200
Action at blocking (value=1)listno action
Verhalten bei Busspannungsausfalllistno action
Behavior at bus power uplistno action
Reaction when bus power uplistno action
Save sceneslistnot active
Scene A - positionlist0%
Scene Number Alistnot active
Scene A - position of slatslist0%
Scene B - positionlist0%
Scene Number Blistnot active
Scene C - positionlist0%
Scene B - position of slatslist0%
Scene Number Clistnot active
Scene D - positionlist0%
Scene Number Dlistnot active
Scene C - position of slatslist0%
Scene E - positionlist0%
Scene Number Elistnot active
Scene F - positionlist0%
Scene D - position of slatslist0%
Scene Number Flistnot active
Scene G - positionlist0%
Scene Number Glistnot active
Scene E - position of slatslist0%
Scene H - positionlist0%
Scene Number Hlistnot active
Scene F - position of slatslist0%
Scene G - position of slatslist0%
Scene H - position of slatslist0%
AutomatikobjekteunsignedInt 255…255255
Automatic objectslistBlock A
Automatic function 1 - Positionlist0%
Automatic function 2 - Positionlist0%
Automatic function 1 - position of slatslist0%
Automatic function 3 - Positionlist0%
Automatic function 4 - Positionlist0%
Automatic function 2 - position of slatslist0%
Automatic function 3 - position of slatslist0%
Automatic function 4 - position of slatslist0%
Dummy Objektelistnot active
Block Up/Down movementlistnot active
Block absolute position modelistnot active
Block automatic modelistnot active
Block scene modelistnot active
Settings for object "Block universal mode"listnot active
Object "Block absolute position"listnot active
Manuell enable 0unsignedInt 0…2550
Block of absolut position via object "Shutter Up/Down"listnot active
Time for up- / downward movement (sec)listsame
Time for upward movement (sec)unsignedInt 0…1000045
Time for downward movement (sec)unsignedInt 0…1000045
Status objectslistnot active
Short term operationlistnot active
Time for short term operation (ms)unsignedInt 50…1000200
Status object for visualizationlistStatus current direction
Block override if upper position is reachedlistnot active
Start up automatic position (value = 1)listalways
Action at return of automatic position (value = 0)listnot active
Object for reference drivelistnot active
Action at value = 0listno function
Action at value = 1listDrive to position
Position of slatslist100%
Position of Shutterlist50%
Position of Blindslist50%
Return will be executed if current position is equal to automatic positiontext<- HINWEIS
Option for automaticlistnot active
Channel react onlistAutomatic position 1 - 4

Version history

ApplicationApp noFingerprintFirst seenSizeFile
Blinds and Shutters 1-fold 1.0 latest$00EC3C3F2026-11-25137 KBDownload

About this file

This is the official ETS product database for the MDT technologies GmbH KNX RF+ Shutter Actuator 1-fold, UP (RF-JAL1UP.01), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.

More from MDT technologies GmbH

All MDT technologies GmbH products