JAL-01UP.02 Shutter Actuator 1-fold, UP, 230VAC JAL-01UP.02
MDT technologies GmbH · Order number JAL-01UP.02 · Actuators › Shutter Actuator
for 230VAC shutter motors up to 300W
Download .knxprod Shutters and Blinds 1-fold 3.8 · 146 KB
Product
| Manufacturer | MDT technologies GmbH |
|---|---|
| Product name | JAL-01UP.02 Shutter Actuator 1-fold, UP, 230VAC |
| Order number | JAL-01UP.02 |
| Hardware | Jalousieaktor UP |
| Medium | Twisted Pair |
| Bus current (mA) | 10 |
| Rail mounted | No |
| Registration | Certified · 2018-08-23 |
| Languages | de-DE, en-US, es-ES, fr-FR |
| Catalog entry | M-0083_H-43-49_HP-002B-38-C067_CI-JAL.2D01UP.2E02-1 |
| Fingerprint | C067 |
| SHA-256 | 94c6b6ecdda75e3e9efacf59b4254ac2eb397140764c09f2695c5b5f9ee93540 |
| First seen | 2026-11-25 |
| Markets | 69 markets |
Application program: Shutters and Blinds 1-fold 3.8
| Application number | $002B |
|---|---|
| Version | 3.8 |
| Mask version | MV-0705 (7.5) |
| KNX Data Secure | No |
| Minimum ETS version | 4.0 |
| Parameters | 270 |
| Group objects | 103 |
Group objects (103)
| No | Name | Function | Size | DPT | Flags |
|---|---|---|---|---|---|
| 0 | Central function | Shutter up/down | 1 Bit | 1.8 up/down | CW |
| 1 | Central function | Slats adjustment / Stop | 1 Bit | 1.7 step | CW |
| 2 | Central function | Stop | 1 Bit | 1.17 trigger | CW |
| 3 | Central function | Absolute position | 1 Byte | 5.1 percentage (0..100%) | CW |
| 4 | Central function | Absolute position of slats | 1 Byte | 5.1 percentage (0..100%) | CW |
| 5 | Operation | Output | 1 Bit | 1.11 state | CRT |
| 6 | Central function | Rain alarm for ice protection | 1 Bit | 1.1 switch | CW |
| 7 | Dummy | 2 Bytes | |||
| 8 | Dummy | 2 Bytes | |||
| 9 | Dummy | 2 Bytes | |||
| 10 | Dummy | 2 Bytes | |||
| 11 | Dummy | 2 Bytes | |||
| 12 | Central function | Outdoor temperature | 2 Bytes | 9.1 temperature (°C) | CWTU |
| 13 | Dummy | 2 Bytes | |||
| 14 | Dummy | 2 Bytes | |||
| 15 | Automatic A | Automatic position 1 | 1 Bit | 1.1 switch | CW |
| 16 | Automatic A | Automatic position 2 | 1 Bit | 1.1 switch | CW |
| 17 | Automatic A | Automatic position 3 | 1 Bit | 1.1 switch | CW |
| 18 | Automatic A | Automatic position 4 | 1 Bit | 1.1 switch | CW |
| 19 | Automatic B | Automatic position 1 | 1 Bit | 1.1 switch | CW |
| 20 | Automatic B | Automatic position 2 | 1 Bit | 1.1 switch | CW |
| 21 | Automatic B | Automatic position 3 | 1 Bit | 1.1 switch | CW |
| 22 | Automatic B | Automatic position 4 | 1 Bit | 1.1 switch | CW |
| 23 | Channel A: {{5889}} | Shutter up/down | 1 Bit | 1.8 up/down | CW |
| 23 | Channel A: {{5888}} | Blinds up/down | 1 Bit | 1.8 up/down | CW |
| 23 | Channel A: {{5889}} | Single Object Control | 1 Bit | 1.8 up/down | CW |
| 24 | Channel A: {{5888}} | Slats adjustment / Stop | 1 Bit | 1.7 step | CW |
| 24 | Channel A: {{5889}} | Short term operation/Stop | 1 Bit | 1.8 up/down | CW |
| 25 | Channel A: {{5889}} | Stop | 1 Bit | 1.17 trigger | CW |
| 26 | Channel A: {{5889}} | Scene | 1 Byte | 17.1 scene number | CW |
| 26 | Channel A: {{5888}} | Scene | 1 Byte | 17.1 scene number | CW |
| 26 | Channel A: {{5888}} | Scene | 1 Byte | 18.1 scene control | CW |
| 26 | Channel A: {{5889}} | Scene | 1 Byte | 18.1 scene control | CW |
| 27 | Channel A: {{5889}} | Status current direction | 1 Bit | 1.8 up/down | CRT |
| 27 | Channel A: {{5888}} | Status current direction | 1 Bit | 1.8 up/down | CRT |
| 28 | Channel A: {{5889}} | Status of movement | 1 Bit | 1.11 state | CRT |
| 28 | Channel A: {{5889}} | Status of movement Up | 1 Bit | 1.11 state | CRT |
| 28 | Channel A: {{5888}} | Status of movement | 1 Bit | 1.11 state | CRT |
| 28 | Channel A: {{5888}} | Status of movement Up | 1 Bit | 1.11 state | CRT |
| 29 | Channel A: {{5889}} | Status of movement Down | 1 Bit | 1.11 state | CRT |
| 29 | Channel A: {{5888}} | Status of movement Down | 1 Bit | 1.11 state | CRT |
| 30 | Channel A: {{5889}} | Absolute position | 1 Byte | 5.1 percentage (0..100%) | CW |
| 30 | Channel A: {{5888}} | Absolute position | 1 Byte | 5.1 percentage (0..100%) | CW |
| 31 | Channel A: {{5888}} | Absolute position of slats | 1 Byte | 5.1 percentage (0..100%) | CW |
| 32 | Channel A: {{5889}} | Status current position | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 32 | Channel A: {{5888}} | Status current position | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 33 | Channel A: {{5888}} | Status cur. position of slats | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 34 | Channel A: {{5889}} | Status Lock/Alarms | 1 Bit | 1.11 state | CRT |
| 34 | Channel A: {{5888}} | Status Lock/Alarms | 1 Bit | 1.11 state | CRT |
| 35 | Channel A: {{5889}} | Start reference drive | 1 Bit | 1.8 up/down | CW |
| 35 | Channel A: {{5888}} | Start reference drive | 1 Bit | 1.8 up/down | CW |
| 36 | Channel A: {{5889}} | move to position | 1 Bit | 1.1 switch | CW |
| 36 | Channel A: {{5888}} | move to position | 1 Bit | 1.1 switch | CW |
| 37 | Channel A: {{5889}} | Status upper Position | 1 Bit | 1.11 state | CRT |
| 37 | Channel A: {{5888}} | Status upper Position | 1 Bit | 1.11 state | CRT |
| 38 | Channel A: {{5889}} | Status lower Position | 1 Bit | 1.11 state | CRT |
| 38 | Channel A: {{5888}} | Status lower Position | 1 Bit | 1.11 state | CRT |
| 39 | Channel A: {{5889}} | Block central object | 1 Bit | 1.3 enable | CW |
| 39 | Channel A: {{5888}} | Block central object | 1 Bit | 1.3 enable | CW |
| 39 | Channel A: {{5888}} | Block central object | 1 Bit | 1.3 enable | CRWT |
| 39 | Channel A: {{5889}} | Block central object | 1 Bit | 1.3 enable | CRWT |
| 40 | Channel A: {{5888}} | Block absolute position | 1 Bit | 1.3 enable | CW |
| 40 | Channel A: {{5889}} | Block absolute position | 1 Bit | 1.3 enable | CW |
| 40 | Channel A: {{5888}} | Block absolute position | 1 Bit | 1.3 enable | CRWT |
| 40 | Channel A: {{5889}} | Block absolute position | 1 Bit | 1.3 enable | CRWT |
| 41 | Channel A: {{5889}} | Block functions | 1 Bit | 1.3 enable | CW |
| 41 | Channel A: {{5888}} | Block functions | 1 Bit | 1.3 enable | CW |
| 41 | Channel A: {{5888}} | Block functions | 1 Bit | 1.3 enable | CRWT |
| 41 | Channel A: {{5889}} | Block functions | 1 Bit | 1.3 enable | CRWT |
| 42 | Channel A: {{5889}} | Wind alarm | 1 Bit | 1.5 alarm | CW |
| 42 | Channel A: {{5888}} | Wind alarm | 1 Bit | 1.5 alarm | CW |
| 43 | Channel A: {{5889}} | Rain alarm | 1 Bit | 1.5 alarm | CW |
| 43 | Channel A: {{5888}} | Rain alarm | 1 Bit | 1.5 alarm | CW |
| 43 | Channel A: {{5888}} | Fire alarm | 1 Bit | 1.5 alarm | CW |
| 43 | Channel A: {{5889}} | Fire alarm | 1 Bit | 1.5 alarm | CW |
| 44 | Channel A: {{5889}} | Frost alarm | 1 Bit | 1.5 alarm | CW |
| 44 | Channel A: {{5888}} | Frost alarm | 1 Bit | 1.5 alarm | CW |
| 45 | Channel A: {{5889}} | Block | 1 Bit | 1.3 enable | CW |
| 45 | Channel A: {{5888}} | Block | 1 Bit | 1.3 enable | CW |
| 46 | Channel A: {{5888}} | Window contact | 1 Bit | 1.2 boolean | CWTU |
| 46 | Channel A: {{5888}} | Window contact 1 | 1 Bit | 1.2 boolean | CWTU |
| 46 | Channel A: {{5889}} | Window contact | 1 Bit | 1.2 boolean | CWTU |
| 46 | Channel A: {{5889}} | Window contact 1 | 1 Bit | 1.2 boolean | CWTU |
| 47 | Channel A: {{5888}} | Window contact 2 | 1 Bit | 1.2 boolean | CWTU |
| 47 | Channel A: {{5889}} | Window contact 2 | 1 Bit | 1.2 boolean | CWTU |
| 48 | Channel A: {{5888}} | Room temperature | 2 Bytes | 9.1 temperature (°C) | CW |
| 48 | Channel A: {{5889}} | Room temperature | 2 Bytes | 9.1 temperature (°C) | CW |
| 48 | Channel A: {{5889}} | Room temperature threshold | 1 Bit | 1.1 switch | CW |
| 48 | Channel A: {{5888}} | Room temperature threshold | 1 Bit | 1.1 switch | CW |
| 48 | Channel A: {{5888}} | control value for heating | 1 Byte | 5.1 percentage (0..100%) | CW |
| 48 | Channel A: {{5889}} | control value for heating | 1 Byte | 5.1 percentage (0..100%) | CW |
| 49 | Channel A: {{5888}} | Block Shading | 1 Bit | 1.3 enable | CW |
| 49 | Channel A: {{5888}} | Enable Shading | 1 Bit | 1.1 switch | CW |
| 49 | Channel A: {{5888}} | Block slat tracking | 1 Bit | 1.3 enable | CW |
| 49 | Channel A: {{5888}} | Enable slat tracking | 1 Bit | 1.1 switch | CW |
| 49 | Channel A: {{5889}} | Block Shading | 1 Bit | 1.3 enable | CW |
| 49 | Channel A: {{5889}} | Enable Shading | 1 Bit | 1.1 switch | CW |
| 50 | Channel A: {{5888}} | Status Shading state | 1 Bit | 1.11 state | CRT |
| 50 | Channel A: {{5889}} | Status Shading state | 1 Bit | 1.11 state | CRT |
| 50 | Channel A: {{5888}} | Status Shading ready | 1 Bit | 1.11 state | CRT |
| 50 | Channel A: {{5889}} | Status Shading ready | 1 Bit | 1.11 state | CRT |
| 51 | Channel A: {{5889}} | Diagnosis text | 14 Bytes | 16.0 Character String (ASCII) | CRT |
| 51 | Channel A: {{5888}} | Diagnosis text | 14 Bytes | 16.0 Character String (ASCII) | CRT |
Parameters (181)
| Parameter | Type | Default |
|---|---|---|
| Channel A | list | Shutter |
| Movement time | unsignedInt 1…1000 | 45 |
| Step time for slets adjustment | unsignedInt 50…5000 | 200 |
| Slat adjustment time | unsignedInt 100…10000 | 1200 |
| Pause on reverse | unsignedInt 100…2000 | 1000 |
| Switch-on delay motor | list | 200 ms |
| Switch-off delay motor | list | 200 ms |
| Extension of movement time | list | 5% |
| Position of slats at end of movement (down) | list | 100% |
| Block manual operation on the device | list | not active |
| Objects for absolute position | list | not active |
| Action after reference drive | list | no action |
| 1Bit object for "Move to position" | list | not active |
| Central objects | list | only absolute position and Up/Down |
| Scene | list | not active |
| Automatic functions | list | not active |
| Air function over window contacts | list | not active |
| Alarm order | list | Wind alarm, Rain alarm, Frost alarm, Block function |
| Action on reset of alarm | list | not active |
| Wind alarm | list | not active |
| Monitoring time (0 = not active) | unsignedInt 0…120 | 0 |
| Action on wind alarm | list | not active |
| Rain alarm | list | not active |
| Action on rain alarm | list | not active |
| Action on fire alarm | list | not active |
| Frost alarm | list | not active |
| Action on frost alarm | list | not active |
| Advanced function | list | not active |
| Action on block (value=1) | list | not active |
| Save scenes | list | not active |
| Scene A - Height position | list | not active |
| Scene Number A | list | not active |
| Scene A - Position of slats | list | not active |
| Scene B - Height position | list | not active |
| Scene Number B | list | not active |
| Scene C - Height position | list | not active |
| Scene B - Position of slats | list | not active |
| Scene Number C | list | not active |
| Scene D - Height position | list | not active |
| Scene Number D | list | not active |
| Scene C - Position of slats | list | not active |
| Scene E - Height position | list | not active |
| Scene Number E | list | not active |
| Scene F - Height position | list | not active |
| Scene D - Position of slats | list | not active |
| Scene Number F | list | not active |
| Scene G - Height position | list | not active |
| Scene Number G | list | not active |
| Scene E - Position of slats | list | not active |
| Scene H - Height position | list | not active |
| Scene Number H | list | not active |
| Scene F - Position of slats | list | not active |
| Scene G - Position of slats | list | not active |
| Scene H - Position of slats | list | not active |
| Used Automatic objects | list | Block A |
| Height position | list | not active |
| Slat position | list | not active |
| Automatic Block A | list | not active |
| Object "Block functions" | list | not active |
| Block "Up/Down" (also Central) | list | not active |
| Block "Automatic positions" | list | not active |
| Block "Absolute position" (also Central) | list | not active |
| Block "Scene" | list | not active |
| "Block absolute position" with Up/Down | list | not active |
| Time for Up/Down movement | list | same |
| Time for Up movement | unsignedInt 1…1000 | 45 |
| Time for Down movement | unsignedInt 1…1000 | 45 |
| Status current direction / position up/down | list | not active |
| Short term operation (Key operation for exact position) | list | not active |
| Movement time for short term operation | unsignedInt 50…5000 | 200 |
| Cancel block when position is 0% | list | not active |
| Move to position (value = 1) | list | always |
| Action at withdrawal of automatic position (value = 0) | list | not active |
| Object for reference drive | list | not active |
| Action on value = 1 | list | move to position |
| Action on value = 0 (only if position valid) | list | no function |
| Shutter position | list | 50% |
| Position of blinds | list | 50% |
| Slat position | list | 100% |
| Automatic Block B | list | not active |
| Scene A - block/enable functions | list | not active |
| Scene B - block/enable functions | list | not active |
| Scene C - block/enable functions | list | not active |
| Scene D - block/enable functions | list | not active |
| Scene E - block/enable functions | list | not active |
| Scene F - block/enable functions | list | not active |
| Scene G - block/enable functions | list | not active |
| Scene H - block/enable functions | list | not active |
| Startup time | unsignedInt 2…240 | 2 |
| Send "Operation" cyclically | list | not active |
| Overwrite learned scenes | list | load parameter |
| Up/Down movement can stop (Single Object Control) | list | not active |
| Interchange connections for motor Up/Down | list | normal |
| Automatic clouding | list | not active |
| Normal blocking function | list | not active |
| Action on reset of block | list | not active |
| Height position on alarm/block | list | 0% |
| Slat position on alarm/block | list | 0% |
| Block "Air function" | list | not active |
| Object "Block central objects" | list | not active |
| "Block central objects" with "Down" | list | not active |
| Cancel "Block central object" when position is 0% | list | not active |
| Automatic position 1 | list | not active |
| Automatic position 2 | list | not active |
| Automatic position 3 | list | not active |
| Automatic position 4 | list | not active |
| Window contacts | list | 1 contact for "open" window |
| Status current position | list | not active |
| Diagnosis in plaintext | list | send at request |
| Behavior on bus power return | list | no action |
| Object "Block absolute position" | list | not active |
| Object for movement status | list | not active |
| Value for "open" | list | value 1 |
| Value for "open" | list | contact 1 = "1" / contact 2 = "1" |
| Value for "tilted" | list | contact 1 = "0" / contact 2 = "1" |
| Action when window is "open" | list | move to position if lower |
| Height position for "open" | list | 0% |
| Action when window is "tilted" | list | move to position if down |
| Slat position for "open" | list | 0% |
| Height position for "tilted" | list | 90% |
| Slat position for "tilted" | list | 70% |
| Action when window is closed: make up for central telegrams, otherwise,,, | list | move to former position |
| Compass direction | list | south |
| from | list | 30° (default) |
| from | list | 75° (default) |
| from | list | 120° (default) |
| from | list | 165° (default) |
| from | list | 210° (default) |
| to | list | 150° (default) |
| to | list | 195° (default) |
| to | list | 240° (default) |
| to | list | 285° (default) |
| to | list | 330° (default) |
| from | unsignedInt 0…45 | 2 |
| to | unsignedInt 10…90 | 90 |
| Delay until Shading On | unsignedInt 0…30 | 2 |
| Delay until Shading Off | unsignedInt 0…60 | 20 |
| Release via (temperature/control value) | list | not active |
| Release when temperature greater than | unsignedInt 15…35 | 21 |
| Release when temperature threshold is equal to | list | value 1 |
| Status Automatic Shading | list | not active |
| Action at brightness threshold 1 | list | active |
| Action at brightness threshold 2 | list | active |
| Behavior after Shading | list | no change |
| Shading from brightness threshold | list | brightness threshold 1 |
| Slat is horizontal at | list | 50% |
| Start slat tracking when elevation is less than (0 = not active) | unsignedInt 0…90 | 45 |
| Minimum change of slat tracking | list | 10% |
| Status for current lock/alarms | list | not active |
| Behavior after bus power down | list | no action |
| to | list | 300° (default) |
| from | list | 60° (default) |
| Offset slat tracking | signedInt -25…25 | 0 |
| Object Clouding | list | enable at value 1 |
| Release when control value for heating less than | list | 5% |
| Behavior when window is "opened" | list | execute air function |
| Enable "Shading" with positon 0%, after blocking with Up/Down | list | active |
| Send status | list | after movement has stopped |
| Action when window is closed | list | move to former position |
| Object sends status | list | not active |
| Object sends state (from HW R5.0) | list | not active |
| Fire alarm | list | not active |
| Advanced ice/frost protaction (from HW R5.2) | list | not active |
| Evaluate rain | list | not active |
| End of alarm when the outdoor temperature is higher than | list | 5 °C |
| Alarm end delay | unsignedInt 0…240 | 2 |
| Monitoring time for outdoor temperature and rain | list | not active |
| Automatic Shading | list | not active |
| Monitoring time for outdoor temperature | list | not active |
| Additional text | text | |
| Action at brightness threshold 1 | list | move to position |
| Action at brightness threshold 2 | list | no change |
| Position of blinds | list | 100% |
| Shutter position 1 | list | 100% |
| Shutter position 2 | list | 60% |
| Slat position | list | 50% |
| Scene selection | list | Scene A |
| Action at brightness threshold | list | no Automatic Shading |
| Description of channels/objects | text | |
| Shading | list | enabled |
| Action when tilted window is closed | list | move to former position |
Version history
| Application | App no | Fingerprint | First seen | Size | File |
|---|---|---|---|---|---|
| Shutters and Blinds 1-fold 3.8 latest | $002B | C067 | 2026-11-25 | 146 KB | Download |
About this file
This is the official ETS product database for the MDT technologies GmbH JAL-01UP.02 Shutter Actuator 1-fold, UP, 230VAC (JAL-01UP.02), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.
More from MDT technologies GmbH
- Analog I/O 2fold, flush mounted AIO-0210V.01
- Analog I/O 4fold, MDRC AIO-0410V.01
- AKD-0103.01 Dimming actuator 1-f, 4TE, 230VAC,600W AKD-0103.01
- AKD-0201.01 Dimming actuator 2-f, 4TE, 230VAC,250W AKD-0201.01
- AKD-0201.02 Dimming Actuator 2-fold AKD-0201.02
- AKD-0203.01 Dimming actuator 2-f, 8TE, 230VAC,600W AKD-0203.01
- AKD-0224V.02 LED Controler 2 Ch AKD-0224V.02
- AKD-0230CC.02 LED Controller CC/CV 30 W / 230 V 2-channel AKD-0230CC.02
- AKD-0260CC.02 LED Controller CC/CV 60 W / 230 V 2-channel AKD-0260CC.02
- AKD-0324V.02 LED Controler 3 Ch/RGB AKD-0324V.02
- AKD-0401.01 Dimming actuator 4-f, 8TE, 230VAC,250W AKD-0401.01
- AKD-0401.02 Dimming Actuator 4-fold AKD-0401.02