KFV (SIEGENIA GRUPPE) 3526984 KNX Gateway

KNX Gateway 3526984

KFV (SIEGENIA GRUPPE) · Order number 3526984 · Gateway

Download .knxprod KNX Gateway A05022 2.2 · 150 KB

Product

ManufacturerKFV (SIEGENIA GRUPPE)
Product nameKNX Gateway
Order number3526984
HardwareKNX Gateway
MediumTwisted Pair
Bus current (mA)18
Rail mountedNo
RegistrationCertified · 2025-05-19
Languagesen-US, cs-CZ, da-DK, el-GR, es-ES, fr-FR, it-IT, nl-NL, pl-PL, ru-RU, sl-SI, de-DE
Catalog entryM-02A8_H-680.20.2F.2F.203526984-0-O000A_HP-A050-22-712F-O000A_CI-3526984-1
Fingerprint712F
SHA-2564954c225f7fcf8e220f9eed57d72c89cec5bf10dc5888588c122d4a54feb6463
First seen2026-11-25
MarketsGermany

Application program: KNX Gateway A05022 2.2

Application number$A050
Version2.2
Mask versionMV-07B0 (System B)
KNX Data SecureYes
Minimum ETS version5.0
Parameters29
Group objects76
Group objects (76)
NoNameFunctionSizeDPTFlags
2OutputRelease request status present1 Bit1.2 booleanCRT
3InputOpen door permanently1 Bit1.1 switchCW
4InputRelease door pulse1 Bit1.17 triggerCW
5InputLock door1 Bit1.1 switchCW
6InputDay/night mode1 Bit1.24 day/nightCW
7OutputDay/night mode status1 Bit1.24 day/nightCRT
8InputSilent mode1 Bit1.3 enableCW
9OutputNominal locking state status2 BytesCRT
10OutputActual locking state status2 BytesCRT
11OutputDoor lock status2 BytesCRT
12OutputDoor open status1 Bit1.2 booleanCRT
13OutputDoor closed status1 Bit1.2 booleanCRT
14OutputPosition status – lock latch drawn1 Bit1.2 booleanCRT
15OutputPosition status – locking part released1 Bit1.2 booleanCRT
16OutputPosition status – locking part locked1 Bit1.2 booleanCRT
17OutputPosition status – between released and lock latch drawn1 Bit1.2 booleanCRT
18OutputPosition status – key operation possible1 Bit1.2 booleanCRT
19InputDRIVE CL control1 ByteCW
20InputDrive CL – close1 Bit1.17 triggerCW
21InputDrive CL – close and lock1 Bit1.17 triggerCW
22InputDrive CL – turning position1 Bit1.17 triggerCW
23InputDrive CL – complete tilt1 Bit1.17 triggerCW
24InputDrive CL – stop or lock1 Bit1.17 triggerCW
25InputDrive CL – Gap ventilation night vent1 Bit1.17 triggerCW
26InputDrive CL – ventilate 5 minutes1 Bit1.17 triggerCW
27InputDrive CL – ventilate 5 minutes and lock1 Bit1.17 triggerCW
28InputDrive CL – stop ventilation timer1 Bit1.17 triggerCW
29OutputSilent mode status1 Bit1.3 enableCRT
30OutputDRIVE CL status1 ByteCRT
31OutputDRIVE CL status – locked, sash closed1 Bit1.2 booleanCRT
32OutputDRIVE CL status – locked, sash open1 Bit1.2 booleanCRT
33OutputDRIVE CL status – turning position, sash closed1 Bit1.2 booleanCRT
34OutputDRIVE CL status – turning position, sash open1 Bit1.2 booleanCRT
35OutputDRIVE CL status – night vent1 Bit1.2 booleanCRT
36OutputDRIVE CL status – stopped1 Bit1.2 booleanCRT
37OutputDRIVE CL status – tilted1 Bit1.2 booleanCRT
38OutputDRIVE CL status – closed to, not locked1 Bit1.2 booleanCRT
39OutputDRIVE CL status – moving1 Bit1.2 booleanCRT
40OutputDRIVE CL status – stopped due to obstruction1 Bit1.2 booleanCRT
41OutputDRIVE CL status – moving and can be stopped1 Bit1.2 booleanCRT
42OutputError status1 Bit1.2 booleanCRT
43OutputSIEGENIA bus system communication status1 Bit1.2 booleanCRT
44Output"Mode of operation" error status1 Bit1.2 booleanCRT
45OutputStatus – blower performance1 Byte5.1 percentage (0..100%)CRT
46OutputStatus – blower level1 Byte5.100 fan stage (0..255)CRT
47OutputStatus – device state1 Bit1.3 enableCRT
49OutputStatus – control type: standard operation1 Bit1.3 enableCRT
50OutputStatus – control type: automatic mode1 Bit1.3 enableCRT
51OutputStatus – control type: bathroom control1 Bit1.3 enableCRT
52OutputStatus – control type: night ventilation1 Bit1.3 enableCRT
53OutputStatus – air quality1 ByteCRT
54OutputStatus – frost protection control1 Bit1.3 enableCRT
55OutputStatus – condensate protection control1 Bit1.3 enableCRT
56OutputStatus – filter change indicator1 Bit1.2 booleanCRT
58OutputStatus – blower mode of operation: supply air1 Bit1.3 enableCRT
59OutputStatus – blower mode of operation: exhaust air1 Bit1.3 enableCRT
60OutputStatus – blower mode of operation: supply/exhaust air1 Bit1.3 enableCRT
61OutputStatus – blower mode of operation: heat recovery1 Bit1.3 enableCRT
62OutputExhaust air temperature2 Bytes9.1 temperature (°C)CRT
63OutputExhaust air humidity2 Bytes9.7 humidity (%)CRT
64OutputExhaust air CO2 value2 Bytes9.8 parts/million (ppm)CRT
65InputCO2 value external2 Bytes9.8 parts/million (ppm)CW
66InputTemperature value external2 Bytes9.1 temperature (°C)CW
67InputHumidity value external2 Bytes9.7 humidity (%)CW
68InputBlower performance1 Byte5.1 percentage (0..100%)CW
69InputBlower level1 Byte5.100 fan stage (0..255)CW
71InputBlower mode of operation: supply air1 Bit1.3 enableCW
72InputBlower mode of operation: exhaust air1 Bit1.3 enableCW
73InputBlower mode of operation: supply/exhaust air1 Bit1.3 enableCW
74InputBlower mode of operation: heat recovery1 Bit1.3 enableCW
75InputDevice state1 Bit1.3 enableCW
77InputControl type: standard operation1 Bit1.3 enableCW
78InputControl type: automatic mode1 Bit1.3 enableCW
79InputControl type: bathroom control1 Bit1.3 enableCW
80InputControl type: night ventilation1 Bit1.3 enableCW
81InputConfirm filter replacement1 Bit1.17 triggerCW
Parameters (25)
ParameterTypeDefault
Mode of operationlistA-opener
_Delay after voltage recovery minutesunsignedInt 0…590
_Delay after voltage recovery secondsunsignedInt 0…5917
Behaviourlisttransmit current statuses
_Gen_Labellist Delay
Transmit temperature valuelistif changed and cyclical
Transmit humidity valuelistif changed and cyclical
Transmit CO2 valuelistif changed and cyclical
Temperature value if changedunsignedInt 1…101
Humidity value if changedunsignedInt 1…502
CO2 if changedunsignedInt 10…20050
Transmit temperature value cyclically hunsignedInt 0…240
Transmit temperature value cyclically minunsignedInt 0…5915
Transmit temperature value cyclically minunsignedInt 0…590
Transmit temperature value cyclically minunsignedInt 3…593
Transmit humidity value cyclically hunsignedInt 0…240
Transmit humidity value cyclically minunsignedInt 0…5915
Transmit humidity value cyclically sunsignedInt 0…590
Transmit humidity value cyclically sunsignedInt 3…593
Transmit CO2 value cyclically hunsignedInt 0…240
Transmit CO2 value cyclically minunsignedInt 0…5915
Transmit CO2 value cyclically sunsignedInt 0…590
Transmit CO2 value cyclically sunsignedInt 3…593
Telegram rate limitunsignedInt 0…10
telegrams per secondunsignedInt 1…155

Version history

ApplicationApp noFingerprintFirst seenSizeFile
KNX Gateway A05022 2.2 latest$A050712F2026-11-25150 KBDownload

About this file

This is the official ETS product database for the KFV (SIEGENIA GRUPPE) KNX Gateway (3526984), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.

More from KFV (SIEGENIA GRUPPE)

All KFV (SIEGENIA GRUPPE) products