JAL-0810.01 Shutter Actuator 8-fold,8TE,230VAC,10A JAL-0810.01
MDT technologies GmbH · Order number JAL-0810.01 · Archive › Actuators › Shutter Actuator
10A, Motors until 600W
Download .knxprod Shutters and Blinds 8-fold 2.8 · 175 KB
Product
| Manufacturer | MDT technologies GmbH |
|---|---|
| Product name | JAL-0810.01 Shutter Actuator 8-fold,8TE,230VAC,10A |
| Order number | JAL-0810.01 |
| Hardware | Jalousieaktor 8-fach, 8TE, 10A |
| Medium | Twisted Pair |
| Bus current (mA) | 5 |
| Rail mounted | Yes |
| Width (mm) | 142.3 |
| Registration | Certified · 2012-02-29 |
| Languages | de-DE, en-US |
| Catalog entry | M-0083_H-40-48_HP-0028-28-C21C_CI-JAL.2D0810.2E01-3 |
| Fingerprint | C21C |
| SHA-256 | ecd3b1621f58999e480a1306a93834966cd42ad4ccf896fe7fa0bae374e254da |
| First seen | 2026-11-25 |
| Markets | 69 markets |
Application program: Shutters and Blinds 8-fold 2.8
| Application number | $0028 |
|---|---|
| Version | 2.8 |
| Mask version | MV-0701 (7.1) |
| KNX Data Secure | No |
| Minimum ETS version | 4.0 |
| Parameters | 1129 |
| Group objects | 205 |
Group objects (205)
| No | Name | Function | Size | DPT | Flags |
|---|---|---|---|---|---|
| 0 | all Channels | Shutter up/down | 1 Bit | 1.8 up/down | CW |
| 1 | all Channels | Slats adjustment /Stop | 1 Bit | 1.9 open/close | CW |
| 2 | all Channels | Stop | 1 Bit | 1.1 switch | CW |
| 3 | all Channels | Absolute position | 1 Byte | 5.1 percentage (0..100%) | CW |
| 4 | all Channels | Absolute position of slats | 1 Byte | 5.1 percentage (0..100%) | CW |
| 5 | Automatic A | Automatic position 1 | 1 Bit | 1.1 switch | CW |
| 6 | Automatic A | Automatic position 2 | 1 Bit | 1.1 switch | CW |
| 7 | Automatic A | Automatic position 3 | 1 Bit | 1.1 switch | CW |
| 8 | Automatic A | Automatic position 4 | 1 Bit | 1.1 switch | CW |
| 9 | Automatic B | Automatic position 1 | 1 Bit | 1.1 switch | CW |
| 10 | Automatic B | Automatic position 2 | 1 Bit | 1.1 switch | CW |
| 11 | Automatic B | Automatic position 3 | 1 Bit | 1.1 switch | CW |
| 12 | Automatic B | Automatic position 4 | 1 Bit | 1.1 switch | CW |
| 13 | Channel A | Shutter up/down | 1 Bit | 1.8 up/down | CW |
| 13 | Channel A | Blinds up/down | 1 Bit | 1.8 up/down | CW |
| 14 | Channel A | Slats adjustment /Stop | 1 Bit | 1.9 open/close | CW |
| 14 | Channel A | Short term operation | 1 Bit | 1.9 open/close | CW |
| 15 | Channel A | Stop | 1 Bit | 1.1 switch | CW |
| 16 | Channel A | Scene | 1 Byte | CW | |
| 17 | Channel A | Status current direction | 1 Bit | 1.8 up/down | CRT |
| 17 | Channel A | Status of movement | 1 Bit | 1.10 start/stop | CRT |
| 18 | Channel A | Absolute position | 1 Byte | 5.1 percentage (0..100%) | CW |
| 19 | Channel A | Absolute position of slats | 1 Byte | 5.1 percentage (0..100%) | CW |
| 20 | Channel A | Status current position | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 21 | Channel A | Status cur. position of slats | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 22 | Channel A | Current position valid | 1 Bit | 1.2 boolean | CRT |
| 23 | Channel A | Start driving to reference | 1 Bit | 1.1 switch | CW |
| 24 | Channel A | Drive to limitation | 1 Bit | 1.8 up/down | CW |
| 24 | Channel A | Drive to position | 1 Bit | 1.1 switch | CW |
| 25 | Channel A | Status upper Position | 1 Bit | CRT | |
| 26 | Channel A | Status lower Position | 1 Bit | CRT | |
| 27 | Channel A | Block absolute position mode | 1 Bit | 1.3 enable | CW |
| 28 | Channel A | Block universal mode | 1 Bit | 1.3 enable | CW |
| 29 | Channel A | Wind alarm | 1 Bit | CW | |
| 30 | Channel A | Rain alarm | 1 Bit | CW | |
| 31 | Channel A | Frost alarm | 1 Bit | CW | |
| 32 | Channel A | Block | 1 Bit | 1.3 enable | CW |
| 33 | Channel B | Shutter up/down | 1 Bit | 1.8 up/down | CW |
| 33 | Channel B | Blinds up/down | 1 Bit | 1.8 up/down | CW |
| 34 | Channel B | Slats adjustment /Stop | 1 Bit | 1.9 open/close | CW |
| 34 | Channel B | Short term operation | 1 Bit | 1.9 open/close | CW |
| 35 | Channel B | Stop | 1 Bit | 1.1 switch | CW |
| 36 | Channel B | Scene | 1 Byte | CW | |
| 37 | Channel B | Status current direction | 1 Bit | 1.8 up/down | CRT |
| 37 | Channel B | Status of movement | 1 Bit | 1.10 start/stop | CRT |
| 38 | Channel B | Absolute position | 1 Byte | 5.1 percentage (0..100%) | CW |
| 39 | Channel B | Absolute position of slats | 1 Byte | 5.1 percentage (0..100%) | CW |
| 40 | Channel B | Status current position | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 41 | Channel B | Status cur. position of slats | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 42 | Channel B | Current position valid | 1 Bit | 1.2 boolean | CRT |
| 43 | Channel B | Start driving to reference | 1 Bit | 1.1 switch | CW |
| 44 | Channel B | Drive to limitation | 1 Bit | 1.8 up/down | CW |
| 44 | Channel B | Drive to position | 1 Bit | 1.1 switch | CW |
| 45 | Channel B | Status upper Position | 1 Bit | CRT | |
| 46 | Channel B | Status lower Position | 1 Bit | CRT | |
| 47 | Channel B | Block absolute position mode | 1 Bit | 1.3 enable | CW |
| 48 | Channel B | Block universal mode | 1 Bit | 1.3 enable | CW |
| 49 | Channel B | Wind alarm | 1 Bit | CW | |
| 50 | Channel B | Rain alarm | 1 Bit | CW | |
| 51 | Channel B | Frost alarm | 1 Bit | CW | |
| 52 | Channel B | Block | 1 Bit | 1.3 enable | CW |
| 53 | Channel C | Shutter up/down | 1 Bit | 1.8 up/down | CW |
| 53 | Channel C | Blinds up/down | 1 Bit | 1.8 up/down | CW |
| 54 | Channel C | Slats adjustment /Stop | 1 Bit | 1.9 open/close | CW |
| 54 | Channel C | Short term operation | 1 Bit | 1.9 open/close | CW |
| 55 | Channel C | Stop | 1 Bit | 1.1 switch | CW |
| 56 | Channel C | Scene | 1 Byte | CW | |
| 57 | Channel C | Status current direction | 1 Bit | 1.8 up/down | CRT |
| 57 | Channel C | Status of movement | 1 Bit | 1.10 start/stop | CRT |
| 58 | Channel C | Absolute position | 1 Byte | 5.1 percentage (0..100%) | CW |
| 59 | Channel C | Absolute position of slats | 1 Byte | 5.1 percentage (0..100%) | CW |
| 60 | Channel C | Status current position | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 61 | Channel C | Status cur. position of slats | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 62 | Channel C | Current position valid | 1 Bit | 1.2 boolean | CRT |
| 63 | Channel C | Start driving to reference | 1 Bit | 1.1 switch | CW |
| 64 | Channel C | Drive to limitation | 1 Bit | 1.8 up/down | CW |
| 64 | Channel C | Drive to position | 1 Bit | 1.1 switch | CW |
| 65 | Channel C | Status upper Position | 1 Bit | CRT | |
| 66 | Channel C | Status lower Position | 1 Bit | CRT | |
| 67 | Channel C | Block absolute position mode | 1 Bit | 1.3 enable | CW |
| 68 | Channel C | Block universal mode | 1 Bit | 1.3 enable | CW |
| 69 | Channel C | Wind alarm | 1 Bit | CW | |
| 70 | Channel C | Rain alarm | 1 Bit | CW | |
| 71 | Channel C | Frost alarm | 1 Bit | CW | |
| 72 | Channel C | Block | 1 Bit | 1.3 enable | CW |
| 73 | Channel D | Shutter up/down | 1 Bit | 1.8 up/down | CW |
| 73 | Channel D | Blinds up/down | 1 Bit | 1.8 up/down | CW |
| 74 | Channel D | Slats adjustment /Stop | 1 Bit | 1.9 open/close | CW |
| 74 | Channel D | Short term operation | 1 Bit | 1.9 open/close | CW |
| 75 | Channel D | Stop | 1 Bit | 1.1 switch | CW |
| 76 | Channel D | Scene | 1 Byte | CW | |
| 77 | Channel D | Status current direction | 1 Bit | 1.8 up/down | CRT |
| 77 | Channel D | Status of movement | 1 Bit | 1.10 start/stop | CRT |
| 78 | Channel D | Absolute position | 1 Byte | 5.1 percentage (0..100%) | CW |
| 79 | Channel D | Absolute position of slats | 1 Byte | 5.1 percentage (0..100%) | CW |
| 80 | Channel D | Status current position | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 81 | Channel D | Status cur. position of slats | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 82 | Channel D | Current position valid | 1 Bit | 1.2 boolean | CRT |
| 83 | Channel D | Start driving to reference | 1 Bit | 1.1 switch | CW |
| 84 | Channel D | Drive to limitation | 1 Bit | 1.8 up/down | CW |
| 84 | Channel D | Drive to position | 1 Bit | 1.1 switch | CW |
| 85 | Channel D | Status upper Position | 1 Bit | CRT | |
| 86 | Channel D | Status lower Position | 1 Bit | CRT | |
| 87 | Channel D | Block absolute position mode | 1 Bit | 1.3 enable | CW |
| 88 | Channel D | Block universal mode | 1 Bit | 1.3 enable | CW |
| 89 | Channel D | Wind alarm | 1 Bit | CW | |
| 90 | Channel D | Rain alarm | 1 Bit | CW | |
| 91 | Channel D | Frost alarm | 1 Bit | CW | |
| 92 | Channel D | Block | 1 Bit | 1.3 enable | CW |
| 93 | Channel E | Shutter up/down | 1 Bit | 1.8 up/down | CW |
| 93 | Channel E | Blinds up/down | 1 Bit | 1.8 up/down | CW |
| 94 | Channel E | Slats adjustment /Stop | 1 Bit | 1.9 open/close | CW |
| 94 | Channel E | Short term operation | 1 Bit | 1.9 open/close | CW |
| 95 | Channel E | Stop | 1 Bit | 1.1 switch | CW |
| 96 | Channel E | Scene | 1 Byte | CW | |
| 97 | Channel E | Status current direction | 1 Bit | 1.8 up/down | CRT |
| 97 | Channel E | Status of movement | 1 Bit | 1.10 start/stop | CRT |
| 98 | Channel E | Absolute position | 1 Byte | 5.1 percentage (0..100%) | CW |
| 99 | Channel E | Absolute position of slats | 1 Byte | 5.1 percentage (0..100%) | CW |
| 100 | Channel E | Status current position | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 101 | Channel E | Status cur. position of slats | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 102 | Channel E | Current position valid | 1 Bit | 1.2 boolean | CRT |
| 103 | Channel E | Start driving to reference | 1 Bit | 1.1 switch | CW |
| 104 | Channel E | Drive to limitation | 1 Bit | 1.8 up/down | CW |
| 104 | Channel E | Drive to position | 1 Bit | 1.1 switch | CW |
| 105 | Channel E | Status upper Position | 1 Bit | CRT | |
| 106 | Channel E | Status lower Position | 1 Bit | CRT | |
| 107 | Channel E | Block absolute position mode | 1 Bit | 1.3 enable | CW |
| 108 | Channel E | Block universal mode | 1 Bit | 1.3 enable | CW |
| 109 | Channel E | Wind alarm | 1 Bit | CW | |
| 110 | Channel E | Rain alarm | 1 Bit | CW | |
| 111 | Channel E | Frost alarm | 1 Bit | CW | |
| 112 | Channel E | Block | 1 Bit | 1.3 enable | CW |
| 113 | Channel F | Shutter up/down | 1 Bit | 1.8 up/down | CW |
| 113 | Channel F | Blinds up/down | 1 Bit | 1.8 up/down | CW |
| 114 | Channel F | Slats adjustment /Stop | 1 Bit | 1.9 open/close | CW |
| 114 | Channel F | Short term operation | 1 Bit | 1.9 open/close | CW |
| 115 | Channel F | Stop | 1 Bit | 1.1 switch | CW |
| 116 | Channel F | Scene | 1 Byte | CW | |
| 117 | Channel F | Status current direction | 1 Bit | 1.8 up/down | CRT |
| 117 | Channel F | Status of movement | 1 Bit | 1.10 start/stop | CRT |
| 118 | Channel F | Absolute position | 1 Byte | 5.1 percentage (0..100%) | CW |
| 119 | Channel F | Absolute position of slats | 1 Byte | 5.1 percentage (0..100%) | CW |
| 120 | Channel F | Status current position | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 121 | Channel F | Status cur. position of slats | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 122 | Channel F | Current position valid | 1 Bit | 1.2 boolean | CRT |
| 123 | Channel F | Start driving to reference | 1 Bit | 1.1 switch | CW |
| 124 | Channel F | Drive to limitation | 1 Bit | 1.8 up/down | CW |
| 124 | Channel F | Drive to position | 1 Bit | 1.1 switch | CW |
| 125 | Channel F | Status upper Position | 1 Bit | CRT | |
| 126 | Channel F | Status lower Position | 1 Bit | CRT | |
| 127 | Channel F | Block absolute position mode | 1 Bit | 1.3 enable | CW |
| 128 | Channel F | Block universal mode | 1 Bit | 1.3 enable | CW |
| 129 | Channel F | Wind alarm | 1 Bit | CW | |
| 130 | Channel F | Rain alarm | 1 Bit | CW | |
| 131 | Channel F | Frost alarm | 1 Bit | CW | |
| 132 | Channel F | Block | 1 Bit | 1.3 enable | CW |
| 133 | Channel G | Shutter up/down | 1 Bit | 1.8 up/down | CW |
| 133 | Channel G | Blinds up/down | 1 Bit | 1.8 up/down | CW |
| 134 | Channel G | Slats adjustment /Stop | 1 Bit | 1.9 open/close | CW |
| 134 | Channel G | Short term operation | 1 Bit | 1.9 open/close | CW |
| 135 | Channel G | Stop | 1 Bit | 1.1 switch | CW |
| 136 | Channel G | Scene | 1 Byte | CW | |
| 137 | Channel G | Status current direction | 1 Bit | 1.8 up/down | CRT |
| 137 | Channel G | Status of movement | 1 Bit | 1.10 start/stop | CRT |
| 138 | Channel G | Absolute position | 1 Byte | 5.1 percentage (0..100%) | CW |
| 139 | Channel G | Absolute position of slats | 1 Byte | 5.1 percentage (0..100%) | CW |
| 140 | Channel G | Status current position | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 141 | Channel G | Status cur. position of slats | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 142 | Channel G | Current position valid | 1 Bit | 1.2 boolean | CRT |
| 143 | Channel G | Start driving to reference | 1 Bit | 1.1 switch | CW |
| 144 | Channel G | Drive to limitation | 1 Bit | 1.8 up/down | CW |
| 144 | Channel G | Drive to position | 1 Bit | 1.1 switch | CW |
| 145 | Channel G | Status upper Position | 1 Bit | CRT | |
| 146 | Channel G | Status lower Position | 1 Bit | CRT | |
| 147 | Channel G | Block absolute position mode | 1 Bit | 1.3 enable | CW |
| 148 | Channel G | Block universal mode | 1 Bit | 1.3 enable | CW |
| 149 | Channel G | Wind alarm | 1 Bit | CW | |
| 150 | Channel G | Rain alarm | 1 Bit | CW | |
| 151 | Channel G | Frost alarm | 1 Bit | CW | |
| 152 | Channel G | Block | 1 Bit | 1.3 enable | CW |
| 153 | Channel H | Shutter up/down | 1 Bit | 1.8 up/down | CW |
| 153 | Channel H | Blinds up/down | 1 Bit | 1.8 up/down | CW |
| 154 | Channel H | Slats adjustment /Stop | 1 Bit | 1.9 open/close | CW |
| 154 | Channel H | Short term operation | 1 Bit | 1.9 open/close | CW |
| 155 | Channel H | Stop | 1 Bit | 1.1 switch | CW |
| 156 | Channel H | Scene | 1 Byte | CW | |
| 157 | Channel H | Status current direction | 1 Bit | 1.8 up/down | CRT |
| 157 | Channel H | Status of movement | 1 Bit | 1.10 start/stop | CRT |
| 158 | Channel H | Absolute position | 1 Byte | 5.1 percentage (0..100%) | CW |
| 159 | Channel H | Absolute position of slats | 1 Byte | 5.1 percentage (0..100%) | CW |
| 160 | Channel H | Status current position | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 161 | Channel H | Status cur. position of slats | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 162 | Channel H | Current position valid | 1 Bit | 1.2 boolean | CRT |
| 163 | Channel H | Start driving to reference | 1 Bit | 1.1 switch | CW |
| 164 | Channel H | Drive to limitation | 1 Bit | 1.8 up/down | CW |
| 164 | Channel H | Drive to position | 1 Bit | 1.1 switch | CW |
| 165 | Channel H | Status upper Position | 1 Bit | CRT | |
| 166 | Channel H | Status lower Position | 1 Bit | CRT | |
| 167 | Channel H | Block absolute position mode | 1 Bit | 1.3 enable | CW |
| 168 | Channel H | Block universal mode | 1 Bit | 1.3 enable | CW |
| 169 | Channel H | Wind alarm | 1 Bit | CW | |
| 170 | Channel H | Rain alarm | 1 Bit | CW | |
| 171 | Channel H | Frost alarm | 1 Bit | CW | |
| 172 | Channel H | Block | 1 Bit | 1.3 enable | CW |
Parameters (137)
| Parameter | Type | Default |
|---|---|---|
| Channel A | list | not active |
| Channel B | list | not active |
| Channel C | list | not active |
| Channel D | list | not active |
| Channel E | list | not active |
| Channel F | list | not active |
| Channel G | list | not active |
| Minimale Verfahrzeit (ms) | unsignedInt 1…10000 | 50 |
| ebm | list | not active |
| Time for movement (sec) | unsignedInt 0…10000 | 45 |
| Schrittweite für Lamellenverstellung (ms) | unsignedInt 1…1 | 1 |
| Step time for slat adjustment (ms) | unsignedInt 50…1000 | 200 |
| Lamellenverstellzeit (ms) | unsignedInt 1…1 | 1 |
| Slat adjustment time (ms) | unsignedInt 10…10000 | 1200 |
| Pause at change of direction (ms) | unsignedInt 100…1000 | 1000 |
| Switch-on delay motor (ms) | unsignedInt 0…255 | 200 |
| Switch-off delay motor (ms) | unsignedInt 0…255 | 200 |
| Extension of movement time | list | 5% |
| Alarmobjekte | unsignedInt 255…255 | 255 |
| Position of slats at end of driving | list | 100% |
| Absolute Position enable 0 | unsignedInt 0…255 | 4 |
| Automaitk enable 1 | unsignedInt 0…255 | 0 |
| Block manual control | list | not active |
| Manuell enable 0 | unsignedInt 0…255 | 0 |
| Objects for absolute position | list | not active |
| Reaction after driving to reference | list | no reaction |
| Function for Object 24 "Drive to limitation" / "Drive to position" | list | not active |
| Lower limit | list | 0% |
| Upper limit | list | 100% |
| Central objects | list | active |
| Aktion Sperren | list | no action |
| Scene | list | not active |
| Automatic function | list | not active |
| Alarm and block functions | list | not active |
| Alarmobjekte | unsignedInt 0…7 | 0 |
| Logikoperation | unsignedInt 2…2 | 2 |
| invertMask | unsignedInt 0…65535 | 0 |
| inputMask | unsignedInt 0…65535 | 15 |
| Order of alarms | list | Wind, Rain, Frost, Block |
| bitMask of input | unsignedInt 0…65535 | 8 |
| bitMask of input | unsignedInt 0…65535 | 4 |
| bitMask of input | unsignedInt 0…65535 | 2 |
| bitMask of input | unsignedInt 0…65535 | 1 |
| off Action Mask | unsignedInt 0…65535 | 14 |
| Action at reset of alarms / block | list | no action |
| Wind alarm | list | not active |
| Cycle Time (min, 0 = off) | unsignedInt 0…120 | 0 |
| Objektype | unsignedInt 0…255 | 255 |
| Aktion bei aus | list | no action |
| Aktion | list | no action |
| Action | list | no action |
| Rain alarm | list | not active |
| Frost alarm | list | not active |
| Extended block function | list | not active |
| Überwachungszeit (min, 0 = aus) | unsignedInt 0…120 | 0 |
| Action at blocking (value=1) | list | no action |
| Reaction at bus power down | list | no action |
| Reaction when bus power up | list | no action |
| Save scenes | list | not active |
| Scene A - Position | list | 0% |
| Scene Number A | list | 1 |
| Scene A - Position of slats | list | 0% |
| Scene B - Position | list | 0% |
| Scene Number B | list | 2 |
| Scene C - Position | list | 0% |
| Scene B - Position of slats | list | 0% |
| Scene Number C | list | 3 |
| Scene D - Position | list | 0% |
| Scene Number D | list | 4 |
| Scene C - Position of slats | list | 0% |
| Scene E - Position | list | 0% |
| Scene Number E | list | 5 |
| Scene F - Position | list | 0% |
| Scene D - Position of slats | list | 0% |
| Scene Number F | list | 6 |
| Scene G - Position | list | 0% |
| Scene Number G | list | 7 |
| Scene E - Position of slats | list | 0% |
| Scene H - Position | list | 0% |
| Scene Number H | list | 8 |
| Scene F - Position of slats | list | 0% |
| Scene G - Position of slats | list | 0% |
| Scene H - Position of slats | list | 0% |
| Automatikobjekte | unsignedInt 255…255 | 255 |
| Automatic objects | list | Block A |
| Automatic position 1 | list | 0% |
| Automatic position 2 | list | 0% |
| Automatic position 1 - Slats | list | 0% |
| Automatic position 3 | list | 0% |
| Automatic position 4 | list | 0% |
| Automatic position 2 - Slats | list | 0% |
| Automatic position 3 - Slats | list | 0% |
| Automatic position 4 - Slats | list | 0% |
| Block A | list | not active |
| Object "Block absolute position" | list | not active |
| Settings for object "Block universal mode" | list | not active |
| Block Up/Down movement | list | not active |
| Block automatic mode | list | not active |
| Block absolute position mode | list | not active |
| Block scene mode | list | not active |
| Block of absolut position via object "Blinds Up/Down" | list | not active |
| Time for up- / downward movement (sec) | list | same |
| Time for upward movement (sec) | unsignedInt 0…10000 | 45 |
| Time for downward movement (sec) | unsignedInt 0…10000 | 45 |
| Status objects | list | not active |
| Short term operation | list | not active |
| Status object for visualization | list | Status current direction |
| Time for short term operation (ms) | unsignedInt 50…1000 | 200 |
| Block override if upper position is reached | list | not active |
| Start up automatic position (value = 1) | list | always |
| Action at return of automatic position (value = 0) | list | not active |
| Object for reference drive | list | not active |
| Action at value = 1 | list | Drive to position |
| Action at value = 0 | list | no function |
| Position of shutter | list | 50% |
| Position of blinds | list | 50% |
| Position of slats | list | 100% |
| Advanced function only for hardware as from version 3.2 | text | <- HINWEIS |
| Option for automatic only for hardware as from version 3.2 | list | not active |
| Channel react on | list | Automatic position 1 - 4 |
| Return will be executed if current position is equal to automatic position | text | <- HINWEIS |
| Block B | list | not active |
| Function for Object 44 "Drive to limitation" / "Drive to position" | list | not active |
| Alarmobjekte | unsignedInt 0…7 | 1 |
| Function for Object 64 "Drive to limitation" / "Drive to position" | list | not active |
| Alarmobjekte | unsignedInt 0…7 | 2 |
| Channel H | list | not active |
| Function for Object 84 "Drive to limitation" / "Drive to position" | list | not active |
| Alarmobjekte | unsignedInt 0…7 | 3 |
| Function for Object 104 "Drive to limitation" / "Drive to position" | list | not active |
| Alarmobjekte | unsignedInt 0…7 | 4 |
| Function for Object 124 "Drive to limitation" / "Drive to position" | list | not active |
| Alarmobjekte | unsignedInt 0…7 | 5 |
| Function for Object 144 "Drive to limitation" / "Drive to position" | list | not active |
| Alarmobjekte | unsignedInt 0…7 | 6 |
| Function for Object 164 "Drive to limitation" / "Drive to position" | list | not active |
| Alarmobjekte | unsignedInt 0…7 | 7 |
Version history
| Application | App no | Fingerprint | First seen | Size | File |
|---|---|---|---|---|---|
| Shutters and Blinds 8-fold 2.8 latest | $0028 | C21C | 2026-11-25 | 175 KB | Download |
| Blinds and Shutter 8-fold 1.8 | $0028 | E9E8 | 2026-11-25 | 186 KB | Download |
About this file
This is the official ETS product database for the MDT technologies GmbH JAL-0810.01 Shutter Actuator 8-fold,8TE,230VAC,10A (JAL-0810.01), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.
More from MDT technologies GmbH
- AKD-0224V.01 LED Controller 2 channel AKD-0224V.01
- AKD-0324V.01 RGB LED Controller AKD-0324V.01
- AKD-0410V.01 Dimming Control Unit 4-f, 4TE, 1-10V AKD-0410V.01
- AKD-0424R.01 RGBW LED Controller, MDRC AKD-0424R.01
- AKD-0424V.01 RGBW LED Controller AKD-0424V.01
- AKH-0400.01 Heating actuator 4-fold, 2SU,24/230VAC AKH-0400.01
- AKH-0800.01 Heating actuator 8-fold, 4SU,24/230VAC AKH-0800.01
- AKK-01UP.01 Switch Actuator 1-fold, UP, 16A AKK-01UP.01
- AKK-0216.01 Switch Actuator 2-fold, 2SU, 16A AKK-0216.01
- AKK-0216.02 Switch Actuator 2-fold, 2SU, 16A AKK-0216.02
- AKK-02UP.01 Switch Actuator 2-fold, UP, 6A AKK-02UP.01
- AKK-03UP.01 Switch Actuator 3fold, FanCoil AKK-03UP.01