AMI-0416.02 Switch Actuator with current measurement 4-fold, 4SU, 16/20A AMI-0416.02
MDT technologies GmbH · Order number AMI-0416.02 · Actuators › Switch Actuators with current measurment
Industrial version 230VAC, 16/20A, 200µF C-Load
Download .knxprod Switching, Staircase lighting, Meter current 4f 2.2 · 113 KB
Product
| Manufacturer | MDT technologies GmbH |
|---|---|
| Product name | AMI-0416.02 Switch Actuator with current measurement 4-fold, 4SU, 16/20A |
| Order number | AMI-0416.02 |
| Hardware | Schaltaktor mit Strommesung 4-fach |
| Medium | Twisted Pair |
| Bus current (mA) | 10 |
| Rail mounted | Yes |
| Width (mm) | 71.3 |
| Registration | Certified · 2016-09-21 |
| Languages | de-DE, en-US |
| Catalog entry | M-0083_H-8-2_HP-0018-22-2475_CI-AMI.2D0416.2E02-1 |
| Fingerprint | 2475 |
| SHA-256 | fbf516959430be15b903d6d55d0e3cd61f2cccfce8ee0eed3e301fd7a81894c1 |
| First seen | 2026-11-25 |
| Markets | 69 markets |
Application program: Switching, Staircase lighting, Meter current 4f 2.2
| Application number | $0018 |
|---|---|
| Version | 2.2 |
| Mask version | MV-0701 (7.1) |
| KNX Data Secure | No |
| Minimum ETS version | 4.0 |
| Parameters | 452 |
| Group objects | 131 |
Group objects (131)
| No | Name | Function | Size | DPT | Flags |
|---|---|---|---|---|---|
| 0 | Channel A: {{144}} | Switch On/Off | 1 Bit | 1.1 switch | CW |
| 1 | Channel A: {{144}} | Staircase lighting | 1 Bit | 1.1 switch | CW |
| 2 | Channel A: {{144}} | Block | 1 Bit | 1.3 enable | CW |
| 3 | Channel A: {{144}} | Forced | 2 Bit | 2.1 switch control | CW |
| 4 | Channel A: {{144}} | Scene | 1 Byte | 17.1 scene number | CW |
| 4 | Channel A: {{144}} | Scene | 1 Byte | 18.1 scene control | CW |
| 5 | Channel A: {{144}} | State | 1 Bit | 1.11 state | CRT |
| 6 | Channel A: {{144}} | Logic 1 | 1 Bit | 1.2 boolean | CW |
| 7 | Channel A: {{144}} | Logic 2 | 1 Bit | 1.2 boolean | CW |
| 8 | Channel A: {{144}} | Response operating hours | 4 Bytes | 13.100 time lag (s) | CRT |
| 8 | Channel A: {{144}} | Time to the next service | 4 Bytes | 13.100 time lag (s) | CRT |
| 8 | Channel A: {{144}} | Response operating hours | 2 Bytes | 7.7 time (h) | CRT |
| 8 | Channel A: {{144}} | Time to the next service | 2 Bytes | 7.7 time (h) | CRT |
| 9 | Channel A: {{144}} | Reset operating hour | 1 Bit | 1.3 enable | CW |
| 9 | Channel A: {{144}} | Reset service | 1 Bit | 1.3 enable | CW |
| 10 | Channel A: {{144}} | Service required | 1 Bit | 1.11 state | CRT |
| 11 | Channel A: {{144}} | Current value | 2 Bytes | 7.12 current (mA) | CRT |
| 11 | Channel A: {{144}} | Current value | 2 Bytes | 9.21 current (mA) | CRT |
| 11 | Channel A: {{144}} | Current value | 4 Bytes | 14.19 electric current (A) | CRT |
| 11 | Channel A: {{144}} | Power value | 2 Bytes | 9.24 power (kW) | CRT |
| 11 | Channel A: {{144}} | Power value | 4 Bytes | 14.56 power (W) | CRT |
| 12 | Channel A: {{144}} | Exceedance of load | 1 Bit | 1.11 state | CRT |
| 13 | Channel A: {{144}} | Lower deviation of load | 1 Bit | 1.11 state | CRT |
| 14 | Channel A: {{144}} | Load faulty | 1 Bit | 1.5 alarm | CRT |
| 14 | Channel A: {{144}} | Fault current | 1 Bit | 1.5 alarm | CRT |
| 14 | Channel A: {{144}} | Fault current/Load faulty | 1 Bit | 1.5 alarm | CRT |
| 15 | Channel A: {{144}} | Reset power meter | 1 Bit | 1.3 enable | CW |
| 16 | Channel A: {{144}} | Theoretical watt hour (Wh) | 4 Bytes | 13.10 active energy (Wh) | CRT |
| 16 | Channel A: {{144}} | Theoretical kilowatt hour (kWh) | 4 Bytes | 13.13 active energy (kWh) | CRT |
| 17 | Dummy | 1 Bit | CRT | ||
| 18 | Channel B: {{580}} | Switch On/Off | 1 Bit | 1.1 switch | CW |
| 19 | Channel B: {{580}} | Staircase lighting | 1 Bit | 1.1 switch | CW |
| 20 | Channel B: {{580}} | Block | 1 Bit | 1.3 enable | CW |
| 21 | Channel B: {{580}} | Forced | 2 Bit | 2.1 switch control | CW |
| 22 | Channel B: {{580}} | Scene | 1 Byte | 17.1 scene number | CW |
| 22 | Channel B: {{580}} | Scene | 1 Byte | 18.1 scene control | CW |
| 23 | Channel B: {{580}} | State | 1 Bit | 1.11 state | CRT |
| 24 | Channel B: {{580}} | Logic 1 | 1 Bit | 1.2 boolean | CW |
| 25 | Channel B: {{580}} | Logic 2 | 1 Bit | 1.2 boolean | CW |
| 26 | Channel B: {{580}} | Response operating hours | 4 Bytes | 13.100 time lag (s) | CRT |
| 26 | Channel B: {{580}} | Time to the next service | 4 Bytes | 13.100 time lag (s) | CRT |
| 26 | Channel B: {{580}} | Response operating hours | 2 Bytes | 7.7 time (h) | CRT |
| 26 | Channel B: {{580}} | Time to the next service | 2 Bytes | 7.7 time (h) | CRT |
| 27 | Channel B: {{580}} | Reset operating hour | 1 Bit | 1.3 enable | CW |
| 27 | Channel B: {{580}} | Reset service | 1 Bit | 1.3 enable | CW |
| 28 | Channel B: {{580}} | Service required | 1 Bit | 1.11 state | CRT |
| 29 | Channel B: {{580}} | Current value | 2 Bytes | 7.12 current (mA) | CRT |
| 29 | Channel B: {{580}} | Current value | 2 Bytes | 9.21 current (mA) | CRT |
| 29 | Channel B: {{580}} | Current value | 4 Bytes | 14.19 electric current (A) | CRT |
| 29 | Channel B: {{580}} | Power value | 2 Bytes | 9.24 power (kW) | CRT |
| 29 | Channel B: {{580}} | Power value | 4 Bytes | 14.56 power (W) | CRT |
| 30 | Channel B: {{580}} | Exceedance of load | 1 Bit | 1.11 state | CRT |
| 31 | Channel B: {{580}} | Lower deviation of load | 1 Bit | 1.11 state | CRT |
| 32 | Channel B: {{580}} | Fault current | 1 Bit | 1.5 alarm | CRT |
| 32 | Channel B: {{580}} | Load faulty | 1 Bit | 1.5 alarm | CRT |
| 32 | Channel B: {{580}} | Fault current/Load faulty | 1 Bit | 1.5 alarm | CRT |
| 33 | Channel B: {{580}} | Reset power meter | 1 Bit | 1.3 enable | CW |
| 34 | Channel B: {{580}} | Theoretical watt hour (Wh) | 4 Bytes | 13.10 active energy (Wh) | CRT |
| 34 | Channel B: {{580}} | Theoretical kilowatt hour (kWh) | 4 Bytes | 13.13 active energy (kWh) | CRT |
| 35 | Dummy | 1 Bit | CRT | ||
| 36 | Channel C: {{646}} | Switch On/Off | 1 Bit | 1.1 switch | CW |
| 37 | Channel C: {{646}} | Staircase lighting | 1 Bit | 1.1 switch | CW |
| 38 | Channel C: {{646}} | Block | 1 Bit | 1.3 enable | CW |
| 39 | Channel C: {{646}} | Forced | 2 Bit | 2.1 switch control | CW |
| 40 | Channel C: {{646}} | Scene | 1 Byte | 17.1 scene number | CW |
| 40 | Channel C: {{646}} | Scene | 1 Byte | 18.1 scene control | CW |
| 41 | Channel C: {{646}} | State | 1 Bit | 1.11 state | CRT |
| 42 | Channel C: {{646}} | Logic 1 | 1 Bit | 1.2 boolean | CW |
| 43 | Channel C: {{646}} | Logic 2 | 1 Bit | 1.2 boolean | CW |
| 44 | Channel C: {{646}} | Response operating hours | 4 Bytes | 13.100 time lag (s) | CRT |
| 44 | Channel C: {{646}} | Time to the next service | 4 Bytes | 13.100 time lag (s) | CRT |
| 44 | Channel C: {{646}} | Response operating hours | 2 Bytes | 7.7 time (h) | CRT |
| 44 | Channel C: {{646}} | Time to the next service | 2 Bytes | 7.7 time (h) | CRT |
| 45 | Channel C: {{646}} | Reset operating hour | 1 Bit | 1.3 enable | CW |
| 45 | Channel C: {{646}} | Reset service | 1 Bit | 1.3 enable | CW |
| 46 | Channel C: {{646}} | Service required | 1 Bit | 1.11 state | CRT |
| 47 | Channel C: {{646}} | Current value | 2 Bytes | 7.12 current (mA) | CRT |
| 47 | Channel C: {{646}} | Current value | 2 Bytes | 9.21 current (mA) | CRT |
| 47 | Channel C: {{646}} | Current value | 4 Bytes | 14.19 electric current (A) | CRT |
| 47 | Channel C: {{646}} | Power value | 2 Bytes | 9.24 power (kW) | CRT |
| 47 | Channel C: {{646}} | Power value | 4 Bytes | 14.56 power (W) | CRT |
| 48 | Channel C: {{646}} | Exceedance of load | 1 Bit | 1.11 state | CRT |
| 49 | Channel C: {{646}} | Lower deviation of load | 1 Bit | 1.11 state | CRT |
| 50 | Channel C: {{646}} | Fault current | 1 Bit | 1.5 alarm | CRT |
| 50 | Channel C: {{646}} | Load faulty | 1 Bit | 1.5 alarm | CRT |
| 50 | Channel C: {{646}} | Fault current/Load faulty | 1 Bit | 1.5 alarm | CRT |
| 51 | Channel C: {{646}} | Reset power meter | 1 Bit | 1.3 enable | CW |
| 52 | Channel C: {{646}} | Theoretical watt hour (Wh) | 4 Bytes | 13.10 active energy (Wh) | CRT |
| 52 | Channel C: {{646}} | Theoretical kilowatt hour (kWh) | 4 Bytes | 13.13 active energy (kWh) | CRT |
| 53 | Dummy | 1 Bit | CRT | ||
| 54 | Channel D: {{652}} | Switch On/Off | 1 Bit | 1.1 switch | CW |
| 55 | Channel D: {{652}} | Staircase lighting | 1 Bit | 1.1 switch | CW |
| 56 | Channel D: {{652}} | Block | 1 Bit | 1.3 enable | CW |
| 57 | Channel D: {{652}} | Forced | 2 Bit | 2.1 switch control | CW |
| 58 | Channel D: {{652}} | Scene | 1 Byte | 17.1 scene number | CW |
| 58 | Channel D: {{652}} | Scene | 1 Byte | 18.1 scene control | CW |
| 59 | Channel D: {{652}} | State | 1 Bit | 1.11 state | CRT |
| 60 | Channel D: {{652}} | Logic 1 | 1 Bit | 1.2 boolean | CW |
| 61 | Channel D: {{652}} | Logic 2 | 1 Bit | 1.2 boolean | CW |
| 62 | Channel D: {{652}} | Response operating hours | 4 Bytes | 13.100 time lag (s) | CRT |
| 62 | Channel D: {{652}} | Time to the next service | 4 Bytes | 13.100 time lag (s) | CRT |
| 62 | Channel D: {{652}} | Response operating hours | 2 Bytes | 7.7 time (h) | CRT |
| 62 | Channel D: {{652}} | Time to the next service | 2 Bytes | 7.7 time (h) | CRT |
| 63 | Channel D: {{652}} | Reset operating hour | 1 Bit | 1.3 enable | CW |
| 63 | Channel D: {{652}} | Reset service | 1 Bit | 1.3 enable | CW |
| 64 | Channel D: {{652}} | Service required | 1 Bit | 1.11 state | CRT |
| 65 | Channel D: {{652}} | Current value | 2 Bytes | 7.12 current (mA) | CRT |
| 65 | Channel D: {{652}} | Current value | 2 Bytes | 9.21 current (mA) | CRT |
| 65 | Channel D: {{652}} | Current value | 4 Bytes | 14.19 electric current (A) | CRT |
| 65 | Channel D: {{652}} | Power value | 2 Bytes | 9.24 power (kW) | CRT |
| 65 | Channel D: {{652}} | Power value | 4 Bytes | 14.56 power (W) | CRT |
| 66 | Channel D: {{652}} | Exceedance of load | 1 Bit | 1.11 state | CRT |
| 67 | Channel D: {{652}} | Lower deviation of load | 1 Bit | 1.11 state | CRT |
| 68 | Channel D: {{652}} | Fault current | 1 Bit | 1.5 alarm | CRT |
| 68 | Channel D: {{652}} | Load faulty | 1 Bit | 1.5 alarm | CRT |
| 68 | Channel D: {{652}} | Fault current/Load faulty | 1 Bit | 1.5 alarm | CRT |
| 69 | Channel D: {{652}} | Reset power meter | 1 Bit | 1.3 enable | CW |
| 70 | Channel D: {{652}} | Theoretical watt hour (Wh) | 4 Bytes | 13.10 active energy (Wh) | CRT |
| 70 | Channel D: {{652}} | Theoretical kilowatt hour (kWh) | 4 Bytes | 13.13 active energy (kWh) | CRT |
| 71 | Dummy | 1 Bit | CRT | ||
| 72 | Central function | Switch On/Off | 1 Bit | 1.1 switch | CW |
| 73 | Central function | Operating | 1 Bit | 1.11 state | CRT |
| 74 | Central function | Manual control | 1 Bit | 1.1 switch | CW |
| 75 | Central function | Exceedance of total load | 1 Bit | 1.1 switch | CRT |
| 76 | Central function | Value of total current | 2 Bytes | 9.21 current (mA) | CRT |
| 76 | Central function | Value of total current | 4 Bytes | 14.19 electric current (A) | CRT |
| 76 | Central function | Total power value | 2 Bytes | 9.24 power (kW) | CRT |
| 76 | Central function | Total power value | 4 Bytes | 14.56 power (W) | CRT |
| 77 | Central function | Total watt hour (Wh) | 4 Bytes | 13.10 active energy (Wh) | CRT |
| 77 | Central function | Total kilowatt hour (kWh) | 4 Bytes | 13.13 active energy (kWh) | CRT |
| 78 | Dummy | 1 Bit | CRWTU |
Parameters (79)
| Parameter | Type | Default |
|---|---|---|
| Startup timeout | list | 1 s |
| Time for Staircase lighting | unsignedInt 0…30000 | 0 |
| Mode | list | normaly opend |
| Prewarning time | unsignedInt 0…30000 | 0 |
| Prewarning | list | not active |
| Manual switching off | list | not active |
| Warning time | unsignedInt 0…30000 | 1 |
| On delay | unsignedInt 0…30000 | 0 |
| Extend Staircase lighting time | list | not active |
| Off delay | unsignedInt 0…30000 | 0 |
| Send status cyclic | list | no send cyclic |
| Central function | list | not active |
| Save scene | list | disabled |
| Scene behaviour | list | Off |
| Behaviour when locked | list | no change |
| Behaviour when unlocked | list | no change |
| Behaviour at bus power up | list | no change |
| Behaviour at bus power down | list | no change |
| Logic functions | list | not active |
| Logic operation | list | OR |
| Scene | list | not active |
| operating hours counter | list | not active |
| Type of operating hours counter | list | operating hours counter |
| Count if | list | relay ON |
| Send status of operating hours every (0= not active) | unsignedInt 0…10000 | 0 |
| Send signal of service at … intervals | unsignedInt 0…250 | 0 |
| Current measurement | list | not active |
| Object selection for the current measurement | list | value in mA (DPT 7.012) |
| Add the channel to total current measurement | list | not active |
| Send current value after changes value | list | not active |
| Cyclic sending | list | not active |
| Hysteresis after exceeding | unsignedInt 10…100 | 10 |
| Send telegram | list | send no telegramm |
| Behavior after exceeding | list | send no telegramm |
| Send exceeding cyclical | list | not active |
| Hysteresis after lower deviation | unsignedInt 10…100 | 10 |
| Behavior after lower deviation | list | send no telegramm |
| Send lower deviation cyclical | list | not active |
| Error message | list | not active |
| Switching threshold | list | 20 mA |
| Total current | list | not active |
| Object selection for the current measurement | list | floating value in mA (DPT 9.021) |
| Behavior at exceeding | list | send no telegramm |
| Send status of service hours every (0 = not active) | unsignedInt 0…10000 | 0 |
| Monitoring exceedance of load | list | not active |
| Value for load monitoring | unsignedInt 1…200 | 1 |
| Monitoring lower deviation of load | list | not active |
| Scene A | list | Off |
| Factor for conversion into theoretical wattage kW: Current value x Factor | unsignedInt 100…250 | 230 |
| Cyclical sending of "Operation"-telegram | list | no send |
| Block object | list | not active |
| Manual control | list | block via Object (Value 1 = not active) |
| Power meter function (Wh/kWh) | list | not active |
| Sending object value | list | only request |
| Set object for power meter | list | value in Wh (DPT 13.010) |
| Total power meter (Wh/kWh) (Sum of activated power meter for each channel) | list | not active |
| Object selection for total power meter | list | value in Wh (DPT 13.010) |
| Memory of all power meters set to 0 after download of application | list | no |
| Value range for load monitoring | list | 100mA - 20A |
| Value for load monitoring | list | 50 mA |
| Eco mode, switch LED's off after | list | not active |
| Channel A | list | switching output |
| Channel B | list | switching output |
| Channel C | list | switching output |
| Channel D | list | switching output |
| Select data type | list | 4Byte value in s (DPT 13.100) |
| Switch channel off | list | no action |
| Time delay | list | 0 s |
| Scene A | list | not active |
| Scene number | list | 1 |
| Scene B | list | not active |
| Scene C | list | not active |
| Scene D | list | not active |
| Scene E | list | not active |
| Scene F | list | not active |
| Scene G | list | not active |
| Scene H | list | not active |
| Description of channel/objects | text | |
| Additional text | text |
Version history
| Application | App no | Fingerprint | First seen | Size | File |
|---|---|---|---|---|---|
| Switching, Staircase lighting, Meter current 4f 2.2 latest | $0018 | 2475 | 2026-11-25 | 113 KB | Download |
About this file
This is the official ETS product database for the MDT technologies GmbH AMI-0416.02 Switch Actuator with current measurement 4-fold, 4SU, 16/20A (AMI-0416.02), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.
More from MDT technologies GmbH
- Analog I/O 2fold, flush mounted AIO-0210V.01
- Analog I/O 4fold, MDRC AIO-0410V.01
- AKD-0103.01 Dimming actuator 1-f, 4TE, 230VAC,600W AKD-0103.01
- AKD-0201.01 Dimming actuator 2-f, 4TE, 230VAC,250W AKD-0201.01
- AKD-0201.02 Dimming Actuator 2-fold AKD-0201.02
- AKD-0203.01 Dimming actuator 2-f, 8TE, 230VAC,600W AKD-0203.01
- AKD-0224V.02 LED Controler 2 Ch AKD-0224V.02
- AKD-0230CC.02 LED Controller CC/CV 30 W / 230 V 2-channel AKD-0230CC.02
- AKD-0260CC.02 LED Controller CC/CV 60 W / 230 V 2-channel AKD-0260CC.02
- AKD-0324V.02 LED Controler 3 Ch/RGB AKD-0324V.02
- AKD-0401.01 Dimming actuator 4-f, 8TE, 230VAC,250W AKD-0401.01
- AKD-0401.02 Dimming Actuator 4-fold AKD-0401.02