L&J secure switching actuator 3fold A3FX-SEC
Lingg & Janke · Order number A3FX-SEC · binary output › L&J secure series
Download .knxprod SEC 3x switching, time, scene, announce, inh. 2026-30 3.0 · 132 KB
Product
| Manufacturer | Lingg & Janke |
|---|---|
| Product name | L&J secure switching actuator 3fold |
| Order number | A3FX-SEC |
| Product text | L&J secure switching actuator 3f |
| Hardware | A3FX-SEC |
| Medium | Twisted Pair |
| Bus current (mA) | 5 |
| Rail mounted | Yes |
| Width (mm) | 54 |
| Registration | Certified · 2021-03-11 |
| Languages | en-US, de-DE |
| Catalog entry | M-00E1_H-2016.2D10-1_HP-2026-30-5AB5_CI-A3FX.2DSEC-1 |
| Fingerprint | 5AB5 |
| SHA-256 | 25a9e2bbbaddee7ada0357e3e704745d20fa8e96ac55fe081e0bad9bc63f98a4 |
| First seen | 2026-11-25 |
| Markets | 69 markets |
Application program: SEC 3x switching, time, scene, announce, inh. 2026-30 3.0
| Application number | $2026 |
|---|---|
| Version | 3.0 |
| Mask version | MV-0021 (2.1) |
| KNX Data Secure | Yes |
| Minimum ETS version | 5.0 |
| Parameters | 330 |
| Group objects | 48 |
Group objects (48)
| No | Name | Function | Size | DPT | Flags |
|---|---|---|---|---|---|
| 0 | input A, CH1 switching | channel A, CH1 object 1 | 1 Bit | 1.1 switch | CW |
| 0 | input A1, CH1 OR | channel A, CH1 object 1 | 1 Bit | 1.1 switch | CW |
| 0 | input A1, CH1 EXOR | channel A, CH1 object 1 | 1 Bit | 1.1 switch | CW |
| 0 | input A1, CH1 AND | channel A, CH1 object 1 | 1 Bit | 1.1 switch | CW |
| 1 | input A2, CH1 OR | channel A, CH1 object 2 | 1 Bit | 1.1 switch | CW |
| 1 | input A2, CH1 EXOR | channel A, CH1 object 2 | 1 Bit | 1.1 switch | CW |
| 1 | input A2, CH1 AND | channel A, CH1 object 2 | 1 Bit | 1.1 switch | CW |
| 2 | output A, CH1 status | channel A, CH1 object 3 | 1 Bit | 1.1 switch | CT |
| 2 | output A, CH1 status INV | channel A, CH1 object 3 | 1 Bit | 1.1 switch | CT |
| 3 | input A, CH1 scenes | channel A, CH1 object 4 | 1 Byte | 18.1 scene control | CW |
| 4 | input A, CH1 announce | channel A, CH1 object 5 | 1 Bit | 1.1 switch | CW |
| 5 | input A, CH1 inhibit | channel A, CH1 object 6 | 1 Bit | 1.1 switch | CW |
| 6 | input A, CH1 reset hour meter | channel A, CH1 object 7 | 1 Bit | 1.15 reset | CW |
| 7 | output A, CH1 hour meter (h) | channel A, CH1 object 8 | 2 Bytes | 7.7 time (h) | CT |
| 7 | output A, CH1 hour meter (s) | channel A, CH1 object 8 | 4 Bytes | 13.100 time lag (s) | CT |
| 8 | output A, CH1 limit reached | channel A, CH1 object 9 | 1 Bit | 1.2 boolean | CT |
| 9 | input B1, CH2 OR | channel B, CH2 object 1 | 1 Bit | 1.1 switch | CW |
| 9 | input B1, CH2 EXOR | channel B, CH2 object 1 | 1 Bit | 1.1 switch | CW |
| 9 | input B1, CH2 AND | channel B, CH2 object 1 | 1 Bit | 1.1 switch | CW |
| 9 | input B, CH2 switching | channel B, CH2 object 1 | 1 Bit | 1.1 switch | CW |
| 10 | input B2, CH2 EXOR | channel B, CH2 object 2 | 1 Bit | 1.1 switch | CW |
| 10 | input B2, CH2 AND | channel B, CH2 object 2 | 1 Bit | 1.1 switch | CW |
| 10 | input B2, CH2 OR | channel B, CH2 object 2 | 1 Bit | 1.1 switch | CW |
| 11 | output B, CH2 status | channel B, CH2 object 3 | 1 Bit | 1.1 switch | CT |
| 11 | output B, CH2 status INV | channel B, CH2 object 3 | 1 Bit | 1.1 switch | CT |
| 12 | input B, CH2 scenes | channel B, CH2 object 4 | 1 Byte | 18.1 scene control | CW |
| 13 | input B, CH2 announce | channel B, CH2 object 5 | 1 Bit | 1.1 switch | CW |
| 14 | input B, CH2 inhibit | channel B, CH2 object 6 | 1 Bit | 1.1 switch | CW |
| 15 | input B, CH2 reset hour meter | channel B, CH2 object 7 | 1 Bit | 1.15 reset | CW |
| 16 | output B, CH2 hour meter (h) | channel B, CH2 object 8 | 2 Bytes | 7.7 time (h) | CT |
| 16 | output B, CH2 hour meter (s) | channel B, CH2 object 8 | 4 Bytes | 13.100 time lag (s) | CT |
| 17 | output B, CH2 limit reached | channel B, CH2 object 9 | 1 Bit | 1.2 boolean | CT |
| 18 | input C1, CH3 OR | channel C, CH3 object 1 | 1 Bit | 1.1 switch | CW |
| 18 | input C1, CH3 EXOR | channel C, CH3 object 1 | 1 Bit | 1.1 switch | CW |
| 18 | input C1, CH3 AND | channel C, CH3 object 1 | 1 Bit | 1.1 switch | CW |
| 18 | input C, CH3 switching | channel C, CH3 object 1 | 1 Bit | 1.1 switch | CW |
| 19 | input C2, CH3 AND | channel C, CH3 object 2 | 1 Bit | 1.1 switch | CW |
| 19 | input C2, CH3 OR | channel C, CH3 object 2 | 1 Bit | 1.1 switch | CW |
| 19 | input C2, CH3 EXOR | channel C, CH3 object 2 | 1 Bit | 1.1 switch | CW |
| 20 | output C, CH3 status | channel C, CH3 object 3 | 1 Bit | 1.1 switch | CT |
| 20 | output C, CH3 status INV | channel C, CH3 object 3 | 1 Bit | 1.1 switch | CT |
| 21 | input C, CH3 scenes | channel C, CH3 object 4 | 1 Byte | 18.1 scene control | CW |
| 22 | input C, CH3 announce | channel C, CH3 object 5 | 1 Bit | 1.1 switch | CW |
| 23 | input C, CH3 inhibit | channel C, CH3 object 6 | 1 Bit | 1.1 switch | CW |
| 24 | input C, CH3 reset hour meter | channel C, CH3 object 7 | 1 Bit | 1.15 reset | CW |
| 25 | output C, CH3 hour meter (h) | channel C, CH3 object 8 | 2 Bytes | 7.7 time (h) | CT |
| 25 | output C, CH3 hour meter (s) | channel C, CH3 object 8 | 4 Bytes | 13.100 time lag (s) | CT |
| 26 | output C, CH3 limit reached | channel C, CH3 object 9 | 1 Bit | 1.2 boolean | CT |
Parameters (75)
| Parameter | Type | Default |
|---|---|---|
| usage | list | enabled |
| at buspower recovery set switching object to | list | do not initialize |
| relay contact is | list | NO (norm. open) |
| at buspower failure contact is | list | no change |
| timing functions | list | no |
| logic combination | list | no |
| status | list | no |
| scenes | list | no |
| announce function | list | no |
| inhibit function | list | no |
| hour meter | list | no |
| switch on delay | list | no |
| delay time (1..255 sec) | unsignedInt 1…255 | 5 |
| switch off delay | list | no |
| staircase function / blinking | list | no |
| on time (1..255 sec) | unsignedInt 1…255 | 3 |
| off time (1..255 sec) | unsignedInt 1…255 | 3 |
| staircase on time (1..64800 sec) | unsignedInt 1…64800 | 180 |
| retrigger staircase time (only, if on/off delay disabled) | list | yes |
| staircase prewarning | list | no |
| prewarning off time (1..30 *100 ms) | unsignedInt 1…30 | 5 |
| prewarning on time (1..255 sec) | unsignedInt 1…255 | 3 |
| number of prewarnings (1..7) | unsignedInt 1…7 | 3 |
| logic combination | list | none |
| at buspower recovery set logic object to | list | "1" |
| status is transmitted | list | at value change |
| status send delay time (0..120 *100 ms) | unsignedInt 0…120 | 1 |
| scene 1 | list | no action |
| scene 2 | list | no action |
| scene 3 | list | no action |
| scene 4 | list | no action |
| scene 5 | list | no action |
| scene 6 | list | no action |
| scene 7 | list | no action |
| scene 8 | list | no action |
| scene 9 | list | no action |
| scene 10 | list | no action |
| scene 11 | list | no action |
| scene 12 | list | no action |
| scene 13 | list | no action |
| scene 14 | list | no action |
| scene 15 | list | no action |
| scene 16 | list | no action |
| scene 17 | list | no action |
| scene 18 | list | no action |
| scene 19 | list | no action |
| scene 20 | list | no action |
| scene 21 | list | no action |
| scene 22 | list | no action |
| scene 23 | list | no action |
| scene 24 | list | no action |
| scene 25 | list | no action |
| scene 26 | list | no action |
| scene 27 | list | no action |
| scene 28 | list | no action |
| scene 29 | list | no action |
| scene 30 | list | no action |
| scene 31 | list | no action |
| scene 32 | list | no action |
| enable scene saving | list | no |
| announce with | list | "1" |
| at bus voltage recovery set announce object to | list | "0" |
| action when announce starts | list | no action |
| on time (1..15 sec) | unsignedInt 1…15 | 3 |
| off time (1..15 sec) | unsignedInt 1…15 | 3 |
| action when announce ends | list | no action |
| inhibit with | list | "1" |
| at bus voltage recovery set inhibit object to | list | "0" |
| action when inhibit starts | list | no action |
| action when inhibit ends | list | no action |
| hour meter values are presented in | list | DPT 7.007 hours (16bit unsigned int EIS10) |
| hour meter reading is transmitted | list | cyclically |
| cycle time | list | 5 min |
| hour meter limit monitoring | list | no |
| limit (1..65000 h) | unsignedInt 1…65535 | 1000 |
Version history
| Application | App no | Fingerprint | First seen | Size | File |
|---|---|---|---|---|---|
| SEC 3x switching, time, scene, announce, inh. 2026-30 3.0 latest | $2026 | 5AB5 | 2026-11-25 | 132 KB | Download |
About this file
This is the official ETS product database for the Lingg & Janke L&J secure switching actuator 3fold (A3FX-SEC), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.
More from Lingg & Janke
- AH3F16H-SEC switching actuator 3fold 79236-SEC
- AH5F16H-SEC switching actuator 5fold 79237-SEC
- AH9F16H-SEC switching actuator 9fold 79238-SEC
- switching actuator 2fold A2FX-E-Q
- L&J secure switching actuator 2fold A2FX-SEC
- switching actor 2x6fold 16A hand A2X6F16H
- switching actuator 2x6fold A2X6F16H-2
- switching actuator 3fold A3FX-E-Q
- switching actuator 4fold A4FX-E-Q
- L&J secure switching actuator 4fold A4FX-SEC
- switching actuator 5fold A5FX-E-Q
- L&J secure switching actuator 5fold A5FX-SEC