ERL1604-KNX/G 31001521
LAZZEN · Order number 31001521 · Actuator › Switch
Download .knxprod Switch Actuator with Secure, 4-Fold/3.0 3.0 · 176 KB
Product
| Manufacturer | LAZZEN |
|---|---|
| Product name | ERL1604-KNX/G |
| Order number | 31001521 |
| Product text | Switch Actuator, 4-Fold(16A) |
| Hardware | ERL1604-KNX/G |
| Medium | Twisted Pair |
| Bus current (mA) | 6.5 |
| Rail mounted | Yes |
| Width (mm) | 72 |
| Registration | Certified · 2023-12-14 |
| Languages | en-US, de-DE, zh-CN |
| Catalog entry | M-02BC_H-AR22ED-1-O0085_HP-0085-30-5E4E-O0085_CI-31001521-1 |
| Fingerprint | 5E4E |
| SHA-256 | df9466d6dd5f839b374cc63ed03ff1cca8377333361d7465afae598b4aeca6be |
| First seen | 2026-11-25 |
| Markets | China |
Application program: Switch Actuator with Secure, 4-Fold/3.0 3.0
| Application number | $0085 |
|---|---|
| Version | 3.0 |
| Mask version | MV-07B0 (System B) |
| KNX Data Secure | Yes |
| Minimum ETS version | 5.0 |
| Parameters | 550 |
| Group objects | 154 |
Group objects (154)
| No | Name | Function | Size | DPT | Flags |
|---|---|---|---|---|---|
| 1 | General | In operation | 1 Bit | 1.1 switch | CRT |
| 2 | General | Safety priority 1 | 1 Bit | 1.3 enable | CWU |
| 3 | General | Safety priority 2 | 1 Bit | 1.3 enable | CWU |
| 4 | Output A-{{0:...}} | Switch status | 1 Bit | 1.1 switch | CRT |
| 5 | Output A-{{0:...}} | Switch | 1 Bit | 1.1 switch | CW |
| 5 | Output A-{{0:...}} | On-Off | 1 Bit | 1.1 switch | CW |
| 6 | Output A-{{0:...}} | Status (continuous),1 bit | 1 Bit | 1.1 switch | CRT |
| 6 | Output A-{{0:...}} | Switch out with delay | 1 Bit | 1.1 switch | CW |
| 6 | Output A-{{0:...}} | Switch out with flashing | 1 Bit | 1.1 switch | CW |
| 6 | Output A-{{0:...}} | Output of staircase lighting | 1 Bit | 1.1 switch | CW |
| 7 | Output A-{{0:...}} | Switch time function | 1 Bit | 1.3 enable | CW |
| 8 | Output A-{{0:...}} | Warning of staircase | 1 Bit | 1.5 alarm | CT |
| 8 | Output A-{{0:...}} | Report fault | 1 Bit | 1.5 alarm | CRT |
| 9 | Output A-{{0:...}} | Duration of staircase | 2 Bytes | 7.5 time (s) | CRW |
| 10 | Output A-{{0:...}} | Recall preset | 1 Bit | 1.22 scene | CW |
| 11 | Output A-{{0:...}} | Store preset | 1 Bit | 1.22 scene | CW |
| 11 | Output A-{{0:...}} | Trigger switch regularly | 1 Bit | 1.3 enable | CW |
| 12 | Output A-{{0:...}} | Input 1 of logic | 1 Bit | 1.2 boolean | CW |
| 13 | Output A-{{0:...}} | Input 2 of logic | 1 Bit | 1.2 boolean | CW |
| 14 | Output A-{{0:...}} | Status (continuous),1 byte | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 14 | Output A-{{0:...}} | Scene | 1 Byte | 18.1 scene control | CW |
| 15 | Output A-{{0:...}} | Continuous control | 1 Byte | 5.1 percentage (0..100%) | CW |
| 15 | Output A-{{0:...}} | Change threshold 1 | 1 Byte | 5.10 counter pulses (0..255) | CW |
| 16 | Output A-{{0:...}} | Threshold input | 1 Byte | 5.10 counter pulses (0..255) | CW |
| 17 | Output A-{{0:...}} | Forced operation | 1 Bit | 1.1 switch | CW |
| 17 | Output A-{{0:...}} | Forced operation | 2 Bit | 2.1 switch control | CW |
| 17 | Output A-{{0:...}} | Forced operation | 1 Bit | 1.3 enable | CW |
| 18 | Output B-{{0:...}} | Switch status | 1 Bit | 1.1 switch | CRT |
| 19 | Output B-{{0:...}} | Switch | 1 Bit | 1.1 switch | CW |
| 19 | Output B-{{0:...}} | On-Off | 1 Bit | 1.1 switch | CW |
| 20 | Output B-{{0:...}} | Switch out with delay | 1 Bit | 1.1 switch | CW |
| 20 | Output B-{{0:...}} | Switch out with flashing | 1 Bit | 1.1 switch | CW |
| 20 | Output B-{{0:...}} | Output of staircase lighting | 1 Bit | 1.1 switch | CW |
| 20 | Output B-{{0:...}} | Status (continuous),1 bit | 1 Bit | 1.1 switch | CRT |
| 21 | Output B-{{0:...}} | Switch time function | 1 Bit | 1.3 enable | CW |
| 22 | Output B-{{0:...}} | Warning of staircase | 1 Bit | 1.5 alarm | CT |
| 22 | Output B-{{0:...}} | Report fault | 1 Bit | 1.5 alarm | CRT |
| 23 | Output B-{{0:...}} | Duration of staircase | 2 Bytes | 7.5 time (s) | CRW |
| 24 | Output B-{{0:...}} | Recall preset | 1 Bit | 1.22 scene | CW |
| 25 | Output B-{{0:...}} | Store preset | 1 Bit | 1.22 scene | CW |
| 25 | Output B-{{0:...}} | Trigger switch regularly | 1 Bit | 1.3 enable | CW |
| 26 | Output B-{{0:...}} | Input 1 of logic | 1 Bit | 1.2 boolean | CW |
| 27 | Output B-{{0:...}} | Input 2 of logic | 1 Bit | 1.2 boolean | CW |
| 28 | Output B-{{0:...}} | Scene | 1 Byte | 18.1 scene control | CW |
| 28 | Output B-{{0:...}} | Status (continuous),1 byte | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 29 | Output B-{{0:...}} | Change threshold 1 | 1 Byte | 5.10 counter pulses (0..255) | CW |
| 29 | Output B-{{0:...}} | Continuous control | 1 Byte | 5.1 percentage (0..100%) | CW |
| 30 | Output B-{{0:...}} | Threshold input | 1 Byte | 5.10 counter pulses (0..255) | CW |
| 31 | Output B-{{0:...}} | Forced operation | 1 Bit | 1.1 switch | CW |
| 31 | Output B-{{0:...}} | Forced operation | 2 Bit | 2.1 switch control | CW |
| 31 | Output B-{{0:...}} | Forced operation | 1 Bit | 1.3 enable | CW |
| 32 | Output C-{{0:...}} | Switch status | 1 Bit | 1.1 switch | CRT |
| 33 | Output C-{{0:...}} | Switch | 1 Bit | 1.1 switch | CW |
| 33 | Output C-{{0:...}} | On-Off | 1 Bit | 1.1 switch | CW |
| 34 | Output C-{{0:...}} | Switch out with delay | 1 Bit | 1.1 switch | CW |
| 34 | Output C-{{0:...}} | Switch out with flashing | 1 Bit | 1.1 switch | CW |
| 34 | Output C-{{0:...}} | Output of staircase lighting | 1 Bit | 1.1 switch | CW |
| 34 | Output C-{{0:...}} | Status (continuous),1 bit | 1 Bit | 1.1 switch | CRT |
| 35 | Output C-{{0:...}} | Switch time function | 1 Bit | 1.3 enable | CW |
| 36 | Output C-{{0:...}} | Warning of staircase | 1 Bit | 1.5 alarm | CT |
| 36 | Output C-{{0:...}} | Report fault | 1 Bit | 1.5 alarm | CRT |
| 37 | Output C-{{0:...}} | Duration of staircase | 2 Bytes | 7.5 time (s) | CRW |
| 38 | Output C-{{0:...}} | Recall preset | 1 Bit | 1.22 scene | CW |
| 39 | Output C-{{0:...}} | Store preset | 1 Bit | 1.22 scene | CW |
| 39 | Output C-{{0:...}} | Trigger switch regularly | 1 Bit | 1.3 enable | CW |
| 40 | Output C-{{0:...}} | Input 1 of logic | 1 Bit | 1.2 boolean | CW |
| 41 | Output C-{{0:...}} | Input 2 of logic | 1 Bit | 1.2 boolean | CW |
| 42 | Output C-{{0:...}} | Scene | 1 Byte | 18.1 scene control | CW |
| 42 | Output C-{{0:...}} | Status (continuous),1 byte | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 43 | Output C-{{0:...}} | Change threshold 1 | 1 Byte | 5.10 counter pulses (0..255) | CW |
| 43 | Output C-{{0:...}} | Continuous control | 1 Byte | 5.1 percentage (0..100%) | CW |
| 44 | Output C-{{0:...}} | Threshold input | 1 Byte | 5.10 counter pulses (0..255) | CW |
| 45 | Output C-{{0:...}} | Forced operation | 1 Bit | 1.1 switch | CW |
| 45 | Output C-{{0:...}} | Forced operation | 2 Bit | 2.1 switch control | CW |
| 45 | Output C-{{0:...}} | Forced operation | 1 Bit | 1.3 enable | CW |
| 46 | Output D-{{0:...}} | Switch status | 1 Bit | 1.1 switch | CRT |
| 47 | Output D-{{0:...}} | Switch | 1 Bit | 1.1 switch | CW |
| 47 | Output D-{{0:...}} | On-Off | 1 Bit | 1.1 switch | CW |
| 48 | Output D-{{0:...}} | Switch out with delay | 1 Bit | 1.1 switch | CW |
| 48 | Output D-{{0:...}} | Switch out with flashing | 1 Bit | 1.1 switch | CW |
| 48 | Output D-{{0:...}} | Output of staircase lighting | 1 Bit | 1.1 switch | CW |
| 48 | Output D-{{0:...}} | Status (continuous),1 bit | 1 Bit | 1.1 switch | CRT |
| 49 | Output D-{{0:...}} | Switch time function | 1 Bit | 1.3 enable | CW |
| 50 | Output D-{{0:...}} | Warning of staircase | 1 Bit | 1.5 alarm | CT |
| 50 | Output D-{{0:...}} | Report fault | 1 Bit | 1.5 alarm | CRT |
| 51 | Output D-{{0:...}} | Duration of staircase | 2 Bytes | 7.5 time (s) | CRW |
| 52 | Output D-{{0:...}} | Recall preset | 1 Bit | 1.22 scene | CW |
| 53 | Output D-{{0:...}} | Store preset | 1 Bit | 1.22 scene | CW |
| 53 | Output D-{{0:...}} | Trigger switch regularly | 1 Bit | 1.3 enable | CW |
| 54 | Output D-{{0:...}} | Input 1 of logic | 1 Bit | 1.2 boolean | CW |
| 55 | Output D-{{0:...}} | Input 2 of logic | 1 Bit | 1.2 boolean | CW |
| 56 | Output D-{{0:...}} | Scene | 1 Byte | 18.1 scene control | CW |
| 56 | Output D-{{0:...}} | Status (continuous),1 byte | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 57 | Output D-{{0:...}} | Change threshold 1 | 1 Byte | 5.10 counter pulses (0..255) | CW |
| 57 | Output D-{{0:...}} | Continuous control | 1 Byte | 5.1 percentage (0..100%) | CW |
| 58 | Output D-{{0:...}} | Threshold input | 1 Byte | 5.10 counter pulses (0..255) | CW |
| 59 | Output D-{{0:...}} | Forced operation | 1 Bit | 1.1 switch | CW |
| 59 | Output D-{{0:...}} | Forced operation | 2 Bit | 2.1 switch control | CW |
| 59 | Output D-{{0:...}} | Forced operation | 1 Bit | 1.3 enable | CW |
| 172 | Total current | Total active energy(Wh) | 4 Bytes | 13.10 active energy (Wh) | CRWT |
| 172 | Total current | Total active energy(kWh) | 4 Bytes | 13.13 active energy (kWh) | CRWT |
| 173 | Total current | Value of total current(A) | 4 Bytes | 14.19 electric current (A) | CRT |
| 173 | Total current | Value of total current(kW) | 2 Bytes | 9.24 power (kW) | CRT |
| 173 | Total current | Value of total current(mA) | 2 Bytes | 7.12 current (mA) | CRT |
| 173 | Total current | Value of total current(mA) | 2 Bytes | 9.21 current (mA) | CRT |
| 174 | Total current | Exceedance of total load | 1 Bit | 1.1 switch | CRWT |
| 175 | Output A-{{0:...}} | Current value(mA) | 2 Bytes | 7.12 current (mA) | CRT |
| 175 | Output A-{{0:...}} | Current value(mA) | 2 Bytes | 9.21 current (mA) | CRT |
| 175 | Output A-{{0:...}} | Current value(A) | 4 Bytes | 14.19 electric current (A) | CRT |
| 175 | Output A-{{0:...}} | Current value(kW) | 2 Bytes | 9.24 power (kW) | CRT |
| 176 | Output A-{{0:...}} | Exceedance of load | 1 Bit | 1.1 switch | CRT |
| 177 | Output A-{{0:...}} | Lower deviation of load | 1 Bit | 1.1 switch | CRT |
| 178 | Output A-{{0:...}} | Switch counter | 2 Bytes | 7.1 pulses | CRWT |
| 178 | Output A-{{0:...}} | Switch counter | 4 Bytes | 12.1 counter pulses (unsigned) | CRWT |
| 179 | Output A-{{0:...}} | Operation hours | 2 Bytes | 7.7 time (h) | CRWT |
| 179 | Output A-{{0:...}} | Operation hours | 4 Bytes | 13.100 time lag (s) | CRWT |
| 180 | Output A-{{0:...}} | Active energy(Wh) | 4 Bytes | 13.10 active energy (Wh) | CRWT |
| 180 | Output A-{{0:...}} | Active energy(kWh) | 4 Bytes | 13.13 active energy (kWh) | CRWT |
| 181 | Output B-{{0:...}} | Current value(mA) | 2 Bytes | 7.12 current (mA) | CRT |
| 181 | Output B-{{0:...}} | Current value(mA) | 2 Bytes | 9.21 current (mA) | CRT |
| 181 | Output B-{{0:...}} | Current value(A) | 4 Bytes | 14.19 electric current (A) | CRT |
| 181 | Output B-{{0:...}} | Current value(kW) | 2 Bytes | 9.24 power (kW) | CRT |
| 182 | Output B-{{0:...}} | Exceedance of load | 1 Bit | 1.1 switch | CRT |
| 183 | Output B-{{0:...}} | Lower deviation of load | 1 Bit | 1.1 switch | CRT |
| 184 | Output B-{{0:...}} | Switch counter | 2 Bytes | 7.1 pulses | CRWT |
| 184 | Output B-{{0:...}} | Switch counter | 4 Bytes | 12.1 counter pulses (unsigned) | CRWT |
| 185 | Output B-{{0:...}} | Operation hours | 2 Bytes | 7.7 time (h) | CRWT |
| 185 | Output B-{{0:...}} | Operation hours | 4 Bytes | 13.100 time lag (s) | CRWT |
| 186 | Output B-{{0:...}} | Active energy(Wh) | 4 Bytes | 13.10 active energy (Wh) | CRWT |
| 186 | Output B-{{0:...}} | Active energy(kWh) | 4 Bytes | 13.13 active energy (kWh) | CRWT |
| 187 | Output C-{{0:...}} | Current value(mA) | 2 Bytes | 7.12 current (mA) | CRT |
| 187 | Output C-{{0:...}} | Current value(mA) | 2 Bytes | 9.21 current (mA) | CRT |
| 187 | Output C-{{0:...}} | Current value(A) | 4 Bytes | 14.19 electric current (A) | CRT |
| 187 | Output C-{{0:...}} | Current value(kW) | 2 Bytes | 9.24 power (kW) | CRT |
| 188 | Output C-{{0:...}} | Exceedance of load | 1 Bit | 1.1 switch | CRT |
| 189 | Output C-{{0:...}} | Lower deviation of load | 1 Bit | 1.1 switch | CRT |
| 190 | Output C-{{0:...}} | Switch counter | 2 Bytes | 7.1 pulses | CRWT |
| 190 | Output C-{{0:...}} | Switch counter | 4 Bytes | 12.1 counter pulses (unsigned) | CRWT |
| 191 | Output C-{{0:...}} | Operation hours | 2 Bytes | 7.7 time (h) | CRWT |
| 191 | Output C-{{0:...}} | Operation hours | 4 Bytes | 13.100 time lag (s) | CRWT |
| 192 | Output C-{{0:...}} | Active energy(Wh) | 4 Bytes | 13.10 active energy (Wh) | CRWT |
| 192 | Output C-{{0:...}} | Active energy(kWh) | 4 Bytes | 13.13 active energy (kWh) | CRWT |
| 193 | Output D-{{0:...}} | Current value(mA) | 2 Bytes | 7.12 current (mA) | CRT |
| 193 | Output D-{{0:...}} | Current value(mA) | 2 Bytes | 9.21 current (mA) | CRT |
| 193 | Output D-{{0:...}} | Current value(A) | 4 Bytes | 14.19 electric current (A) | CRT |
| 193 | Output D-{{0:...}} | Current value(kW) | 2 Bytes | 9.24 power (kW) | CRT |
| 194 | Output D-{{0:...}} | Exceedance of load | 1 Bit | 1.1 switch | CRT |
| 195 | Output D-{{0:...}} | Lower deviation of load | 1 Bit | 1.1 switch | CRT |
| 196 | Output D-{{0:...}} | Switch counter | 2 Bytes | 7.1 pulses | CRWT |
| 196 | Output D-{{0:...}} | Switch counter | 4 Bytes | 12.1 counter pulses (unsigned) | CRWT |
| 197 | Output D-{{0:...}} | Operation hours | 2 Bytes | 7.7 time (h) | CRWT |
| 197 | Output D-{{0:...}} | Operation hours | 4 Bytes | 13.100 time lag (s) | CRWT |
| 198 | Output D-{{0:...}} | Active energy(Wh) | 4 Bytes | 13.10 active energy (Wh) | CRWT |
| 198 | Output D-{{0:...}} | Active energy(kWh) | 4 Bytes | 13.13 active energy (kWh) | CRWT |
Parameters (126)
| Parameter | Type | Default |
|---|---|---|
| Product type | list | 4-Fold Output |
| Relay drive type | list | Inverted(apply to Ver.2) |
| Operation delay after bus recovery [10…250] | unsignedInt 10…250 | 10 |
| Sending cycle of "In operation" telegram [1..240,0=inactive] | unsignedInt 0…240 | 0 |
| Total current | unsignedInt 0…1 | 0 |
| Enable safety priority function | unsignedInt 0…1 | 0 |
| Safety priority 1 | list | Inactive |
| Control period of safety priority 1 [1..240,0=inactive] | unsignedInt 0…240 | 0 |
| Safety priority 2 | list | Inactive |
| Control period of safety priority 2 [1..240,0=inactive] | unsignedInt 0…240 | 0 |
| Priority of safety operation | list | Priority of 2 is higher than that of 1 |
| Normal, object value of switch on/off | list | "1"=switch on; "0"=switch off |
| Object selection for the current measurement | list | Value in mA(DPT 7.012) |
| Factor for conversion into theoretical wattage kW: Current value x Factor | unsignedInt 100…250 | 230 |
| Send current value after changes value | list | Inactive |
| Cyclic send | list | Inactive |
| Monitoring exceedance of load | unsignedInt 0…1 | 0 |
| Factor for load monitoring [1..200] | unsignedInt 1…200 | 1 |
| Hysteresis [10..100] | unsignedInt 10…100 | 10 |
| Behavior at exceeding | list | Send no telegram |
| Behavior at not exceeding | list | Send no telegram |
| Send exceeding cyclical | list | Inactive |
| Total power meter function(Wh/kWh) | unsignedInt 0…1 | 0 |
| Object selection for power meter | list | Value in Wh(DPT 13.010) |
| Sending object value | list | Only request |
| Memory of all current detecting delete after download of application | unsignedInt 0…1 | 0 |
| Work mode of the channel is | list | Switch actuator |
| If bus recovery,output status is | list | Unchange |
| If bus failure,output status is | list | Unchange |
| Obj. value of "switch" after bus recovery | list | To write with "0" |
| Set the reply mode of switch status | list | Transmit after change |
| Object value of switch status | list | 0=contact open ; 1=contact close |
| Output status for the telegram "1" (telegram "0" is opposite of selection) | list | Contact close |
| Extension function | unsignedInt 0…1 | 0 |
| Valve type | list | Normal (de-energised closed) |
| If bus recovery, valve position is | list | 0%(OFF) |
| PWM cycle time for continuous control [1...240] | unsignedInt 1…240 | 3 |
| PWM cycle time for continuous control [0...59] | unsignedInt 0…59 | 0 |
| Control type | list | 1 bit ( on-off control ) |
| Reply the status of channel for continuous control | list | Nothing |
| Reply the status of contact state | list | Nothing |
| Function of "Time" | unsignedInt 0…1 | 0 |
| Function of "Preset" | unsignedInt 0…1 | 0 |
| Function of "Logic" | unsignedInt 0…1 | 0 |
| Function of "Scene" | unsignedInt 0…1 | 0 |
| Function of "Threshold" | unsignedInt 0…1 | 0 |
| Function of "Safety" | unsignedInt 0…1 | 0 |
| Function of "Forced" | unsignedInt 0…1 | 0 |
| Function of "Current" for switch | unsignedInt 0…1 | 0 |
| The mode of time function | list | Delay switch |
| Delay for switch on(contact close) --(0...240 minutes) | unsignedInt 0…240 | 0 |
| --(0...59 seconds) | unsignedInt 0…59 | 0 |
| Delay for switch off(contact open) --(0...240 minutes) | unsignedInt 0…240 | 0 |
| Duration of switch on(contact colose) --(0...240 minutes) | unsignedInt 0…240 | 0 |
| Duration of switch off(contact open) --(0...240 minutes) | unsignedInt 0…240 | 0 |
| Number of ON-impulses [1..255,0=no limited] | unsignedInt 0…255 | 0 |
| Output status after flashing | list | Unchange |
| Control mode of flashing | list | Start with "1" , Stop with "0" |
| Duration of staircase lighting --(0...1000 minutes) | unsignedInt 0…1000 | 2 |
| Control mode of staircase lighting | list | Start with "0/1" , can not be stop |
| During the lighting time, if receive the "Start" telegram | list | Restart duration of staircase lighting |
| Warning mode for ending of staircase lighting | list | Nothing |
| --The warning time for end of staircase lighting [0..59] | unsignedInt 0…59 | 0 |
| Modify the duration via object[0..60059s] | unsignedInt 0…1 | 0 |
| Output status of the telegram "0" | list | None |
| Output status of the telegram "1" | list | Contact open |
| Preset can be changed via bus | unsignedInt 0…1 | 0 |
| The input 0 (switch object) for logic | unsignedInt 0…1 | 0 |
| The input 1 of logic | unsignedInt 0…1 | 0 |
| Function type between input0 and input1 | list | AND |
| Invert result(if no,"1"=contact close,"0"=contact open;while yes is opposite) | unsignedInt 0…1 | 0 |
| Value of input 1 after bus recovery | list | "0" |
| The input 2 of logic | unsignedInt 0…1 | 0 |
| Function type between input2 and input0/1 | list | AND |
| Value of input 2 after bus recovery | list | "0" |
| 1> channel is assigned to (1..64,0=no allocation) | unsignedInt 0…64 | 0 |
| --Output status is | list | Contact open |
| 2> channel is assigned to (1..64,0=no allocation) | unsignedInt 0…64 | 0 |
| 3> channel is assigned to (1..64,0=no allocation) | unsignedInt 0…64 | 0 |
| 4> channel is assigned to (1..64,0=no allocation) | unsignedInt 0…64 | 0 |
| 5> channel is assigned to (1..64,0=no allocation) | unsignedInt 0…64 | 0 |
| 6> channel is assigned to (1..64,0=no allocation) | unsignedInt 0…64 | 0 |
| 7> channel is assigned to (1..64,0=no allocation) | unsignedInt 0…64 | 0 |
| 8> channel is assigned to (1..64,0=no allocation) | unsignedInt 0…64 | 0 |
| Threshold 1 value | unsignedInt 0…255 | 80 |
| Threshold 2 value | unsignedInt 0…255 | 200 |
| Threshold 1 can be changed via bus | unsignedInt 0…1 | 0 |
| Threshold behaviour | list | Without hysteresis |
| If falling below lower threshold, output status is | list | Unchange |
| If exceeding upper threshold, output status is | list | Unchange |
| If between lower and upper threshold, output status is | list | Unchange |
| Setting of safety | list | On parameter-window "General" |
| Output status if safety priority 1 | list | Unchange |
| Output status if safety priority 2 | list | Unchange |
| Forced operation type | list | 1bit |
| Output status if forced operation | list | Unchange |
| Load type | list | Resistive |
| Current correction [-1000..1000] | signedInt -1000…1000 | 0 |
| Power meter function(Wh/kWh) | unsignedInt 0…1 | 0 |
| Object of current measurement | list | Value in mA(DPT 7.012) |
| Add the channel to total current value | unsignedInt 0…1 | 0 |
| Value range for load monitoring | list | 100 mA - 20 A |
| Monitoring lower deviation of load | unsignedInt 0…1 | 0 |
| Behavior at deviating | list | Send no telegram |
| Behavior at not deviating | list | Send no telegram |
| Send falling below cyclical | list | Inactive |
| Counter function | unsignedInt 0…1 | 0 |
| Object of switch and operation hours counter | list | 4 byte Value |
| Switch count if | list | Contact close |
| Hours count if | list | Contact close |
| Send counter value in hours [0..100] | unsignedInt 0…100 | 0 |
| Function of monitoring | unsignedInt 0…1 | 0 |
| Function of forced operation | unsignedInt 0…1 | 0 |
| Function of regular switch | unsignedInt 0…1 | 0 |
| Function of safety operation | unsignedInt 0…1 | 0 |
| Cyclic monitoring control value --in minutes (0...240 minutes) | unsignedInt 0…240 | 60 |
| --in seconds (0...59 seconds) | unsignedInt 0…59 | 0 |
| Valve position during fault | list | Unchange |
| Report fault status | unsignedInt 0…1 | 0 |
| Valve position during forced operation | list | Unchange |
| Time of switch regular in [0..255] | unsignedInt 0…255 | 10 |
| Automatic switch regularly | list | Disable |
| Valve position during safety 1 operation | list | Unchange |
| Valve position during safety 2 operation | list | Unchange |
| Description (max.30 char.) | text | |
| Overwrite scene stored values during download | unsignedInt 0…1 | 1 |
Version history
| Application | App no | Fingerprint | First seen | Size | File |
|---|---|---|---|---|---|
| Switch Actuator with Secure, 4-Fold/3.0 3.0 latest | $0085 | 5E4E | 2026-11-25 | 176 KB | Download |
About this file
This is the official ETS product database for the LAZZEN ERL1604-KNX/G (31001521), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.
More from LAZZEN
- ERL1004-KNX/G 31001516
- ERL1008-KNX/G 31001517
- ERL1016-KNX/G 31001518
- ERL1024-KNX/G 31001519
- ERL1608-KNX/G 31001522
- ERL1612-KNX/G 31001523
- ESC60-TY/G 31001513
- ESC50-KNX/G 31001514
- EDM2001-KNX/G 31001520