AKK-03UP.01 Switch Actuator 3fold, FanCoil AKK-03UP.01

MDT technologies GmbH · Order number AKK-03UP.01 · Archive › Actuators › Switch Actuators, FanCoil

Compact version 230VAC, 10A ohmic load

Download .knxprod Switch, Staircase 3fold, FanCoil 1.0 · 102 KB

Product

ManufacturerMDT technologies GmbH
Product nameAKK-03UP.01 Switch Actuator 3fold, FanCoil
Order numberAKK-03UP.01
HardwareSchaltaktor, FainCoil
MediumTwisted Pair
Bus current (mA)18
Rail mountedNo
RegistrationRegistered · 2015-06-29
Languagesde-DE, en-US
Catalog entryM-0083_H-28-0_HP-001A-10-7B3F_CI-AKK.2D03UP.2E01-2
Fingerprint7B3F
SHA-256bcac4b7b58feb732d82aec9a7266f33bd1d76aff03505499534b6351e7a4fa82
First seen2026-11-25
Markets69 markets

Application program: Switch, Staircase 3fold, FanCoil 1.0

Application number$001A
Version1.0
Mask versionMV-0701 (7.1)
KNX Data SecureNo
Minimum ETS version4.0
Parameters222
Group objects79
Group objects (79)
NoNameFunctionSizeDPTFlags
0Channel ASwitch On/Off1 Bit1.1 switchCW
0Additional fanEnable additional fan1 Bit1.1 switchCW
1Channel AStaircase1 Bit1.1 switchCW
1Switching Auto/Manual1=Automatic / 0 = Manual1 Bit1.1 switchCRWTU
2Channel ABlock1 Bit1.3 enableCW
2Automatic modeControl value heating1 Byte5.1 percentage (0..100%)CW
2Automatic modeControl value heating/cooling1 Byte5.1 percentage (0..100%)CW
3Channel AScene1 Byte17.1 scene numberCW
3Automatic modeControl value cooling1 Byte5.1 percentage (0..100%)CW
4Channel AState1 Bit1.11 stateCRT
4Automatic modeControl value failure1 Bit1.1 switchCRT
5Channel ALogic 11 Bit1.2 booleanCW
5Automatic modeHeating/cooling switch over1 Bit1.100 heating/coolingCRWTU
5Automatic modeHeating/cooling switch over1 Bit1.100 heating/coolingCRT
6Channel ALogic 21 Bit1.2 booleanCW
6Automatic modeSwitch heating valve1 Bit1.1 switchCT
6Automatic modeSwitch heating valve1 Bit1.1 switchCRT
6Automatic modeSwitch heating/cooling valve1 Bit1.1 switchCRT
7Automatic modeSwitch cooling valve1 Bit1.1 switchCRT
8Automatic modeManual set point offset (1=+/0=-)1 Bit1.7 stepCW
9Channel BSwitch On/Off1 Bit1.1 switchCW
9Direct modeStep 01 Bit1.1 switchCW
9Direct modeBit 01 Bit1.1 switchCW
9Direct modeUp/Down1 Bit1.7 stepCW
10Channel BStaircase1 Bit1.1 switchCW
10Direct modeStep 11 Bit1.1 switchCW
10Direct modeBit 11 Bit1.1 switchCW
11Channel BBlock1 Bit1.3 enableCW
11Direct modeStep 21 Bit1.1 switchCW
12Channel BScene1 Byte17.1 scene numberCW
12Direct modeStep 31 Bit1.1 switchCW
13Channel BState1 Bit1.11 stateCRT
13Status input (Cascading)External heating request1 Bit1.1 switchCW
14Channel BLogic 11 Bit1.2 booleanCW
14Status outputExternal heating request1 Bit1.1 switchCRT
15Channel BLogic 21 Bit1.2 booleanCW
15Status input (Cascading)External cooling request1 Bit1.1 switchCW
16Status outputExternal cooling request1 Bit1.1 switchCRT
17Status input (Cascading)Maximum control value for heating1 Byte5.1 percentage (0..100%)CW
18Channel CSwitch On/Off1 Bit1.1 switchCW
18Status outputMaximum control value for heating1 Byte5.1 percentage (0..100%)CRT
19Channel CStaircase1 Bit1.1 switchCW
19Status input (Cascading)Maximum control value for cooling1 Byte5.1 percentage (0..100%)CW
20Channel CBlock1 Bit1.3 enableCW
20Status outputMaximum control value for cooling1 Byte5.1 percentage (0..100%)CRT
21Status input (Cascading)Maximum fan level heating1 Byte5.5 ratio (0..255)CW
21Channel CScene1 Byte17.1 scene numberCW
22Status outputMaximum fan level heating1 Byte5.5 ratio (0..255)CRT
22Channel CState1 Bit1.11 stateCRT
23Status input (Cascading)Maximum fan level cooling1 Byte5.5 ratio (0..255)CW
23Channel CLogic 11 Bit1.2 booleanCW
24Status outputMaximum fan level cooling1 Byte5.5 ratio (0..255)CRT
24Channel CLogic 21 Bit1.2 booleanCW
25Block object 1Block1 Bit1.3 enableCW
26Block object 2Block1 Bit1.3 enableCW
27Automatic modeTemperature value2 Bytes9.1 temperature (°C)CW
28Automatic modeSetpoint temperature2 Bytes9.1 temperature (°C)CW
29Automatic modeSetpoint offset2 Bytes9.2 temperature difference (K)CW
30Automatic modeCurrent setpoint temperature2 Bytes9.1 temperature (°C)CRT
31Additional functionsOutdoor temperature2 Bytes9.1 temperature (°C)CW
32Switching Summer/Winter0 = Winter / 1 = Summer1 Bit1.1 switchCRWT
33Summer night coolingEnable1 Bit1.1 switchCW
34Summer night coolingSwitch output1 Bit1.1 switchCRT
35Sun heatingEnable1 Bit1.1 switchCW
36Sun heatingSwitch output1 Bit1.1 switchCRT
37Automatic dehumidificationEnable1 Bit1.1 switchCW
38Automatic dehumidificationIndoor atmospheric humidity2 Bytes9.7 humidity (%)CW
39Automatic dehumidificationOutdoor atmospheric humidity2 Bytes9.7 humidity (%)CW
40Automatic dehumidificationSwitch output1 Bit1.1 switchCRT
41Additional functionsCollector output1 Bit1.1 switchCRT
42Dummy01 Bit
43Dummy11 Bit
44Dummy21 Bit
45Central functionSwitch On/Off1 Bit1.1 switchCW
46OperatingSend Status1 Bit1.11 stateCRT
47Day/NightSwitching1 Bit1.1 switchCW
47Day/NightSwitching1 Bit1.1 switchCRWT
48Dummy31 Bit
49Dummy41 Bit
Parameters (131)
ParameterTypeDefault
On delay [s]unsignedInt 0…300000
Off delay [s]unsignedInt 0…300000
Time for staircase [s]unsignedInt 0…300000
Prewarning time in [s]unsignedInt 0…300000
Warning time [s]unsignedInt 0…300001
Manual switching offlistnot active
Modelistnormally open
invertieren des Lock Objekteslistnot inverted
Behaviour when unlockedlistno change
Behaviour when lockedlistno change
Scene number Hlist8
Scene number Glist7
Scene number Flist6
Scene number Elist5
Scene number Dlist4
Scene number Clist3
Scene number Blist2
Scene number Alist1
Scene HlistOff
Scene GlistOff
Scene FlistOff
Scene ElistOff
Scene DlistOff
Scene ClistOff
Scene BlistOff
Scene AlistOff
Logic operationslistOR
logic OperationslistOR
active Logic Inputslistnot active
Save scenelistdisabled
Send cyclic of current value [s]unsignedInt 0…300000
Send status at bus power up afterlist1 s
Verhalten bei Busspannungsausfalllistno change
Central functionlistnot active
Function Channel AlistSwitch
Function Channel BlistSwitch
Extend staircase timelistnot active
Behaviour at bus power uplistno change
Logical functionslistnot active
Scenelistnot active
Prewarninglistnot active
Function Channel ClistSwitch
Startup timeoutunsignedInt 0…1205
cyclic telegram "Operating"listnot used
Day/Night objectlistno use
Polarity of Day/Night objectlistDay = 1 / Night = 0
ModelistFanCoil
Betriebsart Lüfterlisttoggle switch
Type of FanCoil systemlist2-Rohr, only heating and cooling
Send cyclic Switch heating valveunsignedInt 0…36000
Send cyclicunsignedInt 0…36000
Delay between step switchingunsignedInt 50…5000200
Type of step switchinglistswitch successive
Minimum holding time of each stepunsignedInt 0…10005
Maximum step at nightlistStep 3
Switch-on behaviorlistdirect start
Minimum holding time of start-up levelunsignedInt 0…10000
Off delay of the fanunsignedInt 0…10000
Sommer/Winter ObjektlistSummer = 1 / Winter = 0
Block object 1listnot active
Action at activation of blocking 1listswitch to step 2
Action at deactivation of blocking 1listrestore previous step (memory function)
Block object 2listnot active
Action at activation of blocking 2listswitch to step 2
Action at deactivation of blocking 2listrestore previous step (memory function)
Additional Fanlistnot active
Automatic modelistactive
Deirect modelistnot active
Status objectlistactive
Zusätzliche Funktionenlistnot active
Cyclic time for additional fanunsignedInt 0…15000
Duration for additional fanunsignedInt 0…10000
Step additional fanlistStep 2
Manual additional fanlistactive
Duration for manual additional fanunsignedInt 0…180020
Step manual additional fanlistStep 3
Automatic modelistcontrol value
Release time to automatic modeunsignedInt 0…14400
Dead time at switching Heating/CoolingunsignedInt 0…100060
Monitoring time of control valueunsignedInt 0…3600
Ventilating fan step with control value failurelistStep 1
Threshold for fan step 1list5%
Threshold for fan step 2list50%
Threshold for fan step 3list80%
Threshold for fan step 1list0,5 K
Threshold for fan step 2list1,5 K
Threshold for fan step 3list3,0 K
Hysteresislist0,2 K
Hysteresislist2%
Umschalten zwischen Heizen und Kühlenlistmanually over object, 1 control value
Switch over between heating and coolinglistautomatically by control value
Setpoint temperaturelist21 °C
Setpoint offset over 2Byte objectlistnot active
Maximum setpoint offsetlist1,0 K
Setpoint offset over 1Bit objectlistnot active
Step rangelist0,5 K
Switch over between heating and coolinglistover temperature and over object
Dead zone between Heating and Coolinglist2,0 K
Setting of the input mode for direct operationliststep switch
Step for statuslistuse actual step
Status fan at heating modelistactive
Send conditionlistat changes
Time for cyclic sendingunsignedInt 0…3600300
Status fan at heating mode active cascadablelistnot active
Status maximum control valuelistnot active
Send conditionlistat changes (<2%)
Status of maximum control value cascadable at heating modelistnot active
Status maximum fanlistnot active
Status of maximum fan step cascadable at heating modelistnot active
Status fan at cooling modelistactive
Status fan at cooling mode active cascadablelistnot active
Status of maximum control valuelistnot active
Status of maximum control value cascadable at cooling modelistnot active
Status of maximum fan steplistnot active
Status of maximum fan step cascadable at cooling modelistnot active
Summer night coolinglistnot active
Type of activationlistactivated over switch object
Function active if indoor temperature >list21 °C
Minimal difference between outdoor and indoor temperaturelist2,0 K
Function active (0=always active) if outdoor temperature >list14 °C
Ventilator levellistswitch does not affect ventilation, only communication object
Sun heatinglistnot active
Type of activationlistactivated via switch object
Function active if indoor temperature <list21 °C
Automatic dehumidificationlistnot active
Function active if indoor absolute humidity >unsignedInt 80…250100
Minimum difference between outdoor and indoor humiditylist10%
Undercooling protectionlist18 °C
Overheating protectionlist23 °C
Collective object for all additional functionslistnot active
Behavior after bus power resetlistautomatic active

Version history

ApplicationApp noFingerprintFirst seenSizeFile
Switch, Staircase 3fold, FanCoil 1.0 latest$001A7B3F2026-11-25102 KBDownload

About this file

This is the official ETS product database for the MDT technologies GmbH AKK-03UP.01 Switch Actuator 3fold, FanCoil (AKK-03UP.01), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.