KNX RF+ Socket with active power meter RF-AZK1ST.01
MDT technologies GmbH · Order number RF-AZK1ST.01 · KNX RF+ Device › KNX RF+ Sockets
Socket in plug adapter with active power meter 230VAC, 16A ohmical load
Download .knxprod Switching, Staircase, Active power meter 1f 1.0 · 128 KB
Product
| Manufacturer | MDT technologies GmbH |
|---|---|
| Product name | KNX RF+ Socket with active power meter |
| Order number | RF-AZK1ST.01 |
| Hardware | KNX RF+ Funk Steckdose mit Witkleistungszähler |
| Medium | KNX RF |
| Rail mounted | No |
| Device kind | RFRetransmitter |
| Registration | Registered · 2015-09-17 |
| Languages | de-DE, en-US, es-ES, fr-FR |
| Catalog entry | M-0083_H-2.2E43-2_HP-00E9-10-E9CE_CI-RF.2DAZK1ST.2E01-1 |
| Fingerprint | E9CE |
| SHA-256 | 7953eb885c6f10bd7a2fa37b856753d88fcec00f73e92aa7f32edfb27ad2a8e4 |
| First seen | 2026-11-25 |
| Markets | 69 markets |
Application program: Switching, Staircase, Active power meter 1f 1.0
| Application number | $00E9 |
|---|---|
| Version | 1.0 |
| Mask version | MV-2705 (RF 7.5) |
| KNX Data Secure | No |
| Minimum ETS version | 5.0 |
| Parameters | 98 |
| Group objects | 26 |
Group objects (26)
| No | Name | Function | Size | DPT | Flags |
|---|---|---|---|---|---|
| 0 | Switch Channel | Switch On/Off | 1 Bit | 1.1 switch | CW |
| 1 | Switch Channel | Staircase | 1 Bit | 1.1 switch | CW |
| 2 | Switch Channel | Block | 1 Bit | 1.3 enable | CW |
| 3 | Switch Channel | Forced | 2 Bit | 2.1 switch control | CW |
| 4 | Switch Channel | Scene | 1 Byte | 17.1 scene number | CW |
| 5 | Switch Channel | State | 1 Bit | 1.11 state | CRT |
| 6 | Switch Channel | Logic 1 | 1 Bit | 1.2 boolean | CW |
| 7 | Switch Channel | Logic 2 | 1 Bit | 1.2 boolean | CW |
| 8 | Active power meter | Active power | 4 Bytes | 14.56 power (W) | CRT |
| 8 | Active power meter | Active power | 2 Bytes | 9.24 power (kW) | CRT |
| 9 | Active power meter | Current value | 2 Bytes | 7.12 current (mA) | CRT |
| 9 | Active power meter | Current value | 2 Bytes | 9.21 current (mA) | CRT |
| 9 | Active power meter | Current value | 4 Bytes | 14.19 electric current (A) | CRT |
| 10 | Active power meter | Voltage value | 4 Bytes | 14.27 electric potential (V) | CRT |
| 11 | Intermediate meter | Active energy (Wh) | 4 Bytes | 13.10 active energy (Wh) | CRT |
| 11 | Intermediate meter | Active energy (kWh) | 4 Bytes | 13.13 active energy (kWh) | CRT |
| 12 | Main meter | Active energy (kWh) | 4 Bytes | 13.13 active energy (kWh) | CRT |
| 13 | Active power meter | Exceedance of load | 1 Bit | 1.1 switch | CRT |
| 14 | Active power meter | Lower deviation of load | 1 Bit | 1.1 switch | CRT |
| 15 | Active power meter | Exceedance of current | 1 Bit | 1.1 switch | CRT |
| 16 | Active power meter | Lower deviation of current | 1 Bit | 1.1 switch | CRT |
| 17 | Active power meter | Exceedance of voltage | 1 Bit | 1.1 switch | CRT |
| 18 | Active power meter | Lower deviation of voltage | 1 Bit | 1.1 switch | CRT |
| 19 | Intermediate meter | Reset | 1 Bit | 1.3 enable | CW |
| 20 | Main meter | Reset | 1 Bit | 1.3 enable | CW |
| 21 | Central function | Switch | 1 Bit | 1.1 switch | CW |
Parameters (71)
| Parameter | Type | Default |
|---|---|---|
| ### | unsignedInt 0…255 | 1 |
| Switch Channel | list | Switch |
| Time for staircase [s] | unsignedInt 0…30000 | 0 |
| Mode | list | normaly opend |
| Prewarning time in [s] | unsignedInt 0…30000 | 0 |
| Prewarning | list | not activ |
| Manual switching off | list | not activ |
| Warning time [s] | unsignedInt 0…30000 | 1 |
| Verlängern bei Treppenlicht | list | Disable |
| On delay [s] | unsignedInt 0…30000 | 0 |
| Extend staircase time | list | not activ |
| Off delay [s] | unsignedInt 0…30000 | 0 |
| Zyklisches senden dess aktuellen Istwertes | unsignedInt 0…30000 | 0 |
| Save scene | list | disabled |
| State for recalling after receiving Szene number | list | Off |
| Behaviour when locked | list | no change |
| Behaviour when unlocked | list | no change |
| invertieren des Lock Objektes | list | not inverted |
| Behaviour at bus power up | list | no change |
| Bus Power Up Message Delay | list | 1 s |
| Logical functions | list | not activ |
| active Logic Inputs | list | not activ |
| Logic operations | list | OR |
| Scene | list | not activ |
| logic Operations | list | OR |
| Scene A | list | Off |
| Scene number A | list | not used |
| Scene B | list | Off |
| Scene number B | list | not used |
| Scene C | list | Off |
| Scene number C | list | not used |
| Scene D | list | Off |
| Scene number D | list | not used |
| Scene E | list | Off |
| Scene number E | list | not used |
| Scene F | list | Off |
| Scene number F | list | not used |
| Scene G | list | Off |
| Scene number G | list | not used |
| Scene H | list | Off |
| Scene number H | list | not used |
| Send cyclic | list | no send |
| Send cyclic meter reading of intermediate meter | list | no send |
| Send cyclic meter reading of main meter | list | no send |
| Value for exceedance of load in W [0…3680] | unsignedInt 0…3680 | 100 |
| Value for lower deviation of load in W [0…3680] | unsignedInt 1…3680 | 5 |
| Value for exceedance of current in mA [3…16000] | unsignedInt 3…16000 | 100 |
| Value for lower deviation of current in mA [3…16000] | unsignedInt 3…16000 | 300 |
| Value for exceedance of voltage in V [180…300] | unsignedInt 180…300 | 240 |
| Value for lower deviation of voltage in V [180…300] | unsignedInt 180…300 | 210 |
| Enable active power measurement | list | yes |
| Object selection | list | 4Byte floating value in W (DPT 14.056) |
| Send value at changes | list | no send |
| Hysteresis in % | unsignedInt 10…100 | 10 |
| Behavior at exceeding | list | send nothing |
| Behavior at not exceeding | list | send nothing |
| Behavior at not deviating | list | send nothing |
| Behavior at deviating | list | send nothing |
| Object selection | list | Value in mA (DPT 7.012) |
| Enable current measurement | list | yes |
| Monitoring exceedance of load | list | not activ |
| Monitoring lower deviation of load | list | not activ |
| Monitoring exceedance of current | list | not activ |
| Monitoring lower deviation of current | list | not activ |
| Enable voltage measurement | list | yes |
| Monitoring exceedance of voltage | list | not activ |
| Monitoring lower deviation of voltage | list | not activ |
| Main and Intermediate meter | list | no |
| Object selection for intermediate meter | list | Value in Wh (DPT 13.010) |
| Behavior after bus power retern | list | no reset |
| Retention time by exceedance in sec. | unsignedInt 0…30000 | 0 |
Version history
| Application | App no | Fingerprint | First seen | Size | File |
|---|---|---|---|---|---|
| Switching, Staircase, Active power meter 1f 1.0 latest | $00E9 | E9CE | 2026-11-25 | 128 KB | Download |
About this file
This is the official ETS product database for the MDT technologies GmbH KNX RF+ Socket with active power meter (RF-AZK1ST.01), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.
More from MDT technologies GmbH
- RF-AKD230CC.02S KNX RF+ LED Controller CC/CV 30 W / 230 V 2-channel RF-AKD230CC.02S
- RF-AKD260CC.02S KNX RF+ LED Controller CC/CV 60 W / 230 V 2-channel RF-AKD260CC.02S
- KNX RF+ Socket 1-fold RF-AKK1ST.01
- KNX RF+ Switch Actuator 1-fold, UP RF-AKK1UP.01
- KNX RF+ Switch Actuator 2-fold, UP RF-AKK2UP.01
- RF-FGxS.01S KNX RF+ Window Handle, Secure RF-FGxS.01S
- RF-FKxx.01S KNX RF Window Contact RF-FKWS.01S
- KNX RF+ Glass Push Button 4-fold Plus RF-GTA4x.01
- KNX RF+ Glass Push Button 8-fold Plus RF-GTA8x.01
- KNX RF+ Glass Push Button 4-fold Plus, Temperature RF-GTT4x.01
- KNX RF+ Glass Push Button 8-fold Plus, Temperature RF-GTT8x.01
- KNX RF+ Heating Valve Drive with display and 2 x AA-Batteries, Secure RF-HVA1DAA.01S