duct sensor KTF99

Lingg & Janke · Order number KTF99 · temperature sensors › DigiTemp series

Download .knxprod T adjust measure switch control B002-10 1.0 · 67 KB

Product

ManufacturerLingg & Janke
Product nameduct sensor
Order numberKTF99
HardwareKTF99
MediumTwisted Pair
Bus current (mA)5
Rail mountedNo
RegistrationCertified
Languagesen-US, de-DE
Catalog entryM-00E1_H-110003-1_HP-B002-10-36FD_CI-KTF99-1
Fingerprint36FD
SHA-256546bb1fa5971fa5ee3a35fceb7877109ec8cac8969a20d377204753ef07f8224
First seen2026-11-25
Markets69 markets

Application program: T adjust measure switch control B002-10 1.0

Application number$B002
Version1.0
Mask versionMV-0020 (2.0)
KNX Data SecureNo
Parameters40
Group objects13
Group objects (13)
NoNameFunctionSizeDPTFlags
0output temperaturetemperature2 Bytes9.1 temperature (°C)CRT
1output sensor statusOK-status1 Bit1.1 switchCRT
2output at upper limit Aupper threshold A1 Bit1.1 switchCRT
3output at lower limit Alower threshold A1 Bit1.1 switchCRT
4output at upper limit Bupper threshold B1 Bit1.1 switchCRT
5output at lower limit Blower threshold B1 Bit1.1 switchCRT
6output heating valveheating valve1 Byte5.1 percentage (0..100%)CRT
7output heating oncontroller in heating mode1 Bit1.2 booleanCRT
8output cooling valvecooling valve1 Byte5.1 percentage (0..100%)CRT
9output cooling oncontroller in cooling mode1 Bit1.2 booleanCRT
10input inhibit functionsinhibit functions1 Bit1.1 switchCRWT
11input upper limit Aset upper threshold A2 Bytes9.1 temperature (°C)CRWT
12input lower limit A / setpointset lower thresh. A / setpoint2 Bytes9.1 temperature (°C)CRWT
Parameters (29)
ParameterTypeDefault
temperaturelistYES
sensor statuslistNO
limits A / two-position controller AlistNO
limits B / two-position controller BlistNO
heating / cooling controllerlistNO
temperature offset (-20..20)signedInt -20…200
default upper limit A after bus-power recoverysignedInt -55…12526
default lower limit A / setpoint after bus-power recoverysignedInt -55…12522
timebaselist2.1 sec
factor [1..255]unsignedInt 1…25530
inhibit temperaturelistNO
send cycliclistYES
inhibit sensor statuslistNO
send cycliclistNO
inhibit limits A / two-position controller AlistNO
action at upper limit Alist>= ON / < OFF
action at lower limit Alist>= OFF / < ON
upper limit A is set at "bus-power recovery"listremark
lower limit A is set at "bus-power recovery"listremark
inhibit limits B / two-position controller BlistNO
action at upper limit Blist>= ON / < OFF
action at lower limit Blist>= OFF / < ON
fixed value of upper limit BsignedInt -55…12530
fixed value of lower limit BsignedInt -55…12510
inhibit controllerlistNO
integration time is "cyclic sending time"listYES
setpoint is set at "bus-power recovery"listremark
activate heating controllerlistYES
activate cooling controllerlistNO

Version history

ApplicationApp noFingerprintFirst seenSizeFile
T adjust measure switch control B002-10 1.0 latest$B00236FD2026-11-2567 KBDownload

About this file

This is the official ETS product database for the Lingg & Janke duct sensor (KTF99), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.