Piazza Sense 81471-00

IPAS GmbH · Order number 81471-00 · Push Button

Download .knxprod 81471_PiazzaSense_V1.2.0 1.2 · 193 KB

Product

ManufacturerIPAS GmbH
Product namePiazza Sense
Order number81471-00
HardwarePiazza Sense
MediumTwisted Pair
Bus current (mA)10
Rail mountedNo
RegistrationRegistered · 2022-03-28
Languagesde-DE, en-US
Catalog entryM-00EF_H-81471.2D00-1_HP-8401-12-39ED_CI-81471.2D00-1
Fingerprint39ED
SHA-2564f0faaa2ce2e800d5512167732aa63d7bdeeb57f3893839718bebaa38f00e79f
First seen2026-11-25
Markets59 markets

Application program: 81471_PiazzaSense_V1.2.0 1.2

Application number$8401
Version1.2
Mask versionMV-07B0 (System B)
KNX Data SecureNo
Minimum ETS version5.0
Parameters315
Group objects209
Group objects (209)
NoNameFunctionSizeDPTFlags
1Button PairSwitch, On/Off1 Bit1.1 switchCWT
1Button PairSet Value, Value1 Byte5.5 ratio (0..255)CWT
1Button PairSet Value, Value1 Byte5.1 percentage (0..100%)CWT
1Button PairSetpoint Deviation2 Bytes9.1 temperature (°C)CWT
1Button PairRoom Operation Mode1 Byte20.102 HVAC modeCWT
1Button PairPresence1 Bit1.1 switchCWT
1Button PairFan-Coil, Auto/Manuel1 Bit1.1 switchCWT
1Button LeftSwitch, On1 Bit1.1 switchCWT
1Button LeftSwitch, Off1 Bit1.1 switchCWT
1Button LeftSwitch, Toggle1 Bit1.1 switchCWT
1Button LeftSet Value, Value1 Byte5.5 ratio (0..255)CWT
1Button LeftPresence1 Bit1.1 switchCWT
2Button PairFan-Coil, Rotation Speed1 Byte5.1 percentage (0..100%)CWT
4Keylock left ButtonOn/Off1 Bit1.1 switchCWTU
4KeylockOn/Off1 Bit1.1 switchCWTU
5Button rightSwitch, On1 Bit1.1 switchCWT
5Button RightSwitch, Off1 Bit1.1 switchCWT
5Button RightSwitch, Toggle1 Bit1.1 switchCWT
5Button RightSet Value, Value1 Byte5.5 ratio (0..255)CWT
5Button RightPresence1 Bit1.1 switchCWT
8Keylock right ButtonOn/Off1 Bit1.1 switchCWTU
9TimeTime3 Bytes10.1 time of dayCWTU
9Date and TimeDate/Time8 Bytes19.1 date timeCWTU
10DateDate3 Bytes11.1 dateCWTU
11CO2 ConcentrationValue2 Bytes9.8 parts/million (ppm)CRT
14CO2 Fan-Coil Stage 1 OutputOn/Off1 Bit1.1 switchCRT
15CO2 Fan-Coil Stage 2 OutputOn/Off1 Bit1.1 switchCRT
16CO2 Fan-Coil Stage 3 OutputOn/Off1 Bit1.1 switchCRT
17CO2 Fan-Coil Rotation SpeedValue1 Byte5.1 percentage (0..100%)CRT
20Trafic Light GreenOn/Off1 Bit1.1 switchCRT
21Trafic Light YellowOn/Off1 Bit1.1 switchCRT
22Trafic Light RedOn/Off1 Bit1.1 switchCRT
23RGB CO2 Trafic LightValue3 Bytes232.600 RGB value 3x(0..255)CRT
23Trafic Light RGB, RedValue1 Byte5.5 ratio (0..255)CRT
24Trafic Light RGB, GreenValue1 Byte5.5 ratio (0..255)CRT
25Trafic Light RGB, BlueValue1 Byte5.5 ratio (0..255)CRT
26Actual Value external CO2 SensorValue2 Bytes9.8 parts/million (ppm)CWTU
28Actual Value internal Humidity SensorValue2 Bytes9.7 humidity (%)CRT
29Actual Value external Humidity SensorValue2 Bytes9.7 humidity (%)CWTU
30Actual Value internal Temperature SensorValue2 Bytes9.1 temperature (°C)CRT
31Actual Value external Temperature SensorValue2 Bytes9.1 temperature (°C)CWTU
32Actual Value outside Temperature SensorValue2 Bytes9.1 temperature (°C)CWTU
33Calculated Actual TemperatureValue2 Bytes9.1 temperature (°C)CRT
34Base Setpoint TemperatureValue2 Bytes9.1 temperature (°C)CWTU
35Base Setpoint Temperatur Auto ModeValue2 Bytes9.1 temperature (°C)CWTU
36Setpoint DeviationValue2 Bytes9.1 temperature (°C)CWTU
37Setpoint Deviation Auto ModeValue2 Bytes9.1 temperature (°C)CWTU
38Internal Setpoint TemperatureValue2 Bytes9.1 temperature (°C)CRT
39Room Mode Permanent ProtectionOn/Off1 Bit1.1 switchCWTU
40Controller Switch, On/OffOn/Off1 Bit1.1 switchCWT
41Switch Heating/CoolingHeating/Cooling1 Bit1.100 cooling/heatingCWT
42Window Contact 1Status, Open/Close1 Bit1.9 open/closeCWT
43Window Contact 2Status, Open/Close1 Bit1.9 open/closeCWT
44Window Contact 3Status, Open/Close1 Bit1.9 open/closeCWT
45Window Contact 4Status, Open/Close1 Bit1.9 open/closeCWT
46Presence activateOn/Off1 Bit1.1 switchCWT
47Room Operating ModeValue1 Byte20.102 HVAC modeCWT
48Room Operating Mode StatusValue1 Byte20.102 HVAC modeCRT
49Status Temperature ControllerValue1 Byte5.5 ratio (0..255)CRT
50Status Temperature ControllerValue2 Bytes22.101 RHCC statusCRT
51Control Value 2-Point Controller, HeatingOn/Off1 Bit1.1 switchCRT
51Control Value PI, Heating and CoolingValue, 0..100%1 Byte5.1 percentage (0..100%)CRT
52Control Value PI, HeatingValue, 0..100%1 Byte5.1 percentage (0..100%)CRT
52Control Value PI, HeatingOn/Off1 Bit1.1 switchCRT
53Control Value Sequence 1, HeatingValue, 0..100%1 Byte5.1 percentage (0..100%)CRT
54Control Value Sequence 2, HeatingValue, 0..100%1 Byte5.1 percentage (0..100%)CRT
55Additional Control Value, HeatingOn/ Off1 Bit1.1 switchCRT
56Control Value 2-Point Controller, CoolingOn/Off1 Bit1.1 switchCRT
57Control Value PI, CoolingValue, 0..100%1 Byte5.1 percentage (0..100%)CRT
57Control Value PI, CoolingOn/Off1 Bit1.1 switchCRT
58Control Value Sequence 1, CoolingValue, 0..10%1 Byte5.1 percentage (0..100%)CRT
59Control Value Sequence 2, CoolingValue, 0..100%1 Byte5.1 percentage (0..100%)CRT
60Additional Control Value, CoolingOn/ Off1 Bit1.1 switchCRT
61Fan-Coil Auto ModeOn/Off1 Bit1.1 switchCWT
62Fan-Coil Auto Mode StatusOn/Off1 Bit1.1 switchCRT
63Fan-Coil Rotation Speed InputValue1 Byte5.1 percentage (0..100%)CWT
64Fan-Coil Rotation Speed OutputValue1 Byte5.1 percentage (0..100%)CRT
65Fan-Coil Stage 1 InputOn/Off1 Bit1.1 switchCWT
66Fan-Coil Stage 2 InputOn/Off1 Bit1.1 switchCWT
67Fan-Coil Stage 3 InputOn/Off1 Bit1.1 switchCWT
68Fan-Coil Stage 1 OutputOn/Off1 Bit1.1 switchCRT
69Fan-Coil Stage 2 OutputOn/Off1 Bit1.1 switchCRT
70Fan-Coil Stage 3 OutputOn/Off1 Bit1.1 switchCRT
71Status Comfort ExtensionOn/Off1 Bit1.11 stateCRT
72Alarm 1Active/Inactive1 Bit1.5 alarmCWT
73Alarm 2Active/Inactive1 Bit1.5 alarmCWT
74Alarm 3Active/Inactive1 Bit1.5 alarmCWT
75TextalarmString14 Bytes16.0 Character String (ASCII)CWT
76Dew-Point AlarmActive/ Inactive1 Bit1.5 alarmCWT
77Freeze AlarmActive/ Inactive1 Bit1.5 alarmCRT
78Heat AlarmActive/ Inactive1 Bit1.5 alarmCRT
79CO2 AlarmActive/ Inactive1 Bit1.5 alarmCRT
80Humidity AlarmActive/ Inactive1 Bit1.5 alarmCRT
81Night ModeActive/Inactive1 Bit1.1 switchCWTU
82Screen NumberValue1 Byte5.5 ratio (0..255)CWTU
83Screen 1 Status 1, ValueValue1 Byte5.1 percentage (0..100%)CWTU
83Screen 1 Status 1, TemperatureValue2 Bytes9.1 temperature (°C)CWTU
84Screen 1 Status 2, Inside TemperatureValue2 Bytes9.1 temperature (°C)CWTU
84Screen 1 Status 2, Outside TemperatureValue2 Bytes9.1 temperature (°C)CWTU
84Screen 1 Status 2, Setpoint TemperatureValue2 Bytes9.1 temperature (°C)CWTU
84Screen 1 Status 2, Room ModeValue1 Byte5.5 ratio (0..255)CWTU
84Screen 1 Status 2, PresenceOn/Off1 Bit1.1 switchCWTU
84Screen 1 Status 2, CoolingValue1 Byte5.1 percentage (0..100%)CWTU
84Screen 1 Status 2, HeatingValue1 Byte5.1 percentage (0..100%)CWTU
84Screen 1 Status 2, SwitchSwitch, On/Off1 Bit1.1 switchCWTU
84Screen 1 Status 2, HumidityValue2 Bytes9.7 humidity (%)CWTU
84Screen 1 Status 2, Air QualityValue2 Bytes9.8 parts/million (ppm)CWTU
85Screen 1 Status 3, Inside TemperatureValue2 Bytes9.1 temperature (°C)CWTU
85Screen 1 Status 3, CoolingValue1 Byte5.1 percentage (0..100%)CWTU
85Screen 1 Status 3, PresenceOn/Off1 Bit1.1 switchCWTU
85Screen 1 Status 3, Outside TemperatureValue2 Bytes9.1 temperature (°C)CWTU
85Screen 1 Status 3, Room ModeValue1 Byte5.5 ratio (0..255)CWTU
85Screen 1 Status 3, Setpoint TemperatureValue2 Bytes9.1 temperature (°C)CWTU
85Screen 1 Status 3, HeatingValue1 Byte5.1 percentage (0..100%)CWTU
85Screen 1 Status 3, SwitchSwitch, On/Off1 Bit1.1 switchCWTU
85Screen 1 Status 3, HumidityValue2 Bytes9.7 humidity (%)CWTU
85Screen 1 Status 3, Air QualityValue2 Bytes9.8 parts/million (ppm)CWTU
86Screen 1 Status 4, Room ModeValue1 Byte5.5 ratio (0..255)CWTU
86Screen 1 Status 4, Inside TemperatureValue2 Bytes9.1 temperature (°C)CWTU
86Screen 1 Status 4, Outside TemperatureValue2 Bytes9.1 temperature (°C)CWTU
86Screen 1 Status 4, PresenceOn/Off1 Bit1.1 switchCWTU
86Screen 1 Status 4, SwitchSwitch, On/Off1 Bit1.1 switchCWTU
86Screen 1 Status 4, CoolingValue1 Byte5.1 percentage (0..100%)CWTU
86Screen 1 Status 4, Setpoint TemperatureValue2 Bytes9.1 temperature (°C)CWTU
86Screen 1 Status 4, HeatingValue1 Byte5.1 percentage (0..100%)CWTU
86Screen 1 Status 4, HumidityValue2 Bytes9.7 humidity (%)CWTU
86Screen 1 Status 4, Air QualityValue2 Bytes9.8 parts/million (ppm)CWTU
87Screen 1 Status 5, Setpoint DeviationValue2 Bytes9.2 temperature difference (K)CWTU
87Screen 1 Status 5, TemperatureValue2 Bytes9.1 temperature (°C)CWTU
87Screen 1 Status 5, ValueValue1 Byte5.1 percentage (0..100%)CWTU
88Event ObjectOn/Off1 Bit1.1 switchCWTU
89Screen 2 Status 1, Value Value1 Byte5.1 percentage (0..100%)CWTU
89Screen 2 Status 1, TemperatureValue2 Bytes9.1 temperature (°C)CWTU
89Screen 2 Status 1, ValueValue1 Byte5.3 angle (degrees)CWTU
89Screen 2 Status 1, ValueValue1 Byte5.4 percentage (0..255%)CWTU
89Screen 2 Status 1, ValueValue1 Byte5.5 ratio (0..255)CWTU
90Screen 2 Status 2, ValueValue1 Byte5.1 percentage (0..100%)CWTU
90Screen 2 Status 2, TemperatureValue2 Bytes9.1 temperature (°C)CWTU
90Screen 2 Status 2, ValueValue1 Byte5.3 angle (degrees)CWTU
90Screen 2 Status 2, ValueValue1 Byte5.5 ratio (0..255)CWTU
90Screen 2 Status 2 ValueValue1 Byte5.4 percentage (0..255%)CWTU
91Screen 2 Status 3, ValueValue1 Byte5.4 percentage (0..255%)CWTU
91Screen 2 Status 3, ValueValue1 Byte5.1 percentage (0..100%)CWTU
91Screen 2 Status 3, ValueValue1 Byte5.5 ratio (0..255)CWTU
91Screen 2 Status 3, ValueValue1 Byte5.3 angle (degrees)CWTU
91Screen 2 Status 3, TemperatureValue2 Bytes9.1 temperature (°C)CWTU
92Screen 2 Status 4, ValueValue1 Byte5.4 percentage (0..255%)CWTU
92Screen 2 Status 4, ValueValue1 Byte5.1 percentage (0..100%)CWTU
92Screen 2 Status 4, ValueValue1 Byte5.3 angle (degrees)CWTU
92Screen 2 Status 4, ValueValue1 Byte5.5 ratio (0..255)CWTU
92Screen 2 Status 4, TemperatureValue2 Bytes9.1 temperature (°C)CWTU
93Screen 2 Status 5, TemperatureValue2 Bytes9.1 temperature (°C)CWTU
93Screen 2 Status 5, ValueValue1 Byte5.1 percentage (0..100%)CWTU
93Screen 2 Status 5, ValueValue1 Byte5.3 angle (degrees)CWTU
93Screen 2 Status 5, ValueValue1 Byte5.5 ratio (0..255)CWTU
93Screen 2 Status 5, ValueValue1 Byte5.4 percentage (0..255%)CWTU
94Screen 2 Status 6, TemperatureValue2 Bytes9.1 temperature (°C)CWTU
94Screen 2 Status 6, ValueValue1 Byte5.3 angle (degrees)CWTU
94Screen 2 Status 6, ValueValue1 Byte5.1 percentage (0..100%)CWTU
94Screen 2 Status 6, ValueValue1 Byte5.5 ratio (0..255)CWTU
94Screen 2 Status 6, ValueValue1 Byte5.4 percentage (0..255%)CWTU
95Screen 3 Status 1, ValueValue1 ByteDPT.5CWTU
95Screen 3 Status 1, TextString14 BytesDPT.16CWTU
95Screen 3 Status 1, ValueValue1 ByteDPT.6CWTU
95Screen 3 Status 1, ValueValue2 BytesDPT.7CWTU
95Screen 3 Status 1, ValueValue2 BytesDPT.8CWTU
95Screen 3 Status 1, ValueValue2 BytesDPT.9CWTU
95Screen 3 Status 1, ValueValue4 BytesDPT.12CWTU
95Screen 3 Status 1, ValueValue4 BytesDPT.13CWTU
96Screen 3 Status 2, ValueValue1 ByteDPT.5CWTU
96Screen 3 Status 2, ValueValue1 ByteDPT.6CWTU
96Screen 3 Status 2, ValueValue2 BytesDPT.7CWTU
96Screen 3 Status 2, ValueValue2 BytesDPT.8CWTU
96Screen 3 Status 2, ValueValue2 BytesDPT.9CWTU
96Screen 3 Status 2, ValueValue4 BytesDPT.12CWTU
96Screen 3 Status 2, ValueValue4 BytesDPT.13CWTU
96Screen 3 Status 2, TextString14 BytesDPT.16CWTU
97Screen 3 Status 3, ValueValue1 ByteDPT.5CWTU
97Screen 3 Status 3, TextString14 BytesDPT.16CWTU
97Screen 3 Status 3, ValueValue1 ByteDPT.6CWTU
97Screen 3 Status 3, ValueValue2 BytesDPT.7CWTU
97Screen 3 Status 3, ValueValue2 BytesDPT.8CWTU
97Screen 3 Status 3, ValueValue2 BytesDPT.9CWTU
97Screen 3 Status 3, ValueValue4 BytesDPT.12CWTU
97Screen 3 Status 3, ValueValue4 BytesDPT.13CWTU
98Screen 3 Status 4, TextString14 BytesDPT.16CWTU
98Screen 3 Status 4, ValueValue1 ByteDPT.5CWTU
98Screen 3 Status 4, ValueValue1 ByteDPT.6CWTU
98Screen 3 Status 4, ValueValue2 BytesDPT.7CWTU
98Screen 3 Status, 4 ValueValue2 BytesDPT.8CWTU
98Screen 3 Status 4, ValueValue2 BytesDPT.9CWTU
98Screen 3 Status 4, ValueValue4 BytesDPT.12CWTU
98Screen 3 Status 4, ValueValue4 BytesDPT.13CWTU
99Screen 3 Status 5, TextString14 BytesDPT.16CWTU
99Screen 3 Status 5, ValueValue1 ByteDPT.5CWTU
99Screen 3 Status 5, ValueValue1 ByteDPT.6CWTU
99Screen 3 Status 5, ValueValue2 BytesDPT.7CWTU
99Screen 3 Status 5, ValueValue2 BytesDPT.8CWTU
99Screen 3 Status 5, ValueValue2 BytesDPT.9CWTU
99Screen 3 Status 5, ValueValue4 BytesDPT.12CWTU
99Screen 3 Status 5, ValueValue4 BytesDPT.13CWTU
100Screen 3 Status 6, TextString14 BytesDPT.16CWTU
100Screen 3 Status 6, ValueValue1 ByteDPT.5CWTU
100Screen 3 Status 6, ValueValue1 ByteDPT.6CWTU
100Screen 3 Status 6, ValueValue2 BytesDPT.7CWTU
100Screen 3 Status 6, ValueValue2 BytesDPT.8CWTU
100Screen 3 Status 6, ValueValue2 BytesDPT.9CWTU
100Screen 3 Status 6, ValueValue4 BytesDPT.12CWTU
100Screen 3 Status 6, ValueValue4 BytesDPT.13CWTU
Parameters (274)
ParameterTypeDefault
Cycle Time for Freeze Alarm sendinglist10 Minutes
Maximum Output Value for Heating ValveunsignedInt 50…100100
Minimum Output Value for Cooling ValveunsignedInt 0…500
Ratio between Internal and External Temperature Valuelist50 % Internal - 50 % External
Cycle Time for Cyclical Sending actual Temperaturelist10 Minutes
Increase/Reduction if Operation Mode Energy-Savinglist4 K
Setpoint at Cooling is depending from outside TemperaturelistNo
Object Function Alarm 1listNormal
Stepsize Setpoint Deviationlist1 K
Deadzone between Heating and Coolinglist0.5 K
Fan-Coil Stage 3 Output 0..255=>0..100%, 100% = 255unsignedInt 0…255255
Deviation for automatical sending Control Value Coolinglist5 %
Outside Temperature Sensor existinglistNo
Offset for external Temperature Sensor (Value/10, i.e. 12 =>1.2 K)signedInt -50…500
Object Function Alarm 2listNormal
Deviation of Setpointlist+/- 3 Steps
Threshold Heat Alarmlist40 °C
Sequence 2 starts on Value HeatingunsignedInt 5…10050
Integration Time Heatinglist30 Minutes
General Alarm 1 existinglistYes
Object Function Alarm 3listNormal
General Text at AlarmtextAttention
Text on display at keylock functiontextKeylock
Type of Control Value Output Heatinglist1 Byte
Cycletime for cyclical sending Control Value Coolinglist10 Minutes
Buzzer deactivate after SecondsunsignedInt 0…18010
General Alarm 2 existinglistYes
Text on display if keylock activatetextactivate
Proportional Band Heatinglist5 K
Room Operation Mode after ResetlistPre-Comfort
General Alarm 3 existinglistYes
Date FormatlistDD.MM.YY
Show Alarms on DisplaylistYes
Output Cooling always ON from [Value in %]unsignedInt 50…10098
Alarm Function availablelistYes
Display Brightness by ECO Modelist30%
Fan-Coil Stage 1 Output 0..255=>0..100%, 33% = 85unsignedInt 0…25585
Wake up LEDs if a Button pressedlistfor 10 s
Text Message on Display at Heat AlarmtextHeat Alarm
External KNX Temperature Sensor availablelistNo
Status Read Request after Resetlist1 Second after Bus Reset
Common Object for Heating and CoolinglistNo
Text Message on Display at Dew-Point AlarmtextDew-Point
Invert Control Value HeatinglistNo
Number of Fan-Coil Stageslist3 Stages (0/33/66/100%)
Controller Method HeatinglistPI Controller
Fan-Coil Stage 1 starts from 0..255=>0..100%, 0.4% = 1unsignedInt 0…2551
Scaling 100% tounsignedInt 50…100100
Cycle Time for sending Output Valuelist10 Minutes
Hysteresis 2-Point Controllerlist0.2 K
Cycle Time for Sensor Request outside Temperaturelist5 Minutes
Minimum Output Value for Heating ValveunsignedInt 0…500
Fan-Coil Stage 2 starts from 0..255=>0..100%, 34% = 86unsignedInt 0…25586
Operating Mode of DisplaylistNormal Operation
Base Setpoint after Busresetlist21 °C
Function of Automatic ObjectlistNormal
Maximum Output value for Cooling ValveunsignedInt 50…100100
Fan-Coil Stage 3 starts from 0..255=>0..100%, 67% = 171unsignedInt 0…255171
Deviation for automatical sending Control Value Sequence 2 Coolinglist5 %
Switch off Traffic Light in Night ModelistYes
Output Heating always ON from [Value in %]unsignedInt 50…10098
Sequence 2 starts on Value CoolingunsignedInt 5…10050
Number of Window ContactslistNo Window Contacts
Increase/Reduction if Operation Mode Pre-Comfortlist2 K
Offset for internal Temperature Sensor (Value/10, i.e. 12 =>1.2 K)signedInt -50…500
Text Message on Display at Freeze AlarmtextFreeze Alarm
Threshold Freeze Alarmlist5 °C
Deviation for automatical sending Control Value Heatinglist5 %
Integration Time Coolinglist30 Minutes
Cycle Time for Sensor Request external Temperaturelist5 Minutes
Time Formatlist24h
Freeze Alarm existinglistYes
Fan-Coil Stage 2 Output 0..255=>0..100%, 66% = 170unsignedInt 0…255170
Proportional Band Coolinglist5 K
Output Cooling always OFF from [Value in %]unsignedInt 0…502
Fan-Coil Automatic Mode after BusresetlistYes
Type of Controlvalue Output Coolinglist1 Byte
Cycle Time for cyclical sending Control Value Heatinglist10 Minutes
Beep if button pressing activatelistYes
Change Heating/Cooling is adjusted by external ObjectlistNo
Text Alarm existinglistYes
Text Message on Display at Alarm 1textAlarm 1
Setpoint Heat-Protection, Coolinglist32 °C
Object Type for Date and Timelist2 separate Objects (2 x 3 Byte)
Controller ModelistController, Heating/Cooling
Reaction Time on Window opening in SecondsunsignedInt 0…18030
Status Object for Comfort Extension existinglistNo
Display Brightness by Normal Operatinglist70%
Text Message on Display at Alarm 2textAlarm 2
Dew-Point Alarm existinglistYes
Display Brightness by Night ModelistDisplay Off
Delay between individual Read Requestslist200 msec
Invert Window ContactslistNo
Reset Alarm via same ObjectlistYes
Text Message on Display at Alarm 3textAlarm 3
Controller Mode after ResetlistHeating
Setpoint Freeze-Protection, Heatinglist5°C
Deviation for automatical sending Control Value Sequenze 2 Heatinglist5 %
Offset for outside Temperature Sensor (Value/10, i.e. 12 =>1.2 K)signedInt -50…500
Send actual Temperature when Change bylist+/- 0.3 K
Invert Controlvalue CoolinglistNo
Behaviour after ResetlistUse ETS Parameter below
Heat Alarm existinglistYes
Controller Method CoolinglistPI Controller
Cycle Time for Heat Alarm sendinglist10 Minutes
Buzzer activate at AlarmlistYes
Waking Up the Displaylistfor 10 s
Duration of Comfort Extensionlist30 Minutes
Output Heating always OFF from [Value in %]unsignedInt 0…502
Screen Switching VariantlistManually
Automatically Jump Back to the Main ScreenlistYes
Delay for Jump Backlist3 Seconds
Screen 1 activatelistYes
Screen 2 activatelistYes
Screen 3 activatelistYes
Invert Function of ValvelistNo
Fan-Coil Stage on Fan Startup ( for 3 Seconds)listStage 1
Fan-Coil Stage 1 Output 0..255=>0..100%, 100% = 255unsignedInt 0…25585
Fan-Coil Stage 2 starts from 0..255=>0..100%, 50% = 128unsignedInt 0…25586
Fan-Coil Stage 2 Output 0..255=>0..100%, 100% = 255unsignedInt 0…255170
Fan-Coil Stage 1 Output 0..255=>0..100%, 49% = 127unsignedInt 0…25585
Periode Length for Switching Output Heatinglist10 Minutes
Periode Length for Switching Output Coolinglist10 Minutes
Deviation for automatical sending Control Value Heating Sequenze 1list5 %
Deviation for automatical sending Control Value Cooling Sequence 1list5 %
Fan-Coil Operation ModelistNo Fan Coil Operation
Text on display if keylock deactivatetextdeactivate
Type of Status 1listTime and Date
Type of Status 2listAir Quality Icon + Value
Type of Status 3listInside Temperature Icon + Value
Type of Status 4listHumidity Icon + Value
Type of Status 5listSetpoint Deviation
Type of Status 1listText + Value 1 Byte
Type of Status 2listText + Value 1 Byte
Type of Status 3listText + Value 1 Byte
Type of Status 4listText + Temperature
Type of Status 5listText + Temperature
Type of Status 6listSetpoint Deviation
Type of Status 1listText
Type of Status 2listText
Type of Status 3listText
Type of Status 4listText
Type of Status 5listText
Type of Status 6listText
TestlistScreen 3
Main Screen NumberlistScreen 1
Main Screen NumberlistScreen 2
Main screen calculationunsignedInt 0…2553
Text of Status 1textHeating
Text of Status 5text0
Text of Status 2text0
Text of Status 3text0
Text of Status 4text0
Text of Status 6text0
Text of Status 1textStatus 1
Text of Status 2textStatus 2
Text of Status 3textStatus 3
Text of Status 4textStatus 4
Text of Status 5textStatus 5
Text of Status 6textStatus 6
Type of ValuelistValue (0..100%)
Unit Texttext%
Showing the UnitlistNo
Usage for internal StatuslistYes
Typ of the IconlistBulb
Inside Temperature Iconpicture
Outside Temperature Iconpicture
Setpoint Temperature Iconpicture
Heating Valve Iconpicture
Cooling Valve Iconpicture
Bulb on at Value 1picture
Bulb off at Value 0picture
Socket on at Value 1picture
Speaker off at Value 0picture
Socket off at Value 0picture
Speaker on at Value 1picture
Lock open at Value 0picture
Lock close at Value 1picture
Bulb on at Value 0picture
Bulb off at Value 1picture
Socket on at Value 0picture
Speaker off at Value 1picture
Socket off at Value 1picture
Lock open at Value 1picture
Speaker on at Value 0picture
Lock close at Value 0picture
Main Screen 1listScreen 1
Main Screen 2listScreen 2
Main Screen 3listScreen 3
Cycle Time for Automatic Screen Switchinglist3 Seconds
Additional Control Value Output availablelistNo
Offset to Setpoint Temperaturelist2 K
Difference to outside Temperaturelist8 K
Fan_Coil_Mode_CalculationlistNo
Reset Setpoint Deviation on Room Mode ChangelistNo
Behaviour after ResetlistSet Setpoint Deviation to 0 K
Invert Additional Control Value OutputlistNo
Fan-Coil-Stages-CalculationunsignedInt 0…2550
Fan-Coil-Int-ExtunsignedInt 0…2550
Type of Valuelist1 Byte unsigned Value
Source for TextlistShow Text from ETS Parameter below
Sourse for TextlistShow Text from ETS Parameter below
Altitude above Sea Level (Value*1m)unsignedInt 0…20000
Cycle Time for cyclical sending actual CO2 Valuelist10 Minutes
Send actual CO2 Value when Change bylist+/- 50 ppm
CO2 Traffic Light availablelistYes
Traffic Light Threshold 1 (Value in ppm)unsignedInt 400…40000700
Traffic Light Threshold 2 (Value in ppm)unsignedInt 400…400001200
External CO2 Traffic Light availablelistNo
IAQ Fan-Coil AvailablelistNo
Fan-Coil Stage 1 Start from (Value in ppm)unsignedInt 400…40000600
Fan-Coil Stage 2 Start from (Value in ppm)unsignedInt 400…40000800
Fan-Coil Stage 3 Start from (Value in ppm)unsignedInt 400…400001000
Function of ButtonslistSetpoint Deviation
Direction of ButtonslistLeft: Off/ Down, Right: On/Up
Show Status on DisplaylistYes
Function Nametext0
CO2 Alarm existinglistYes
Threshold CO2 Alarm (in ppm)unsignedInt 0…655351400
Cycletime for CO2 Alarm sendinglist10 Minutes
Text Message on Display at CO2 AlarmtextCO2 Alarm
Source for internal Temperature MeasurementlistInternal Sensor
Show Status aslistText
Text at Value 0textOff
Text at Value 1textOn
Type of the IconlistBulb
Value if pressing left ButtonunsignedInt 0…2550
Value if pressing right ButtonunsignedInt 0…2550
2. Value if pressing left ButtonunsignedInt 0…2550
2. Value if pressing right ButtonunsignedInt 0…2550
Step Size Value if pressing Buttonlist10 %
Percentage Barpicture
Step Size on Button presslist1 K
Number of available Setpoint Stepslist+/- 3 Steps
Usage Internal for Room Temperature ControllerlistYes
Setpoint Deviation as absolute ValuelistNo
Possible Room Operation ModeslistAll possible Operation Modes
Comfort Modepicture
Pre-Comfort Modepicture
Economy Modepicture
Protection Modepicture
Presencepicture
Absencepicture
Waking up Display via Event ObjectlistNo
Fan-Coil Stage 2 Output 0..255=>0..100%, 66% = 170unsignedInt 0…255170
Fan-Coil Stagepicture
Object for Keylock availablelistNo
Function of left ButtonlistToggle
Function of right ButtonlistToggle
1. Value if pressing left ButtonunsignedInt 0…2550
Text at Value 1textOff
Text at Value 1text0
Text at Value 0text0
1. Value if pressing right ButtonunsignedInt 0…2550
Humidity Alarm existinglistYes
Threshold Humidity Alarm (in %)unsignedInt 0…10090
Cycle Time for Humidity Alarm sendinglist10 Minutes
Text Message on Display at Humidity AlarmtextHumidity Alarm
RGB Object for CO2 Traffic Light AvailablelistNo
Object Type RGB Traffic Lightlist3 Byte combined Object
External CO2 Sensor availablelistNo
Cycle Time for Sensor Request external CO2 Sensorlist5 Minutes
Ratio between internal and external CO2 Sensorlist50 % Internal - 50 % External
Offset for internal Humidity Sensor (in %)signedInt -100…1000
Cycle Time for cyclical sending actual Humidity Valuelist5 Minutes
Send actual Humidity Value when Change bylist10 %
External Humidity Sensor availablelistNo
Offset for external Humidity Sensor (in %)signedInt -100…1000
Cycle Time for Sensor Request external Humidity Sensorlist10 Minutes
Ratio between internal and external Humidity Sensorlist50 % Internal - 50 % External
Air Qualitypicture
Humiditypicture
Keylock CalculationlistNo
Waking up LED vie Event ObjectlistYes

Version history

ApplicationApp noFingerprintFirst seenSizeFile
81471_PiazzaSense_V1.2.0 1.2 latest$840139ED2026-11-25193 KBDownload

About this file

This is the official ETS product database for the IPAS GmbH Piazza Sense (81471-00), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.