| 2 | Output | Release request status present | 1 Bit | 1.2 boolean | CRT |
| 3 | Input | Open door permanently | 1 Bit | 1.1 switch | CW |
| 4 | Input | Release door pulse | 1 Bit | 1.17 trigger | CW |
| 5 | Input | Lock door | 1 Bit | 1.1 switch | CW |
| 6 | Input | Day/night mode | 1 Bit | 1.24 day/night | CW |
| 7 | Output | Day/night mode status | 1 Bit | 1.24 day/night | CRT |
| 8 | Input | Silent mode | 1 Bit | 1.3 enable | CW |
| 9 | Output | Nominal locking state status | 2 Bytes | | CRT |
| 10 | Output | Actual locking state status | 2 Bytes | | CRT |
| 11 | Output | Door lock status | 2 Bytes | | CRT |
| 12 | Output | Door open status | 1 Bit | 1.2 boolean | CRT |
| 13 | Output | Door closed status | 1 Bit | 1.2 boolean | CRT |
| 14 | Output | Position status – lock latch drawn | 1 Bit | 1.2 boolean | CRT |
| 15 | Output | Position status – locking part released | 1 Bit | 1.2 boolean | CRT |
| 16 | Output | Position status – locking part locked | 1 Bit | 1.2 boolean | CRT |
| 17 | Output | Position status – between released and lock latch drawn | 1 Bit | 1.2 boolean | CRT |
| 18 | Output | Position status – key operation possible | 1 Bit | 1.2 boolean | CRT |
| 19 | Input | DRIVE CL control | 1 Byte | | CW |
| 20 | Input | Drive CL – close | 1 Bit | 1.17 trigger | CW |
| 21 | Input | Drive CL – close and lock | 1 Bit | 1.17 trigger | CW |
| 22 | Input | Drive CL – turning position | 1 Bit | 1.17 trigger | CW |
| 23 | Input | Drive CL – complete tilt | 1 Bit | 1.17 trigger | CW |
| 24 | Input | Drive CL – stop or lock | 1 Bit | 1.17 trigger | CW |
| 25 | Input | Drive CL – Gap ventilation night vent | 1 Bit | 1.17 trigger | CW |
| 26 | Input | Drive CL – ventilate 5 minutes | 1 Bit | 1.17 trigger | CW |
| 27 | Input | Drive CL – ventilate 5 minutes and lock | 1 Bit | 1.17 trigger | CW |
| 28 | Input | Drive CL – stop ventilation timer | 1 Bit | 1.17 trigger | CW |
| 29 | Output | Silent mode status | 1 Bit | 1.3 enable | CRT |
| 30 | Output | DRIVE CL status | 1 Byte | | CRT |
| 31 | Output | DRIVE CL status – locked, sash closed | 1 Bit | 1.2 boolean | CRT |
| 32 | Output | DRIVE CL status – locked, sash open | 1 Bit | 1.2 boolean | CRT |
| 33 | Output | DRIVE CL status – turning position, sash closed | 1 Bit | 1.2 boolean | CRT |
| 34 | Output | DRIVE CL status – turning position, sash open | 1 Bit | 1.2 boolean | CRT |
| 35 | Output | DRIVE CL status – night vent | 1 Bit | 1.2 boolean | CRT |
| 36 | Output | DRIVE CL status – stopped | 1 Bit | 1.2 boolean | CRT |
| 37 | Output | DRIVE CL status – tilted | 1 Bit | 1.2 boolean | CRT |
| 38 | Output | DRIVE CL status – closed to, not locked | 1 Bit | 1.2 boolean | CRT |
| 39 | Output | DRIVE CL status – moving | 1 Bit | 1.2 boolean | CRT |
| 40 | Output | DRIVE CL status – stopped due to obstruction | 1 Bit | 1.2 boolean | CRT |
| 41 | Output | DRIVE CL status – moving and can be stopped | 1 Bit | 1.2 boolean | CRT |
| 42 | Output | Error status | 1 Bit | 1.2 boolean | CRT |
| 43 | Output | SIEGENIA bus system communication status | 1 Bit | 1.2 boolean | CRT |
| 44 | Output | "Mode of operation" error status | 1 Bit | 1.2 boolean | CRT |
| 45 | Output | Status – blower performance | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 46 | Output | Status – blower level | 1 Byte | 5.100 fan stage (0..255) | CRT |
| 47 | Output | Status – device state | 1 Bit | 1.3 enable | CRT |
| 49 | Output | Status – control type: standard operation | 1 Bit | 1.3 enable | CRT |
| 50 | Output | Status – control type: automatic mode | 1 Bit | 1.3 enable | CRT |
| 51 | Output | Status – control type: bathroom control | 1 Bit | 1.3 enable | CRT |
| 52 | Output | Status – control type: night ventilation | 1 Bit | 1.3 enable | CRT |
| 53 | Output | Status – air quality | 1 Byte | | CRT |
| 54 | Output | Status – frost protection control | 1 Bit | 1.3 enable | CRT |
| 55 | Output | Status – condensate protection control | 1 Bit | 1.3 enable | CRT |
| 56 | Output | Status – filter change indicator | 1 Bit | 1.2 boolean | CRT |
| 58 | Output | Status – blower mode of operation: supply air | 1 Bit | 1.3 enable | CRT |
| 59 | Output | Status – blower mode of operation: exhaust air | 1 Bit | 1.3 enable | CRT |
| 60 | Output | Status – blower mode of operation: supply/exhaust air | 1 Bit | 1.3 enable | CRT |
| 61 | Output | Status – blower mode of operation: heat recovery | 1 Bit | 1.3 enable | CRT |
| 62 | Output | Exhaust air temperature | 2 Bytes | 9.1 temperature (°C) | CRT |
| 63 | Output | Exhaust air humidity | 2 Bytes | 9.7 humidity (%) | CRT |
| 64 | Output | Exhaust air CO2 value | 2 Bytes | 9.8 parts/million (ppm) | CRT |
| 65 | Input | CO2 value external | 2 Bytes | 9.8 parts/million (ppm) | CW |
| 66 | Input | Temperature value external | 2 Bytes | 9.1 temperature (°C) | CW |
| 67 | Input | Humidity value external | 2 Bytes | 9.7 humidity (%) | CW |
| 68 | Input | Blower performance | 1 Byte | 5.1 percentage (0..100%) | CW |
| 69 | Input | Blower level | 1 Byte | 5.100 fan stage (0..255) | CW |
| 71 | Input | Blower mode of operation: supply air | 1 Bit | 1.3 enable | CW |
| 72 | Input | Blower mode of operation: exhaust air | 1 Bit | 1.3 enable | CW |
| 73 | Input | Blower mode of operation: supply/exhaust air | 1 Bit | 1.3 enable | CW |
| 74 | Input | Blower mode of operation: heat recovery | 1 Bit | 1.3 enable | CW |
| 75 | Input | Device state | 1 Bit | 1.3 enable | CW |
| 77 | Input | Control type: standard operation | 1 Bit | 1.3 enable | CW |
| 78 | Input | Control type: automatic mode | 1 Bit | 1.3 enable | CW |
| 79 | Input | Control type: bathroom control | 1 Bit | 1.3 enable | CW |
| 80 | Input | Control type: night ventilation | 1 Bit | 1.3 enable | CW |
| 81 | Input | Confirm filter replacement | 1 Bit | 1.17 trigger | CW |