KNX Database

ON-OFF DIN CONTROLLER 4 outputs 16A 002664

LEGRAND Appareillage électrique · Order number 002664 · output › on/off

Status, logic operation and time function

Download .knxprod 20 A4 Binary A68 0.1 · 73 KB

Product

ManufacturerLEGRAND Appareillage électrique
Product nameON-OFF DIN CONTROLLER 4 outputs 16A
Order number002664
Hardware#Lastschalter N 510/03, N510/04
MediumTwisted Pair
Bus current (mA)10
Rail mountedYes
RegistrationCertified · 2013-04-29
Languagesen-US, it-IT, de-DE
Catalog entryM-000B_H-hp.5F00129-1-O0001_HP-0A68-01-6581-O0001_CI-002664-18
Fingerprint6581
SHA-2563d8efc43322d8d23534679acef522c0c5b12c7bd02895ff7caff46f52e9e73d3
First seen2026-11-25
MarketsChina, France, India, Italy, United Kingdom

Application program: 20 A4 Binary A68 0.1

Application number$0A68
Version0.1
Mask versionMV-0020 (2.0)
KNX Data SecureNo
Parameters93
Group objects24
Group objects (24)
NoNameFunctionSizeDPTFlags
0Switch, Channel AOn / Off1 BitCW
1Switch, Channel BOn / Off1 BitCW
2Switch, Channel COn / Off1 BitCW
3Switch, Channel DOn / Off1 BitCW
4Status, Channel AOn / Off1 BitCRT
4Status, Channel AOn / Off1 BitCR
5Status, Channel BOn / Off1 BitCRT
5Status, Channel BOn / Off1 BitCR
6Status, Channel COn / Off1 BitCRT
6Status, Channel COn / Off1 BitCR
7Status, Channel DOn / Off1 BitCRT
7Status, Channel DOn / Off1 BitCR
8Logic operation, Channel AOR function1 BitCRW
9Logic operation, Channel BOR function1 BitCRW
10Logic operation, Channel COR function1 BitCRW
11Logic operation, Channel DOR function1 BitCRW
12Logic operation, Channel AAND function1 BitCRW
13Logic operation, Channel BAND function1 BitCRW
14Logic operation, Channel CAND function1 BitCRW
15Logic operation, Channel DAND function1 BitCRW
16Positive drive, Channel AOn / Off2 BitCRW
17Positive drive, Channel BOn / Off2 BitCRW
18Positive drive, Channel COn / Off2 BitCRW
19Positive drive, Channel DOn / Off2 BitCRW
Parameters (27)
ParameterTypeDefault
Device, OrdernumberlistN510/03 (5WG1 510-1AB03)
Switch relay of a channellistafter each telegram information
Relay controllist§Dummy
Channel Alistenabled
Operating modelistNormal mode
Positive drive (priority 1)listno positive drive
Logic operation AND (priority 2)listno logic operation
OR function (Prio. 3)listno logic operation
Relay modelistnormally open contact
On / Off delaylistdisabled
Factor for On delay (0-127)unsignedInt 0…1270
Base for On delaylistTime base 130 ms
Factor for Off delay (0-127)unsignedInt 0…1270
Factor for overshoot time (5-127)unsignedInt 5…1275
Base for Off delaylistTime base 130 ms
Base for overshoot timelistTime base 130 ms
Initialization of object valueslistadjustable
Initial value of switch objectlistlogic 0 (Off)
Initial value of positive drive objectlistPositive drive Off
Initial value of AND objectlistlogic 0 (Off)
Initial value of OR objectlistlogic 0 (Off)
Bus voltage failurelistBus voltage failure
Behaviour on bus voltage failurelistrelay drops down
Status transmittinglistif object value changes/at bus recovery
Channel Blistenabled
Channel Clistenabled
Channel Dlistenabled

Version history

ApplicationApp noFingerprintFirst seenSizeFile
20 A4 Binary A68 0.2 latest$0A68A9FE2026-11-2574 KBDownload
20 A4 Binary A68 0.1$0A6865812026-11-2573 KBDownload

About this file

This is the official ETS product database for the LEGRAND Appareillage électrique ON-OFF DIN CONTROLLER 4 outputs 16A (002664), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.

More from LEGRAND Appareillage électrique

All LEGRAND Appareillage électrique products